General Services Administration Building
Chicago, IL
Asbestos-Containing Material and Lead-Based Paint Survey Summary Report
Robert A. Grant Federal Building and U.S. Courthouse 204 South Main Street South Bend, Indiana
Prepared By
Carnow, Conibear & Assoc., Ltd.
300 West Adams Street, Suite 1200 Chicago, IL 60606
Table of Contents
Executive Summary……………………………………………………
1.0 Introduction ……………………………………………………
2.0 Building Description ……………………………………………
3.0 Asbestos Survey Protocol
3.1 Asbestos Survey…………………………………………….. 4
3.2 Asbestos Analysis…………………………………………… 5
3.3 Asbestos Survey Results……………………………………. 5
4.0 Lead Paint Survey
4.1 Lead Paint Survey ………………………………………….. 7
4.2 Lead Paint Analysis ………………………………………… 7
4.2 Lead Paint Survey Results………………………………….. 7
5.0 Conclusions and Recommendations
6.0 Study Limitations………………………………………………….. 9
7.0 Signature and Quality Control Page
Table 1 - Asbestos Inventory and Analytical Summary
Table 2 - Asbestos Containing Materials
Table 3 - Lead Paint Inventory Summary
Attachments
Attachment A - Facility Maps: Locations of ACM
Attachment B - Asbestos and Lead Laboratory Analytical Reports
Attachment C - Photographs
Attachment D - Field Notes
Attachment E - Cost Estimate
ACM and LBP Survey Summary Report Page 1 October 2007 Robert A. Grant Federal Building and US Courthouse
EXECUTIVE SUMMARY
Carnow, Conibear & Assoc., Ltd. conducted an asbestos containing material and lead-based paint survey at the Robert A. Grant Federal Building and U.S. Courthouse located at 204 South Main Street, South Bend, Indiana. The building was inspected by licensed and certified asbestos building inspector Heather Eckard on August 21, 2007. The asbestos survey was conducted in accordance with 29 CFR 1926.1101, 40 CFR Part 61, and applicable state and local requirements.
The asbestos containing material portion of the survey included identifying suspect friable and non-friable asbestos containing building materials (ACBM) and assessing the friability, assessing the current condition and potential for future disturbance, quantifying the suspect asbestos containing materials, and rating the overall condition of the materials. A total of thirty-six (36) bulk samples were collected from the building interior. A total of thirty-six (36) samples were analyzed for asbestos content by Davis Environmental Labs, Inc., located in Evanston, Illinois.
Asbestos was found in the following materials:
• Aircell Pipe Insulation
• Fittings Associated with Aircell Pipe Insulation
• Paperwrap Pipe Insulation
• Fittings Associated with Paperwrap Pipe Insulation
The following materials were not tested at the time of the inspection and should be assumed to contain asbestos until they can be tested.
• Vibration Damper
• Roofing Materials
• Elevator Outer Shell Materials
Based upon the results of lead-based paint (LBP) testing, LBP was identified on the following components:
• Brown on Exterior Wood Window Sill
• Beige on Plaster Wall
ACM and LBP Survey Summary Report Page 2 October 2007
1.0 INTRODUCTION
On behalf of the General Service Administration (GSA), Carnow, Conibear & Assoc., Ltd. (CARNOW CONIBEAR) conducted a survey of suspect asbestos containing materials (ACM) and lead-based paint (LBP) at the Robert A. Grant Federal Building and US Courthouse located at 204 South Main Street in South Bend, Indiana. This project was conducted in accordance with CARNOW CONIBEAR’s proposal to the GSA dated June 26, 2007.
The asbestos containing material portion of the project included conducting an AHERA-type building inspection for ACM and preparing an asbestos management plan to fulfill asbestos requirements as specified in 29 CFR Part 1910.1001 (OSHA Asbestos Standard) and the requirements of the Program Development Study (PDS) task for the GSA Prospectus Work.
Heather Eckard, EPA certified Asbestos Building Inspector (IDPH license # 100-10397), performed the inspection and collected the bulk samples of the friable and non-friable suspect ACM. The inspection team and GSA field manager, Mr. Phil Ramos, were escorted through the facility by the GSA Building Manager. The ACM survey included an inspection of the facility to determine the amount, condition, and general location of suspect ACM, and the collection of bulk samples for laboratory analysis. The bulk samples were analyzed by polarized light microscopy (PLM) by Davis Environmental Labs., located in Evanston, Illinois. CARNOW CONIBEAR inspectors reviewed existing documents, drawings, and historical reports, when available, and incorporated all data and assumptions into this report.
As part of the LBP survey, the CARNOW CONIBEAR field team collected paint chips representative of interior building substrates, including interior walls and ceilings. The LBP survey was limited to readily accessible surfaces of painted interior building components. The LBP survey activities included visual observations of interior painted surfaces and substrates of fixed building components and analysis of the painted surfaces.
The analysis of painted surfaces was conducted by STAT Analysis Corporation utilizing flame Atomic Absorption Spectroscopy (AAS). It should be noted that the LBP survey was not intended to be comprehensive in nature: rather an attempt to evaluate lead content within the predominant paint types within the building.
ACM and LBP Survey Summary Report Page 3 October 2007
2.0 BUILDING DESCRIPTION
The subject site’s address, 204 South Main Street, is within a business area of downtown South Bend, in St. Joseph County, Indiana. The subject site consists of a rectangular lot approximately 160 feet by 190 feet in size (approximately 0.69 acres), and is bounded by East Jefferson Boulevard to the north, West Main Street to the west, and alleyways to the east and south. The site contains the Robert A. Grant Federal Building and Courthouse, a three (3) floor federal court house and office building with one (1) basement floor with an interior parking lot, one (1) mezzanine, and a mechanical penthouse. The building was originally constructed in 1933, replacing building utilized by the post office and the Indiana Club. The building’s heating has been provided by natural gas-powered boilers and coal prior to that.
ACM and LBP Survey Summary Report Page 4 October 2007
3.0 ASBESTOS SURVEY PROTOCOL
3.1 Asbestos Survey
The ACM survey included an inspection of suspect friable and non-friable asbestos materials through-out the facility. Friable materials (such as thermal system pipe insulation (TSI)) are those which, when dry, can be crumbled, pulverized or reduced to powder by hand pressure, thereby releasing airborne fibers. Non-friable materials, such as floor tile, are those typically bound within a matrix, which do not readily release airborne fibers.
CARNOW CONIBEAR inspectors met with building representatives, reviewed drawings and historical data, and assigned Homogeneous Sampling Areas (HSA’s) based on the type of material, category, and appearance. The inventory of suspect materials identified during the walk-through includes a description of the material, location, condition, accessibility, and friability can be found in Table 1 - Asbestos Inventory and Analytical Summary.
Suspect ACM identified and sampled by CARNOW CONIBEAR as part of this survey included:
• Fittings Associated w/ Aircell Pipe Insulation
• 2’x4’ Smooth Ceiling Tiles
• 2’x4’ Ceiling Tiles w/ Holes
• Plaster
• Spray on Insulation
• Fiberglass Wall Paneling
• 2’x2’ Ceiling Tiles w/ Holes
• 2’x2’ Rough Ceiling Tiles
• White Sink Undercoating
Additional materials were identified during the survey; however these materials were not sampled and should be assumed to contain asbestos. The assumed materials were assessed as part of this survey and have been included in the report inventory.
Suspect ACM identified and assumed to contain asbestos included:
• Roof Material
• Elevator Outside Shell Materials
ACM and LBP Survey Summary Report Page 5 October 2007
The ACM survey only included identification of suspect ACM and did not include materials that are considered non-suspect in nature (e.g. fiberglass, concrete, wood, terrazzo, etc.) Per GSA, unique newly installed floor coverings were assumed NON-asbestos containing (see Table 1 for additional information).
CARNOW CONIBEAR inspectors walked through the building, inventoried suspect materials and quantities, took photographs, and wrote a narrative description of each suspect material. CARNOW CONIBEAR inspectors reviewed existing documents, drawings, and historical reports, when available, and incorporated as much data from the survey to create a building specific sampling plan. CARNOW CONIBEAR then collected the required number of samples and photographed each HSA. Photographs are located in Appendix C.
CARNOW CONIBEAR collected a total of thirty-six (36) bulk samples from various accessible materials during the survey. See Table 1 for a detailed description of the materials and analytical data. CARNOW CONIBEAR exercised care in selecting the locations from which the samples were collected. Each sample was immediately placed in a zip lock sample bag to reduce the possibility of fiber release and cross-contamination during sampling and shipment. Each collected sample was documented on a chain of custody sheet and relinquished to the asbestos laboratory by the inspector.
3.2 Asbestos Analysis
Bulk samples collected during the survey were submitted for analysis to Davis Environmental Labs, Inc. (DEL), of Evanston, Illinois. DEL is an American Industrial Hygiene Association (AIHA) accredited laboratory that successfully participates in the National Institute of Standards & Technology (NIST) National Voluntary Laboratory Accreditation Program (NVLAP) for asbestos bulk sample analysis.
CARNOW CONIBEAR collected a minimum of three bulk samples from each HSA.
Bulk samples were analyzed by polarized light microscopy (PLM) with dispersion staining and quantified in accordance with the Method for determination of Asbestos in Bulk Building Materials (USEPA Method 600/R-93/116).
3.3 Asbestos Survey Results
This section presents a summary of the analytical results of samples collected during the asbestos survey. Refer to Table 1 for further descriptions and additional information for the suspect materials identified during the survey. Facility maps which show the locations of materials can be found in Attachment A. The analytical laboratory report prepared by DEL for the analysis of bulk asbestos samples can be found in attachment B.
If a building material is determined to contain greater than or equal to 1% asbestos, it is considered to be ACM. If one sample in a HSA is determined to be positive for asbestos, the entire HSA is considered to be an ACM.
ACM and LBP Survey Summary Report Page 6 October 2007
Asbestos was identified in quantities greater than or equal to 1% in the following materials:
• Fittings Associated with Aircell Pipe Insulation
The following materials were not sampled at the time of the survey and are assumed to be
ACM:
• Roof Material
• Elevator Outside Shell Materials
The condition of the ACM observed at the time of the survey is listed in Table 1. Any materials encountered during the survey that could not be accessed or that would have required destructive sampling were not sampled. These materials include, but are not limited to roofing materials.
ACM and LBP Survey Summary Report Page 7 October 2007
4.0 LEAD-BASED PAINT SURVEY PROTOCOL
4.1 Lead Paint Survey
The lead based paint (LBP) survey included an inspection of the predominant types of paint within the building. Heather Eckard, an Illinois Department of Public Health licensed lead inspector/ risk assessor (IDPH license # L-10996), performed the inspection on August 21, 2007. During the survey of the building, CARNOW CONIBEAR collected two (2) samples for suspect LBP. (See Table 3 – Lead Paint Inventory Summary).
4.2 Lead Paint Analysis
The Environmental Protection Agency (EPA) defines LBP as any paint, varnish, shellac or other coating that contains lead in concentrations that are equal to or in excess of one milligram per square centimeter (1.0 mg/cm2), 0.5% by weight or 5,000 parts per million (ppm). The Occupational Safety and Health Administration (OSHA) recognizes LBP as paint that contains any detectable amount of lead. Under OSHA, paints containing lead in concentrations less than the trigger level are subject to regulation under OSHA Lead in Construction; Interim Final Rule (29 CFR 1926.62).
Although the use of lead paint was banned in 1978 by the Consumer Product Safety Commission (CPSC), consumer paints still contain up to 0.06% lead by weight or 600 ppm. Lead based paints are still commonly used in many applications.
4.3 Lead Paint Survey Results
Based upon results of the lead-based paint testing, LBP was identified on the following:
• Brown on Exterior Wood Window Sill
• Beige on Plaster Wall
See Table 3 – Lead Paint Inventory and Analytical Summary, for LBP descriptions, sample identification numbers and locations, and paint conditions. The analytical laboratory report for the analysis of paint chips can be found in Attachment B.
ACM and LBP Survey Summary Report Page 8 October 2007
5.0 CONCLUSIONS AND RECOMENDATIONS
CARNOW CONIBEAR recommends the following:
• Prior to Prospectus Design and & Construction work, additional building investigations should be conducted in order to ascertain quantities and to verify that conditions have not changed since the most recent inspection.
• GSA should notify employees, tenants, contractors, and vendors working in the building of the presence, quantity, and location of identified or assumed ACM.
• All friable ACM, damaged non-friable ACM, and all non-friable ACM which may become friable during renovation or demolition, should be removed from the affected areas of the building prior to these activities.
• Areas of the building not inspected during this investigation (inaccessible areas, pipe chases, etc.) should be inspected and sampled for asbestos prior to any renovation, demolition, or disturbance of potential ACM.
• The owner should develop and/or maintain an Operations and Maintenance (O&M) Plan for ACM remaining in the facility.
The EPA’s NESHAP (40 CFR Part 61) requires building owners to inspect of ACM in areas of a building where renovation or demolition will take place. Prior to renovation or demolition of a building, all regulated friable ACM must be removed from the affected area. In addition, non-friable materials, which are in a damaged condition or are likely to become friable during the process of renovation or demolition also, require removal. Non-friable materials, which are in good condition at the time of inspection and most likely will not become friable during demolition may under certain circumstances, remain in place prior to demolition.
Under current federal regulations, lead-based paint that is intact does not need to be removed prior to demolition, however, the contractor performing the demolition is required to comply with the OSHA Lead in Construction Standard (29 CFR 1926.62).
Demolition or salvage of structures where lead or materials containing lead are present is on section of OSHA Regulation (1926.62 (a)(1)). OSHA requires employers to conduct personal air monitoring during construction work where painted surfaces that contain detectable amounts of lead are impacted. OSHA defines construction work as work for the purposes of construction, alteration and/or repair (including repainting and decorating). The purpose of the exposure monitoring is to ensure that employees are not exposed to lead at concentrations that exceed the permissible exposure level (PEL) of fifty micrograms of lead per cubic meter of air (50 mg/m3) or the action level (AL) of thirty micrograms of lead per cubic meter of air (30 mg/m3) over an 8-hour period. Should the exposure exceed the AL or PEL over an 8-hour time period, the employer will be required to provide the employee with some or all of the following: appropriate respiratory protection, personal protective clothing, change areas, hand washing facilities, biological monitoring (blood sampling and analysis), and the proper training.
ACM and LBP Survey Summary Report Page 9 October 2007
6.0 STUDY LIMITATIONS
This report and all field data, notes, and laboratory test data were gathered and/or prepared by CARNOW CONIBEAR in accordance with the agreed-upon scope of work and generally accepted engineering and scientific practices in effect at the time of CARNOW CONIBEAR’s investigation of the building.
The statements, conclusions, and opinions contained in this report are only intended to give approximations of the environmental conditions of the site limited to the particular environmental issues actually targeted by CARNOW CONIBEAR’s investigation as agreed upon by the GSA and CARNOW CONIBEAR. This survey was conducted to fulfill the requirements of the Program Development Study (PDS) for the Prospectus Report and is not recommended to be used a guide to facilitate renovation, demolition, or removal of ACM or LBP. CARNOW CONIBEAR inspection team did not pull up all carpet or check above every ceiling tile throughout the building. The inspection team did not conduct any destructive sampling, nor sample materials that appeared to have historical value. CARNOW CONIBEAR’s inspection team assumed that certain portions of tenant build-out spaces were uniform with the remainder of the space in many areas.
There were many areas not made accessible to CARNOW CONIBEAR inspectors due to security issues or access limitations.
This report and supporting field data, notes, and laboratory test data, where applicable, where prepared or collected by CARNOW CONIBEAR for its client, to be utilized by GSA in the Program Development Study (PDS) for the Prospectus Report. CARNOW CONIBEAR’s client may release the information to third parties, who may use and rely upon the information at their discretion. However, any use or reliance upon the information by a party other than specifically named above shall be solely at the risk of such third party and without legal recourse against CARNOW CONIBEAR, or their respective employees, officers or directors, regardless of whether the action in which recovery of damage is sought based upon contract, tort (including the sole, concurrent, or other negligence and strict liability of CARNOW CONIBEAR), statute, or otherwise.
This information shall not be used or replied upon by a party that does not agree to be bound the above statement.
ACM and LBP Survey Summary Report Page 10 October 2007
7.0 SIGNATURE AND QUALITY CONTROL PAGE
BY:
DATE: October 2007
Lindsey Felker Report Author
TITLE: Industrial Hygiene Technician
QUALITY CONTROL REVIEW BY:
BY: DATE: October 2007 Heather Eckard
TITLE: Licensed Asbestos Building Inspector (IDPH #:100-10397)
Licensed Lead Inspector/ Risk Assessor (IDPH #: L-10996)
TABLE 1 – ASBESTOS INVENTORY AND ANALYTICAL
SUMMARY
Inspector:
Heather Eckard (IDPH #100-10397)
Building:
Robert A Grant Federal Building and U.S. Courthouse 204 South Main Street South Bend, Indiana
Survey Date: August 21, 2007
HSA ID Material Type Material Description Sample # Sample Location Condition Friability Accessibility Assessment Category Quantity Asbestos % & Type Notes
HSA-1-1 Basement Storage 5-10% Chrysotile HSA-1-2 Basement Storage 5-10% Chrysotile HSA-1-3 Basement Storage 5-10% Chrysotile HSA-2-1 Basement Storage 1-5% Chrysotile HSA-2-2 Basement Storage 1-5% Chrysotile HSA-2-3 Basement Storage 1-5% Chrysotile HSA-3-1 Stockpile ND HSA-3-2 Stockpile ND HSA-3-3 Stockpile ND HSA-4-1 Stockpile ND HSA-4-2 Stockpile ND HSA-4-3 Stockpile ND HSA-8-1 SW Stairway ND HSA-8-2 SW Stairway ND HSA-8-3 SW Stairway ND
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
HSA-13-1 Parking Garage ND HSA-13-2 Parking Garage ND HSA-13-3 Parking Garage ND
NS NS NS
NS NS NS
NS NS NS
HSA-15-1 Penthouse ND HSA-15-2 Penthouse ND HSA-15-3 Penthouse ND HSA-16-1 Storage ND HSA-16-2 Storage ND HSA-16-3 Storage ND HSA-17-1 Storage ND HSA-17-2 Storage ND HSA-17-3 Storage ND
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
HSA-22-1 Mezzanine Level Break Room ND HSA-22-2 Mezzanine Level Break Room ND HSA-22-3 Mezzanine Level Break Room ND
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
HSA-25-1 Basement 1-5% Chrysotile HSA-25-2 Basement 1-5% Chrysotile HSA-25-3 Basement 1-5% Chrysotile
ACMFriable 2 X 3,000 lfHSA - 25 TSI Paperwrap Pipe Insulation 1
Assume Non-ACM per GSA
HSA - 24 MISC 12" x 12" Grey Mix Floor Tile Mastic 1 Non-Friable 1 X NQ Assume Non-ACM per GSA
Non-Friable 3 X NQHSA - 23 MISC 12" x 12" Grey Mix Floor Tile 1
Assume Non-ACM per GSA
HSA - 22 MISC White Sink Undercoating 1 Non-Friable 3 X NQ Non-ACM
Non-Friable 1 X NQHSA - 21 MISC 12" x 12" Light Blue Floor Tile Mastic 1
Assume Non-ACM per GSA
HSA - 20 MISC 12" x 12" Light Blue Floor Tile 1 Non-Friable 3 X NQ Assume Non-ACM per GSA
Non-Friable 1 X NQHSA - 19 MISC 12" x 12" Light Yellow Floor Tile Mastic 1
3 X NQ Assume Non-ACM per GSAMISC 12" x 12" Light Yellow Floor Tile 1 Non-Friable
Non-ACM
HSA - 17 MISC 2' x 2' Rough Ceiling Tile 1 Friable 2 X NQ Non-ACM
NQ Non-ACM
HSA - 16 MISC 2' x 2' with Holes Ceiling Tile 1 Friable 2 X NQ
1 Non-Friable 3 X
20 sf Assume ACMNon-Friable 3
3 X NQ
Friable 3 X NQ
Table 1: Asbestos Inventory and Analytical Summary
HSA - 11 MISC 12" x 12" Tan Mix Floor Tile 1 Assume Non-ACM per GSANon-Friable
Non-ACM Non-Friable 3
HSA - 13 SURF Spray-on Fireproofing
HSA - 14 MISC Vibration Damper
HSA - 15 MISC
HSA - 18
Fiberglass Wall Paneling
1 Non-ACM
Non-Friable 1 X NQ Assume Non-ACM per GSA
1 X
HSA - 12 MISC 12" x 12" Tan Mix Floor Tile Mastic 1
X NQHSA - 8 SURF Plaster 1
Non-ACM
HSA - 4 MISC 2' x 4' with Holes Ceiling Tile 1 Friable 2 X NQ Non-ACM
Friable 2 X NQHSA - 3 MISC 2' x 4' Smooth Ceiling Tile 1
ACM
HSA - 2 TSI Fittings Associated w/ Aircell Pipe Insulation 1 Friable 2 X 100 lf ACM
Friable 2 X 7,000 lfHSA - 1 TSI Aircell Pipe Insulation 1
Building:
Robert A Grant Federal Building and U.S. Courthouse 204 South Main Street South Bend, Indiana
Survey Date: August 21, 2007
HSA ID Material Type Material Description Sample # Sample Location Condition Friability Accessibility Assessment Category Quantity Asbestos % & Type Notes
Table 1: Asbestos Inventory and Analytical Summary
HSA-26-1 Basement 1-5% Chrysotile HSA-26-2 Basement 1-5% Chrysotile HSA-26-3 Basement 1-5% Chrysotile
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS- No Sample Material Type: Condition: Accessibility: Assessment Category:
ND- Non-Detect TSI - Thermal System Insulation 1 - No Damage 1 - Low 1 - Damaged or significantly damaged TSI.
NA-Not Analyzed SM - Surfacing Material 2 - Slightly Damaged 2 - Medium 2 - Damaged friable surfacing ACM.
NQ- Not Quantified MISC - Miscellaneous Material 3 - Damaged 3- High 3 - Significantly damaged friable surfacing ACM.
lf-Linear Foot 4 - Significant Damage 4 - Damaged or significantly damaged friable miscellaneous ACM.
sf-Square Foot 5 - ACBM with potential for significant damage
6 - ACBM with potential for damage.
7 - Any remaining friable ACBM or friable suspected ACBM
Assume ACM
MISC Elevator Outer Shell Material 1 Non-Friable 1 X NQ Assume ACM
Non-Friable 1 X 30,000 sfHSA - 27 MISC Roofing Material 1
HSA - 26 TSI Fittings Associated w/ Paperwrap Pipe Insulation 1 Friable 2 X 30 lf ACM
HSA - 28
TABLE 2 – ASBESTOS CONTAINING MATERIALS
Inspectors:
Building:
Robert A. Grant Federal Building and U.S. Courthouse 204 South Main Street South Bend, Indiana
Survey Date: August 21, 2007
HSA ID Material Type Material Description Sample # Sample Location Condition Friability Accessibility Assessment Category Quantity Asbestos % & Type Notes
HSA-1-1 Basement Storage 5-10% Chrysotile HSA-1-2 Basement Storage 5-10% Chrysotile HSA-1-3 Basement Storage 5-10% Chrysotile HSA-2-1 Basement Storage 1-5% Chrysotile HSA-2-2 Basement Storage 1-5% Chrysotile HSA-2-3 Basement Storage 1-5% Chrysotile
NS NS NS
NS NS NS
NS NS NS
HSA-25-1 Basement 1-5% Chrysotile HSA-25-2 Basement 1-5% Chrysotile HSA-25-3 Basement 1-5% Chrysotile HSA-26-1 Basement 1-5% Chrysotile HSA-26-2 Basement 1-5% Chrysotile HSA-26-3 Basement 1-5% Chrysotile
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
NS NS NS
Key:
NS- No Sample Material Type: Condition: Accessibility: Assessment Category:
ND- Non-Detect TSI - Thermal System Insulation 1 - No Damage 1 - Low 1 - Damaged or significantly damaged TSI.
NA-Not Analyzed SM - Surfacing Material 2 - Slightly Damaged 2 - Medium 2 - Damaged friable surfacing ACM.
NQ- Not Quantified MISC - Miscellaneous Material 3 - Damaged 3- High 3 - Significantly damaged friable surfacing ACM.
lf-Linear Foot 4 - Significant Damage 4 - Damaged or significantly damaged friable miscellaneous ACM.
sf-Square Foot 5 - ACBM with potential for significant damage
6 - ACBM with potential for damage.
7 - Any remaining friable ACBM or friable suspected ACBM
Non-Friable 1 XHSA - 28 MISC Elevator Outer Shell Material 1 900 sf Assume ACM
30 ACM
Assume ACM30,000 sfHSA - 27 MISC Roofing Material 1
X
HSA - 25
Non-Friable 1 X
HSA - 26 TSI Fittings Associated w/ Paperwrap Pipe Insulation 1
TSI Paperwrap Pipe Insulation 1
Assume ACMX 20 sf
X 3,000 ACM
Non-Friable 3
Friable 2
Friable 2
HSA - 14 MISC Vibration Damper 1
ACM
Table 2: Asbestos Containing Materials
Friable 2 X 7,000HSA - 1 TSI Aircell Pipe Insulation 1
HSA - 2 TSI Fittings Associated w/ Aircell Pipe Insulation 1 ACMFriable 2 X 100 lf
TABLE 3 – LEAD PAINT INVENTORY SUMMMARY
Heather Eckard (L-10996)
Building:
Robert A. Grant Federal Building and U.S. Courthouse 204 South Main Street
South Bend, Indiana 46601
Survey Date: September 20, 2007
Sample ID # Sample Location Component Substrate Color Result
LBP-01 Exterior (Roof) Window Sill Wood Brown 230,000 mg/Kg
LBP-02 1st Floor Wall Plaster Beige 160,000 mg/Kg
Table 3: Lead Paint Inventory Summary
ATTACHMENTS
ATTACHMENT A – FACILITY MAPS: LOCATIONS OF ACM
ATTACHMENT B – ASBESTOS AND LEAD LABORATORY
ANALYTICAL REPORTS
ATTACHMENT C – PHOTOGRAPHS
ATTACHMENT D – FIELD NOTES
ATTACHMENT E – COST ESTIMATE
Building:
Robert A. Grant Federal Building and U.S. Courthouse
204 South Main Street South Bend, Indiana
ASBESTOS COST ESTIMATE
Survey Date: August 21, 2007
Material Descripton Quantity Unit Unit Price Line Total Asbestos Pipe Insulation 10,000 lf $25.00 $250,000.00 Asbestos Pipe Fittings 130 each $25.00 $3,250.00 Elevator Shell Material 900 sf $25.00 $22,500.00 Vibration Damper 3 sf $500.00 $1,500.00 Roof Materials 30,000 sf $2.75 $82,500.00
ESTIMATED ABATEMENT COSTS: $359,750.00
Other Costs: Fee
Asbestos Project Design and Bid Award Services
Abatement Monitoring and Air Testing
Approximately 10% of Project Award for Abatement
$480.00/day and $15.00 per sample
*Unit Price for each material includes labor costs (containment construction, abatement, cleanup), materials, equipment, suplies, disposal, and insurance
** Roofing materials unit price assumes roof is "built-up" (multiple layers).
| Drawings.pdf |
| SouthBend-BASEMENT ALL ACM (1).pdf |
| SouthBend-BASEMENT HSA 1 (ACM) (1).pdf |
| SouthBend-BASEMENT HSA 2 (ACM) (1).pdf |
| SouthBend-BASEMENT HSA 3 (NON-ACM) (1).pdf |
| SouthBend-BASEMENT HSA 4 (NON-ACM) (1).pdf |
| SouthBend-BASEMENT HSA 8 (NON-ACM) (1).pdf |
| SouthBend-BASEMENT HSA 11 (NON-ACM PER GSA) (1).pdf |
| SouthBend-BASEMENT HSA 12 (NON-ACM PER GSA) (1).pdf |
| SouthBend-BASEMENT HSA 13 (NON-ACM) (1).pdf |
| SouthBend-BASEMENT HSA 14 (ASSUMED ACM) (1).pdf |
| SouthBend-BASEMENT HSA 16 (NON-ACM) (1).pdf |
| SouthBend-BASEMENT HSA 17 (NON-ACM) (1).pdf |
| SouthBend-BASEMENT HSA 25 (ACM) (1).pdf |
| SouthBend-BASEMENT HSA 26 (ACM) (1).pdf |
| SouthBend-FIRST ALL ACM (1).pdf |
| SouthBend-FIRST HSA 4 (NON-ACM) (1).pdf |
| SouthBend-FIRST HSA 8 (NON-ACM) (1).pdf |
| SouthBend-FIRST HSA 11 (NON-ACM PER GSA) (1).pdf |
| SouthBend-FIRST HSA 12 (NON-ACM PER GSA) (1).pdf |
| SouthBend-FIRST HSA 14 (ASSUMED ACM) (1).pdf |
| SouthBend-FIRST HSA 17 (NON-ACM) (1).pdf |
| SouthBend-FIRST HSA 18 (NON-ACM PER GSA) (1).pdf |
| SouthBend-FIRST HSA 19 (NON-ACM PER GSA) (1).pdf |
| SouthBend-FIRST HSA 23 (NON-ACM PER GSA) (1).pdf |
| SouthBend-FIRST HSA 24 (NON-ACM PER GSA) (1).pdf |
| SouthBend-FIRST HSA 25 (ACM) (1).pdf |
| SouthBend-FIRST HSA 26 (ACM) (1).pdf |
| SouthBend-FIRST HSA 28 (ASSUMED ACM) (1).pdf |
| SouthBend-MEZZANINE ALL ACM (1).pdf |
| SouthBend-MEZZANINE HSA 4 (NON-ACM) (1).pdf |
| SouthBend-MEZZANINE HSA 8 (NON-ACM) (1).pdf |
| SouthBend-MEZZANINE HSA 20 (NON-ACM PER GSA) (1).pdf |
| SouthBend-MEZZANINE HSA 21 (NON-ACM PER GSA) (1).pdf |
| SouthBend-MEZZANINE HSA 22 (NON-ACM) (1).pdf |
| SouthBend-SECOND ALL ACM (1).pdf |
| SouthBend-SECOND HSA 4 (NON-ACM) (1).pdf |
| SouthBend-SECOND HSA 8 (NON-ACM) (1).pdf |
| SouthBend-SECOND HSA 13 (NON-ACM) (1).pdf |
| SouthBend-SECOND HSA 14 (ASSUMED ACM) (1).pdf |
| SouthBend-SECOND HSA 16 (NON-ACM) (1).pdf |
| SouthBend-SECOND HSA 17 (NON-ACM) (1).pdf |
| SouthBend-THIRD ALL ACM (1).pdf |
| SouthBend-THIRD HSA 4 (NON-ACM) (1).pdf |
| SouthBend-THIRD HSA 8 (NON-ACM) (1).pdf |
| SouthBend-THIRD HSA 14 (ASSUMED ACM) (1).pdf |
| SouthBend-THIRD HSA 16 (NON-ACM) (1).pdf |
| SouthBend-THIRD HSA 17 (NON-ACM) (1).pdf |
| SouthBend-PENTHOUSE ALL ACM (1).pdf |
| SouthBend-PENTHOUSE HSA 15 (NON-ACM) (1).pdf |
| SouthBend-PENTHOUSE HSA 27 (ASSUMED ACM) (1).pdf |
| Photographic Log.pdf |
| Photographic Log 1 (1).pdf |
| Photographic Log 2 (1).pdf |
| Photographic Log 3 (1).pdf |
| Photographic Log 4 (1).pdf |
| Photographic Log 5 (1).pdf |
| Photographic Log 6 (1).pdf |
| Photographic Log 7 (1).pdf |
| Photographic Log 8 (1).pdf |
File details come from the government source that posted it. Updated .