FP2.08_ LEVEL 8 -FIRE PROTECTION PLAN Rev.6 markup.pdf

PDF 2 MB Posted

Attached to
Fire suppression system Preventative Maintenance TRD03 RFQ
Solicitation number
BD-27-1053-1053C-CSR-132423
Issued by
Hampden County, Massachusetts

About this file

This is a Fire Protection Plan drawing for the Soldiers' Home in Holyoke, a Massachusetts state agency long-term care facility. The document is a revised architectural plan (Revision 6) detailing the fire suppression system layout for Level 8 of the 234-bed facility located at 110 Cherry Street in Holyoke, Massachusetts. The plan illustrates the placement and coordination of sprinkler piping, control valves, fire department connections, and related fire protection components throughout resident bedrooms, bathrooms, dining areas, activity rooms, mechanical spaces, and support areas on the eighth floor. The drawing includes specifications for 6-inch fire sprinkler piping with up and down risers, 3-inch sectional drains, 4-inch pressure relief valves, 4-inch flow control valves for two separate zones, 2.5-inch fire department connections, and 2-inch supervised valves and sprinkler caps for future use. The plan was originally issued on January 10, 2023, and has undergone five bulletins with revisions as recently as May 16, 2025, indicating ongoing design refinement and coordination with related building systems including ceiling plans and floor layouts.

The Fire Protection Plan demonstrates compliance with NFPA 25, NFPA 101, and Massachusetts Comprehensive Fire Safety Code (527 CMR) standards, with design coordination managed by Payette Associates Inc. of Boston and BR+A Consulting Engineers. The document serves as the technical foundation for the preventative maintenance and inspection agreement referenced in the related request for quotes, which requires annual testing, inspection, and maintenance services performed by qualified contractors under prevailing wage rates established by the Massachusetts Department of Labor Standards. All work must comply with regulatory oversight from the Department of Public Health, Centers for Medicare & Medicaid Services, and the Department of Veterans Affairs, with advance notification and coordination required with facility administrators to minimize disruption to residents.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

BW

DW

EW

FW

GW

HW

JW

KW

LW

BE

CE

DE

EE

FE

GE

HE

JE

CS

DS

ES

FS

GS

HS

JS

PC

LS

3E

2W

3N

4N

4E

1W

3W

2N

2E

1E

4W

1N

AW

AS

2W.2

AE

NW

MS

KE

BS

5N

4N.1

6"FSP UP&DN

3"SD UP&DN

4"PRV

4"FCVA - ZONE 1

2-1/2"FDV

6"FSP UP

3"SD UP

6"NRS GATE VALVE.

6"FSP UP TO ROOF HYDRANT.

6"FSP DN&RISE

3"SD DN&RISE

4"PRV

4"FCVA - ZONE 2

2-1/2"FDV

4" S

PR

-2

SEE FP 3.01 FOR ENLARGED PLAN

PROVIDE SPRINKLERS AND PIPING

THROUGHOUT ALL AREAS AS REQUIRED.

COORDINATE WITH FLOOR PLAN

AND CEILING PLAN.

6" F

SP

6" F

SP

14 6"FSP DN&RISE

3"SD DN&RISE

2-1/2"FDV

W852

RESIDENT

BEDROOM

E820A

TLT/SH

W819

DINING

ROOM

E823

RESIDENT

BEDROOM

E822

RESIDENT

BEDROOM

E821

RESIDENT

BEDROOM

E820

RESIDENT

BEDROOM

E821A

TLT/SH

E822A

TLT/SH

E823A

TLT/SH

E831

RESIDENT

BEDROOM

E830

RESIDENT

BEDROOM

E829

RESIDENT

BEDROOM

E828

RESIDENT

BEDROOM

E827

RESIDENT

BEDROOM

E826

RESIDENT

BEDROOM

E825

RESIDENT

BEDROOM

E829A

TLT/SH

E828A

TLT/SH

E825A

TLT/SH

N813

WHEELCHAIR

STORAGE

E813A

STORAGE

N811

FAMILY

LAUNDRY

W8V2

ELECTRICAL

W8V1

EMERG.

ELEC.

W814

STAFF

LOUNGE

W808

STAFF TLT

W809

STAFF TLT

W806

LINEN

STORAGE W807

TOILET

W813A

LOCKERS

W810

VEST.

W813

PASSAGE

E801A

NURSE

STATION

W804

SOILED

UTILITY

W801A

NURSE

STATION

W802

MEDS

ROOM

W805

EQUIP

STORAGE

E803

CLEAN

UTILITY

E802

MEDS

ROOM

E808

TOILET

E806

LINEN

STORAGE

E804

SOILED

UTILITY

E805

STORAGE

E818

JANITOR'S

CLOSET

E817

VRF

W816

FOOD/WARMING

PREP

W817

VRF

N816

EDUCATION

N815

WORKROOM

E811

ACTIVITY

ROOM

W819A

QUIET

DINING

E813

QUIET

LIVING

ROOM

E812

LIVING

ROOM

W849

DEN/LIBRARY

E824

DEN/LIBRARY

W840

RESIDENT

BEDROOM

W841

RESIDENT

BEDROOM

W842

RESIDENT

BEDROOM

W843

RESIDENT

BEDROOM

W844

RESIDENT

BEDROOM

W845

RESIDENT

BEDROOM

W846

RESIDENT

BEDROOM

W847

RESIDENT

BEDROOM

W848

RESIDENT

BEDROOM

W850

RESIDENT

BEDROOM

W851

RESIDENT

BEDROOM

W812

ELEVATOR

LOBBY

W818

JANITOR'S

CLOSET E810

VEST.

E800

VEST.

E801

CORRIDOR

W801

CORRIDOR

W840A

TLT/SH

W841A

TLT/SH

W842A

TLT/SH

W843A

TLT/SH

W844A

TLT/SH

W845A

TLT/SH

W846A

TLT/SH

W847A

TLT/SH

W848A

TLT/SH

W850A

TLT/SH

W851A

TLT/SH

W852A

TLT/SH

PASSENGER

ELEVATOR

SERVICE

ELEVATOR

W1

STAIR

E1

STAIR

E824A

STORAGE

ME3

SHAFT

MW1

SHAFT

MW2

SHAFT

ME2

SHAFT

W815

KITCHENETTE

PASSENGER

ELEVATOR

PASSENGER

ELEVATOR

N1

STAIR

W849A

STORAGE

N818

LACTATION

N805

MECHANICAL

W811

CIRCULATION

E807

BATHING

ROOM

N8D1

TEL/DATA

N814

MUSIC

ROOM

E809

TOILET

E814

TOILET

W810A

SERVICE

ELEVATOR

LOBBY

W800

VEST.

2"SPR CAPPED FOR FUTURE USE

2"SUPERVISED VALVE

2"SPR TO INTENDED TO PROVIDE

PROTECTION TO TOP OF

ELEVATOR SHAFTS BY OTHERS

SPRINKLERS IN SHAFT SHALL

REQUIRE CODE VARIANCE

AQUIRED BY OTHERS

N1

W1

E1

W2

N2

E2

S1

0'

Project Name:

DCAMM Project Number:

Project Location

Project Architect

Site Number:

CAMIS Number:

Building Number:

Secretariat:

F ile

P a th

Original Issue Date

Revisions

Drawing Title:

Drawing Number:

Project Consultant

HLY2102

Payette Associates Inc.

290 Congress Street, Fifth Floor Boston, MA 02210-1005 Tel: 617-895-1000 www.payette.com

Project Number:

40158.00

10' 20' 40'

HLY 00

N/A

256 HLY 0010

E.O.H.H.S

BR+A CONSULTING ENGINEERS

10 Guest Street, 4th Floor

Boston, MA 02135

617.254.0016 brplusa.com

B

IM

/H o ly o k e S o ld ie rs

H o m e /3

H

S H

C

S B

R

A P

F P

O

R .r v t

LEVEL 8 - FIRE

PROTECTION PLAN

FP2.08

01/10/2023

SOLDIERS' HOME

IN HOLYOKE

LONG-TERM

CARE PACKAGE

110 Cherry Street Holyoke, MA 01040

1/16" = 1'-0"

LEVEL 8 - OVERALL FIRE PROTECTION PLAN

1/16" = 1'-0" LEVEL 8 - Working RCP for PFP

No. Description Date

1 BULLETIN # 28R1 03/08/2024

2 BULLETIN # 39 04/19/2024

3 BULLETIN #91 01/31/2025

4 BULLETIN #118 05/16/2025

5 BULLETIN #172R1 03/13/2026

https://app.procore.com/1526478/project/drawing_areas/1845139/drawing_log/329743308

File details come from the government source that posted it. Updated .