A-311 WALL SECTIONS.pdf

PDF 396 KB Posted

Attached to
Renovation of 3rd floor building 13A
Solicitation number
FA282325R0008
Issued by

About this file

The document is a detailed architectural drawing (A-311) for a security wall section and wall type details for the DTRA Renovation project at the 3rd Floor of Building 13A at Eglin Air Force Base in Florida. The drawing provides technical specifications for constructing RF-shielded security walls, including:

Key construction details include 3 5/8" 16Ga galvanized metal studs at 16" on center, two layers of 5/8" gypsum wall board (first layer taped and mudded, second layer taped, mudded, and finished), continuous acoustical sealant, SAFB insulation, and specific requirements for window infill using 4 x 8 x 16 nominal masonry CMU. The wall is designed to meet Sound Transmission Class (STC) 50 minimum and incorporates RF shielding, with specific attention to sealing and attachment methods at various structural interfaces. The drawing is part of a renovation project estimated between $5-10 million, focusing on modifying approximately 6,800 square feet of interior space.

View the file

Other files

File Type Posted
04 20 00.pdf PDF
08 71 00.pdf PDF
06 41 16.00 10.pdf PDF
AD-101 DEMOLITION PLAN.pdf PDF
A-110 NEW WORK REFLECTED CEILING PLAN.pdf PDF
DTRA 13A 3rd Floor RFIs_all_Contracting_FINAL.docx DOCX document
EGLIN EMCS AND-OR DDC SYSTEM REQUIREMENTS.pdf PDF
A-312 WALL SECTIONS.pdf PDF
22 00 00.pdf PDF
A-310 WALL SECTION.pdf PDF
Addendum 1 _DTRA Renovation 3rd Floor Bldg 13a.docx DOCX document
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

KEYNOTES:

RUBBER WALL BASE, SEE FINISH SCHEDULE SHEET I-601.

2' X 2' X 3/4" THICK LAY-IN ACOUSTICAL CEILING TILE AND GRID SYSTEM, TYPICAL.

SEE FINISH SCHEDULE SHEET I-601.

ACOUSTICAL SEALANT, CONTINUOUS EACH SIDE, TOP AND BOTTOM OF WALL

EXISTING CONCRETE STRUCTURE

EXISTING FLOOR SLAB

(2) LAYERS 5/8" GYPSUM WALL BOARD, EXTEND TO EXISTING CONCRETE

STRUCTURE ABOVE WITH ACOUSTICAL SEALANT AT FLOOR AND CONCRETE DECK

ABOVE. FIRST LAYER SHALL BE TAPED AND MUDDED BUT NOT FINISHED. SECOND

LAYER SHALL BE TAPED AND MUDDED AND FINISHED CONTINUOUS TO UNDERSIDE

OF EXISTING CONCRETE STRUCTURE ABOVE AND SEAL. ALL JOINTS SHALL BE

STAGGERED ON BOTH LAYERS.

3 1/2" SAFB INSULATION WHERE INDICATED

3 5/8" 16Ga GALVANIZED METAL STUDS @ 16" O.C. HELD 1/2" OFF FACE OF

EXISTING CONSTRUCTION. TRACK SET IN 2 BEADS ACOUSTICAL SEALANT.

EXISTING EXTERIOR CONSTRUCTION

STEEL J TRACK

rFOIL SHIELDING (PERFORATED), WRAP AT FLOOR AND SECURE GYPSUM BOARD

CEILING ABOVE. LAP 8" MIN. PROVIDE CONT. RF SHIELDING OVER EXISTING

CONCRETE DECK INSIDE SECURE BOUNDARY.

3 5/8" 16Ga GALVANIZED METAL STUDS @ 16" O.C.

3 5/8" 16Ga GALVANIZED METAL STUDS @ 16" O.C.

INFILL EXISTING WINDOW OPENING W/ 4 X 8 X 16 NOMINAL MASONRY CMU.14

15 GALVANIZED UNISTRUT SYSTEM (1 5/8" X 1 5/8" 12 GA. P1000) AT 24"

ATTACHED TO GYPSUM BOARD CEILING STUD JOISTS. SECURE W/ 1/4"

HEX WASHER HEAD SCREWS AT EACH JOIST

16 MITEK RT/S7A S/2.5 W/ (2) 3/16" x1" EMBEDMENT TAPCON ANCHOR TO CONCRETE

JOIST & #10 SCREWS TO LTGA JOIST, @EA. INTERSECTION

17 (2) LAYERS 5/8" GYPSUM WALL BOARD, SECURE TO UNDERSIDE OF CEILING JOIST

FRAMING. FIRST LAYER SHALL BE TAPED AND MUDDED BUT NOT FINISHED.

SECOND LAYER SHALL BE TAPED AND MUDDED AND FINISHED CONTINUOUS,

SEAL. ALL JOINTS SHALL BE STAGGERED ON BOTH LAYERS.

18 3 5/8" 18Ga GALVANIZED METAL STUDS @ 16" O.C.

THIRD

FLOOR

A-311

3"=1'-0"

EXTERIOR

WALL TYPE (RF SHIELDED) - W5

INTERIOR

SECURITY WALL SECTION @ EXTERIOR WINDOW

A-311

W5

SECURITY EXTERIOR

WALL @ WINDOW

3"=1'-0"

4 12

WALL TYPE (RF SHIELDED) -

A-311

3"=1'-0"

SECURITY WALL SECTION

PER ICS 705 WALL TYPE "A" -SOUND GROUP 4

STC 50 (MIN)

WALL TYPE (RF SHIELDED) - W4

THIRD FLOOR

18 12 17

LARGE

CONF. ROOM

VESTIBULE

393 EXIST.

CORRIDOR

15 17

'-0

'-0

A-311

WALL SECTIONS AND PLAN DETAILS

BWA

SCALE: 3" = 1'-0"

2" 4"0 8"

96 CEG, OFFICE FORM 002, FY2013

AS-BUILT

PDM

REVISION DATE DESCRIPTION BY APPR'D

23AJ FTFA23-VH79 23AJ

23 OCT. 2024

AS SHOWN

DTRA RENOVATION

3RD FLOOR BLDG 13A

BASE CIVIL ENGINEER EGLIN

AIR FORCE BASE, FLORIDA

BWA

1 05/22/25 RFI ADJUSTMENTS KRW PDM

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SIGNATURE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

CENM

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

PROJ. ENGR.

AutoCAD SHX Text

CONTENTS

AutoCAD SHX Text

TITLE

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

INDEX NO.

AutoCAD SHX Text

PROJ. NO.

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

96 CEG/CEN

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

BASE CIVIL ENGINEER

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

FILE NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

SHEET OF

Sheets and Views
A-311

File details come from the government source that posted it. Updated .