This document contains an amendment to drawings and specifications for a federal contract solicitation to repair a community activity center building. The amendment revises the contractor laydown area and ceiling specifications. It also updates experience requirements to include one year of J2 innovations controls integration experience plus two years of experience integrating a Niagara-based system. The related solicitation is to provide all services necessary to repair Community Activity Center Building 807 at Minneapolis Air Reserve Station for $39.5 million or less. The 100% small business set-aside is a firm fixed price contract requiring registration in SAM and a bid guarantee. The proposal acceptance period ends 30 September 2022 for the Air Force project.
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 13 Amendement-1 CAC Repair Project QJKL-18-0024 13 May 2022
CHANGE #1 – Revision to Laydown Area (drawing G-008).
FROM: Contractor Laydown Area “A” with Alternate Area “B”
TO: Alternate Laydown Area “B” AND Additional Laydown area along Apollo Ave.
CHANGE #2 - Revision to drawings AD101, AD102, AD103, and AD401 Note D10
FROM: Ceiling Tile and Grid to be removed as require for installation of fire suppression system. Salvage existing ceiling tile and grid for reuse in same location.
CHANGED TO READ: Ceiling Tile and Grid to be removed for installation of fire suppression system.
CHANGE #3 - Revisions to Attachment 8, Section L, Volume III: Written Proposal, 1. Format and Specific Content: Subfactor 1
FROM: Subfactor 1: Qualifications and prior experience identifying at least three (3) years’ experience of related work: retrofit projects and specifically Monaco fire alarm & mass notification, and J2 Innovations Fin Stack direct digital controls.
Provide valid training documentation for at least one expected Monaco installer and documented J2 Innovations Fin Stack software integration with an existing central control system.
TO: Subfactor 1: Qualifications and prior experience identifying at least three (3) years’ experience of related work: retrofit projects and specifically Monaco fire alarm & mass notification, and J2 Innovations Fin Stack direct digital controls OR 1 years’ experience of related work of J2 innovations Fin Stack direct digital controls plus 2 years of integration from an existing Niagara based central control system to another DDC controls product. Provide valid training documentation for at least one expected Monaco installer and documented J2 Innovations Fin Stack software integration with an existing central control system.