This document consists of two separate product manuals: an Instruction Sheet for the ERK Series Enclosure and a User Manual for Online UPS systems (UPS-OL1500R, UPS-OL2200R, and UPS-OL3000R) manufactured by Middle Atlantic Products.
The ERK Series Enclosure instruction sheet provides safety guidelines and specifications for a UPS rack enclosure system. The enclosure is available in heights from 10 RU to 44 RU (each RU equals 1.75 inches), with a width of 22 inches and depths of 20, 25, or 28 inches. The unit has a maximum load rating of 2,500 pounds, with component weight distribution requirements: a minimum of 50 percent in the bottom third, a maximum of 25 percent each in the middle and top thirds. The enclosure is UL-listed and intended for ambient temperatures of 32°F to 140°F. Optional protective earth terminal kits are available (PET-K-RD and PET-K-FD) for rear and front door bonding. The document includes detailed grounding and bonding instructions for door installations and emphasizes qualified personnel-only installation with extensive safety warnings regarding electrical hazards, weight distribution, and caster usage.
The Online UPS User Manual covers three rackmount UPS models with capacities of 1500VA (1350W), 2200VA (1800W), and 3000VA (2700W). All models feature double-conversion online backup protection with zero transfer time, ECO Mode for energy efficiency exceeding 93 percent, configurable output voltage options (100V, 110V, 115V, 120V, 125V at ±2 percent), and sealed maintenance-free battery systems. Input specifications include 100-125Vac range at 50/60Hz with 0.99 power factor and cold start capability. The UPS-OL1500R contains three 12V/9AH batteries while the 2200R and 3000R models contain six 12V/9AH batteries with approximately 4-5 hour recharge times. All models include multi-function LCD displays with 19 types of readouts, 22 configuration settings, and 5 event logs; LED indicators for operational status; and connectivity ports including serial (RS-232), USB, relay output, and optional SNMP/HTTP network card slots. The systems support hot-swappable batteries, auto-charge and auto-restart features, overload protection with load shedding capabilities for critical and non-critical outlets, and optional expansion battery modules (UPS-OLEBPR-1 and UPS-OLEBPR-2). Rackmount installation requires 2RU of cabinet space, and the document provides comprehensive hardware installation procedures, operation instructions, maintenance protocols, and troubleshooting guidance with extensive safety precautions throughout.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
53393lni Text Box
MIDDLE ATLANTIC
ERK Series Enclosure Instruction Sheet
I-00734 Rev -
ULRC US
LISTED
WARNING: Failure to read, understand and follow the following information can result in serious personal injury, damage to the equipment or voiding of the warranty.
AVERTISSEMENT: Ne pas lire, comprendre et suivre les informations suivantes peut entraîner des blessures graves, des dommages à l'équipement ou de la nullité de la garantie.
CAUTION: To avoid an unstable condition, place heavier components at the bottom of the enclosure. When more than one component is placed in the enclosure, begin at the bottom of the enclosure and place equipment at the lowest available point, evenly distribute weight (horizontally) within the enclosure.
Component weight should be distributed as follows:
• 1/2 of the total component weight (at a minimum) placed in the bottom third of the cabinet
• 1/4 of the total component weight (at a maximum) placed in the middle third of the cabinet
• 1/4 of the total component weight (at a maximum) placed in the top third of the cabinet
ATTENTION: Pour éviter un état instable, placez composants les plus lourds au fond de l'enceinte. Lorsque plus d'un composant est placé dans la enceinte, commencer par le bas de l'enceinte et placer l'équipement à la point le plus bas disponible, de distribuer uniformément le poids (horizontalement) dans le enceinte.
Le poids des composants devrait être réparti comme suit:
• 1/2 du poids total de la composante (au minimum) placé dans le tiers inférieur de l'armoire
• 1/4 du poids total de la composante (au maximum) placé dans le tiers médian de l'armoire
• 1/4 du poids total de la composante (au maximum) placé dans le tiers supérieur de l'armoire
IMPORTANT SAFETY INSTRUCTIONS / INSTRUCTIONS IMPORTAANTES SUR LA SÉCURITÉ
DANGER HAZARDOUS VOLTAGE/DANGER HAUTE TENSION
The lightning flash with the arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
L'éclair avec le symbole de flèche dans un triangle équilatéral est destiné à alerter l'utilisateur de la présence d'une tension dangereuse non isolée dans l'enceinte du produit qui peut être d'une ampleur suffisante pour constituer un risque de choc électrique pour les personnes.
CAUTION/ATTENTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Le point d'exclamation dans un triangle équilatéral est destiné à alerter l'utilisateur de la présence d'importants instructions d’opération et de maintenance (entretien) dans la documentation accompagnant l'appareil.
SAVE ALL INSTRUCTIONS / CONSERVER CES INSTRUCTIONS
CAUTION: All installation and assembly steps must be performed by qualified personnel.
ATTENTION: Toutes installation et de montage étapes doivent être effectuées par du personnel qualifié.
CAUTION: Ensure that the floor has a structural load capacity that will support the weight of the cabinet fully loaded with equipment.
ATTENTION: Veiller à ce que le sol a une capacité de charge structurelle qui supporter le poids de le cabinet entièrement chargé avec l'équipement .
CAUTION: Some parts of the enclosure system may not be effectively bonded to the Protective Earth Terminal (PET). If these parts need to be bonded to the PET it should be done in accordance with Article 250 of the National Electrical Code.
ATTENTION: Certaines parties du système d'enceinte ne peut être efficacement liée à la Terre de protection Terminal (PET). Si ces pièces doivent être collées au PET, il devrait être fait conformément à l'article 250 du Code national de l'électricité.
CAUTION: Power cord(s), for fans or other accessories, need to be secured to ensure that they are routed away from pinch points and moving parts.
ATTENTION: Le cordon d'alimentation (s), pour les fans ou autres accessoires, doivent être fixé à veiller à ce que ils sont acheminés loin des points de pincement et des pièces mobiles.
IMPORTANT SAFETY INSTRUCTIONS / INSTRUCTIONS IMPORTAANTES SUR LA SÉCURITÉ
CAUTION: Use caution when moving the cabinets with casters installed. There is a possibility of tilting. Always move cabinet over smooth floor surfaces and a short distance only. The enclosure should only be moved by pushing on the front or rear of the cabinet. DO NOT push from the side.
ATTENTION: Soyez prudent lors du déplacement des armoires à roulettes installées. Il se agit d'un possibilité de basculement. Toujours déplacer l'armoire sur les surfaces lisses et à une courte distance seulement. L'enceinte ne doit être déplacé en poussant sur le devant ou à l'arrière de l'armoire. FAIRE PAS pousser de côté.
CAUTION: Casters (if used) are not intended to support excessive cabinet loads for extended periods of time. Please refer to caster base instruction sheet for recommended weight capacity. Always use levelers to stabilize the cabinet after locating.
ATTENTION: Roulettes (le cas échéant) ne sont pas destinés à supporter des charges excessives du Cabinet pour prolongée périodes de temps. Se il vous plaît se référer à Caster feuille d'instructions de base pour poids recommandé la capacité. Toujours utiliser niveleurs pour stabiliser l'armoire après avoir localisé .
CAUTION: Do not attempt to unload or move the enclosures alone. Make sure to have sufficient amount of personnel and equipment to safely move this product.
ATTENTION: Ne essayez pas de décharger ou déplacer les enceintes seul. Assurez-vous d'avoir quantité suffisante de personnel et de matériel pour déplacer ce produit en toute sécurité.
IMPORTANT SAFETY INSTRUCTIONS / INSTRUCTIONS IMPORTAANTES SUR LA SÉCURITÉ
Load Ratings: 2,500 lbs. load rating
Added Weight (Loading): Total added weight should be distributed as follows:
• 1/2 of the total added weight (at a minimum) placed in the bottom third of the enclosure
• 1/4 of the total added weight (at a maximum) palced in the middle third of the enclosure
• 1/4 of the total added weight (at a maximum) placed in the top third of the enclosure
• Enclosure is intended for use in ambient temperatures of 32°F (0°C) to 140°F (60°C).
• Front Door (Optional): Full width door can be hinged on the left or right of the rack frame. Ensure door is bonded to enclosure frame. See Grounding and Bonding on page 6 for details.
• Rear Door: Full width door can be hinged on the left or right of the rack frame. Ensure door is bonded to enclosure frame. See Grounding and Bonding on page 6 for details.
SPECIFICATIONS
GENERAL INFORMATION
Heights: 10 RU to 44 RU (each RU = 1.75”) Widths: 22” Depths: 20”, 25” and 28”
GROUNDING AND BONDING
Protective Earth Terminals (PET) are located on the bottom frame of the enclosure. These terminals are marked with the symbol. Enclosure accessory parts contain or are provided with bonding points for connection to the frame / PET.
Protective earth and bonding connections shall be in accordance with Article 250 of the National Electric Code.
When removing any bonded accessory for servicing the enclosure, make sure to disconnect the bonding terminal from the accessory. NOTE: The bonding terminal MUST be reconnected to the accessory when the part is replaced after servicing.
(1) (1)
OPTIONAL PROTECTIVE EARTH TERMINAL KIT: #PET-K-FD
PARTS LIST
• Door bonding wire [12 Gauge Wire (#10 ring terminal to male disconnect) 6”]
• Door bonding wire [12 Gauge Wire (#10 ring terminal to female disconnect) 4”]
• Thread forming screw M4 x .7
• Locking Nut 10-32
QTY
(1)
(1)
(1)
(1) (1) (1)
PARTS LIST
• Lower door bonding wire [12 Gauge Wire (#10 ring terminal to #10 ring terminal) 14”]
• Lower door bonding wire [12 Gauge Wire (#10 ring terminal to 1/4-20 ring terminal) 14”]
• Flange Nut 10-32
• Flange Nut 1/4-20
• Locking Nut 10-32
QTY
(1)
(1)
(2) (1) (1)
(1)(1)(2)
OPTIONAL PROTECTIVE EARTH TERMINAL KIT: #PET-K-RD
(1)(1)
GROUNDING AND BONDING (Continued)
Door Bonding Points (1 Upper and 1 Lower)
NOTE: The main protective earth conductor needs to be the first terminal placed on the PET and this terminal needs to be secured on its own with a nut.
1) Attach Lower rear door bonding wire from 1/4”-20 protective earth terminal (PET) to door bonding stud (10-32). (FIGURE A)
-OR-
Attach Upper rear door bonding wire from upper bonding stud (10-32) to door bonding stud
(10-32). (FIGURE B)
Door
2) FOR OPTIONAL FRONT DOOR: Attach door bonding wire (with male or female disconnect end) to door bonding point with thread forming screw. (FIGURE C)
3) Attach remaining door bonding wire to nearest bonding stud (10-32). (FIGURE C)
4) Connect male and female ends of door bonding wire set.
Door Bonding Stud (10-32)
Upper Bonding Stud (10-32)
PET Stud (1/4”-20)
Lower Bonding Studs (10-32)
FIGURE A
FIGURE B
FIGURE C
WARRANTY
Middle Atlantic Products (the "Company") warrants the ERK Series Enclosure to be free from defects in material or workmanship under normal use and conditions for the lifetime of the product.
The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of and refund of the price paid for, or (b) repair or replacement at the Company's factory of the products purchased, or any part or parts thereof, which the Company has determined to be defective after inspection thereof at the Company's factory.
This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by parties other than the Company, or any modification or alteration of the products. In addition, this warranty does not cover damage due to improper handling, assembly, installation or maintenance.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF THE PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER PARTY) HEREUNDER, IF ANY, SHALL IN NO
EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS PAID TO THE COMPANY.
Corporate Headquarters Corporate Voice 973-839-1011 - Fax 973-839-1976 / International Voice +1 973-839-8821 - Fax +1 973-839-4982 middleatlantic.com - info@middleatlantic.com
Middle Atlantic Canada Voice 613-836-2501 - Fax 613-836-2690 / middleatlantic.ca - customerservicecanada@middleatlantic.ca
Factory Distribution USA: NJ - CA - IL Canada: ON - BC
At Middle Atlantic Products we are always listening. Your comments are welcome.
Middle Atlantic Products is an ISO 9001 and ISO 14001 Registered Company.
User Manual
Online UPS
UPS-OL1500R | UPS-OL2200R | UPS-OL3000R
THANK YOU
Thank you for purchasing an online UPS product. Please read these instructions thoroughly before installing this product.
PRODUCT FEATURES
Provides double-conversion (zero transfer time) online backup protection.
Expansion battery packs for provisioning additional runtime needs.
Real time reporting and notifications of battery life and when replacement is required.
Removable LCD display and power switch for remote convenience.
I-00778 Rev F
Line
Rectangle
Page ii
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
CONSIGNES DE SÉCURITÉ IMPORTANTES
REGULATORY COMPLIANCE
Federal Communications Commission (FCC) Compliance Statement (Used for 2200 and 3000VA Online UPS
Models)
Industry Canada (IC)
Federal Communications Commission (FCC) Compliance Statement (Used for 1500VA Online UPS Models)
Industry Canada (IC)
UNPACKING
HARDWARE INSTALLATION
Safety Precautions
Précautions de Sécurité
Rackmount Installation
Sliding Out the UPS From the Rackrail
INSTALLING YOUR UPS SYSTEM
System Block Diagram
Hardware Installation Details
BASIC OPERATION
Power Module Front/Rear Panel Descriptions
OPERATION INSTRUCTIONS FOR LCD MODULE
LED Indicators – UPS Status
LCD Screen – UPS Status
Button Operation
LCD SETUP FUNCTIONS
Multi-Function LCD Main Menu
LCD Information Readout
LCD Event Log
LCD Settings Configuration
Silencing Audible Alarms
TABLE OF CONTENTS
Page iii
Manual Battery Test
Graphical Load /Battery Capacity Display
LCD MODULE REMOTE CONTROL and WALL-MOUNTING INSTRUCTIONS
Safety Precautions
Précautions de Sécurité
Remote Control
Wall-Mounting Instructions
MAINTENANCE
Safety Precautions
Précautions de Sécurité
Storage
Replacement Batteries
Battery Disposal
Battery Replacement
UPS MODELS AND CORRESPONDING BATTERY PACKS
TECHNICAL SPECIFICATIONS
TROUBLESHOOTING
WARRANTY
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate the UPS.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an outlet that is not grounded. If you need to power-drain this equipment, turn off and unplug the unit.
CAUTION! The battery can power hazardous components inside the unit, even when the AC input power is disconnected.
CAUTION! The UPS should be placed near the connected equipment and easily accessible.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants. (Please see “Technical Specifications” on page 22 for acceptable temperature and humidity ranges).
CAUTION! (No User Serviceable Parts): Risk of electric shock, do not remove cover. No user serviceable parts inside.
Refer servicing to qualified service personnel.
CAUTION! (Non-Isolated Battery Supply): Risk of electric shock, battery circuit is not isolated from AC power source;
hazardous voltage may exist between battery terminals and ground. Test before touching.
CAUTION! To reduce the risk of fire, connect the UPS to a branch circuit with 15 amperes (UPS-OL1500R) / 20 amperes (UPS-OL2200R) / 30 amperes (UPS-OL3000R) maximum over-current protection in accordance with the National Electric Code, ANSI/NFPA 70.
CAUTION! The AC outlet where the UPS is connected should be close to the unit and easily accessible.
CAUTION! Please use only UL-marked mains cable, (e.g. the mains cable of your equipment), to connect the UPS to the AC outlet.
CAUTION! Please use only UL-marked power cables to connect any equipment to the UPS.
CAUTION! When installing the equipment, ensure that the sum of the leakage current of the UPS and the connected equipment does not exceed 3.5mA.
CAUTION! The UPS-OL1500R / UPS-OL2200R / UPS-OL3000R models may only be installed by qualified maintenance personnel.
CAUTION! Do not unplug the unit from AC Power during operation, as this will invalidate the protective ground insulation.
CAUTION! To avoid electric shock, turn off and unplug the unit before installing the input/output power cord with a ground wire.
Connect the ground wire prior to connecting the line wires!
CAUTION! Do not use an improper size power cord as it may cause damage to your equipment and cause fire hazards.
CAUTION! Wiring must be done by qualified personnel.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT
EQUIPMENT! Under no circumstances this unit should be used for medical applications involving life support equipment and/or patient care.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or near aquariums.
Condensation from the aquarium can come in contact with metal electrical contacts and cause the machine to short out.
CAUTION! Do not dispose of batteries in fire as the battery may explode.
CAUTION! Do not open or mutilate the battery, released electrolyte is harmful to the skin and eyes.
CAUTION! A battery can present a risk of electric shock and high short circuit current. The following precautions should be observed when working on batteries:
1. Remove watches, rings or other metal objects.
2. Use tools with insulated handles.
3. Wear rubber gloves and boots.
4. Do not lay tools or metal parts on top of batteries.
5. Disconnect charging source prior to connecting or disconnecting battery terminals.
6. Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground.
Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.
CAUTION! The unit has a dangerous amount of voltage. When the UPS indicators is on, the units may continue to supply power thus the unit’s outlets may have a dangerous amount of voltage even when it’s not plugged in to the wall outlet.
CAUTION! Make sure everything is turned off and AC power is disconnected completely before conducting any maintenance, battery replacement, repairs or shipment.
CAUTION! Connect the Protection Earth (PE) safety conductor before any other cables are connected.
WARNING! (Fuses): To reduce the risk of fire, replace only with the same type and rating of fuse.
DO NOT INSTALL THE UPS WHERE IT WOULD BE
EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG
HEAT SOURCE!
DO NOT BLOCK OFF VENTILATION OPENINGS AROUND
THE HOUSING!
DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS
HAIR DRYERS TO UPS OUTPUT SOCKETS!
SERVICING OF BATTERIES SHOULD BE PERFORMED OR
SUPERVISED BY PERSONNEL WITH KNOWLEDGE OF
BATTERIES AND THEIR REQUIRED PRECAUTIONS. KEEP
UNAUTHORIZED PERSONNEL AWAY FROM BATTERIES!
THE SOCKET-OUTLET SHALL BE INSTALLED NEAR THE
EQUIPMENT AND SHALL BE EASILY ACCESSIBLE.
CONSIGNES DE SÉCURITÉ IMPORTANTES
Ce manuel contient des instructions importantes. S'il vous plaît lire et suivre attentivement toutes les instructions lors de l'installation et le fonctionnement de l'unité. Lisez attentivement ce manuel avant de déballer, installer ou utiliser l'onduleur.
ATTENTION! L'onduleur doit être connecté à une prise d'alimentation secteur à la terre avec protection fusible ou un disjoncteur. Ne branchez pas le UPS dans une prise qui ne sont pas mis à la terre. Si vous avez besoin de puissance-drain cet équipement, éteignez et débranchez l'appareil.
ATTENTION! La batterie peut alimenter des composants dangereux dans l'appareil, même lorsque la puissance d'entrée CA est débranché.
ATTENTION! L'onduleur doit être placé près de l'équipement connecté et facilement accessible.
ATTENTION! Pour prévenir le risque d'incendie ou de choc électrique, installer dans une température et humidité contrôlées zone couverte, exempt de contaminants conducteurs. (S'il vous plaît voir "Spécifications techniques" à la page 22 pour température et d'humidité acceptables).
ATTENTION! (Aucune pièce réparable): risque de choc électrique, ne pas retirer le couvercle. Aucune pièce réparable par l'utilisateur. Confiez l'entretien à du personnel qualifié.
ATTENTION! (Alimentation Batterie non-isolé): Risque de choc électrique, le circuit de la batterie est pas isolé de la source d'alimentation; tension dangereuse peut exister entre les bornes de la batterie et la terre. Test avant de les toucher.
ATTENTION! Pour réduire le risque d'incendie, de connecter l'onduleur à un circuit de dérivation de 15 ampères (UPS-OL1500R) / 20 ampères (UPS-OL2200R) / 30 ampères (UPS-OL3000R) maximale de protection de surintensité en conformité avec le Code national de l'électricité , ANSI / NFPA 70.
ATTENTION! La prise secteur où l'onduleur est connecté doit être proche de l'appareil et facilement accessible.
ATTENTION! S'il vous plaît utilisez uniquement UL marqué câble d'alimentation, (par exemple le câble d'alimentation de votre équipement), pour connecter l'onduleur à la prise secteur.
ATTENTION! S'il vous plaît utiliser les câbles d'alimentation ne UL-marqués pour connecter un équipement à l'onduleur.
ATTENTION! Lors de l'installation de l'équipement, veiller à ce que la somme du courant de fuite de l'onduleur et l'équipement connecté ne dépasse pas 3,5 mA.
ATTENTION! Les UPS-0LEBPR-1 / UPS-0LEBPR-2 modèles doivent être installés par le personnel de maintenance qualifié.
ATTENTION! Ne pas débrancher l'appareil de l'alimentation secteur pendant l'opération, car cela annulerait l'isolation de la terre de protection.
ATTENTION! Pour éviter un choc électrique, éteignez et débranchez l'appareil avant d'installer le cordon d'alimentation d'entrée / sortie avec un fil de terre. Branchez le fil de terre avant de connecter de la lignes.
ATTENTION! Ne pas utiliser une taille incorrecte cordon car cela peut causer des dommages à votre équipement et causer des risques d'incendie.
ATTENTION! Les travaux de câblage doit être effectué par du personnel qualifié.
ATTENTION! NE PAS UTILISER POUR DES APPAREILS DE
MÉDICAL OU SOUTIEN DE LA VIE! En aucun cas, cet appareil doit être utilisé pour des applications médicales impliquant l'équipement de soutien de vie et / ou les soins aux patients.
ATTENTION! NE PAS UTILISER AVEC OU PROXIMITÉ D'UN
AQUARIUM! Pour réduire le risque d'incendie, ne pas utiliser avec ou près des aquariums. La condensation de l'aquarium peut entrer en contact avec des contacts électriques métalliques et provoquer à court-circuit.
ATTENTION! Ne jetez pas les batteries au feu, car la batterie pourrait exploser.
ATTENTION! Ne pas ouvrir ni mutiler la batterie, l'électrolyte libéré est nocif pour la peau et les yeux.
ATTENTION! Une batterie peut présenter un risque de choc électrique et de courant de court circuit élevé. Les précautions suivantes doivent être observées lors de travaux sur les batteries:
1. Retirez montres, bagues ou autres objets métalliques.
2. Utilisez des outils isolés.
3. Portez des en caoutchouc gants et des bottes.
4. Ne pas poser d'outils ou de pièces métalliques sur les batteries.
5. Débranchez la source avant de connecter ou déconnecter les bornes de recharge des batteries.
6. Déterminer si la batterie est mise à la terre par inadvertance. Si la terre par inadvertance, retirer la source à partir du sol. Le contact avec une partie d'une batterie mise à la terre peut provoquer un choc électrique. La probabilité d'un tel choc peut être réduite si ces motifs sont supprimés lors de l'installation et la maintenance.
ATTENTION! L'unité dispose d'une quantité dangereuse de tension. Lorsque les indicateurs UPS est en marche, les unités peuvent continuer à alimenter ainsi les points de vente de l'unité peut avoir une quantité dangereuse de tension même quand il est pas branché à la prise murale.
ATTENTION! Assurez-vous que tout est éteint et alimentation secteur est débranchée complètement avant de procéder à tout entretien, le remplacement de la batterie, réparations ou l'expédition.
ATTENTION! Raccorder de la terre de protection (PE) conducteur de sécurité avant tous les autres câbles sont connectés.
AVERTISSEMENT! (Fusibles): Pour réduire le risque d'incendie, ne remplacer avec le même type et calibre du fusible.
NE PAS INSTALLER L'ONDULEUR OÙ IL SERAIT EXPOSÉ
DIRECTEMENT AU SOLEIL OU PRÈS D'UNE SOURCE DE
CHALEUR!
NE PAS BLOQUER OUVERTURES DE VENTILATION
AUTOUR DU BOÎTIER!
NE PAS CONNECTER APPAREILS DOMESTIQUES, POUR
LES SÉCHOIRS EXEMPLE CHEVEUX, DANS LES PRISES
DE SORTIE DE L'UPS!
ENTRETIEN DES BATTERIES DOIT ÊTRE EFFECTUÉ OU
SUPERVISÉ PAR UN PERSONNEL QUI A CONNAISSANCE
DE BATTERIES ET LEURS PRÉCAUTIONS REQUISES.
GARDER LE PERSONNEL NON AUTORISÉ LOIN DES
BATTERIES!
LA PRISE DE COURANT DOIT ÊTRE INSTALLÉE PRÈS DE
L'ÉQUIPEMENT ET DOIT ÊTRE FACILEMENT
ACCESSIBLE.
REGULATORY COMPLIANCE
Federal Communications Commission (FCC) Compliance Statement
(Used for 2200 and 3000VA Online UPS Models) NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
REMARQUE: Cet équipement a été testé et jugé conforme aux limites de la classe A des appareils numériques, conformément à la section 15 de la réglementation de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles lorsque l'équipement est utilisé dans un environnement commercial. Cet équipement génère, utilise et peut émettre de l'énergie radiofréquence et, si non installé et utilisé conformément au manuel d'instruction, peut provoquer des interférences dans les communications radio. Le fonctionnement de cet équipement dans une zone résidentielle est susceptible de provoquer des interférences nuisibles, auquel cas l'utilisateur sera tenu de corriger les interférences à ses propres frais.
CAUTION! Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
ATTENTION! Les changements ou modifications non expressément approuvés par le fabricant peuvent annuler le droit de l'utilisateur à utiliser l'équipement.
Industry Canada (IC) ICES-003 Class A Notice - Avis NMB-003, Classe A This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Federal Communications Commission (FCC) Compliance Statement
(Used for 1500VA Online UPS Models) CAUTION! Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
ATTENTION: Les changements ou modifications non expressément approuvés par la partie responsable de la conformité pourraient annuler l'autorité de l'utilisateur à utiliser l'équipement.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
REMARQUE: Cet équipement a été testé et jugé conforme aux limites d' un dispositif numérique de classe B, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle . Cet équipement génère , utilise et peut émettre de l'énergie radiofréquence et, si non installé et utilisé conformément aux instructions, peut provoquer des interferences dans les communications radio. Cependant, il n'y a aucune garantie que des interférences ne se produiront pas dans une installation particulière. Si cet équipement provoque des interférences nuisibles à la réception radio ou de télévision, ce qui peut être déterminé en allumant et éteignant l'équipement, l'utilisateur est encouragé à essayer de corriger l'interférence par une ou plusieurs des mesures suivantes:
Réorienter ou déplacer l' antenne de réception.
Augmenter La distance entre l'équipement et le récepteur.
Brancher l'équipement dans une prise sur un circuit différent de celui sur lequel est branché le récepteur.
Consulter le revendeur ou un technicien radio / TV expérimenté.
Industry Canada (IC) ICES-003 Class B Notice - Avis NMB-003, Classe B This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
UNPACKING
1.5KVA or 2.2K/3KVA UPS
Quick Start Guide
Rackmount Left Rail Rackmount Right Rail
Left Hanging Bracket Right Hanging Bracket
Rackmount Ears (2)
Phone Line
USB Communication Cable
Serial Interface Cable (RS-232)
Pan Head Screws: M5x12L (4)
Flat Head Screws: M5x7L (8)
Pan Head Screws: M5x6L (6)
Pan Head Screws: 10-32x1/2L (12)
Screw Hole Dust Covers (12)
HARDWARE INSTALLATION
Safety Precautions CAUTION! This unit is heavy; lift carefully. A two person lift is recommended.
CAUTION! Lift the battery pack out of the shipping box by firmly holding both sides of the unit. Do not lift the battery pack out of the shipping box while holding the front face of the unit, as this may cause damage.
CAUTION! Installation environment should be in a temperature and humidity controlled, indoor area free of conductive contaminants.
Do not install this UPS where excessive moisture or heat is present (Please see “Technical Specifications” on page 22 for acceptable temperature and humidity ranges).
CAUTION! Never install a UPS, or associated wiring or equipment, during a lightning storm.
CAUTION! Do not work alone under hazardous conditions.
CAUTION! In case of the risk of electric shock, do not remove the top cover.
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is disconnected.
CAUTION! To prevent the risk of fire or electric shock, only use the supplied hardware to attach the mounting brackets.
Précautions de Sécurité ATTENTION! Cet appareil est lourd; soulevez avec attention. A deux personnes ascenseur est recommandé.
ATTENTION! Soulevez la batterie hors de la boîte de transport en tenant fermement les deux côtés de l'unité. Ne pas soulever la batterie hors de la boîte de transport tout en maintenant la face avant de l'appareil, car cela pourrait causer des dommages.
ATTENTION! Environnement d'installation devrait être en température et humidité contrôlées espace intérieur exempt de contaminants conducteurs. Ne pas installer cet onduleur où l'humidité excessive ou à la chaleur est présente (S'il vous plaît voir "Spécifications techniques" à la page 22 pour température et d'humidité acceptables).
ATTENTION! Ne pas travailler seul dans des conditions dangereuses.
ATTENTION! Ne jamais installer cet onduleur, batterie, ou le câblage ou équipement correspondant, au cours d'un orage avec foudre.
ATTENTION! Ne pas retirer le couvercle supérieur. Retrait du capot peut risquer un choc électrique.
ATTENTION! La batterie peut dynamiser les parties actives dangereuses à l'intérieur même lorsque la puissance d'entrée CA est débranché.
ATTENTION! Pour éviter le risque d'incendie ou de choc électrique, utilisez uniquement le matériel fourni pour fixer les supports de montage.
Rackmount Installation
NOTE: Some rackmount steps are pictured with the Online Expansion Battery. The rackmount mounting procedure is the same for both products.
1. Turn off and unplug the unit.
2. Remove the (7) dust covers by prying them from the screw holes.
3. Install (2) rackmount ears using (8) M5x7L flat head screws. Also, install (2) hanging brackets using (6) M5x6L pan head screws.
4. Install your rackmount rails. The rails adjust to mount in 48cm (19”) panel racks from 52 to 91.5cm (20.5 to 36”) deep. Select the proper holes in the rack for positioning the UPS in the rack. The UPS takes up positions 1 through 6.
5. Adjust the rackrail depth within specified mounting ranges from step 4. Attach the rackmount rail to your rack with (8) 10-32x1/2L screws and (2 screws for both front and back and for each rail). Tighten all screws.
6. Slide hanging brackets on the UPS into the rails mounted in the rack with the front of the unit facing you. Secure the UPS to your rack with (4) 10-32x1/2L screws on the front of the rack (located in positions 2 and 5).
Position 6
Position 5
Position 2
2U Front Installation
Position 6 Position 5 Position 4 Position 3 Position 2 Position 1
For Rackmount Ears
For Rails
2U Rear Installation
Position 6 Position 5 Position 4 Position 3 Position 2 Position 1
For Rails
Position 1
Position 5
Position 2
Sliding Out the UPS From the Rackrail
1. Turn off and unplug the unit.
2. The UPS is secured from being pulled out of the rack any further than its mid-length by a safety lock mechanism. Use both hands to hold the UPS and press the safety locking tabs to pull the UPS out of the rack.
INSTALLING YOUR UPS SYSTEM
NOTE: The steps in this section should only be performed after completing the hardware installation procedures. For more information, see “Hardware Installation” on page 8.
System Block Diagram
Hardware Installation Details
1. Battery charge loss may occur during shipping and storage. Before using the UPS, it’s strongly recommended to charge the batteries for four hours to ensure their maximum charge capacity. To recharge the batteries, plug the UPS into an AC outlet.
2. When using the software, connect either the serial or the USB cable between the computer and the corresponding port on the UPS.
NOTE: If the USB port is used, the serial port will be disabled. They cannot be used simultaneously.
After connecting to either the USB port or the Serial port on the UPS, a computer with the Middle Atlantic Power Manager Software installed can control the operating schedule, battery test, outlets, as well as obtain UPS status information. However, other computers with Middle Atlantic Power Manager Software can only obtain UPS status information via LAN connection.
3. Connect your computer, monitor, and any externally powered data storage device (hard drive, tape drive, etc.)
into the outlets only when the UPS is off and unplugged.
DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the UPS. The power demands of these devices will overload and possibly damage the unit.
4. To protect a fax machine, telephone, modem line or network cable, connect the telephone or network cable from the wall jack outlet to the jack marked “IN” on the UPS and connect a telephone cable or network cable from the jack marked “OUT” on the UPS to the modem, computer, telephone, fax machine, or network device.
5. Press the ON/OFF switch to power on the UPS. The Power-On indicator light will display when activated. If an overload is detected, an audible alarm will sound and the UPS will continuously emit two beeps per second. Before resetting the unit, unplug some equipment from the outlets first. Make sure your equipment carries a load current within the unit’s safe range. See “Technical Specifications” on page 22 for more information.
6. This UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge, even when the unit is switched off.
7. To maintain an optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. Before storing the UPS for an extended period of time, turn the unit OFF. Then cover it and store it with the batteries fully charged. Recharge the batteries every three months to ensure their full capacity and maintain the longest possible battery life. Maintaining a good battery charge will help prevent possible damage to the unit from battery leakage.
9. The UPS has one USB port (default) and one Serial port that allow connection and communication between the UPS and any attached computer running the Middle Atlantic Power Manager Software. The UPS can control the computer’s shutdown during a power outage through the connection while the computer can monitor the UPS and alter various programmable parameters.
NOTE: Only one communication port can be used at a time. The port not in use will automatically become disabled or the serial port will be disabled if both ports are attached.
10. EPO (Emergency Power Off) Port: EPO ports allow administrators the capability to connect the UPS unit to customer-supplied EPO switches. These installations give operators a single access point to immediately power-off all equipment connected to the UPS during an emergency.
11. To avoid electric shock, turn the unit OFF and disconnect the unit from utility power before plugging in the power cord. The power cord must be connected to a properly wired and grounded outlet.
12. The internal UPS temperature increases when fans are not in operation or ventilation is obstructed. When the high temperature sensor activates protection, the UPS generates an alarm and shuts down to avoid unexpected equipment damage. If overtemperature occurs, see “Troubleshooting” on page 23. If the condition persists, contact Middle Atlantic Product’s technical support at 1-800-266-7225.
BASIC OPERATION
Power Module Front/Rear Panel Descriptions
1. Power Button / Power on Indicator:
Master ON/OFF for the UPS. Indicates that the UPS is on and supplying power.
2. UPS Status / Fault / Replace Battery LED Indicator:
Indicates the status of the UPS, displaying whether it is operating in Line, Battery or Bypass Mode, if it has an internal fault or if the battery needs to be replaced.
3. Multifunction LCD Readout:
Shows UPS status, information, settings and events.
4. Function Buttons:
Scroll up, scroll down, select and cancel LCD menu.
5. Input Circuit Breaker:
Provides input overload and fault protection.
6. Battery Backup and Surge Protected Outlets:
Provides battery backup and surge protection. They ensure power is provided to connected equipment over a period of time during a power failure.
Critical / Noncritical Load:
Allows the creation of load priorities to ensure that battery power reserves are transferred to specified outlets during a power outage. The unit can be programmed to provide additional runtime for equipment connected to the “CRITICAL” outlets, while stopping the power supply to equipment connected to “NONCRITICAL” outlets after a designated period of time.
7. Serial Port:
The serial port provides communication between the UPS and the computer. The UPS can control the computer’s shutdown during a power outage through this connection while the computer can monitor the UPS and alter its various programmable parameters.
8. USB Port:
This is a connectivity port which allows communication and control between the UPS and the connected computer. It is recommended to install the Middle Atlantic Power Manager Software on the PC or Server connected using the USB cord provided.
9. Surge Protected Communication Ports
RJ-45:
These ports are used to protect standard RJ-45-based products (LAN lines) and cabling systems from surges.
10. Relay Output Connector:
Converts UPS signals into a single dry-contact output for industrial control.
11. SNMP/HTTP Network Slot:
Slot to install the optional UPS-OLIPCARD for remote network control and monitoring.
UPS-OL1500R
UPS-OL2200R
UPS-OL3000R
12. Extended Runtime Battery Module Connector:
Connection for additional Middle Atlantic External Battery modules.
13. EPO (Emergency Power Off) Connector:
Enables an emergency UPS Power Off from a remote location.
14. AC Input Inlet:
Connect the AC Power cord to a properly wired and grounded outlet.
15. Output Shutoff Switch:
Pressing this button causes the UPS output to turn off. To re-activate the outputs, press and hold the power button for a few seconds until the front panel display reads READY ON.
4 1
OPERATION INSTRUCTIONS FOR LCD MODULE
LED Indicators – UPS Status
LED Indicators Color UPS Status Description
ON/OFF White UPS power is on.
Green UPS is operating in Line Mode.
Yellow UPS is operating in Battery Mode.
Yellow UPS is operating in Bypass Mode, Manual Bypass or ECO (Economy) Mode.
Red UPS has an internal fault. See “Troubleshooting” on page 23 for more information.
Red Battery will soon need to be replaced due to insufficient runtime.
LCD Screen – UPS Status
LCD Screen UPS Status Description
Line Mode UPS is operating in Line Mode.
This state provides constant sinewave output regardless of the input voltage state.
Battery Mode UPS is operating in Battery Mode.
This state is enabled whenever utility power is disengaged.
Bypass Mode UPS is operating in Bypass Mode.
This state is enabled when the UPS detects an overload, DC bus (Bus Fault), inverter (High O/P V or Low O/P V), or over temperature (Over Temp) fault.
Manual Bypass UPS is operating in Manual Bypass.
This state allows you to force a change of output (to bypass).
ECO Mode UPS is operating in ECO (Economy) Mode.
An operating state that reduces wasted energy by bypassing the rectifier and inverter when AC power input is detected to be within a pure sine wave standard.
Button Operation
Button Operation Description
ON/OFF Press this button to turn the UPS on or off.
▲ Press this button to scroll up in the LCD menu.
▼ Press this button to scroll down in the LCD menu.
ENTER Press this button to select an option.
ESC Press this button to cancel or return to previous LCD menu.
LCD SETUP FUNCTIONS
Multi-Function LCD Main Menu
Press “Enter” button to activate “MAIN MENU”.
MAIN MENU submenu Function Description
Information Displays the UPS information.
Configure Displays the UPS settings that can be configured by the user.
Event Log Displays the five most recent events by event count, time (day/hour/minute), and event description.
LCD Information Readout
There are 19 types of UPS information available for display.
1. Press the “ENTER” button to activate the “MAIN MENU”.
2. Press the “▲” and “▼” buttons to scroll to the “Information” option.
3. Press the “ENTER” button to select the “Information” submenu.
4. Press the “▲” and “▼” buttons to scroll through the “Information” submenu in the following table.
5. Press the “ESC” button to return to UPS Status.
Information Submenu Description
O/P Volt = XXX.XV Displays the Output Voltage
O/P Freq = XX.XHz Displays the Output Frequency
I/P Volt = XXX.XV Displays the Input Voltage
I/P Freq = XX.XHz Displays the Input Frequency
O/P Load = XXX% Displays the Output Load as a Percentage of Maximum load
O/P Amp = X.XA Displays the Output Current
O/P Watt =XXXXXW Displays the Output Wattage
O/P VA =XXXXXVA Displays the Output VA
BAT Volt = XXX.XV Displays the Battery Voltage
BAT Cap = XXX% Displays the Estimated Percentage of Battery Capacity
BAT Runtime =XXXM Displays the Estimated Battery Runtime in Minutes
EBM Number = X Displays the External Battery Module Number
TEMP =XX°C /
XXX°F
Displays the Approximate inside Temperature in both ℃(Celsius) and ℉(Fahrenheit) for the UPS
SBM = XXXXX XH(M) Displays the stage of Smart Battery Management with Operation Time
Rating = XXK VA Displays the UPS Rating
MCU Ver = XXXX Displays the MCU Firmware Version
Model Name Displays the UPS Model Name
Date & Time
Displays the present Date and Time
Next BAT Change
XXX / XXXX
Displays the next Battery Change Date and Time
LCD Event Log
Five UPS Event Logs can be recorded.
1. Press the “ENTER” button to activate the “MAIN MENU”.
2. Press the “▲” and “▼” buttons to scroll to the “Event Log” option.
3. Press the “ENTER” button to select the “Event Log” submenu.
4. Press the “▲” and “▼” buttons to scroll through the “Event Log” submenu in the following table.
5. Press the “ESC” button to return to UPS Status.
Event Log Submenu Description
(X)
XXDXXHXXM (without Middle Atlantic Power Manager Software or
UPS-OLIPCARD)
- - / - - - -:- - (with Middle Atlantic Power Manager Software or UPS-OLIPCARD)
Event Content
LCD Settings Configuration
There are 22 UPS settings that can be configured by the user.
1. Press the “ENTER” button to activate the “MAIN MENU”.
2. Press the “▲” and “▼” buttons to scroll to the “Configure” option.
3. Press the “ENTER” button to select the “Configure” submenu.
4. Press the “▲” and “▼” buttons to scroll to the “Configure” submenu in the following table.
5. Press the “ENTER” button to select the setting you want to configure.
The first configuration parameter will be displayed on the second column of LCD screen.
6. Press the “▲” and “▼” buttons to scroll through the different parameters.
7. Press the “ENTER” button to select the parameter you want to change.
You may be prompted to save the selection, if so press the “ENTER” button to save the setting. Some options are saved and started automatically. (See the following table for more information.)
8. Press the “ESC” button to cancel or return to the previous LCD menu.
Configuration Submenu
Available Settings Default Setting
Description
Output Voltage1 = [100V] [110V] [115V] [120V] [125V] 120V Configures the output voltage.
Sync Freq Window Range= [+/- 1%] [+/- 2%] [+/- 3%] [+/- 4%] [+/- 5%]
[+/- 6%] [+/- 7%] [+/- 8%] [+/- 9%] [+/-10%] +/- 5%
Allows you to specify a permitted output frequency range.
Bypass V Window Range= [+10%/-10%] [+10%/-15%] [+10%/-20%]
[+15%/-10%] [+15%/-15%] [+15%/-20%]
+10%/-15
Allows you to specify a permitted bypass output voltage range.
Bypass Condition [Check Freq/Volt] [Check Volt Only] [No Bypass] Check
Freq/Volt
Transfers UPS to Bypass mode when the specified condition is met.
ECO Mode2
[Disable] [Enable] Disable When enabled, the UPS operates in Bypass mode for higher efficiency. In the event of a power failure, the UPS transfers to the inverter in less than 10 ms.
[V Range= +/-15%] [V Range= +/-10%] (for [Enable]) V Range=
+/-10%
Manual Bypass [Disable] [Enable] Disable Enables or disables bypass mode manually.
Configuration Submenu
Available Settings Default Setting
Description
UPS Diagnostic [Battery Test] [Alarm Test] [Indicator Test] [Fan Test]
Battery
Test
Initiates a self-test for the battery/alarm/indicator/fan.
[Activate?] None
Audible Alarms [Disable] [Enable] Enable Enables or disables audible alarms.
EBM Number = [0] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] 0
Used for setting the number of extended battery modules in order to calculate the correct estimated runtime value.
Wiring Fault [Disable] [Enable] Disable Enables or disables a check for the input plug connection.
NCL Control [Outlet On] [Outlet Off] Outlet On Controls the non-critical load output via corresponding outlets.
Generator Mode3 [Disable] [Enable] Disable
Provides stable sine wave output that is free of harmonics and distortion without switching to battery mode when running on generator input power.
Communication [Disable] [Enable] Enable Enables or disables all communication.
Dry Relay Set [I/P Power Fail] [Battery Low] [Summary Alarm]
[UPS On Bypass] [UPS Fail]
I/P Power
Fail
The dry relay may be set to close when assigned to one of the five available conditions.
Converter Mode4 [Converter Off] [O/P Freq = 50Hz] [O/P Freq = 60Hz] Converter
OFF
Sets the UPS converter to OFF, 50Hz, or 60Hz.
Screen Saver [Disable] [1 Minutes] [5 Minutes] 5 minutes When enabled, sets the LCD screen saver to initiate after either 1 or 5 minutes of inactivity.
Clear Event Log [Activate?] None Clears all LCD event log information from the UPS.
Button OFF LOCK [Disable] [Enable] Disable When enabled, disables ON/OFF button functionality.
Charger Function [SBM] [Constant] SBM
When charging batteries, this sets the charger function to either SBM (smart battery management) or constant voltage.
Signal Inputs [Disable] [EPO] [ROO] Disable
When enabled, sets the signal inputs as either EPO (emergency power off) or ROO (remote on or off) to remote control the UPS. An open circuit activates the EPO. In ROO mode, an open circuit turns the UPS off.
Charger Check [Disable] [Enable] Disable When enabled, checks the electric circuit of the charger.
Reset ReplaceBAT [Activate?] None When the replace battery LED is flashing, replace the battery and reset the battery timer.
UPS-OL1500R/UPS-OL2200R/UPS-OL3000R, 100V is derated by 20%, 110V/115V is derated by 10%
Output voltage default setting varies by country.
2 This function can’t be set when Manual Bypass, Generator Mode or Converter Mode is enabled.
3 UPS has no bypass when Generator Mode is enabled.
UPS has no bypass when Converter Mode is enabled. This function can only be set before the UPS is on.
Silencing Audible Alarms
1. Press any of the four function buttons on the LCD module.
NOTE: the alarm cannot be turned off for a “Battery Low” condition. This condition will still result in an audible alarm.
2. Change the 'Audible Alarms' option to 'Disable' in the LCD screen and it will no longer sound an alarm when malfunctions occur.
Manual Battery Test
Select 'Active' in the 'Battery Test' portion of the LCD screen and the unit will perform a manual battery test.
Graphical Load /Battery Capacity Display
1. Press the “ESC” button to return to UPS Status.
2. Press the “▲” and “▼” buttons to scroll to the “LOAD“ and “BAT“ Capacity.
3. Press the “▲” and “▼” buttons to scroll to the “Charging” or “Discharging” Capacity.
LOAD and BAT Capacity
The LCD screen displays the Load and Battery capacity with a graphical icon.
Charging Capacity
The LCD screen displays the battery capacity during charging with a graphical icon while on Line Mode.
Discharging Capacity
The LCD screen displays the remaining battery capacity with a graphical icon while on Battery Mode.
LCD MODULE REMOTE CONTROL and WALL-MOUNTING INSTRUCTIONS Safety Precautions
CAUTION! These steps must only be performed by qualified personnel.
CAUTION! To avoid electric shock, turn off and unplug the unit before performing “Remote Control” or “Wall-Mounting Instructions”.
Précautions de Sécurité
ATTENTION! Ces étapes doivent être réalisées uniquement par du personnel qualifié.
ATTENTION! Pour éviter un choc électrique, éteignez et débranchez l'appareil avant d'effectuer "Remote Control" ou "Instructions
Mur-Montage".
Remote Control
1. Turn off and unplug the unit.
2. Remove the multifunction LCD module by unscrewing the right panel, separating it from the UPS, and gently lifting the LCD module out. Reinstall the right panel.
3.…