110002_Drawings.pdf

PDF 14 MB Posted

Attached to
Renovate Restrooms F/20016
Solicitation number
FA8601-13-R-0052
Issued by

About this file

Attachments 1-31 to Solicitation

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

NO SCALE

LOWER LEVEL FACILITY FLOOR PLAN - KEY1

G2

G2

N

A1

A1

1,2,3

1,2,3

DEMO/CONST

REF.CEI.

DEMO/CONST

REF.CEI.

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

WOMEN

MEN

WOMEN

MEN

DESIGNED RC/SK DRAWN RC/SK/KL CHECKED SK

COORDINATOR: SK DESIGN CHIEF: AM ENGINEERING CHIEF: MB

FACILITY 20016

PROJECT NO. ZHTV 110002

LOWER LEVEL KEY PLAN

DATE 05 JULY 11

DN

DN

DN

DN

DN

BASEMENT

ROOF

BLDG 20011

DN

G3

NO SCALE

G3

MAIN LEVEL FACILITY FLOOR PLAN - KEY

N

A2

A5

A4

1,2,3

1,2,3

A3

1,2

REF.CEI.

DEMO/CONST

DEMO/CONST

REF.CEI.

DEMO/CONST

REF.CEI.

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DRAWNDESIGNED CHECKED

COORDINATOR: SK DESIGN CHIEF: AM ENGINEERING CHIEF: MB

DESIGNED RC/SK DRAWN RC/SK/KL CHECKED SK

FACILITY 20016

PROJECT NO. ZHTV 110002

MAIN LEVEL KEY PLAN

DATE 05 JULY 11

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKED

P1

VESTIBULE

MEN’S

RESTROOM

WOMEN’S

RESTROOM

VESTIBULE

VESTIBULE

MEN’S

RESTROOM

WOMEN’S

RESTROOM

VESTIBULE

MARK FIXTURE NAME TRAP VENT HW CW REMARKS

WATER CLOSET

URINAL

LAVATORY

SERVICE SINK

4" 2"

2" 2" 1"

1-1/2" �"1-1/4"

3"

P-2

P-3

P-5

EXISTING TO

REMAIN

1 �" 1 �"

1"

�"�"2"

FLOOR DRAIN 3"

WALL HUNG. REFER

TO SPECIFICATIONS.

WALL HUNG. REFER

TO SPECIFICATIONS.

PLUMBING FIXTURE/EQUIP. SCHEDULE

CONNECTION POINT - NEW

TO EXISTING

CHECK VALVE

SHOCK ABSORBER. LETTER DESIGNATES

P.D.I. UNIT RATING

CLEAN OUT

DOMESTIC HOT WATER

DOMESTIC COLD WATER

VENT THRU ROOF

DOMESTIC HOT WATER RETURN

VENT

SANITARY

DCW

DHW

DHWR

SAN

VTR

V

CO

LEGEND

EXISTING DOMESTIC COLD WATER

PIPING

NEW DOMESTIC COLD WATER

PIPING

NEW DOMESTIC HOT WATER

PIPING

EXISTING SANITARY PIPING

NEW SANITARY PIPING

NEW VENT PIPING

WALL CLEAN OUTWCO

"A"

1.

2.

PLUMBING NOTES

COORDINATE WITH WORK OF OTHER TRADES AND CONSTRUCTION

MANAGER TO AVOID INTERFERENCES BEFORE BEGINNING WORK.

FIELD VERIFY EXISTING CONDITIONS.

INSULATE ALL NEW DOMESTIC HOT & COLD WATER PIPING AND

FITTINGS. REFER TO SPECIFICATIONS.

PROVIDE PIPE SLEEVES WHERE NEW PIPING PENETRATES NEW/EXISTING

WALLS.

3.

4.

P-2

P-2

P-2

P-2

P-2

P-2

P-3

P-3

P-3

P-3

P-3

P-3

029.A 028.A

079.A

078.A

N

0 61 3

SCALE: �" = 1’-0"

N

0 61 3

SCALE: �" = 1’-0"

P-3

P-3

P-3

P-3

P-3

P-3

P-2 P-2 P-2 P-2 P-2 P-2

P-3 P-3 P-3 P-3 P-3 P-3 P-3

P-3 P-3 P-3 P-3 P-3 P-3

(APPLIES TO SHT’S P1 THRU P6)

FD-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1

P-1P-1P-1P-1

P-1

REFER TO STACK & RISER DETAILS SHTS. P3 THRU P6 FOR ADDITIONAL

PIPING, VALVES & FITTINGS NOT SHOWN ON PLAN VIEWS.

5.

DHWR

DHW

D H

W R

D H

W D

C W

DCW

P-4A

P-4B SERVICE SINK 3" 2" �" �"

WALL HUNG. REFER

TO SPECIFICATIONS.

FLOOR MOUNTED. REFER

TO SPECIFICATIONS.

WALL HUNG. REFER

TO SPECIFICATIONS.

CODED NOTES

PROVIDE NEW PLUMBING FIXTURES AS SHOWN, INCLUDING NEW

SANITARY, VENT, AND DOMESTIC HOT & COLD WATER PIPING,

VALVES & FITTINGS. REFER TO NEW STACK & RISER DIAGRAMS

SHEET P4. PROVIDE FIXTURE SHUT-OFF VALVES, LAVATORY

TRAPS, ETC. PER SPECIFICATION 22 00 00.

1 1

4" SAN DOWN THRU SLAB.

4" VTR

4" VENT UP TO FIRST FLOOR AND 5" SAN DOWN FROM FIRST FLOOR.

WCO

WCO

CO

CO

CO

CO CO

RESTROOMS 78 &79 PLUMBING PLAN

RESTROOMS 28 & 29 PLUMBING PLAN

GATE VALVE

EXITING DOMESTIC HOT WATER

PIPING

EXISTING VENT PIPING

P-5

P-5

FACILITY 20016

PROJECT NO. ZHTV 110002

BASEMENT PLUMBING PLAN

JP JP

FD-1

FD-1

FD-1 FD-1

ADA ELECT.

WATER COOLER

APPROXIMATELY 8’ A.F.

APPROXIMATELY 8’ A.F.

A.F. ABOVE FLOOR

ABOVE SUSP.

CEILING

ABOVE SUSP. CEILING

(APPLIES TO SHT’S P1 THRU P6)

PROVIDE WALL ACCESS PANELS TO ACCESS CLEANOUTS.

WALL HUNG. REFER

TO SPECIFICATIONS.

05 JUL 11CJT

COORDINATOR: SK DESIGN CHIEF: AM ENGINEERING CHIEF: MB

I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKED

0 1’

SCALE: 1/4 " = 1’-0"

3’ 6’

P2

LACTATION

ROOM

WOMEN’S

RESTROOM

151.A

MEN’S

RESTROOM

152.A

VESTIBULE

0 1’

SCALE: 1/4 " = 1’-0"

3’ 6’

0 1’

SCALE: 1/4 " = 1’-0"

3’ 6’

MEN’S

RESTROOM

141.A

VESTIBULE

JANITOR’S

CLOSET

141.B

142.B

LACTATION

ROOM

WOMEN’S

RESTROOM

142.A

VESTIBULE

WCO

WCO

WCO

WCO

WCO

CO

CO

CO

CO

CO

P-2

P-2

P-2

P-2

P-2

P-2

P-2

P-2

P-2

P-2

P-2

P-2

P-2

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1 P-1 P-1

P-1 P-1 P-1 P-1

P-3

P-3

P-3

P-3

P-3

P-3

P-3

P-3

P-3

P-3

P-3

P-3

CODED NOTES

PROVIDE NEW PLUMBING FIXTURES AS SHOWN, INCLUDING NEW

SANITARY, VENT, AND DOMESTIC HOT & COLD WATER PIPING,

VALVES & FITTINGS. REFER TO NEW STACK & RISER DIAGRAMS

SHEET P4. PROVIDE FIXTURE SHUT-OFF VALVES, LAVATORY

TRAPS, ETC. PER SPECIFICATION 22 00 00.

CO

WCO

�" DHW UP FROM BSMT.

2" DCW UP FROM BSMT.

�" DCW UP FROM BSMT & 1�" SAN DOWN TO BSMT.

1 �" DHW & 3" DCW UP FROM BSMT.

1�" DHW & 2�" DCW UP FROM BSMT.

4" SAN DOWN THRU FLOOR.

3" SAN DOWN THRU FLOOR.

4" SAN DOWN THRU FLOOR & 4" VTR.

4" VTR.

2" SAN DOWN THRU FLOOR.

FACILITY 20016

PROJECT NO. ZHTV 110002

FIRST FLOOR PLUMPING PLANS

RESTROOMS 119 & 120 PLUMBING PLAN

RESTROOMS 141 & 142 PLUMBING PLAN

RESTROOMS 151 & 152 PLUMBING PLAN

N

N

120.A

VESTIBULE

JANITOR’S

CLOSET

119.A

VESTIBULE

WOMEN’S

RESTROOM

W C

O W

C O

P-2

P-1P-1P-1

P-1 P-1 P-1

P-2 P-2

P-3

P-3

P-3

P-3

P-3 P-3 P-3 P-3

P-3 P-3 P-3

P-3 P-3 P-3

P-3 P-3 P-3

N

P-4A

P-4A

P-4B

P-5

P-5

P-5

FD-2

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

FD-1

1�" DHW & 2 �" DCW UP FROM BSMT.

MEN’S

RESTROOM

MEN’S

RESTROOM

ABOVE SUSP. CEILING

ABOVE SUSP.

CEILING

CAP 3" SAN ABOVE FLOOR.13

JP JP CJT 05 JUL 11

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-3

P-3

P-3

P-3

P-3

P-3

P-2

P-2

P-2

P-2

P-2

P-2

P-3

P-3

P-3

P-3

P-3

P-3

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-3

P-3

P-3

P-3

P-3

P-3

P-2

P-2

P-2

P-2

P-2

P-3

P-3

P-3

P-3

P-3

P-3

P-1

P-1

P-1

P-1

P-2

P-1

P-1

P-1

P-1

P-1

DCW

DHW

DCW

DCW

DCW

DCW

DCW

DHW

DHW

DHW

DHWR

DCW

DCW

DCW

DHWR

DCW

DCW

DCW

DHW

DHW

DHW

DHW

P-5

P-4A

P-4A

1 �"

2 �"

2"

2" 1"

2"

1 �"

2"

1"

1"

1"

1"

1"

1"

1 �"

2"

2"

1"

1"

2"

2 �"

2"

2 �"

2"

1 �"

2"

1"

1"

1"

1 �"

1"

2 �"

NO SCALE

NO SCALE

RISER DIAGRAM

RESTROOMS 78 & 79

RISER DIAGRAM

RESTROOMS 28 & 29

P-5

1 �"

1 �"

1 �"

1"

3"

3"

2"

1"

"D"

"D"

"D"

"D"

"C"

"D"

"D"

"B"

"B"

"A"

"A"

"C"

"C"

"D"

"D"

"B""B"

"B"

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKED

P3

FACILITY 20016

PROJECT NO. ZHTV 110002

BASEMENT RISER DIAGRAMS

JP JP

1"

CJT 05 JUL 11

P-3

P-3

P-3

P-3

P-2

P-3

P-3

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-2

P-2

P-2

P-2

P-2

P-3

P-3

P-3

P-3

P-3

P-3

P-3

P-3

P-1 P-1

P-1 P-1

P-1 P-1

P-2

P-2

P-2

D C

W

DCW

DCW

DHW

DHW

DCW

DHW

DHW

DCW

DHW

DCW

DHW

DHWR

DCW

DHW

DHWR

P-1

P-1

P-1

P-1

DHW

DCW

P-3

P-3

P-1

P-1

P-1

P-3

P-3 P-3

P-3

P-3

P-3

P-3

P-3

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-2

P-2

P-2

P-2

P-2

P-2

DCW

DHW

DCW

DHW

DCW

DHW

DCW

DHWDHWR

D C

W

D H

W

P-4A

P-

4B DCW

P-3

P-3

P-3

P-3

P-3

P-3

P-3

2"

2 �"

2"

2"

1 �"

1 �"

1"

2"

2"

1"

1 �"

2"

2 �"

1"

1"

1 �"

1 �"

1"

1 �"

2"

1 �"

2"

1 �"

2"

2"

2"

2"

2 �" 2 �"

2"

2"

1 �"

2"

1"

2"

2"

1"

1 �"

1 �"

2"

2"

1 �"

1"

NO SCALE

NO SCALE

RISER DIAGRAM

RESTROOMS 151 & 152

RISER DIAGRAM

RESTROOMS 119 & 120

NO SCALE

RISER DIAGRAM

RESTROOMS 141 & 142

3"

3"

1 �"

1 �"

1"

3"2 �"

"C"

P-

1 �"

2"

2"

2"

"D"

"D"

"D"

"B"

"B"

"B"

"D"

"C"

"C"

"B"

"A"

"A"

"A"

"A"

"A"

"A"

"A"

"A"

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKEDJP JP

P4

FACILITY 20016

PROJECT NO. ZHTV 110002

FIRST FLOOR RISER DIAGRAMS

1 �"

1 �"

P- 4A

P-

P-

1ST 1ST

1ST

1ST

1ST

1ST

1ST

1ST

1ST

1 �"

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

NO SCALE

STACK DIAGRAM

RESTROOMS 78 & 79

P-3

P-3

P-3

P-3

P-3

P-3

P-2

P-2

P-2

P-2

P-2

P-2

P-3

P-3

P-3

P-3

P-3

P-3

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-3

P-3

NO SCALE

STACK DIAGRAM

RESTROOMS 28 & 29

P-3

P-3

P-3

P-3

P-2

P-2

P-2

P-2

P-2

P-2

P-3

P-3

P-3

P-3

P-3

P-3

SEWAGE

EJECTOR

FD-1

FD-1

3"

FD-1

FD-1

BSMT

BSMT

BSMT

1ST

1ST

BSMT

BSMT

1ST

BSMT

WCO

WCO

CO

CO

CO

CO

CO

P-4A

P-4A

CO

1ST

4" UNDER

SLAB

4" UNDER

SLAB

3" UNDER

SLAB

5" UNDER

SLAB

5" UNDER

SLAB

4"

4"

4" UNDER

SLAB

4"

4"

4"

4"

4"

3"

3"

3"UNDER

SLAB

4" UNDER

SLAB

4" UNDER

SLAB

5" UNDER

SLAB

4"

3"

4"

4"

4"

5" UNDER

SLAB

3"

3"

3"

3"

3"

3"

3"

3"

3"

3"

4"

3"

4"

3"

3"

4"

4"

4"

4"

4"

3"

3"

1 �"

1 �"

3"

3"

ACCESS COVER

CLEANOUT PIPE

CLEANOUT TEE

18 GAUGE ROUND

GALVANIZED STEEL

NO SCALE

WALL CLEANOUT DETAIL

FINISHED OR

EXTERIOR WALL

5"

4"

4" VTR

4" VTR

BSMT

TYP.

TYP.

BSMT

TYP.

1 �"

P-5

1 �" P-5

1 �"

3"

2"

3"

3"

3"

2"

3"

3"

3"

CO

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKEDJP JP

P5

FACILITY 20016

PROJECT NO. ZHTV 110002

BASEMENT STACK DIAGRAMS

TYP.

FROM RESTROOMS

151 & 152

P-3

P-3

P-3

P-3

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1 P-1

P-2 P-3

P-2 P-3

P-2 P-3

P-2

NO SCALE

STACK DIAGRAM

RESTROOMS 151 & 152

P-1

P-2

P-2

P-1

P-1

P-1

FD-1

FD-1

WCO

WCO

P-3

P-3

P-3

P-1

P-2

P-1

P-3

P-3

P-3

P-3

P-3

P-3

FD-1

P-3

P-3

P-3

FD-1

P-1

P-1

P-1

P-1

P-3

P-3

P-3

P-3 P-3

P-3 P-3

P-2

P-3

P-2

P-3

P-2

P-3

P-3

P-2

P-2

P-2

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

P-1

FD-1

NO SCALE

NO SCALE

STACK DIAGRAM

RESTROOMS 141 & 142

P-4

P-5

P-4

FD-1

WCO

P-4

P-5

CO

CO

CO

CO

CO

CO

CO

CO

CO

1ST

1ST

1ST

1ST

1ST

1ST

1ST

1ST

1ST

1ST

1ST

CO

CO

WCO

WCO

WCO

1ST

TYP.

1ST

TYP.

1ST

STACK DIAGRAM

RESTROOMS 119 & 120

FD-1

FD-1

4"

4"

4"

4"

1ST4"

4"

4"

4"

3"

2"

2"

3"

3"UNDER

FLOOR

4"

3"UNDER

FLOOR

3"

1 �"

3"

2"

2"

3"

4" VTR

4" UNDER

FLOOR

4"

3"

4"3"

4"

4"

3"

4"

4"

5"

3"

3"

3"

3" 3"

3"

4" UNDER

FLOOR

4"

4"

4"

3"

3"

2" 2"

3"

3"

3"

4" VTR

4"

1 �"

2"

2"

4"

4" UNDER

FLOOR

4"

4"

4" UNDER

FLOOR

4"

4"4"

3"

3"

3"

3"

3"

4"

4"

2"

2"

2"

4"

WCO

WCO

3"

3"

3"

3"

4"

2 �"

2 �"

2 �" VTR

4" VTR

3"

3"

3"

3"

3"

CO

WCO

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKEDJP JP

P6

FACILITY 20016

PROJECT NO. ZHTV 110002

FIRST FLOOR STACK DIAGRAMS

4"

4"

P-5

1ST 1 �"

1 �"

P-2

P-2

UP

UP

UP

UP

UP

UP

UP

UP

UP

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKEDJP JP

NO SCALE

WOMEN

MEN

WOMEN

MEN

BASEMENT SANITARY INSPECTION PLAN

EXISTING SEWAGE

EJECTOR

N

PROVIDE TV INSPECTION OF SANITARY LINE FROM

RESTROOMS TO 8" SANITARY LINE TO DETERMINE

CURENT STATE OF LINE.

8"

6"

6"

5"

6"

8"

P7

FACILITY 20016

PROJECT NO. ZHTV 110002

BASEMENT SANITARY INSPECTION PLAN

2 PROVIDE TV INSPECTION OF SANITARY LINE FROM

SEWAGE EJECTOR TO 8" SANITARY LINE TO DETERMINE

CURENT STATE OF LINE.

CODED NOTES

DN

DN

DN

DN

BASEMENT

ROOF

BLDG 20011

DN

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKEDJP JP

NO SCALE N P8

WOMEN

WOMEN

WOMEN

MEN

MEN

MEN

PROVIDE TV INSPECTION OF SANITARY LINE FROM

RESTROOMS TO 8" SANITARY LINE TO DETERMINE

CURENT STATE OF LINE.

PROVIDE TV INSPECTION OF SANITARY LINE FROM

RESTROOMS TO 6" SANITARY LINE TO DETERMINE

CURENT STATE OF LINE.

PROVIDE TV INSPECTION OF SANITARY LINE FROM

RESTROOMS TO SANITARY MANHOLE TO DETERMINE

CURENT STATE OF LINE.

6"

4"

4"

5" SANITARY DOWN

TO BASEMENT

5"

4"

SANITARY

MANHOLE

FIRST FLOOR SANITARY INSPECTION PLAN

CODED NOTES

FACILITY 20016

PROJECT NO. ZHTV 110002

FIRST FLOOR SANITARY INSPECTION PLAN

I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKED

M1

VESTIBULE

MEN’S

RESTROOM

WOMEN’S

RESTROOM

VESTIBULE

VESTIBULE

MEN’S

RESTROOM

WOMEN’S

RESTROOM

VESTIBULE

028029

029.A 028.A

079.A

078.A

N

0 61 3

SCALE: �" = 1’-0"

N

0 61 3

SCALE: �" = 1’-0"

EXISTING DUCTWORK TO REMAIN

LEGEND

JP JP

FACILITY 20016

PROJECT NO. ZHTV 110002

BASEMENT HVAC PLANS

RESTROOMS 78 & 79 HVAC PLAN

RESTROOMS 28 & 29 HVAC PLAN

NEW WORK

EXHAUST GRILLE

ROOF MOUNTED EXHAUST FAN

EF EXHAUST FAN

(APPLIES TO SHT’S M1 THRU M3)

1.

2.

MECHANICAL NOTES

REMOVE ALL EXHAUST AIR DIFFUSERS IN RESTROOMS.

PROVIDE NEW EXHAUST AIR DIFFUSERS AS SHOWN. SEE

SCHEDULE THIS SHEET.

3. CONTRACTOR SHALL CLEAN ALL RESTROOM DUCTWORK.

CFM MAX NEG.

STATIC

PRESSURE

(in. w.g.)

FLOOR

PLAN

SYMBOL

MAX

NOISE

CRITERIA

(NC)

NOMINAL INLET

DUCT SIZE

(in x in)

MODEL

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

TITUS MODEL

50 F EGGCRATE

1" X 1" X 1" GRID

OR EQUAL

13 2560

1 1

24"x 12" DUCT UP

24"x 12"

DUCT UP

EXHAUST GRILLE SCHEDULE

SUSPENDED CEILING

NO SCALE

TYPICAL RETURN AIR GRILLE DETAIL

BALANCING DAMPER

DUCT SIZE AS INDICATED

INLET DUCT SIZE

(SEE SCHEDULE THIS SHEET)

RETURN AIR

MAIN

RETURN AIR

GRILLE

TRANSITION TO RETURN AIR GRILLE

WIDTH

10 x 6

14 x 8

10 x 6

10 x 6

14 x 8

14 x 8

14 x 10

14 x 8

14 x 10

12 x 8

10 x 8

10 x 6

8 x 4

MAT.

AL.

COLOR

WHITE

DUCTWORK AND FAN SIZES SHOWN SHALL BE CONSIDERED AS

APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY ALL

REQUIRED DIMENSIONS, AND ALL MATERIAL REQUIREMENTS

PRIOR TO ORDERING.

(APPLIES TO SHT’S M1 THRU M3)

CONNECTION POINT - NEW

TO EXISTING

TYP.

TYP.

I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKED

0 1’

SCALE: 1/4 " = 1’-0"

3’ 6’

M2

FACILITY 20016

PROJECT NO. ZHTV 110002

FIRST FLOOR HVAC PLANS

LACTATION

ROOM

WOMEN’S

RESTROOM

151.A

MEN’S

RESTROOM

152.A

VESTIBULE

0 1’

SCALE: 1/4 " = 1’-0"

3’ 6’

JP JP

RESTROOMS 151 & 152 HVAC PLAN

RESTROOMS 141 & 142 HVAC PLAN

RESTROOMS 119 & 120 PLAN

N

N

N

0 1’

SCALE: 1/4 " = 1’-0"

3’ 6’

TYP.

TYP.

TYP.

20"x 20"

DUCT UP

14"x 14"

DUCT UP

20"x 20"

DUCT UP

I

V

IL

ENGI

N

E E

R

US AF

W PAFB

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

DATEDRAWNDESIGNED CHECKEDJP JP

A

20011

56789101112131415

N.I.C.

N.I.C.

N.I.C.

N.I.C. N.I.C.

N.I.C.

MODEL

SCALE: �" = 1’-0"

ORTH

ROOF HVAC PLAN

TAG

N

M

L

K

J

I

H

G

F

E

D

C

B

A

RMS

SERVED

TYPE CFM TOTAL STATIC

PRESSURE

MIN MOTOR

HP

VOLTS PHASE HERTZ

EXHAUST FAN SCHEDULE

EF-1

EF-3

EF-5

EF-6

141, 142

28,29

119,120

151, 152,78,79

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

CODED NOTES

REPLACE EF-1. SEE SCHEDULE THIS SHT.

REPLACE EF-3. SEE SCHEDULE THIS SHT.

REPLACE EF-5. SEE SCHEUDLE THIS SHT.

REPLACE EF-6. SEE SCHEDULE THIS SHT.

FACILITY 20016

PROJECT NO. ZHTV 110002

ROOF HVAC PLANS

M3

UNFUSED DISCONNECT SWITCH

REMOVABLE HOUSING

BASE

BACKDRAFT DAMPERS

RUN POWER LEADS IN CORNER INSIDE CURB

SECURE FAN TO CURB WITH SHEET

METAL SCREWS 6" O.C. ALL AROUND

ALUMINUM

BIRDSCREEN

NO SCALE

TYPICAL ROOF MOUNTED EXHAUST FAN DETAIL

MFGR’S EXTENDED PRE-FAB CURB

STANDING SEAM

METAL ROOF

FLASHING AND

CAULK ALL AROUND

PROVIDE W/GRAVITY BACKDRAFT DAMPER

PROVIDE W/BIRDSCREEN

REMARKS

1, 2

1, 2

1, 2

1, 2

GREENHECK

GB-180-5

GREENHECK

GB-180-3

GREENHECK

GB-220-7

GREENHECK

GB-101-3