FA520520R0006_Atch2_Drawings_PDF1of12_General.PDF
PDF 2 MB Posted
- Attached to
- Project No. 1058046, Repair Military Family Housing (MFH), Tower 116, Misawa Air Base, Japan
- Solicitation number
- FA520520R0006
About this file
This document package includes final design drawings and specifications for the repair of Military Family Housing Tower 116 at Misawa Air Base in Japan. The project scope involves interior demolition and hazardous material abatement, structural and architectural improvements, civil site work, new finishes and windows/doors, and renovated HVAC, electrical, plumbing, telecommunications, and fire alarm/mass notification systems. Specific work items include repairing concrete cracks, replacing guard railing posts and door panels, and sealing exterior joints. Hazardous material testing and abatement removal is also included. The solicitation was issued by the Department of the Air Force Pacific Air Forces for Project No. 1058046. Design and construction must comply with International Building Code, National Electrical Code, and other codes and standards.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAIN GATE
LEVITOW GATEPROJECT AREA
FALCON DRIVE
APPLE GATE
HAUL ROUTE
FALCON DRIVE
HAUL ROUTE
MISAWA AB
FALCON GATE
CONTRACTING DATE
CEO DATE
COMMUNICATION DATE
SFS DATE
FW AT/FP DATE
CE ENVIRONMENTAL DATE
SAFETY OFFICER DATE
BIO ENVIRONMENTAL DATE
FIRE DEPARTMENT DATE
REFERENCE NO.
DEPARTMENT OF THE AIR FORCE
PACIFIC AIR FORCES
HEADQUARTERS FIFTH AIR FORCE
BASE CIVIL ENGINEER
MISAWA AIR BASE
MISAWA JAPAN
REVISIONS
SYM. DESCRIPTION DATE APPROVAL
DESIGNED BY:
DRAWN BY:
TRACED BY:
CHECKED BY:
PROJECT NO. 1058046 (QKKA184018)
Project Title: REPAIR FAMILY HOUSING
B116 (TOWER)
MISAWA AB, JAPAN.
APPROVED BY: DATE:
BASE CIVIL ENGINEER
APPROVED BY: DATE:
USING AGENCY
SCALE:
DRAWING NUMBER
SHEET
SEQ. NO.
OTIE
OTIE
TTW
G-001
FINAL DESIGN DRAWINGS
PROJECT
1058046 (QKKA184018)
MISAWA AB, JAPAN
FINAL DESIGN 1/24/2020
VICINITY MAP
OSAKA
TOKYO
SAPPORO
HIROSHIMA
NAGASAKI
NOT TO SCALE
MISAWA
PROJECT LOCATION
LOCATION MAP
NOT TO SCALE
KEY PLAN
NOT TO SCALE
Prime Consultant:
Civil:
Structural:
Mechanical & Plumbing:
CONTACT: TIMOTHY WENDT, PE
EMAIL: TWENDT@OTIE.COM
OTIE - ONEIDA TOTAL INTEGRATED ENTERPRISES
CONTACT: JOHN THOUSAND, PE
TEL: 608-243-6473
EMAIL: JTHOUSAND@OTIE.COM
OTIE - ONEIDA TOTAL INTEGRATED ENTERPRISES
2555 PACKERLAND DRIVE
GREEN BAY, WI 54313
CONTACT: CHAD ALLEN, PE
TEL: 920-884-3967
EMAIL: CALLEN@OTIE.COM
Electrical:
OTIE - ONEIDA TOTAL INTEGRATED ENTERPRISES
CONTACT: CARLOS SANTIAGO
TEL: 619-230-1712 EXT 27
EMAIL: CSANTIAGO@OTIE.COM
2247 SAN DIEGO AVENUE, SUITE 238
SAN DIEGO, CA 92110
OTIE - ONEIDA TOTAL INTEGRATED ENTERPRISES
1033 N. MAYFAIR ROAD SUITE 200
MILWAUKEE, WI 53226
TEL: 608-241-6725
1033 N. MAYFAIR ROAD SUITE 200
MILWAUKEE, WI 53226
OTIE - RS&H JOINT VENTURE
Architectural:
RIM ARCHITECTS
851 FORT STREET, SUITE 200
HONOLULU, HI 96813
CONTACT: JOHN VANN
TEL: 808-550-0844
EMAIL: JVANN@RIMARCHITECTS.COM
Hazardous Materials Abatement:
HAWAI'I INTERNATIONAL ENVIRONMENTAL SERVICES, INC.
CONTACT: WILLIAM RANDALL
EMAIL: KANKYO123@AOL.COM
70 KIHAPAI STREET
KAILUA, HI 96734TEL: 808-263-4787
DESIGN TEAM:
CONTACT: ANDREW WALTHER, PE
TEL: 414-607-6762
EMAIL: AWALTHER@OTIE.COM
OF 2951
Telecommunications:
RS&H
10748 DEERWOOD PARK BOULEVARD SOUTH
JACKSONVILLE, FL 32256
CONTACT: STEPHEN CONWAY, PE, RCDD
TEL: 904-256-2713
EMAIL: STEPHEN.CONWAY@RSANDH.COM
Fire Protection:
RS&H
CONTACT: SCOTT LEOPOLD, PE
TEL: 904-256-2273
EMAIL: SCOTT.LEOPOLD@RSANDH.COM
10748 DEERWOOD PARK BOULEVARD SOUTH
JACKSONVILLE, FL 32256
5100 EASTPARK BOULEVARD SUITE 300
MADISON, WI 53718
REPAIR FAMILY HOUSING
B116 (TOWER)
1392090220U Text Box Attachment 2 to RFP No. FA520520R0006
R E
P A
I
F
A M
I L
Y
H
O U
S I N
G
B
T
O W
E R
M I S
A W
A
A
B
J
A P
A N
Q
K K
A
F A
F
J A
N U
A R
Y
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
C T
N
O
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
L
G
I N
E E
R
C E
N T
E R
O T
S
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L W
A U
K E
E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
T I M
O T
H Y
W
N
D T
SHEET OF 295
T
W
E N
D T
K L
N T
T W
G-002
I N
D E
X
O
F
D
R A
W I N
P A
A M
I L
Y
H
O U
S I N
B
T
O W
E R
M I S
A W
A
A
B
J
A P
A N
Q
K K
A
F A
F
J A
N U
A R
Y
SHEET
IDENTIFICATION
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S O
L I C
I T
A T
I O
N
N
O
D A
T E
C O
N T
R A
S U
B M
I T
T E
D
B
Y
U S
A
R
C E
C I V
L
G
I N
E E
R
C E
N T
E R
O T
H
J O
I N
T
V
E N
T U
R E
N
M
A Y
F A
A
D
S
U I T
E
M I L W
A U
K E
E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R I P
T I O
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
T I M
O T
H Y
W
N
D T
SHEET OF 295
T
W
E N
D T
K L
N T
T W
G-003
1. CONTRACT DOCUMENTS CONSIST OF THE COMBINATION OF DRAWINGS AND SPECIFICATIONS. CONTRACTOR IS
RESPONSIBLE FOR ALL REQUIREMENTS CONTAINED THEREIN. SPECIFICATIONS AND DRAWINGS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL; PERFORMANCE BY THE CONTRACTOR
SHALL BE REQUIRED ONLY TO THE EXTENT CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABLY INFERABLE
FROM THEM AS BEING NECESSARY TO PRODUCE THE INTENDED RESULTS. VARYING LEVEL OF DETAIL BETWEEN
DRAWINGS AND SPECIFICATION, OR AMONGST PLANS, ELEVATIONS, SECTIONS, DETAILS AND SCHEDULES, DOES NOT
CONSTITUTE OMISSION OF INFORMATION, NOR DOES IT RELIEVE THE CONTRACTOR FROM OBLIGATION TO CONTRACT
DOCUMENTS.
2. INFORMATION INDICATED ON THESE DRAWINGS HAS BEEN OBTAINED FROM A LIMITED AMOUNT OF FIELD INVESTIGATION
AND AVAILABLE SOURCES AT THE TIME THE DRAWINGS WERE PREPARED. GENERAL CONTRACTOR SHALL VERIFY ALL
EXISTING CONDITIONS AND DIMENSIONS AT THE JOB SITE. CONTRACTOR SHALL NOTIFY THE ARCHITECT & TECHNICAL
REPRESENTATIVE OF THE CONTRACTING OFFICER OF ANY DISCREPANCIES, OMISSIONS, AND CONFLICTS BEFORE
COMMENCING WORK.
3. THESE DRAWINGS ARE SUPPLIED TO THE GENERAL CONTRACTOR AND OTHERS FOR THEIR USE ON THIS SPECIFIC
PROJECT. ALL COPIES OF THESE DRAWINGS SHALL REMAIN THE PROPERTY OF THE GOVERNMENT & SHALL NOT BE
REUSED OR REPRODUCED WITHOUT PERMISSION OF THE CONTRACTING OFFICER.
4. THE ORGANIZATION OF THESE DRAWINGS IS NOT INTENDED TO CONTROL THE DIVISION OF WORK AMONG THE
SUB-CONTRACTORS. THE DIVISION OF WORK SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
5. GENERAL CONTRACTOR SHALL MAINTAIN OR PROVIDE ACCESS TO CONCEALED SPACES WITHIN THE EXISTING BUILDING
PER INTERNATIONAL BUILDING CODE (IBC) 2015 EDITION.
6. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGES TO EXISTING AREAS CAUSED BY THIS
PROJECT TO ORIGINAL CONDITION AS DIRECTED BY THE CONTRACTING OFFICER / REPRESENTATIVE.
7. SAVE ALL EXISTING TREES WITHIN AREA TO RECEIVE NEW WORK, UNLESS OTHERWISE INDICATED. COORDINATE WITH
CONTRACTING OFFICER IF THERE IS A CONFLICT. “WHERE TREE REMOVAL IS UNAVOIDABLE, NEW TREES OF A SIMILAR
TYPE MUST BE PLANTED NEAR THE LOCATION WHERE THE TREE WAS REMOVED. TREE REPLACEMENT SHALL BE ONE NEW
TREE FOR EACH TREE THAT WAS REMOVED.”
8. IN THE MILITARY FAMILY HOUSING NEIGHBORHOODS WHERE THERE ARE UNITS WHICH ARE OUTSIDE OF THE SCOPE OF
WORK THE CONTACTOR SHALL COORDINATE ANY DISRUPTION OF SERVICES CAUSED BY WORK IN THIS PROJECT. THIS
WOULD INCLUDE, BUT NOT BE LIMITED TO, DISRUPTION IN THE UTILITY LOOP FOR UNITS NOT BEING RENOVATED.
9. REFER TO HAZMAT DRAWINGS AND ASBESTOS HAZARD CONTROL ACTIVITIES SPEC SECTION FOR TESTING, REMOVAL, AND
DISPOSAL PROCEDURES REGARDING ABATEMENT WORK
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING TEMPORARY HEAT IN ALL MFH UNITS WHERE WORK IS TO BE
DONE DURING THE HEATING SEASON. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY HEATING EQUIPMENT AND
UTILITY CONNECTIONS (BUT NOT LIMITED TO) TO MAINTAIN INTERIOR SPACE TEMPERATURES IN THE MFH UNITS AT 20°C
(68°F) DURING CONSTRUCTION AND INTERRUPTION OF EXISTING HEATING EQUIPMENT.
11. THE CONTRACTOR SHALL SURVEY EXISTING CONDITIONS AT EXTERIOR WALLS PRIOR TO INSTALLATION OF MECHANICAL, ELECTRICAL, AND EMCS EQUIPMENT PRIOR TO INSTALLATION SHOP DRAWING SUBMITTAL. COORDINATE WITH BASE SUCH
THAT COR IS PRESENT FOR SURVEY OF ALL UNITS.
12. THE CONTRACTOR SHALL HAVE AN ENGLISH-SPEAKING REPRESENTATIVE AT ALL SITES AT ALL TIMES - REFER TO
SUMMARY OF WORK SPEC SECTION.
13. INTENT IS TO TO RESTRICT OUTDOOR WORK DURING WINTER (I.E. PAINT, CONCRETE, ROOF WORK, ETC). HOWEVER, THERE
IS NO WINTER EXCLUSION PERIOD. CONTRACTOR SHALL MAKE ALL NECESSARY PROVISIONS FOR WINTER WORK AT NO
ADDITIONAL COST TO GOVERNMENT.
14. HVAC CONTROL SYSTEM (EMCS) SHALL BE THE PROPERTY OF THE USAF AT THE END OF THE PROJECT, IN ITS ENTIRETY.
THIS SHALL INCLUDE (BUT NOT BE LIMITED TO) ALL PROGRAMMING AND SOFTWARE LICENSES. CONTROLS CONTRACTOR
SHALL PROVIDE THE GOVERNMENT FULL AND UNRESTRICTED ACCESS TO ALL ASPECTS OF EMCS HEAD-END AND
BACK-END. THERE SHALL NOT BE ANY ASPECT OF EMCS THAT IS INACCESSIBLE TO THE GOVERNMENT.
1. UNIFIED FACILITIES CRITERIA (UFC)
2. AIR FORCE FAMILY HOUSING GUIDE, AUGUST 2004
3. INTERNATIONAL BUILDING CODE (IBC) 2015
4. NATIONAL ELECTRICAL CODE (NEC) 2014
5. INTERNATIONAL PLUMBING CODE 2015
6. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101-LIFE
SAFETY CODE 2006
7. INTERNATIONAL MECHANICAL CODE 2015
8. UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) 1992
9. UNIFORM FIRE CODE 2003
10. INTERNATIONAL FIRE CODE 2015
11. DEPARTMENT OF DEFENSE JAPAN ENVIRONMENTAL GOVERNING
STANDARDS OCTOBER 2001
12. JAPANESE INDUSTRIAL STANDARDS (JIS) 2010
13. INSTALLATION DEVELOPMENT & DESIGN STANDARD, MISAWA
AIR BASE
14. ARCHITECTURAL AND BASE APPEARANCE STANDARDS, MISAWA
AIR BASE JAPAN
15. IEEE C2 NATIONAL ELECTRICAL SAFETY CODE 2007
16. JAPAN ENVIRONMENTAL GOVERNING STANDARDS (JEGS) 2012
17. JAPANESE ARCHITECTURAL STANDARD SPECIFICATION FOR
REINFORCED CONCRETE WORK JASS 5 (2009)
18. JAPANESE ARCHITECTURAL STANDARD SPECIFICATION JASS 6
(2007) STRUCTURAL STEELWORK SPECIFICATION FOR BUILDING
CONSTRUCTION
PROJECT DESIGN
GUIDES, CODES AND
STANDARDS
THE CONSTRUCTION DRAWINGS ARE ORGANIZED BASED ON THE UNIT TYPES DESCRIBED ABOVE. THE BEGINNING NUMBER IN A
TYPICAL SHEET REFERENCE NO. IDENTIFIES THE UNIT TYPE. FOR EXAMPLE, SHEET "AA2-MD101" IS A MECHANICAL DEMOLITION
SHEET FOR UNIT TYPE AA2. SAME LOGIC APPLIES TO SHEETS FOR ALL OTHER DISCIPLINES. SHEETS NUMBERS. THAT DO NOT
BEGIN WITH A NUMBER ARE EITHER SITE RELATED SHEETS OR SHEETS CONTAINING COMMON DETAILS OR OTHER INFORMATION.
ORGANIZATION OF CONSTRUCTION DRAWINGS
1x-AE201
UNIT TYPE (MATRIX)
DISCIPLINE NAME
SHEET NUMBER
THE CONTRACTOR SHALL PROVIDE ALL SUPERVISION, MANAGEMENT, QUALITY CONTROL, LABOR, TOOLS, EQUIPMENT, MATERIALS, AND PERFORMANCE OF ALL WORK NECESSARY TO CONSTRUCT IMPROVEMENTS FOR THE RENOVATION OF TOWER
B116 AS DEPICTED IN THE CONTRACT DOCUMENTS TO INCLUDE:
INTERIOR DEMOLITION AND HAZARDOUS MATERIAL ABATEMENT; STRUCTURAL AND ARCHITECTURAL IMPROVEMENTS TO
SUPPORT NEW BUILDING SYSTEMS; CIVIL SITE IMPROVEMENTS TO INTEGRATE WITH EXISTING SIDEWALKS, AMENITIES AND
UTILITIES; NEW ARCHITECTURAL FINISHES, NEW WINDOWS AND DOORS, NEW INSULATION ASSEMBLIES; NEW HVAC
SYSTEMS; RENOVATE ELECTRICAL AND PLUMBING SYSTEMS; TELECOMMUNICATION SYSTEMS, ENERGY MANAGEMENT
CONTROL SYSTEMS (EMCS), AND NEW FIRE ALARMS AND MASS NOTIFICATION SYSTEMS.
ROOFTOP GUARD RAILING BASE SPALL REPAIR AT ALL LOCATIONS. INCLUDE REPLACEMENT OF 10 GUARD RAILING POSTS.
REPAIR OF 3,120M CONCRETE CRACKS PER THE CONTRACT DOCUMENTS.
REPLACEMENT OF 10 DOOR PANELS TO BE DETERMINED DURING CONSTRUCTION BY CO.
REPLACEMENT OF 3,500M EXTERIOR JOINT SEALANT PER THE CONSTRUCTION DOCUMENTS.
OBTAIN AND TEST 120 BULK SAMPLES OF MATERIALS SUSPECTED TO BE ACM, NOT PREVIOUSLY SAMPLED.
REMOVE 30 EXISTING 65mm PIPE FLANGES BY CUTTING THE PIPING ON BOTH SIDES OF THE FLANGE, REMOVING FLANGE
ASSEMBLY INTACT WITHOUT DISTURBING THE GASKET MATERIAL WHICH IS PRESUMED TO BE ACM, AND DISPOSING AS
HAZARDOUS MATERIAL.
SCOPE OF WORK
GENERAL NOTES:
G E
N E
R A
L
P
R O
J E
F O
R M
A T
I
| Project No. 1058046_Repair Tower 116_General Drawings |
| G-001 |
| G-002 |
| G-003 |
File details come from the government source that posted it. Updated .