Appendix_6C_-_Basic_RP_LAN_room_layout.pdf

PDF 56 KB Posted

Attached to
Fully Integrated Records Facility (Offsite Document Control Center) Federal contract opportunity
Solicitation number
FDA-Off-Site-RIM-000141
Issued by
Department of Health and Human Services Food and Drug Administration

About this file

Appendice 6C

View the file

Other files for this federal contract opportunity

Other files attached to Fully Integrated Records Facility (Offsite Document Control Center), newest first.
File Type Posted
Amendment_7_to_Solicitation.pdf PDF
Revised_Attachment_3_-_Labor_Category_Descriptions.pdf PDF
Revised_Solicitation.pdf PDF
Amendment_6_to_Solicitation.pdf PDF
Revised_Solicitation.pdf PDF
IMG-20140612-00031.jpg JPG image
IMG-20140612-00030.jpg JPG image
Amendment_5_to_Solicitation.pdf PDF
IMG-20140612-00035.jpg JPG image
IMG-20140612-00036.jpg JPG image
Revised_Attachment_5_-_IDIQ_Pricing_Worksheet.xls XLS spreadsheet
IMG-20140612-00033.jpg JPG image
Revised_Appendix_3_-_Summary_of_Volume_of_Submissions_by_Center.pdf PDF
Amendment_4_to_Solicitation.pdf PDF
Revised_Attachment_3_-_Labor_Category_Descriptions.pdf PDF
Revised_Standard_Form_1449.pdf PDF
Revised_Solicitation.pdf PDF
Attachment_11_-_Form_3514.pdf PDF
Appendix_8_-_Estimate_of_Monthly_Scanning_Amounts.pdf PDF
Appendix_2A_-_Addendum_to_Physical_Security_Requirements_Specifications_For_FDA_Facilities.pdf PDF
Amendment_3_to_Solicitation.pdf PDF
Revised_Appendix_7_-_Glossary_of_Terms.pdf PDF
Revised_Appendix_3_-_Summary_of_Volume_of_Submissions_by_Center.pdf PDF
Revised_Attachment_1_-_IDIQ_Statement_of_Work.pdf PDF
Revised_Attachment_6_-_Task_Order_1_PricingWorksheet.xls XLS spreadsheet
Revised_Attachment_2_-_Task_Order_1_Performance_Work_Statement.pdf PDF
Revised_Attachment_5_-_IDIQ_Pricing_Worksheet.xls XLS spreadsheet
Amendment_2_to_Solicitation.pdf PDF
Site_Visit_Registrants.pdf PDF
Site_Visit_Attendees.pdf PDF
Site_Visit_Presentation.pdf PDF
Standard_Form_1449.pdf PDF
Solicitation.pdf PDF
Appendix_6A-_Small_Computer_Room_or_LAN_Closets_Electrical_Requirements.pdf PDF
Appendix_5_-_CDRH_Work_Functions.xls XLS spreadsheet
Attachment_5_-_IDIQ_Pricing_Worksheet.xls XLS spreadsheet
Attachment_10_-_Offeror_Represenatations_and_Certifications.doc DOC document
Attachment_9_-_Template_for_Questions.xls XLS spreadsheet
Attachment_7_-_Past_Performance_Questionnaire.doc DOC document
Appendix_2_-_FDA_Physical_Security_Requirements Specifications_for_FDA_Facilities.pdf PDF
Attachment_8_-_Form_3398.pdf PDF
Attachment_6_-_Task_Order_1_PricingWorksheet.xls XLS spreadsheet
Attachment_4_-_Wage_Determination.pdf PDF
Attachment_1_-_IDIQ_Statement_of_Work.pdf PDF
Appendix_1_-_FDA_IT_Facilities_Requirements.pdf PDF
Appendix_3_-_Summary_of_Volume_of_Submissions_by_Center.pdf PDF
Attachment_2_-_Task_Order_1_Statement_of_Work.pdf PDF
Attachment_3_-_Labor_Category_Descriptions.pdf PDF
Appendix_4_-_FDA_Document_Control_Facilities.xls XLS spreadsheet
Appendix_6B_-_Large_Computer_Room_General_Specifications_with__Electrical_Requirements.pdf PDF
Show all 50

Fully Integrated Records Facility (Offsite Document Control Center) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Patch Panel

Cisco 2851 Router

Cisco Switch

APC UPS Unit

Server

1. The size of the LAN closet shall be a minimum of 100 SF and used to house only IT, Network, LAN/VoIP and Security equipment.

1. The LAN closet shall be equipped with a lockable door, keyed independently from other office doors to limit access to unauthorized personnel.

Acceptable solutions are key lock, card reader of similar device that will restrict access to only those authorized to enter the LAN room.

1. The LAN closet shall have a light colored, non-conductive floor covering, such as linoleum or tiles. Carpet of any type will not be acceptable.

1. The entry door of the LAN closet shall swing outward to minimize the impact on the LAN closet’s interior space.

1. One or more, two post, floor mounted rack with cable and power management systems and ceiling ladders as necessary meet the entire floor data connection requirements , floor mounted with rear and side clearance to provide access and ventilation. Clearance is considered at least 36” to 45” from back of rack to the wall and 36” to 45” in front of rack

1. Provide one, 4'x4', 3/4" plywood de-mark panel, wall mounted, behind the rack. Dry wall compound skim coated and painted to match room color. Skin coating to be applied after code inspection to allow verification the plywood has the proper fire rating.

Provide, one 4X4, 120v / 20amp

(NEMA 5-20R)

dedicated quad box, mounted on the plywood panel to service wall mounted equipment.

Mount the quad box high on the plywood de-mark board, 2 to 3 foot below ceiling grid on the left side upper quadrant.

The plywood de-mark panel to support Telco gear and the FDA security system

Provide a #6 ground wire also known as a bus bar to be installed on the lower right corner of the plywood panel to service grounding requirements for wall mounted equipment

1. When Cisco 3750 switch(es) are planned (the number and type of switches to be determined by the VoIP Project Manager) for a given location, provide two, 120 volt / 20 amp (NEMA 5-20R) dedicated electrical circuit installed in the wall, directly behind the rack, at building standard height, below the plywood de-mark panel.

This will provide electric service for the Cisco 3750 switch(es), VoIP switch UPS unit and the SMS Server UPS unit.

Or When Cisco 4507 switch(es) are planned (the number and type of switches to be determined by the VoIP Project Manager) for a given location, provide two, 220 volt dedicated electrical circuits, one at 30 amps (NEMA L5-30R) and the second a 20 amps (NEMA L5-20R). Please install the receptacles, in the wall directly behind the rack, at building standard height and below the plywood de-mark panel. This will provide electric service for the VoIP Cisco 4507 switch(es), the VoIP switch UPS unit and the SMS Server UPS unit.

HVAC

Provide a separate, 24 hour, HVAC system adequate to provide proper ventilation for the installed of all VoIP, IT and Security equipment. Proper ventilation is considered to be temperature maintained between 68 and 72 degrees @ 50% RH. The system will require a minimum of both one air inlet and one outlet in the LAN area or the utilization of a ductless HVAC system.

Thermostat controlled exhaust fans are not to be considered a substitute for the supplemental cooling system

OOMB and SRST Analog lines

CONDUIT

Page-1�