GOB_Drawings_Attachment_1_compressed.pdf
PDF 3 MB Posted
- Attached to
- EXT REC | CON26-0011 Geneva Office Ext - MLBE
- Solicitation number
- SFGOV-0000011112
- Issued by
- San Francisco County, San Francisco City, California
About this file
This document set comprises architectural drawings and project specifications for the City and County of San Francisco's exterior improvements project at the Geneva Office Building, located at 2301 San Jose Avenue, San Francisco, California. The project scope encompasses four primary work categories: brick cleaning and repair on the San Jose and Geneva Avenue facades, including removal of graffiti, improper paint coatings, and biological growth with selective replacement and repointing of masonry; installation of new gutters and downspouts around the entire building perimeter; in-kind repair of four bay windows along the San Jose Avenue facade and a wood turret on the Geneva Avenue facade; and replacement of entry door protection systems and vents on plywood panels along the San Jose Avenue facade. A non-mandatory pre-bid meeting is scheduled for Wednesday, October 1, 2025, at 2:00 pm at the Power House adjacent to the Office Building. All project-related questions must be submitted by Wednesday, October 8, 2025, at 5:00 pm to sanjana.appachu@sfgov.org with a copy to bridget.webster@sfgov.org. Sealed bids are due by Wednesday, October 15, 2025, at 2:30 pm via email to bridget.webster@sfgov.org. The overall contract period extends through January 1, 2027, with an Addendum #1 posted on October 9, 2025, that does not modify the bid due date.
This solicitation requires a California Class B contractor license and carries a cost estimate of $153,000 for the complete scope of exterior improvements. The project is designated as a Minority/Local Business Enterprise (MLBE) set-aside, restricting qualified bidding to certified minority and local business enterprises as defined by San Francisco procurement policies. Prospective bidders must demonstrate compliance with all licensing requirements and provide evidence of MLBE certification status to be considered for award. The project is managed by the San Francisco Recreation and Parks Department's Capital and Planning Division.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Original Sheet Size: 36" x 24"
Sheet No.
Drawing Title
Project No.
DAC
Proj. Mgr.
Project
Scale:
Drawn
COVER SHEET
G 0.0
RP10042254
Checked by
49 Van Ness Ave., Suite 1200, San Francisco, CA 94102
NO SCALE
GENEVA OFFICE BUILDING
EXTERIOR IMPROVEMENTS PROJECT
2301 San Jose Avenue, San Francisco, CA 94112
LOCATION MAP
SCOPE OF WORK
I. Brick
• Cleaning brick on the San Jose and Geneva Ave facades
• Removal of gra�ti, improper paint coatings and biological growth from existing brick
• Selective replacement/patching of existing brick and pointing/repointing of masonry
II. Gutters and Downspouts
• Installation of new gutters and downspouts around the entire building to match existing
III. Wood
• In kind repair of four bay windows along San Jose Ave façade, and wood turret on Geneva
Ave façade
IV. Windows and Doors
• Northernmost entry doors on west elevation (San Jose Ave) to be protected with a plywood system similar to the one at the southernmost entrance located between the bay windows
• Replacement of vents on plywood panels along San Jose Ave facade
SHEET INDEX
G 0.0 COVER SHEET
A1 SITE PLAN
A1.1 ENLARGED SITE PLAN
A2 SCOPE OF WORK
A2.1 FIRST FLOOR PLAN
A3 EAST AND WEST ELEVATIONS
A4 NORTH AND SOUTH ELEVATIONS
CAPITAL AND PLANNING DIVISION
100% SUBMITTAL
No. Date Revisions
DATE
Project Location 2301 San Jose Avenue, San Francisco, CA 94112
GENEVA OFFICE BUILDING EXTERIOR IMPROVEMENTS
A RECREATION AND PARKS DEPARTMENT PROJECT
PROJECT I.D. NO. RP10042254
Drawing Title
Project No.
DAC
Proj. Mgr.
Project
Scale:
Drawn
DAC CHECK LIST
G 1.0
RP10042254
Checked by
49 Van Ness Ave., Suite 1200, San Francisco, CA 94102
NO SCALE
GENEVA OFFICE BUILDING
EXTERIOR IMPROVEMENTS PROJECT
2301 San Jose Avenue, San Francisco, CA 94112
CAPITAL AND PLANNING DIVISION
100% SUBMITTAL
No. Date Revisions
DATE
Drawing Title
Project No.
DAC
Proj. Mgr.
Project
Scale:
Drawn
DAC PROJECT REVIEW
G 1.1
RP10042254
Checked by
49 Van Ness Ave., Suite 1200, San Francisco, CA 94102
NO SCALE
GENEVA OFFICE BUILDING
EXTERIOR IMPROVEMENTS PROJECT
2301 San Jose Avenue, San Francisco, CA 94112
CAPITAL AND PLANNING DIVISION
100% SUBMITTAL
No. Date Revisions
DATE
GENEVA OFFICE BUILDING
ARCHITECTURAL STABILIZATION
SITE PLAN
A1
A4
SITE PLAN
Limits of Project Site
SCALE 1/32"=1'-0"
ENLARGED SITE PLAN
A1.1
A4
ENLARGED SITE PLAN
10 - THE MUNI STREET CAR YARD EAST OF
THE OFFICE BUILDING,
VIEW FROM THE NORTH
11 - THE NORTHEAST CORNER OF THE
OFFICE BUILDING
1 - THE NORTHWEST CORNER OF THE
OFFICE BUILDING
2 - THE NORTH ELEVATION AND TOWER
OF THE OFFICE BUILDING
3 - SITE ADJACENT TO THE WEST
ELEVATION OF THE OFFICE BUILDING
4 - THE WEST ELEVATION OF THE POWERHOUSE 5 - POWERHOUSE ADJACENT TO OFFICE BUILDING 6 - SITE ADJACENT TO THE WEST OF THE
POWERHOUSE
SCALE
1/16"=1'-0"
SCOPE OF WORK
A2
A4
A
DC C
B
C C C
A
E
Brick cleaning, removal of gra�ti, improper paint coatings and biological growth on existing brick on west and north facades
B Installation of new gutters and downspouts around entire building
C In kind repair/replacement of four bay windows and wood turret
D Entry door to be protected with a plywood system similar to the one at the southernmost entrance located between the Bay windows
E Replacement of vents on window plywood panels on west facadeNorthernmost entry door Weathering of brick and rusted downspout Deteriorated bay window
West elevation
Missing vents in window plywood
FIRST FLOOR PLAN
A2.1
A4
FIRST FLOOR PLAN
SCALE 1/8"=1'-0"
CCCCC D
Installation of new gutters and downspouts around entire building
In kind repair/replacement of four bay windows and wood turret
Entry door to be protected with a plywood system similar to the one at the southernmost entrance located between the Bay windows
Replacement of vents on window plywood panels on west facade
A
B
C
D
E
Brick cleaning, removal of gra�ti, improper paint coatings and biological growth on existing brick on west and north facades
46'
EAST ELEVATION
SCALE 1/8"=1'-0"
WEST ELEVATION
28'-2"
SCALE 1/8"=1'-0"
GENEVA OFFICE BUILDING
ARCHITECTURAL STABILIZATION
EAST & WEST ELEVATIONS
A3
(N) GALVANIZED STEEL, PAINTED DOWNSPOUTS INTO
(E) DRAIN BOOTS. VERIFY BOOT LOCATIONS
(N) GALVANIZED STEEL, PAINTED DOWNSPOUTS INTO
(E) DRAIN BOOTS. VERIFY BOOT LOCATIONS
NOTE: NUMBERS INDICATE WINDOW PROTECTION TYPE - SEE SHEET A4
LETTERS A,B,C & D INDICATE SCOPE OF WORK FOR RESPECTIVE AREAS - SEE SHEET A2
A4
C D C C
B BB B
B
NORTH & SOUTH ELEVATIONS
A4
A4
NORTH ELEVATION
SCALE 1/8"=1'-0"
SOUTH ELEVATION
TYPICAL WINDOW PROTECTION PANELS
SCALE 1/8"=1'-0"
SCALE 1/2"=1'-0"
| GOB_Drawings_Attachment 1.pdf |
| Cover Sheet_Geneva Office Building Exterior Improvements.pdf |
| DAC Checklist.pdf |
| DAC Project Review.pdf |
| GOB_Drawings_Attachment 1 |
| GOB_Drawings.pdf |
| A1.pdf |
| A1.1.pdf |
| A2.pdf |
| A2.1.pdf |
| A3.pdf |
| A4.pdf |
File details come from the government source that posted it. Updated .