01f. Attachment F - Fire Alarm and Fire Suppression System.pdf
PDF 262 KB Posted
- Attached to
- MHMV230034 Federal contract opportunity
- Solicitation number
- FA940124B0004
About this file
The provided file is Attachment F - Fire Alarm and Fire Suppression System for the federal contract opportunity to renovate Building 20202 East Wing at Kirtland Air Force Base in New Mexico. The attachment includes a detailed floor plan of the building, highlighting the location of various fire alarm and suppression system components, such as pull stations, smoke detectors, sprinkler heads, and the fire alarm control panel. The contract opportunity, identified as Solicitation Number FA940124B0004, is for the renovation of approximately 5,500 square feet of the second floor of the East Wing, involving abatement, demolition, new wall construction, flooring, communication upgrades, painting, and installation of new security doors. The contracting agency is the Department of the Air Force Materiel Command Nuclear Weapons Center.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U
U
T
T
S
S
R
R
Q
Q
P
P
O
O
N
N
MK
3"Ø
3"Ø
3"Ø
3"Ø
3"Ø3"Ø
1"Ø1 1/4"Ø1 1/2"Ø1 1/2"Ø
1 1/4"Ø 1"Ø
4"Ø
4"Ø
1"Ø
1"Ø
1 1/2"Ø1 1/4"Ø1"Ø 1 1/2"Ø 1 1/4"Ø
1"Ø
1"Ø
1 1/2"Ø1 1/4"Ø 1"Ø
90° REDUCING ELBOW
PIPING TO CONTINUE
1"Ø 1 1/4"Ø
1 1/4"Ø 1"Ø
SFS
Reports
Analysis
SFG-Battle Staff Conf Rm
Interview
Room
SFS/S2R
Records Storage and Clearing
Barrel
SFS/CSS
SFS/CSS
SFS/SEL
SFS/S2
Office
Waiting
Area
Evidence Rm
Conference
Conference
FOUND
PROPERTY
ROOM
VIEWING RM
/EQUIPMENT
STORAGE
SF CC
HALLWAY
H A
L L
W A
Y
P-2
P-1
HALLWAY
F
F
COMM/
SERVER
RM
MENS RR
WOMENS RR
Interview
Room
F
S
D
H
D
FACP
FIRE ALARM LEGEND:
PULL STATION
STROBE
HORN STROBE
HORN
SMOKE DETECTOR
HEAT DETECTOR
FIRE ALARM CONTROL PANEL
WALL MOUNT EXIT SIGN
CEILING MOUNT EXIT SIGN
FIRE EXTINGUISHER
F A
C P
GENERAL NOTE
ALL DEVICES AND PIPING ARE TO BE FIELD
VERIFIED BY CONTRACTOR.
FIRE SUPPRESSION SYSTEM
155°F SIDEWALL SPRINKLER HEAD
155°F PENDENT SPRINKLER RECESSED TYPE
LIMITS OF CONSTRUCTION
1" = 1'-0"
KIRTLAND AFB
Building - 20202 - 1ST FLOOR - LOBBY
Building - 20202 - 2ND FLOOR, EAST WING - ATTACHMENT F - FIRE ALARM & FIRE SUPPRESSION SYSTEM