Attachment 5 Sheet 2 of 2 KAG 10-1042E E-1.pdf

PDF 182 KB Posted

Attached to
Repair Lighting for Ammo Area Federal contract opportunity
Solicitation number
FA4809-11-R-0002
Issued by
Department of the Air Force Air Combat Command

About this file

Attachment 5 Sheet 2 of 2 E-1

View the file

Other files for this federal contract opportunity

Other files attached to Repair Lighting for Ammo Area, newest first.
File Type Posted
Questions and answers 8 Feb 11.docx DOCX document
Questions and answers 4 Feb 11.docx DOCX document
Questions and Answers 1 Feb 11.docx DOCX document
Revised Drawing Sheet E-1.pdf PDF
Amendment 0001.doc DOC document
Site Visit.pdf PDF
11-R-0002.doc DOC document
Attachment 4 AF66 VKAG 10-1042E.pdf PDF
Attachment 5 Sheet 1 of 2 VKAG 10-1042E G-1.pdf PDF
Cover Sheet and Instructions.doc DOC document
Attachment 1 SPECIFICATIONS VKAG 10-1042E .doc DOC document
Attachment 7 Facility Inspection Assessment Letter.pdf PDF
Attachment 3 DOR.doc DOC document
Attachment 6 Construction Cost Estimate Breakdown.pdf PDF
Attachment 2 Wage Determination.docx DOCX document
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10350

10349

10348

L

L

L

POLE MOUNTED FLOOD &

COBRA HEAD LUMINAIRES

ON SAME POLE. THIS

LOCATION ONLY.

H

H

H H

L

L

L

L

M

M

M M

M L

H

M

M M

M

M M

M

M

M M

M M M

M M

M M M M

M M M M

E

E

E

E

E

E

E

1245 3

H

T

R

F

U

B

T

A P

P R

V D

D A

T E

I

T

S

R

O

F

U

G

D E

S C

R I P

T I O

N R

E V

F

E

H

D

C

B

P R

O J E

C T

I T

L E

D R

A W

I N

G

S

H E

E

N

A M

E

SCALE

DATE

T H

U N

I T

D

S

A

T E

S

A

R

F

O R

C

V

I L

E

N G

I N

E E

R

S

Q U

A D

R O

N

S E

Y M

O U

R

J O

H N

S O

N

A

F

R

B

S

E

N

O R

H

R

O L I N

A

SHEET

DRAWN BY

OF

PROJECT NUMBER

245 3

DRAWING NUMBER

A

678910

G

F

E

H

D

C

B

678910

C:\Users\Carlos.Alfaro\Desktop\10-1042E\VKAG 10-1042 E E-1.dwg

P A

L

G

H T

I N

G

F

O R

A M

M

E

A

E L E

C T

R I C

A L

L I G

H T

I N

G

S

I T

E

P

L A

N

24 SEPT 10

1"=60'

CEPT

E-1

VKAG 10-1042E

N

MAG. VAR. 9Á-21'W

JUN '10

GENERAL NOTES

1. THE CONTRACTOR'S MEANS AND METHODS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NFPA 70 NATIONAL

ELECTRIC CODE AND UFC 3-530-01 GUIDELINES.

2. ALL ITEMS INDICTAED TO BE REMOVED SHALL BE PROPERLY DISPOSED OFF BASE BY THE CONTRACTOR.

3. THE CONTRACTOR SHALL COORDINATE THE WORK WITH OTHER CONTRACTORS TO AVOID UNNECESSARY CONFLICTS AND

INTERFERENCE AND FOR THE FREE FLOW OF THE SCHEDULED WORK.

4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND/OR MANUFACTURER'S LITERATURE OF LUMINAIRES FOR REVIEW BY THE

CONTRACTING OFFICER.

5. CONTRACTOR SHALL PERFORM, COORDINATE, AND SCHEDULE WORK IN SUCH A MANNER TO MINIMIZE ALL ELECTRICAL OUTAGES.

6. CONTRACTOR SHALL FIELD VERIFY LOCATION, SPECIFICATION, AND OPERABILITY OF EQUIPMENT.

7. CONTRACTOR SHALL NOT DISTURB 1,000 WATT POLE MOUNTED SECURITY FLOOD LUMINAIRES DIRECTED AT FENCE LINE.

LEGEND

EXISTING 250 WATT HIGH PRESSURE SODIUM COBRA HEAD LUMINAIRE ATTACHED TO ALUMINUM POLE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-CH” COBRA HEAD FIXTURE LISTED ON

LUMINAIRE SCHEDULE. EXISTING CIRCUIT WIRING TO BE REUSED.

EXISTING 150 WATT INCANDESCENT JELLY JAR LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE.

REPLACE WITH “TYPE-DL” WALL PACK FIXTURE LISTED ON LUMINAIRE SCHEDULE. EXISTING CIRCUIT WIRING TO

BE REUSED.

EXISTING 50 WATT HIGH PRESSURE SODIUM WALL PACK LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-DL” WALL PACK FIXTURE LISTED ON LUMINAIRE SCHEDULE. EXISTING CIRCUIT

WIRING TO BE REUSED.

EXISTING 400 WATT HIGH PRESSURE SODIUM WALL PACK LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-DH” WALL PACK FIXTURE LISTED ON LUMINAIRE SCHEDULE.

EXISTING CIRCUIT WIRING TO BE REUSED.

EXISTING 70 WATT METAL HALIDE WALL PACK LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE.

REPLACE WITH “TYPE-DM” WALL PACK FIXTURE LISTED ON LUMINAIRE SCHEDULE. EXISTING CIRCUIT WIRING TO

BE REUSED.

EXISTING 150 WATT HIGH PRESSURE SODIUM CEILING MOUNTED LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-CL” CANOPY FIXTURE LISTED ON LUMINAIRE SCHEDULE. EXISTING

CIRCUIT WIRING TO BE REUSED.

EXISTING 400 WATT YOKE MOUNTED FLOOD LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE.

REPLACE WITH “TYPE-FH” FLOOD LUMINAIRE LISTED ON LUMINAIRE SCHEDULE. NEW FIXTURE IS TO REMAIN

POINTED IN SAME DIRECTION. EXISTING CIRCUIT WIRING TO BE REUSED.

EXISTING 400 WATT POLE MOUNTED FLOOD LUMINAIRE (NUMBER OF FIXTURES AS SHOWN) TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-FH” FLOOD LUMINAIRE FIXTURE LISTED ON LUMINAIRE SCHEDULE. NEW FIXTURE IS TO REMAIN POINTED IN SAME DIRECTION. EXISTING CIRCUIT WIRING

TO BE REUSED.

EXISTING 1,000 WATT POLE MOUNTED FENCELINE SECURITY FLOOD LUMINAIRES (NUMBER OF FIXTURES AS

SHOWN)TO REMAIN.

EXISTING POLE TO REMAIN

LUMINAIRE SCHEDULE

TYPE-CH: COBRA HEAD TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 150 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 13,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.

TYPE-DL: WALL PACK TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 40 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 3,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.

TYPE-DH: WALL PACK TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 120 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 10,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.

TYPE-DM: WALL PACK TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 50 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 4,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.

TYPE-CL: CANOPY TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 50 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 4,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.

TYPE-FH: FLOOD TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 200 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 18,000. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.

L