Attachment_11_ASHE_18-1025_Drawings_(Seed_project)_Part18.pdf
PDF 327 KB Posted
- Attached to
- Multiple Award Construction Contract (MACC) Italy Federal contract opportunity
- Solicitation number
- FA568219RA001
About this file
This notice is a draft request for proposal for an indefinite delivery indefinite quantity multiple award construction contract for design-build construction services in Italy. The scope of work includes projects such as grading, water and sewer lines, painting, roofing, building renovation, new construction, electrical work, HVAC, fire suppression systems, fuel systems, generators and communications systems. The minimum contract value is $2,500 and maximum is $96 million across all awards. The minimum task order is $2,500 and maximum is $7 million. The contract will have a one-year base and four option years. Comments on the draft attachments are due by April 19, 2019. The solicitation will be issued through beta.SAM.gov and no paper copies will be distributed. The place of performance will primarily be Aviano Air Base, Italy but could include other locations in the Republic of Italy.
Attachment 11 ASHE 18-1025 Drawings (Seed Project) Part 18
View the file
Other files for this federal contract opportunity
Show all 50
Multiple Award Construction Contract (MACC) Italy has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
GDCP
SYSTEM OUTPUTS
ALARM INPUTS
SUPERVISORY SIGNAL INPUTS
TROUBLE SIGNAL INPUTS
SYSTEM OUTPUTS
ALARM INPUTS
st
C
IV
IL
E
N G
IN
E
E R
IN
G
S Q
U A
D R
O N st
C E
S /C
E N
M P
R O
JE
C
T M
A N
A G
E M
E N
T E
LE
M
E N
T st
F
IG
H
TE
R W
IN
G
100%
Engineering Tools Srl
Via del Makò n. 33
33084 Cordenons (PN)
TEL.: +39 0434 536333
FAX: +39 0434 542813
E-mail: info@engtools.eu
PEC: info@pec.engtools.eu
FA602
B1
IMPIANTO DI RIVELAZIONE ED ALLARME GAS METANO
B3
IMPIANTO DI RIVELAZIONE ED ALLARME INCENDIO: MATRICE DELLE OPERAZIONI
FIRE DETECTION AND ALARM SYSTEM: MATRIX OF OPERATIONSGAS METHANE DETECTION AND ALARM SYSTEM
C1
IMPIANTO DI RIVELAZIONE ED ALLARME GAS METANO:
MATRIX OF THE OPERATIONS
GAS METHANE DETECTION AND ALARM SYSTEM:
MATRICE DELLE OPERAZIONI
AutoCAD SHX Text 60 cd
AutoCAD SHX Text
WP
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS DETECTION
AutoCAD SHX Text
CONTROL PANEL
AutoCAD SHX Text
GAS METANO
AutoCAD SHX Text
BACKUP BATTERY
AutoCAD SHX Text
BATTERIE
AutoCAD SHX Text
CENTRALE RIVELAZIONE
AutoCAD SHX Text Class = II
AutoCAD SHX Text Un=230/400V
AutoCAD SHX Text Uc=335V
AutoCAD SHX Text Iimp(10/350)=3kA
AutoCAD SHX Text In(8/20)=20kA
AutoCAD SHX Text Imax(8/20)=40kA
AutoCAD SHX Text Up(20kA)=1,55kA
AutoCAD SHX Text
SPD
AutoCAD SHX Text PRIMARY POWER LINE 230Vac
AutoCAD SHX Text
ROOM 12
AutoCAD SHX Text
BOILER ROOM
AutoCAD SHX Text
CIRCUIT FAULT
AutoCAD SHX Text
SPRINKLER CONTROL VALVE TAMPER SWITCH
AutoCAD SHX Text
DETECTOR (SMOKE, HEAT)
AutoCAD SHX Text
MANUAL STATION
AutoCAD SHX Text
WATER FLOW SWITCH
AutoCAD SHX Text
LOW / MISSING BATTERY
AutoCAD SHX Text
SUPERVISED COMPONENT FAILURE
AutoCAD SHX Text
MONITORING STATION CONNECTION FAULT
AutoCAD SHX Text
AC POWER FAILURE
AutoCAD SHX Text
DUCT HEAT DETECTOR 70°C
AutoCAD SHX Text
ALARM RECEIPT
AutoCAD SHX Text
AT FACP + AT
AutoCAD SHX Text
REMOTE CONTROL
AutoCAD SHX Text
TROUBLE SIGNAL
AutoCAD SHX Text
AT FACP +
AutoCAD SHX Text
REMOTE CONTROL
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
SUPERVISORY
AutoCAD SHX Text
SIGNAL AT FACP +
AutoCAD SHX Text
REMOTE CONTROL
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
TRANSMIT
AutoCAD SHX Text
ALARM TO
AutoCAD SHX Text
BASE FIRE
AutoCAD SHX Text
DEPARTMENT
AutoCAD SHX Text
TRANSMIT
AutoCAD SHX Text
TROUBLE SIGNAL
AutoCAD SHX Text
TO FIRE
AutoCAD SHX Text
DEPARTMENT
AutoCAD SHX Text
TRANSMIT
AutoCAD SHX Text
SUPERVISORY
AutoCAD SHX Text
SIGNAL TO FIRE
AutoCAD SHX Text
DEPARTMENT
AutoCAD SHX Text
ACTIVATE FIRE
AutoCAD SHX Text
ALARM VISUAL
AutoCAD SHX Text
AND AUDIBLE
AutoCAD SHX Text
APPLIANCES
AutoCAD SHX Text
DEACTIVATE FIRE
AutoCAD SHX Text
ALARM VISUAL
AutoCAD SHX Text
AND AUDIBLE
AutoCAD SHX Text
APPLIANCES
AutoCAD SHX Text
AM
AutoCAD SHX Text M
AutoCAD SHX Text
TO THE FACP
AutoCAD SHX Text
ALLA CENTRALE
AutoCAD SHX Text
ALLARME INCENDIO
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
GAS DETECTOR
AutoCAD SHX Text
ALARM RECEIPT
AutoCAD SHX Text
AT GAS DETECTION
AutoCAD SHX Text
CONTROL PANEL
AutoCAD SHX Text
GDCP
AutoCAD SHX Text
TRANSMIT
AutoCAD SHX Text
SUPERVISORY AT
AutoCAD SHX Text
FIRE ALARM
AutoCAD SHX Text
CONTROL PANEL
AutoCAD SHX Text
ACTIVATE
AutoCAD SHX Text
GAS DETECTION
AutoCAD SHX Text
VISUAL AND
AutoCAD SHX Text
AUDIBLE ALARM
AutoCAD SHX Text
APPLIANCES
AutoCAD SHX Text
OPEN THE
AutoCAD SHX Text
ELECTROVALVE
AutoCAD SHX Text
TO STOP THE
AutoCAD SHX Text
GAS SUPPLY
AutoCAD SHX Text NOTE ABOUT SLEEPING AREA: UPON DETECTION OF SMOKE, AN AUDIBLE SIGNAL MUST ACTIVATED IN ALL SLEEPING ROOMS AND THE SHARED/COMMON SPACES WITHIN THE "DWELLING" UNIT, AND A DISTINCT SLEEPING ROOM SMOKE DETECTOR SIGNAL SHALL BE SENT TO THE FACP. SINCE THERE IS ONLY ONE SLEEPING AREA IN THIS FACILITY, THE FIRE ALARM FROM THE SLEEPING ROOM CAN ACTIVATE THE WHOLE FACILITY NOTIFICATION APPLIANCES. NOTA IN MERITO ALL'AREA DI RIPOSO: ALLA RILEVAZIONE DI FUMO, UN SEGNALE ACUSTICO DEV'ESSERE ATTIVATO IN TUTTE LE STANZE DA LETTO ED I LOCALI COMUNI COMPRESI NELL'AREA DI RIPOSO, ED UN SEGNALE DISTINTO DI ALLARME FUMO DALLA CAMERA DEV'ESSERE INVIATO ALLA CENTRALE DI RILEVAZIONE ED ALLARME. POICHE' NELL'EDIFICIO E' PRESENTE UN'UNICA AREA DI RIPOSO, UN ALLARME PROVENIENTE DA ESSA POTRA' ATTIVARE I DISPOSITIVI D'ALLARME DI TUTTO L'EDIFICIO.
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SIZE: A1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
PROJECT NUMBER: ASHE 18-1025
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWER:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
DRAFTMAN:
AutoCAD SHX Text
SUBMITTAL
AutoCAD SHX Text
AVIANO AIR BASE
AutoCAD SHX Text
AVIANO, ITALY
AutoCAD SHX Text
FAC.939, AREA F, AVIANO AB, ITALY
AutoCAD SHX Text
RENOVATE/EXPAND FAC.939 FOR EOD
AutoCAD SHX Text
FABBR.939, AREA F, AVIANO AB, ITALIA
AutoCAD SHX Text
RISTRUTTURAZIONE ED AMPLIAMENTO FABBR.939 PER EOD
AutoCAD SHX Text
FEBRUARY 2019
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
FIRE ALARM AND GAS DETECTION SYSTEMS: OPERATIONS
AutoCAD SHX Text
IMPIANTI ALLARME INCENDIO E RIVELAZIONE GAS: OPERAZIONI
AutoCAD SHX Text
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
| 105_B939-E-001-100%.pdf |
| 154_B939-FA602-100%.pdf |
| Fogli e viste |
| FA602 |
File details come from the government source that posted it. Updated .