ZHTV130068_Combined_Drawings_with_Option.pdf
PDF 5 MB Posted
- Solicitation number
- FA8601-18-R-0018
About this file
Project Drawings
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STUCCOSTUC
WOOD
WITH
WEST
WELDED WIRE FABRIC
WOOD PANELING
WATERPROOF
WATER-RESISTANT
WIDE FLANGE
WATER CLOSET
WDP
WRES
WWF
WP
W
WC
WF
WD
W/
W
TREADS
URINAL
THROUGH
TYPICAL
TERRAZZO
TONGUE AND GROOVE
TOP OF STEEL
TOP OF WALL
TOP OF MASONRY
TELEPHONE
TOP OF CONCRETE
STRUCTURAL
TOP AND BOTTOM
SHEET VINYL
SUSPENDED
VERTICAL
VINYL TILE
VINYL WALL COVERING
VINYL COMPOSITION TILE
VINYL (BY OWNER)
VITRIFIED CLAY PIPE
THRU
V
VERT
VWC
VCP
VCT
VO
VT
TYP
UR
U
T & B
TEL
T & G
TOS
TOW
TOC
TOM
TER
T
STRUCT
SUSP
SV
T
RISERS
RADIUS
QUARRY TILE
ROOM
RESILIENT
RESISTANT
REQUIRED
RETAINING
RECESSED
SECTION
SQUARE
STEEL
STANDARD
SHEET
SIMILAR
SEALER
SOUTH
SCHEDULE
STAINLESS STEEL
SPECIFICATION
SOLID CORE WOOD
ROUGH OPENING
REINFORCED
REFERENCE
ROOF DRAIN
RUBBER
RM
SECT
SST
STL
STD
SHT
SIM
SPEC
SLNT
SQ
SCW
SCHED
S
RO
S
RBR
REINF
RES
RESIL
REQD
RET
REC
REF
RD
R R
QT
R
Q
PORCELAIN
PLATE
PLYWOOD
PLASTER
PAINT
PARTITION
POLYVINYL CHLORIDE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PLASTIC LAMINATE
PORC
PSF
PLAS
PLYWD
PVC
PTN
PSI
PT
PLAM
PL
P
TROWELED EPOXYTE
RUBBER PADSRP
CONSTR CONSTRUCTION
EAST
ENAMEL
EXPANSION JOINT
EACH
ELEVATION
ELECTRICAL
EXPOSED STRUCTURE
EXISTING
EXPANSION
EXTERIOR
EQUAL
EQUIPMENT
EACH WAY
ELECTRIC WATER COOLER
EPOXY PAINTEPT
EWC
EXIST
EXP
EXT
EXP
EQUIP
EQ
EW
ENAM
ELEC
EJ
EL
E
EA
E
DIMENSION
DISPENSER
COLD ROLLED
DETAIL
DIAGONAL
DIAMETER
DOUBLE
CERAMIC TILE
CONTINUOUS
CARPET
DRYWALL
DRAWING
DOOR
DOWNSPOUT
DOWN
DIA
DISP
DIAG
DWG
DN
DW
DR
DS
DIM
DET
DBL
CPT
CONT
CR
CT
D
ACOUSTICAL TILE CEILINGACT
BRICKBRK
BASEMENT
CERAMIC
COLUMN
CONCRETE
CLEAN OUT
CEILING
CERAMIC MOSAIC
CORNER GUARD
CONTROL JOINT
CEMENT PLASTER
CEMENT
CATCH BASIN
CABINET
CONCRETE MASONRY UNIT
CER
CO
CONC
COL
CM
CLG
CMU
CG
CJ
BSMT
CEM PLAS
CAB
CEM
CB
C
ATTENUATION
ANCHOR
ALUMINUM
ALTERNATE
APPROXIMATELY
ADJUSTABLE
ABOVE FINISHED GRADE
ABOVE FINISHED FLOOR
BEARING
BOARD
BUILDING
BEAM
BLOCK
BOTTOM
BRG
BOT
BLK
BLDG
BM
BD
B
ATTEN
AFG
ALUM
AHR
APPROX
AFF
ADJ
ALT
SYMBOLS
CHANNEL
DIAMETER
ANGLE
AND
CENTER LINE
ACOUSTICAL
ACOUS. PLASTER
ACOUS
ACPL
LC
A
AT
BOLLARDBLD
FOUNDATION
FLOOR DRAIN
FLAT HEAD
FIREPLACE
FRAME
FIRE TREATED
FIREPROOFING
FOOTING
FINISH
FLOOR
FLUORESCENT
FLASH COVE
FPL
F.PRG
FTG
FR
FT
FDTN
FLUOR
FLCV
FH
FLR
FIN
FD
F
GEN
GALV
GYP
GYP BD
GYP PLAS
GL BLK
HDWD
HNDRL
HORIZ
HDW
INSUL
INV
IN
ID
INT
HM
HT
HD
HC
GA
GI
GT
GT
GL
GFI
GC
G
GYPSUM
INVERT
INSULATION
INCH
INTERIOR
INSIDE DIAMETER
I
H
HARDWOOD
HANDRAIL
HEIGHT
HOLLOW METAL
HORIZONTAL
HARDWARE
HEAD
HOLLOW CORE
GYPSUM BOARD
GYPSUM PLASTER
GROUND FAULT INTERRUPT
GENERAL CONTRACTOR
GAUGE
GLAZED TILE
GROUT
GENERAL
GLASS
GLASS BLOCK
GALVANIZED IRON
GALVANIZED
GROUND
G
JAN
J-BOX
JT
JANITOR
JOINT
JUNCTION BOX
J
KPL
KIT
KICKPLATE
KITCHEN
K
LAV
LAM
LVR
LT WT
LINO
LOUVER
LAVATORY
LAMINATE
LINOLEUM
LIGHT WEIGHT
L
MECH
MACH
MAX
MULL
MTL
MFR
MIN
MO
MR
MH
MANUFACTURER
MULLION
METAL
MASONRY OPENING
MARBLE
MINIMUM
MAN HOLE
MECHANICAL
MACHINE
MAXIMUM
M
NTS
NOM
N
NIC
N
NOT TO SCALE
NORTH
NOMINAL
NOT IN CONTRACT
OPP
OPNG
OC
OH
OD
OPPOSITE
ON CENTER
OVERHEAD
OPENING
OUTSIDE DIAMETER
O
HB HOSE BIB
ENLARGED DETAIL
INTERIOR ELEVATIONS
EXTERIOR ELEVATIONS
BUILDING / DETAIL SECTION
DRAWING TITLE
END OF SECTION
DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER
DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER
SCALE OF DRAWING
DRAWING TITLE
DRAWING REFERENCE NUMBER
DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER /
DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER
A.401
A.401
A.401
DRAWING NAME
1/4" = 1'-0"
A.701
A.401
BUILDING
SECTION
WALL
SECTION
ELEVATION INDICATIONS
GLASS
ACOUSTICAL
TILE
GYPSUM
BOARD
CONCRETE SIDING
LATH AND
PLASTER
MASONRY
WOOD
FINISHES
INSULATION
LOOSE OR
BATT
GLASS
SMALL SCALE
PLYWOOD
FINISH
RIGID
LARGE SCALE
ROUGH
METAL
METAL @
LARGE SCALE
STONE
CAST STONE
C.M.U.
METAL @
SMALL SCALE
FACE BRICK
CONCRETE
CONCRETE
EARTHWORK
EARTH OR
COMPACT FILL
LT. WEIGHT
CONCRETE
GRANULAR
FILL
SPRAY FOAM
GLASS BLOCK
BLOCKING
MORTAR
ROCK
BRICK CMU SHINGLES
CARPET
SHADED PORTION IS
THE SIDE CONSIDERED
ROOM NAME
KEY NOTE
REVISION/CHANGE
ROOM NUMBER DATUM POINT
MATCH LINE
OPENING SYMBOL
DOOR SYMBOL
GRAPHIC SYMBOLS
WORK POINT
COLUMN CENTER LINES
ROOM SYMBOL
WALL TYPE
R.D.
MISCELLANEOUS SYMBOLS
F.D.
CHANGE IN ELEVATION
ROOF DRAIN
FLOOR DRAINA
STORAGE
POCKET DOOR
BI-FOLD DOOR
DOUBLE ACTING DOOR
EXIST. DOOR TO REMAIN
NEW SINGLE DOOR
TYPICAL DOOR CONVENTIONS
ACCORDIAN FOLDING DOOR
DOOR WITH 180 DEGREE SWING
DOOR WITH EMERGENCY RELEASE HARDWARE
EXIST. DOOR TO BE REMOVED
NEW PAIR OF DOORS
4454 Idea Center Blvd Dayton, OH 45430-1500 937.461.5660 Fax: 937.461.0743
Proj. No.:
Date:
Revisions:
Sheet Name:
R E
P A
IR
H
A N
G A
R
H A
N G
A R
W
IN
D O
W S
P R
O
JE
C T:
Z H
TV
FA
C
IL
IT
Y : 3
W
PA
FB
3/
/2
4:
:0
PM
076800 04-11-2017
ABBREVIATIONS &
SYMBOLS
A-001
100% SUBMITTAL
ABBREVIATIONS REFERENCE SYMBOLS MATERIAL SYMBOLS
DRAWING SYMBOLS DOOR CONVENTIONS
Jill Elder - Liscence #6608
CL
A B E H L P
0"
0"
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
4'
0"
3'
8"
1' - 3" 8' - 7" 50' - 0" 50' - 0" 50' - 0" 50' - 0" 1' - 3"
A-2011Si m
A-201 4 Si m
A-202
Sim
A-202
Sim
200' - 0"
A-202
Sim
A-201 2 A-2013Si m
A-202
Sim
EXISTING SIDE WINDOWS METAL PANELLED OVER TO REMAIN
C
LE
R
ES
TO
R
Y
- O
PE
R
AB
LE
W
IT
H V
EN
TS
M
ET
AL
P
AN
EL
O
VE
R
W
IN
D O
W S
C
LE
R
ES
TO
R
Y
- O
PE
R
AB
LE
N O
V
EN
TS
M
ET
AL
P
AN
EL
O
VE
R W
IN
D
O W
S
NOTE: REFER TO G-101 FOR FULL PROJECT DESCRIPTION. ALSO SEE
DESCRIPTION ABOVE TITLE OF EACH INDIVIDUAL ELEVATION TO AID IN THE
BIDDING PROCESS.
HANGAR #2
PHASE #1
HANGAR #1
PHASE #2
FRONT ENTRY SIDEHANGAR DOORS SIDE
SK
EE
L A
VE
N
U E
R U
N W
A Y
SI
D
E
EXISTING SIDE WINDOWS METAL PANELLED OVER TO REMAIN
INT. CLERESTORY
CATWALKS. CONT. INT. FIRE-
RATED PLYWOOD TO BE
INSTALLED ON THE FLOOR
AND 48" UP ON CATWALK
RAILING w/ CONT. SILICONE
SEALANT AND CAULK SUCH
THAT CATWALK BECOME
IMPENETRABLE SELF
CONTAINED SPACE TO
CAPTURE ANY FOD - 264 LF X
4' FLOOR X 4' HIGH RAILING =
2,112 SF X 6 CATWALKS =
12,672 SF FIRE-RATED
PLYWOOD TOTAL w/ CONT.
SEALANT
4' - 0" TYP. CATWALKS
INT. CLERESTORY CATWALKS.
CONT. INT. FIRE-RATED
PLYWOOD TO BE INSTALLED
ON THE FLOOR AND 48" UP ON
CATWALK RAILING w/ CONT.
SILICONE SEALANT AND
CAULK SUCH THAT CATWALK
BECOME IMPENETRABLE
SELF CONTAINED SPACE TO
CAPTURE ANY FOD - 264 LF X
4' FLOOR X 4' HIGH RAILING =
2,112 SF X 6 CATWALKS =
12,672 SF FIRE-RATED
PLYWOOD TOTAL w/ CONT.
SEALANT
C
LE
R
ES
TO
R
Y
- O
PE
R
AB
LE
W
IT
H V
EN
TS
M
ET
AL
P
AN
EL
O
VE
R
W
IN
D O
W S
C
LE
R
ES
TO
R
Y
- O
PE
R
AB
LE
N O
V
EN
TS
M
ET
AL
P
AN
EL
O
VE
R W
IN
D
O W
S
METAL PANEL OVER EXISTING SIDE WINDOWS
METAL PANEL OVER EXISTING SIDE WINDOWS
R
ES
TO
R
E
AL
L
EX
IS
TI
N G
W
IN
D O
W S
IN
C
LU
D
IN
G
C
LE
R
ES
TO
R
Y
PE
R T
H
IS
E
LE
VA
TI
O N
R
ES
TO
R
E
AL
L
EX
IS
TI
N G
C
LE
R
ES
TO
R
Y W
IN
D
O W
S
AB
O
VE
D O
O R
S
PE
R T
H
IS
E
LE
VA
TI
O N
1/A-201
2/A-201
2/A-202
1/A-202
3/A-2024/A-202
3/A -2
4/A -2
HANGAR DOOR SIDE 2/A-201
ENTRANCE SIDE 1/A-201
CL
B P
4'
0"
3'
8"
200' - 0"
NOTE: REFER TO G-101 FOR PROJECT
DESCRIPTION AND PHASING. ALSO SEE
DESCRIPTION ABOVE TITLE OF EACH INDIVIDUAL
ELEVATION TO AID IN THE BIDDING PROCESS.
HANGAR #2
PHASE #1
HANGAR #1
PHASE #2
FRONT ENTRY SIDE
HANGAR DOORS SIDE
SK
EE
L A
VE
N
U E
R U
N W
A Y
SI
D
E
15' - 0"
15' - 0"
ALL EXISTING LOOSE FOD, BIRD DROPPINGS, DUST,
LEAD BASED PAINT, & ASBESTOS RESTING ON ALL
INT. PERIMETER WALLS, INT. CLERESTORY WALLS,
CATWALKS, AND ADJACENT STRUCTURE, PIPING,
HVAC, AND ALL OTHER ELEMENTS WITHIN A 15'
RADIUS OF THESE WALLS TO BE DRY CLEANED /
DECONTAMINATED w/ HEPA VACUUMS AS WELL AS
ANY DEBREE CREATED DURING CONSTRUCTION. TO
INCLUDE HANGAR DOOR INTERIORS. TO INCLUDE
TOPS OF ALL HORIZONTAL SURFACES. TO INCLUDE
DISPOSAL. FOR OPTIMAL PERFORMANCE UTILIZE
EACH ENTIRE INDIVIDUAL HANGAR AS A SINGLE SELF
CONTAINED CONTAINMENT ZONE DURING CLEANING /
DECONTAMINATION PROCEDURE. ENTIRE HANGAR TO
BE CLEANED / DECONTAMINED UPON COMPLETION.
FOR OPTIMAL PERFORMANCE UTILIZE ENTIRE
INDIVIDUAL HANGAR AS A SINGLE CONTAINMENT
ZONE DURING CLEANING / DECONTAMINATION
PROCEDURE. TEMPORARY BARRICADES DURING
WINDOW RESTORATION TO BE SEALED TO EXISTING
BUILDING AS REQUIRED BY BASE REGULATIONS TO
MAINTAIN SELF-CONTAINED INTERIOR HAZARDOUS
CONTAINMENT ZONE, AND PROTECT THE INTERIOR
OF THE BUILDING FROM THE ELEMENTS.
928 (264 LF X 2 + 200 LF X 2) LF PERIMETER WALLS X 54' H =
APPROX. 50,112 SF.
+ 628 LF (264 LF X 2 + 50 LF X 2)X 2 CLERESTORY BUMP
OUTS X 17' H = APPROX. 21,352 SF
71,464 SF INT. VERTICAL SURFACES / HANGAR
X 2 HANGARS
= 142,928 SF VERT SURFACES TOTAL
SUBTRACT 21,812 RESTORED WINDOW SF
121,116 SF TOTAL WALL CLEAN-UP / DECONTAMINATION
PER ENTIRE PROJECT + 5,000 SF MISC. CLEAN-UP
NOTE: REFER TO PHASING & GENERAL NOTES ON
G-101. REFER TO SPECIFICATIONS SECTION 02
EXISTING CONDITIONS AND SECTION 4 OF
EXISTING ENVIRONMENTAL ANALYSIS REPORT
FOR ALL REQUIREMENTS AND REGULATIONS.
COORDINATE w/ BASE.
4454 Idea Center Blvd Dayton, OH 45430-1500 937.461.5660 Fax: 937.461.0743
Proj. No.:
Date:
Revisions:
Sheet Name:
R E
P A
IR
H
A N
G A
R
H A
N G
A R
W
IN
D O
W S
P R
O
JE
C T:
Z H
TV
FA
C
IL
IT
Y : 3
W
PA
FB
3/
/2
4:
:1
PM
076800 04-11-2017
FLOOR PLAN
A-101
100% SUBMITTAL
SCALE : 1" = 40'-0"1 FLOOR PLAN
N
SCALE : 1" = 80'-0"2 SITE PLAN
SCALE : 1" = 30'-0"3 ORIGINAL CONSTRUCTION AERIAL
FOR REFERENCE ONLY
FOR REFERENCE ONLY
SCALE : 1" = 80'-0"4 CLEANING CONTAINMENT PLAN
Jill Elder - Liscence #6608
TOTAL # OF
WINDOW TYPE
EXISTING WINDOW TYPE & COUNT
WINDOW
TYPE
W1
W1a
W2
W3
W3a
W3b
W4
W5
W6
W7
W8
W9
W10
W11
W12
W2n
W3n
1084TOTAL # OF
WINDOWS PER
EXISTING
BUILDING
EQ
EQ
EQ
EQ
EQ
W1
8'
3/
8"
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
4' - 10"
EQ
EQ
EQ
EQ
6'
/8
4' - 10"
W2
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
EQ
EQ
EQ
EQ
EQ
EQ
4' - 10"
/8
W3W1a
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
1 1/4"
1/
4" CONT. 1" TO 1-3/8" STEEL
FRAME AROUND ENTIRE
WINDOW - FIELD VERIFY
WIDTH OF EXISTING
FRAME. TYPICAL TO ALL
WINDOW FRAMES.
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
4' - 10"
EQ
EQ
EQ
EQ
6'
/8
W3a W3b
EQ
EQ
EQ
EQ
EQ
EQ
/8
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
4' - 10"
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
4' - 10"
EQ
EQ
EQ
EQ
EQ
EQ
/8
EQ
EQ
EQ
EQ
EQ
8'
3/
8"
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
4' - 10"
W2N IDENTICAL SIZE TO W2 BUT IS A NEW
WINDOW THAT HAS BEEN REPLACED.
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
EQ
EQ
EQ
EQ
EQ
EQ
4' - 10"
/8
W3N
IDENTICAL SIZE TO W3 BUT IS A NEW
WINDOW THAT HAS BEEN REPLACED.
REPLACEMENT WINDOW TO BE
CUSTOM FABRICATED TO EXACTLY
MATCH ORIGINAL CONSTRUCTION.
1' - 4 1/2" 1' - 4 1/2" 1' - 4 1/2" 1' - 4 1/2"
1' - 4 1/2"
6' - 10 1/2"
W8
EQ
EQ
EQ
EQ
EQ
8'
3/
8"
1' - 2 1/2" 1' - 2 1/2"
2' - 5"
EQ
EQ
EQ
EQ
6'
/8
W9
1' - 2 1/2" 1' - 2 1/2"
2' - 5"
/8
W10
EQ
EQ
EQ
EQ
EQ
EQ
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
3' - 7 1/2"
EQ
EQ
EQ
5'
3/
4"
W11
6'
6"
W12
2' - 2 1/2"
EQEQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
1' - 5"
6'
/8
8 1/2" 8 1/2"
EQ
EQ
EQ
EQ
EQ
1' - 5" 8'
3/ 8"
8 1/2" 8 1/2"
EQ
EQ
EQ
EQ
EQ
EQ
/8
1' - 5"
W4 W5 W6
EQ
EQ
EQ
EQ
1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2" 1' - 2 1/2"
1' - 2 1/2"
6' - 0 1/2"
6'
/8
W7
TYPE NOT INCLUDED IN RESTORATION
TO BE METAL PANELLED OVER
A-602
Sim
A-602
Sim
A-602
Sim 2
A-602
Sim
A-602
Sim
A-602
Sim
A-602
Sim
A-602
Sim
HEAD DTL. 3/A-602
TYP. ALL WINDOWS
JAMB DTL. 1/A-602
TYP. ALL WINDOWS
SILL DTL. 4/A-602 TYP.
ALL WINDOWS U.N.O.
SILL DTL. 2/A-602 TYP.
ALL FIRST FLOOR
WINDOWS (ALL NOTED)
TYPE NOT INCLUDED IN
RESTORATION TO BE METAL
PANELLED OVER
TYPE NOT INCLUDED IN
RESTORATION TO BE METAL
PANELLED OVER
= OPERABLE WINDOWS (SEE ELEVS.)
= HVAC INFILL (SEE ELEVS)
= EXISTING METAL PANEL OVER EXISTING WINDOWS (SEE ELEVS)
4454 Idea Center Blvd Dayton, OH 45430-1500 937.461.5660 Fax: 937.461.0743
Proj. No.:
Date:
Revisions:
Sheet Name:
R E
P A
IR
H
A N
G A
R
H A
N G
A R
W
IN
D O
W S
P R
O
JE
C T:
Z H
TV
FA
C
IL
IT
Y : 3
W
PA
FB
3/
/2
4:
:0
PM
076800 04-11-2017
WINDOW SCHEDULE
A-601
100% SUBMITTAL
SCALE : 1/4" = 1'-0"1 WINDOW SCHEDULE
NOTE: SCHEDULE DEPICTS WINDOW TYPES FOR ENTIRE BUILDING. SOME TYPES WILL NOT BE APPLICABLE TO THE RESTORATION PROCESS AS THEY WILL BE METAL PANELLED OVER. REFER TO ELEVATIONS IN CONJUNCTION WITH WINDOW SCHEDULE TO NOTE THE TYPES OF WINDOWS THAT WILL BE RESTORED.
CONTRACTOR TO VERIFY EXISTING WINDOW COUNT AS WELL AS COUNT OF HOW MANY WILL BE RESTORED.
NOTE: SCHEDULE DEPICTS WINDOW TYPES FOR ENTIRE BUILDING. SOME TYPES WILL NOT BE APPLICABLE TO THE RESTORATION PROCESS AS THEY WILL BE METAL PANELLED OVER. REFER TO ELEVATIONS IN CONJUNCTION WITH WINDOW SCHEDULE TO NOTE THE TYPES OF WINDOWS THAT WILL BE RESTORED. CONTRACTOR TO VERIFY EXISTING WINDOW COUNT AS WELL AS COUNT OF HOW MANY WILL BE RESTORED.
Jill Elder - Liscence #6608
SCALE : 1/4" = 1'-0"
WINDOW TYPE KEY
CL
A B E H L P
5 5
5 5
4454 Idea Center Blvd Dayton, OH 45430-1500 937.461.5660 Fax: 937.461.0743
Proj. No.:
Date:
Revisions:
Sheet Name:
R E
P A
IR
H
A N
G A
R
H A
N G
A R
W
IN
D O
W S
P R
O J E
C T
Z
H T
V
F
A C
IL
IT
Y
W P
A F
B
/3
/2
:4 :0
P
M
076800
04-11-2017
MECHANICAL &
ELECTRICAL FLOOR
PLAN
ME101
100% SUBMITTAL
SCALE : 1" = 40'-0"1
MECHANICAL/ELECTRICAL FLOOR PLAN
N
DRAWING NOTES
1. THE EXISTING TOILET ROOM EXHAUST DUCT CURRENTLY LOCATED IN THE SOUTHEAST
CORNER OF THE HANGAR #2 TO BE RELOCATED TO DISCHARGE THROUGH THE METAL
WALL PANEL IN LIEU THROUGH THE GLAZING OF THE WINDOW SYSTEM. NEW LOUVERS TO
BE INSTALLED FOR THE NORTH AND SOUTH TOILET ROOMS. FIELD VERIFY EXACT LOUVER
SIZE AND EXISTING CLEARANCES FOR NEW DUCTWORK.
2. THE EXISTING STORM WATER PIPE IN THE NORTHEAST WALL OF THE HANGAR #2 TO BE
RELOCATED TO PENETRATE THE MASONRY WALL BELOW THE WINDOWS. COORDINATE
EXACT LOCATION WITH E.C.
3. THE EXISTING COMPRESSED AIR PIPING LOCATED IN THE NORTHEAST WALL OF THE
HANGAR #2 TO BE RELOCATED TO PENETRATE THE MASONRY WALL BELOW THE WINDOWS.
4. EXISTING LOUVERS AT CLERESTORY LEVEL ON THE EAST SIDE TO BE REMOVED AND
REPLACED WITH THE NEW LOUVERS. FIELD VERIFY EXACT LOUVER SIZE.
5. EXISTING MANUAL OPERATING SYSTEM FOR THE CLERESTORY WINDOWS TO BE REPLACED.
PROVIDE NEW GEARS AND CHAIN OPERATORS TO RESTORE MANUAL OPERATING SYSTEM
TO ORIGINAL CONDITIONS. (8) - WINDOW OPERATOR IN EACH HANGAR (#2 AND #1) TO BE
REPLACED. WEST SIDE OF HANGARS, THE OPERATOR SHALL HAVE EXTENSIONS ON THE
GEAR SHAFT FOR PROPER CHAIN OPERATION. FIELD VERIFY OPERATING SYSTEM
CLEARANCES.
6. REMOVE EXISTING ABANDONED 75 KWA TRANSFORMER MOUNTED AT SECOND WINDOW
LEVEL IN HANGAR #2.
7. EXISTING TRANSFORMER AND PANEL BOARD MOUNTED ON WALL BELOW WINDOWS.
RELOCATE PANEL AND TRANSFORMER 6" FROM WALL ON UNISTRUT SUPPORTS. EXTEND
EXISTING WIRING TO NEW LOCATION.
8. (4) EXISTING CONDUITS IN THE NORTHEAST CORNER OF THE HANGAR #2 TO BE
RELOCATED ABOVE THE RELOCATED STORM PIPE. COORDINATE EXACT LOCATION WITH H.C.
| G-101 with OPTION |
| A-001 |
| Sheets |
| A-001 - ABBREVIATIONS & SYMBOLS |
| A-101 - FLOOR PLAN |
| A-201 - EXTERIOR ELEVATIONS |
| A-202 - EXTERIOR SIDE ELEVATIONS |
| A-601 - WINDOW SCHEDULE |
| A-602 - DETAILS |
| A-603 - DETAILS |
| G-101 - COVER SHEET |
| A-101 |
| Sheets |
| A-001 - ABBREVIATIONS & SYMBOLS |
| A-101 - FLOOR PLAN |
| A-201 - EXTERIOR ELEVATIONS |
| A-202 - EXTERIOR SIDE ELEVATIONS |
| A-601 - WINDOW SCHEDULE |
| A-602 - DETAILS |
| A-603 - DETAILS |
| G-101 - COVER SHEET |
| A-201 with OPTION |
| A-202 with OPTION |
| A-601 |
| Sheets |
| A-001 - ABBREVIATIONS & SYMBOLS |
| A-101 - FLOOR PLAN |
| A-201 - EXTERIOR ELEVATIONS |
| A-202 - EXTERIOR SIDE ELEVATIONS |
| A-601 - WINDOW SCHEDULE |
| A-602 - DETAILS |
| A-603 - DETAILS |
| G-101 - COVER SHEET |
| A-602 with OPTION |
| A-603 with OPTION |
| ME-101 |
| Sheets |
| ME101 - MECHANICAL & ELECTRICAL FLOOR PLAN |
File details come from the government source that posted it.