Att.10_260004_Drawings.pdf
PDF 4 MB Posted
- Solicitation number
- FA813727R0001
About this file
This file is a 35% Design set of construction documents for a structural repair project at Tinker Air Force Base, Oklahoma. The project, identified as WWYK260004, involves repairs to structural integrity of Building B1134, specifically addressing Post 34 and the North Wall. The work is being managed by the Air Force Materiel Command, 72nd Air Base Wing Civil Engineer Directorate.
The primary scope includes replacing existing wood 5x5 columns with new 6x6 treated Southern Pine No. 2 columns, replacing 2x6 wood diagonal wall braces with treated Southern Pine No. 2 braces, removing and replacing existing metal siding, replacing 2x6 wood girts, removing and replacing wood column footings with new 24"x24"x4'-0" concrete footings, repairing damaged wood truss bottom chords through sandwich reinforcement with 2x4 lumber and nailing, and removing asphalt topping over concrete slab at the north bay and end wall. New work includes providing new metal wall panels matching existing profiles (designed per Metal Store OK MS-Snap, 24 gauge, 16-inch width, Regal White Kynar finish), new wood corner columns and bay posts painted SW 4084 Safety Yellow, new 2x wood wall girts and bracing painted SW 7006 Extra White, providing interior vented openings at the metal wall panel base, and tapering asphalt topping with gradual slope. Design loads specified include roof dead load of 10 PSF and live load of 20 PSF, with snow design criteria including ground snow load of 18 PSF and minimum roof snow load of 15.2 PSF. Concrete specifications require 4000 PSI minimum 28-day compressive strength with air-entraining admixture for freeze-thaw protection, and reinforcing steel shall conform to ASTM A615 Grade 60. All construction work must comply with IBC 2024 Edition and ASCE 7-22 standards. Contractor is responsible for field verification of existing conditions, coordination of demolition and new work sequencing, erection of construction fencing, and repair of any damage to existing grounds or facilities at no additional cost to the government.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - FA813727R0001.pdf | ||
| Wage Determinations.pdf | ||
| Att.9_260004_Submittal Register.pdf | ||
| Att.8_260004_MACB_SOW.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVIEWED BY:
REVIEWED BY:
USING AGENCY:
ASBESTOS EVALUATION:
SAFETY:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
INDUSTRIAL HYGIENE:
DATE:
PROJECT DRAWING INDEX SIGNATURES
CORROSION ENGINEER: (CECE)
CE OPERATIONS: (CECO)
COMMUNICATIONS: (COMM)
CHIEF ENGINEER DIR: (CECE)
CHIEF DESIGN BRANCH: (CECE)
DESIGN MANAGER: (CECE)
ZONE MANAGER:
CONSTRUCTION MANAGEMENT: (CECE)
ENVIRONMENTAL:
BASE CIVIL ENGINEER: (CE)
FIRE DEPARTMENT
GENERAL1. BRAND NAMES: REFERENCE TO SPECIFIC BRAND NAMES
OR COMPANIES IS FOR THE PURPOSE OF ESTABLISHING
MINIMUM QUALITY STANDARDS, IDENTIFICATION AND
GUIDANCE AND IS NOT INTENDED TO LIMIT SELECTION OF
OTHER MANUFACTURERS THAT ARE EQUAL OR EXCEED
THE SPECIFIED ITEMS IN TERMS OF PHYSICAL
PROPERTIES, INCLUDING, COLOR RANGE, FINISH,
DURABILITY, APPEARANCE, PERFORMANCE
CHARACTERISTICS, AND OTHER FACTORS. OTHER
PRODUCTS, MATERIALS, COLORS AND SYSTEMS, MAY BE
SUBMITTED FOR EVALUATION AND
APPROVAL/DISAPPROVAL BY THE CONTRACTING OFFICER.
2. THIS SET OF CONSTRUCTION DOCUMENTS SHALL BE
CONSIDERED AS A WHOLE IN THAT THE GENERAL
CONTRACTOR AND ALL THE SUB-CONTRACTORS ARE
RESPONSIBLE FOR THE INFORMATION PRESENTED ON ALL
SHEETS ON THE SET OF DRAWINGS AND ALL SECTIONS OF
THE SPECIFICATIONS.
3. THE CONTRACTOR IS RESPONSIBLE FOR ERECTING ALL
CONSTRUCTION FENCING AND BARRICADES AS REQUIRED
TO PROTECT CONSTRUCTION MATERIAL AND TO PREVENT
ANY UNAUTHORIZED PERSONNEL FROM ENTERING THE
CONSTRUCTION SITE.
4. ANY DAMAGE TO THE EXISTING GROUNDS OR FACILITIES
CAUSED BY CONSTRUCTION TRAFFIC OR ANY
CONSTRUCTION OPERATION SHALL BE REPAIRED OR
REPLACED BY THE CONTRACTOR TO MATCH OR EXCEED
EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE
GOVERNMENT.
5. ALL WORK NOTED & LOCATED IN THESE DOCS SHALL BE
UNDERSTOOD BY THE CONTRACTOR TO REQUIRE ALL NEW
LABOR & MATERIALS UNLESS SPECIFICALLY NOTED TO BE
"EXISTING" OR "BY OTHERS".
WWYK260004
REPAIR STRUCTURAL INTEGRITY,
B1134, POST 34 & NORTH WALL
KEY PLAN:
GENERAL NOTES:
DISCIPLINE
PROJECT
LOCATION
1 G-101 GENERAL NOTES & VICINITY MAP
SHT.SEQ. SHEET TITLE
OF
TI
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
G-101
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
3\
0_ Su pp or t\0 _3
_D ra w in gs
GE
NE
RA
L N
OT
ES
AN
D
VI
CI
NI
TY
M
AP
01 11
C-101 EXISTING TOPOGRAPHY AND UTILITIES PLAN
C-102 SITE PLAN
S-001 STRUCTURAL GENERAL NOTES
5 S-002 SPECIAL INSPECTIONS
6 S-101 STRUCTURAL FOUNDATION PLAN
7 S-102 STRUCTURAL ROOF FRAMING PLAN
8 S-501 DETAILS
9 AD-101 ARCHITECTURAL DEMOLITION PLAN & PARTIAL PLAN
10 A-101 ARCHITECTURAL NEW WORK PLAN & PARTIAL PLAN
11 A-201 EXTERIOR & INTERIOR ELEVATIONS
RUNWAY 13/31
TAXIWAY E
East Crutcho Creek
Ea st
C ru tc ho
C re ek
Ea st
C ru tc ho
C re ek
Ea st
C ru tc ho
C re ek
East C rutcho C reek
East C rutch o Creek
East Crutcho Creek
11401128
11351107
838837
948-E
948-W
41046
11824
Patrol Rd.
Reserve Rd.
Al er t R d.
To w er R d.
Rapcon Rd.
Mercury Rd.
Po nd
R d.
Mercury Rd.
He rc ul es
R d.
R U
N W
AY
8/
RUNWAY 13/31
TA
XI
W
AY
G
TAXIW
AY H
TAXIWAY B
TAXIWAY C
TAXIWAY M
TA
XI
W
AY
K
TAXIWAY E
TAXIWAY A
TA
XIW
AY E
E
TAXIWAY F
TAXIWAY D
TAXIWAY E
TAXIWAY J
TA
XI
W
AY
G
TAXIWAY A
TAXIW
AY H
TAXIWAY C
TAXIWAY D
TAXIWAY EE
TAXIWAY F
Elm C reek
Crutcho Creek
Kuhlman Creek
Soldier Creek
Kuhlman Creek
Elm C reek
East Crutcho Creek
Elm Creek
El m
C re ek
Elm Creek
Elm C reek
Elm CreekElm C reek
Ku hlm an C re ek
Ea st
C ru tc ho
C re ek
Elm C ree k
West Crutcho Creek
W es t C ru tc ho
C re ek
Elm Creek
Soldier Creek
Elm C reek
Soldier CreekSoldier Creek
Ea st
C ru tc ho
C re ek
Elm Creek
Ea st
C ru tc ho
C re ek
East C rutcho C reek
Soldier Creek
So ld ie r C re ek
East C rutch o Creek
Soldier C reek
Soldier C reek
So ld ie r C re ek
East Crutcho Creek
416506
21222121
59475946
11401128
62540
61089
838837
62509
62528
62523
62501X
43774
62512
62516
62525
3592135916
99999
62543
32101
71086
53902
50414
55300
56601
930G
948-E
911-E
948-W
61019
911-W
33001
35913
62501
65672
930S
45134
43609
42116
62517
62515
62526
62527
62503
62513
61289
62542
62501OK
11289
62501
15930
15908
15904
15904
15908
15908
15904
15904
15908
62502
41046
62501
62514
62501
61018
71089
45134
96022
43120
41157
44045
45815
40592
43610
62522
41163
15930
15930
11824
Arnold St.
Ea st
D r.
SE 74th St
SE 59th St.
Ai r D ep ot
Patrol Rd.
St af f D r.
Reserve Rd.
5th Ave
"A " A ve
M un iti on s R d.
W ar eh ou se R d.
"B " A ve
7th St.
"H " A ve
M cN ar ne y Av e.
Mitchell Ave
Al er t R d.
Co ok
A ve
W es t D r.
"E "A ve
Extender Dr.
Sentry Rd.
34th St.
Twining Dr.
5th Ave.
Jo ne s
Globemaster Dr.
To w er R d.
Vanaman Rd.
In du st ria l B lv d.
So ut h St
1st St.
Do ol itt le
A ve
Pi cn ic R d.
Ja m es D r.
W ol fe D r.
Ai r D ep ot
Ai r D ep ot
"D " A ve
Perimeter Rd.
Rapcon Rd.
Reserve Rd
"L " A ve
Mercury Rd.
1st St.
Br ow n Dr
Po nd
R d.
O ld
A ir
De po t
Airey Dr.
Bradley Dr.
Entrance Road "C"
Entrance Road "A"
"C " A ve
"C " A ve
Vandenberg Dr.
Hi llt op R d.
Do rm ito ry
R d.
Dormitory Rd.
"M " A ve
Chennault Dr.
M itc he ll A ve
Spaatz Dr.
Co m m od ity D r.
Doolittle Ave
W hi te D r.
3rd Ave.
"D " D riv e
Ba ll
Pa rk
R d.
Joint STARS Dr.
Ai r D ep ot
B lv d
Turbine Dr. Turbine Dr.
Central Plant Dr.
6th St.6th St.
Falco n Dr.
Blackb ird
Dr.
W ey la nd
L oo p
Pegasus Dr.
Thunderbolt D r.
Munitions Rd. Ext.
Codding Rd.
Starlifter Dr.
Chidlaw Ct.
Co rs ai r D r.
Ra pt or Ct
N ig ht H aw k
Ct
Ph an to m
D r.
Fr an kl in
Po w er ho us e
Dr
Sk ym as te r D r.
Spaatz Ct.
La w re nc e
M un de ll
Nabors Dr.
In tr ud er
D r.
M cN ic kl e
M ill er D r.
Ta il
Fe at he r D r.
Holden Dr.
Ai re y C ir.
Smith Ct.
Ra ve n Ct
Air Dep ot Ai r D ep ot
Vanaman Rd.
1st St.
1st St.
TAXIWAY F
Ra w li ng s A ve
Mitc he ll A ve
Mercury Rd.
Ra ily ar d
Rd
He rc ul es
R d.
"F " A ve
Pr op ul sio n Dr
Stratofortress Dr.
96021
Arnold St.
TINKER AFB, OK
VICINITY MAP
BASE
OPERATIONS
B240
CONTRACTING
B3
GOTT
GATE
TINKER GATE
PASS & ID B6611
HRUSKOCY
GATE
EAKER GATE
FIRE DEPARTMENT
B117
VANCE
GATE
LIBERATOR GATE
HOPE
GATE
LEGEND
CONTRACTOR
HAUL ROUTE
LANCER
GATE
TRUCK GATE
PIAZZA GATE
BASE CIVIL
ENGINEER
B400
PROJECT
LOCATION
(FUTURE
HAUL ROUTE)
(F
UT
UR
E
HA
UL
R
OU
TE
FUTURE
TRUCK GATE
FUTURE
HAUL ROUTE
OF
TI
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
C-101
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
EX
IS
TI
NG
T
OP
OG
RA
PH
Y
A
ND
U
TI
LIT
IE
S
PL
AN
02 11
GENERAL NOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
C-101
EXISTING TOPOGRAPHY & UTILITIES
SCALE: NTS
PROJECT
LOCATION
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
GENERAL NOTES
KEYNOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
GRIND ASPHALT PAVEMENT AS NEEDED TO ASSURE POSITIVE DRAINAGE
FROM NORTH FACE OF BUILDING TO DRAINAGE DITCH TO THE WEST OF
BUILDING
C-102
SITE PLAN
SCALE: 3/8" = 1'-0"
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
R P
O W
EL
L
C-102
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
SI
TE
P
LA
N
03 11
APPROXIMATE LIMITS
OF ASPHALT GRINDING
(SEE KEYNOTE 1)
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35% DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
L
LU
KE
S-001
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
ST
RU
CT
UR
AL
G
EN
ER
AL
NO
TE
S
04 11
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH LOCAL
STANDARDS AND APPLICABLE PROVISIONS OF THE UFC 3-301-01 (2024).
ANY DEVIATION FROM THE APPROVED CONTRACT STRUCTURAL DRAWINGS
SHALL ONLY BE MADE AFTER WRITTEN APPROVAL BY THE ENGINEER OF
RECORD.
ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE
WORKING DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF
THE ENGINEER OF RECORD AND WORK SHALL NOT PROCEED UNTIL WRITTEN
DIRECTION IS PROVIDED BY THE ENGINEER OF RECORD.
PROJECT SPECIFICATIONS ARE PART OF THE CONSTRUCTION DOCUMENTS AND
ARE TO BE USED IN CONJUNCTION WITH THE PROJECT DRAWINGS.
NOTES AND DETAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THESE
GENERAL NOTES AND TYPICAL DETAILS IN CASE OF CONFLICT.
DETAILS LABELED "TYPICAL" APPLY TO SITUATIONS OCCURRING THAT ARE THE
SAME OR SIMILAR TO THOSE SPECIFICALLY SHOWN. SUCH DETAILS APPLY
WHEREVER THEY OCCUR, EVEN WHEN NOT SPECIFICALLY REFERENCED ON THE
DRAWINGS.
WHERE NO CONSTRUCTION DETAILS ARE SHOWN, NOTED, AND DON'T APPEAR
TO ALIGN WITH TYPICAL DETAILS, CONTACT THE STRUCTURAL ENGINEER OF
RECORD.
IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS
OR DETAILS ON THESE STRUCTURAL DRAWINGS.
ELEVATIONS GIVEN ON THE STRUCTURAL DRAWINGS ARE REFERENCED FROM
FINISHED FLOOR, UNLESS OTHERWISE NOTED.
THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE
FINISHED STRUCTURE, UNLESS OTHERWISE NOTED. THEY DO NOT INDICATE THE
MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL PERFORM
ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKMEN, AND
OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE,
BUT ARE NOT LIMITED TO THE DESIGN, ERECTION, AND REMOVAL OF
TEMPORARY BRACING, SHORING, FALSEWORK, ETC. THE CONTRACTOR SHALL
SUPERVISE AND DIRECT THE WORK AND BE SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND
PROCEDURES. OBSERVATION VISITS BY THE ENGINEER OF RECORD OR THEIR
DELEGATE DO NOT CONSTITUTE INSPECTION OR APPROVAL OF THE ABOVE
ITEMS.
VERIFICATION: THE DETAILING AND DIMENSIONS OF EXISTING STRUCTURES DO
NOT NECESSARILY REPRESENT THE AS-CONSTRUCTED CONDITIONS. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE
CONDITIONS BEFORE STARTING WORK. NOTIFY THE ENGINEER OF RECORD
IMMEDIATELY OF ANY DISCREPANCIES. IN INSTANCES WHERE DISCREPANCIES
ARE IDENTIFIED, WORK SHALL NOT PROCEED UNTIL WRITTEN DIRECTION IS
PROVIDED BY THE ENGINEER OF RECORD.
THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DETAILS,
DIMENSIONS AND SITE CONDITIONS TO AVOID THE INTERFERENCE OF
MATERIALS EMBEDDED IN CONCRETE OR MASONRY INCLUDING BUT NOT LIMITED
TO REINFORCING STEEL, PRESTRESSING STEEL AND HARDWARE,
MISCELLANEOUS STEEL AND CONDUITS.
CONSTRUCTION MATERIALS SHALL BE EVENLY DISTRIBUTED IF PLACED ON
FLOORS OR ROOFS DURING CONSTRUCTION. LOADS SHALL NOT EXCEED THE
DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/OR
BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH.
CONCRETE SLAB ON GRADE IS TO HAVE REACHED IT'S FULL 28-DAY
COMPRESSIVE STRENGTH BEFORE LOADING.
PROVIDE A LIST OF ALL PROPOSED SUBSTITUTIONS AND MANUFACTURER'S ICC
ES REPORTS TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL
BEFORE FABRICATION OR INSTALLATION.
NO STRUCTURAL MEMBER SHALL BE CUT OR MODIFIED FOR PIPES, DUCTS, ETC.,
UNLESS SPECIFICALLY SHOWN ON THESE STRUCTURAL DRAWINGS.
THESE STRUCTURAL DRAWINGS ILLUSTRATE THE NEW STRUCTURAL MEMBERS.
REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR
NON-STRUCTURAL ITEMS WHICH REQUIRE SPECIAL PROVISIONS DURING
CONSTRUCTION OF THE STRUCTURAL MEMBERS.
REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR DEPRESSIONS, SLOPES,
DRAINS, CURBS, PADS, EMBEDDED ITEMS, NON-BEARING PARTITIONS, AND
LOCATION AND DETAILS FOR ALL MISCELLANEOUS HANDRAILS, LADDERS,
HANGERS AND STEEL GRATINGS. REFER TO MECHANICAL AND ELECTRICAL
DRAWINGS FOR SLEEVES AND HANGARS FOR PIPES, DUCTS, AND EQUIPMENT.
SEE PLUMBING, FIRE PROTECTION, MECHANICAL, ELECTRICAL AND
MANUFACTURER'S DRAWINGS FOR TYPE, SIZE, LOCATION, ANCHORAGE
REQUIREMENTS AND PADS FOR ALL EQUIPMENT. MANUFACTURER'S TEMPLATES
SHOWING ANCHOR BOLT LOCATIONS SHALL BE OBTAINED FOR ALL EQUIPMENT.
COORDINATE WITH THE EQUIPMENT SUPPLIER PRIOR TO PLACING SLABS, WALLS
AND FOUNDATIONS.
THESE STRUCTURAL DRAWINGS INDICATE ONLY THE APPROXIMATE LOCATION
OF MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT AS WELL AS THEIR
RELATED AUXILIARY FRAMING NECESSARY TO SUPPORT THE EQUIPMENT. THE
FINAL POSITIONING OF THESE ITEMS IS DEPENDENT UPON THE EQUIPMENT
PROVIDED. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WORK
BETWEEN SUBCONTRACTORS IN THIS REGARD AND PROVIDING NECESSARY
INFORMATION AND DIMENSIONS IN A TIMELY MANNER TO ALL PARTIES INVOLVED.
OBSERVATION VISITS TO THE SITE BY THE ENGINEER OF RECORD OR THEIR
DELEGATE SHALL NOT CONSTITUTE REQUIRED SPECIAL INSPECTIONS NOTED
HEREIN.
THE CONCRETE SLABS ON GRADE HAVE NOT BEEN DESIGNED TO SUPPORT
CONSTRUCTION EQUIPMENT. THE CONTRACTOR IS RESPONSIBLE FOR THE
DESIGN OF THE SLAB WHERE CONSTRUCTION EQUIPMENT IS TO BE PLACED
THAT EXCEED THE DESIGN FLOOR LIVE LOAD. ANY DAMAGE TO THE CONCRETE
SLAB AS A RESULT OF CONSTRUCTION EQUIPMENT IS THE RESPONSIBILITY OF
THE CONTRACTOR AND SHALL BE REPAIRED AT THEIR COST. CONCRETE SLAB
ON GRADE IS TO HAVE REACHED IT'S FULL 28-DAY COMPRESSIVE STRENGTH
BEFORE LOADING.
SHOP DRAWINGS AND PRODUCT DATA
2.
3.
4.
5.
6.
7.
8.
THE REVIEW OF SHOP DRAWINGS AND OTHER SUBMITTALS IS ONLY FOR REVIEW
OF GENERAL COMPLIANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND
THE INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS. IT IS THE
GENERAL CONTRACTOR'S RESPONSIBILITY TO REVIEW THE SHOP DRAWINGS
PRIOR TO SUBMITTING TO THE ARCHITECT. THE GENERAL CONTRACTOR IS
RESPONSIBLE FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND
DIMENSIONS, SELECTING FABRICATION PROCESSES AND TECHNIQUES OF
CONSTRUCTION; COORDINATING THE WORK WITH THAT OF ALL OTHER TRADES;
AND PERFORMING THE WORK IN A SAFE AND SATISFACTORY MANNER.
SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN
ADDITION TO ANY ITEMS REQUIRED BY THE SPECIFICATIONS. THE SUBMITTALS,
TESTING & INSPECTION MATRIX IS PROVIDED AS A GUIDE ONLY, AND MAY NOT BE
ALL-INCLUSIVE. CONSTRUCTION DOCUMENTS SHALL NOT BE REPRODUCED FOR
USE AS SHOP DRAWINGS.
THE GENERAL CONTRACTOR SHALL REVIEW AND STAMP ALL SHOP DRAWINGS
AND PRODUCT DATA FOR CONFORMANCE WITH THE CONSTRUCTION
DOCUMENTS PRIOR TO SUBMITTAL. ANY SHOP DRAWINGS OR PRODUCT DATA
NOT REVIEWED AND STAMPED BY THE GENERAL CONTRACTOR WILL BE
RETURNED WITHOUT REVIEW. THE CONTRACTOR SHALL CLOUD OR FLAG ALL
ITEMS NOT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM THE ORIGINAL CONTRACT
DRAWINGS SHALL BE CLOUDED BY THE MANUFACTURER OR FABRICATOR. THE
STRUCTURAL ENGINEER RESERVES THE RIGHT TO ALLOW OR NOT ALLOW ANY
CHANGES TO THE ORIGINAL CONTRACT DRAWINGS AT ANY TIME BEFORE OR
AFTER SHOP DRAWING REVIEW.
THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS.
ITEMS OMITTED OR SHOWN INCORRECTLY AND WHICH ARE NOT NOTED AS
ALLOWED BY THE STRUCTURAL ENGINEER OR ARCHITECT ARE NOT TO BE
CONSIDERED CHANGES TO THE ORIGINAL CONTRACT DRAWINGS.
SHOP DRAWINGS WILL BE RETURNED FOR RESUBMITTAL IF MAJOR ERRORS OR
OMISSIONS ARE FOUND DURING REVIEW.
SUBMIT NOT MORE THAN FIVE (5) SETS FOR ANY ONE SUBMITTAL. ONE COPY
WILL BE RETAINED BY THE STRUCTURAL ENGINEER AND THE BALANCE
RETURNED.
ALLOW A MINIMUM OF FIVE WORKING DAYS FOR REVIEW OF SHOP DRAWINGS BY
THE STRUCTURAL ENGINEER.
DESIGN CRITERIA
1.
C.
D.
2.
A.
B.
A.
B.
C.
D.
E.
F.
A.
B.
C.
D.
E.
F.
G.
H.
THE DESIGN CRITERIA SHALL CONFORM TO THE PROVISIONS OF THE UFC 3-301-01, AND
STANDARDS REFERENCED THEREIN.
INTERNATIONAL BUILDING CODE (IBC) - 2024 EDITION
TINKER AFB STANDARDS
MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES - ASCE 7-22
RISK CATEGORY OF BUILDING II
DESIGN LOADS:
ROOF DEAD LOAD
ROOF LIVE LOAD
3. SNOW DESIGN CRITERIA:
RISK CATEGORY
GROUND SNOW LOAD, p g MINIMUM ROOF SNOW LOAD, p s SNOW EXPOSURE FACTOR, C e
THERMAL FACTOR, C
SLOPE FACTOR, C s
4. WIND DESIGN CRITERIA:
RISK CATEGORY
DESIGN WIND SPEED (V ULT)
DESIGN WIND SPEED (V ASD)
EXPOSURE CATEGORY
TOPOGRAPHIC FACTOR (K zt) GCpi
GUST EFFECT FACTOR (G)
WIND BASE SHEAR (V W)
CORNER EDGE DISTANCE a = 5'-0", POSITIVE AND NEGATIVE VALUES SIGNIFY PRESSURES ACTING
TOWARD AND AWAY FROM SURFACES, RESPECTIVELY.
10 PSF (TOTAL)
20 PSF (NON-REDUCIBLE)
II
18 PSF
15.2 PSF
1.0 1.2 1.0
II
109 MPH
85 MPH
C 1.0 +/- 0.55 0.85
176 KIPS
BUILDING COMPONENTS AND CLADDING
GROSS WIND PRESSURES (1.0W)
ZONE DESCRIPTION
POSITIVE PRESSURES (PSF)
EFFECTIVE AREA (FT2)
10 100 200 500
NEGATIVE PRESSURES (PSF)
EFFECTIVE AREA (FT2)
10 100 200 500
19 171
ROOF INT
ROOF CORNER
WALL INTERIOR
WALL CORNER
-36 -43
2 ROOF EDGE -67 -38
-77 -43
34 28 34 28
-45 -30
A.
B.
C.
D.
E.
H.
I.
J.
K.
N.
O.
5.
RISK CATEGORY
IMPORTANCE FACTOR, I e
SITE CLASS
Ss
SMS
SM1
SD1
SEISMIC RESISTING SYSTEM
RESPONSE MODIFICATION COEFF (R)
ANALYSIS PROCEDURE
6. FLOOD DESIGN DATA : NOT REQUIRED, NOT IN FLOOD ZONE.
7. ROOF DRAIN LOAD DATA:
A. 15 MINUTE RAIN INTENSITY
B. 60 MINUTE RAIN INTENSITY
II
1.00 D 0.31g
B
LIGHT-FRAME (COLD-FORMED STEEL)
CANTILEVERED COLUMN SYSTEMS DETAILED TO
CONFORM TO THE REQUIREMENTS FOR TIMBER
FRAMES.
27.0 KIPS
0.153 1.5
EQUIVALENT LATERAL FORCE
7.78 IN/HR
3.92 IN/HR
SEISMIC DESIGN CRITERIA:
L.
M.
SEISMIC BASE SHEAR
RESPONSE COEFFICIENT (Cs)
SEISMIC DESIGN CATEGORY (SDC)
F.
G.
DS
S S
19 17 19 17-
-30 -30
1.
t
0.35g 0.23g 0.081g 0.17g 0.11g
A.
B.
SOILS AND FOUNDATIONS
1.
2.
3.
4.
5.
A.
B.
C.
D.
E.
F.
G.
H.
I.
GEOTECHNICAL DESIGN CRITERIA
STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR ANY
GEOTECHNICAL ASPECT OF THIS PROJECT.
CONTRACTOR SHALL EMPLOY A GEOTECHNICAL ENGINEER LICENSED IN THE STATE OF
JURISDICTION TO PERFORM NECESSARY TESTING AND INSPECTIONS FOR
QUALITY CONTROL AND TO ENSURE THAT THE REQUIREMENTS OF THE
GEOTECHNICAL REPORT ARE COMPLIED WITH. TEST REPORTS SHALL BE
SUBMITTED DIRECTLY TO THE ARCHITECT AND ENGINEER FROM THE
GEOTECHNICAL ENGINEER, WITH A COPY TO THE CONTRACTOR.
FILLED EXCAVATIONS OR BURIED STRUCTURES SUCH AS CESSPOOLS, CISTERNS,
EXISTING FOUNDATIONS, ETC., OR ANY UNUSUAL SOILS CONDITIONS
ENCOUNTERED DURING SITE CLEARING OR EXCAVATION SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT IMMEDIATELY. DO NOT PROCEED UNTIL
WRITTEN INSTRUCTIONS TO REMEDY ARE RECEIVED. ABANDONED FOOTINGS,
NEW OR EXISTING UTILITIES, ETC., THAT INTERFERE WITH NEW CONSTRUCTION
SHALL BE REROUTED OR REMOVED AS DIRECTED BY THE ARCHITECT.
SLOPE ALL EXTERIOR FINISHED GRADES AWAY FROM THE BUILDING TO ENSURE
NO PONDING OF WATER OCCURS AROUND BUILDINGS.
SOIL DESIGN PARAMETERS (SHALLOW FOUNDATIONS):
MINIMUM DEPTH OF BOTTOM OF FOOTINGS = 2'-0" BELOW LOWEST ADJACENT
GRADE
MINIMUM WIDTH OF COLUMN FOOTINGS = 2'-0"
FROST DEPTH = 2'-0"
ALLOWABLE NET VERTICAL BEARING PRESSURE FOR ISOLATED/PAD
FOOTINGS = 1500 PSF
COHESION BETWEEN SOIL AND CONCRETE = 130 PSF
PASSIVE EARTH PRESSURE = 100PCF (CLAY)
UNIT WEIGHT = 120 PCF (CLAY)
SOIL SITE CLASS = D
THE FOUNDATION DESIGN IS BASED UPON THE IBC PRESUMPTIVE LOAD-BEARING VALUES.
CAST IN PLACE CONCRETE
1.
2.
A.
C.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301,
"SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" AND ACI 318,
"BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", EXCEPT AS
MODIFIED BY THE CONTRACT DOCUMENTS.
CONCRETE SHALL BE READY MIXED CONCRETE IN ACCORDANCE WITH ASTM C94.
MINIMUM 28 DAY COMPRESSIVE STRENGTH SHALL BE 4000 PSI EXCEPT AS FOLLOWS:
FOUNDATIONS 3,000 PSI
CONCRETE EXPOSED TO FREEZE/THAW CYCLE 4,500 PSI
CEMENT SHALL CONFORM TO ASTM C150, TYPE I, TYPE II,
CONCRETE EXPOSED TO SOIL SHALL HAVE TYPE II CEMENT AND A MAXIMUM W/C
RATIO OF 0.5. AGGREGATE PER ASTM C33. MAXIMUM 4" SLUMP FOR ALL
CONCRETE. DO NOT TAMP SLABS (USE ROLLER BUG, VIBRATING SCREED OR BULL
FLOAT ONLY). CONCRETE CONTAINING SUPERPLASTICIZING ADMIXTURE SHALL HAVE
FIELD-VERIFIED 3" MAXIMUM SLUMP PRIOR TO ADDING ADMIXTURE AND 8" MAXIMUM
SLUMP AT PLACEMENT. MIX DESIGNS SHALL BE DESIGNED BY THE CONCRETE
PRODUCTION FACILITY IN ACCORDANCE WITH ACI 301 AND APPROVED BY THE
STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. PROVIDE AIR-ENTRAINING
ADMIXTURE AT ALL CONCRETE EXPOSED TO FREEZE/THAW CYCLES AT A RATE
ADEQUATE TO PROVIDE 6.0% AIR AT POINT OF PLACEMENT. DO NOT ALLOW AIR
CONTENT OF INTERIOR TROWEL FINISHED SLABS TO EXCEED 3.0%.
CONCRETE SHALL BE FREE OF CALCIUM CHLORIDE. NO FLY ASH ADDITIVES SHALL BE
PERMITTED IN CONCRETE FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE.
WHEN USED, FLY ASH SHALL CONFORM TO ASTM C618, CLASS F OR C. FLY ASH SHALL
NOT REPLACE MORE THAN 25% OF CEMENT BY WEIGHT.
CONTINUOUS SPECIAL INSPECTION: REQUIRED FOR DESIGN STRENGTHS EXCEEDING
2500 PSI.
DO NOT SUBJECT CONCRETE TO ANY PROCEDURE THAT WILL CAUSE SEGREGATION.
DEPOSIT CONCRETE AS NEAR AS PRACTICABLE TO THE FINAL POSITION TO AVOID
SEGREGATION.
CONCRETE FOOTINGS AND PADS MAY BE POURED AGAINST NEAT EXCAVATIONS
PROVIDED THE REQUIRED CONCRETE COVERAGE FOR REINFORCING IS MAINTAINED.
MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED.
MIXING AND DELIVERY AS MEASURED FROM BATCH TIME TO COMPLETION OF
DISCHARGE FROM TRUCK SHALL NOT EXCEED 90 MINUTES. WHEN AIR TEMPERATURE
IS ABOVE 90 DEG F (32 DEG C), REDUCE MIXING, DELIVERY TIME AND DISCHARGE TO
60 MINUTES.
CURE EXPOSED CONCRETE FOR A MINIMUM OF 7 DAYS IN ACCORDANCE WITH ACI
308.1 PROCEDURES IN ORDER TO PREVENT CRACKING. CURE WITH CURING AND
SEALING COMPOUND, MOIST CURING, MOISTURE-RETAINING COVER CURING, OR
COMBINATIONS THEREOF. IF CURING COMPOUND IS USED, APPLY AT A RATE
SPECIFIED BY THE MANUFACTURER. CONCRETE SHALL BE MAINTAINED ABOVE 50
DEGREES F AND IN A MOIST CONDITION FOR A MINIMUM OF 7 DAYS AFTER
PLACEMENT.ALL CONCRETE SHALL BE TESTED BY AN INDEPENDENT TESTING AGENCY
AND RESULTS REPORTED TO THE ARCHITECT.
FOR PLACEMENT OF CONCRETE IN EITHER HOT OR COLD WEATHER CONDITIONS
FOLLOW THE ACI STANDARD PROCEDURES.
REINFORCING BARS, ANCHOR BOLTS, REBAR DOWELS, AND OTHER CONCRETE
INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACEMENT OF CONCRETE
AND STABBING INTO WET CONCRETE IS NOT ALLOWED.
CHAMFER: 3/4 INCH ON EXPOSED CORNERS.
REINFORCING
1.
2.
3.
4.
5.
6.
REINFORCING AND ACCESSORIES SHALL BE DETAILED, FABRICATED AND
INSTALLED PER ACI 315, ACI 318 AND CRSI "MANUAL OF STANDARD PRACTICE
FOR REINFORCED CONCRETE CONSTRUCTION.
REINFORCING BARS SHALL BE MADE USING NEW BILLET STEEL IN
ACCORDANCE WITH ASTM A615 GRADE 60 f y = 60 KSI. WELDED WIRE FABRIC PER
ASTM A185, WIRE PER ASTM A82, FABRICATED IN FLAT SHEETS (NOT ROLLED)
WELDING OF REINFORCING IS NOT PERMITTED UNLESS SPECIFICALLY
DETAILED. WELDED SHALL BE ACCORDING TO AWS D1.4.
ALL REINFORCING SHALL BE COLD BENT.
PROVIDE CLASS B SPLICES IN REINFORCING FOR CONTINUOUS REINFORCING.
PROVIDE STANDARD 90 DEGREE HOOKS IN ACCORDANCE WITH ACI 318 UNLESS
SPECIFICALLY DETAILED. REFER TO TYPICAL DETAIL FOR REQUIRED LAP
LENGTHS.
MAINTAIN THE FOLLOWING REINFORCEMENT COVERAGE FOR REINFORCING
STEEL UNLESS NOTED OTHERWISE.
CAST AGAINST OR PERMANENTY
EXPOSED TO SOIL: 3 INCHES
EXPOSED TO SOIL OR WEATHER:
NO. 6 AND LARGER: 2 INCHES
NO. 5 AND SMALLER: 1-1/2 INCHES
NOT EXPOSED TO SOIL OR WEATHER
NO. 11 AND SMALLER 1" WALL, 1-1/2" SLAB
COLUMNS (TO TIES) 1 1/2"
BEAMS (TO STIRRUPS) 1 1/2"
SUSPENDED SLABS 3/4"
ALL OTHER PER LATEST EDITION OF ACI 318
BAR SIZE:
TOP OTHER
#3
#4
#5
#6
#7
#8
#9
#10
#11
BAR SPLICES
CONCRETE f' c
3 KSI
27" 21"
36" 28"
47" 36"
56" 43"
81" 62"
92" 71"
105" 81"
117" 90"
129" 100"
TOP OTHER
4 KSI
25" 19"
33" 25"
39" 30"
48" 37"
70" 54"
81" 62"
91" 71"
100" 77"
112" 87"
TOP OTHER
5 KSI
23" 18"
30" 23"
36" 28"
43" 33"
53" 49"
73" 56"
81" 63"
90" 69"
100" 78"
ONE
LAYER
TWO
LAYERS
15" 15"
21" 23"
30" 35"
43" 66"
58" 90"
87" 135"
111" 171"
140" 217"
173" 268"
MASONRY
REINFORCING BAR SPACINGS GIVEN ARE MAXIMUM ON CENTERS.
SECURELY TIE ALL BARS IN POSITION BEFORE PLACING CONCRETE.
REINFORCING BAR HOOKS SHALL BE STANDARD ACI HOOKS UNLESS NOTED
OTHERWISE.
NOTES:
- #14 AND #18 BARS CANNOT BE LAP SPLICED.
- FOR LIGHTWEIGHT CONCRETE MULTIPLY SPLICE LENGTH BY 1.3.
- FOR EPOXY-COATED REINFORCEMENT, MULTIPLY SPLICE LENGTH
BY 1.5.
- FOR CLEAR SPACING BETWEEN SPLICES OF LESS THAN 2 BAR
DIAMETERS, OR CLEAR COVER OVER BARS BEING SPLICED
LESS THAN 1 BAR DIAMETER, MULTIPLY SPLICE LENGTH BY 1.5.
- SPLICE LENGTHS SHOWN OR CALCULATED ARE MINIMUMS. ROUND
UP AS REQUIRED TO ACHIEVE MINIMUM SPLICE LENGTH.
- TOP BARS ARE DEFINED AS ANY HORIZONTAL REINFORCEMENT
PLACES SUCH THAT MORE THAN 12" OF FRESH CONCRETE IS
CAST BELOW THE BARS BEING PLACED.
7.
8.
B. SLABS 4,000 PSI
1.
2.
A.
B.
3.
4.
5.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STRUCTURAL DESIGN,
INSTALLATION AND ANCHORAGE OF THE FOLLOWING ITEMS NOT DESIGNED BY
TEPA COMPANIES. SUBMIT SHOP DRAWINGS AND STRUCTURAL
CALCULATIONS TO THE ENGINEER OF RECORD AND AUTHORITY HAVING
JURISDICTION DEMONSTRATING THAT A COMPLETE LOAD PATH HAS BEEN
ESTABLISHED AND CODE REQUIREMENTS HAVE BEEN MET. INCLUDE LOADS,
PRODUCT DATA, TECHNICAL INFORMATION, MANUFACTURER'S WRITTEN
REQUIREMENTS AND AGENCY APPROVALS, AS APPLICABLE. THE SHOP DRAWINGS
AND STRUCTURAL CALCULATIONS SHALL BE SIGNED AND SEALED BY A QUALIFIED
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT.
THE FOLLOWING ARE DELEGATED DESIGN ITEMS:
SHORING
MODIFICATIONS OF WOOD STRUCTURAL MEMBERS.
COORDINATE ALL CONSTRUCTION WITH DELEGATED DESIGN ITEMS.
DELEGATED DESIGN ITEMS SHALL NOT BE INSTALLED UNTIL ALL RELATED
SUBMITTALS HAVE BEEN REVIEWED AND APPROVED BY THE ENGINEERING OF
RECORD AND AUTHORITY HAVING JURISDICTION.
REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION NOT INCLUDED ABOVE.
DELEGATED DESIGN ITEMS
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
L
LU
KE
S-002
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
GE
NE
RA
L N
OT
ES
SP
EC
IA
L I
NS
PE
CT
IO
NS
05 11
& AND
@ AT
AB ANCHOR BOLT
ABV ABOVE
ADDL ADDITIONAL
ALT ALTERNATE
ARCH ARCHITECT(URAL)
ATR ALL THREAD ROD
B/ BOTTOM OF
BF BRACED FRAME
BLDG BUILDING
BLKD BLOCKED
BLKG BLOCK(ING)
BLW BELOW
BM BEAM
BN BOUNDARY NAILING
BRG BEARING
BTM BOTTOM
BP BASE PLATE
C= CAMBER
CFS COLD-FORMED STEEL
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY
UNIT
CNTR CENTER(ED)
COL COLUMN
CONC CONCRETE
CONST CONSTRUCT(ION)
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
CSK COUNTERSINK
d PENNY(NAILS)
DBL DOUBLE
DIA, Ø DIAMETER
DO DITTO
DWG DRAWING(S)
DWL DOWEL(S)
(E) EXISTING
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EMBED EMBED(ED)(MENT)
EN EDGE NAILING
EQ EQUAL
EQUIP EQUIPMENT
ESR EVALUATION SERVICE
REPORT
ES EACH SIDE
EW EACH WAY
EXT EXTERIOR
FDN FOUNDATION
FF FINISHED FLOOR
FG FINISH GRADE
FLR FLOOR
FN FIELD NAILING
FO FACE OF
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUD
FP FULL PENETRATION
FRMG FRAMING
FS FAR SIDE
FT FOOT(FEET)
FTG FOOTING
GA GAUGE(GAGE)
GALV GALVANIZE(D)
GL GLUE LAMINATE
GLB GLUE LAMINATED
BEAM
GR GRADE
GYP GYPSUM
H HORIZONTAL
HD HOLDOWN
HDG HOT DIPPED
GALVANIZED
HDR HEADER
HGR HANGER
HK HOOK
HSS HOLLOW STRUCTURAL
SECTION
HT HEIGHT
IAPMO INTERNATIONAL
ASSOCIATION OF
PLUMBING AND
MECHANICAL
OFFICIALS
ID INSIDE DIAMETER
IJ ISOLATION JOINT
IN INCH(ES)
INT INTERIOR
JST JOIST
JT JOINT
L LONG (LENGTH)
LB POUND(S)
LLH LONG LEG
HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LW LIGHTWEIGHT
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
(N) NEW
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
P/C PRECAST
PEMB PREENGINEERED
METAL BUILDING
PLATE
PLY PLYWOOD
PLF POUNDS PER LINEAR
FOOT
PNL PANEL
P/S PRESTRESS(ED)
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT PRESSURE TREATED
R RADIUS
RBS REDUCED BEAM
SECTION
RCP REINF CONC PIPE
REF REFERENCE
REINF REINFORCE(ING)(MENT
REQD REQUIRED
RF ROOF
RO ROUGH OPENING
RTU ROOF TOP UNIT
SC SLIP CRITICAL
SCHED SCHEDULE
SHTG SHEATHING
SIM SIMILAR
SMS SHEET METAL SCREW
SOG SLAB ON GRADE
SPEC SPECIFICATION(S)
SQ SQUARE
STD STANDARD
STGR STAGGER(ED)
STIFF STIFFEN(ER)
STL STEEL
STRUCT STRUCTURAL
SYMM SYMMETRICAL
SW SHEAR WALL
T&B TOP & BOTTOM
T&G TONGUE & GROOVE
THK THICK(NESS)
THRD THREAD(ED)
TN TOE NAIL(ING)
T/CONC TOP OF CONCRETE
T/PARAPET TOP OF PARAPET
T/STEEL TOP OF STEEL
TOW TOP OF WALL
TOF TOP OF FTG/FDN
T/ TOP OF
TRANS TRANSVERSE
TYP TYPICAL
UNBLKD UNBLOCKED
UNO UNLESS NOTED
OTHERWISE
V VERTICAL
VIF VERIFY IN FIELD
W WIDTH (WIDE)
W/ WITH
WD WOOD
W/O WITHOUT
WP WORK POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
X-STG EXTRA STRONG
XX-STG DOUBLE EXTRA
STRONG
YD YARD
ABBREVIATIONS
STATEMENT OF QUALITY ASSURANCE /
SPECIAL INSPECTIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
QUALITY ASSURANCE / SPECIAL INSPECTION IS REQUIRED IN ACCORDANCE WITH THE
UFC 3-301-01/IBC 2024 AS SUMMARIZED BELOW.
THE SPECIAL INSPECTORS MUST BE QUALIFIED TO PERFORM THE TYPES OF
INSPECTION SPECIFIED.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INFORM THE SPECIAL INSPECTOR
OR INSPECTING AGENCY AT LEAST ONE WORKING DAY PRIOR TO PERFORMING ANY
WORK THAT REQUIRES SPECIAL INSPECTION. ALL WORK PERFORMED WITHOUT
SPECIAL INSPECTION IS SUBJECT TO REMOVAL.
THE SPECIAL INSPECTOR(S) SHALL OBSERVE THE INDICATED WORK FOR COMPLIANCE
WITH THE CONTRACT DOCUMENTS AND SUBMIT RECORDS OF INSPECTION TO THE
ARCHITECT, ENGINEER OF RECORD AND AUTHORITY HAVING JURISDICTION.
SPECIAL INSPECTIONS SHALL BE PERFORMED BY A CERTIFIED OR QUALIFIED SPECIAL
INSPECTOR(S), AS DETERMINED AND TO THE SATISFACTION OF THE ARCHITECT,
ENGINEER OF RECORD AND AUTHORITY HAVING JURISDICTION.
PERIODIC SPECIAL INSPECTION IS DEFINED AS THE PART-TIME OR INTERMITTENT
INSPECTION OF THE WORK BY AN APPROVED INSPECTOR WHO IS PRESENT IN THE
AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT THE COMPLETION
OF WORK. CONTINUOUS SPECIAL INSPECTION IS DEFINED AS THE FULL-TIME
INSPECTION OF THE WORK BY AN APPROVED INSPECTOR WHO IS CONTINUOUSLY
PRESENT AND MONITORING THE WORK PERFORMED. IN ALL CASES, THE INSPECTION
SHALL BE COORDINATED AND PERFORMED SO THAT WORK CAN BE CORRECTED PRIOR
TO OTHER RELATED WORK PROCEEDING AND COVERING THE INSPECTED WORK.
ASSOCIATED TESTING SHALL BE PERFORMED AS INDICATED IN THE FOLLOWING TABLES
BY AN APPROVED AND ACCREDITED AGENCY AS DETERMINED AND TO THE
SATISFACTION OF THE ARCHITECT, ENGINEER OF RECORD AND AUTHORITY HAVING
JURISDICTION.
SPECIAL INSPECTION AND ASSOCIATED TESTING REPORTS SHALL BE SUBMITTED TO
THE ENGINEER OF RECORD, CONTRACTOR, AUTHORITY HAVING JURISDICTION, AND
ARCHITECT WITHIN ONE WEEK OF INSPECTION OR WITHIN ONE WEEK OF TEST
COMPLETION.
AT THE CONCLUSION OF CONSTRUCTION, A FINAL REPORT SHALL BE SUBMITTED BY
THE SPECIAL INSPECTOR(S) WHICH DOCUMENTS THE REQUIRED SPECIAL INSPECTIONS
AND CORRECTION OF PREVIOUSLY NOTED DISCREPANCIES. THE FINAL REPORT SHALL
BE SUBMITTED TO THE ENGINEER OF RECORD, CONTRACTOR, AUTHORITY HAVING
JURISDICTION AND ARCHITECT.
WORK REQUIRING SPECIAL INSPECTION THAT IS INSTALLED OR COVERED WITHOUT THE
APPROVAL OF THE SPECIAL INSPECTOR IS SUBJECT TO REMOVAL OR EXPOSURE.
REFER TO THE FOLLOWING TABLES AND SPECIFICATIONS FOR SPECIFIC
INSPECTION/TESTING REQUIREMENTS AND FREQUENCIES.
DEFINITION OF "PERIODIC" AND "CONTINUOUS" SPECIAL INSPECTIONS; CONTINUOUS
INSPECTION IS THE FULL-TIME OBSERVATION OF WORK REQUIRING SPECIAL
INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA
WHERE THE WORK IS BEING PERFORMED; PERIODIC INSPECTION IS THE PART-TIME OR
INTERMITTENT OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN
APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS
BEEN OR IS BEING PERFORMED AND AT THE COMPLETION OF THE WORK. WHERE
"PERIODIC" SPECIAL INSPECTION IS REQUIRED, "PART-TIME" OR "INTERMITTENT" MEANS
THAT INSPECTION OF THE TASK NEEDS TO BE PERFORMED FROM TIME TO TIME DURING
THE PROGRESS OF THE TASK. THE PERIOD OF TIME BETWEEN INSPECTIONS VARIES
GREATLY FOR DIFFERENT TYPES OF WORK DEPENDING ON THE TYPE OF INSPECTION
DONE. THE PERIOD OF TIME BETWEEN INSPECTIONS ALSO DEPENDS ON THE PACE OF
THE CONSTRUCTION, THE NUMBER OF WORKERS, AND THE QUALITY OF THE
WORKMANSHIP, AND OTHER FACTORS. IT IS THE RESPONSIBILITY OF THE SPECIAL
INSPECTOR TO PROVIDE INSPECTIONS AT AN APPROPRIATE FREQUENCY AND AT
APPROPRIATE TIMES DURING CONSTRUCTION. THE INSPECTOR MUST HAVE ADEQUATE
EXPERIENCE AND EXHIBIT GOOD JUDGEMENT IN DETERMINING THE FREQUENCY AND
TIMING OF INSPECTIONS
INSPECTION OF WOOD CONSTRUCTION
NDS 2024
VERIFICATION AND INSPECTION
IDENTIFICATION OF LUMBER GRADE
CONT PERIODIC
- XCOMPETENT INSPECTION OF MATERIALS
AND WORKMANSHIP
INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.
1. INSPECTION OF REINFORCING STEEL,
INCLUDING PLACEMENT.
REQUIRED VERIFICATION AND INSPECTION
OF CONCRETE CONSTRUCTION
VERIFICATION AND INSPECTION
- X
- X
X -
- X
X -
X -
- X
- X
2. INSPECTION OF ANCHORS CAST IN CONCRETE
3. INSPECTION OF ANCHORS POST-
INSTALLED IN HARDENED CONCRETE.
4. VERIFYING USE OF REQUIRED DESIGN MIX.
6. INSPECTION OF CONCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES.
8.
7. INSPECTION FOR MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND TECHNIQUES.
5. PRIOR TO CONCRETE PLACEMENT, FABRICATE
SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP
AND AIR CONTENT TESTS, AND DETERMINE THE
TEMPERATURE OF THE CONCRETE.
CONT PERIODIC
REQUIRED VERIFICATION AND INSPECTION OF SOILS
VERIFICATION AND INSPECTION CONTINUOUS
1. REVIEW CONTRACTOR'S FIELD QUALITY CONTROL PROCEDURES.
VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE
ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER
DEPTH AND HAVE REACHED PROPER MATERIAL.
3. PERFORM CLASSIFICATION AND TESTING OF
COMPACTED FILL MATERIALS.
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESS
DURING PLACEMENT AND COMPACTION OF COMPACTED FILL.
5. PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE
AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY.
PERIODIC
x-x -x-x-x-
LUMBER OR WHERE EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED PER ASTM
INSTALLED ACCORDINGLY. BEFORE USING EQUIVALENT CONNECTORS, SUBMIT LOAD
COMPARISONS WITH CATALOG AND ICBO REPORTS TO THE ARCHITECT/ ENGINEER FOR
REVIEW.ALL NAILING NOT NOTED SHALL BE ACCORDING TO TABLE 2304.9.1 OF THE
INTERNATIONAL BUILDING CODE. ALL CONNECTIONS SHALL HAVE A MINIMUM OF TWO (2)
NAILS, UNLESS NOTED OTHERWISE, AND NAILS SHALL BE A MINIMUM OF 3 IN. LONG AND 0.131
IN. DIAMETER. ALL FASTENERS IN CONTACT WITH PRESSURE PRESERVATIVE TREATED
A-153/A. ALL FASTENERS IN CONTACT WITH FIRE RETARDANT TREATED LUMBER SHALL BE
EDGE OF THE MEMBER. BOLT HOLES 1/32 TO 1/16 INCH LARGER THAN THE BOLT DIAMETER.
ALL NUTS SHALL BE TIGHTENED WHEN INSTALLED AND RE-TIGHTENED AT THE COMPLETION
OF WORK OR BEFORE CLOSING IN. THREAD PROJECTION SHALL BE 1/16 INCH MINIMUM. BOLTS
NAIL DIAMETERS. DISTANCES TO THE EDGE OR END OF THE WOOD SHALL NOT BE LESS THAN
ONE-HALF THE REQUIRED PENETRATION. THE CENTER TO CENTER NAIL SPACING SHALL NOT
BE LESS THAN THE REQUIRED PENETRATION. HOLES FOR NAILS, WHERE NECESSARY TO
PREVENT SPLITTING, SHALL BE SUB-DRILLED TO A DIAMETER NOT MORE THAN 3/4 OF THE NAIL
1.
2.
3.
4.
5.
6.
7.
8.
9.
GRADE STAMPED SOUTHERN PINE NO. 2 (SEE LUMBER GRADES).
FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL DESIGN
SPECIFICATION. ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF A
LUMBER GRADING AGENCY CERTIFIED BY THE AMERICAN LUMBER STANDARDS COMMITTEE.
MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 19%.
DIAMETER.
IN SLOTTED HOLES SHALL BE CENTERED IN THE SLOT UON.
LAG SCREWS: PRE-DRILL WITH A BIT SIZE TO 75% OF THE SHANK DIAMETER FOR THE
THREADED PORTION. LEAD HOLE TO BE THE SAME LENGTH AND DIAMETER AS THE UN-
THREADED SHANK. LUBRICATE LAGS AND SCREW INTO PLACE.
SQUARE STEEL PLATE WASHERS (PW) : ANCHOR BOLTS, BOLTS, LAGS AND NUTS, NOTED PW,
SHALL BE FITTED WITH SQUARE STEEL PLATE WASHERS :
STAINLESS STEEL
BOLT DIA THICKNESS SIZE
(IN) (IN) (IN)
1/2" 3/16" 2x2 5/8" 1/4" 2-1/2x2-1/2 3/4" 5/16" 2-3/4x2-3/4 7/8" 5/16" 3x3 1 3/8" 3-1/2x3-1/2
ROUGH CARPENTRY
NAILS: COMMON WIRE UNLESS OTHERWISE NOTED. PENETRATION SHALL BE EQUAL TO 11
BOLTS: NOT LESS THAN 7 BOLT DIAMETERS FROM THE END AND 4 DIAMETERS FROM THE
FRAMING CONNECTORS: SIMPSON STRONG-TIE, CATALOG C-2025. ICBO APPROVED AND
10.
GALVANIZING: ALL EXPOSED STEEL TIMBER HARDWARE AND CONNECTORS.
PRESERVATIVE TREATED WOOD: ALL EXPOSED WOOD MEMBERS
CUT STEEL WASHERS : BOLTS , LAGS AND NUTS FITTED WITH CUT STEEL WASHERS UON
- X
CONTINUOUS WALL
OR PAD FOUNDATION
(N) STEEL COLUMN
F 2.0
(-1'-4") FOOTING TAG
SHEAR WALL
FOOTING STEP
CMU WALL
CONCRETE WALL
HEADERH-X
MOMENT CONNECTION
CANTILEAVER CONNECTION
STEP IN SLAB
DECK SPAN DIRECTION
S
SYMBOLS
WOOD/STEEL WALL
GIRDER
(E) STEEL COLUMN
JOIST
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
L
LU
KE
S-101
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
ST
RU
CT
UR
AL
FO
UN
DA
TI
ON
P
LA
N
06 11
GENERAL NOTES
KEYNOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
2. PROVIDE SHORING AS REQUIRED TO SUPPORT ROOF STRUCTURE DURING
COLUMN REPLACEMENT.
REPLACE EXISTING WOOD 5X5 COLUMNS (F.V.) WITH NEW 6X6 WOOD
COLUMN. WOOD SHALL BE TREATED SOUTHERN PINE NO. 2. REFER 1&3/S-501
FOR BASE AND CAP DETAILS.
REPLACE EXISTING 2X6 WOOD DIAGONAL WALL BRACES. WOOD SHALL BE
TREATED SOUTHERN PINE NO. 2.REFER 2/S-501 FOR CONNECTION DETAIL.
REMOVE AND REPLACE EXISTING METAL SIDING AS REQUIRED FOR COLUMN
REPLACEMENT. REPLACE EXISTING 2X6 WOOD GIRTS. WOOD SHALL BE
TREATED SOUTHERN PINE NO. 2. TYP. FOR NORTH WALL AND FIRST BAY ON
WEST RETURN WALL. REFER 4/S-501 FOR CONNECTION DETAIL.
REMOVE EXISTING WOOD COLUMN FOOTING AS REQUIRED TO INSTALL NEW
24"X24"X4'-0" FOOTING FOR NEW 6X6 COLUMNS. REFER 1/S-501
S-101
STRUCTURAL FOUNDATION PLAN
SCALE: 1/16" = 1'-0"
EXISTING WOOD COLUMN TO REMAIN, TYP.
EXISTING ASPHALT OVER CONCRETE
EXISTING METAL SIDING
ON WOOD GIRTS TO REMAIN., TYP 2
S-501
S-501
S-501
4TYP.
TYP.
S-501
S-501
S-501
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text
340'-0" FIELD VERIFY
AutoCAD SHX Text
50'-0" FIELD VERIFY
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
L
LU
KE
S-102
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
ST
RU
CT
UR
AL
R
OO
F
FR
AM
IN
G
PL
AN
07 11
GENERAL NOTES
KEYNOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
2. PROVIDE SHORING AS REQUIRED TO SUPPORT ROOF STRUCTURE DURING
COLUMN REPLACEMENT.
REPLACE EXISTING WOOD 5X5 COLUMNS (F.V.) WITH NEW 6X6 WOOD
COLUMN. WOOD SHALL BE TREATED SOUTHERN PINE NO. 2. REFER 1&3/S5-01
FOR BASE AND CAP DETAILS.
REPLACE EXISTING 2X6 WOOD DIAGONAL WALL BRACES. WOOD SHALL BE
TREATED SOUTHERN PINE NO. 2.REFER 2/S-501 FOR CONNECTION DETAIL.
REMOVE AND REPLACE EXISTING METAL SIDING AS REQUIRED FOR COLUMN
REPLACEMENT. REPLACE EXISTING 2X6 WOOD GIRTS. WOOD SHALL BE
TREATED SOUTHERN PINE NO. 2. TYP. FOR NORTH WALL AND FIRST BAY ON
WEST RETURN WALL. REFER 4/S-501 FOR CONNECTION DETAIL.
DAMAGED WOOD TRUSS 2X4 BOTTOM CHORD. NEW WOOD SHALL BE
TREATED SOUTHERN PINE NO. 2. REFER 5/S-501 FOR REPAIR DETAIL.
S-102
STRUCTURAL ROOF FRAMING PLAN
SCALE: 1/16" = 1'-0"
EXISTING WOOD COLUMN TO REMAIN, TYP.
EXISTING WOOD TRUSSES AT 4'-0" O.C.
EXISTING METAL SIDING
ON WOOD GIRTS TO REMAIN, TYP.
S-501
S-501
EXISTING METAL ROOF PANEL ON WOOD TRUSSES
TO REMAIN.
RIDGE
EXISTING (2) 2X10 BEAMS AT TRUSS BEARING
TO REMAIN, TYP.
S-501
S-501
TYP.
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
L
LU
KE
S-501
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
DE
TA
ILS
08 11
COL. BASE DETAIL1
S-501 1-1/2"=1'-0"
REPLACE 5X5 WOOD COL W/ 6X6
TREATED SOUTHERN PINE NO. 2.
SIMPSON STRONGTIE MPB66Z
W/ (24) 1/4" X 2-1/2" SDS SCREWS
OR APPROVED EQUALS.
EXISTING 2" ASPHALT OVER 8"
CONC. SLAB OR FOOTING.(FIELD VERIFY)
NEW 24"X24"X4'-0" CONC. FOOTING W/
(4) #4 VERTS AND #3 TIES AT 3" FOR 1'-0"
THEN 12" OC
COL. TO BRACE DETAIL2
S-501 1-1/2" = 1'-0"
REPLACE 5X5 WOOD COL W/ 6X6
TREATED SOUTHERN PINE NO. 2.
REPLACE 2X6 W/ TREATED SOUTHERN PINE NO. 2.
POSITION TO AVOID INTERFERENCE W/ COL. BASE CONNX AND
COL. CAP CONNX.
SIMPSON STRONGTIE ML24Z CLIP W/
(6) 1/4"ØX2-1/2" SDS SCREWS. TYP TOP AND
BOTTOM OF BRACES OR APPROVED EQUALS.
REFER
1/S-501
COL. CAP DETAIL3
S-501 1-1/2" = 1'-0"
EXISTING WOOD BLOCKING/COL TOP
BETWEEN BEAMS TO REMAIN
NOTE: TRUSSES NOT SHOWN FOR
CLARITY.
EXISTING (2) 2X10 WOOD BEAMS TO REMAIN
REFER ARCH. FOR SIDING
SIMPSON STRONGTIE CCQ86SDS2.5
W/ (16) 14"ØX2 12" SDS SCREWS INTO BEAM
AND (14) INTO COLUMN, OR APPROVED EQUALS.
REPLACE 5X5 COL W/ 6X6
TREATED SOUTHERN PINE NO. 2.
GIRT TO COL. DETAIL4
S-501 1-1/2"= 1'-0"
REPLACE 2X6 WALL GIRT W/ TREATED
SOUTHERN PINE NO. 2.
NEW 6X6 WOOD COLUMN
SIMPSON STRONGTIE ML24Z CLIP W/ (6)
1/4"ØX2-1/2" SDS SCREWS, TYP. TOP AND
BOTTOM OF BRACES AND EA. END OF
GIRTS OR APPROVED EQUALS
WOOD TRUSS REPAIR DETAIL5
S-501 1-1/2" = 1'-0"
2'-0" 2'-0"
AA
SECTION-AA
WOOD TRUSS WEB MEMBERS W/ PRESS PLATE.
WOOD TRUSS BOTTOM CHORD 2"X4"
EXTENTS OF BOTTOM CHORD DAMAGE F.V.
SANDWICH BOTTOM CHORD W/ (2) 2X4 ATTACH
W/ (24) .162Ø X 3-1/2" NAILS EA. END (12) EA FACE.
F.V.
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
T D
EL
AN
EY
AD-101
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
AR
CH
IT
EC
TU
RA
L
DE
MO
LIT
IO
N
PL
AN
PA
RT
IA
L P
LA
N
09 11
GENERAL NOTES
KEYNOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
METAL WALL PANEL - REMOVE METAL WALL PANEL ON NORTH END WALL AND
1ST/ NW BAY ON WEST SIDE.
WOOD FRAMING - REMOVE WOOD 5X5 POSTS AT END WALL, 2x WALL GIRTS, EXISTING WOOD SECURED TO METAL PANEL, AND DECAYED WOOD ALONG
NORTH WALL AND NW BAY ON WEST SIDE. REFER STRUCTURAL.
OPEN BAY EAST SIDE - REMOVE WOOD 5X5 POSTS AT OPEN EAST SIDE.
REFER STRUCTURAL.
FLOOR - REMOVE ASPHALT TOPPING AT FIRST NORTH BAY AND BELOW
NORTH END WALL, TO CONCRETE SLAB BELOW. REFER CIVIL FOR EXTERIOR
ASPHALT PAVING NEW WORK.
AD-101
ARCHITECTURAL DEMOLITION PLAN
SCALE: 1/16" = 1'-0"
AD-101
ARCHITECTURAL DEMOLITION PARTIAL PLAN
SCALE: 1/4" = 1'-0"
2'-0"
2'- 0"
.3
2'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
340'-0" FIELD VERIFY
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
T D
EL
AN
EY
A-101
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
AR
CH
IT
EC
TU
RA
L N
EW
W
OR
K
PL
AN
PA
RT
IA
L P
LA
N
10 11
GENERAL NOTES
KEYNOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
METAL WALL PANEL - PROVIDE NEW METAL WALL PANEL ON NORTH END
WALL AND 1ST/ NW BAY ON WEST SIDE. MATCH EXISTING PANEL PROFILE.
NOTE: DESIGN BASED ON THE METAL STORE OK, MS-SNAP, 24 GAUGE,
16-INCH WIDTH, COLOR: REGAL WHITE, KYNAR FINISH. TRIM TO INCLUDE:
CORNER TRIM, METAL DRIP, FASCIA, OVERHEAD DOOR DRIP, ETC.
METAL WALL PANEL, EXISTING TO REMAIN (COLOR: WHITE)
WOOD FRAMING - PROVIDE NEW WOOD CORNER COLUMNS AT POSTS AT
NORTH END WALL, WOOD BAY POSTS, 2x WOOD WALL GIRTS, AND 2x WOOD
BRACING ALONG NORTH END WALL AND NW BAY ON WEST SIDE. REFER
STRUCTURAL.
OPEN EAST SIDE - PROVIDE NEW WOOD BAY POSTS AT OPEN EAST SIDE.
PAINT: SW 4084, SAFETY YELLOW. REFER STRUCTURAL.
FLOOR - TAPER ASPHALT TOPPING FROM NORTH END WALL TO FIRST BAY
POST WITH GRADULE SLOPE TO REMAINING ASPHALT TOPPING. REFER CIVIL
FOR EXTERIOR ASPHALT PAVING NEW WORK.
PAINT - SAND, PRIME, PAINT TWO COATS AT NEW WORK WOOD COLUMNS
AND EXPOSED NEW WORK WOOD MEMBERS AT NORTH END WALL. SELECT
AND APPLY PAINT WITH SHEENS (GLOSS LEVELS) APPROPRIATE FOR THE
APPLICATION FOLLOWING UFGS SECTION 09 96 00 HIGH PERFORMANCE
COATINGS 11/14. PROVIDE SAFETY MARKINGS ON WALLS/FLOORS IN
ACCORDANCE WITH TITLE 29 CFR 1910.22 & 144(A)(3). COLOR WOOD POST:
SW 4084, SAFETY YELLOW. COLOR: NEW WOOD MEMBERS - SW 7006, EXTRA
WHITE.
VENT - PROVIDE AN INTERIOR VENTED OPENING AT BASE OF METAL WALL
PANEL WITH 2x WOOD FRAMING AT HEAD. SECURE TO ADJACENT WOOD
POSTS. REFER STRUCTURAL. NOTE: VENTED OPENING SIZING TO ALLOW
WATER TO DRAIN QUICKLY DURING RAIN EVENTS.
A-101
ARCHITECTURAL NEW WORK PLAN
SCALE: 1/16" = 1'-0"
A-101
ARCHITECTURAL NEW WORK PARTIAL PLAN
SCALE: 1/4" = 1'-0"
10'-0"+/- 10'-0"+/-
10'-0"+/- 10'-0"+/-
10'-0"+/-
10'-0"+/-
50'-0" FIELD VERIFY
10'-0"+/-10'-0"+/-10'-0"+/-
B
AA-201
A-201
1 A-201
10'-0"+/- 10'-0"+/-
10'-0"+/- 10'-0"+/-
10'-0"+/-
10'-0"+/-
340'-0" FIELD VERIFY
50'-0" FIELD VERIFY
10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/- 10'-0"+/-
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
NK
ER
A
IR
F
OR
CE
B
AS
E, O
KL
AH
OM
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
RE
PA
IR
S
TR
UC
TU
RA
L I
NT
EG
RI
TY
B1
4, PO
ST
N
OR
TH
W
AL
L
XX
X TE
PA
-S
R M
T D
EL
AN
EY
A-201
F
BA
KE
R
S
SW
IF
T
\E ng r\D es ig n\ s\
\2
4\
0_ Su pp or t\0 _3
_D ra w in gs
EX
TE
RI
OR
IN
TE
RI
OR
EL
EV
AT
IO
NS
11 11
GENERAL NOTES
KEYNOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
METAL WALL PANEL, NEW WORK - MATCH REMAINING ADJACENT METAL
WALL PANEL.
METAL WALL PANEL, EXISTING TO REMAIN
METAL ROOF PANEL, EXISTING TO REMAIN. PROVIDE NEW FLASHING, DRIP
EDGE, ETC AT NORTH END AND EAST OPEN BAYS.
WOOD FRAMING, NEW WORK - WOOD CORNER COLUMNS AND POSTS AT
NORTH END WALL. PAINT: SW 4084, SAFETY YELLOW. REFER STRUCTURAL.
WOOD FRAMING, NEW WORK - WOOD BAY POSTS. PAINT: SW 4084, SAFETY
YELLOW. REFER STRUCTURAL.
WOOD FRAMING, NEW WORK - 2x WOOD WALL GIRTS, PAINT. COLOR: NEW
WOOD MEMBERS - SW 7006, EXTRA WHITE.REFER STRUCTURAL.
WOOD FRAMING, EXISTING TO REMAIN - 2x WOOD WALL GIRTS & POSTS AT
WEST AND SOUTH WALL.
WOOD FRAMING, NEW WORK - 2x WOOD BRACING, PAINT. COLOR: NEW
WOOD MEMBERS - SW 7006, EXTRA WHITE.REFER STRUCTURAL.
FLOOR - TAPER ASPHALT TOPPING FROM NORTH END WALL TO FIRST BAY
POST WITH GRADUAL SLOPE TO REMAINING ASPHALT TOPPING. REFER CIVIL
FOR EXTERIOR ASPHALT PAVING NEW WORK.
VENT - REFER SHEET A-101 AND STRUCTURAL.
B A-201
INTERIOR ELEVATION - PARTIAL
SCALE: 1/4" = 1'-0"
A-201
WEST ELEVATION - EXTERIOR - PARTIAL
SCALE: 1/4" = 1'-0"
A A-201
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
A-201
NORTH ELEVATION - EXTERIOR
SCALE: 1/4" = 1'-0"
11 1
. 1
11 11 11 11 11
50'-0" +/-…