FA520520R0006_Atch2_Drawings_PDF11of12_Life Safety.pdf
PDF 4 MB Posted
- Attached to
- Project No. 1058046, Repair Military Family Housing (MFH), Tower 116, Misawa Air Base, Japan
- Solicitation number
- FA520520R0006
About this file
This document package includes life safety drawings and a related federal contract opportunity for repair work at a military family housing tower in Japan. The drawings depict the existing nine-story tower and penthouse levels, showing means of egress, travel distances, occupancy loads, fire protection systems, and other life safety features. The federal contract opportunity is a solicitation from the Department of the Air Force Pacific Air Forces to repair Tower 116 at Misawa Air Base. The scope of work involves reconfiguring and upgrading portions of the existing fire sprinkler, fire alarm and mass notification systems, while otherwise maintaining existing life safety conditions throughout the building. The response due date and anticipated award date are not provided.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B U
IL
D
IN
G
A N
D L
IF
E
S A
F E
T Y
C O
D E
E V
A L
U A
T
IO
N
BUILDING AND LIFE SAFETY CODE EVALUATION
A. APPLICABLE CODES AND STANDARDS
· US AIR FORCE FAMILY HOUSING GUIDE (AFFHG), AUGUST 2004
· INTERNATIONAL BUILDING CODE (IBC), 2015, FOR BUILDING CONSTRUCTION ONLY
· INTERNATIONAL EXISTING BUILDING CODE (IEBC), 2015
· UFC 1-200-01 GENERAL BUILDING REQUIREMENTS, 01 FEBRUARY 2018 (CHANGE 1)
· UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS, 20 JUNE 2016 (CHANGE 1)
· UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, 10 MAY 2019 (CHANGE 3)
· UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12 DECEMBER 2018
· UFC 4-021-01 DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, 1 JANUARY 2010 (CHANGE 1)
· NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARDS AS REFERENCED BY THE ABOVE, INCLUDING
BUT NOT LIMITED TO:
·· NFPA 1 FIRE CODE, 2018
·· NFPA 70 NATIONAL ELECTRICAL CODE (NEC), 2017
·· NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2016
·· NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2016
·· NFPA 90A STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATION SYSTEMS, 2018
·· NFPA 101 LIFE SAFETY CODE, 2018
B. PROJECT SCOPE AND APPLICABILITY
THIS FACILITY WAS ORIGINALLY DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH A COMBINATION OF JAPANESE BUILDING AND FIRE SERVICE LAWS AND NFPA REQUIREMENTS IN EFFECT AT THE TIME OF ORIGINAL INSTALLATION (1992) AND IS CURRENTLY ACCEPTABLE TO THE LOCAL AUTHORITIES HAVING JURISDICTION.
UPGRADING EXISTING SYSTEMS NOT BEING OTHERWISE ALTERED OR RENOVATED TO MEET CURRENT UFC, NFPA, OR US BUILDING CODE REQUIREMENTS IS NOT WITHIN THE SCOPE OF THIS PROJECT.
PER UFC 3-600-01, 34-1.5.1, ALL NEW WORK COMPLETED AS PART OF THIS PROJECT WILL COMPLY WITH UFC 3-600-01 AND NFPA 101 REQUIREMENTS FOR NEW CONSTRUCTION. THEREFORE, THIS BUILDING AND LIFE SAFETY CODE EVALUATION IS BASED ON THE REQUIREMENTS OF UFC 3-600-01 AND NFPA 101 FOR NEW CONSTRUCTION.
AREAS IN WHICH THE BUILDING DOES NOT COMPLY WITH THESE REQUIREMENTS WILL ALSO BE NOTED.
PER IEBC 401.2.1, BUILDING MATERIALS ALREADY IN USE IN A BUILDING IN COMPLIANCE WITH REQUIREMENTS OR APPROVALS IN EFFECT AT THE TIME OF THEIR ERECTION OR INSTALLATION SHALL BE PERMITTED TO REMAIN IN
USE UNLESS DETERMINED BY THE BUILDING OFFICIAL TO BE UNSAFE.
C. CLASSIFICATION OF OCCUPANCY
RESIDENTIAL (R2, APARTMENT) IBC SECTION 310
RESIDENTIAL (APARTMENT) NFPA 101, 6.1.8.1.5, CHAPTERS 30/31
STORAGE (S-1) & ASSEMBLY (A-3) AREAS ACCESSORY TO MAIN OCCUPANCY (IBC 303.4 AND 311.2)
D. CONSTRUCTION TYPE
TYPE I-B, NON-COMBUSTIBLE IBC CHAPTER 6
E. ALLOWABLE BUILDING AREA
MAXIMUM ALLOWABLE AREA UNLIMITED (IBC, TABLE 506.2)
ACTUAL AREA (PER STORY) 1630 SQ. M (17,545 SQ. FT.) GROUND FLOOR
1614 SQ. M (17,373 SQ. FT.) UPPER FLOORS
BUILDING AREA IS IN COMPLIANCE
F. ALLOWABLE BUILDING HEIGHT
MAXIMUM ALLOWABLE HEIGHT 55 M (180 FT.) / 12 STORIES (IBC, TABLES 504.3 AND .4)
(SPRINKLERED BUILDING)
ACTUAL HEIGHT 38 M (125 FT.) / 9 STORIES W/2-STORY PENTHOUSE
BUILDING HEIGHT IS IN COMPLIANCE
G. BUILDING SEPARATION AND EXPOSURE PROTECTION
MINIMUM BUILDING SEPARATION DISTANCE OF 30 FT. (9.1 M) TO AN ASSUMED PROPERTY LINE IS REQUIRED SO THAT EXTERIOR WALLS DO NOT REQUIRE A FIRE RESISTANCE RATING (IBC, TABLE 602). ALL BUILDING EXTERIOR WALLS MEET THIS MINIMUM SEPARATION DISTANCE AND ARE NOT REQUIRED TO BE FIRE RESISTANCE RATED.
EXTERIOR WALLS ARE PERMITTED TO HAVE UNLIMITED UNPROTECTED OPENING AREA (IBC, TABLE 705.8).
H. FIRE / SMOKE RATING REQUIREMENTS FOR BUILDING ELEMENTS
BUILDING ELEMENT RATING (IBC, TABLE 601)
PRIMARY STRUCTURAL FRAME 2-HR
EXTERIOR BEARING WALLS NA (TABLE 602)
INTERIOR BEARING WALLS 2-HR
FLOOR CONSTRUCTION 2-HR
ROOF CONSTRUCTION 1-HR
NOTES:
1. EXISTING WALL/ROOF CONSTRUCTION MEETS ABOVE NOTED MINIMUM FIRE RESISTANCE RATINGS.
2. EXISTING CONCRETE ENCASED COLUMNS AND BEAMS ARE ASSUMED TO HAVE MINIMUM 40mm CONCRETE
COVER PER APPLICABLE JAPANESE ARCHITECTURAL STANDARD SPECIFICATION (JASS) FOR REINFORCED CONCRETE WORK, JASS 5, AND MEET ABOVE NOTED MINIMUM FIRE RESISTANCE RATINGS FOR PRIMARY
STRUCTURAL FRAME.
3. EXISTING CONCRETE FLOOR CONSTRUCTION DOES NOT MEET ABOVE NOTED MINIMUM FIRE RESISTANCE
RATING, BUT DOES MEET MINIMUM FIRE SEPARATION RESISTANCE RATING NOTED BELOW.
I. FIRE / SMOKE RATED SEPARATIONS AND PARTITIONS
ELEMENT RATING OPENING PROTECTIVE
EXIT STAIRS / SHAFTS 1-HR *1-HR (NFPA 101, 7.1.3.2.1.3.B)
TRASH COLLECTION ROOMS 1-HR AND SPRINKLERS *45-MINUTE (NFPA 101, TABLE 30.3.2.1.1)
MECHANICAL / ELECTRICAL ROOMS1-HR *45-MINUTE (NFPA 101, TABLE 30.3.2.1.1)
CORRIDORS .5-HR *20-MINUTE (NFPA 101, 30.3.6.1.2)
SLEEPING UNIT SEPARATION .5-HR 20-MINUTE (NFPA 101, 30.3.7.2 & 8.3.3.2.2)
FIRE PUMP ROOM 2-HR *1.5-HR (NFPA 20, 4.13.1.1.1)
*NOTES: JAPANESE FIRE DOORS RATED 20/60 MINUTE PERMITTED PER UFC 3-600-01, APPENDIX G.
EXISTING FIRE PUMP ROOM TO REMAIN, BUILDING MECHANICAL ROOM 150.
J. INTERIOR FINISHES
· WALL/CEILING FINISHES SHALL BE CLASS A IN EXIT ENCLOSURES, CLASS A OR B IN LOBBIES AND CORRIDORS, AND CLASS A, B OR C IN ALL OTHER AREAS (NFPA 101, 30.3.3.2).
· FLOOR FINISHES SHALL BE MINIMUM CLASS II IN EXIT ENCLOSURES, EXIT ACCESS CORRIDORS, AND OTHER SPACES NOT SEPARATED FROM THEM BY MINIMUM 1/2-HOUR FIRE RESISTIVE CONSTRUCTION (NFPA 101, 30.3.3.3).
· CARPET AND CARPET-LIKE MATERIALS SHALL COMPLY WITH ASTM D2859 (NFPA 101, 10.2.7.1). FLOOR FINISHES OTHER THAN CARPET SHALL HAVE MINIMUM CRITICAL RADIANT FLUX OF 0.10 W/SQ. CM (NFPA 101, 10.2.7.2).
· THERMAL AND ACOUSTICAL INSULATION SHALL HAVE FLAME SPREAD RATING NOT HIGHER THAN 75 AND SMOKE DEVELOPMENT RATING NOT HIGHER THAN 150, EXCEPT AS PERMITTED BY UFC 3-600-01, PARA 8-3.2
(UFC 3-600-01, PARA. 8-3.1.1).
K. FIRE / SMOKE DAMPERS
FIRE DAMPERS, WHERE REQUIRED BY NFPA 90A, WILL BE DYNAMIC TYPE, RATED FOR 3000 FT./MIN. OR GREATER AND WILL BE PROVIDED WHERE REQUIRED IN DUCTS PASSING THROUGH FIRE RATED WALLS, PARTITIONS AND FLOORS. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. THERE ARE NO SMOKE DAMPER
REQUIREMENTS PER NFPA 90A.
L. FIRE EXTINGUISHING SYSTEMS
THE FACILITY IS PROVIDED WITH EXISTING WET-PIPE AUTOMATIC FIRE SPRINKLERS THROUGHOUT THE BUILDING. A SUBMERSIBLE FIRE PUMP IS PROVIDED IN THE BUILDING MECHANICAL ROOM TO MEET THE PRESSURE
REQUIREMENTS OF THE EXISTING FIRE SPRINKLER SYSTEMS.
THE FACILITY IS ALSO PROVIDED WITH EXISTING CLASS I MANUAL DRY STANDPIPE SYSTEMS IN THREE OF THE SIX TOTAL EXIT STAIR ENCLOSURES. THE STANDPIPE PRESSURE REQUIREMENTS WILL BE MET BY THE RESPONDING
FIRE DEPARTMENT PUMPER TRUCK THROUGH THE BUILDING FIRE DEPARTMENT CONNECTIONS.
THE EXISTING CLASS II AUTOMATIC WET STANDPIPE SYSTEMS HAVE BEEN TAKEN OUT OF SERVICE AND ABANDONED IN PLACE, ALL HOSE VALVE CABINETS HAVE BEEN SEALED SHUT. THESE WILL BE PARTIALLY
DEMOLISHED AS SHOWN ON THE DRAWINGS.
PORTABLE FIRE EXTINGUISHERS ARE PROVIDED IN EACH DWELLING UNIT.
EXISTING FIRE SPRINKLER AND CLASS I STANDPIPE SYSTEMS ARE NOT IN COMPLIANCE WITH CURRENT UFC 3-600-01 AND NFPA 101 REQUIREMENTS FOR NEW CONSTRUCTION, BUT ARE CURRENTLY ACCEPTABLE TO THE AUTHORITIES HAVING JURISDICTION. THESE WILL BE EXISTING TO REMAIN AND WILL NOT BE UPGRADED TO MEET
CURRENT CODES AND STANDARDS.
EXISTING SPRINKLERS WILL BE RECONFIGURED IN SEVERAL AREAS WHERE NEW ROOMS ARE CONSTRUCTED;
MODIFICATIONS WILL USE EXISTING BRANCH LINES TO REMAIN.
M. WATER SUPPLY ANALYSIS
WATER SUPPLY FLOW TESTING WAS CONDUCTED BY BASE PERSONNEL AND WITNESSED BY THE A/E FIRE
PROTECTION ENGINEER ON 16 MARCH 2018.
TEST HYDRANT: HYDRANT D-42
STATIC PRESSURE 56 PSI (386.1 KPA)
RESIDUAL PRESSURE 46 PSI (317.2 KPA)
FLOW HYDRANTS: MEASURED FLOW: 1062 GPM (4020 LPM) EACH AT HYDRANTS AT D-40, D-41, D-43
944 GPM (3573 LPM) AT HYDRANT D-44
4130 GPM (15,633 LPM) TOTAL FLOW
FLOW AT 20 PSI (138 KPA) 8254 GPM (31,245 LPM)
SYSTEM DEMAND: DESIGN AREA = 280 SQ. M (3000 SQ. FT.)
(EXISTING SPRINKLERS)DESIGN DENSITY = 4.07 LPM / SQ. M (0.10 GPM / SQ. FT.)
REQUIRED FLOW = 1140 LPM (300 GPM)
REQUIRED DURATION = 45 MINUTES
EXISTING STORAGE = 68,000 L (17,960 GAL)
EXISTING FIRE PUMP = 1140 LPM @ 82 M TOTAL HEAD (300 GPM @ 117 PSI)
BASED ON THESE FLOW TEST RESULTS, THE WATER SUPPLY IS ADEQUATE TO MEET THE BUILDING FIRE SPRINKLER
DEMAND THROUGH THE EXISTING BUILDING STORAGE TANK AND FIRE PUMP.
N. FIRE ALARM / MASS NOTIFICATION SYSTEMS
THE FACILITY WILL BE PROVIDED WITH A NEW COMBINED, ADDRESSABLE FIRE ALARM AND MASS NOTIFICATION SYSTEM (FA/MNS). THIS NEW FA/MNS WILL BE CONNECTED TO EXISTING BASEWIDE REPORTING SYSTEM. SMOKE DETECTORS WITH SOUNDER BASE WILL BE PROVIDED IN ALL DWELLING UNITS IN ACCORDANCE WITH UFC AND
NFPA REQUIREMENTS.
THE FACILITY IS ALSO PROVIDED WITH A GIANT VOICE MASS COMMUNICATION SYSTEM CONSISTING OF SEVERAL LOUDSPEAKERS LOCATED IN THE PUBLIC AREAS ON EACH FLOOR. THIS SYSTEM WILL BE EXISTING TO REMAIN.
THERE IS NO REQUIREMENT FOR THIS SYSTEM TO COMMUNICATE WITH OR BE CONNECTED TO THE NEW FA/MNS.
O. DUCT SMOKE DETECTORS
DUCT SMOKE DETECTORS WILL BE INSTALLED DOWNSTREAM OF THE FILTERS AND UPSTREAM OF ANY BRANCH CONNECTIONS IN SUPPLY SYSTEMS HAVING CAPACITY GREATER THAN 2000 CFM. SEE FIRE PROTECTION
DRAWINGS FOR ADDITIONAL INFORMATION.
P. FIRE DEPARTMENT VEHICLE ACCESS
THE FACILITY IS PROVIDED WITH EXISTING PAVED, ALL-WEATHER GROUND ACCESS STARTING FROM THE ROAD AND TERMINATING NOT MORE THAN 10 M (33 FT.) FROM AN EXTERIOR DOOR ACCESSIBLE TO THE FIRE
DEPARTMENT. ALL FIRE DEPARTMENT VEHICLE ACCESS WAYS WILL BE EXISTING TO REMAIN.
Q. FIRE HYDRANTS
FIRE HYDRANTS IN THE VICINITY OF THE BUILDING ARE EXISTING TO REMAIN AND ARE INSTALLED IN ACCORDANCE WITH UFC 3-600-01. THE BUILDING FIRE DEPARTMENT CONNECTION IS PROVIDED WITHIN 46 M (150 FT.) OF THE
NEAREST FIRE HYDRANT.
R. EMERGENCY GENERATOR
THE EXISTING EMERGENCY STANDBY POWER SYSTEMS ARE INSTALLED IN ACCORDANCE WITH A COMBINATION OF JAPANESE INDUSTRY STANDARDS, MILITARY HANDBOOK AND NFPA REQUIREMENTS IN EFFECT AT THE TIME OF ORIGINAL CONSTRUCTION (1992). THIS SYSTEM WILL NOT BE MODIFIED OR UPGRADED TO MEET CURRENT UFC AND
NFPA REQUIREMENTS AS PART OF THIS PROJECT.
S. ELEVATOR
NO CHANGES OR MODIFICATIONS TO THE EXISTING ELEVATOR CONTROLS ARE INCLUDED IN THE SCOPE OF THIS PROJECT. ALL EXISTING ELEVATOR CONTROLS AND FIRE ALARM INTERFACES WILL BE RECONNECTED TO THE NEW
FIRE ALARM SYSTEM.
T. EMERGENCY COMMAND CENTER
SINCE THE RENOVATION COST OF THIS PROJECT IS LESS THAN 50% OF THE PROJECTED REPLACEMENT VALUE OF THE FACILITY, THE EMERGENCY COMMAND CENTER REQUIRED FOR NEW HIGH-RISE CONSTRUCTION IS NOT
REQUIRED AND WILL NOT BE PROVIDED IN THIS PROJECT.
U. SMOKEPROOF ENCLOSURES
SINCE THE RENOVATION COST OF THIS PROJECT IS LESS THAN 50% OF THE PROJECTED REPLACEMENT VALUE OF THE FACILITY, SMOKEPROOF ENCLOSURES REQUIRED FOR NEW HIGH-RISE CONSTRUCTION ARE NOT REQUIRED AND WILL NOT BE PROVIDED. EXISTING MANUAL SMOKE EXHAUST SYSTEM HAS NOT BEEN MAINTAINED AND WILL
BE DEMOLISHED AS IT IS NO LONGER REQUIRED.
A. OCCUPANT LOAD
OCCUPANT LOAD FACTORS:
APARTMENT BUILDINGS 18.6 SQ. M (200 SQ. FT.) GROSS / PERSON
ASSEMBLY (CONCENTRATED USE)0.65 SQ. M (7 SQ. FT.) NET /PERSON
GROUND FLOOR OCCUPANCY: 151 SQ. M * 1 PERSON / 0.65 SQ. M= 232 PERSONS
1479 SQ. M * 1 PERSON / 18.6 SQ. M = 79 PERSONS
311 PERSONS
UPPER FLOOR OCCUPANCY: 1614 SQ. M * 1 PERSON / 18.6 SQ. M = 87 PERSONS
B. CAPACITY OF MEANS OF EGRESS
1120 mm MINIMUM CORRIDOR WIDTH REQUIRED (NFPA 101, 30.2.3.3), 1150 mm MINIMUM CORRIDOR WIDTH PROVIDED 1120 mm MINIMUM STAIR WIDTH REQUIRED (NFPA 101, 7.2.2.2.1.2), 1186 mm MINIMUM STAIR WIDTH PROVIDED
MINIMUM EXIT CAPACITY REQUIRED AT GROUND FLOOR
5.0 mm / PERSON FOR LEVEL MEANS OF EGRESS * 311 PERSONS= 1500 mm REQUIRED 4 DOUBLE DOORS @ 1710 mm CLEAR OPENING EACH = 6840 mm PROVIDED
EXIT CAPACITY IS ADEQUATE FROM THE GROUND FLOOR
MINIMUM EXIT CAPACITY REQUIRED AT UPPER FLOORS
5.0 mm / PERSON FOR LEVEL MEANS OF EGRESS * 87 PERSONS= 435 mm REQUIRED
7.6 mm / PERSON FOR STAIRS AND RAMPS * 87 PERSONS = 661 mm REQUIRED
EACH DWELLING UNIT OCCUPANT HAS ACCESS TO 2 CENTRAL EXIT STAIRS AND 1 EXTERIOR EXIT STAIR:
2 CENTRAL STAIR DOORS @ 868 mm CLEAR OPENING EACH = 1736 mm 1 EXTERIOR STAIR DOOR @ 818 mm CLEAR OPENING = 818 mm TOTAL EGRESS DOOR WIDTH PROVIDED = 2554 mm
2554 mm TOTAL DOOR WIDTH * 1 PERSON / 5 mm = 510 PERSON CAPACITY THRU EXIT DOORS
EXIT DOOR CAPACITY IS ADEQUATE FROM ALL UPPER FLOORS
2 CENTRAL STAIRS @ 1236 mm CLEAR OPENING EACH = 2472 mm 1 EXTERIOR STAIR @ 1186 mm CLEAR OPENING = 1186mm TOTAL STAIR WIDTH PROVIDED = 3658 mm
3658 mm TOTAL STAIR WIDTH * 1 PERSON / 7.6 mm = 481 PERSON CAPACITY THRU EXIT STAIRS
EXIT STAIR CAPACITY IS ADEQUATE FROM ALL UPPER FLOORS
EXIT STAIRS ARE THE LIMITING FACTOR IN EGRESS
C. NUMBER OF MEANS OF EGRESS
MINIMUM NUMBER OF EXITS REQUIRED= 2 PER STORY
ACTUAL NUMBER OF EXITS PROVIDED= 3 FROM EACH UPPER STORY (ACCESSIBLE FROM EACH APARTMENT)
5 FROM GROUND FLOOR (ACCESSIBLE FROM EACH APARTMENT)
NUMBER OF MEANS OF EGRESS IS ADEQUATE AND IN COMPLIANCE
D. ARRANGEMENT OF MEANS OF EGRESS
EXITS ARE PROVIDED ON ALL 4 SIDES OF THE BUILDING ON THE GROUND FLOOR.
EXITS ARE ADEQUATELY AND REMOTELY LOCATED.
E. TRAVEL DISTANCE TO EXITS
TRAVEL DISTANCE
MAXIMUM DISTANCE PERMITTED WITHIN DWELLING UNIT = 38 M (125 FT.) (101, 30.2.6.2)
ACTUAL TRAVEL DISTANCE = 17 M (56 FT.)
MAXIMUM DISTANCE PERMITTED FROM DWELLING UNIT TO EXIT = 61 M (200 FT.) (101, 30.2.6.3.2)
ACTUAL TRAVEL DISTANCE = 19 M (63 FT.)
MAXIMUM DISTANCE PERMITTED FROM OTHER THAN DWELLING UNIT= 76 M (250 FT.) (101, 30.2.6.4)
ACTUAL TRAVEL DISTANCE = 27 M (89 FT.)
MAXIMUM TRAVEL DISTANCE FROM GENERAL INDUSTRIAL SPACE= 76 M (250 FT.) (NFPA 101, 40.2.6.1)
ACTUAL TRAVEL DISTANCE (ROOF MECHANICAL ROOM) = 27 M (88 FT.)
COMMON PATH OF TRAVEL
MAXIMUM COMMON PATH OF TRAVEL PERMITTED = 15 M (50 FT.) (101, 30.2.5.3.2)
(OUTSIDE DWELLING UNIT)
ACTUAL COMMON PATH OF TRAVEL(GARBAGE ROOM) = 13 M (43 FT.)
MAXIMUM COMMON PATH OF TRAVEL, GENERAL INDUSTRIAL SPACE= 30 M (100 FT.) (NFPA 101, 40.2.5.1)
ACTUAL COMMON PATH OF TRAVEL(ROOF MECHANICAL ROOM) = 27 M (88 FT.)
DEAD END CORRIDOR
MAXIMUM DEAD END CORRIDOR PERMITTED = 15 M (50 FT.) (101, 30.2.5.4.2)
ACTUAL DEAD END CORRIDOR PROVIDED = 3 M (10 FT)
TRAVEL DISTANCE IS IN COMPLIANCE
F. DISCHARGE FROM EXITS
ALL EXITS DISCHARGE DIRECTLY TO PUBLIC WAY.
EXIT DISCHARGE IS IN COMPLIANCE.
G. ILLUMINATION OF MEANS OF EGRESS
ILLUMINATION OF THE MEANS OF EGRESS WILL BE CONTINUOUSLY PROVIDED. ILLUMINATION WILL BE A MINIMUM OF 10 FT-CANDLES AT THE WALKING SURFACE IN STAIRS AND 1 FT-CANDLE IN ALL OTHER EGRESS PATHWAYS. SEE ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION.
H. EMERGENCY LIGHTING
EMERGENCY LIGHTING WILL BE PROVIDED FOR A MINIMUM OF 1-1/2 HOURS IN THE EVENT OF FAILURE OF NORMAL LIGHTING.
SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
I. MARKING OF MEANS OF EGRESS
EXITS WILL BE PROVIDED WITH APPROVED SIGNAGE READILY VISIBLE FROM ANY DIRECTION OF EXIT APPROACH. SEE
ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
LIFE SAFETY EGRESS EVALUATION
S
L E
O P
O L
D
S V
L S
W D
LP001
R E
P A
IR
F
A M
IL
Y
H O
U S
IN
G
B
(T O
W E
R
M
IS
A W
A A
B , J
A P
A N
Q K
K A
F A
-1
-F -0
JA
N
U A
R Y
SHEET
IDENTIFICATION
D E
S
IG
N E
D B
Y
D W
N B
Y
C K
D B
Y
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
C O
N T
R A
C T
N O
S
U B
M
IT
T E
D B
Y
U .S
A
IR
F
O R
C E
C
IV
IL
E
N G
IN
E
E R
C E
N T
E R
O T
IE
R
S
H J
O
IN
T V
E N
T U
R E
N
M
A Y
F A
IR
R
O A
D S
U
IT
E
M
IL
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
T
IM
O T
H Y
W E
N D
T
SHEET OF 295
LeopoldS Snapshot
Wx
W x
Wx
Wx
Wx
W x
W x
Wx
W x
W x
W x
W x
W x
W x
W x
B116
B178
W
EXISTING FIRE LANE
PRIMARY FIRE DEPARTMENT
BUILDING ACCESS
EXISTING DRY CLASS I
STANDPIPE FDC
EXISTING DRY CLASS I
STANDPIPE FDC
EXISTING SPRINKLER
SYSTEM FDC
EXISTING FIRE PUMP
ROOM ACCESS
BUILDING SEPARATION TO ASSUMED
PROPERTY LINE FOR LIFE SAFETY
EVALUATION PURPOSES
EXISTING FIRE LANE
EXISTING WATER
PIPING
EXISTING FIRE
HYDRANT
EXISTING REMOVABLE
BOLLARDS
EXISTING REMOVABLE
BOLLARDS
EXISTING FIRE HYDRANT
L
IF
E S
A F
E T
Y S
IT
E
P L
A N
SCALE:
LIFE SAFETY SITE PLAN
1:1501 0 3000 6000 12000
S
L E
O P
O L
D
S V
L S
W D
LP100
R E
P A
IR
F
A M
IL
Y
H O
U S
IN
G
B
(T O
W E
R
M
IS
A W
A A
B , J
A P
A N
Q K
K A
F A
-1
-F -0
JA
N
U A
R Y
SHEET
IDENTIFICATION
D E
S
IG
N E
D B
Y
D W
N B
Y
C K
D B
Y
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
C O
N T
R A
C T
N O
S
U B
M
IT
T E
D B
Y
U .S
A
IR
F
O R
C E
C
IV
IL
E
N G
IN
E
E R
C E
N T
E R
O T
IE
R
S
H J
O
IN
T V
E N
T U
R E
N
M
A Y
F A
IR
R
O A
D S
U
IT
E
M
IL
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
T
IM
O T
H Y
W E
N D
T
SHEET OF 295
LIFE SAFETY LEGEND
30-MINUTE FIRE RATED PARTITION
1-HR FIRE RATED PARTITION
EGRESS PATH OF TRAVEL
EGRESS EXIT
EGRESS TRAVEL STARTING DATUM
TRAVEL DISTANCE TO EXIT (mm)TD
WET PIPE SPRINKLER RISER
STANDPIPE HOSE VALVE
SPRINKLER FLOOR CONTROL VALVE ASSEMBLY
FIRE PUMP W/ELECTRIC DRIVER
FIRE DEPARTMENT CONNECTION, DRY STANDPIPE
FIRE DEPARTMENT CONNECTION, SPRINKLER
DRY STANDPIPE RISER
COMMON PATH OF TRAVEL (mm)CPT
DEAD END CORRIDOR (mm)DEC
E ELEVATOR IN NON-COMBUSTIBLE SHAFT
A
A.0
B
C
D
E
F
G
G.0
00 02 03 04 05 06 07 08
1F UNIT STO 1
1F ELEC
1F UNIT STO 2
ELEV
ELEV SHAFT
PIPE SPACE
CART RM
ST-2
STAIR 2
ST-2
STAIR 2
MULTIPURPOSE
RM
LOBBY
MP KITCHENETTEUA03
KITCHEN
UA01
ENTRY UA05
LAUNDRY
UA06
LIVING-DINING
UA17
BEDROOM 3
UA07
HALL
UA09
BATH
UA13
MST BATH
UA14
BEDROOM 2
UA10
MST BEDROOM
BALCONY
UA06
LIVING-DINING
UA14
BEDROOM 2
UA10
MASTER
BEDROOM
UA17
BEDROOM 3
UA09
BATH
UA13
MASTER BATH
UA07
HALL
UA03
KITCHEN
UA01
ENTRY
UA05
LAUNDRY
1F HALL
ENTRANCE 2
ENTRANCE 1
GARBAGE
MAIN ELEC RM
GENERATOR RM
WS-A
WING STAIR A
WS-D
WING STAIR D
WS-C
WING STAIR C
WS-B
WING STAIR B
1F STORAGE
MAIN MECH RM
1F STO
TD=15,200
TD=16,800
TD=18,100
TD=28,650
TD=26,000
CPT = 13,000
TD=15,000
CPT = 15,000
EXIT CAPACITY =
342 PERSONS
EXIT CAPACITY =
342 PERSONS
EXIT CAPACITY =
169 PERSONS (TYP)
EXIT CAPACITY =
353 PERSONS
EXIT CAPACITY = 342
PERSONS (TYP)
EXIT CAPACITY =
173 PERSONS
STAIR CAPACITY = 156
PERSONS (TYP)
EGRESS TYPICAL FOR
ALL DWELLING UNITS
TD=19,900
E
E
L
IF
E S
A F
E T
Y P
L A
N
F
IR
S T
F L
O O
R
KEYNOTES
1 EXISTING ELECTRIC FIRE SPRINKLER PUMP TO REMAIN.
2 EXISTING CLASS II STANDPIPE PUMP IS OUT OF SERVICE
AND ABANDONED IN PLACE.
SCALE:
LIFE SAFETY PLAN - FIRST FLOOR
1:1501 0 3000 6000 12000
S
L E
O P
O L
D
S V
L S
W D
LP101
R E
P A
IR
F
A M
IL
Y
H O
U S
IN
G
B
(T O
W E
R
M
IS
A W
A A
B , J
A P
A N
Q K
K A
F A
-1
-F -0
JA
N
U A
R Y
SHEET
IDENTIFICATION
D E
S
IG
N E
D B
Y
D W
N B
Y
C K
D B
Y
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
C O
N T
R A
C T
N O
S
U B
M
IT
T E
D B
Y
U .S
A
IR
F
O R
C E
C
IV
IL
E
N G
IN
E
E R
C E
N T
E R
O T
IE
R
S
H J
O
IN
T V
E N
T U
R E
N
M
A Y
F A
IR
R
O A
D S
U
IT
E
M
IL
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
T
IM
O T
H Y
W E
N D
T
SHEET OF 295
B116
B117
B
B
Y E
LLO
W
S T
O N
E D
R
B
B
B
B
B186
B
B
S H
E N
A N
D O
A H
D R
N
A
A.0
B
C
D
E
F
G
G.0
00 02 03 04 05 06 07 08
T16
TYP UNIT STO 1
T14
TYP ELEC RM
T17
TYP UNIT STO 2
T11
TYP PIPE SPACE
_ST-1
STAIR 1
_ST-2
STAIR 2
_ST-2
STAIR 2
UA03
KITCHEN
UA06
LIVING-DINING
UA17
BEDROOM 3
UA14
BEDROOM 2
UA10
MASTER
BEDROOM
UA07
HALL
UA09
BATH
UA13
MASTER BATH
UA01
ENTRY
UA05
LAUNDRY
BALCONY
UA03
KITCHEN
UA01
ENTRY UA05
LAUNDRY
UA06
LIVING-DINING
UA17
BEDROOM 3
UA07
HALL
UA09
BATH
UA13
MST BATH
UA14
BEDROOM 2
UA10
MST BEDROOM
BALCONY
UA06
LIVING-DINING
UA14
BEDROOM 2
UA10
MASTER
BEDROOM
UA17
BEDROOM 3
UA09
BATH
UA13
MASTER BATH
UA15
BR2 CLO 1
UA03
KITCHEN
UA01
ENTRY
UA05
LAUNDRY
T13
TYP HALL
T13
TYP HALL
BALCONY
T19
MECH
TD=16,800
TD=15,200
NEW MECHANICAL ROOM
AT FLOORS 2, 5 & 8 ONLY
TD=22,800
DEC=2060
STAIR CAPACITY = 156
PERSONS (TYP)
STAIR CAPACITY = 162
PERSONS (TYP)
EGRESS TYPICAL FOR
ALL DWELLING UNITS
TD=17,900
E
E
LP102
L
IF
E S
A F
E T
Y P
L A
N
T Y
P
IC
A L
F L
O O
R
-8
SCALE:
LIFE SAFETY PLAN - TYPICAL FLOOR (2-8)
1:1501 0 3000 6000 12000
S
L E
O P
O L
D
S V
L S
W D
R E
P A
IR
F
A M
IL
Y
H O
U S
IN
G
B
(T O
W E
R
M
IS
A W
A A
B , J
A P
A N
Q K
K A
F A
-1
-F -0
JA
N
U A
R Y
SHEET
IDENTIFICATION
D E
S
IG
N E
D B
Y
D W
N B
Y
C K
D B
Y
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
C O
N T
R A
C T
N O
S
U B
M
IT
T E
D B
Y
U .S
A
IR
F
O R
C E
C
IV
IL
E
N G
IN
E
E R
C E
N T
E R
O T
IE
R
S
H J
O
IN
T V
E N
T U
R E
N
M
A Y
F A
IR
R
O A
D S
U
IT
E
M
IL
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
T
IM
O T
H Y
W E
N D
T
SHEET OF 295
B116
B117
B
B
Y E
LLO
W
S T
O N
E D
R
B
B
B
B
B186
B
B
S H
E N
A N
D O
A H
D R
N
A
A.0
B
C
D
E
F
G
G.0
00 02 03 04 05 06 07 08
9F UNIT STO 1
9F ELEC
9F UNIT STO 2
ELEV
ELEV SHAFT
9F PIPE SPACE
ST-1
STAIR 1
_ST-2
STAIR 2
STAIR RM
UA03
KITCHEN
UA06
LIVING-DINING
UA17
BEDROOM 3
UA14
BEDROOM 2
UA10
MASTER
BEDROOM
UA07
HALL
UA09
BATH
UA13
MASTER BATH
UA01
ENTRY
UA05
LAUNDRY
BALCONY
UA03
KITCHEN
UA01
ENTRY UA05
LAUNDRY
UA06
LIVING-DINING
UA17
BEDROOM 3
UA07
HALL
UA09
BATH
UA13
MST BATH
UA14
BEDROOM 2
UA10
MST BEDROOM
BALCONY
UA06
LIVING-DINING
UA14
BEDROOM 2
UA10
MASTER
BEDROOM
UA17
BEDROOM 3
UA09
BATH
UA13
MASTER BATH
UA07
HALL
UA03
KITCHEN
UA01
ENTRY
UA05
LAUNDRY
9F HALL
9F HALL
TD=16,800
TD=15,200
TD=17,900
TD=22,800
DEC=2060
STAIR CAPACITY = 156
PERSONS (TYP)
STAIR CAPACITY = 162
PERSONS (TYP)
EGRESS TYPICAL FOR
ALL DWELLING UNITS
E
E
LP103
L
IF
E S
A F
E T
Y P
L A
N
N
IN
T H
F L
O O
R
SCALE:
LIFE SAFETY PLAN - NINTH FLOOR
1:1501 0 3000 6000 12000
S
L E
O P
O L
D
S V
L S
W D
R E
P A
IR
F
A M
IL
Y
H O
U S
IN
G
B
(T O
W E
R
M
IS
A W
A A
B , J
A P
A N
Q K
K A
F A
-1
-F -0
JA
N
U A
R Y
SHEET
IDENTIFICATION
D E
S
IG
N E
D B
Y
D W
N B
Y
C K
D B
Y
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
C O
N T
R A
C T
N O
S
U B
M
IT
T E
D B
Y
U .S
A
IR
F
O R
C E
C
IV
IL
E
N G
IN
E
E R
C E
N T
E R
O T
IE
R
S
H J
O
IN
T V
E N
T U
R E
N
M
A Y
F A
IR
R
O A
D S
U
IT
E
M
IL
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
T
IM
O T
H Y
W E
N D
T
SHEET OF 295
B116
B117
B
B
Y E
LLO
W
S T
O N
E D
R
B
B
B
B
B186
B
B
S H
E N
A N
D O
A H
D R
N
C
D
E
03 04 05
PH2-1
ELEV MACH RM
PH2-2
MECH TANK RM
_ST-1
STAIR 1
CPT=15,000
STAIR CAPACITY = 162
PERSONS (TYP)
03 04 05 06
R02
ROOF MECH 2
PH1-4
PH1 FAN 1
PH1-3
PH1 MECH
ELEV
ELEV SHAFT
PH1-1
PH1 LOBBY
R01
ROOF MECH 1
PH1-2
PH1-PIPE ROOM
_ST-1
STAIR 1
PH1-5
PH1 STORAGE
PH1-6
PH1 FAN 2
R03
ROOF MECH A
CPT=27,000
TD=27,000
STAIR CAPACITY = 162
PERSONS (TYP)
E
E
C
D
E
LP104
L
IF
E S
A F
E T
Y P
L A
N
P E
N T
H O
U S
E S
SCALE:
LIFE SAFETY PLAN - PENTHOUSE 1
1:1501 0 3000 6000 12000
SCALE:
LIFE SAFETY PLAN - PENTHOUSE 2
1:1502 0 3000 6000 12000
S
L E
O P
O L
D
S V
L S
W D
R E
P A
IR
F
A M
IL
Y
H O
U S
IN
G
B
(T O
W E
R
M
IS
A W
A A
B , J
A P
A N
Q K
K A
F A
-1
-F -0
JA
N
U A
R Y
SHEET
IDENTIFICATION
D E
S
IG
N E
D B
Y
D W
N B
Y
C K
D B
Y
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
C O
N T
R A
C T
N O
S
U B
M
IT
T E
D B
Y
U .S
A
IR
F
O R
C E
C
IV
IL
E
N G
IN
E
E R
C E
N T
E R
O T
IE
R
S
H J
O
IN
T V
E N
T U
R E
N
M
A Y
F A
IR
R
O A
D S
U
IT
E
M
IL
W A
U K
E E
W
I
A
B
C
D
1 2 3 4 5
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
T
IM
O T
H Y
W E
N D
T
SHEET OF 295
B116
B117
B
B
Y E
LLO
W
S T
O N
E D
R
B
B
B
B
B186
B
B
S H
E N
A N
D O
A H
D R
N
TOWER 116 KEY PLAN
| Project No. 1058046_Repair Tower 116_Life Safety Drawings |
| LP001 |
| LP100 |
| LP101 |
| LP102 |
| LP103 |
| LP104 |
File details come from the government source that posted it. Updated .