A005_DID_DI_QCIC_80798C_FD20301602832_01.pdf

Data Item Description Rev. C PDF 48 KB Posted

Attached to
B-2 Overhaul Program of the Receiver, Counter Measure Units
Solicitation number
FA8119-18-R-0031
Issued by

About this file

DID DI-QCIC-80798C

View the file

Other versions and copies of DI-QCIC-80798C

File Revision Posted Attached to
C07_DI-QCIC-80798C Calibration Certif.pdf Rev. C NSWCCD Emergency repairs, corrective maintenance, preventive maintenance (PM) of TA Instruments equipment
DiD-DI-QCIC-80798C.pdf Rev. C Repair of B-2 Transponder Set (KU Band)
DI-QCIC-80798C_CalRpt.pdf Rev. C Length Bar Interferometry System and a Gage Block Interferometry System
DI-QCIC-80798C_CalRpt.pdf Rev. C Magnification Check Kits
DI-QCIC-80798C_CalRpt.pdf Rev. C Magnification Check Kits
7_DID DI-QCIC-80798C.pdf Rev. C Piston Prover Liquid Flow Calibrator CFP400
7. DI-QCIC-80798C.pdf Rev. C Russell Optical Reference Flats
Attachment 6 - DI-QCIC-80798C.pdf Rev. C Naval Surface Warfare Center Carderock Divisions Equipment Maintenance Blanket Purchase Agreement
7. DID - DI-QCIC-80798C.pdf Rev. C Ceramic Gage Blocks
DI-QCIC-80798C.pdf Rev. C Remanufacture of the B-2 Flight Control Actuators
7_DID_DI-QCIC-80798C.pdf Rev. C Mitutoyo Calibration Services
DI-QCIC-80798C_CalRpt.pdf Rev. C Particle Count Verification Fluid
DI-QCIC-80798C_CalRpt.pdf Rev. C Primary Vibration Calibration System
7_DID_DI-QCIC-80798C.pdf Rev. C ISO-17025:2017 ACCREDITATION
DI-QCIC-80798C.pdf Rev. C Remanufacture of Air Launched Cruise Missile (ALCM) Air Cycle Machine (ACM)
DI-QCIC-80798C.pdf Rev. C NAVAIR METCAL Keysight
DI-QCIC-80798C.pdf Rev. C Pegasus Calibration System
9c DI-QCIC-80798C.pdf Rev. C FARO PCMM (SCANARM)
7_DI-QCIC-80798B_CalRpt.pdf Rev. B Fluke Calibration Items
DI-QCIC-80798B_CalRpt.pdf Rev. B Starret Cage Block
Show all 20

Who attaches DI-QCIC-80798C

Other files

File Type Posted
FA811918R0031_______0001.pdf PDF
GFP_FD20301602832_03.pdf PDF
PWS_REV_7FEB19_FD20301602832_03.docx DOCX document
PWS_FD20301602832_01.docx DOCX document
FA811918R0031.pdf PDF
CDRL_FD20301602832_01.pdf PDF
A006_DID_DI_SESS_80639D_FD20301602832_01.pdf PDF
A014_DID_DI_MISC_81832_FD20301602832_01.pdf PDF
A002_DID_DI_PSSS_81995_FD20301602832_01.pdf PDF
IUID_FD20301602832_01_0001.pdf PDF
GFP_FD20301602832_01.pdf PDF
ITMDESC_FD20301602832_01_0001.pdf PDF
ITMDESC_FD20301602832_01_0007.pdf PDF
A0010_DID_DI_MGMT_80501_FD20301602832_01.pdf PDF
IUID_FD20301602832_01_0009.pdf PDF
IUID_FD20301602832_01_0011.pdf PDF
A007_DID_DI_MISC_80711A_FD20301602382_01.pdf PDF
ITMDESC_FD20301602832_01_0005.pdf PDF
PWS_CAVAF_GFM_FD20301602832_01.docx DOCX document
IUID_FD20301602832_01_0003.pdf PDF
A013_DID_DI_ADMN_81250B_FD20301602832_01.pdf PDF
A003_DID_DI_MGMT_82128_FD20301602832_01.pdf PDF
A004_DID_DI_MGMT_80441C_FD20301602832_01.pdf PDF
ITMDESC_FD20301602832_01_0003.pdf PDF
A009_DID_DI_MGMT_80368A_FD20301602832_01.pdf PDF
IUID_FD20301602832_01_0007.pdf PDF
A012_DID_DI_ADMN_81373_FD20301602832_01.pdf PDF
A001_DID_DI_MGMT_81634C_FD20301602832_01.pdf PDF
A011_DID_DI_ADMN_81249B_FD20301602832_01.pdf PDF
TRNSPDATA_FD20301602832_01.pdf PDF
ITMDESC_FD20301602832_01_0011.pdf PDF
ITMDESC_FD20301602832_01_0009.pdf PDF
A008_DID_DI_PSSS_81656B_FD20301602832_01.pdf PDF
PKGRQMT_FD20301602832_01.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DATA ITEM DESCRIPTION

Title: CALIBRATION CERTIFICATE/REPORT

Number: DI-QCIC-80798C Approved Date: 20170123 AMSC Number: F9766 Limitation: N/A DTIC Applicable: No GIDEP Applicable: No Preparing Activity: 36 Project Number: QCIC-2017-003 Applicable Forms: N/A Use/Relationship: The Calibration Certificate/Report documents calibration certificates or reports accompanying the calibrations performed on Department of Defense (DoD) test, measurement, and diagnostic equipment.

a. This Data Item Description (DID) contains the format and content preparation instructions for the data product generated by the specific and discrete task requirement as delineated in the contract.

b. This DID is applicable to contracts requiring calibration of test equipment prior to delivery.

This DID is consistent with ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories, requirements for calibration reports or certificates.

(Copies of this document are available online at http://www.iso.org.)

c. This DID supersedes DI-QCIC-80798B.

Requirements:

1. Reference documents. The applicable issue of the documents cited herein, including their approval dates and dates of any applicable amendments, notices, and revisions, shall be as specified in the contract.

2. Format. Contractor format is acceptable.

3. Content. The calibration certificate or report shall include:

a. Title (e.g., calibration certificate or calibration report);

b. The name and address of the laboratory and the location where the calibrations were carried out, if different from the address of the laboratory;

c. Unique identification of the calibration certificate or test report (such as the serial number), and on each page an identification in order to ensure that the page is recognized as a part of the test report or calibration certificate, and a clear identification of the end of the calibration certificate or test report;

d. The name and address of the client or customer;

e. Identification of the method used;

f. A description of, the condition of, and the unambiguous identification of the item(s) tested or calibrated;

g. The date of receipt of the test or calibration item(s) where this is critical to the validity and application of the results, and the date(s) of performance of the test or calibration;

DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.

Source: https://assist.dla.mil -- Downloaded: 2017-03-13T13:39Z Check the source to verify that this is the current version before use.

DI-QCIC-80798C

h. Reference to the sampling plan and procedures used by the laboratory or other bodies where these are relevant to the validity or application of the results;

i. The test or calibration results with, where appropriate, the units of measurement;

j. The name(s), function(s) and signature(s) or equivalent identification of person(s) authorizing the calibration certificate or test report;

k. Where relevant, a statement to the effect that the results relate only to the items tested or calibrated;

l. The conditions (e.g., environmental) under which the calibrations were made that have an influence on the measurement results;

m. The uncertainty of measurement or a statement of compliance with an identified metrological specification or clauses thereof;

n. Evidence that the measurements are traceable.

End of DI-QCIC-80798C.