This procurement document is an instruction manual for the Notifier FirstCommand NFC-50/100 fire alarm control panel system, a single-channel, 50-watt emergency voice evacuation panel manufactured by Honeywell for use in fire applications, mass notification applications, or combined operations. The manual provides comprehensive technical specifications, installation procedures, programming instructions, and operating guidelines for the NFC-50/100 and its optional components, including audio amplifier modules, circuit expanders, distributed audio amplifiers, remote consoles, and firefighter telephone systems. The panel supports up to 14 field-programmable voice messages, each up to 60 seconds in duration, with integral tone generators and backup amplifier functionality. Installation requires connection to 120 VAC, 60 Hz, 3.5 amps (or 240 VAC, 50 Hz, 2.0 amps for the NFC-50/100E model), with sealed lead acid battery backup capability up to 26 amp-hours. The system integrates with Fire Alarm Control Panels including the FireWarden-100X, FireWarden-100-2, NFS2-640, and NFS-320 via ACS or ANN-BUS serial communication protocols, allowing automatic activation through eight command input circuits or FACP data bus control. All programming is conducted through a web-based utility accessible via Ethernet connection, with password-protected access and role-based console priority settings.
The manual details extensive technical requirements including power supply calculations per NFPA standards (24-hour standby plus 15-minute alarm operation), wiring specifications for power-limited Class 2 circuits, speaker circuit configurations for Style Y (Class B) and Style Z (Class A) operation, and optional 70.7 VRMS conversion capability for compatibility with existing speaker systems. Optional equipment includes the NFC-BDA-25/70V audio amplifier (providing up to 100 watts total output), NFC-CE6 circuit expander (adding three primary and three secondary speaker circuits), distributed audio amplifiers (NFC-50DA, NFC-125DA, NFC-50/100DA) for multi-facility deployments, and remote operator consoles (NFC-LOC, NFC-RPU, NFC-RM). The system provides comprehensive monitoring and fault detection across speaker circuits, amplifiers, data buses, battery systems, and peripheral devices, with individual LED indicators and a 100-event history log. Canadian applications require specific configuration including audio room isolator modules (AIM-1A and RSM-1A) for circuit isolation during alarm conditions. System maintenance requires annual testing per NFPA 72 standards, with the manufacturer recommending professional installation and authorized servicing only to maintain proper operation and compliance with fire protection standards.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Document LS10001-001NF-E Rev: H
1/8/2018 ECN: 18-117
Notifier FirstCommand
NFC-50/100 & NFC-50/100E
Instruction Manual
2 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it is not a substitute for life and property insurance!
An automatic fire alarm system—typically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control panel (FACP) with remote notifica-tion capability—can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire.
An emergency communication system—typically made up of an automatic fire alarm system (as described above) and a life safety communication system that may include an autonomous control unit (ACU), local operating console (LOC), voice communication, and other various interoperable communication methods—can broadcast a mass notification message. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire or life safety event.
The Manufacturer recommends that smoke and/or heat detectors be located throughout a protected premises following the recommendations of the current edition of the National Fire Protection Association Standard 72 (NFPA 72), manufacturer's recommendations, State and local codes, and the recommendations contained in the Guide for Proper Use of System Smoke Detectors, which is made available at no charge to all installing dealers. This document can be found at http:// www.systemsensor.com/appguides/. A study by the Federal Emergency Management Agency (an agency of the United States government) indicated that smoke detectors may not go off in as many as 35% of all fires. While fire alarm systems are designed to provide early warning against fire, they do not guarantee warning or protection against fire. A fire alarm system may not provide timely or adequate warning, or simply may not function, for a variety of reasons:
Smoke detectors may not sense fire where smoke cannot reach the detectors such as in chimneys, in or behind walls, on roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level or floor of a building. A second-floor detector, for example, may not sense a first-floor or basement fire.
Particles of combustion or “smoke” from a developing fire may not reach the sensing chambers of smoke detectors because:
• Barriers such as closed or partially closed doors, walls, chim-neys, even wet or humid areas may inhibit particle or smoke flow.
• Smoke particles may become “cold,” stratify, and not reach the ceiling or upper walls where detectors are located.
• Smoke particles may be blown away from detectors by air out-lets, such as air conditioning vents.
• Smoke particles may be drawn into air returns before reaching the detector.
The amount of “smoke” present may be insufficient to alarm smoke detectors. Smoke detectors are designed to alarm at various levels of smoke density. If such density levels are not created by a devel-oping fire at the location of detectors, the detectors will not go into alarm.
Smoke detectors, even when working properly, have sensing limita-tions. Detectors that have photoelectronic sensing chambers tend to detect smoldering fires better than flaming fires, which have little visible smoke. Detectors that have ionizing-type sensing chambers tend to detect fast-flaming fires better than smoldering fires.
Because fires develop in different ways and are often unpredictable in their growth, neither type of detector is necessarily best and a given type of detector may not provide adequate warning of a fire.
Smoke detectors cannot be expected to provide adequate warning of fires caused by arson, children playing with matches (especially in bedrooms), smoking in bed, and violent explosions (caused by escaping gas, improper storage of flammable materials, etc.).
Heat detectors do not sense particles of combustion and alarm only when heat on their sensors increases at a predetermined rate or reaches a predetermined level. Rate-of-rise heat detectors may be subject to reduced sensitivity over time. For this reason, the rate-of-rise feature of each detector should be tested at least once per year by a qualified fire protection specialist. Heat detectors are designed to protect property, not life.
IMPORTANT! Smoke detectors must be installed in the same room as the control panel and in rooms used by the system for the connection of alarm transmission wiring, communications, signal-ing, and/or power. If detectors are not so located, a developing fire may damage the alarm system, compromising its ability to report a fire.
Audible warning devices such as bells, horns, strobes, speak-ers and displays may not alert people if these devices are located on the other side of closed or partly open doors or are located on another floor of a building. Any warning device may fail to alert peo-ple with a disability or those who have recently consumed drugs, alcohol, or medication. Please note that:
• An emergency communication system may take priority over a fire alarm system in the event of a life safety emergency.
• Voice messaging systems must be designed to meet intelligibility requirements as defined by NFPA, local codes, and Authorities Having Jurisdiction (AHJ).
• Language and instructional requirements must be clearly dis-seminated on any local displays.
• Strobes can, under certain circumstances, cause seizures in people with conditions such as epilepsy.
• Studies have shown that certain people, even when they hear a fire alarm signal, do not respond to or comprehend the meaning of the signal. Audible devices, such as horns and bells, can have different tonal patterns and frequencies. It is the property owner's responsibility to conduct fire drills and other training exercises to make people aware of fire alarm signals and instruct them on the proper reaction to alarm signals.
• In rare instances, the sounding of a warning device can cause temporary or permanent hearing loss.
A life safety system will not operate without any electrical power. If AC power fails, the system will operate from standby batteries only for a specified time and only if the batteries have been properly maintained and replaced regularly.
Equipment used in the system may not be technically compatible with the control panel. It is essential to use only equipment listed for service with your control panel.
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily disabled. For added protection against telephone line failure, backup radio transmission systems are recommended.
The most common cause of life safety system malfunction is inad-equate maintenance. To keep the entire life safety system in excel-lent working order, ongoing maintenance is required per the manufacturer's recommendations, and UL and NFPA standards. At a minimum, the requirements of NFPA 72 shall be followed. Envi-ronments with large amounts of dust, dirt, or high air velocity require more frequent maintenance. A maintenance agreement should be arranged through the local manufacturer's representative. Mainte-nance should be scheduled as required by National and/or local fire codes and should be performed by authorized professional life safety system installers only. Adequate written records of all inspec-tions should be kept.
Limit-D2-2016 http://www.systemsensor.com/appguides/
Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 3
Installation Precautions Adherence to the following will aid in problem-free installation with long-term reliability:
WARNING - Several different sources of power can be con-nected to the fire alarm control panel. Disconnect all sources of power before servicing. Control unit and associated equipment may be damaged by removing and/or inserting cards, modules, or inter-connecting cables while the unit is energized. Do not attempt to install, service, or operate this unit until manuals are read and understood.
CAUTION - System Re-acceptance Test after Software Changes: To ensure proper system operation, this product must be tested in accordance with NFPA 72 after any programming opera-tion or change in site-specific software. Re-acceptance testing is required after any change, addition or deletion of system compo-nents, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadver-tently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified.
This system meets NFPA requirements for operation at 0-49º C/ 32-120º F and at a relative humidity 93% ± 2% RH (noncondens-ing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the sys-tem's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity.
Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27º C/60-80º F.
Verify that wire sizes are adequate for all initiating and indicating device loops. Most devices cannot tolerate more than a 10% I.R.
drop from the specified device voltage.
Like all solid state electronic devices, this system may operate erratically or can be damaged when subjected to lightning induced transients. Although no system is completely immune from light-ning transients and interference, proper grounding will reduce sus-ceptibility. Overhead or outside aerial wiring is not recommended, due to an increased susceptibility to nearby lightning strikes. Con-sult with the Technical Services Department if any problems are anticipated or encountered.
Disconnect AC power and batteries prior to removing or inserting circuit boards. Failure to do so can damage circuits.
Remove all electronic assemblies prior to any drilling, filing, reaming, or punching of the enclosure. When possible, make all cable entries from the sides or rear. Before making modifications, verify that they will not interfere with battery, transformer, or printed circuit board location.
Do not tighten screw terminals more than 9 in-lbs. Over-tighten-ing may damage threads, resulting in reduced terminal contact pressure and difficulty with screw terminal removal.
This system contains static-sensitive components. Always ground yourself with a proper wrist strap before handling any cir-cuits so that static charges are removed from the body. Use static suppressive packaging to protect electronic assemblies removed from the unit.
Follow the instructions in the installation, operating, and pro-gramming manuals. These instructions must be followed to avoid damage to the control panel and associated equipment. FACP operation and reliability depend upon proper installation.
Precau-D1-9-2005
FCC Warning WARNING: This equipment generates, uses, and can radi-ate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interfer-ence to radio communications. It has been tested and found to comply with the limits for class A computing devices pur-suant to Subpart B of Part 15 of FCC Rules, which is designed to provide reasonable protection against such interference when devices are operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to correct the interference at his or her own expense.
Canadian Requirements
This digital apparatus does not exceed the Class A limits for radiation noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Depart-ment of Communications.
Le present appareil numerique n'emet pas de bruits radio-electriques depassant les limites applicables aux appareils numeriques de la classe A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada.
HARSH™, NIS™, and NOTI•FIRE•NET™ are all trademarks; and Acclimate® Plus™, eVance®, FlashScan®, FAAST Fire Alarm Aspiration Sensing Technology®, Honeywell®, Intelligent FAAST®, NOTIFIER®, ONYX®, ONYXWorks®, SWIFT®, VeriFire®, and VIEW® are all registered trademarks of Honeywell International Inc.
Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. Chrome™ and Google™ are trademarks of Google Inc. Firefox® is a registered trademark of The Mozilla Foundation.
©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.
4 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
Software Downloads In order to supply the latest features and functionality in fire alarm and life safety technology to our customers, we make frequent upgrades to the embedded software in our products. To ensure that you are installing and programming the latest features, we strongly recommend that you download the most current version of software for each product prior to commissioning any system.
Contact Technical Support with any questions about software and the appropriate version for a specific application.
Documentation Feedback Your feedback helps us keep our documentation up-to-date and accurate. If you have any comments or suggestions about our online Help or printed manuals, you can email us.
Please include the following information:
• Product name and version number (if applicable)
• Printed manual or online Help
• Topic Title (for online Help)
• Page number (for printed manual)
• Brief description of content you think should be improved or corrected
• Your suggestion for how to correct/improve documentation
Send email messages to:
FireSystems.TechPubs@honeywell.com
Please note this email address is for documentation feedback only. If you have any technical issues, please contact Technical Services.
Table of Contents
Section 1: Product Description 1.1: Product Features 1.2: Input/Output Circuit Specifications
1.2.1: NFC-50/100 Main Control Board 1.2.2: Display Board 1.2.3: NFC-CE6 Circuit Expander Module
1.3: Controls and Indicators 1.3.1: Push-Button Controls 1.3.2: LED Indicators (visible with door closed) 1.3.3: LED Indicators (visible with door and dress panel open)
1.4: Components 1.5: Optional Equipment 1.6: UL 464 Low Frequency Sounders
Section 2: Installation 2.1: Mounting Options 2.2: Backbox Installation
Removing the Dress Panel Removing the Chassis Assembly Mounting the Backbox
2.3: Operating Power 2.3.1: AC Power and Earth Ground Connection 2.3.2: Secondary Power Source (Batteries)
2.4: Auxiliary DC Power Output Connections 2.5: Input/Initiating Circuits
2.5.1: CMD Inputs 2.5.2: External Audio Input 2.5.3: NAC Follower Input 2.5.4: Night Ring
2.6: Output Circuits 2.6.1: Relays
MNS Active Relay - TB1 Trouble Relay - TB2 AC Power Loss Relay - TB3
2.6.2: Speaker Circuits 2.6.3: Notification Appliance Circuit 2.6.4: Speaker Volume Control 2.6.5: FACP Data Bus
NFW-100X
FireWarden-100-2 NFS2-640 and NFS-320 ACS Mode Wiring
2.7: NFC-LOC Local Operator Console 2.8: NFC-RPU Remote Page Unit 2.9: NFC-RM Remote Microphone 2.10: NFC-50DA, NFC-125DA, NFC-50/100DA Distributed Audio Amplifiers 2.11: Shielding for External Device Wiring 2.12: UL Power-limited Wiring Requirements 2.13: Installation of Option Modules
2.13.1: NFC-CE6 Circuit Expander Module 2.13.2: Audio Amplifier Module (NFC-BDA-25/70V)
Installation Power and Control Cables Configuration NFC-50/100 Configurations with NFC-BDA-25/70V
2.13.3: 70.7 VRMS Transformer (NFC-XRM-70V) 2.14: Addressing External Data Bus Devices
Section 3: Programming 3.1: NFC-50/100 Panel Installation/Maintenance Security Checklist 3.2: Main Menu - User Programming
3.2.1: Password Options Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 5
3.2.2: General/NAC Options General Options NAC Options Console Control
3.2.3: Address Assignment Remote Microphone / Operator Console Address Assignments Speaker Circuit Address Assignment
3.2.4: Message Buttons Message Buttons CMD Input Style
3.2.5: Date / Time 3.2.6: Send to Panel
3.3: Main Menu - Utilities 3.3.1: Message Recording 3.3.2: USB File Options
3.4: Main Menu - Informational 3.4.1: Informational
Speaker Circuit Buttons Version Information History Information
3.5: Recording Custom Messages 3.5.1: Message Record Mode 3.5.2: External Audio Input
Recording with External Audio - Example 3.5.3: Microphone
Recording with Microphone - Example 3.5.4: Erasing a User Message 3.5.5: Voice Loader Software
Writing a Message to the Panel Reading a Message from the Panel Moving a Message to a Different Slot
3.6: Programmed Activation by FACP 3.6.1: FireWarden-100X and FireWarden-100-2
FACP Programming FACP Message Assignment - Speaker Specific FACP Message Assignment - Zone Specific FACP Programming Menus
3.6.2: NFS2-640 and NFS-320 FACP Programming
Section 4: Operating Instructions 4.1: Main Control Panel Keypad Labels 4.2: NFC-50/100 Switch Functions 4.3: LED Indicators 4.4: Operation
4.4.1: Paging from the Microphone 4.4.2: Manual Message Control 4.4.3: Fire Alarm Response, System Configured for Fire Only 4.4.4: Fire Alarm Restoral, System Configured for Fire Only 4.4.5: Manual Activation 4.4.6: Manual Activation Restoral 4.4.7: Alarm/Alert Response, System Configured for Mass Notification Only 4.4.8: Alarm/Alert Restoral, System Configured for Mass Notification Only 4.4.9: Alarm/Alert Response, System Configured for Combo Fire/Mass Notification with Fire Priority 4.4.10: Alarm/Alert Restoral, System Configured for Combo Fire/Mass Notification with Fire Priority 4.4.11: Alarm/Alert Response, System Configured for Combo Fire/Mass Notification with Mass Notification Priority 4.4.12: Alarm/Alert Restoral, System Configured for Combo Fire/Mass Notification with Mass Notification Priority 4.4.13: Trouble Condition Response 4.4.14: Trouble Condition Restoral 4.4.15: External Audio Input Operation
Section 5: Getting Started 5.1: System Requiring up to 50 Watts of Audio Power 6 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
5.2: System Requiring Up to 100 Watts of Audio Power 5.3: System Requiring Greater Than 100 Watts of Audio Power
Section 6: Power Supply Calculations 6.1: Overview 6.2: Calculating the AC Branch Circuit 6.3: Calculating the System Current Draw
6.3.1: Overview 6.3.2: How to use Table 6.2 to calculate system current draws
6.4: Calculating the Battery Size 6.4.1: NFPA Battery Requirements 6.4.2: Selecting and Locating Batteries
Appendix A: Digital Voice Messages
Appendix B: Wiring Requirements
Appendix C: Canadian Applications C.1: Audio Room Isolator Modules
C.1.1: Description C.1.2: Panel Programming C.1.3: Applications
Slide-in Labels - Upper Portion
Slide-in Labels - Lower Section
Index
NFC-50/100 and NFC-LOC OPERATING INSTRUCTIONS Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 7
This control panel has been designed to comply with standards set forth by the following regulatory agencies:
• Underwriters Laboratories/Underwriters Laboratories Canada
• National Fire Protection Association
NFPA Standards
This Fire Alarm Control Panel complies with the following NFPA Standards:
NFPA 72 National Fire Alarm Code
Note: Audible signal appliances used in public mode applications, are required to have minimum sound levels of 75 dBA at 10 feet (3 meters) and a maximum level of 120 dBA at the minimum hearing distance from the audible appliance.
To ensure that the appliance is clearly heard, the audible appliance sound level must be at least 15 dBA above the average ambient sound level or 5 dBA above the maximum sound level with a duration of at least 60 seconds, depending on which level is greater, with the sound level being measured 5 feet (1.5 meters) above the floor.
Underwriters Laboratories Documents:
UL 38 Manually Actuated Signaling Boxes
UL 464 Audible Signaling Appliances
UL 864 Standard for Control Units for Fire Protective Signaling Systems
UL 1480 Speakers for Fire Protective Signaling Systems
UL 1638 Visual Signaling Appliances
UL 1711 Amplifiers for Fire Protective Signaling Systems
UL 1971 Signaling Devices for Hearing Impaired
UL 2572 Communication and Control Units for Mass Notification Systems
CAN/ULC - S524-01 Standard for Installation of Fire Alarm Systems
CAN/ULC - S527-11 Standard for Control Units for Fire Alarm Systems
This Class (A) digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe (A) est conforme à la norme NMB-003 du Canada.
Other:
Canadian Electrical Code, Part 1
NEC Article 250 Grounding
NEC Article 300 Wiring Methods
NEC Article 760 Fire Protective Signaling Systems
Applicable Local and State Building Codes
Requirements of the Local Authority Having Jurisdiction (LAHJ)
Notifier Documents:
Notifier Device Compatibility Document Document #15378
NFC Distributed Audio Manual Document #LS10027-001NF-E
NFC-FFT Manual Document #LS10031-001NF-E
NFC-LOC Installation Document Document #LS10028-001NF-E
NFC-RPU Installation Document Document #LS10030-001NF-E
NFC-RM Installation Document Document #LS10029-001NF-E
NFC-CE6 Installation Document Document #LS10033-001NF-E
NFC-CE4 Installation Document Document #LS10002-001NF-E
NFC-BDA-25/70V Installation Document Document #LS10035-001NF-E
NFC-XRM-70V Installation Document Document #LS10032-001NF-E
NFW-100X Manual Document #LS10131-001NF-E
NFS2-640 Listing Document Document # 52741LD
NFS-320 Listing Document Document # 52745LD
FireWarden-100-2 Series Manual Document #52778
Before proceeding, the installer should be familiar with the following documents.
8 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
Speaker Circuits
TB20 & TB21
internal options
NFC-BDA-25/70V
optional amplifier
NFC-CE6
circuit expander
NFC-50DA
50W remote amplifier
NFC-RPU
remote page unit
NFC-RM
remote microphoneremote consoles distributed audio
NFC-125DA
125W remote amplifier
NFC-LOC
local operator console
CHG-120
charger
CHG-75
charger external battery charger - J7
TB24
TB12
TB22
nf cp er i.w m f
NAC Circuit
TB19
visual only
NFC-FFT
firefighter telephone
NFC-50/100DA
50/100W remote amplifier Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 9
J1
TB
J9 R
TZ
M
DI
SP
LA
Y
C A
U T
IO
N
H
IG
H
V O
LT
A
G E ec c5
0l ay o.
w m f
A C
P o w er
(S up er vi se d, N on po w er -L im ite d)
VA
C , 6
H z, .5 a m ps or
VA
C
, 5
H z, .0 a m ps
S p ec ia l A p p lic at io n
D C
P o w e r O u tp u t
(2
V D
C
S up er vi se d, P ow er -L im ite d (C la ss
) c irc ui t Su pe rv is e w ith a p ow er s up er vi si on re la y E
O
LR
-1 N on re se tta bl e
P ow er s ui ta bl e fo r p ow er in g co nt ro l m od ul es a nd p ow er s up er vi si on re la ys
N A
C F o llo w er
I n p u t Su pe rv is ed
, P ow er
Li m ite d
(C la ss ci rc ui ts
V D
C fi lte re d (1 m
A m ax im um
R eq ui re s an
F
AC
P E nd -o f-L in e R es is to r
A C
L o ss , M
N S
A c ti v e, F ix e d
T ro u b le R el a y N on -s up er vi se d re la y co nt ac ts
C on ta ct ra tin g:
2.
am ps
V D
C (r es is tiv e)
0.
am ps
V
AC
(r es is tiv e)
C on ta ct s sh ow n be lo w in no rm al c on di tio n (A
C p ow er ith n o al ar m
, t ro ub le
, o r su pe rv is or y ac tiv ity
Fa il
Sa fe
T ro ub le re la y sw itc he s to th e
N O p os iti on du rin g tro ub le c on di tio ns a nd un de r l os s of a ll po w er
Fl as h M em or y Lo ad E na bl e S w itc h:
U
P is n or m al po si tio n fo r s w itc h, D O
W po si tio n al lo w s fo r f ac to ry so ftw ar e up gr ad es
E th er ne t P or t J 2/ fo r l oc al p ro gr am m in g us in g a pe rs co pu te r a nd w eb ba se d ut ilit y
B at te ry
V
D C
, s up er vi se d, -p ow er
-li m ite d, A
H m ax im um
N o ti fi c at io n
A p p lia n ce C ir cu it St yl e
Y (C la ss
B ) o r St yl e
Z (C la ss
A
Su pe rv is ed , P ow er
Li m ite d (C la ss
(S pe ci ap pl ic at io n)
.0 am ps m ax
R eg ul at ed p ow er
0m
A m ax
E
LR
, 4 .7
K , 1
/2 W
(fo r S ty le
Y w iri ng
O pt io na l 5 0W
A m pl ifi nn ec to rs
O pt io na l 7 0V
Tr an sf or m er c on ne ct or
O pt io na l C E
C irc ui t E xp an de r C on ne ct or
D is pl ay
B oa rd nn ec to r
S p ea ke r V o lu m e
C o n tr o l O ve rr id e
S ty le Y
(C la ss B
) o r S ty le
Z (C la ss
A
Su pe rv is ed , P ow er
-L im ite d
(C la ss
(S pe ci al a pp lic at io n)
.2 am ps m ax
4.
7K Ω
E
LR
, 1 /2
W re qu ire d fo r S ty le Y
(C la ss
B ) w iri ng
P ri m ar y/ S ec o n d ar y
S p ea ke r C ir cu it s
S ty le Y
(C la ss B
) o r S ty le
Z (C la ss
A
S up er vi se d, P ow er -L im ite d (C la ss
W in te gr at ed o ut pu t p ow er . U se o f se co nd ar y ci rc ui t r eq ui re s op tio na l
N
FC
-B D
A-
/7 0V a m pl ifi er
K Ω
E
LR
, 1 W re qu ire d fo r S ty
Y
(C la ss B
) w iri ng
C M
D
C
M D
C o m m an d In p u t C ir cu it s
Tr ig ge r b y co nt ac t c lo su re o r N
A C re ve rs e po la rit y
(E
LR
re qu ire d fo r m es sa ge s) al ar m p ol ar ity s ho w n.
C M
D
C
M D
C o m m an d In p u t C ir cu it s
Tr ig ge r b y co nt ac t c lo su re
(E
LR
re qu ire d fo r m es sa ge s) a la rm p ol ar ity s ho w n.
(in pu ts o nl y)
N ig h t
R in g In p u t Tr ig ge r b y co nt ac t c lo su re
E xt er n a l O p e ra to r In te rf a ce
P o w e r S up er vi se d, P ow er
-L im ite d
(C la ss
) c irc ui t
V
D C
N on re se tta bl e P ow er fo r ex te rn al o pe ra to r i nt er fa ce c om po ne nt s.
E x te A rn al
D a ta B u s
S up er vi se d, P ow er -L im ite d (C la ss
) d at a co nn ec tio ns ex te rn al o pe ra to r i nt er fa ce po ne nt s
F A
C P
D at a B u s
S up er vi se d, P ow er -L im ite d ci rc ui t d ed ic at ed a s
FA
C P se ria l b us c on ne ct io n
E xt er n al A u d io R is er
S ty le Y
(C la ss B
) o r S ty le
Z (C la ss
A
S up er vi se d, P ow er -L im ite d (C la ss au di o co nn ec tio n to e xt er na l o pe ra to r in te rfa ce c om po ne nt s
S pe ak
Vo lta ge
S itc h S
W
To d is ab gr ou nd fa ul t de te ct n, re ov e ju m pe r/s hu nt fro
J
S 2.
N
FC
-5 0/
Tr ou bl e
LE
D s.
S ee
Se ct io n 1.
3.
on p ag e fo r m or e in fo rm at n.
B as ic S ys te m C o n n ec ti o n s
M ai n
C o n tr o l B o ar d
S ec ti o n 1.
2.
C ut ju m pe r t o us e ex te rn al c ha rg er
B ac ku p am pl ifi te st s w itc h S
W
S et s w itc h or m al
(d ow n po si tio n)
U
SB
-A P or t J
1/ fo r l oc al p ro gr am do nl oa d
10 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
TB5- External Audio Input/ Audio Riser
SW1- Dipswitch for BUS addressing Must be set to address 2.
ON
JP5 -
isolation/ground when powered by source other than main control board
J2- Connection to main control board
P2- Microphone connector
J1- USB connector -connection to a PC for downloading messages
Refer to Section 3.5.5 on page 63.
Basic System Connections - Display Board (Section 1.2.2) di sp .w m f
SW2- Distributed Audio Switch set to UP position if any NFC-50/125DAs are installed in the system.
Default is the DOWN position.
JP2 - External Data Bus termination Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 11
Section 1: Product Description The Notifier FirstCommand NFC-50/100 is a single channel, 50 watt, 25 VRMS, emergency voice evacuation panel that may be used for fire applications, mass notification applications, or both. The NFC-50/100 comes standard with one speaker circuit. The panel provides the ability to record fourteen field programmable messages (up to 60 seconds each) with an integral microphone or from an external audio source. An integral power supply with battery charger supplies operational power. A 50 watt audio amplifier is built into each panel. An optional second 50 watt amplifier (NFC-BDA-25/70V) is also available for backup purposes or to provide an additional 50 watts. The backup amplifier is available in either 25 volts or 70 volts depending on which application is necessary.
Automatic activation of the NFC-50/100 by an FACP is possible via eight Command Input Circuits (CMD) or via the ACS/ANN Bus serial communications link from the FireWarden-100X, FireWarden-100-2, NFS2-640, and NFS-320 FACPs.
Two Command Input Circuits can be independently field programmed for activation by an FACP Notification Appliance Circuit reverse polarity or by closure of a supervised normally open contact and six Command Input Circuits activate on contact closure. CMD 1 and CMD 2 provide terminals for NAC input and output to allow installation of the audio panel anywhere along the NAC circuit being used to activate it.
If the message generator fails, the system automatically reverts to a backup tone generator.
Power is fed independently to each amplifier so that a short circuit in one amplifier will not shut down the other. Full output power of 50 watts per amplifier is generated while in a low battery condition. Power is not diminished when the optional 70 VRMS transformer mod-ule is installed. Audio is amplified utilizing modern integrated circuits as opposed to transformer technology. This provides for very low signal distortion for crystal clear audio.
Primary applications for the audio panels include protecting structures such as military facilities, restaurants, schools, auditoriums, places of worship, buildings with occupancies over 50, etc. The NFC-50/100 is designed to interface directly to addressable or conven-tional (CMD inputs 1-8) fire alarm control panels or can be used with the NFC-50/125DA panel to distribute audio in systems that require more than 100 watts.
For Canadian applications, refer to Appendix C on page 83.
1.1 Product Features
• Modular design for maximum system flexibility and easy expansion
• Removable terminal blocks for ease of servicing and module replacement
• 50 watts of 25 VRMS audio power (expandable to 100 watts)
• 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for protocols:
– System Sensor
– Wheelock
– Gentex
• Optional 70.7 VRMS conversion transformer available for the primary amplifier (note that speaker wiring continues to be supervised in standby, alarm and when background music is playing with this optional transformer installed)
• Eight Command Input Circuits to activate messages 1 to 8:
– CMD1 and CMD2 are field selectable to be activated from 12 or 24 VDC Notification Appliance Circuits (reverse polarity) or contact closures
– CMD3-CMD8 are activated by contact closures
• Speaker Circuits
– single Style Y (Class B) or Style Z (Class A) speaker circuit
– two Style Y (Class B) or Style Z (Class A) speaker circuits (with optional NFC-BDA-25/70V Audio Amplifier installed)
– eight Style Y (Class B) or Style Z (Class A) speaker circuits (with optional NFC-BDA-25/70V and NFC-CE6 installed)
• NFC-50/100 can be controlled by an FACP via the ANN/ACS (EIA-485) link. ACS compatible FACPs include the FireWarden- 100X, FireWarden-100-2, NFS2-640, and NFS-320. ANN compatible FACPs include the FireWarden-100-2.
• Integral supervised microphone
• Microphone time-out feature which reverts back to prerecorded message if emergency page exceeds the programmed time
• Up to 14 recorded messages
• 14 prerecorded messages for fire, emergency, and weather alerts
• Field-selectable message and custom message recording capability using the local microphone, a USB port, or an external audio input
• External Audio Input can be used for background music
• Up to 60 second message duration for all messages
• Integral tone generators field selectable for multiple tone types
• Powered by integral AC power supply or batteries during AC fail
• Programmable delay of immediate, 2 hours or 6 hours reporting of AC Loss
• Piezo sounder for local trouble
• 100 event history log
• Three Form-C relays:
– AC Power Loss Relay - TB1
– System Trouble Relay - TB2
– MNS Active - TB3
• 500 mA (0.5A) Special Application (auxiliary power) output for addressable modules when interfaced with compatible addressable FACPs and End-of-Line power supervision relays 12 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
Input/Output Circuit Specifications Product Description
• System Status LEDs (refer to “Controls and Indicators” on page 17)
• Integral Dress Panel
• Optional TR-CE-B semi-flush trim ring
• Any combination of up to eight (8) of:
– Optional NFC-RM Remote Microphone (includes cabinet).
– Optional NFC-RPU Remote Page Unit (includes cabinet)
– Optional NFC-LOC (includes cabinet)
• Optional NFC-CE6 Circuit Expander
• Optional NFC-BDA-25V amplifier, 50 watts, 25 volts
• Optional NFC-BDA-70V amplifier, 50 watts, 70 volts
• Optional NFC-50DA distributed amplifier, 50 watts
• Optional NFC-125DA distributed amplifier, 125 watts
• Optional NFC-50/100DA distributed amplifier, 50/100 watts
1.2 Input/Output Circuit Specifications
1.2.1 NFC-50/100 Main Control Board
AC Power - TB15
NFC-50/100: 120 VAC, 60 Hz, 3.5 amps (HOT, NEU) NFC-50/100E: 240 VAC, 50 Hz, 2.0 amps (HOT=HotLeg1, NEU=HotLeg2) Wire size: minimum #14 AWG (2.00mm2) with 600 V insulation.
Battery (lead acid only) - J7
Maximum Charging Circuit: Normal Flat Charge - 27.3V @ 2.8 amps Maximum Charger Capacity: 26 Amp Hour battery. (NFC cabinet holds max. 18 Amp Hour Battery.
Minimum Battery Size: 12 Amp Hour
MNS Active Relay - TB1
Form-C relay contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive), Form-C Trouble Relay - TB2
Form-C relay contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amp @ 30 VAC (resistive).
AC Loss Relay - TB3
Form-C relay contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive), NAC Output - TB19, Terminals 1 (B+), 2 (A+), 3 (A-), & 4 (B-)
One (1) Style Y (Class B) or Style Z (Class A) circuit Power-limited circuitry (Class 2), supervised Nominal operating voltage: 24 VDC Maximum signaling current for special application power: 2.0 amps Maximum signaling current for regulated power: 200mA Current limit: fuseless, electronic, power-limited Maximum wiring impedance: 1 Ω End-Of-Line Resistor: 4.7 KΩ, ½ watt, (P/N 71252) required for Style Y (Class B) operation Refer to the Device Compatibility Document for listed compatible devices.
NAC Follower - TB18, Terminals 3 (IN+), 4 (IN-), 1 (OUT+) & 2 (OUT-)
Connections for FACP NAC synchronization trigger signal Output terminals: pass-through to other system components Trigger input voltage: 9 to 32 VDC, 24 VDC rated Input current draw in Alarm condition: 10 mA at rated voltage
Special Application Power (Aux. Power) - TB17 Terminals 1(+) & 2(-)
Up to 500 mA @ 24 VDC of special application power is available for powering addressable modules and associated End-of-Line power supervision relays.
Power-limited (Class 2) circuitry. Refer to the Device Compatibility Document for a list of compatible devices.
Speaker Volume Control Override - TB23, Terminals 1 (B+), 2 (A+), 3 (A-), & 4 (B-)
Style Y (Class B) or Style Z (Class A) circuit Special Application power Power-limited (Class 2) circuitry, supervised Nominal operating voltage: 24 VDC Maximum signaling current: 0.25 amps Current limit: fuseless, electronic, power-limited End-Of-Line Resistor: 4.7 KΩ, ½ watt, (P/N 71252) required for Style Y (Class B) operation Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 13
Product Description Input/Output Circuit Specifications Speaker Circuits
Primary Speaker Circuit - TB20, Terminals 1(+) & 2(-) Style Y (Class B), 4(+) & 5(-) Style Z (Class A), 3 Shield (Standby and Alarm Polarity Shown) on main control board
Secondary Speaker Circuit (with optional amplifier only) - TB21, Terminals 1(+) & 2(-) Style Y (Class B), 4(+) & 5(-) Style Z (Class A), 3 Shield (Standby and Alarm Polarity Shown) on main control board
Power-limited (Class 2) circuitry Operation: Circuit can be wired Style Y (Class B) or Style Z (Class A) Normal Operating Voltage: 25 VRMS @ 2 amps max. and maximum Load Impedance of 12.5Ω (70.7 VRMS @ 700 mA max. with maximum Load Impedance of 100Ω operation possible by plugging optional NFC-XRM-70V conver-sion transformer into J12 of the main control board).
Output Power: 50 watts, standard; 100 watts with optional amplifier (100 watts total, maximum, allowed in standby for background music) Frequency Range: 800 - 2,800 Hz Maximum total capacitance for each speaker circuit: 250 µF.
End-of-Line Resistor required for Style Y circuit: 15 KΩ, 1 watt (P/N: ELR-15K)
Command Input Circuits (alarm polarities shown)
• CMD1 - TB4 Terminals 3(+) & 4(-) are input terminals and Terminals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices downstream; provides internal trouble relay rated at 3.0 amps maximum
• CMD2 - TB5 Terminals 3(+) & 4(-) are input terminals and Terminals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices downstream
• CMD3 - TB6 Terminals 1(+) & 2(-) are input terminals for contact closure only
• CMD4 - TB6 Terminals 3(+) & 4(-) are input terminals for contact closure only
• CMD5 - TB7 Terminals 1(+) & 2(-) are input terminals for contact closure only
• CMD6 - TB7 Terminals 3(+) & 4(-) are input terminals for contact closure only
• CMD7 - TB8 Terminals 1(+) & 2(-) are input terminals for contact closure only
• CMD8 - TB8 Terminals 3(+) & 4(-) are input terminals for contact closure only Power-limited (Class 2) and supervised circuitry Normal Operating Voltage Range: 10.5 VDC - 29 VDC; Maximum Voltage: 29 VDC NAC Reverse Polarity Current (requires End-of-Line Resistor from NAC): 1.6 mA maximum.
Contact Closure Operation Current (requires 4.7K, ½ watt End-of-Line Resistor P/N 27072 only when messages have been assigned to the command input): 6.6 mA maximum Maximum Wiring Impedance CMD1 - CMD8 (Contact Closure Operation): 200Ω Maximum Input Impedance:
• CMD1 & CMD2 (Reverse Polarity Operation): 20KΩ
• CMD1 - CMD8 (Contact Closure Operation): 4.75KΩ
Night Ring Input - TB16, Terminals 1 (+) & 2 (-)
Contact closure input Isolated, nonsupervised Operation current: 3.8 mA, maximum Maximum wiring impedance: 30K Ω Minimum isolation withstand voltage: 1500 VRMS
External Operator Interface Power Output - TB24, Terminals 1 (PWR, +) & 2 (GND, -)
Non-resettable power for external operator interface components Power-limited (Class 2) circuitry, Supervised Nominal operating voltage: 24 VDC Maximum output current: 0.80 amps Current limit: fuseless, electronic, power-limited circuitry
External Data Bus (EIA-485) - TB12, Terminals 2 (B), 3 (A), 4 (BRTN), 5 (ARTN), & 1 (SHLD)
Data connections for external operator interface components Redundant transceiver circuitry for Class A operability Power-limited (Class 2) circuitry, supervised Maximum wiring impedance: 13.2 Ω
FACP Data Bus (EIA-485) - TB13, Terminals 1 (B IN), 2 (A IN), 3 (B OUT), & 4 (A OUT)
Dedicated connection to FACP serial bus Output terminals: pass-through to other system components Isolated, supervised Minimum isolation withstand voltage: 1500 VRMS Maximum wiring impedance: 40 Ω (ANN-BUS)/26 Ω (ACS BUS) 14 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
Input/Output Circuit Specifications Product Description External Audio Riser TB22, Terminals 1 (OUT+), 2 (OUT-), 4 (IN+), 5 (IN-), & 3 (SHLD)
Style Y (Class B) or Style Z (Class A) audio connections to external operator interface components Power-limited (Class 2) circuitry, supervised Audio signal level: 3.85 VRMS, maximum Frequency range: 800 - 2,800 Hz Frequency range (NFC-50/125DA): 800 Hz - 2.8 KHz
Current Availability
The following figures illustrate the maximum current allowed for each output circuit in the panel and the total output current available from the power supply. Refer to Section 6, “Power Supply Calculations” for additional current draw by option cards that must be consid-ered when determining total standby and alarm currents.
NOTE: Zero impedance to ground will cause a ground fault.
TB20
TB21
TB19
TB24
TB23
TB17
Primary 50W Speaker Circuit 50W max = 3.3 amps from supply
Secondary 50W Speaker Circuit- Optional Amplifier Installed
NAC Circuit 2.0 amps max.
Aux. Power 0.5 amp max.
Speaker Volume Control Override
0.25 amp max.
External Operator Interface Power 0.8 amp max.
Alarm
7.5 amps max.
Figure 1.1 Current Availability - 100 Watt System
TB20
TB21
TB24
TB17
50W max = 3.3 amps from supply
Primary 50W Speaker Circuit
Secondary 50W Speaker Circuit-
Optional Amplifier Installed
Aux. Power
External Operator Interface Power combined 10W max = 0.66 amps from supply
0.5 amp max.
0.8 amp max.
Standby
2.0 amps max.
(includes background music).
Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 15
Product Description Input/Output Circuit Specifications
1.2.2 Display Board
External Audio Input - TB5, Terminals 1(-), 2 (+)
Input Impedance: 8.5KΩ, nominal @ 1 KHz Input Voltage: 700 mVRMS maximum Input Current: 0.1 mA, maximum @ 700 mV Background Music Input Voltage (Non-Canadian applications): 225mVRMS, maximum
1.2.3 NFC-CE6 Circuit Expander Module
Power-limited (Class 2) circuitry Up to six (6) circuits on the NFC-CE6 can be wired as Style Y (Class B) or Style Z (Class A).
Normal Operating Voltage for Speaker Circuits: 25 VRMS @ 2 amps max. and maximum Load Impedance of 12.5Ω
(70.0 VRMS @ 700 mA max. with maximum Load Impedance of 100Ω operation possible for the primary circuit by plugging optional NFC-XRM-70V conversion transformer into J12 of the main control board. The same operation is possible for the optional 50W amplifier by selecting the NFC-BDA-70V model.)
Speaker circuit wiring is supervised during standby, background music, and alarm.
Output Power: 50 watts total; Frequency Range: 800 - 2,800 Hz Maximum total capacitance: 250 µF. (Note that the total capacitance for the speaker outputs must not exceed the maximum of 250 µF).
End-of-Line Resistor required for Style Y (Class B) speaker circuit: 15 KΩ, 1 watt (P/N: ELR-15K) TB13 on the main control board: ACS/ANN (EIA-485) electrically isolated link to FACP provides programmed speaker control
TB20
TB19
TB17
TB23
TB24
TB20
TB17
TB24
Primary 50W Speaker Circuit
10W max. = 0.66 amps from supply
NAC Circuit 2.0 amps max.
Aux. Power 0.5 amp max.
Speaker Volume Control Override
0.25 amp max.
External Operator Interface Power 0.8 amp max.
Standby
2.0 amps max.
(includes background music).
Alarm
7.5 amps max.
Figure 1.2 Current Availability - 50 Watt System
Primary 50W Speaker Circuit
10W max. = 0.66 amps from supply
Aux. Power 0.5 amp max.
External Operator Interface Power 0.8 amp max.
NOTE: Some laptops/personal computers only provide an audio output for headphones. It may be necessary to adjust the headphone output level for proper recording of voice messages.
16 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
Controls and Indicators Product Description
1.3 Controls and Indicators
1.3.1 Push-Button Controls
• All Call
• MNS Control
• System Control
• Speaker Select 1-24
• Message Select 1-8
• Diagnostic Select
• Trouble Silence
• Console Lamp Test
1.3.2 LED Indicators (visible with door closed)
• Fire System Active (green)
• MNS Control (green)
• System Control (green)
• System in Use (green)
• Speaker Zone 1-24 Active (green)
FIRE SYSTEM
ACTIVE SYSTEM
CONTROL
ALL
CALL
ec ck yd .w m f
Figure 1.3 NFC-50/100 Keypad
MNS
CONTROL
green green yellow yellow red green green yellow
Note: Console assignments are shown here as an example only.
SPEAKER
ZONE 1
SPEAKER
ZONE 2
SPEAKER
ZONE 3
SPEAKER
ZONE 4
SPEAKER
ZONE 5
SPEAKER
ZONE 6
SPEAKER
ZONE 7
SPEAKER
ZONE 8
SPEAKER
ZONE 9
SPEAKER
ZONE 10
SPEAKER
ZONE 11
SPEAKER
ZONE 12
SPEAKER
ZONE 13
SPEAKER
ZONE 14
SPEAKER
ZONE 15
SPEAKER
ZONE 16
SPEAKER
ZONE 17
SPEAKER
ZONE 18
SPEAKER
ZONE 19
SPEAKER
ZONE 20
SPEAKER
ZONE 21
SPEAKER
ZONE 22
SPEAKER
ZONE 23
SPEAKER
ZONE 24
MESSAGE 1
MESSAGE 2
MESSAGE 3
MESSAGE 4
MESSAGE 5
MESSAGE 6
MESSAGE 7
MESSAGE 8
OK TO PAGE
MICROPHONE
TROUBLE
DIST. AMP 1
DIST. AMP 2
DIST. AMP 3
DIST. AMP 4
DIST. AMP 5
DIST. AMP 6
DIST. AMP 7
DIST. AMP 8
DIAGNOSTIC
REMOTE AMPS
TROUBLE SILENCE
AC POWER
GROUND FAULT
CHARGER FAULT
BATTERY FAULT
DATA BUS FAULT
NAC FAULT
NAC ACTIVE
SYSTEM TROUBLE
AUDIO RISER FAULT
LOC 1
LOC 2
RPU 1
RPU 2
RPU 3
RM 1
RM 2
RM 3
CONSOLE LAMP TEST
MAIN CONSOLE
Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 17
Product Description Components
• Speaker Zone 1-24 Fault (yellow)
• OK to Page (green)
• Microphone Trouble (yellow)
• Message 1-8 Active (red)
• Message 1-8 Fault (yellow)
• Remote Amplifier 1-8 Fault (yellow)
• LOC/RPU/RM 1-8 Fault (yellow)
• LOC/RPU/RM 1-8 Active (green)
• Main Console Fault (yellow)
• AC Power (green)
• Ground Fault (yellow)
• Charger Fault (yellow)
• Battery Fault (yellow)
• Data Bus Fault (yellow)
• NAC Fault (yellow)
• NAC Active (green)
• System Trouble (yellow)
• Audio Riser Fault (yellow)
1.3.3 LED Indicators (visible with door and dress panel open)
• MCB Trouble (yellow)
– Integral 50W amplifier electronics fault
• Option Card Trouble (yellow)
– NFC-CE6 card missing
– NFC-BDA-25/70V card missing
– NFC-BDA-25/70V electronics fault
• Amplifier Over Current Fault (yellow)
– Missing or incorrect EOL resistor
– Short circuit on volume control module
1.4 Components
Main Control Board
The NFC-50/100 main control board contains the system's CPU, power supply, battery charger, other primary components and wiring interface components. One 50W amplifier is integrated into the main control board.
Display Board
The display board contains the user interface along with tone generators, digital message recorder/generator, integral microphone input, and preamplifier.
18 Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018
Components Product Description Cabinet
The cabinet is black with an attractive grey front overlay. A clear window allows viewing of the display board, status LEDs and location of microphone. The backbox measures 16.65" x 19.0" x 5.2" D (42.29cm x 48.26cm x 13.23cm) and provides space for two 12AH or two 18AH batteries.
Batteries
The cabinet provides space for up to 18 Amp Hour batteries (charged by integral Power Supply/Battery Charger) with all options installed.
Dress Panel
The Dress Panel is supplied standard with the system. It mounts to the cabinet with two supplied screws. The Dress Panel protects the user from high voltages and circuit boards from accidental damage.
Trim Ring
An optional TR-CE-B trim ring is available for semi-flush mounting of the audio panel.
Figure 1.4 Cabinet nf cf ro nt
.w m f
Figure 1.5 Dress Panel ec c_ dp .w m f
Notifier FirstCommand Series Manual — P/N LS10001-001NF-E:H 1/8/2018 19
Product Description Optional Equipment
1.5 Optional Equipment
NFC-BDA-25/70V Audio Amplifier Modules
An optional second audio amplifier can be plugged into connectors J10 & J11 located in the upper right of the main control board in the NFC-50/100. This amplifier also provides 50 watts of power at 25 VRMS or 70 VRMS, depending on the model, and can therefore be used to expand system power to 100 watts (providing dual 50 watt speaker circuits) or it can be used as a backup amplifier. The output is power-limited (Class 2) and speaker circuit connections to it are provided on the main control board and optional speaker circuit expander module. The circuit can be wired for Style Y (Class B) or Style Z (Class A) operation.
LEDs are provided to indicate Amplifier Supervision (green indicates amplifier is functional) and Circuit Trouble (yellow indicates field wiring fault or amplifier fault). The LEDs are only visible with the panel door open.
NFC-CE6 Circuit Expander Module
This optional module plugs into connector P1 in the upper middle of the main control board. The NFC-CE6 adds three primary speaker circuits to the NFC-50/100. The NFC-CE6 adds three secondary circuits to the system when the NFC-BDA-25/70V Audio Amplifier Module is also installed.
NFC-XRM-70V Transformer 70.7 VRMS
This optional module plugs into connector J12 of the main control board and provides conversion for the integral audio amplifier from 25 VRMS to 70.7 VRMS at full rated 50 watts output power.
NFC-FFT Fire Fighter Telephone
The NFC-FFT has a telephone handset and user interface that allows an operator to communicate with remotely located telephone hand-sets in a building. It is housed in its own cabinet with key lock. It requires an external operator interface power connection (24 volts DC) from the NFC-50/100 main console or it may be powered from an external 24 VDC power supply such as HP300ULX. The NFC-FFT provides supervision, annunciation, and control for the local handset and for up to 24 remote telephone handsets. It provides indications of phone activation and corresponding trouble conditions. Refer to the NFC-FFT Fire Fighter Telephone manual. Not for use in UL2572 Mass Notification or Canadian applications.
NFC-50DA Distributed (Remote) Audio
The NFC-50DA is a 50-watt audio amplifier (audio booster) with its own cabinet and key lock. It requires an external data bus connec-tion and an external audio riser connection from the NFC-50/100 main console. The unit comes standard with 4 speaker circuits. An option card, NFC-CE4, provides 4 more speaker circuits for a total of 8. Speaker circuits are activated/de-activated manually or automat-ically by the NFC-50/100 main console. The unit is capable of either 25 VRMS or 70.7 VRMS operation. Refer to the NFC-50/125DA Dis-tributed Audio manual. Not for use in Canadian applications.
NFC-125DA Distributed (Remote) Audio
The NFC-125DA is a 125-watt audio amplifier (audio booster) with its own cabinet and key lock. It requires an external data bus con-nection and an external audio riser connection from the NFC-50/100 main console. The unit comes standard with four (4) speaker cir-cuits. An option card, NFC-CE4, provides 4 more speaker circuits for a total of eight (8). Speaker circuits are activated/de-activated manually or automatically by the NFC-50/100 main console. The unit is capable of 25 VRMS operation. Refer to the NFC-50/125DA Distributed Audio manual. Not for use in Canadian applications.
NFC-50/100DA Distributed (Remote) Audio
The NFC-50/100DA is a 50/100-watt audio amplifier (audio booster) with its own cabinet and key lock. It requires an external data bus connection and an external audio riser connection from the NFC-50/100 main console. The NFC-50/100DA is capable of producing up to 100 watts of audio power.