This document is a Door Hardware specification (Section 08 71 00) for the DTRA Renovation of the 3rd Floor Building 13A at Eglin Air Force Base in Florida. The specification provides comprehensive details for door hardware installation, including requirements for hinges, locks, closers, kick plates, door stops, thresholds, and access control components. The hardware specifications are divided into nine distinct hardware sets covering various door types such as man traps, conference rooms, mechanical rooms, storage areas, and entry points, with each set specifying unique hardware configurations.

The specification emphasizes security and functionality, requiring specific hardware finishes (primarily satin stainless steel), complex keying systems compatible with the base's existing standards, and integration with electronic access control systems. Each hardware set includes multiple components like cam lift hinges, electric power transfers, fail-secure or exit locks, surface closers, kick plates, door stops, and STC (sound transmission class) gasketing. Notable security features include credential-based entry, relay-controlled door locking/unlocking sequences, position switches, card readers, and power supplies, with specific notes about maintaining security protocols and allowing key override access.

View the file

Other files

File Type Posted
04 20 00.pdf PDF
06 41 16.00 10.pdf PDF
AD-101 DEMOLITION PLAN.pdf PDF
A-110 NEW WORK REFLECTED CEILING PLAN.pdf PDF
DTRA 13A 3rd Floor RFIs_all_Contracting_FINAL.docx DOCX document
A-311 WALL SECTIONS.pdf PDF
EGLIN EMCS AND-OR DDC SYSTEM REQUIREMENTS.pdf PDF
A-312 WALL SECTIONS.pdf PDF
22 00 00.pdf PDF
A-310 WALL SECTION.pdf PDF
Addendum 1 _DTRA Renovation 3rd Floor Bldg 13a.docx DOCX document
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DTRA Renovation 3rd Floor Bldg 13A FTFA 23VH79

EGLIN AFB, FL DRAWING/SPEC NO. 23AJ

SECTION 08 71 00

DOOR HARDWARE

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.1 (2013) Butts and Hinges

ANSI/BHMA A156.13 (2012) Mortise Locks & Latches Series 1000

ANSI/BHMA A156.16 (2013) Auxiliary Hardware

ANSI/BHMA A156.18 (2012) Materials and Finishes

ANSI/BHMA A156.21 (2009) Thresholds

ANSI/BHMA A156.4 (2013) Door Controls - Closers

ANSI/BHMA A156.6 (2010) Architectural Door Trim

ANSI/BHMA A156.7 (2003; R 2009) Template Hinge Dimensions

BHMA A156.22 (2012) Door Gasketing and Edge Seal Systems

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 101 (2012; Amendment 1 2012) Life Safety Code

NFPA 80 (2013) Standard for Fire Doors and Other Opening Protectives

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames

UNDERWRITERS LABORATORIES (UL)

UL Bld Mat Dir (2012) Building Materials Directory

1.2 SUBMITTALS

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES.

Provide certification letter that all applicable hardware meets the requirements of Federal Specification FF-L-2890B, with Amendment 2 (Feb 25, 2016).

SECTION 08 71 00 Page 1

See Memorandum For Record - Security Door Hardware, from the Eglin Base Locksmith, attached as an Appendix.

Note that the door hardware professional supplying the door hardware will meet with the security officer and the Eglin Base locksmith to review the hardware submittal prior to install.

SD-02 Shop Drawings

Hardware schedule; G

Keying system

SD-03 Product Data

Hardware items; G

SD-08 Manufacturer's Instructions

Installation

SD-10 Operation and Maintenance Data

Hardware Schedule items, Data Package 1; G

Submit data package in accordance with Section 01 78 23 OPERATION

AND MAINTENANCE DATA.

SD-11 Closeout Submittals

Key Bitting

1.3 HARDWARE SCHEDULE

Prepare and submit hardware schedule in the following form:

Hardware Item

Quantity Size Reference Publi-cation Type No.

Finish Mfr Name and Catalog No.

Key Control Symbols

UL

Mark (If fire rated and listed)

BHMA

Finish Desig-nation

1.4 KEY BITTING CHART REQUIREMENTS

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (AA1, AA2, etc.).

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

c. Tabulation showing which key fits which door.

d. Copy of floor plan showing doors and door numbers.

SECTION 08 71 00 Page 2

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.5 QUALITY ASSURANCE

1.5.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

1.5.2 Key Shop Drawings Coordination Meeting

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware subcontractor, using Activity and Base Locksmith shall meet to discuss key requirements for the facility.

1.6 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown in hardware schedule.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Provide hardware to be applied to metal or to prefinished doors manufactured to template. Promptly furnish template information or templates to door and frame manufacturers. Conform to ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 80 for fire doors and NFPA 101 for exit doors, as well as to other requirements indicated, even if such hardware is not specifically mentioned under paragraph entitled "Hardware Schedule." Provide the label of Underwriters Laboratories, Inc. for such hardware listed in UL Bld Mat Dir or labeled and listed by another testing laboratory acceptable to the Contracting Officer.

2.3 HARDWARE ITEMS

Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark will be visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover.

2.3.1 Hinges

ANSI/BHMA A156.1 , 4-1/2 by 4-1/2 inch unless otherwise indicated.

Construct loose pin hinges for exterior doors and reverse-bevel interior doors so that pins will be nonremovable when door is closed. Other antifriction bearing hinges may be provided in lieu of ball-bearing hinges.

SECTION 08 71 00 Page 3

2.3.2 Locks and Latches

2.3.2.1 Mortise Locks and Latches

ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2.

Provide mortise locks with escutcheons not less than 7 by 2-1/4 inch with a bushing at least 1/4 inch long. Cut escutcheons to suit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges. Install knobs and roses of mortise locks with screwless shanks and no exposed screws.

2.3.3 Cylinders and Cores

Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Provide cylinders and cores with seven pin tumblers. Provide cylinders from products of one manufacturer, and provide cores from the products of one manufacturer, compatible with "best" locking system in use at Eglin AFB. Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.

2.3.4 Keying System

Provide a master key system for the facility compatible with the Eglin AFB Base keying system. Provide construction interchangeable cores when subcontractors require keys during construction. The Contractor shall coordinate a keying system meeting. The Contractor's Project Manager, Superintendent, Hardware Subcontractor, Contracting Officer, Base Hardware Specialist, Electrical Subcontractor, and the Using Activity shall attend this meeting to establish the keying system for the project. This meeting is intended to verify base limitations, the necessary security, and access control within the facility. The meeting shall produce a marked up copy of the floor plan together, and any master keying or grand master keying.

2.3.5 Lock Trim

Cast, forged, or heavy wrought construction and commercial plain design.

2.3.5.1 Lever Handles

Provide lever handles in lieu of knobs where indicated in paragraph entitled "Hardware Schedule". Conform to the minimum requirements of ANSI/BHMA A156.13 for mortise locks of lever handles for exit devices.

Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.6 Keys

Furnish one file key, one duplicate key, and three working keys for each key change and for each master and grand master keying system.

2.3.7 Closers

ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at

SECTION 08 71 00 Page 4 storefront mounting, cement cases, and other features necessary for the particular application. Size closers in accordance with manufacturer's recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.

2.3.7.1 Identification Marking

Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation located to be visible after installation.

2.3.8 Door Protection Plates

ANSI/BHMA A156.6 .

2.3.8.1 Sizes of Armor Mop and Kick Plates

2 inch less than door width for single doors; one inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors.

Provide a minimum 36 inch armor plates for flush doors. Provide 6 inch mop plates.

2.3.9 Door Stops and Silencers

ANSI/BHMA A156.16 . Silencers Type L03011. Provide three silencers for each single door, two for each pair.

2.3.10 Thresholds

ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.

2.3.11 Weather Stripping Gasketing

Provide weather stripping with one of the following:

2.3.11.1 Extruded Aluminum Retainers

Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear anodized aluminum.

2.3.12 Soundproofing Gasketing

BHMA A156.22 . Include adjustable doorstops at head and jambs and an automatic door bottom per set, both of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed-cell sponge gasket. Furnish door bottoms with adjustable operating rod and silicone rubber or closed-cell sponge neoprene gasket. Doorstops mitered at corners. Provide the type and function designation where specified in paragraph entitled "Hardware Sets".

2.3.13 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, required to service and adjust hardware items.

SECTION 08 71 00 Page 5

2.4 FASTENERS

Provide fasteners of proper type, quality, size, quantity, and finish with hardware. Provide stainless steel or nonferrous metal fasteners that are exposed to weather. Provide fasteners of type necessary to accomplish a permanent installation.

2.5 FINISHES

ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish except where BHMA 630 is specified under paragraph entitled "Hardware Sets". Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.

2.6 KEY CABINET AND CONTROL SYSTEM

ANSI/BHMA A156.5 , Type required to yield a capacity (number of hooks) 25 percent greater than the number of key changes used for door locks.

PART 3 EXECUTION

3.1 INSTALLATION

Install hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.

Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weather Stripping Installation

Handle and install weather stripping to prevent damage. Provide full contact, weather-tight seals. Operate doors without binding.

3.1.1.1 Stop-Applied Weather Stripping

Fasten in place with color-matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.

3.1.2 Soundproofing Installation

Install as specified for stop-applied weather stripping.

3.1.3 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves.

SECTION 08 71 00 Page 6

3.2 FIRE DOORS AND EXIT DOORS

Install hardware in accordance with NFPA 80 for fire doors, NFPA 101 for exit doors.

3.3 HARDWARE LOCATIONS

SDI/DOOR A250.8 , unless indicated or specified otherwise.

a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.

b. Mop Plates: Bottom flush with bottom of door.

3.4 KEY CABINET AND CONTROL SYSTEM

Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Furnish complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.

3.5 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, as directed, errors in cutting and fitting and damage to adjoining work.

SECTION 08 71 00 Page 7

SECTION 08 71 00 Page 8

3.6 HARDWARE SETS

Set: 1.0 Doors: 386, 395

Description: MAN TRAP - STC50 // RF shielded - EAC - CDX-10

3 Hinge, Cam Lift* MKCL180 US32D MK

1 Electric Power Transfer EL-CEPT 630 SU

1 High Security Exit Device* LKM10K (TO SUIT)

1 SFIC Core - 7-Pin Match base standard 626

1 Surface Closer (C02011 / C02021) 3501 R/PA SN-134 (To Suit) 689 YA

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO

1 STC Gasketing BY STC door mfg OT

1 Relay RLP-24 SU

1 Frame Harness QC-C1500P MK

1 Door Harness QC-C___ MK

1 Position Switch (E08)* By access control - Prep by D/F mfg SU

1 Card Reader BY SECURITY INTEGRATOR

1 Power Supply* AQDxx (TO SUIT) SU

Notes: Verify hardware requirements with STC door mfg.

RF shielding by door mfg Doors are normally locked and secured.

Presenting a valid credential releases the lever to allow free entry, door relocks upon closing, second door remains locked untill door #1 relocks. Door #2 3, unlocks at this point, relocks upon closing.

System reverses from other direction.

Relay board controls the locking / unlocking of the 3 doors.

Entry by key override at all times Doors is fail secure

Set: 2.0 Doors: 386A, 395A

Description: MANTRAP - EAC // STC50

1 Exit Device (Type 1, E01, E06) 7100 B AU691F Temp Core 630 YA

1 Cylinder Housing (E09251 / E09261) K660 626 YA

1 SFIC Core - 7-Pin Match base standard 626

1 Surface Closer (C02021- 3531 689 YA https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975319,211975297, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=147153279, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212032628, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873932, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975380,211975385, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954233, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954242, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975079,211975085, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975319,211975297, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212033712,212033033, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212034638,212034898, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=147153279, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212032628, SECTION 08 71 00 Page 9

PT4G)

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO

1 STC Gasketing BY STC door mfg OT

1 Relay RLP-24 SU

1 Frame Harness QC-C1500P MK

1 Door Harness QC-C___ MK

1 Position Switch (E08)* By access control - Prep by D/F mfg SU

Notes: Hardware listed for design criteria, confirm with specific door manufacturer the hardware requirements to meet specified windstorm rating - Provide 3rd party test results for confirmation.

Doors are normally locked and secured.

Presenting a valid credential releases the lever to allow free entry, door relocks upon closing, second door remains locked untill door #1 relocks. Door #2 3, unlocks at this point, relocks upon closing.

System reverses from other direction.

Relay board controls the locking / unlocking of the 3 doors.

Set: 3.0 Doors: 387, 396

Description: CONF / MANTRAP - EAC // STC50

1 Fail Secure Lock (E01, E06) AUR 8891FL Temp Core REX 626 YA

1 SFIC Core - 7-Pin Match base standard 626

1 Surface Closer (C02021-PT4G) 3531 689 YA

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO

1 STC Gasketing BY STC door mfg OT

1 Relay RLP-24 SU

1 Frame Harness QC-C1500P MK

1 Door Harness QC-C___ MK

1 Position Switch (E08)* By access control - Prep by D/F mfg SU

Notes: Hardware listed for design criteria, confirm with specific door https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873932, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975380,211975385, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954233, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954242, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975079,211975085, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975319,211975297, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212034153,212034118,212032394, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=147153279, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212032628, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873932, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975380,211975385, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954233, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954242, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975079,211975085, SECTION 08 71 00 Page 10 manufacturer the hardware requirements to meet specified windstorm rating - Provide 3rd party test results for confirmation.

Doors are normally locked and secured.

Presenting a valid credential releases the lever to allow free entry, door relocks upon closing, second door remains locked untill door #1 relocks. Door #2 3, unlocks at this point, relocks upon closing.

System reverses from other direction.

Relay board controls the locking / unlocking of the 3 doors.

Set: 4.0 Doors: 387A

Description: CONF - STC50 // RF shielded - EO

1 Exit Device (Type 1, 01) LKM10K EO 630 YA

1 Surface Closer (C02011 / C02021) 3501 R/PA SN-134 (To Suit) 689 YA

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO

1 STC Gasketing BY STC door mfg OT

1 Position Switch (E08)* By access control - Prep by D/F mfg SU

Notes:

Set: 5.0 Doors: 383

Description: MECH ROOM - STC50 // RF shielded

1 Fail Secure Lock (E01, E06) AUR 8891FL Temp Core REX 626 YA

1 SFIC Core - 7-Pin Match base standard 626

Surface Closer (C02011 / C02021) 3501 R/PA SN-134 (To Suit) 689 YA

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO

1 STC Gasketing BY STC door mfg OT

1 Frame Harness QC-C1500P MK

1 Door Harness QC-C___ MK

1 Position Switch (E08)* By access control - Prep by D/F mfg

SU

1 Card Reader BY SECURITY INTEGRATOR https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.lockmasters.com/lkm10k-panic-abr-retrofit-kit-with-2-strike https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212032628, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873932, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975319,211975297, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212034153,212034118,212032394, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=147153279, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212032628, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873932, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954233, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954242, SECTION 08 71 00 Page 11

Set: 6.0 Doors: 388

Description: BREAK - STC50

1 Passage Latch (F01) AUR 8801FL 626 YA

1 Surface Closer (C02011 / C02021) 3501 R/PA SN-134 (To Suit) 689 YA

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 STC Gasketing BY STC door mfg OT

Set: 7.0 Doors: 381A, 382A, 384A, 384B, 385, 391, 392, 393

Description: ENTRY - EAC - STC50 - EAC

1 Fail Secure Lock (E01, E06) AUR 8891FL Temp Core REX 626 YA

1 SFIC Core - 7-Pin Match base standard 626

1 Surface Closer (C02011 / C02021)

3501 R/PA SN-134 (To Suit) 689 YA

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO

1 STC Gasketing BY STC door mfg OT

1 Frame Harness QC-C1500P MK

1 Door Harness QC-C___ MK

1 Position Switch (E08)* By access control - Prep by D/F mfg SU

Set: 8.0 Doors: 382, 389

Description: STOR - STC50

1 Storeroom Lock (F07) AUR 8805FL Temp Core 626 YA

1 SFIC Core - 7-Pin Match base standard 626

1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO

1 STC Gasketing BY STC door mfg OT https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975079,211975085, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212034149,212033928,212032394, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212032628, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212034153,212034118,212032394, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=147153279, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212032628, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873932, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954233, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954242, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975079,211975085, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212034149,212033944,212032394, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=147153279, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873932, SECTION 08 71 00 Page 12

Set: 9.0 Doors: 387B

Description: CONF - STC50 - EO

1 Exit Device (Type 1, 01) - Alarm 7100 A EO 630 YA

1 Surface Closer (C02011 / C02021) 3501 R/PA SN-134 (To Suit) 689 YA

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO

1 STC Gasketing BY STC door mfg OT

1 Position Switch (E08)* By access control - Prep by D/F mfg SU

Notes: Alarm sound when pushbar is depressed, alarm sounds locally until turned off by a key. Alarm can be deactivated by key to allow for free egress.

-- End of Section --https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168612583, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211954303, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212033712,212033033, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212032628, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873932, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975347,

08 71 00
08 71 00_a Eglin AFB - DTRA Renovation - Bldg 13A - Door_Hardware_Schedule_2025-05-27

File details come from the government source that posted it. Updated .