Florida_Trench_Safety_Form.pdf
PDF 96 KB Posted
- Attached to
- STAR Center Chiller 2 Replacement STEP 2
- Solicitation number
- 23-1128-ITB-C STEP 2
- Issued by
- Pinellas County, Clewiston City, Florida
About this file
This document is a Florida Trench Safety Act Certification and Disclosure Statement, which establishes requirements for excavation and trench safety standards for contractors working in Florida. The document outlines compliance obligations with federal excavation safety standards (29 C.F.R. Section 1926.650 Subpart P) and state-specific trench safety regulations. Contractors are required to consider geotechnical data, design appropriate safety systems, and disclose trench safety measures, including linear feet of trench excavation and associated costs.
The form requires contractors to acknowledge that the disclosed costs for trench safety measures do not fully represent the extent of their compliance obligations. The County's acceptance of the bid does not validate the adequacy of the proposed safety costs, and contractors remain solely responsible for meeting all applicable trench safety requirements. The document provides a table for contractors to detail specific trench safety measures, units of measure, quantities, unit costs, and extended costs, with a warning that failure to complete the form may result in the bid being declared non-responsive.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLORIDA TRENCH SAFETY
FLORIDA TRENCH SAFETY ACT
CERTIFICATION AND DISCLOSURE STATEMENT
The undersigned acknowledges the requirements of the Florida Trench Safety Act (Section 553.60 et. seq. Florida Statutes).
A. The Bidder further acknowledges that the Florida Trench Safety Act, (the Act) establishes the Federal excavation safety standards set forth at 29 C.F.R. Section 1926.650 Subpart P, as the interim state standard until such time as the state of Florida, through its Department of Labor and Employment Security, or any successor agency, adopts, updates, or revises said interim standard. This State of Florida standard may be supplemented by special shoring requirements established by the State of Florida or any of its political subdivisions.
B. The Bidder, as Contractor, shall comply with all applicable excavation/trench safety standards.
C. The contractor shall consider the geotechnical data available from the County, if any, the Contractor's own sources, and all other relevant information in its design of the trench safety system to be employed on the subject Project. The Contractor acknowledges sole responsibilities for the selection of the data on which it relies in designing the safety system, as well as for the system itself.
D. The amounts that the Bidder has set forth for pipe installation includes the following excavation/trench safety measures and the linear feet of trench excavated under each safety measure. These units, costs, and unit values shall be disclosed solely for the purpose of compliance with procedural requirements of the Act. No adjustment to the Agreement Time or price shall be made for any difference in the actual number of linear feet of trench excavation, except as may be otherwise provided in these Contract Documents.
Trench Safety Measure (Description)
Units of Measure
(LF, SF)
Unit (Quantity)
Unit Cost
Extended Cost
1. $ $
2. $ $
3. $ $
4. $ $
5. $ $ For Information Only, Not for Payment Purposes $
FLORIDA TRENCH SAFETY
Bidder may use additional sheets as necessary to extend this form. Failure to complete the above may result in the bid being declared non-responsive.
A. The amount disclosed as the cost of compliance with the applicable trench safety requirements does not constitute the extent of the Contractor’s obligation to comply with said standards. The Contractor shall extend additional sums at no additional cost to the County, if necessary, to comply with the Act (except as otherwise be provided).
B. Acceptance of the bid to which this certification and disclosure applies in no way represents that the County or its representatives has evaluated and thereby determined that the above costs are adequate to comply with the applicable trench safety requirements nor does it in any way relieve the Contractor of its sole responsibility to comply with the applicable trench safety requirements.
Company Name
Name and Title
Address: Telephone/Fax
Federal Employee ID NO. (FEIN)
Email of Account Representative
File details come from the government source that posted it. Updated .