Atch-13 Sewer Line Connection Detail.pdf
PDF 107 KB Posted
- Attached to
- Family Camp RV Parking Expansion
- Solicitation number
- FA480325B001
About this file
This technical drawing details a sewer line connection specification (Detail D-3) for a construction project. The document provides a comprehensive plan and section view of how to connect a new sewer main to an existing sewer main, with specific technical requirements. Key technical specifications include:
The drawing specifies critical installation requirements such as using 6" pipe for single service connections, employing riser connections when sewer depth exceeds 7'-0", using Mission, Fernco, or flexible couplings with stainless steel bands, and maintaining a minimum 20' length with a minimum 1% slope. Installation notes emphasize compatibility of pipe connections, allow for alternate riser and bend configurations, and prohibit connections below the springline of the main sewer line. The detail is part of the Shaw Air Force Base Family Camp RV Parking Expansion project, which involves adding 14 recreational vehicle parking spaces with associated infrastructure improvements.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEWER LINE CONNECTION DETAIL D-3
NTS