FA520522R0001_Atch2_Drawings_PDF_09of12_EMCS_16Jun20.pdf
PDF 11 MB Posted
- Solicitation number
- FA520522R0001
About this file
This document provides details for a federal solicitation from the Department of the Air Force Pacific Air Forces. The solicitation, numbered FA520522R0001, is for repair work on Dormitory Building 542 at Misawa Air Base in Japan. Services required under the solicitation include general repairs to the building as well as electrical, plumbing and HVAC work. The response deadline is not provided in this attachment, though award of the contract is expected to occur in 2022. The solicitation is designated as project QKKA171042.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EM001
E M
C S
N
O T
E S
S
Y M
B O
L
A
D
B B
R E
V I A
T I O
N S
EMCS CABINET
H
HANDHOLE
ASPHALT REPAIR
CONCRETE REPAIR
AC
X
HEAT PUMP (OUTDOOR
UNIT)
CEILING CASSETTE HEAT
PUMP
HP
X
CEILING ACCESS PANEL
AC
X
CEILING HEAT PUMP
T
THERMOSTAT
K
H
E L B
I G
K R
H A
T W
1. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS AND SHALL NOTIFY THE CONTRACTING OFFICER OF
ANY DISCREPANCIES, OMISSIONS, OR CONFLICTS PRIOR TO
COMMENCING WORK.
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING
ALL DAMAGES TO EXISTING AREAS CAUSED BY THIS PROJECT TO
ORIGINAL CONDITION AS DIRECTED BY THE CONTRACTING OFFICER
/ REPRESENTATIVE AT NO ADDITIONAL COST TO THE GOVERNMENT.
3. PAINT ALL MARKS LEFT FROM REMOVAL OR RELOCATION OF
EQUIPMENT, DEVICES, AND RACEWAYS TO MATCH COLOR OF
ADJACENT SURFACES.
4. PAINT ALL EXTERIOR EXPOSED NEW EQUIPMENT INCLUDING;
CABINETS, ENCLOSURES, CONDUIT /RACEWAY, OUTLET BOXES AND
JUNCTION BOXES TO MATCH COLOR OF ADJACENT SURFACES.
5. COORDINATE SIZES OF CIRCUIT BREAKERS, WIRING, CONDUIT,
DISCONNECT SWITCHES, MOTOR STARTERS AND OTHER
ELECTRICAL ACCESSORIES WITH ACTUAL EQUIPMENT PROVIDED.
6. ELECTRICAL INSTALLATION SHALL COMPLY WITH 2017 NEC.
7. PROVIDE A SEPARATE INSULATED GREEN GROUND CONDUCTOR
SIZED IN ACCORDANCE WITH 2017 NEC TABLE 250.122 IN ALL
FEEDER AND BRANCH CIRCUIT RACEWAYS.
8. ALL WORK SHALL BE NEW UNLESS OTHERWISE INDICATED.
9. COORDINATE WORK WITH ALL TRADES AND SUB CONTRACTORS AS
APPLICABLE.
10. CONDUCTORS SHALL BE MINIMUM 3.5mm², UNLESS OTHERWISE
INDICATED.
11. CONDUCTOR SIZES SHOWN ARE THE MINIMUM ACCEPTABLE BASED
ON COPPER IN JAPANESE INDUSTRIAL STANDARD (JIS) SIZES.
12. DRAWINGS ARE SCHEMATIC ONLY. CONTRACTOR SHALL SUPPLY A
COMPLETE AND OPERABLE SYSTEM. CONTRACTOR TO DETERMINE
EXACT ROUTING OF POWER AND COMMUNICATIONS CONDUIT FOR A
COMPLETE AND OPERABLE SYSTEM. COORDINATE ROUTING WITH
MECHANICAL AND ARCHITECTURAL DISCIPLINES TO CONCEAL FROM
VIEW TO EXTENT POSSIBLE. ALL EQUIPMENT, CONDUIT, WIRING,
AND CABLES ARE TO BE INCLUDED.
13. ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED
OTHERWISE.
14. ALL EQUIPMENT SHALL BE LISTED FOR USE AT 50Hz.
15. SPECIFICATIONS ARE PART OF THE CONTRACT DOCUMENTS. SEE
SPECIFICATIONS FOR ADDITIONAL DETAILS.
16. IF EXTERIOR BUILDING NUMBERS ARE DAMAGED DURING
CONSTRUCTION, CONTRACTOR SHALL REPAINT THE NUMBER TO
MATCH EXISTING.
17. EACH BUILDING TYPE IS PROVIDED WITH DRAWINGS SHOWING
FLOOR PLANS AND ELEVATIONS. THE FLOOR PLANS DETAIL ALL
EQUIPMENT REQUIRED ON THE EXTERIOR OF THE BUILDING. THE
EQUIPMENT SHOWN ON THE ELEVATIONS ARE MEANT FOR
COORDINATION OF LARGE EQUIPMENT MOUNTED TO THE BUILDING
WALL. ELEVATIONS ARE NOT INCLUSIVE OF ALL EQUIPMENT TO BE
INSTALLED ON THE BUILDING AND THE FLOOR PLANS SHALL BE
REFERENCED FOR THIS INFORMATION.
18. PERFORMANCE AND VERIFICATION TESTING OF THE EMCS SYSTEM
IS REQUIRED PER SPECIFICATION 23 09 23.13 20. SPECIFICATION
SECTION CONTAINS REQUIREMENTS AND CHECKLISTS IN
COMPLIANCE WITH AFGM2017-32-01.
19. ALL EXTERIOR EXPOSED CONDUIT SHALL BE RIGID STEEL CONDUIT.
JIS C 8305. ALL UNDERGROUND CONDUIT SHALL BE FEP JIS C 3653.
20. ALL CONDUITS SHALL BE ATTACHED TO ANY ENCLOSURE VIA A
LISTED FITTING. DOUBLE LOCKNUTS ARE NOT ACCEPTABLE.
OUTDOOR CONDUIT CONNECTORS SHALL BE LISTED RAIN TIGHT.
CONNECTORS ON SIDE OF ENCLOSURE SHALL BE OF THREADED
HUB TYPE.
21. CONTRACTOR IS RESPONSIBLE FOR THE FIBER, CONDUIT
INSTALLATION, TERMINATION AND TESTING IN COMPLIANCE WITH
DRAWINGS AND SPECIFICATIONS.
22. CONTRACTOR RESPONSIBLE FOR REMOVAL AND REINSTALLATION
OF ALLIED TELESIS EQUIPMENT/ INFRASTRUCTURE.
23. CONTRACTOR TO PROVIDE DOCUMENTATION AND ANALYSIS OF
MECHANICAL SYSTEMS VALIDATING THAT ALL MECHANICAL
SYSTEMS OPERATE AS DESIGNED. CONTRACTOR IS RESPONSIBLE
TO NOTIFY THE BASE IMMEDIATELY IN WRITING IF DESIGNED
SYSTEMS DO NOT MEET MANUFACTURES OR SPECIFICATION
REQUIREMENTS.
24. ALL GROUNDING WIRES SHALL BE GREEN. ALL POWER WIRES SHALL
BE RED/BLACK. ALL NEUTRAL WIRES SHALL BE WHITE.
25. DASHBOARD SHALL BE FULLY INTEGRATED INTO EXISTING
SERVERS, NOT WITHSTANDING MINOR VARIATIONS IN SERVER
CONFIGURATIONS.
GENERAL PLAN NOTES:
SYMBOL LEGEND
THERMOSTAT CABLE
M-NET CABLE BETWEEN OUTDOOR UNITS
EMCS
WATER METER CABLE. TWISTED PAIR CABLE.
M-NET CABLE BETWEEN INDOOR UNITS AND
OUTDOOR UNITS
TIA-485 MODBUS CABLE
CABLE LEGEND
P
W
POWER METER
EMCS CABINET
WATER METER
R E
P A
I R
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
T
S U
B M
I T
T E
D
B
Y
U S
A
F
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
TRIP RATING
FRAME RATING
POLES
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 KCMIL
300 KCMIL
400 KCMIL
500 KCMIL
600 KCMIL
2.0
3.5
5.5
AMERICAN
WIRE GAUGE
AWG
JIS NOMINAL
SIZE (mm²)
AMPACITY
AMPS
(NOTE 1)
CONDUCTOR SIZING
NOTES:
1. REFERENCE NFPA 70, 310.15 TABLE 310.15 (B)(16)
75°, COPPER CONDUCTORS, IV(TW), THW(HIV).
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
CONDUIT AND RACEWAY
CONVERSION
AMERICAN
CONDUIT
DIAMETER
CONDUIT
METRIC
DESIGNATOR
NOTES:
1. REFERENCE NFPA 70, CHAPTER 9, TABLE 4.
JIS RSC
G16
G22
G28
G36
G42
G54
G70
G82
G92
G104
JIS EMT
E19
E25
E31
E39
E51
E63
E75
PUMP
D
DAMPER
Attachment 2 to RFP No. FA520522R0001 Drawings – EMCS dated 16 Jun 2020
EM002
M
C
H I T
E C
T U
R E
K
H E
L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
GENERAL NOTES:
1. PROVIDE PATCH CABLE BETWEEN SWITCHES AND
PATCH PANELS AS REQUIRED.
2. HVAC CONTROL SYSTEM (EMCS) SHALL BE THE
PROPERTY OF THE USAF AT THE END OF THE PROJECT,
IN ITS ENTIRETY. THIS SHALL INCLUDE (BUT NOT
LIMITED TO) ALL PROGRAMMING AND SOFTWARE
LICENSES. CONTROLS CONTRACTOR SHALL PROVIDE
THE GOVERNMENT FULL AND UNRESTRICTED ACCESS
TO ALL ASPECTS OF THE EMCS HEAD-END AND
BACK-END. THERE SHALL NOT BE ANY ASPECT OF
EMCS THAT IS INACCESSIBLE TO THE GOVERNMENT.
3. CONTRACTOR SHALL PROVIDE ALL LABOR, TOOLS,
EQUIPMENT TO COORDINATE EXISTING FRONT END
FOR EMCS (B794). CONTRACTOR MUST COORDINATE IP
ADDRESS, GRAPHICS, POP UP ALARMS WITH USAF TO
ENSURE COMPLETE FUNCTIONALITY.
4. PROVIDE THE HIGHEST LEVEL OF GRAPHICS. TOP TIER
QUALITY AND SERVES AS A SUPPLEMENT TO THE
REQUIREMENTS PROVIDED IN THE BACNET SPECIFICATIONS.
THIS WAS A PREVIOUS PROJECT COMMENT AND WANTED TO
ADD AS A LESSONS LEARNED TO PREVENT REPEAT
QUESTION.ALL EMCS PROGRAMMING SHALL MATCH
EXISTING VERSION OF THE JACE SOFTWARE AND MATCH
THE TOP TIER QUALITY LEVEL OF GRAPHICS. GRAPHICS
SHALL INDICATE THE INDOOR / OUTDOOR UNIT THAT IS
ASSIGNED TO RIGHT EW-50E (PER ZONE)
KEYNOTES
1 PROVIDE SFP PATCH CABLE BETWEEN SWITCHES AND
PATCH PANELS AS REQUIRED. REFER TO EM401.
PATCH CABLE TO BE PROVIDED UNDER THIS CONTRACT.2
DORM 542
1ST FLOOR OFFICE
FIBER PATCH
PANEL (EXISTING)
12 PORT SWITCH 'CISCO9300'
(OR COORDINATED WITH IICS
PRIOR TO PURCHASE)
BACnet
BACnet/IP (CAT6)
MEDIA
CONVERTER
B A
C n e t
P
I B
E R
EW-50E EW-50E EW-50E EW-50E
EW-50E
EW-50E EW-50E EW-50E
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
T T T T
TERMINAL BLOCK
DISTECH
ECLYPSE
DISTECH
EC-BOS 8
T
E
R
M
I
N
A
L
B
L
O
C
K
(x1) WATER METER
PULSE
DOMESTIC HOT
WATER HEATING
SYSTEM AND
STEAM METER
DI, DO, AI, AO
(x1) ELECTRIC METER:
OMRON-KM-N2-FLK
MODBUS
DORM 542
MECHANICAL ROOM
3 PANELS
UNINTERRUPTIBLE
POWER SUPPLY (UPS)
DEDICATED 120V
GFCI RECEPTACLES
TO 120V AC IN PANEL "A"
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
TO 120V AC IN PANEL "A"
M-NET (TYP)
M-NET (TYP)
M-NET (TYP)
M-NET (TYP)
M-NET (TYP)
M-NET (TYP)
M-NET (TYP)
M-NET (TYP)
M-NET (TYP)
MECH
ROOM
EMCS
EXISTING
ELECTRIC
METER
WATER
METER
1 WATER METER
CABLE
VERIFY WITH MANUFACTURER
REQUIREMENTS FOR ALL CABLE TYPES
ELECTRIC
METER CABLE
TO CS
NETWORK
PATCH
PANEL
(EXISTING)
EMCS PATCH PANEL
EMCS SWITCH
OUTDOOR
UNIT 1
INDOOR
UNIT 1
INDOOR
UNIT 2
INDOOR
UNIT 3
THERM-
OSTAT
THERM-
OSTAT
THERM-
OSTAT
SAME AS
UNIT 1
SAME AS
UNIT 1
SAME AS
UNIT 1
OUTDOOR
UNIT 2
OUTDOOR
UNIT 3
OUTDOOR
UNIT 4
NOTE:
ACTUAL NUMBER OF OUTDOOR AND INDOOR
UNITS MAY VARY. REFER TO DRAWINGS FOR
ACTUAL NUMBER OF UNITS. NO MORE THAN 50
INDOOR UNITS PER EW50-E.
SAME AS
UNIT 1
SAME AS
UNIT 1
SAME AS
UNIT 1
OUTDOOR
UNIT 5
OUTDOOR
UNIT 6
OUTDOOR
UNIT 7
SAME AS
UNIT 1
OUTDOOR
UNIT 7
TYPICAL
OF 8
ZONES
QUANTITIES
VARY PER
ZONE.
REFER TO
EM002.
ZONE 1
DHW
TANK
#1
TIC
TO DHW SUPPLY
FROM DCW SUPPLY
T
T
METER
INTEGRATOR
TIC
T
DCW SUPPLY
T
STEAM SUPPLY
COND. RETURN
T
TO DHW TANKHW RE-CIRC
T
TO DHW TANKHW RE-CIRC
MAIN
CONTROLLER
(ECLIPSE)
FACILITY
CONTROL
PROCESSOR
(DISTECH
EC-BOS 6AX)
COIN
(CEVLAN)
SWITCH
COIN
DHW
TANK
#2
TIC
T
T
TIC
T
T
STEAM SUPPLY
COND. RETURN
TO DHW SUPPLY
FROM DCW SUPPLY
DCW SUPPLY
PACKAGED AHU BACNET
COMMUNUCATION MODULE
ELECTRICAL
PANEL
STEAM METER
LOCATED IN
MECHANICAL
ROOM
METER
INTEGRATOR
WATER METER
LOCATED IN
MECHANICAL
ROOM
WATER
LEVELS
WATER
LEVELS
ELECTRICAL
METER
INTEGRATED
WITH
ELECTRICAL
BY CONTRACTOR REFER TO
EM002 FOR REQUIREMENTS
E M
O
K
A
G R
A M
SCALE:
EMCS BLOCK DIAGRAM
NONE
THERMOSTAT CABLE
M-NET CABLE BETWEEN OUTDOOR UNITS
WATER METER CABLE. TWISTED PAIR CABLE.
VERIFY CABLE WITH WATER METER VENDOR AND
EC-BOS/IO-16 VENDOR
M-NET CABLE BETWEEN INDOOR UNITS AND
OUTDOOR UNITS
TIA-485 MODBUS CABLE
SYMBOL LEGEND:
FIBER OPTIC CABLE
EM003
K
H E
L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
SCALE:
EMCS DHW BLOCK DIAGRAM
NONE
GENERAL NOTES
1. REFER TO M-403 AND M-501 FOR SEQUENCE OF OPERATIONS.
02 03 04 05 06 07 08 09 11 12 13 14
B
C
D
E
F
14'10
M A
T C
H L I N
E
W
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
ACU
HP
ACU
HP
HP
1HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
T TT T T T T
T TT T T T T
T T T
T
TO UNITS 202,
302, 402
TO UNITS 204,
304, 404
TO UNITS 206,
306, 406
TO UNITS 208,
308, 408
TO UNITS 210,
310, 410
TO UNITS 212,
312, 412
TO UNITS 214,
314, 414
TO UNITS 216,
316, 416
TO UNITS 218,
318, 418
TO LD2, LD3, LD4
TO UNITS 222,
322, 422
TO UNITS 224,
324, 424
TO UNITS 201,
301, 401
TO UNITS 203,
303 403
TO UNITS 205,
305, 405
TO UNITS 207,
307, 407
TO UNITS 209,
309, 409
TO UNITS 211,
311, 411
TO UNITS 213,
313, 413
TO UNITS 219,
319, 419
TO UNITS 221,
321, 421
TO UNITS 223,
323, 423
S2
STAIR 2
S1
STAIR 1
UNIT 124
ST1
STORAGE 1
UNIT 119
UNIT 121
UNIT 123
LD1
LAUNDRY 1
J1
JANITOR 1
C1W
CORRIDOR 1W
LG1
DAY ROOM 1
MECHANICAL RM
LINEN 1
UNIT 114
UNIT 112
UNIT 110
UNIT 108
UNIT 113
UNIT 111
UNIT 109
UNIT 107
UNIT 105
UNIT 103
UNIT 101
UNIT 102
UNIT 104
UNIT 106
RR1
RRM 1
LOBBY
FACP ROOM
C1
CORRIDOR 1
ZONE 1
EMCS
PANEL 1
S
DWH
J
ZONE 2 ZONE 3
ZONE 5 ZONE 6 ZONE 7
EMCS
PANEL 2
EMCS
PANEL 3
D
DD
DD
DD
D
D
D
D
DD
DD
DD
1 1
D
ZONE 3
D
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M A
T C
H L I N
E
ACU
ACU
ACU
ACU
ACU
ACU
ACU
1 ACU
ACU
ACU
ACU
ACU
ACU
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
T T
T T
T T
T T
T T
T T
TO UNITS 226,
326, 426
TO UNITS 228,
328, 428
TO UNITS 230,
330, 430
TO UNITS 232,
332, 432
TO UNITS 234,
334, 434
TO UNITS 236,
336, 436
TO UNITS 225,
325, 425
TO UNITS 227,
327, 427
TO UNITS 229,
329, 429
TO UNITS 231,
331, 431
TO UNITS 233,
333, 433
TO UNITS 235,
335 435
S3
STAIR 3
UNIT 130
UNIT 128
UNIT 126
UNIT 136
UNIT 135
UNIT 134
UNIT 133
UNIT 125
UNIT 127
UNIT 129
UNIT 132
UNIT 131
C1E
CORRIDOR 1E
ZONE 3 ZONE 4
ZONE 7 ZONE 8
D
1 1
D
D
1 1
D
D
D
D
D
D
D
D
D
EM101
E L E
C T
R I C
A
N
F
I R
O
M C
S
K
H
E L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
SCALE:
ELECTRICAL PLAN - FIRST FLOOR EMCS
1:100
0 700030001000
PLAN
NORTH
GENERAL NOTES
KEYNOTES
MOTORIZED DAMPER. REFER TO MECHANICAL DRAWINGS
FOR EXACT LOCATION. WIRE TO AUX CONTACT ON ACU FOR
HARD-WIRE INTERLOCK.
1. ALL CONDUIT TO BE ROUTED ABOVE CEILING, AND BELOW
STRUCTURAL BEAMS. NO CORE DRILLING OF STRUCTURAL
BEAMS PERMITTED.
2. ALL EXTERIOR WIRING TO BE IN WATER TIGHT CONDUIT.
3. ALL CONNECTIONS TO INDOOR AND OUTDOOR UNITS SHALL
HAVE A MECHANICAL CONNECTOR. LOOSE WIRING FROM END
OF CONDUIT TO UNIT SHALL NOT BE PERMITTED.
4. REFRIGERATION AND ELECTRICAL RACEWAYS ON EXTERIOR
OF FACILITY SHALL HAVE WEATHER RESISTANT CALKING LINED
ON BOTH SIDES OF THE RACEWAY AND COMPLETELY AROUND
ALL JUNCTION BOXES.
EXISTING FIBER SPLICE BOX. ROUTE NEW FIBER TO NEW
EMCS PANELS IN MECHANICAL ROOM. REFER TO EM002,
AND EM504 FOR MORE INFORMATION.
02 03 04 05 06 07 08 09 11 12 13 14
B
C
D
E
F
14'10
M A
T C
H L I N
E
T TT T T T T T T
T
T TT T T T T T
T
T T
FROM 102
TO 302
FROM 103
TO 303
FROM 105
TO 305
FROM 107
TO 307
FROM 109
TO 309
FROM 211
TO 311
FROM 113
TO 313
FROM 119
TO 319
FROM 121
TO 321
FROM 123
TO 323
FROM 104
TO 304
FROM 106
TO 306
FROM 108
TO 308
FROM 110
TO 310
FROM 112
TO 312
FROM 114
TO 314
FROM 116
TO 316
FROM LD1
TO 318
FROM LG1
TO LG3
FROM 101
TO 301
FROM HP1
TO 318
FROM HP1
TO UNIT 322
FROM UNIT 124
TO UNIT 324
S2
STAIR 2
S1
STAIR 1
UNIT 223
UNIT 221
UNIT 224
UNIT 222
UNIT 219
UNIT 218
ST2
STORAGE 2
C2W
CORRIDOR 2W
LG2
LOUNGE 2
LD2
LAUNDRY 2
UNIT 216
UNIT 214
UNIT 212
UNIT 210
UNIT 208
UNIT 206
UNIT 204
UNIT 202
UNIT 201
UNIT 203
UNIT 205
UNIT 207
UNIT 209
UNIT 211
UNIT 213
J2
JANITOR 2
C2
CORRIDOR 2
ZONE 2
ZONE 1 ZONE 2 ZONE 3
ZONE 5 ZONE 6 ZONE 7
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M A
T C
H L I N
E
T T T T T T
T T T T T T
FROM UNIT 126
TO UNIT 326
FROM UNIT 128
TO UNIT 328
FROM UNIT 130
TO UNIT 330
FROM UNIT 132
TO UNIT 332
FROM UNIT 134
TO UNIT 334
FROM UNIT 136
TO UNIT 336
FROM 125
TO 325
FROM 127
TO 327
FROM 129
TO 329
FROM 123
TO 323
FROM 133
TO 333
FROM 135
TO 335
STAIR 3
UNIT 233UNIT 231UNIT 229UNIT 227UNIT 225
UNIT 232UNIT 230UNIT 228UNIT 226 UNIT 236UNIT 234
UNIT 235
CORRIDOR 2E
ZONE 3 ZONE 4
ZONE 7 ZONE 8
D
1 1
D
D
1 1
D
D
D
D
D
D
D
D
D
EM102
E L E
C T
R I C
A L
P
L A
N
S
E C
O N
D
F
L O
C
S
K
H
E L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
SCALE:
ELECTRICAL PLAN - SECOND FLOOR EMCS
1:100
0 700030001000
PLAN
NORTH
GENERAL NOTES
KEYNOTES
MOTORIZED DAMPER. REFER TO MECHANICAL DRAWINGS
FOR EXACT LOCATION. WIRE TO AUX CONTACT ON ACU FOR
HARD-WIRE INTERLOCK.
1. ALL CONDUIT TO BE ROUTED ABOVE CEILING, AND BELOW
STRUCTURAL BEAMS. NO CORE DRILLING OF STRUCTURAL BEAMS
PERMITTED.
02 03 04 05 06 07 08 09 11 12 13 14
B
C
D
E
F
14'10
M A
T C
H L
I N
E
T TT T T T T T T
T
T TT T T T T T
T
T T
FROM 202
TO 402
FROM 204
TO 404
FROM 202
TO 402
FROM 208
TO 408
FROM 210
TO 410
FROM 212
TO 412
FROM 214
TO 414
FROM 216
TO 416
FROM 218
TO 418
FROM 222
TO 422
FROM 224
TO 424
FROM LD2
TO LD4
FROM 201
TO 401
FROM 203
TO 403
FROM 205
TO 405
FROM 207
TO 407
FROM 211
TO 411
FROM 213
TO 413
FROM 219
TO 419
FROM 221
TO 421
FROM 223
TO 423
FROM 209
TO 409
S2
STAIR 2
S1
STAIR 1
UNIT 318
UNIT 319
UNIT 321
UNIT 323
UNIT 324
UNIT 322
LG3
LOUNGE 3
ST3
STORAGE 3
C3W
CORRIDOR 3W
LD3
LAUNDRY 3
UNIT 316
UNIT 314
UNIT 312
UNIT 310
UNIT 308
UNIT 306
UNIT 304
UNIT 302
UNIT 301
UNIT 303
UNIT 305
UNIT 307
UNIT 309
UNIT 311
UNIT 313
J3
JANITOR 3
C3
CORRIDOR 3
FROM LG1
TO LG3
ZONE 1 ZONE 2 ZONE 3
ZONE 5 ZONE 6 ZONE 7
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M A
T C
H L I N
E
T T T T T T
T T T T T T
FROM 226
TO 426
FROM 228
TO 428
FROM 230
TO 430
FROM 232
TO 432
FROM 234
TO 434
FROM 236
TO 436
FROM 225
TO 425
FROM 225
TO 427
FROM 229
TO 429
FROM 231
TO 431
FROM 233
TO 433
FROM 235
TO 435
S3
STAIR 3
UNIT 333
UNIT 332
UNIT 330
UNIT 331
UNIT 325
UNIT 327
UNIT 329
UNIT 328
UNIT 326
UNIT 334
UNIT 335
UNIT 336
C3E
CORRIDOR 3E
ZONE 7 ZONE 8
D
1 1
D
D
1 1
D
D
D
D
D
D
D
D
D
EM103
E L E
C T
R I C
A L
P
L A
N
T
H I R
D
F
L O
C
S
K
H
E L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
SCALE:
ELECTRICAL PLAN - THIRD FLOOR EMCS
1:100
0 700030001000
PLAN
NORTH
GENERAL NOTES
KEYNOTES
MOTORIZED DAMPER. REFER TO MECHANICAL DRAWINGS
FOR EXACT LOCATION. WIRE TO AUX CONTACT ON ACU FOR
HARD-WIRE INTERLOCK.
1. ALL CONDUIT TO BE ROUTED ABOVE CEILING, AND BELOW
02 03 04 05 06 07 08 09 11 12 13 14
B
C
D
E
F
14'10
M A
T C
H L I N
E
T TT T T T T T T
T
T TT T T T T T
T
T T
S2
STAIR 2
S1
STAIR 1
LG4
DAY ROOM 4
UNIT 418
UNIT 419
UNIT 423
ST4
STORAGE 4
UNIT 422
UNIT 424
UNIT 416
UNIT 414
UNIT 412
UNIT 410
UNIT 408
UNIT 406
UNIT 404
UNIT 402
UNIT 401
UNIT 403
UNIT 405
UNIT 407
UNIT 409
UNIT 411
UNIT 413
LD4
LAUNDRY 4
J4
JANITOR 4
UNIT 421
C4
CORRIDOR 4
C4W
CORRIDOR 4W
RR4
RRM 4
FROM 302
FROM 304
FROM 306
FROM 308 FROM 310
FROM 312
FROM 314
FROM 316
FROM 318 FROM 322
FROM 324
FROM LD3
FROM 201
TO 401
FROM 203
TO 403
FROM 205
TO 405
FROM 207
TO 407
FROM 211
TO 411
FROM 213
TO 413
FROM 219
TO 419
FROM 221
TO 421
FROM 223
TO 423
FROM 209
TO 409
FROM LG1
TO LG3
ZONE 1 ZONE 2 ZONE 3
ZONE 5 ZONE 6 ZONE 7
D
D
D
D
D
D
D
D
D
D
D
D
1 1
D
D
D
D
D
D
D
D
D
D
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M A
T C
H L I N
E
T T T T T T
T T T T T T
S3
STAIR 3
UNIT 425
UNIT 434
UNIT 426
UNIT 428
UNIT 430
UNIT 432
UNIT 427
UNIT 429
UNIT 431
UNIT 433
UNIT 435
C4E
CORRIDOR 4E
UNIT 436
FROM 326 FROM 328
FROM 330
FROM 332
FROM 334
FROM 336
FROM 325
FROM 327 FROM 329
FROM 331
FROM 333
FROM 335
ZONE 3 ZONE 4
ZONE 7 ZONE 8
D
1 1
D
D
1 1
D
D
D
D
D
D
D
D
D
EM104
E L
E C
T R
I C
A L
P
L A
N
F
O U
R T
H
F
L O
C
S
K
H
E L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
SCALE:
ELECTRICAL PLAN - FOURTH FLOOR EMCS
1:100
0 700030001000
PLAN
NORTH
GENERAL NOTES
KEYNOTES
MOTORIZED DAMPER. REFER TO MECHANICAL DRAWINGS
FOR EXACT LOCATION. WIRE TO AUX CONTACT ON ACU FOR
HARD-WIRE INTERLOCK.
1. ALL CONDUIT TO BE ROUTED ABOVE CEILING, AND BELOW
FLOOR 1
FLOOR 2
TO WALL
12400
01 02 03 04 05 06 07 08 09 11 12 13 14
FLOOR 3
FLOOR 4
14'
GL
-500
M A
T C
H L I N
E
FLOOR 1
FLOOR 2
TO WALL
12400
14 15 16 17 18 19 20
FLOOR 3
FLOOR 4
14'
GL
-500
EMCS HANDHOLE
(TYP)
EMCS PULLBOX
GRADE
SCALE:
EMCS EXTERIOR ELEVATION - SOUTH
1:100
0 700030001000
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
EM201
E M
X T
E R
I O
R
E
L E
V A
T I O
N
S
O U
T H
K
H
E L B
I G
K R
H A
T W
SCALE:
EMCS EXTERIOR ELEVATION - SOUTH
1:100
0 700030001000
SCALE:
EMCS TYPICAL UNDERGROUND DISTRIBUTION
1:100
0 700030001000
FLOOR 1
FLOOR 2
TO WALL
12400
01020304050607080911121314
FLOOR 3
FLOOR 4
14'
GL
-500
M A
T C
H L I N
E
FLOOR 1
FLOOR 2
TO WALL
12400
01020304050607080911121314
FLOOR 3
FLOOR 4
14'
GL
-500
M A
T C
H L I N
E
FLOOR 1
FLOOR 2
TO WALL
12400
14151617181920
FLOOR 3
FLOOR 4
14'
GL
-500
M A
T C
H L I N
E
SCALE:
EMCS EXTERIOR ELEVATION - NORTH
1:100
0 700030001000
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
EM202
E M
X T
E R
I O
R
E
L E
V A
T I O
N
N
O R
T H
K
H
E L B
I G
K R
H A
T W
EM501
O
I N
S
T
SCALE:
POINTS LIST
NONE
SCALE:
ELECTRIC METER POINTS LIST
NONE
K
H
E L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
GENERAL NOTES:
1. PROVIDE PATCH CABLE BETWEEN SWITCHES AND
PATCH PANELS AS REQUIRED.
2. HVAC CONTROL SYSTEM (EMCS) SHALL BE THE
PROPERTY OF THE USAF AT THE END OF THE PROJECT,
IN ITS ENTIRETY. THIS SHALL INCLUDE (BUT NOT
LIMITED TO) ALL PROGRAMMING AND SOFTWARE
LICENSES. CONTROLS CONTRACTOR SHALL PROVIDE
THE GOVERNMENT FULL AND UNRESTRICTED ACCESS
TO ALL ASPECTS OF THE EMCS HEAD-END AND
BACK-END. THERE SHALL NOT BE ANY ASPECT OF
EMCS THAT IS INACCESSIBLE TO THE GOVERNMENT.
3. CONTRACTOR SHALL PROVIDE ALL LABOR, TOOLS,
EQUIPMENT TO COORDINATE EXISTING FRONT END
FOR EMCS (B794). CONTRACTOR MUST COORDINATE IP
ADDRESS, GRAPHICS, POP UP ALARMS WITH USAF TO
ENSURE COMPLETE FUNCTIONALITY.
4. CONTRACTOR TO ASSUME ALL POINTS ARE
REPRESENTED GRAPHICALLY. THIS INCLUDES
ELECTRICAL (POWER), METERS, AND MECHANICAL
SYSTEMS.
5. CONTRACTOR TO PROVIDE DOCUMENTATION AND
ANALYSIS OF THE MECHANICAL SYSTEMS OPERATE AS
DESIGNED. CONTRACTOR IS RESPONSIBLE TO NOTIFY
THE BASE IMMEDIATELY IN WRITING IF DESIGNED
SYSTEMS DO NOT MEET MANUFACTURES OR
SPECIFICATION REQUIREMENTS.
SCALE:
DWH POINTS LIST
NONE
B S
-VGV
EW-50J
ECLIPSE
CONTROLLER
W
M1 M2 MS
M1 M2MS
TB3
TB5
A B
M1 M2 MS
M1 M2MS
TB
TBTB
EM502
E M
T
A I L S
SCALE:
MECHANICAL EQUIPMENT WIRING DIAGRAM
NONE
SYMBOL LEGEND:
TIA-485 MODBUS CABLE
WATER METER CABLE. TWISTED PAIR CABLE.
VERIFY CABLE WITH WATER METER VENDOR AND
EC-BOS/IO-16 VENDOR
SCALE:
TYPICAL OUTDOOR UNIT
NONE
SCALE:
TYPICAL INDOOR UNIT
NONE
K
H
E L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
KEYNOTES
COMMUNICATION CABLE. PROVIDE COMMUNICATION
WIRING BETWEEN EMCS, OUTDOOR HEAT PUMPS AND
INDOOR UNITS. 1PR SHIELDED 1.25mm² (#16 AWG) IN
SEPARATE CONDUIT FROM POWER. VERIFY CABLE WITH
MANUFACTURERS REQUIREMENTS.
OUTDOOR UNIT
INDOOR UNIT
THERMOSTAT CABLE
THERMOSTAT (SEE MECHANICAL SPECIFICATIONS)
ELECTRIC METER OMRON KM-N2-FLK
WATER METER
SYSTEM CONTROLLER EW-50J TYPICAL OF 4
EMCS PANEL
TIA-485 MODBUS CABLE
(1) TIA-45-485 MODBUS CABLE TO WATER METER
OUTDOOR AIR MOTORIZED DAMPER
PANEL 1
PANEL 2 PANEL 3
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 8
ZONE 7
ZONE 6
ZONE 5
6 (TYP)
(TYP)
87 8
14 1414
21 21
PANEL FRONT (TYP)
(TYP)
(TYP)
EM503
E M
T
A I L S
SCALE:
TYPICAL EMCS CABINET
NONE
K
H
E L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
KEYNOTES
NEW EMCS ENCLOSURE. PROVIDE IP 44 STAINLESS STEEL
CABINET 700mm WIDE X 1,200mm HIGH X 250mm DEEP MINIMUM
WITH WOOD BACK BOARD. (PANASONIC BPS711220V WITH
LOCK AND KEY. LOCK TYPE SHALL BE TAKIGEN TAK70).
PROVIDE ON INSIDE DOOR OF CABINET. PROVIDE LAMINATED
LINE DIAGRAM OF INTERIOR WIRING AND CONDUITS OF
CABINET. PAINT ENCLOSURE TO MATCH BASE CUSTOM
STANDARD COLOR.
PROVIDE MEDIA CONVERTER WITH POWER SUPPLY. PROVIDE
CATEGORY 5E CABLE BETWEEN MEDIA CONVERTER AND 12
PORT ETHERNET SWITCH.
PROVIDE 12 STRAND SINGLE MODE FIBER OPTIC PATCH CABLE
BETWEEN FIBER PATCH PANEL LOCATED IN 1ST FLOOR OFFICE
OF DORM 542 AND MEDIA CONVERTER. TERMINATE (2)
STRANDS ONTO MEDIA CONVERTER.
CENTRAL CONTROLLER (MITSUBISHI EW-50E). PROVIDE WITH
INDIVIDUAL POWER SUPPLY AND BREAKER.
65mm SQUARE PVC WIREWAY MINIMUM.
PROVIDE M-NET CABLE BETWEEN EW-50E AND TERMINAL
STRIP. TYPICAL ALL.
STAINLESS STEEL STRUT CONDUIT SUPPORT
LISTED RIGID STEEL CONDUIT TO HEATPUMPS,
NEW 24 SPACE TERMINAL STRIP. NUMBER ALL SPACES 1-24.
LABEL ALL WIRING ENTERING ENCLOSURE WITH REVERSE
NUMBERING METHOD. PROVIDE TERMINAL WIRE JACKET.
DEDICATED 120V, 20A CIRCUIT FROM NEW PANEL "A".
PROVIDE TWO 125V, 20A NEMA5-20R, WEATHER RESISTANT,
GFCI RECEPTACLE, SURFACE MOUNTED INSIDE ENCLOSURE.
CIRCUIT TO PANEL "A" REFER TO ELECTRICAL DRAWINGS FOR
MORE INFORMATION.
PROVIDE (2) 3.5mm² & (1) 3.5mm² GROUND IN 28MM RIGID STEEL
CONDUIT.
NEW GROUND BUS BONDED TO ENCLOSURE AND ELECTRICAL
PANEL "A". MUST BE 10 OHMS OR LESS.
DRAIN AND PRESSURE RELIEF - STAINLESS STEEL (HOFFMANN
H20MIT OR EQUAL).
ECLIPSE CONTROLLER WITH ECY-16DI AND ECY PC-24 POWER
SUPPLY AND INDIVIDUAL CIRCUIT BREAKER.
CATEGORY 5E PATCH CABLE/WEATHERPROOF RJ45.
WATER METER CABLE
ELECTRIC METER CABLE. OMRON KM-N2FLKUL
EC-BOS 8, PROVIDE INDIVIDUAL CIRCUIT BREAKER.
UNINTERRUPTIBLE POWER SUPPLY (UPS) WITH SURGE
PROTECTION AND 2 HOUR STANDBY POWER.
SURGE PROTECTIVE DEVICE FOR POWER SUPPLY
PROVIDE HVAC SYSTEM COMM CABLE 1RP SHIELDED 2.1MM IN
28MM CONDUIT BETWEEN CONTROLLER HEAT PUMP AND
ACU'S. REFER TO EM002 FOR QUANTITIES. REFER TO
EM101-EM104 FOR LOCATIONS.
A-464-L1-1 HANDLE AND LOCK FOR EMCS PANEL BOARD.
MATERIAL: A-464-L1/ALUMINUM ALLOY (ADC)
FINISH: A-464-L1-SATELLITE CHROME PLATE (MACr) (MZCr)
KEY NUMBER: TAK70 NO. 7070 COORDINATE WITH 35CES
PROVIDE (2) FANS ON EXTERIOR OF EMCS PANELS. PROVIDE
WITH DROUGHT HOLE AND FAN FILTER.
PROVIDE BACNET CABLE BETWEEN NETWORK SWITCH AND
EW-50E. TYPICAL.
UPS
ETHERNET SWITCH
MEDIA CONVERTER
EC-BOS
EM504
E M
T
A I L S
SCALE:
SPLICE BOX
NONE
K
H
E L B
I G
K R
H A
T W
R E
P A
R
M
B
M I S
A W
A
A
S
E
J A
P A
N
Q
K K
A
F A
F
J U
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
P A
U L
V
A N
D E
N B
E R
G
GENERAL NOTES:
1. EXISTING FIBER PATCH PANEL LOCATED IN DORM 542
OFFICE. PANEL IS EXISTING TO REMAIN, SHOWN AS
REFERENCE ONLY.
SCALE:
UPS WIRING DIAGRAM
NONE
| EM001-EM001 |
| EM001-EM001 |
| EM002-EM003 (2) |
| EM002-EM003 (2) |
| EM003-EM002 |
| EM003-EM002 |
| EM101. 102, 103, 104-EM101 |
| EM101. 102, 103, 104-EM101 |
| EM101. 102, 103, 104-EM102 |
| EM101. 102, 103, 104-EM102 |
| EM101. 102, 103, 104-EM103 |
| EM101. 102, 103, 104-EM103 |
| EM101. 102, 103, 104-EM104 |
| EM101. 102, 103, 104-EM104 |
| EM201-M-201 |
| EM201-M-201 |
| EM202-M-202 |
| EM202-M-202 |
| EM501-em501 |
| EM501-em501 |
| EM502-EM502 |
| EM502-EM502 |
| EM503-EM503 |
| EM503-EM503 |
| EM503-EM504 |
| EM503-EM504 |
File details come from the government source that posted it. Updated .