01b. Attachment B - B20202 2nd Floor East Wing Conceptual Plan.pdf
PDF 257 KB Posted
- Attached to
- MHMV230034 Federal contract opportunity
- Solicitation number
- FA940124B0004
About this file
This document is a conceptual floor plan for the renovation of the 2nd floor East Wing of Building 20202 at Kirtland Air Force Base in New Mexico. The project, solicited under Solicitation Number FA940124B0004, will renovate approximately 5,500 square feet of interior space, including abatement and removal of existing flooring, demolition of selected walls, installation of new walls to create new office, meeting, interview, and storage spaces, new carpeting, updated communication wiring, painting, and installation of new security doors. The renovations will be performed for the Department of the Air Force Materiel Command Nuclear Weapons Center. The document provides a detailed layout of the proposed renovations, including the locations of new walls, doors, audio/visual equipment, and security features.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U
U
T
T
S
S
R
R
Q
Q
P
P
O
O
N
N
MK
SFS
Reports
Analysis
SFG-Battle Staff Conf Rm
Interview
Room
SFS/S2R
Records Storage and Clearing
Barrel
SFS/CSS
SFS/CSS
SFS/SEL
SFS/S2
Office
Waiting
Area
Evidence Rm
Conference
Conference
FOUND
PROPERTY
ROOM
VIEWING RM
/EQUIPMENT
STORAGE
SF CC
HALLWAY
H A
L L
W A
Y
P-2
P-1
HALLWAY
COMM/
SERVER
RM
MENS RR
WOMENS RR
Interview
Room
7 7
1414 13
PROPOSED/NEW WALLS
INTERIOR WALLS FROM
FLOOR TO LAY-IN CEILING
SOUND RATED WALLS
FULL HEIGHT SECURITY WALL FROM
FLOOR TO DECK ABOVE
EXISTING WALLS TO REMAIN
SOUND INSULATED WALLS PER S.O.W.
KEY NOTES:
SOUND RATED WALLS TO BOTTOM OF DECK
WALLS FROM FLOOR TO LAY-IN CEILING
WALL AND DOOR TO BE REMOVED
EXISTING WALLS HAS FRAMING EXTENDED TO
BOTTOM OF DECK. MODIFY TO BE SOUND
RATED
NEW DOOR WITH CIPHER LOCK ROUGH IN
CIPHER LOCKED DOOR TO REMAIN
NEW KEYED LOCKED DOOR
NEW DOOR TO MEET STC RATING OF 45 WITH
CIPHER LOCK ROUGH IN
DEMO PA SYSTEM IN CEILING AND REPLACE
WITH NEW 24"x24"CEILING TILE
WINDOW SECURITY BARS
SECURITY WALLS FROM FLOOR TO DECK
ABOVE
EXISTING HEAT PUMP (HP-3) TO REMAIN
AUDIO/VIDEO FEED
VIDEO CAMERA ROUGH IN
SOUND INSULATED WALLS PER S.O.W.
DATA-COMMS SYSTEM LEGEND:
PROPOSED DATA - COMMS
CONNECTION LOCATION
TV / MONITOR
LIMITS OF CONSTRUCTION
1" = 1'-0"
KIRTLAND AFB
Building - 20202 - 2ND FLOOR, EAST WING - ATTACHMENT B - CONCEPTUAL PLAN
| Sheets and Views |
| Bldg - 20202-2 - EAST WING - ATTACHMENT B - CONCEPTUAL PLAN |