RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_5.pdf

PDF 2 MB Posted

Attached to
Multiple Award Construction Contract (MACC), Ramstein AB, Germany Federal contract opportunity
Solicitation number
FA5613-14-R-0016
Issued by
Department of the Air Force Materiel Command Installation and Mission Support Center Installation Contracting Agency

About this file

RFP Atch 1 Annex 30e AF Comm Standards Part 5

View the file

Other files for this federal contract opportunity

Other files attached to Multiple Award Construction Contract (MACC), Ramstein AB, Germany, newest first.
File Type Posted
FA5613-14-R-0016-0003-Seed_Project_SOW-26Nov14.pdf PDF
FA5613-14-R-0016-0003.pdf PDF
Q A_Set__4.pdf PDF
FA5613-14-R-0016-0002-Seed_Project_SOW-13Nov14.pdf PDF
FA5613-14-R-0016-0002.pdf PDF
Questions_and_Answers_Set__3.pdf PDF
Questions_and_Answers_Set_2.pdf PDF
Questions_and_Answers_Set_2.pdf PDF
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg12.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg11.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg10.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg7.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg6.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg5.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg4.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg3.DWG DWG drawing
FA5613-14-R-0016-0001.pdf PDF
Pre-proposal_Conference_Slides_and_Site_Visit.pdf PDF
RFP_14-R-0016-Atch2a-Seed_Project_Floor_Plan_pg2.dwg DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Floor_Plan_pg1.dwg DWG drawing
Q A_Set__1-20Oct2014.doc DOC document
RFP_14-R-0016-Atch1-Annex30h._AF_3064 _Progress_Schedule.pdf PDF
RFP_14-R-0016-Atch1-Annex30f._USAFE_79 _Base_Entry.pdf PDF
RFP_14-R-0016-Atch1-Annex30i._AF_3065 _Progress_Report.pdf PDF
RFP_14-R-0016-Atch1-Annex30j._AF_3000 _Material_Approval.pdf PDF
RFP_14-R-0016-Atch1-Annex30c._Spangdahlem_ACG_Section_III_7-8.pdf PDF
RFP_14-R-0016-Atch1-Annex30c._Spangdahlem_ACG_Section_II.pdf PDF
RFP_14-R-0016-Atch1-Annex30i._AF_3065 _Progress_Report.xfdl XFDL file
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_6.pdf PDF
RFP_14-R-0016-Atch1-Annex30h._AF_3064 _Progress_Schedule.xfdl XFDL file
RFP_14-R-0016-Atch1-Annex30g._Blank_STP_Format.docx DOCX document
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_7.pdf PDF
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_4.pdf PDF
RFP_14-R-0016-Atch1-Annex30k._700_CONS_Form_66 _Matl_Submittals.doc DOC document
RFP_14-R-0016-Atch1-Annex30f._USAFE_79 _Base_Entry.xfdl XFDL file
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_1.pdf PDF
RFP_14-R-0016-Atch1-Annex30j._AF_3000 _Material_Approval.xfdl XFDL file
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_3.pdf PDF
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_2.pdf PDF
RFP_14-R-0016-Atch1-Annex30c._Spangdahlem_ACG_Section_I.pdf PDF
RFP_FA5613-14-R-0016.doc DOC document
RFP_14-R-0016-Atch4-SubK_Consent.doc DOC document
RFP_14-R-0016-Atch2b-Seed_Project_UFC_Band_Trng_Facilities.pdf PDF
RFP_14-R-0016-Atch1-Annex30b._Ramstein-KMC_ACS_Edition_2008.pdf PDF
RFP_14-R-0016-Atch5-PPQ.doc DOC document
Cover-Ltr-RFP-MACC.pdf PDF
RFP_14-R-0016-Atch1-Annex30a._KMC-Spang_Base_Appearance.doc DOC document
RFP_14-R-0016-Atch2a-Seed_Project_Map Floor_Plan Drawings.pdf PDF
RFP_14-R-0016-Atch3-PPID.doc DOC document
RFP_14-R-0016-Atch1-General_Req-21Aug14.doc DOC document
Show all 50

Multiple Award Construction Contract (MACC), Ramstein AB, Germany has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Outside Plant Cable and Wire

A Solid Connection

The name SUPERIOR ESSEX is practically synonymous with outside plant (OSP) cable and wire. With a heritage of more than 40 years as a telecommunications cable manu-facturer, SUPERIOR ESSEX has grown to become the largest in North America†. Our market position was built from an endless pursuit of perfection — in our products and in our service. It’s a difference that has kept customers loyal to us for decades and has earned us customer quality awards year after year.

A History of Leadership:

From our beginnings as a telephone cable manufacturer, SUPERIOR ESSEX has demonstrated leadership and innovation time and time again. We were first to introduce an all-plastic drop wire; first to commercially produce filled cable, first to commercially produce T-Screen compartmented cable. We have continued this tradition through the creation of our Product Development Center, which is dedicated to cabling innovations and is staffed by an R&D engineering team with over 200 years of experience in fiber optics, materials engineering, and cable manufacturing. Our latest innovation, dry buried wire (pages 41 & 53), is certain to set a new standard for service wire.

Our engineers not only participate in the industry standards groups, but are past and present leaders of critical committees. It has enabled us to bring our total quality commitment to bear on new standards and technologies.

SUPERIOR ESSEX makes eve r y effort to ensure the accuracy of the information contained in this cata-logue at the time of publication.

S p e c i fications, packaging and part numbers detailed within are subject to change. For the most up to date infor-mation, please contact SUPERIOR ESSEX at 770-953-8338.

† Largest sales volume of telecommunications cable and wire in North America.

© 2000 Superior Telecommunications, Inc.

Discover the Difference

Product Breadth:

Throughout this catalog you will find the broadest line of outside plant telecommunications cable and wire in the industry.

Combined with our premises product line, SUPERIOR ESSEX can uniquely offer all telecom cable needs from the central office all the way to the desktop.

Experience Delivers Solutions:

Forty plus years in this business have prov i d e d SUPERIOR ESSEX with a broad and deep experience base. Our engineers are the recog-nized experts in copper cable and regularly provide consultation help for special customer applications. We are committed to delivering solutions, not just products.

Flexibility:

This outside plant cable and wire catalog is ex t e n s ive, but we also receive requests for products with special requirements. Our staff r egularly quotes and manufactures custom designs for customers around the world. Speed and effi c i e n cy are our hallmarks.

Defining Quality:

SUPERIOR ESSEX has ISO 9000 registration at every Communications Group production fa c i l i t y, assuring a level of quality and consistency of the c o m p a ny ’s products and service. But there is much more to our commitment to quality. Bey o n d quality assurance of our products is our dedication to bring value added ele-ments and superior customer service to our products.

4 superioressex.com

Table of Contents

RUS Copper Cables

SEALPIC® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7

SEALPIC®-84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9

SEALPIC®-FSF-84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11

SEALPIC®-FSF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13

CUPIC®-FSF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15

GOPIC®-FSF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-17

CASPIC®-FSF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19

SEALPIC®-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21

CUPIC®-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23

GOPIC®-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25

CASPIC®-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27

BELL Copper Cables

ALPETH (BHBA/BHAA/BKMA/BKTA) . . . . . . . . . . . . . . . . . . 28-29

PASP (BHBA/BHAH/BKMA/BKTH) . . . . . . . . . . . . . . . . . . . . 30-31

Self-support (BHBS/BHAS/BKMS/BKTS) . . . . . . . . . . . . . . . 32-33

R e i n f o rced Self-support ( B H B P / B H A P / B K M P / B K T P ) . . . . . . . 34-35

Bonded STALPETH (DCAZ/DCMZ/DCTZ) . . . . . . . . . . . . . 36-37

Filled ALPETH (ANBA/ANAA/ANMA/ANTA) . . . . . . . . . . . . 38-39

Filled ASP (ANBW/ANAW/ANMW/ANTW) . . . . . . . . . . . . . . 40-41

OSP Copper Wire

RUS/RUS Type Wire

ADP, ADP-D, ADP/SR, ADP/SR-D

BDW A-DF, BDW G-DF (Dry Filled)

IMRDW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44-45

BSW A / BSW G . . . . . . . . . . . . . . . . . . . . . . . . . . . 46-47

BDW A / BDW G . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-49

Bell Wire

ASW/F

ADP NMS

ADP S

IM/F

UDPY

BW BRF DF (Dry Filled)

BW BRF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56-57

BW GDJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58-59

Miscellaneous Wire

BSW NSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60-61

Cross-Connect Wire

Ground Wire

Temporary Drop Wire

T-SCREEN® Cables

T-Screen® Filled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64-65

T-Screen® Filled ASP (KNAW/KNMW) . . . . . . . . . . . . . . . 66-67

CANADIAN Copper Cable/Wire

CELFIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68-69

ALPETH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70-71

MUDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72-73

BCBD

ADW

Speciality Cables

OSP Broadband Category 5 . . . . . . . . . . . . . . . . . . . . 76-77

BroadGain™-CX

Series 6 Coax Drop

Series 7 Coax Drop

Series 11 Coax Drop

BroadGain™-CF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80-81

FIBER OPTIC Cables

Single Loose Tube Indoor/Outdoor Riser

Loose Tube Indoor/Outdoor Riser

Single Loose Tube All-Dielectric Cables

Single Loose Tube Single Armor Cables

Loose Tube Single Jacket All-Dielectric

Loose Tube Single Jacket Single Armor

Loose Tube Double Jacket Single Armor

Loose Tube Triple Jacket Double Armor

CATV Cables

Supplemental Part Numbers . . . . . . . . . . . . . . . . . . . 91-93

Miscellaneous

Cable and Wire Acronyms

Technical Section

Color Code Charts . . . . . . . . . . . . . . . . . . . . . . . . . 95-95

Cable Lay-ups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96-99

T-Screen® Designs (Tech Tip)

T-Screen® Placement of Service Pairs

T-Screen® Technical Information

T-Screen® Lay-up Diagrams . . . . . . . . . . . . . . . . 103-105

Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106-108

Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109-111

Product Warranty

Standard Terms & Conditions

5superioressex.com

SUPERIOR ESSEX Cable and Wire Acronyms

ADP = aerial drop ADP-D = aerial drop, dumbbell shape ADP-S = aerial drop, shielded ADP NMS = aerial drop, non metallic strength member ADP/SR = aerial drop, super reduced ADP/SR-D = aerial drop, super reduced, dumbbell shape

ASW/F = aerial service wire / F drop

BDW A = buried distribution wire, aluminum BDW A-DF = buried distribution wire, aluminum, dry filled BDW G = buried distribution wire, gopher

BDW G-DF = buried distribution wire, gopher, dry filled BSW A = buried service wire, aluminum BSW G = buried service wire, gopher BSW NSE = buried service wire, non-shielded ETPR BW BRF = buried wire bronze filled BW BRF-DF = buried wire bronze filled, dry filled BW GDJ = buried wire gopher double jacket

IMRDW = intregal messenger, rural distribution wire IM/F = intregal messenger, F multiple

UDP-Y = universal drop, yarn

RUS Cable Design Coding Plan

SEALPIC®

SEALPIC®-F

SEALPIC®-F – T1

SEALPIC®-FSF

SEALPIC®-84

SE = Sealed shield AL = 0.008” coated aluminum shield PIC = Plastic Insulated Conductors F = solid insulated Filled cable FSF = Foamed Skin insulated Filled 8 = Figure 8 Construction 4 = 0.25” messenger T1 = two core compartments for use in PCM applications

CASPIC®

CASPIC®-F

CASPIC®-F – T1

CASPIC®-FSF

C = Coated shield A = 0.008” Aluminum shield S = 0.006” Steel shield PIC = Plastic Insulated Conductors F = solid insulated Filled cable FSF = Foamed Skin insulated Filled T1 = two core compartments for use in PCM applications

CUPIC®

CUPIC®-F

CUPIC®-F – T1

CUPIC®-FSF

CU = 0.005” Copper shield PIC = Plastic Insulated Conductors F = solid insulated Filled cable FSF = Foamed Skin insulated Filled T1 = two core compartments for use in PCM applications

GOPIC®

GOPIC®-F

GOPIC®-F – T1

GOPIC®-FSF

G O = copper clad steel or copper alloy shield PIC = Plastic Insulated Conductors F = solid insulated Filled cable\ FSF = Foamed Skin insulated Filled T1 = two core compartments for use in PCM applications

Bell Cable Design Coding Plan

The first letter designates the cable design:

A = filled B = air core C = high potential (zone of influence) D = duct K = Screened

The second letter designates the conductor insulation:

C = air core foam skin H = solid air core K = solid air core (high dielectric) N = filled foam skin

The third letter designates the conductor gauge size (AW G ) :

B = 19 AWG

A = 22 AWG

M = 24 AWG

T = 26 AWG

The fourth letter designates the sheath design:

A = ALPETH (bare aluminum) H = PASP (jacket/bare aluminum/steel/jacket) P = reinforced self support (jacket/coated aluminum/steel/jacket) S = self support (coated aluminum) W = ASP (bare aluminum/steel) Z = bonded STALPETH (steel/coated aluminum)

EXAMPLES

ANMW = filled, foam skin, 24 AWG, bare aluminum/steel BKTP = air core, high dielectric, 26 AWG, jacket/coated alu-minum/steel/jacket cable design

OSP Wire Design Coding Plan

SEALPIC ®

Product Description

• SEALPIC® cables are designed primarily for aerial use. In this application, the cable must be attached to a support strand (messenger). If the cable is to be placed in a duct, the cable must be pressurized. SEALPIC® cables, in 19, 22 and 24 AWG, are capable of meeting the electrical requirements of 100 ohms, Category 3, Backbone UTP cables as specified in TIA/EIA-568-A.

Physical Description:

• CONDUCTORS: Solid annealed copper in 19, 22, 24 and 26 AWG.

• INSULATION: Conductors are insulated with solid polyolefin, color coded in accordance with industry standards.

• TWISTED PAIRS: Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk and specific color combi-nations to provide pair identification.

• CORE ASSEMBLY: Cables of 25 pairs or less are assembled into a cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to assemble the core. Units are individu-ally identifiable by color coded unit binders.

• CORE WRAP: A non-hygroscopic, dielectric tape is applied over the core assembly to provide protection for the core.

• SHIELDING: A corrugated, copolymer coated, 8-mil aluminum tape is applied longitudinally with an overlap.

• JACKET: A black, linear low-density polyethylene jacket is applied overall. The jacket provides a tough protective covering designed to withstand exposure to direct sunlight, atmospheric temperature changes and stresses expected in standard installations.

• JACKET MARKINGS: Information such as manufacturer’s identifica-tion, pair count AWG, product identification and a telephone hand-set is printed at 2 ft. intervals on the cable jacket. Sequential footage markings are printed at alternate 2 ft. intervals.

• OPTIONAL DESIGNS: SEALPIC® is available with an internal screen for use with carrier T1 systems. (See page 62)

Copper Toll Free 800-551-8948 — Copper Fax 770-303-8807 superioressex.com

Electrical Specifications

Average Mutual Capacitance at 1000 Hz

Total Number of Pairs nF/mile nF/km

12 or less 83 ± 7 52 ± 4 Over 12 83 ± 4 52 ± 2

Conductor Minimum Insulation Max Average Attenuation Max Conductor Resistance Dielectric Strength

Size Resistance @ 68° F (20° C) Resistance @ 68°F (20° C) Unbalance DC Potential – Volts 68° F (20° C) 772 kHz Ohms Maximum Minimum gigohm/ gigohm/ Individual Cdr. to Cdr. to AWG mm mile km dB/kft dB/km mile km Ave % Pair % Cdr. Grnd.

19 0.90 1.0 1.6 3.3 10.9 45.0 28.0 1.5 5.0 5,000 10,000 22 0.64 1.0 1.6 4.6 15.3 91.0 56.5 1.5 5.0 4,000 10,000 24 0.50 1.0 1.6 5.7 19.4 144.0 89.5 1.5 5.0 3,000 10,000 26 0.40 1.0 1.6 7.2 23.6 232.0 144.2 1.5 5.0 2,400 10,000

Near End Crosstalk (NEXT) at 150 kHz 772 kHz

P.S.WUNEXT mean (dB) 58 47 P.S.WUNEXT worst pair (dB) 53 42

Far End Crosstalk at 150 kHz

Conductor size (AWG) 19 22 24 26 P.S. ELFEXT mean (dB/kft) 65 63 63 61 P.S. ELFEXT worst pair (dB/kft) 59 57 57 57

Far End Crosstalk at 772 kHz

Conductor size (AWG) 19 22 24 26 P.S. ELFEXT mean (dB/kft) 51 49 49 47 P.S. ELFEXT worst pair (dB/kft) 45 43 43 43

Capacitance Unbalance Pair to Pair

Pairs Maximum Individual Maximum RMS pF/kft pF/km pF/kft pF/km

12 or less 80 145 — — more than 12 80 145 25 45

Capacitance Unbalance Pair to Ground

Pairs Maximum Individual Maximum Average pF/kft pF/km pF/kft pF/km

12 or less 800 2625 — — more than 12 800 2625 175 574

*for cables of 12 pairs or less, the maximum average attenuation may be increased by 10% over the values shown.

SEALPIC ®

Copper Toll Free 800-551-8948 — Copper Fax 770-303-8807 superioressex.com

Part Numbers and Physical Characteristics

Part # Pair Count Nominal O.D. Approx. Weight Standard Length Standard Reel Size Approx. Shipping Weight in mm lbs/kft kg/km ft m f x t x d lbs kg

19 AWG (0.90 mm) 01-026-40 6 0.54 14 108 161 5000 1525 44 x 18 x 20 650 295 01-028-40 12 0.66 17 180 268 5000 1525 46 x 25 x 20 1060 480 01-031-40 25 0.82 21 325 484 5000 1525 58 x 25 x 20 1880 853

01-034-40 50 1.06 27 593 883 5000 1525 72 x 25 x 20 3590 1628 01-038-40 100 1.46 37 1169 1741 5000 1525 84 x 36 x 39 6670 3026 22 AWG (0.64 mm) 01-057-40 6 0.46 12 69 103 5000 1525 36 x 18 x 14 410 186 01-059-40 12 0.54 14 109 162 5000 1525 44 x 18 x 20 650 295 01-062-40 25 0.66 17 184 274 5000 1525 46 x 25 x 20 1090 495 01-065-40 50 0.82 21 324 483 5000 1525 52 x 25 x 20 1830 830 01-069-40 100 1.06 27 589 877 5000 1525 62 x 30 x 24 3250 1474 01-073-40 200 1.45 37 1166 1737 5000 1525 84 x 40 x 42 6660 3021 01-075-40 300 1.71 43 1677 2498 2500 762 78 x 40 x 39 4910 2227 01-077-40 400 1.95 50 2208 3289 2500 762 78 x 40 x 39 6260 2840 01-081-40 600 2.36 60 3239 4825 1250 380 72 x 36 x 39 4690 2127 01-083-40 900 2.86 73 4766 7099 1250 380 84 x 40 x42 6790 3080 01-085-40 1200 3.21 82 6245 9302 1000 305 96 x 40 x 48 7420 3365 24 AWG (0.50 mm) 01-092-40 6 0.38 10 54 80 5000 1525 30 x 18 x 12 320 145 01-094-40 12 0.46 12 81 121 5000 1525 36 x 18 x 14 470 213 01-097-40 25 0.53 13 132 197 5000 1525 44 x 18 x 20 770 349 01-100-40 50 0.67 17 225 335 5000 1525 46 x 25 x 20 1300 590 01-104-40 100 0.87 22 401 597 5000 1525 58 x 25 x 20 2270 1030 01-108-40 200 1.16 29 750 1117 5000 1525 72 x 36 x 39 4390 1991 01-110-40 300 1.40 36 1126 1677 5000 1525 78 x 40 x 39 6360 2885 01-112-40 400 1.55 39 1456 2169 2500 760 72 x 36 x 39 4280 1941 01-116-40 600 1.88 48 2128 3170 2500 760 78 x 40 x 39 6050 2744 01-118-40 900 2.27 58 3119 4646 1250 380 72 x 36 x 39 4540 2059 01-120-40 1200 2.58 66 4108 6119 1250 380 78 x 40 x 39 5870 2663

01-121-40 1500 2.89 73 5060 7537 1250 380 96 x 40 x 48 7540 3420 01-124-40 1800 3.21 82 6006 8946 1000 305 84 x 40 x 42 6840 3103 01-125-40 2100 3.39 86 6945 1345 1000 305 96 x 40 x 48 8170 3706 01-126-40 2400 3.64 92 7884 11744 750 230 96 x 40 x 48 7130 3234 26 AWG (0.40 mm) 01-132-40 25 0.50 13 96 143 5000 1525 36 x 18 x 14 540 245 01-135-40 50 0.62 16 157 234 5000 1525 46 x 25 x 20 960 435 01-139-40 100 0.74 19 270 402 5000 1525 52 x 25 x 20 1560 708 01-143-40 200 0.98 25 486 724 5000 1525 62 x 30 x 24 2740 1243 01-145-40 300 1.14 29 708 1054 5000 1525 72 x 36 x 39 4180 1896 01-147-40 400 1.28 32 938 1397 5000 1525 78 x 40 x 39 5430 2463 01-151-40 600 1.55 39 1373 2045 5000 1525 84 x 40 x 42 7720 3502 01-153-40 900 1.84 47 2008 2991 2500 760 78 x 40 x 39 5760 2613 01-155-40 1200 2.12 54 2640 3932 2500 760 84 x 40 x 42 7450 3379 01-156-40 1500 2.32 59 3242 4829 1250 380 72 x 36 x 39 4700 2132 01-157-40 1800 2.49 63 3871 5766 1250 380 78 x 40 x 39 5580 2531 01-158-40 2100 2.75 70 4467 6654 1250 380 84 x 40 x 42 6430 2917 01-159-40 2400 2.90 74 5062 7540 1250 380 96 x 40 x 48 7560 3429

Standards Compliance:

ANSI/ICEA S-85-625-1996; Formerly manufactured to REA Specification PE-22 (PE-22 was deactivated by RUS and is superseded by ANSI/ICEA specifications).

SEALPIC ®-84

Product Description

• SEALPIC®-84 cables are designed for aerial installations. The core and support member (messenger) lay parallel to each other forming a cross-sectional “figure 8”. The messenger is an integral part of the cable sheath, yet readily available for gripping, pulling and tensioning. Installation is fast and easy using standard methods and hardware. SEALPIC®-84 cables, in 19, 22 and 24 AWG are capable of meeting the electrical require-ments of 100 ohms, Category 3, Backbone UTP Cables as specified in TIA/EIA-568-A.

Physical Description

• CONDUCTORS: Solid annealed copper in 19, 22, 24 and 26 AWG

• INSULATION: Conductors are insulated with solid polyolefin, color coded in accordance with industry standards.

• TWISTED PAIRS: Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk and specific color combi-nations to provide pair identification.

• CORE ASSEMBLY: Cables of 25 pairs or less are assembled into a cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to assemble the core. Units are individu-ally identifiable by color coded unit binders.

• CORE WRAP: A non-hygroscopic, dielectric tape is applied over the core assembly to provide protection for the core.

• SHIELDING: A corrugated, copolymer coated, 8-mil aluminum tape is applied longitudinally with an overlap.

• SUPPORT MEMBER: A 1/4 inch, 7-strand Extra High Strength (EHS) galvanized steel messenger serves as the support member and is an integral part of the sheath. The messenger is flooded to inhibit corrosion.

• JACKET: A black, linear low-density polyethylene jacket is applied overall. The jacket provides a tough protective covering designed to withstand exposure to direct sunlight, atmospheric temperature changes and stresses expected in standard installations.

• JACKET MARKINGS: Information such as manufacturer’s identifica-tion, pair count AWG, product identification and a telephone hand-set is printed at 2 ft. intervals on the cable jacket. Sequential footage markings are printed at alternate 2 ft. intervals.

Electrical Specifications

Average Mutual Capacitance at 1000 Hz

Total Number of Pairs nF/mile nF/km

12 or less 83 ± 7 52 ± 4 Over 12 83 ± 4 52 ± 2

Conductor Minimum Insulation Max Average Attenuation Max Conductor Resistance Dielectric Strength

Size Resistance @ 68° F (20° C) Resistance @ 68°F (20° C) Unbalance DC Potential – Volts 68° F (20° C) 772 kHz Ohms Maximum Minimum gigohm/ gigohm/ Individual Cdr. to Cdr. to AWG mm mile km dB/kft dB/km mile km Ave % Pair % Cdr. Grnd.

19 0.90 1.0 1.6 3.3 10.9 45.0 28.0 1.5 5.0 5,000 10,000 22 0.64 1.0 1.6 4.6 15.3 91.0 56.5 1.5 5.0 4,000 10,000 24 0.50 1.0 1.6 5.7 19.4 144.0 89.5 1.5 5.0 3,000 10,000 26 0.40 1.0 1.6 7.2 23.6 232.0 144.2 1.5 5.0 2,400 10,000

Near End Crosstalk (NEXT) at 150 kHz 772 kHz

P.S.WUNEXT mean (dB) 58 47 P.S.WUNEXT worst pair (dB) 53 42

Far End Crosstalk at 150 kHz

Conductor size (AWG) 19 22 24 26 P.S. ELFEXT mean (dB/kft) 65 63 63 61 P.S. ELFEXT worst pair (dB/kft) 59 57 57 57

Far End Crosstalk at 772 kHz

Conductor size (AWG) 19 22 24 26 P.S. ELFEXT mean (dB/kft) 51 49 49 47 P.S. ELFEXT worst pair (dB/kft) 45 43 43 43

Capacitance Unbalance Pair to Pair

Pairs Maximum Individual Maximum RMS pF/kft pF/km pF/kft pF/km

12 or less 80 145 — — more than 12 80 145 25 45

Capacitance Unbalance Pair to Ground

Pairs Maximum Individual Maximum Average pF/kft pF/km pF/kft pF/km

12 or less 800 2625 — — more than 12 800 2625 175 574

*for cables of 12 pairs or less, the maximum average attenuation may be increased by 10% over the values shown.

Copper Toll Free 800-551-8948 — Copper Fax 770-303-8807 superioressex.com

SEALPIC ®-84

Part Numbers and Physical Characteristics

Part # Pair Count Cable Only O.D. Overall O.D. Approx. Weight Standard Length Standard Reel Size Approx. Shipping Weight in mm in mm lbs/kft kg/km ft m f x t x d lbs kg

19 AWG (0.90 mm) 01-026-38 6 0.48 12 0.96 24 272 405 5000 1525 72 x 36 x 39 1840 835 01-028-38 12 0.60 15 1.08 27 343 511 5000 1525 58 x 25 x 20 1830 830 01-031-38 25 0.80 20 1.28 33 496 739 5000 1525 78 x 40 x 39 3040 1380 01-034-38 50 1.08 27 1.56 40 765 1140 5000 1525 84 x 40 x 42 4490 2040 01-038-38 100 1.43 36 1.91 49 1312 1954 2500 760 72 x 36 x 39 3820 1733 22 AWG (0.64 mm) 01-057-38 6 0.40 10 0.88 22 232 346 5000 1525 58 x 25 x 20 1290 585 01-059-38 12 0.48 12 0.96 24 270 402 5000 1525 62 x 30 x 24 1510 685 01-062-38 25 0.60 15 1.08 27 345 514 5000 1525 72 x 36 x 39 2220 1010 01-065-38 50 0.80 20 1.28 33 492 733 5000 1525 78 x 40 x 39 3050 1380 01-069-38 100 1.07 27 1.55 39 771 1148 2500 760 62 x 30 x 24 2160 980 01-073-38 200 1.43 36 1.91 49 1316 1960 2500 760 72 x 36 x 39 3860 1751

24 AWG (0.50 mm) 01-092-38 6 0.36 9 0.84 21 217 323 5000 1525 46 x 25 x 20 1130 513 01-094-38 12 0.40 10 0.88 22 243 362 5000 1525 52 x 25 x 20 1300 590 01-097-38 25 0.51 13 0.99 25 293 436 5000 1525 58 x 25 x 20 1590 721 01-100-38 50 0.65 17 1.13 29 383 571 5000 1525 62 x 30 x 24 2100 953 01-104-38 100 0.86 22 1.34 34 567 845 5000 1525 72 x 36 x 39 3350 1520 01-108-38 200 1.15 29 1.63 41 913 1360 2500 760 62 x 30 x 24 2540 1152 01-110-38 300 1.39 35 1.87 47 1265 1884 2500 760 72 x 36 x 39 3760 1706 26 AWG (0.40 mm) 01-132-38 25 0.45 12 0.93 24 256 381 5000 1525 52 x 25 x 20 1370 623 01-135-38 50 0.56 14 1.04 26 316 471 5000 1525 58 x 25 x 20 1720 780 01-139-38 100 0.73 19 1.21 31 427 636 5000 1525 62 x 30 x 24 2320 1052 01-143-38 200 0.93 24 1.41 36 649 967 5000 1525 72 x 36 x 39 3780 1715 01-145-38 300 1.11 28 1.59 40 870 1296 2500 760 62 x 30 x 24 2430 1102 01-147-38 400 1.25 32 1.73 44 1077 1604 2500 760 72 x 36 x 39 3020 1370

Standards Compliance:

ANSI/ICEA S-85-625-1996; Formerly manufactured to REA Specification PE-38, PE-38 was deactivated by RUS (REA) in 1993 and is superseded by the ANSI/ICEA specifications.

Product Description

• SEALPIC‚-FSF-84 cables are designed for aerial applications where a filled cable design is preferred. The core and support member (messenger) lay parallel to each other forming a cross-sectional “figure 8”. The messenger is an integral part of the cable sheath, yet readily available for gripping, pulling and tensioning. Installation is accomplished using standard methods and hardware. SEALPIC‚-FSF-84 cables in 22 and 24 AWG are capable of meeting the electrical requirements of 100 ohms, Category 3, Backbone UTP Cables as specified in TIA/EIA-568-A.

Physical Descriptoin CONDUCTORS: Solid annealed bare copper in 22 and 24 AWG.

INSULATION: Conductors are dual insulated with an inner layer of foamed, natural polyolefin covered by an outer layer of solid, colored polyolefin. The conductor insulation is color-coded in accordance with industry standards.

TWISTED PAIRS: Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk and specific color combina-tions to provide pair identification.

CORE ASSEMBLY: Cables of 25 pairs and less are assembled into a cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to assemble the core. Units are individually identifiable by color-coded binders.

FILLING COMPOUND: The core assembly is filled with an 80∞ C ETPR compound, completely filling the interstices between the pairs and under the core wrap.

CORE WRAP: A non-hygroscopic, dielectric tape is applied over the core assembly to provide protection for the core.

SHIELDING: A corrugated, copolymer coated, 8-mil aluminum tape is applied longitudinally with an overlap. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.

SUPPORT MEMBER: A ? inch, 7-strand Extra High Strength (EHS) gal-vanized steel messenger serves as the support member and is an integral part of the sheath. The messenger is flooded to inhibit corro-sion.

JACKET: A black, linear low-density polyethylene jacket is applied overall. The jacket provides a tough protective covering designed to withstand exposure to direct sunlight, atmospheric temperatur e changes and stresses expected in standard installations.

JACKET MARKINGS: Information including the manufacturer’s identi-fication, pair count, AWG and product code appears at 2-foot inter-vals. Sequential length markings appear at alternate 2-foot intervals.

Copper Toll Free 800.000.0000 — Copper Fax 000.000.0000 superioressex.com

SEALPIC ®-FSF-84

Electrical Specifications

Average Mutual Capacitance at 1000 Hz

Total Number of Pairs nF/mile nF/km

12 or less 83 ± 7 52 ± 4 Over 12 83 ± 4 52 ± 2

Conductor Minimum Insulation Max Average Attenuation Max Conductor Resistance Dielectric Strength

Size Resistance @ 68° F (20° C) Resistance @ 68°F (20° C) Unbalance DC Potential – Volts 68° F (20° C) 772 kHz Ohms Maximum Minimum gigohm/ gigohm/ Individual Cdr. to Cdr. to AWG mm mile km dB/kft dB/km mile km Ave % Pair % Cdr. Grnd.

22 0.64 1.0 1.6 4.5 14.8 91.0 56.6 1.5 5.0 3,600 10,000 24 0.50 1.0 1.6 5.6 18.4 144.0 89.5 1.5 5.0 3,000 10,000

Near End Crosstalk (NEXT) at 150 kHz 772 kHz

P.S.WUNEXT mean (dB) 58 47 P.S.WUNEXT worst pair (dB) 53 42

Far End Crosstalk at 150 kHz

Conductor size (AWG) 22 24 P.S. ELFEXT mean (dB/kft) 63 63 P.S. ELFEXT worst pair (dB/kft) 57 57

Far End Crosstalk at 772 kHz

Conductor size (AWG) 22 24 P.S. ELFEXT mean (dB/kft) 49 49 P.S. ELFEXT worst pair (dB/kft) 43 43

Capacitance Unbalance Pair to Pair

Pairs Maximum Individual Maximum RMS pF/kft pF/km pF/kft pF/km

12 or less 80 145 — — more than 12 80 145 25 45

Capacitance Unbalance Pair to Ground

Pairs Maximum Individual Maximum Average pF/kft pF/km pF/kft pF/km

12 or less 800 2625 — — more than 12 800 2625 175 574

11Copper Toll Free 000.000.0000 — Copper Fax 000.000.0000

Part Numbers and Physical Characteristics

Part # Pair Count Cable OD Overall O.D. Approx. Weight Standard Length in/mm in/mm lbs/kft kg/km ft m

22 AWG (0.64 mm) 09-057-05 6 0.45/11 .93/23 217 323 5000 1525 09-059-05 12 0.53/13 1.01/25 262 390 5000 1525 09-062-05 25 0.67/17 1.15/29 350 521 5000 1525 09-065-05 50 0.85/22 1.33/34 522 777 5000 1525

24 AWG (0.5 mm) 09-092-05 6 0.39/ 10 .87 / 22 199 296 5000 1525 09-094-05 12 0.44/ 11 .92 / 23 229 341 5000 1525

09-097-05 25 0.57/ 14 1.05 / 26 288 429 5000 1525 09-100-05 50 0.73/ 19 1.21 / 31 394 586 5000 1525 09-104-05 100 0.93/ 24 1.41 / 36 608 905 5000 1525 09-108-05 200 1.21/ 31 1.69 / 43 1013 1508 2500 760

Standards Compliance:

SEALPIC‚-FSF-84 cables meet the physical and electrical requirements of RUS specification 7 CFR 1755.890 (PE-89), latest issue except that the figure-8 sheath shall meet the requirements of ANSI/ICEA S-85-625-1996, Option A.

SEALPIC ®-FSF-84

SEALPIC ®-FSF

Product Description

• SEALPIC®-FSF cables are designed for direct burial or duct applications where protection from moisture is required. SEALPIC®-FSF may be used aerially, but must be attached to a support strand (messenger). SEALPIC®-FSF cables, in 19, 22 and 24 AWG, are capable of meeting the electrical requirements of 100 ohms, Category 3, Backbone UTP Cables as specified in TIA/EIA-568-A.

Physical Description

• CONDUCTORS: Solid annealed copper in 19, 22, 24 and 26 AWG.

• INSULATION: Conductors are dual insulated with an inner layer of foamed, natural polyolefin covered by an outer layer of solid, colored polyolefin. The conductor insulation is color coded in accordance with industry standards.

• TWISTED PAIRS: Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk and specific color combi-nations to provide pair identification.

• CORE ASSEMBLY: Cables of 25 pairs or less are assembled into a cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to assemble the core. Units are individu-ally identifiable by color coded unit binders.

• FILLING COMPOUND: The core assembly is filled with an 80° C ETPR compound, completely filling the interstices between the pairs and under the core wrap.

• CORE WRAP: A non-hygroscopic, dielectric tape is applied over the core assembly to provide protection for the core.

• SHIELDING: A corrugated, copolymer coated, 8-mil aluminum tape is applied longitudinally with an overlap. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.

• JACKET: A black, linear low-density polyethylene jacket is applied overall. The jacket provides a tough protective covering designed to withstand exposure to direct sunlight, atmospheric temperature changes and stresses expected in standard installations.

• JACKET MARKINGS: Information such as manufacturer's identifica-tion, pair count, AWG, product identification and a telephone hand-set is printed at 2 ft. intervals on the cable jacket. Sequential footage markings are printed at alternate 2 ft. intervals.

• OPTIONAL DESIGNS: SEALPIC®-FSF is available with an internal screen for use with T-Carrier systems.

• SEALPIC®-FSF is available with mechanical protection.

Electrical Specifications

Average Mutual Capacitance at 1000 Hz

Total Number of Pairs nF/mile nF/km

12 or less 83 ± 7 52 ± 4 Over 12 83 ± 4 52 ± 2

Conductor Minimum Insulation Max Average Attenuation Max Conductor Resistance Dielectric Strength

Size Resistance @ 68° F (20° C) Resistance @ 68°F (20° C) Unbalance DC Potential – Volts 68° F (20° C) 772 kHz Ohms Maximum Minimum gigohm/ gigohm/ Individual Cdr. to Cdr. to AWG mm mile km dB/kft dB/km mile km Ave % Pair % Cdr. Grnd.

19 0.90 1.0 1.6 3.2 10.5 45.0 28.0 1.5 5.0 4,500 10,000 22 0.64 1.0 1.6 4.5 14.8 91.0 56.6 1.5 5.0 3,600 10,000 24 0.50 1.0 1.6 5.6 18.4 144.0 89.5 1.5 5.0 3,000 10,000 26 0.40 1.0 1.6 7.0 23.3 232.0 144.0 1.5 5.0 2,400 10,000

Near End Crosstalk (NEXT) at 150 kHz 772 kHz

P.S.WUNEXT mean (dB) 58 47 P.S.WUNEXT worst pair (dB) 53 42

Far End Crosstalk at 150 kHz

Conductor size (AWG) 19 22 24 26 P.S. ELFEXT mean (dB/kft) 65 63 63 61 P.S. ELFEXT worst pair (dB/kft) 59 57 57 57

Far End Crosstalk at 772 kHz

Conductor size (AWG) 19 22 24 26 P.S. ELFEXT mean (dB/kft) 51 49 49 47 P.S. ELFEXT worst pair (dB/kft) 45 43 43 43

Capacitance Unbalance Pair to Pair

Pairs Maximum Individual Maximum RMS pF/kft pF/km pF/kft pF/km

12 or less 80 145 — — more than 12 80 145 25 45

Capacitance Unbalance Pair to Ground

Pairs Maximum Individual Maximum Average pF/kft pF/km pF/kft pF/km

12 or less 800 2625 — — more than 12 800 2625 175 574

*for cables of 12 pairs or less, the maximum average attenuation may be increased by 10% over the values shown.

SEALPIC ®-FSF

Part Numbers and Physical Characteristics

Part # Pair Count Nominal O.D. Approx. Weight Standard Length Standard Reel Size Approx. Shipping Weight in mm lbs/kft kg/km ft m f x t x d lbs kg

19 AWG (0.90 mm) 09-026-02 6 0.55 14 127 189 5000 1525 44 x 18 x 20 740 336 09-028-02 12 0.65 17 211 314 5000 1525 46 x 25 x 20 1210 549 09-031-02 25 0.86 22 382 569 5000 1525 58 x 25 x 20 2140 971 09-034-02 50 1.13 29 693 1032 5000 1525 72 x 36 x 39 4070 1846 09-038-02 100 1.50 38 1320 1966 2500 760 62 x 30 x 24 3590 1628

22 AWG (0.64 mm) 09-057-02 6 0.45 11 82 122 5000 1525 36 x 18 x 14 460 209 09-059-02 12 0.53 13 130 194 5000 1525 44 x 18 x 20 740 336 09-062-02 25 0.67 17 221 329 5000 1525 46 x 25 x 20 1260 572 09-065-02 50 0.85 22 386 575 5000 1525 58 x 25 x 20 2170 984 09-069-02 100 1.13 29 701 1044 5000 1525 72 x 36 x 39 4110 1864 09-073-02 200 1.45 37 1334 1987 2500 760 62 x 30 x 24 3620 1642 09-075-02 300 1.76 45 1942 2893 1250 380 62 x 30 x 24 2710 1229 09-077-02 400 2.02 51 2545 3791 1250 380 62 x 30 x 24 3480 1579 09-081-02 600 2.40 61 3740 5571 1250 380 72 x 36 x 39 5300 2404 09-083-02 900 2.94 75 5516 8217 1250 380 96 x 40 x 48 8090 3670 09-085-02 1200 3.46 88 7279 1843 1000 380 96 x 40 x 48 8454 3834 24 AWG (0.50 mm) 09-092-02 6 0.39 10 64 95 5000 1525 30 x 18 x 12 360 163 09-094-02 12 0.44 11 96 143 5000 1525 36 x 18 x 14 530 240 09-097-02 25 0.57 14 157 234 5000 1525 44 x 18 x 20 880 399 09-100-02 50 0.73 19 266 396 5000 1525 46 x 25 x 20 1480 671 09-104-02 100 0.93 24 472 703 5000 1525 58 x 25 x 20 2600 1179 09-108-02 200 1.21 31 864 1287 5000 1525 72 x 36 x 39 4920 2232 09-110-02 300 1.42 36 1273 1896 2500 760 52 x 25 x 20 3460 1569 09-112-02 400 1.61 41 1660 2473 2500 760 58 x 25 x 20 4760 2159 09-116-02 600 2.01 51 2425 3612 1250 380 62 x 30 x 24 3320 1506 09-118-02 900 2.39 61 3563 5307 1250 380 72 x 36 x 39 5070 2300 09-120-02 1200 2.72 69 4689 6985 1000 305 84 x 40 x 42 5310 2409 09-121-02 1500 2.97 75 5812 8658 1000 305 78 x 40 x 39 6520 2957

09-124-02 1800 3.30 84 6929 10172 1000 305 84 x 40 x 42 7740 3511 09-125-02 2100 3.54 90 8028 11959 1000 305 96 x 40 x 48 9220 4182 09-126-02 2400 3.78 96 8893 13248 750 230 96 x 40 x 48 8030 3642 26 AWG (0.40 mm) 09-132-02 25 0.49 12 115 171 5000 1525 44 x 18 x 20 670 305 09-135-02 50 0.61 15 188 280 5000 1525 46 x 25 x 20 1100 499 09-139-02 100 0.77 20 323 481 5000 1525 52 x 25 x 20 1810 820 09-143-09 200 1.01 26 581 865 5000 1525 62 x 30 x 24 3180 1440 09-145-09 300 1.21 31 829 1235 5000 1525 72 x 36 x 39 4740 2150 09-147-02 400 1.37 35 1093 1628 2500 760 62 x 30 x 24 3020 1370 09-151-02 600 1.60 41 1588 2365 2500 760 72 x 36 x 39 4580 2080 09-153-02 900 2.02 51 2201 3451 1250 380 62 x 30 x 24 3190 1450 09-155-02 1200 2.20 56 3043 4523 1250 380 72 x 36 x 39 4420 2000 09-156-02 1500 2.44 62 3761 5602 1250 380 72 x 36 x 39 5320 2410 09-157-02 1800 2.72 69 4475 6666 1250 380 78 x 40 x 39 6300 2860 09-159-02 2400 3.05 77 5903 8793 1250 380 96 x 40 x 48 8570 3890 09-164-02 3600 3.78 96 8489 12646 1000 305 96 x 40 x 48 9660 4382

Standards Compliance:

ANSI/ICEA S-84-608-1994; RUS 7 CFR 1755.890 (PE-89)

CUPIC ®-FSF

Product Description

• CUPIC®-FSF cables are designed for direct burial or duct applications where protection from moisture is required. CUPIC®-FSF may be used aerially, but must be attached to a support strand (messenger). CUPIC®-FSF cables, in 19, 22 and 24 AWG, are capable of meeting the electrical requirements of 100 ohms, Category 3, Backbone UTP Cables as specified in TIA/EIA-568-A.

Physical Description

• CONDUCTORS: Solid annealed copper in 19, 22, and 24 AWG.

• INSULATION: Conductors are dual insulated with an inner layer of foamed, natural polyolefin covered by an outer layer of solid, colored polyolefin. The conductor insulation is color coded in accordance with industry standards.

• TWISTED PAIRS: Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk and specific color combinations to provide pair identification.

• CORE ASSEMBLY: Cables of 25 pairs or less are assembled into a cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to assemble the core. Units are individu-ally identifiable by color coded unit binders.

• FILLING COMPOUND: The core assembly is filled with an 80° C ETPR compound, completely filling the interstices between the pairs and under the core wrap.

• CORE WRAP: A non-hygroscopic, dielectric tape is applied over the core assembly to provide protection for the core.

• SHIELDING: A corrugated 5-mil copper tape is applied longitudinally with an overlap. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.

• JACKET: A black, linear low-density polyethylene jacket is applied overall. The jacket provides a tough protective covering designed to withstand exposure to direct sunlight, atmospheric temperature changes and stresses expected in standard installations.

• JACKET MARKINGS: Information, such as manufacturer's identifi -cation, pair count AWG, product identification and a telephone handset is printed at 2 ft. intervals on the cable jacket. Sequential footage markings are printed at alternate 2 ft. intervals.

• OPTIONAL DESIGNS: CUPIC®-FSF is available with an internal screen for use with T-Carrier systems.

• CUPIC®-FSF is available with mechanical protection.

Electrical Specifications

Average Mutual Capacitance at 1000 Hz

Total Number of Pairs nF/mile nF/km

12 or less 83 ± 7 52 ± 4 Over 12 83 ± 4 52 ± 2

Conductor Minimum Insulation Max Average Attenuation Max Conductor Resistance Dielectric Strength

Size Resistance @ 68° F (20° C) Resistance @ 68°F (20° C) Unbalance DC Potential – Volts 68° F (20° C) 772 kHz Ohms Maximum Minimum gigohm/ gigohm/ Individual Cdr. to Cdr. to AWG mm mile km dB/kft dB/km mile km Ave % Pair % Cdr. Grnd.

19 0.90 1.0 1.6 3.2 10.5 45.0 28.0 1.5 5.0 4,500 10,000 22 0.64 1.0 1.6 4.5 14.8 91.0 56.6 1.5 5.0 3,600 10,000 24 0.50 1.0 1.6 5.6 18.4 144.0 89.5 1.5 5.0 3,000 10,000

Near End Crosstalk (NEXT) at 150 kHz 772 kHz

P.S.WUNEXT mean (dB) 58 47 P.S.WUNEXT worst pair (dB) 53 42

Far End Crosstalk at 150 kHz

Conductor size (AWG) 19 22 24 P.S. ELFEXT mean (dB/kft) 65 63 63 P.S. ELFEXT worst pair (dB/kft) 59 57 57

Far End Crosstalk at 772 kHz

Conductor size (AWG) 19 22 24 P.S. ELFEXT mean (dB/kft) 51 49 49 P.S. ELFEXT worst pair (dB/kft) 45 43 43

Capacitance Unbalance Pair to Pair

Pairs Maximum Individual Maximum RMS pF/kft pF/km pF/kft pF/km

12 or less 80 145 — — more than 12 80 145 25 45

Capacitance Unbalance Pair to Ground

Pairs Maximum Individual Maximum Average pF/kft pF/km pF/kft pF/km

12 or less 800 2625 — — more than 12 800 2625 175 574

*for cables of 12 pairs or less, the maximum average attenuation may be increased by 10% over the values shown.

CUPIC ®-FSF

Part Numbers and Physical Characteristics

Part # Pair Count Nominal O.D. Approx. Weight Standard Length Standard Reel Size Approx. Shipping Weight in mm lbs/kft kg/km ft m f x t x d lbs kg

19 AWG (0.90 mm) 09-026-04 6 0.55 14 142 212 5000 1525 44 x 18 x 20 810 367 09-028-04 12 0.65 17 231 344 5000 1525 46 x 25 x 20 1305 592 09-031-04 25 0.86 22 409 609 5000 1525 58 x 25 x 20 2290 1039 09-034-04 50 1.13 29 731 1089 5000 1525 72 x 36 x 39 4150 1882 09-038-04 100 1.50 38 1370 2041 2500 760 62 x 30 x 24 3650 1656

22 AWG (0.64 mm) 09-057-04 6 0.45 11 94 140 5000 1525 36 x 18 x 14 590 268 09-059-04 12 0.53 13 146 217 5000 1525 44 x 18 x 20 870 395 09-062-04 25 0.67 17 242 360 5000 1525 46 x 25 x 20 1360 617 09-065-04 50 0.85 22 413 615 5000 1525 58 x 25 x 20 2390 1084 09-069-04 100 1.13 29 740 1102 5000 1525 72 x 36 x 39 4140 1878 09-073-04 200 1.45 37 1387 2066 2500 760 58 x 25 x 20 3930 1783 09-075-04 300 1.76 45 2004 2985 1250 380 62 x 30 x 24 2830 1284 09-077-04 400 2.02 51 2615 3895 1250 380 62 x 30 x 24 3710 1683 09-081-04 600 2.40 61 3823 5695 1250 380 72 x 36 x 39 5670 2572 09-083-04 900 2.94 75 5615 8364 1250 380 96 x 40 x 48 8020 3638 09-085-04 1200 3.46 88 7389 11007 1000 305 96 x 40 x 48 8560 3880 24 AWG (0.50 mm) 09-092-04 6 0.39 10 74 110 5000 1525 30 x 18 x 12 410 186 09-094-04 12 0.44 11 109 162 5000 1525 36 x 18 x 14 600 272 09-097-04 25 0.57 14 174 259 5000 1525 44 x 18 x 20 960 435 09-100-04 50 0.73 19 288 429 5000 1525 46 x 25 x 20 1600 726 09-104-04 100 0.93 24 503 749 5000 1525 58 x 25 x 20 2750 1247 09-108-04 200 1.21 31 906 1350 5000 1525 72 x 36 x 39 5130 2327 09-110-04 300 1.42 36 1324 1972 2500 760 72 x 36 x 39 3590 1628 09-112-04 400 1.61 41 1717 2558 2500 760 62 x 30 x 24 4910 2227 09-116-04 600 2.01 51 2493 3714 1250 380 72 x 36 x 39 3400 1542 09-118-04 900 2.39 61 3645 5430 1250 380 62 x 30 x 24 5170 2345 09-120-04 1200 2.72 69 4781 7122 1000 305 72 x 36 x 39 5310 2408 09-121-04 1500 2.97 75 5913 8808 1000 305 78 x 40 x 39 6520 2957

09-124-04 1800 3.30 84 7038 10484 1000 305 84 x 40 x 42 7850 3561 09-125-04 2100 3.54 90 8144 12131 1000 305 96 x 40 x 48 9340 4237 09-126-04 2400 3.78 96 9011 13410 750 230 96 x 40 x 48 7940 3600

Standards Compliance:

ANSI/ICEA S-84-608-1994; RUS 7 CFR 1755.890 (PE-89)

GOPIC ®-FSF

Product Description

• GOPIC®-FSF cables are designed for direct burial or duct applications where protection from moisture is required. GOPIC®-FSF cables are recom-mended for use in high-risk areas where additional mechanical or rodent protection is required. GOPIC®-FSF may be used aerially, but must be attached to a support strand (messenger). GOPIC ®-FSF cables, in 19, 22 and 24 AWG, are capable of meeting the electrical requirements of 100 ohms, Category 3, Backbone UTP Cables as specified in TIA/EIA-568-A.

Physical Description

• CONDUCTORS: Solid annealed copper in 19, 22, and 24 AWG.

• INSULATION: Conductors are dual insulated with an inner layer of foamed, natural polyolefin covered by an outer layer of solid, colored polyolefin. The conductor insulation is color coded in accordance with industry standards.

• TWISTED PAIRS: Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk and specific color combi-nations to provide pair identification.

• CORE ASSEMBLY: Cables of 25 pairs or less are assembled into a cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to assemble the core. Units are individu-ally identifiable by color coded unit binders.

• FILLING COMPOUND: The core assembly is filled with an 80° C ETPR compound, completely filling the interstices between the pairs and under the core wrap.

• CORE WRAP: A non-hygroscopic, dielectric tape is applied over the core assembly to provide protection for the core.

• SHIELDING: A corrugated, gopher resistant, copper alloy or copper clad steel tape is applied longitudinally with an overlap. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.

• JACKET: A black, linear low-density polyethylene jacket is applied overall. The jacket provides a tough protective covering designed to withstand exposure to direct sunlight, atmospheric temperature changes and stresses expected in standard installations.

• JACKET MARKINGS: Information, such as manufacturer's identifi-cation, pair count AWG, product identification and a telephone handset is printed at 2 ft. intervals on the cable jacket. Sequential footage markings are printed at alternate 2 ft. intervals.

• OPTIONAL DESIGNS: GOPIC®-FSF is available with an internal screen for use with T-Carrier systems.

• GOPIC®-FSF is available with mechanical protection.

Electrical Specifications

Average Mutual Capacitance at 1000 Hz

Total Number of Pairs nF/mile nF/km

12 or less 83 ± 7 52 ± 4 Over 12 83 ± 4 52 ± 2

Conductor Minimum Insulation Max Average Attenuation Max Conductor Resistance Dielectric Strength

Size Resistance @ 68° F (20° C) Resistance @ 68°F (20° C) Unbalance DC Potential – Volts 68° F (20° C) 772 kHz Ohms Maximum Minimum gigohm/ gigohm/ Individual Cdr. to Cdr. to AWG mm mile km dB/kft dB/km mile km Ave % Pair % Cdr. Grnd.

19 0.90 1.0 1.6 3.2 10.5 45.0 28.0 1.5 5.0 4,500 10,000 22 0.64 1.0 1.6 4.5 14.8 91.0 56.6 1.5 5.0 3,600 10,000 24 0.50 1.0 1.6 5.6 18.4 144.0 89.5 1.5 5.0 3,000 10,000

Near End Crosstalk (NEXT) at 150 kHz 772 kHz

P.S.WUNEXT mean (dB) 58 47 P.S.WUNEXT worst pair (dB) 53 42

Far End Crosstalk at 150 kHz

Conductor size (AWG) 19 22 24 P.S. ELFEXT mean (dB/kft) 65 63 63 P.S. ELFEXT worst pair (dB/kft) 59 57 57

Far End Crosstalk at 772 kHz

Conductor size (AWG) 19 22 24 P.S. ELFEXT mean (dB/kft) 51 49 49 P.S. ELFEXT worst pair (dB/kft) 45 43 43

Capacitance Unbalance Pair to Pair

Pairs Maximum Individual Maximum RMS pF/kft pF/km pF/kft pF/km

12 or less 80 145 — — more than 12 80 145 25 45

Capacitance Unbalance Pair to Ground

Pairs Maximum Individual Maximum Average pF/kft pF/km pF/kft pF/km

12 or less 800 2625 — — more than 12 800 2625 175 574

*for cables of 12 pairs or less, the maximum average attenuation may be increased by 10% over the values shown.

GOPIC ®-FSF

Part Numbers and Physical Characteristics

Part # Pair Count Nominal O.D. Approx. Weight Standard Length Standard Reel Size Approx. Shipping Weight in mm lbs/kft kg/km ft m f x t x d lbs kg

19 AWG (0.90 mm) 09-026-27 6 0.55 14 150 223 5000 1525 44 x 18 x 20 820 372 09-028-27 12 0.65 17 235 350 5000 1525 46 x 25 x 20 1320 599 09-031-27 25 0.86 22 416 620 5000 1525 58 x 25 x 20 2300 1043 09-034-27 50 1.13 29 742 1105 5000 1525 72 x 36 x 39 4290 1946 09-038-27 100 1.50 38 1390 2071 2500 760 62 x 30 x 24 3750 1701 22 AWG (0.64 mm) 09-057-27 6 0.45 11 100 149 5000 1525 36 x 18 x 14 510 231 09-059-27 12 0.53 13 154 229 5000 1525 44 x 18 x 20 800 363 09-062-27 25 0.67 17 247 368 5000 1525 46 x 25 x 20 1320 599 09-065-27 50 0.85 22 419 624 5000 1525 58 x 25 x 20 2220 1007

09-069-27 100 1.13 29 752 1120 5000 1525 72 x 36 x 39 4180 1896 09-073-27 200 1.45 37 1408 2097 2500 760 62 x 30 x 24 3640 1651 09-075-27 300 1.76 45 2031 3025 1250 380 62 x 30 x 24 3720 1687 09-077-27 400 2.02 51 2651 3949 1250 380 62 x 30 x 24 3460 1569 09-081-27 600 2.40 61 3871 5766 1250 380 72 x 36 x 39 5260 2386 09-083-27 900 2.94 75 5685 8468 1250 380 96 x 40 x 48 8020 3638 09-085-27 1200 3.46 88 7477 11138 1000 305 96 x 40 x 48 8650 3924 24 AWG (0.50 mm) 09-092-27 6 0.39 10 79 118 5000 1525 30 x 18 x 12 390 177 09-094-27 12 0.44 11 116 173 5000 1525 36 x 18 x 14 570 259 09-097-27 25 0.57 14 183 273 5000 1525 44 x 18 x 20 920 417 09-100-27 50 0.73 19 293 436 5000 1525 46 x 25 x 20 1520 689 09-104-27 100 0.93 24 512 763 5000 1525 58 x 25 x 20 2620 1188 09-108-27 200 1.21 31 920 1370 5000 1525 72 x 36 x 39 4900 2223 09-110-27 300 1.42 36 1343 2001 2500 760 62 x 30 x 24 3430 1556 09-112-27 400 1.61 41 1762 2625 2500 760 72 x 36 x 39 4690 2127 09-116-27 600 2.01 51 2526 3763 1250 380 62 x 30 x 24 3250 1474 09-118-27 900 2.39 61 3693 5501 1250 380 72 x 36 x 39 4950 2245 09-120-27 1200 2.72 69 4840 7210 1000 305 72 x 36 x 39 5310 2408 09-121-27 1500 2.97 75 5986 8917 1000 305 78 x 40 x 39 6520 2960 09-124-27 1800 3.30 84 7122 10609 1000 305 84 x 40 x 42 7610 3452 09-125-27 2100 3.54 90 8241 12276 1000 305 96 x 40 x 48 9070 4114 09-126-27 2400 3.78 96 8982 13380 750 229 96 x 40 x 48 7910 3590

Standards Compliance:

ANSI/ICEA S-84-608-1994; RUS 7 CFR 1755.890 (PE-89)

CASPIC ®-FSF

Product Description

• CASPIC®-FSF cables are designed for direct burial or duct applications where protection from moisture is required. CASPIC®-FSF cables are recommended for use in high-risk areas where additional mechanical or rodent protection is required. CASPIC®-FSF may be used aerially, but must be attached to a support strand (messenger). CASPIC®-FSF cables, in 19, 22 and 24 AWG, are capable of meeting the electrical require-ments of 100 ohms, Category 3, Backbone UTP Cables as specified in TIA/EIA-568-A.

Physical Description

• CONDUCTORS: Solid annealed copper in 19, 22, 24 and 26 AWG.

• INSULATION: Conductors are dual insulated with an inner layer of foamed, natural polyolefin covered by an outer layer of solid, colored polyolefin. The conductor insulation is color coded in accordance with industry standard.

• TWISTED PAIRS: Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk and specific color combi-nations to provide pair identification.

• CORE ASSEMBLY: Cables of 25 pairs or less are assembled into a cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to assemble the core. Units are individu-ally identifiable by color coded unit binders.

• FILLING COMPOUND: The core assembly is filled with an 80° C ETPR compound, completely filling the interstices between the pairs and under the core wrap.

• CORE WRAP: A non-hygroscopic, dielectric tape is applied over the core assembly to provide protection for the core.

• SHIELDING: The dual shielding system consists of two metal tapes.

Inner: A corrugated, copolymer coated, 8-mil aluminum tape is applied directly over the core wrap. The aluminum tape does not butt or overlap at any point along the length of the cable.

Outer: A corrugated, copolymer coated, 6-mil steel tape is applied directly over the aluminum and overlaps. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.

• JACKET: A black, linear low-density polyethylene jacket is applied overall. The jacket provides a tough protective covering designed to withstand exposure to direct sunlight, atmospheric temperature changes and stresses expected in standard installations.

• JACKET MARKINGS: Information, such as manufacturer's identifi -cation, pair count, AWG, product identification and a telephone handset is printed at 2 ft. intervals on the cable jacket. Sequential footage markings are printed at alternate 2 ft. intervals.

• OPTIONAL DESIGNS: CASPIC®-FSF is available with an internal screen for use with T-Carrier systems.

• CASPIC®-FSF is available with mechanical protection.

Electrical Specifications

Average Mutual Capacitance at 1000 Hz

Total Number of Pairs nF/mile nF/km

12 or less 83 ± 7 52 ± 4 Over 12 83 ± 4 52 ± 2

Conductor Minimum Insulation Max Average Attenuation Max Conductor Resistance Dielectric Strength

Size Resistance @ 68° F (20° C) Resistance @ 68°F (20° C) Unbalance DC Potential – Volts 68° F (20° C) 772 kHz Ohms Maximum Minimum gigohm/ gigohm/ Individual Cdr. to Cdr. to AWG mm mile km dB/kft dB/km mile km Ave % Pair % Cdr. Grnd.

19 0.90 1.0 1.6 3.2 10.5 45.0 28.0 1.5 5.0 4,500 10,000 22 0.64 1.0 1.6 4.5 14.8 91.0 56.6 1.5 5.0 3,600 10,000 24 0.50 1.0 1.6 5.6 18.4 144.0 89.5 1.5 5.0 3,000 10,000 26 0.40 1.0 1.6 7.0 23.3 232.0 144.0 1.5 5.0 2,400 10,000

Near End Crosstalk (NEXT) at 150 kHz 772 kHz

P.S.WUNEXT mean (dB) 58 47 P.S.WUNEXT worst pair (dB) 53 42

Far End Crosstalk at 150 kHz

Conductor size (AWG) 19 22 24 26 P.S. ELFEXT mean (dB/kft) 65 63 63 61 P.S. ELFEXT worst pair (dB/kft) 59 57 57 57

Far End Crosstalk at 772 kHz

Conductor size (AWG) 19 22 24 26 P.S. ELFEXT mean (dB/kft) 51 49 49 47 P.S. ELFEXT worst pair (dB/kft) 45 43 43 43

Capacitance Unbalance Pair to Pair

Pairs Maximum Individual Maximum RMS pF/kft pF/km pF/kft pF/km

12 or less 80 145 — — more than 12 80 145 25 45

Capacitance Unbalance Pair to Ground

Pairs Maximum Individual Maximum Average pF/kft pF/km pF/kft…