Appendix_2A_-_Addendum_to_Physical_Security_Requirements_Specifications_For_FDA_Facilities.pdf

PDF 60 KB Posted

Attached to
Fully Integrated Records Facility (Offsite Document Control Center) Federal contract opportunity
Solicitation number
FDA-Off-Site-RIM-000141
Issued by
Department of Health and Human Services Food and Drug Administration

About this file

Appendix 2A - Addendum to Physical Security Requirements Specifications for FDA Facilities

View the file

Other files for this federal contract opportunity

Other files attached to Fully Integrated Records Facility (Offsite Document Control Center), newest first.
File Type Posted
Revised_Solicitation.pdf PDF
Amendment_7_to_Solicitation.pdf PDF
Revised_Attachment_3_-_Labor_Category_Descriptions.pdf PDF
Amendment_6_to_Solicitation.pdf PDF
Revised_Solicitation.pdf PDF
Revised_Attachment_5_-_IDIQ_Pricing_Worksheet.xls XLS spreadsheet
IMG-20140612-00033.jpg JPG image
IMG-20140612-00031.jpg JPG image
IMG-20140612-00030.jpg JPG image
Amendment_5_to_Solicitation.pdf PDF
IMG-20140612-00035.jpg JPG image
Appendix_8_-_Estimate_of_Monthly_Scanning_Amounts.pdf PDF
Revised_Appendix_3_-_Summary_of_Volume_of_Submissions_by_Center.pdf PDF
Amendment_4_to_Solicitation.pdf PDF
Revised_Attachment_3_-_Labor_Category_Descriptions.pdf PDF
Revised_Standard_Form_1449.pdf PDF
Revised_Solicitation.pdf PDF
Amendment_3_to_Solicitation.pdf PDF
Revised_Appendix_7_-_Glossary_of_Terms.pdf PDF
Revised_Appendix_3_-_Summary_of_Volume_of_Submissions_by_Center.pdf PDF
Revised_Attachment_5_-_IDIQ_Pricing_Worksheet.xls XLS spreadsheet
Revised_Attachment_1_-_IDIQ_Statement_of_Work.pdf PDF
Revised_Attachment_6_-_Task_Order_1_PricingWorksheet.xls XLS spreadsheet
Revised_Attachment_2_-_Task_Order_1_Performance_Work_Statement.pdf PDF
Amendment_2_to_Solicitation.pdf PDF
Amendment_1_to_Solicitation.pdf PDF
Site_Visit_Registrants.pdf PDF
Site_Visit_Attendees.pdf PDF
Site_Visit_Presentation.pdf PDF
Standard_Form_1449.pdf PDF
Solicitation.pdf PDF
Appendix_6A-_Small_Computer_Room_or_LAN_Closets_Electrical_Requirements.pdf PDF
Appendix_5_-_CDRH_Work_Functions.xls XLS spreadsheet
Appendix_3_-_Summary_of_Volume_of_Submissions_by_Center.pdf PDF
Appendix_6C_-_Basic_RP_LAN_room_layout.pdf PDF
Attachment_2_-_Task_Order_1_Statement_of_Work.pdf PDF
Attachment_3_-_Labor_Category_Descriptions.pdf PDF
Appendix_4_-_FDA_Document_Control_Facilities.xls XLS spreadsheet
Appendix_6B_-_Large_Computer_Room_General_Specifications_with__Electrical_Requirements.pdf PDF
Appendix_6D_-_Electrical_BTU_Loading_Worksheet_.xls XLS spreadsheet
Appendix_6E_-_ground-bus.pdf PDF
Appendix_7_-_Glossary_of_Terms.pdf PDF
Attachment_5_-_IDIQ_Pricing_Worksheet.xls XLS spreadsheet
Attachment_10_-_Offeror_Represenatations_and_Certifications.doc DOC document
Attachment_9_-_Template_for_Questions.xls XLS spreadsheet
Attachment_7_-_Past_Performance_Questionnaire.doc DOC document
Appendix_2_-_FDA_Physical_Security_Requirements Specifications_for_FDA_Facilities.pdf PDF
Attachment_8_-_Form_3398.pdf PDF
Attachment_6_-_Task_Order_1_PricingWorksheet.xls XLS spreadsheet
Attachment_4_-_Wage_Determination.pdf PDF
Show all 50

Fully Integrated Records Facility (Offsite Document Control Center) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Addendum to ID/IQ Appendix#2: Physical Security Requirements/Specifications for FDA Facilities

The following items contained in Section I. FDA Sole Occupant are not applicable:

1) Garage Area (Inside Parking);

2) Secured Area for Government Vehicles;

3) Perimeter Parking; and

4) Guard Service.

Intrusion Detection/Access Control System contained in Section II. FDA Occupant in Multi-Tenant Building is revised to state:

INTRUSION DETECTION/ACCESS CONTROL SYSTEM

1) Card readers will be utilized on all perimeter door entrances.

2) Intrusion alarms, door contacts, and window sensors will be utilized to protect all FDA space.

3) Video intercoms with remote release stations may be utilized.

4) Connected to FDA Physical Security Access Control System.

File details come from the government source that posted it. Updated .