RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_4.pdf

PDF 308 KB Posted

Attached to
Multiple Award Construction Contract (MACC), Ramstein AB, Germany Federal contract opportunity
Solicitation number
FA5613-14-R-0016
Issued by
Department of the Air Force Materiel Command Installation and Mission Support Center Installation Contracting Agency

About this file

RFP Atch 1 Annex 30e AF Comm Standards Part 4

View the file

Other files for this federal contract opportunity

Other files attached to Multiple Award Construction Contract (MACC), Ramstein AB, Germany, newest first.
File Type Posted
FA5613-14-R-0016-0003-Seed_Project_SOW-26Nov14.pdf PDF
FA5613-14-R-0016-0003.pdf PDF
Q A_Set__4.pdf PDF
FA5613-14-R-0016-0002-Seed_Project_SOW-13Nov14.pdf PDF
FA5613-14-R-0016-0002.pdf PDF
Questions_and_Answers_Set__3.pdf PDF
Questions_and_Answers_Set_2.pdf PDF
Questions_and_Answers_Set_2.pdf PDF
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg12.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg11.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg10.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg7.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg6.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg5.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg4.DWG DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Drawings_pg3.DWG DWG drawing
FA5613-14-R-0016-0001.pdf PDF
Pre-proposal_Conference_Slides_and_Site_Visit.pdf PDF
RFP_14-R-0016-Atch2a-Seed_Project_Floor_Plan_pg1.dwg DWG drawing
RFP_14-R-0016-Atch2a-Seed_Project_Floor_Plan_pg2.dwg DWG drawing
Q A_Set__1-20Oct2014.doc DOC document
RFP_14-R-0016-Atch1-Annex30h._AF_3064 _Progress_Schedule.pdf PDF
RFP_14-R-0016-Atch1-Annex30f._USAFE_79 _Base_Entry.pdf PDF
RFP_14-R-0016-Atch1-Annex30i._AF_3065 _Progress_Report.pdf PDF
RFP_14-R-0016-Atch1-Annex30j._AF_3000 _Material_Approval.pdf PDF
RFP_14-R-0016-Atch1-Annex30c._Spangdahlem_ACG_Section_III_7-8.pdf PDF
RFP_14-R-0016-Atch1-Annex30c._Spangdahlem_ACG_Section_II.pdf PDF
RFP_14-R-0016-Atch1-Annex30k._700_CONS_Form_66 _Matl_Submittals.doc DOC document
RFP_14-R-0016-Atch1-Annex30f._USAFE_79 _Base_Entry.xfdl XFDL file
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_1.pdf PDF
RFP_14-R-0016-Atch1-Annex30h._AF_3064 _Progress_Schedule.xfdl XFDL file
RFP_14-R-0016-Atch1-Annex30g._Blank_STP_Format.docx DOCX document
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_7.pdf PDF
RFP_14-R-0016-Atch1-Annex30i._AF_3065 _Progress_Report.xfdl XFDL file
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_6.pdf PDF
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_5.pdf PDF
RFP_14-R-0016-Atch1-Annex30j._AF_3000 _Material_Approval.xfdl XFDL file
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_3.pdf PDF
RFP_14-R-0016-Atch1-Annex30e._AF_Comm_Standards_Part_2.pdf PDF
RFP_14-R-0016-Atch3-PPID.doc DOC document
RFP_14-R-0016-Atch1-General_Req-21Aug14.doc DOC document
RFP_14-R-0016-Atch1-Annex30b._Ramstein-KMC_ACS_Edition_2008.pdf PDF
RFP_14-R-0016-Atch5-PPQ.doc DOC document
Cover-Ltr-RFP-MACC.pdf PDF
RFP_14-R-0016-Atch1-Annex30a._KMC-Spang_Base_Appearance.doc DOC document
RFP_14-R-0016-Atch2a-Seed_Project_Map Floor_Plan Drawings.pdf PDF
RFP_14-R-0016-Atch1-Annex30c._Spangdahlem_ACG_Section_I.pdf PDF
RFP_FA5613-14-R-0016.doc DOC document
RFP_14-R-0016-Atch4-SubK_Consent.doc DOC document
RFP_14-R-0016-Atch2b-Seed_Project_UFC_Band_Trng_Facilities.pdf PDF
Show all 50

Multiple Award Construction Contract (MACC), Ramstein AB, Germany has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFP-11-5REV 07/00

5-Pin Protector Modules Description

The 5-pin protector modules protect personnel and equipment from excessive voltages and currents induced on telephone lines or local ground by lightning and AC power system faults. All modules feature industry standard 5-pin bases for use in central office, remote terminal, building entrance, and customer premises applications. All modules are available with or without a heat coil to protect against sneak currents. When a sneak current is induced on the line, the heat coil responds by permanently grounding the line to prevent damage to line cards and sensitive equipment.

Carbon Protector Modules feature a carbon air gap and fail-safe mechanism that shorts to ground when a voltage exceeds its rating. A detent position disconnects the equipment side while protecting the line side (OSP cable). These modules are used where transients are not frequent or cost is a major factor.

Gas-Tube Protector Modules contain two-electrode high amperage ceramic nonradioactive gas-tube surge arresters and a fail-safe mechanism. These are used in areas where frequent transient overvoltages are a problem or where tightly controlled breakdown values are required. The gas-tube will recover repeatedly from the overvoltage, providing 30 to 40 times longer life than carbon. The detent position disconnects the equipment side while protecting the line side (OSP cables). Modules are available with a secondary vent-safe backup gap. Modules equipped with patented vent-safe gap are UL Listed (VS in catalog). If a module is specified as a JZ-type, it is a next generation new gas-type version that provides extended life and environmentally robust protection.

Solid-state Modules contain state-of-the-art diodes intended for use with sensitive equipment. They are available with 4 ohm (350mA) or 20 ohm (150 mA) heat coils. The diode is a fast semiconductor switch with operating voltage nearly independent of transient rise time.

“RXXXX” Protector Modules have either a “B” or “C” as the third character in the catalog number to denote special characteristics. Those with a B as the third character, i.e., R3B1E, have a triangular-shaped recess molded into the base to accommodate the raised structure molded into the panel of AT&T building entrance protectors.

Those modules with a C as the third character, i.e., R3C1E, have a circular-shaped hole in the shoulder of the housing to provide access for test points.

Application

These protector modules provide overvoltage and overcurrent protection for central office, remote terminal, and building entrance/customer premises applications. All protector modules provide a vent-safe gap, are fail-safe, and meet UL requirements.

Specific models are designed to meet RUS and Bellcore specifications.

Key Features

• The 5-pin protector modules protect personnel and equipment from excessive voltages and currents

• Modules feature industry standard 5-pin bases for use in central office, remote terminal, building entrance, and customer premises applications

• All modules are available with or without a heat coil to protect against sneak currents

• Carbon Protector Modules feature a carbon air gap and fail-safe mechanism that shorts to ground when a voltage exceeds its rating

• Gas-Tube Protector Modules contain two-electrode high amperage ceramic nonradioactive gas-tube surge arresters and a fail-safe mechanism

• Solid-state Modules contain state-of-the-art diodes intended for use with sensitive equipment

RFP-11-6REV 03/00

Housing Color & Size

Black, S Black w/test point, L Green, S Green w/test point, L Red, S Red w/test point, L Yellow, S Yellow w/test point, L Gray, S

5-Pin Protector Modules Ordering Information

Modules for Bell Operating Companies, No Heat Coil, Gold Plated Pins

Service

Standard Standard

Service denial Service denial

Special Special

PBX battery PBX battery

Continuity only

Standard Solid-State

(300V)

R3B1S R3C1S R3B2S R3C2S R3B3S R3C3S R3B4S R3C4S

Low Voltage Solid-State

(240V)

R3B1FS

R3C1FS

R3B2FS

R3C2FS

R3B3FS

R3C3FS

R3B4FS

R3C4FS

Gas- Tube

R3B1E R3C1E R3B2E

R3B3E R3C3E R3B4E

Carbon

R3B1A

R3B2A

R3B3A

R3B4A

R3B12A

Service

Standard Standard

Service denial Service denial

Special Special

PBX battery PBX battery

Reverse tip & ring Reverse tip & ring Continuity

Continuity only

20 Ohm

RT4B1FS

RT4C1FS

RT4B2FS

RT4C2FS

RT4B3FS

RT4C3FS

RT4B4FS

RT4C4FS

RT4B9FS

RT4C9FS

4 Ohm

R4B1S R4C1S R4B2S R4C2S R4B3S R4C3S R4B4S

R4C4S R4B9S

R4C9S

20 Ohm

RT4B1S

RT4C1S

RT4B2S

RT4C2S

RT4B3S

RT4C3S

RT4B4S

RT4C4S

RT4B9S

RT4C9S

Housing Color

Black Black w/test point Green Green w/test point Red Red w/test point Yellow Yellow with test point White

White with test point Gray Gray w/test point

Carbon

R4B1C R4C1C R4B2C R4C2C R4B3C R4C3C R4B4C R4C4C

R4B9C

R4C9C

R4B12C R4C12C

Gas- Tube

R4B1E R4C1E R4B2E

R4B3E R4C3E R4B4E

R4B9E

4 Ohm

R4B1FS

R4C1FS

R4B2FS

R4C2FS

R4B3FS

R4C3FS

R4B4FS

R4C4FS

R4B9FS

R4C9FS

Low Voltage Solid-State (240V)

Standard Solid-State (300V)

Modules for Bell Operating Companies, Long Housing, with 4 or 20 Ohm Heat Coil, Gold Plated Pins

NOTE: Size: S = short & L = long

JZ

R3B1EJZ

R3C1EJZ

R3B3EJZ

R3C3EJZ

JZ

R4B1EJZ

R4C1EJZ

R4B3EJZ

R4C3EJZ

R4B4EJZ

RFP-11-7REV 03/00

Housing Color

Black Red Orange Black Red Black Red Orange Orange Black Red Orange Black Black Red

Specification

UL, RUS, GTE

UL

RUS, GTE

RUS, GTE

RUS, GTE

RUS

RUS

RUS

UL, RUS, GTE

UL, GTE

UL, GTE

UL, RUS

UL

UL, RUS

UL

Low Voltage Solid-State

(240V)

S3ABF

S3ARF

Specification

UL, GTE

UL

UL, GTE

UL, GTE

UL, GTE

UL

Three Element

Low Voltage Solid-State

(240V)

S4ARF

S4ABF

Standard Solid-State

(300V)

S4AR

S4AB

5-Pin Protector Modules Ordering Information

Other Modules—Short Housing, No Heat Coil, Tin Plated Pins

Standard Solid-State

(300V)

S3AB*

S3AR

Three Element

3GURVS

3GB

3GR

3G

3GUVS

3GUBVS

Other Modules—Long Housing, with Heat Coil, Tin Plated Pins

Gas

G4AVS

G4ABVS

G4ARVS

Carbon

4AB

Carbon

3AB

Gas

6A20 6A20B 6A20R

6U2VS

6U2BVS

6U2RVS

Housing Color

Black Red Orange Black Red Black

* S3AB is RUS accepted in our R399 connector and available for use in connector equivalents.

NOTE 1: See the Reference Standards Chart at the end of this section.

NOTE 2: Designed to meet Bellcore TR-TSY-000070, GR-1361-CORE, GR-974-CORE, and RUS PE-80, PEG-1, PEG-3, PEG-7.

NOTE 3: All RUS modules meet the criteria in Government Publication RUS TE&CM 823.

RFP-11-8REV 03/00

www.marconi.com/osp Marconi Communications 4350 Weaver Parkway Warrenville, IL 60555 630-579-5000 Fax: 630-579-5050

© 2000 Marconi Communications Inc.

Printed in the USA. All rights reserved. Any unauthorized reproduction or transmission without the prior consent of Marconi Communications Inc. is prohibited.

5-Pin Protector Modules Configuration Guide

RBOC Catalog Numbers

Technology A = Carbon

(short housing) C = Carbon

(standard housing) E = Gas-tube S = Standard solid-state

FS = Low voltage solid-state

Housing Type 1 = Black, standard service 2 = Green, service denial 3 = Red, special service 4 = Yellow, PBX 9 = White, reverse tip & ring

10 = Gray, continuity (switch through)

Pin Type R = Gold pins

RT = Gold pins, 20 Ohm (used with solid-state)

Heat Coil 3 = Without heat coil 4 = With heat coil

Generic Internal Design B = Fail short C = Has circle-shaped hole for test points

R 4 B 1 E