Attachment 5 Sheet 2 of 2 KAG 10-1042E E-1.pdf
PDF 182 KB Posted
- Attached to
- Repair Lighting for Ammo Area Federal contract opportunity
- Solicitation number
- FA4809-11-R-0002
About this file
Attachment 5 Sheet 2 of 2 E-1
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions and answers 8 Feb 11.docx | DOCX document | |
| Questions and answers 4 Feb 11.docx | DOCX document | |
| Questions and Answers 1 Feb 11.docx | DOCX document | |
| Revised Drawing Sheet E-1.pdf | ||
| Amendment 0001.doc | DOC document | |
| Site Visit.pdf | ||
| 11-R-0002.doc | DOC document | |
| Attachment 4 AF66 VKAG 10-1042E.pdf | ||
| Attachment 5 Sheet 1 of 2 VKAG 10-1042E G-1.pdf | ||
| Cover Sheet and Instructions.doc | DOC document | |
| Attachment 1 SPECIFICATIONS VKAG 10-1042E .doc | DOC document | |
| Attachment 7 Facility Inspection Assessment Letter.pdf | ||
| Attachment 3 DOR.doc | DOC document | |
| Attachment 6 Construction Cost Estimate Breakdown.pdf | ||
| Attachment 2 Wage Determination.docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10350
10349
10348
L
L
L
POLE MOUNTED FLOOD &
COBRA HEAD LUMINAIRES
ON SAME POLE. THIS
LOCATION ONLY.
H
H
H H
L
L
L
L
M
M
M M
M L
H
M
M M
M
M M
M
M
M M
M M M
M M
M M M M
M M M M
E
E
E
E
E
E
E
1245 3
H
T
R
F
U
B
T
A P
P R
V D
D A
T E
I
T
S
R
O
F
U
G
D E
S C
R I P
T I O
N R
E V
F
E
H
D
C
B
P R
O J E
C T
I T
L E
D R
A W
I N
G
S
H E
E
N
A M
E
SCALE
DATE
T H
U N
I T
D
S
A
T E
S
A
R
F
O R
C
V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
S E
Y M
O U
R
J O
H N
S O
N
A
F
R
B
S
E
N
O R
H
R
O L I N
A
SHEET
DRAWN BY
OF
PROJECT NUMBER
245 3
DRAWING NUMBER
A
678910
G
F
E
H
D
C
B
678910
C:\Users\Carlos.Alfaro\Desktop\10-1042E\VKAG 10-1042 E E-1.dwg
P A
L
G
H T
I N
G
F
O R
A M
M
E
A
E L E
C T
R I C
A L
L I G
H T
I N
G
S
I T
E
P
L A
N
24 SEPT 10
1"=60'
CEPT
E-1
VKAG 10-1042E
N
MAG. VAR. 9Á-21'W
JUN '10
GENERAL NOTES
1. THE CONTRACTOR'S MEANS AND METHODS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NFPA 70 NATIONAL
ELECTRIC CODE AND UFC 3-530-01 GUIDELINES.
2. ALL ITEMS INDICTAED TO BE REMOVED SHALL BE PROPERLY DISPOSED OFF BASE BY THE CONTRACTOR.
3. THE CONTRACTOR SHALL COORDINATE THE WORK WITH OTHER CONTRACTORS TO AVOID UNNECESSARY CONFLICTS AND
INTERFERENCE AND FOR THE FREE FLOW OF THE SCHEDULED WORK.
4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND/OR MANUFACTURER'S LITERATURE OF LUMINAIRES FOR REVIEW BY THE
CONTRACTING OFFICER.
5. CONTRACTOR SHALL PERFORM, COORDINATE, AND SCHEDULE WORK IN SUCH A MANNER TO MINIMIZE ALL ELECTRICAL OUTAGES.
6. CONTRACTOR SHALL FIELD VERIFY LOCATION, SPECIFICATION, AND OPERABILITY OF EQUIPMENT.
7. CONTRACTOR SHALL NOT DISTURB 1,000 WATT POLE MOUNTED SECURITY FLOOD LUMINAIRES DIRECTED AT FENCE LINE.
LEGEND
EXISTING 250 WATT HIGH PRESSURE SODIUM COBRA HEAD LUMINAIRE ATTACHED TO ALUMINUM POLE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-CH” COBRA HEAD FIXTURE LISTED ON
LUMINAIRE SCHEDULE. EXISTING CIRCUIT WIRING TO BE REUSED.
EXISTING 150 WATT INCANDESCENT JELLY JAR LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE.
REPLACE WITH “TYPE-DL” WALL PACK FIXTURE LISTED ON LUMINAIRE SCHEDULE. EXISTING CIRCUIT WIRING TO
BE REUSED.
EXISTING 50 WATT HIGH PRESSURE SODIUM WALL PACK LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-DL” WALL PACK FIXTURE LISTED ON LUMINAIRE SCHEDULE. EXISTING CIRCUIT
WIRING TO BE REUSED.
EXISTING 400 WATT HIGH PRESSURE SODIUM WALL PACK LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-DH” WALL PACK FIXTURE LISTED ON LUMINAIRE SCHEDULE.
EXISTING CIRCUIT WIRING TO BE REUSED.
EXISTING 70 WATT METAL HALIDE WALL PACK LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE.
REPLACE WITH “TYPE-DM” WALL PACK FIXTURE LISTED ON LUMINAIRE SCHEDULE. EXISTING CIRCUIT WIRING TO
BE REUSED.
EXISTING 150 WATT HIGH PRESSURE SODIUM CEILING MOUNTED LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-CL” CANOPY FIXTURE LISTED ON LUMINAIRE SCHEDULE. EXISTING
CIRCUIT WIRING TO BE REUSED.
EXISTING 400 WATT YOKE MOUNTED FLOOD LUMINAIRE TO BE REMOVED AND PROPERLY DISPOSED OFF BASE.
REPLACE WITH “TYPE-FH” FLOOD LUMINAIRE LISTED ON LUMINAIRE SCHEDULE. NEW FIXTURE IS TO REMAIN
POINTED IN SAME DIRECTION. EXISTING CIRCUIT WIRING TO BE REUSED.
EXISTING 400 WATT POLE MOUNTED FLOOD LUMINAIRE (NUMBER OF FIXTURES AS SHOWN) TO BE REMOVED AND PROPERLY DISPOSED OFF BASE. REPLACE WITH “TYPE-FH” FLOOD LUMINAIRE FIXTURE LISTED ON LUMINAIRE SCHEDULE. NEW FIXTURE IS TO REMAIN POINTED IN SAME DIRECTION. EXISTING CIRCUIT WIRING
TO BE REUSED.
EXISTING 1,000 WATT POLE MOUNTED FENCELINE SECURITY FLOOD LUMINAIRES (NUMBER OF FIXTURES AS
SHOWN)TO REMAIN.
EXISTING POLE TO REMAIN
LUMINAIRE SCHEDULE
TYPE-CH: COBRA HEAD TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 150 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 13,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.
TYPE-DL: WALL PACK TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 40 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 3,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.
TYPE-DH: WALL PACK TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 120 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 10,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.
TYPE-DM: WALL PACK TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 50 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 4,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.
TYPE-CL: CANOPY TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 50 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 4,500. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.
TYPE-FH: FLOOD TYPE INDUCTION LUMINAIRE. CORROSION RESISTANT, FULLY SEALED ENCLOSURE. WET LOCATION FOR OUTDOOR USE AND INCLUDES CORROSION RESISTANT HARDWARE. HEAT RESISTANT TEMPERED GLASS LENS. HIGH POWER FACTOR MULTI-TAP ELECTRONIC BALLAST. FIXTURE CONTROLLED VIA INTEGRAL PHOTOCELL. PROVIDE 200 WATT INDUCTION LAMP WITH MINIMUM MEAN LUMENS OF 18,000. THE INDUCTION LAMP SHALL HAVE A 3500K COLOR TEMPERATURE, AND HAVE A 100,000 HOUR RATED LIFE. LAMPS AND BALLASTS ARE LISTED AND CERTIFIED BY CE, FCC, AND UL STANDARDS.
L
H
M
File details come from the government source that posted it. Updated .