FARM II Attachment L-6 Relevancy Matrix.xlsx
XLSX spreadsheet 40 KB Posted
- Attached to
- Facilities Acquisitions for Restoration and Modernization (FARM II) Federal contract opportunity
- Solicitation number
- FA9101-21-R-0001
About this file
This document includes a request for proposal for the Facilities Acquisitions for Restoration and Modernization II contract along with details about the related federal contract opportunity. The Air Force Materiel Command Test Center is soliciting proposals for an indefinite-delivery indefinite-quantity multiple award contract for mechanical, electrical, and instrumentation, data, and control systems design-build, construction, and two-phase design/build services at the Arnold Engineering Development Complex in Tennessee and its geographically separated units. The total estimated value of the contract(s) is $300 million over five years with a minimum guarantee of $1,000. The government intends to award a minimum of two and target of four contracts. Proposals are due by July 13, 2021. Work will primarily be performed at Arnold Air Force Base in Tennessee along with geographically separated units located in California, Maryland, Florida, New Mexico, and Ohio. Major work includes mechanical, electrical, instrumentation, data and control systems, and design/build projects to support research, development, test, and evaluation missions.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Prime
| Name of Prime Contractor | Reference 1 | Reference 2 | Reference 3 | Reference 4 | Reference 5 | ||
| Management Subfactor | |||||||
| M-2.2.1.1.1. | Teaming and Subcontractor Management | ||||||
| M-2.2.1.1.2. | Quality Management System | ||||||
| M-2.2.1.1.3. | Qualified Personnel | ||||||
| Technical Capabilities (SOW 1.2) | |||||||
| Mechanical | |||||||
| M1 | Air duct, expansion joints, and control/process valves (≥ 36” Ø and 150 psig) | ||||||
| M2 | High pressure duct/piping & valves (typ. 4" to 8"Ø, ≥ 4000 psig) | ||||||
| M3 | Large pressure vessels (≥ 2000 psig; ≥ 10K gallons) | ||||||
| M4 | Desiccant bed air dryers (≤ 300 psia & ≥ 200 lb/s) | ||||||
| M5 | Turning vanes for large air ducting (up to 50-ft Ø; 0.5-160 psia) | ||||||
| M6 | Cooling water/raw water pumps (300-50,000 gpm; 30-4,000 hp), filters/strainers, control/process valves,and distribution lines (typ. 6” to 90” Ø) | ||||||
| M7 | Hydraulic systems with high flow and pressure requirements (20-200 gpm (typ. 2 pumps @ 100 gpm ea) and 2500 psig) | ||||||
| M8 | Large steam distribution systems (60 kpph boilers, and piping up to 14" Ø) | ||||||
| M9 | Chillers and refrigeration equipment (300-5000 refrigeration tons) | ||||||
| M10 | Large heat exchangers: air to air; water to air; shell and tube, etc. (∆T up to 325 °F) | ||||||
| Electrical | |||||||
| E1 | Interior & exterior lighting for industrial buildings | ||||||
| E2 | Medium voltage gas insulated switchgear (≤ 13.8kV) | ||||||
| E3 | Unit substations (typical 6.9/2.4kV) | ||||||
| E4 | Motor Control Centers (≤ 600V) | ||||||
| E5 | Transformers (≤ 161/13.8kV) | ||||||
| E6 | Uninterruptable Power Supply (UPS) | ||||||
| E7 | Ducting/vaults/ cables (13.8kV & 6.9kV) | ||||||
| E8 | Motor exciters | ||||||
| E9 | Oil circuit breakers (typical 3000 amp & 550kV BIL) | ||||||
| E10 | Power panels/conduit/wiring (≤ 480V) | ||||||
| E11 | Variable frequency drives for motors (≥ 600V & ≤ 69kV) | ||||||
| ID&C | |||||||
| I1 | PLC-based industrial control systems | ||||||
| I2 | High Speed (< 10ms Loop Time) facility control systems | ||||||
| I3 | Controls software development and modification | ||||||
| I4 | Secure control systems | ||||||
| I5 | Data logging system design and integration | ||||||
| I6 | Control systems instrumentation design and integration |
&"Times New Roman,Bold"ATTACHMENT L-6 RELEVANCY MATRIX &"Times New Roman,Regular"FARM II
FA9101-21-R-0001
Attachment 8
Partners
| Name of Partner (Subcontractor/Joint Venture) | Reference 1 | Reference 2 | Reference 3 | ||
| Management Subfactor | |||||
| M-2.2.1.1.1. | Teaming and Subcontractor Management | ||||
| M-2.2.1.1.2. | Quality Management System | ||||
| M-2.2.1.1.3. | Qualified Personnel | ||||
| Technical Capabilities (SOW 1.2) | |||||
| Mechanical | |||||
| M1 | Air duct, expansion joints, and control/process valves (≥ 36” Ø and 150 psig) | ||||
| M2 | High pressure duct/piping & valves (typ. 4" to 8"Ø, ≥ 4000 psig) | ||||
| M3 | Large pressure vessels (≥ 2000 psig; ≥ 10K gallons) | ||||
| M4 | Desiccant bed air dryers (≤ 300 psia & ≥ 200 lb/s) | ||||
| M5 | Turning vanes for large air ducting (up to 50-ft Ø; 0.5-160 psia) | ||||
| M6 | Cooling water/raw water pumps (300-50,000 gpm; 30-4,000 hp), filters/strainers, control/process valves,and distribution lines (typ. 6” to 90” Ø) | ||||
| M7 | Hydraulic systems with high flow and pressure requirements (20-200 gpm (typ. 2 pumps @ 100 gpm ea) and 2500 psig) | ||||
| M8 | Large steam distribution systems (60 kpph boilers, and piping up to 14" Ø) | ||||
| M9 | Chillers and refrigeration equipment (300-5000 refrigeration tons) | ||||
| M10 | Large heat exchangers: air to air; water to air; shell and tube, etc. (∆T up to 325 °F) | ||||
| Electrical | |||||
| E1 | Interior & exterior lighting for industrial buildings | ||||
| E2 | Medium voltage gas insulated switchgear (≤ 13.8kV) | ||||
| E3 | Unit substations (typical 6.9/2.4kV) | ||||
| E4 | Motor Control Centers (≤ 600V) | ||||
| E5 | Transformers (≤ 161/13.8kV) | ||||
| E6 | Uninterruptable Power Supply (UPS) | ||||
| E7 | Ducting/vaults/ cables (13.8kV & 6.9kV) | ||||
| E8 | Motor exciters | ||||
| E9 | Oil circuit breakers (typical 3000 amp & 550kV BIL) | ||||
| E10 | Power panels/conduit/wiring (≤ 480V) | ||||
| E11 | Variable frequency drives for motors (≥ 600V & ≤ 69kV) | ||||
| ID&C | |||||
| I1 | PLC-based industrial control systems | ||||
| I2 | High Speed (< 10ms Loop Time) facility control systems | ||||
| I3 | Controls software development and modification | ||||
| I4 | Secure control systems | ||||
| I5 | Data logging system design and integration | ||||
| I6 | Control systems instrumentation design and integration |
&"Times New Roman,Bold"ATTACHMENT L-6 RELEVANCY MATRIX &"Times New Roman,Regular"FARM II
FA9101-21-R-0001
Attachment 8
File details come from the government source that posted it. Updated .