Amendment_05_-_905_DB_RFP_6.12.15.docx
DOCX document 46 KB Posted
- Solicitation number
- GS-10P-15-LT-R-9000
About this file
Amendment 05 - 905 DB RFP 6.12.15
View the file
Other files
Show 40 more
Latest 50 of 58 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MODIFICATION SCHEDULE
| Item No. |
| Supplies/Services |
| Quantity |
| Unit |
| Unit Price |
| Amount |
| AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT |
| 1. Contract ID Code |
| Page of Pages |
| 1 |
| 4 |
| 2. Amendment/Modification No. |
| 3. Effective Date |
| 4. Requisition/Purchase Req. No. |
| 5. Project No. (if applicable) |
| 05 |
| June 12 2015 |
6. Issued By
| 7. Administered By (If other than Item 6) |
| Code |
| GSA PBS Design & Construction Division |
| See Block 6 |
400 15th St SW Auburn, WA 98001 Richard Risso, 253-931-7309
| 8. Name and Address of Contractor (No., Street, County, and Zip Code) |
| (X) |
| 9A. Amendment of Solicitation No. |
| X |
| GS-10P-15-LT-R-9000 |
9B. Date (See Item 11)
May 5 , 2015
10A. Modification of Contract/Order No.
10B. Date (See Item 13)
| Code |
| Facility Code |
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
| X |
| The above numbered solicitation is amended as set forth in item 14. The hour and date specified for receipt of Offers |
| X |
| is extended |
is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
| (a) By completing items 8 and 15, and returning |
| 1 |
| copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer |
submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDG-
MENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT
IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. Accounting and Appropriation Data (if required)
1. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACT/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
| (x) |
| A. This change order is issued pursuant to: (Specify authority) The changes set forth in item 14 are made in the Contract Order No. in item 10A. |
B. The above numbered Contract/Order is modified to reflect the administrative changes (such as changes in paying office, appropriation date, etc.)
Set fourth item 14, pursuant to the authority of FAR 43.103 (b)
C. This supplemental agreement is entered into pursuant to authority of:
D. Other (Specify type of modification and authority)
| E. IMPORTANT: Contractor |
| is not, |
is required to sign this document and return 3 copies to the issuing office.
14. Description of Amendment/Modification (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
BPA (905 BLDG) OUTSIDE AIR INTAKE RELOCATION &
ELEVATOR DESIGN BUILD MODERNIZATION
The purpose of this amendment is to respond to submitted questions.
4. There is not sufficient information to determine the role of the Design Build Manager. Please specify GSA expectations for this person and how their role may differ from that of a Project Manager.
The Design Build Manager role is geared around pre-construction services, while the Construction Project Manager role is mainly post design, construction. For efficiency, GSA agrees to remove the requirement for the Design Build Manager under Key Personnel; however, the requirement for the Construction Project Manager will increase from 5 years to 10 years to compensate for the lost level of experience in project management. The Solicitation will be modified to make these changes as depicted below and attached to this amendment.
1. Design Build Manager (DBM) – The DBM should have a minimum of ten (10) years experience in the field of construction management. Personnel with direct construction management experience as gained in a project manager or superintendent role in the construction industry may be rated more favorably. A four-year (i.e. B.S.) degree in Construction Management, Engineering or related field OR a highly experienced individual in the construction field with a minimum of fifteen (15) years Construction Management experience in work of comparative size, value and technical complexity to the project in this solicitation is required. Clearly state in your proposal the number of years experience that this proposed team member has served as a DBM.
The DBM shall have experience in the interdisciplinary management and coordination of the numerous disciplines and trades surrounding large design-build facility construction projects with a magnitude of ($5M - $7M and 700,000 – 800,000 SF). High rise facilities experience will be rated more favorably.
The DBM shall have experience with computer based scheduling software and have the ability to interpret schedules generated from this system and shall demonstrate experience with whole-project cost/budget control.
The DBM shall demonstrate experience inclusive of knowledge and management of all aspects of design and construction phases within a design build project. Demonstrated experience managing both the design and construction aspects of design build projects of similar size and technical complexity in occupied facilities. (Amendment 5).
2. Construction Project Manager (CPM) – The CPM shall be an employee of the prime contractor and have a minimum of ten (10) five (5) (Amendment 5) years’ experience in the field of construction management of construction projects of similar size and scope to that of this Project. Personnel with direct construction management experience as gained in a project manager or superintendent role in the construction industry may be rated more favorably. Four-year (i.e. B.S.) degrees in Construction Management, Engineering and/or Industry/Professional Certifications are desirable and may be rated more favorably. Clearly state in your proposal the number of years experience that this proposed team member has served as a CPM.
Additionally, the proposed CPM shall demonstrate the following requisite experience:
i. The CPM shall have experience in the interdisciplinary management and coordination of the numerous disciplines and trades surrounding large design-build facility construction projects with a magnitude of ($5M - $7M and 700,000 – 800,000 SF). High rise facilities experience will be rated more favorably.
ii. The CPM shall have experience with computer based scheduling software and have the ability to interpret schedules generated from this system. In addition to scheduling software, demonstrated experience with electronic project management applications inclusive of various modules such as budget tracking,
iii. Schedule of Values (SOV) input, Request for Information (RFI) submittal/response functionality, etc. may be rated more favorably.
iv. The CPM shall have field experience coordinating day-to-day site issues relating to materials, labor, and equipment utilization on large commercial projects. Demonstrated experience inclusive of knowledge and management of all aspects of design and construction phases within a design build project, as well as demonstrated experience managing projects of similar size and technical complexity in occupied facilities may be rated more favorably.
5. We cannot find the following drawings of existing conditions. Would it be possible to make them available for our analysis?
a. 5-1 through 5-4 (Building Sections)
b. 7 S-41 through 7 S-50 (P.T. Schedules / Concrete Sections and Details)
c. 7 S-63 through 7 S-68 (Cladding Sections and Details
Drawings obtained and attached to this amendment.
6. Page 2 of the Lerch Bates report mentions work needing to be done on the hydraulic elevator installed in 1987. However, your bid form does not list it for any pricing. Do you want this scope included? If so, will you be re-issuing the bid form to include this work?
The hydraulic elevator is included in the project. No need to amend Exhibit 1 - Price and Services Schedule. Please include pricing for the hydraulic elevator within the CLINS 0002 & 0004, which are already identified for elevator design and construction. GSA expects to see breakout costs in your CSI Level 3 detail as required under Exhibit 1.
7. We have concerns with the project schedule which includes preconstruction as it relates to the elevator scope of work. We believe there needs to be additional time allotted for the elevator fabrication process, which includes the review and acceptance of submittals by the owner before final submission to the elevator company.
We are also assuming no more than 2 elevators can be shut down at one time. Based on this assumption, we anticipate 13 weeks per 2 cars which equals a total [elevator] construction duration of 455 calendar days. Without the ability to shut down additional elevators and the inability to work additional shifts leaves us without any avenue to expedite this schedule.
The estimated schedule and performance period for construction will be extended a total of 290 calendar days as follows: 140 calendar days for fabrication, 60 additional calendar days for owner review, approval and preconstruction coordination of submittals and 90 additional days of construction time based on feedback from industry. Total estimated construction time is changed to 655 calendar days from 365 calendar days, a total increase of 290 calendar days.
8. Please clarify the intent "providing a lockable disconnect switch as close as possible to the door jam".
Currently the elevator switchboard appears to be as close as possible to the door strike without impeding the door operability. The existing switchbaord disconnect handles appear to be an older style that has lock off capabilities by pulling a tab out to install a lock. Once the lock is installed on the pull out tab then the disconnect handle is no longer operable. If the intent is to provide (1) single disconnect for all elevator controllers to simultaneously shut down then please confirm that the existing switchboard would need to be entirely replaced with a main breaker switch board that has shut trip capabilities on the main breaker.
Exhibit 5 905 BPA DB SOW 6.12.15 – Amendment 05, recinds Paragraph 4 ADDENDUM in its entirety since this scope was recently discovered complete and therefore not required after release of the RFP.
ADDENDUM (Amendment 03, 06.03.15) (Amendment 05)
In 2004 a third party contractor identified the lack of a main disconnect switch in the elevator mechanical room, as prescribx sdfd by NEC 2002 Section 620.51 (C)(1)(2).
In the elevator machine room, provide a lockable disconnect switch (safety switch, general duty 240V, 3-pole NEMA-1, fusible, 30A) to be located directly next to the entrance door, so that it is readily accessible in an emergency situation.
Locate the switch so that it is located within sight of the motor controller as required by NEC 2002 Section 620.51 (C)(1)(2).
See attached VFA Facility Assessment Report 2004 Elevator Main Excerpt
The time set for receipt of proposals is extended to Monday, 29 June 2015 at 1:00PM PST.
All other terms and conditions remain unchanged.
Attachments:
1. GS-10P-15-LT-R-9000 DB SOLICITATION 6.12.15 Amendment 05
2. Exhibit 5 905 BPA DB SOW 6.12.15 - Amendment 05
3. BPA Structural Files 6.12.15 – Amendment 05
4. BPA Draft Schedule 6.15.15 – Amendment 05
| SF30 Continuation of Block Narrative |
| Page |
| 4 |
| of |
| 4 |
Except as provided herein, all terms and conditions of the document referenced in item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
| 15A. Name and Title of Signer (Type or Print) |
| 16A. Name and title of Contracting Officer (Type or Print) |
| 15B. Contractor/Offeror |
| 15C. Date Signed |
| 16B. United States of America |
(Signature of Contracting Officer) 16C. Date Signed
_____________________________________________(Signature of person authorized to sign)
| NSN 7540-01-152-8070 |
| 30-105 |
STANDARD FORM 30 (REV. 10-83)
PREVIOUS EDITIONS UNUSABLE
Prescribed by GSA FAR (48 CFR) 53.243
File details come from the government source that posted it. Updated .