Questions_and_Answers_2__for_H92222-17-R-0011.pdf

PDF 66 KB Posted

Attached to
Suppress Upper Receiver Group
Solicitation number
H92222-17-R-0011
Issued by

View the file

Other files

File Type Posted
Questions_and_Answers_5_for_H92222-17-R-0011.pdf PDF
Questions_and_Answers_4_for_H92222-17-R-0011.pdf PDF
DS-JXNN-C08-1621A_-_Ball,_Carbine,_Barrier,_MK318_MOD0.pdf PDF
SURG_Attachment_05_Go_No_Go_Matrix_170530.pdf PDF
Questions_and_Answers_3_for_H92222-17-R-0011.pdf PDF
NAVSEAINST_SS800-AG-MAN-010P-9290.pdf PDF
DS-JXNN-C08-1621_Rev_A_MK318_MOD1_Ammunition.pdf PDF
SURG_Attachment_02_Phase_Two_Testing__170224.pdf PDF
SURG_Attachment_01_PerfSpec___1700530.pdf PDF
ASTM_D3951_Standard_Practice_for_Commercial_Packaging.pdf PDF
DS-4083-C02-1273_Rev_A_-_MK262_MOD1_Ammunition.pdf PDF
ASTM_E1444__E1444M_Standard_Practice_for_Magnetic_Particle_Testing.pdf PDF
HS-4083-C01-1240_Rev_C_Frangible,_MK311_MOD_0.pdf PDF
SURG_Attachment_06_Past_Performance_Info_Sheet___170210.pdf PDF
HS-JXNN-C11-0008_Rev_1_MK_255_MOD_1_Reduced_Ricochet_Limited_Penetration.pdf PDF
ASTM_E1417__E1417M_Standard_Practice_for_Liquid_Penetrant_Testing_.pdf PDF
NATO_STANAG_4172ed2_5.56mm_Ammunition_(Linked_or_Otherwise).pdf PDF
HS-4083-C03-1351_Rev_1_5.56mm_Dim_Tracer_Performance_Specification.pdf PDF
H92222-17-R-0011_Amendment_03.pdf PDF
NAVSEAINST_System_Certification_Procedures_and_Criteria_Manual_for_Deep_Submergence_Systems.pdf PDF
SURG_Attachment_03_PhaseThreePrecedence__170530.pdf PDF
H92222-17-R-0011_Amendment_0001.pdf PDF
SURG_Exhibit_B_Provisioning_Parts_List.xls XLS spreadsheet
SURG_Exhibit_A_CDRLS_A001-A008.pdf PDF
SURG_Attachment_06_Past_Performance_Info_Sheet.pdf PDF
SURG_Attachment_03_PhaseThreePrecedence.pdf PDF
H92222-17-R-0011__SOLICITATION.pdf PDF
SURG_Attachment_02_Phase_Two_Testing.pdf PDF
SURG_Attachment_04_Flash_Test_Report.pdf PDF
SURG_Attachment_01_PerfSpec___170224_Parker_Comments.pdf PDF
SURG_Attachment_05_Go_No_Go_Matrix.pdf PDF
Additional_Point_of_Contact_H92222-17-R-0011__SURG.pdf PDF
Additional_Point_of_Contact_H92222-17-R-0011__SURG.pdf PDF
Questions_and_Answers_for_H92222-17-R-0011.pdf PDF
SURG_Synopsis_20161118.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers for H92222-17-R-0011 SURG As of 15 Feb 17

Below Question is from the original Questions and Answers

165. Orientation of the microphones during sound pressure level testing? a. The new microphones purchased for use on SURG 2.0 testing (4944A Delta Tron Pressure Field .25" Mic, 1.00V/Pa) mics are pressure field type mics and are designed to be pointed directly at the sound source. Based on the weapon platform and for consistency across each vendor the mics will be pointed at the muzzle of the weapon during any sound pressure level measurements. Please note that this was incorrectly demonstrated at SURG industry day at NSWC Crane. The microphone should have been aimed at the muzzle of the MK18 MOD1 used for demonstration

The UPDATED INFORMATION TO THE ABOVE QUESTION AS OF 15 FEBRUARY 2017

Q165 UPDATED: Orientation of the microphones during sound pressure level testing?

A165 UPDATED: The new microphones purchased for use on SURG 2.0 testing (4944A Delta Tron Pressure Field .25" Mic, 1.00V/Pa) microphones are pressure field type microphones and are designed to be pointed directly at the sound source.

That said the design of the test is to replicate the human ear (shooters ear position). To best replicate the analog of the human ear a pressure field microphone needs to be orientated perpendicular to the source of sound. To ensure that the orientation is consistently 90° to the source, the microphone will be positioned such that the major axis of the microphone is normal (90°) to the ground with the mic end pointed upwards.