The document is an architectural drawing (A-310) detailing wall sections and plan details for the DTRA Renovation project on the 3rd floor of Building 13A at Eglin Air Force Base, Florida. The drawing provides technical specifications for security wall construction, including:

Key technical specifications include 3 5/8" 16Ga galvanized metal studs at 16" on center, two layers of 5/8" gypsum wallboard, RF shielding, acoustical sealant, and sound insulation. The wall types are designed for Sound Group 4 with a minimum Sound Transmission Class (STC) of 50, and are compliant with ICS 705 and UFC-4-010-05 standards. The drawing includes details for wall sections, column enclosures, control joints, and specific requirements for secure areas like SCIF (Sensitive Compartmented Information Facility) spaces, with particular attention to sound isolation, RF shielding, and construction techniques for secure environments.

View the file

Other files

File Type Posted
04 20 00.pdf PDF
08 71 00.pdf PDF
06 41 16.00 10.pdf PDF
AD-101 DEMOLITION PLAN.pdf PDF
A-110 NEW WORK REFLECTED CEILING PLAN.pdf PDF
DTRA 13A 3rd Floor RFIs_all_Contracting_FINAL.docx DOCX document
A-311 WALL SECTIONS.pdf PDF
EGLIN EMCS AND-OR DDC SYSTEM REQUIREMENTS.pdf PDF
A-312 WALL SECTIONS.pdf PDF
22 00 00.pdf PDF
Addendum 1 _DTRA Renovation 3rd Floor Bldg 13a.docx DOCX document
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

KEYNOTES:

3 5/8" 16Ga GALVANIZED STUD TRACK SET IN 2 BEADS ACOUSTICAL SEALANT

RUBBER WALL BASE, SEE FINISH SCHEDULE SHEET I-601.

2' X 2' X 3/4" THICK LAY-IN ACOUSTICAL CEILING TILE AND GRID SYSTEM, TYPICAL.

SEE FINISH SCHEDULE SHEET I-601. GYPSUM WALLBOARD CEILING AT COMM

ROOMS 382 AND 382A.

ACOUSTICAL SEALANT, CONTINUOUS EACH SIDE, TOP AND BOTTOM OF WALL

EXISTING CONCRETE DECK

EXISTING FLOOR SLAB

(2) LAYERS 5/8" GYPSUM WALL BOARD, EXTEND TO EXISTING CONCRETE

STRUCTURE ABOVE WITH ACOUSTICAL SEALANT AT FLOOR AND CONCRETE DECK

ABOVE. FIRST LAYER SHALL BE TAPED AND MUDDED BUT NOT FINISHED. SECOND

LAYER SHALL BE TAPED AND MUDDED AND FINISHED CONTINUOUS TO UNDERSIDE

OF EXISTING CONCRETE STRUCTURE ABOVE AND SEAL. ALL JOINTS SHALL BE

STAGGERED ON BOTH LAYERS.

3 1/2" SAFB INSULATION WHERE INDICATED

EXISTING CONCRETE COLUMN

2 1/2" 16Ga GALVANIZED METAL STUDS

3 5/8" 16Ga GALVANIZED METAL STUDS @ 16" O.C.

14 FRICTION FIT SAFB, FILL CAVITY COMPLETELY

EXISTING WALL CONSTRUCTION

rFOIL SHIELDING (PERFORATED), WRAP AT FLOOR AND SECURE GYPSUM BOARD

CEILING ABOVE. LAP 8" MIN. PROVIDE CONT. RF SHIELDING OVER EXISTING

CONCRETE DECK INSIDE SECURE BOUNDARY.

15 GALVANIZED UNISTRUT SYSTEM (1 5/8" X 1 5/8" 12 GA. P1000) AT 24"

ATTACHED TO GYPSUM BOARD CEILING STUD JOISTS. SECURE W/ 1/4"

HEX WASHER HEAD SCREWS AT EACH JOIST

16 MITEK RT/S7A S/2.5 W/ (2) 3/16" x1" EMBEDMENT TAPCON ANCHOR TO CONCRETE

JOIST & #10 SCREWS TO LTGA JOIST, @EA. INTERSECTION

17 (2) LAYERS 5/8" GYPSUM WALL BOARD, SECURE TO UNDERSIDE OF CEILING JOIST

FRAMING. FIRST LAYER SHALL BE TAPED AND MUDDED BUT NOT FINISHED.

SECOND LAYER SHALL BE TAPED AND MUDDED AND FINISHED CONTINUOUS,

SEAL. ALL JOINTS SHALL BE STAGGERED ON BOTH LAYERS.

3 5/8" 16Ga GALVANIZED METAL STUDS @ 16" O.C.18

A-310

3"=1'-0"

SECURITY WALL SECTION

PER ICS 705 WALL TYPE "A" -SOUND GROUP 4

STC 50 (MIN)

WALL TYPE - W1

A-310

3"=1'-0"

TYPICAL COLUMN ENCLOSURE

A-310

3"=1'-0"

PLAN DETAIL

THIRD FLOOR

COMM/

ELEC

SECURE

ROOM

A-310

3"=1'-0"

SECURITY WALL SECTION

PER ICS 705 WALL TYPE "A" -SOUND GROUP 4

STC 50 (MIN)

WALL TYPE (RF SHIELDED) - W2

THIRD FLOOR

181217

CORR.

EXIST. CORR.

E379

A-310

3"=1'-0"

SECURITY WALL SECTION

PER ICS 705 WALL TYPE "A" -SOUND GROUP 4

STC 50 (MIN)

W3

THIRD FLOOR

181217

SCIF

E396

EXIST.

SHARED VAULT

E397

WALL TYPE (RF SHIELDED) -

16 16

'-0

'-0

'-0

ACOUSTICAL SEALANT

CONTROL JOINT

ACOUSTICAL SEALANT (FIRE

CAULK AT RATED ASSEMBLIES)

CONTROL JOINT (30'-0" MAX.)

SOUND INSULATION

COMPRESSED TO FIT OPENING

METAL STUD FRAMING

GYPSUM WALLBOARD AS

REQUIRED BY WALL ASSEMBLY RF SHIELDING

1/2"

UNCONTROLLED

SIDE

CONTROLLED SIDE

A-310

3"=1'-0"

CONTROL JOINT DETAIL

A-310

WALL SECTIONS AND PLAN DETAILS

BWA

SCALE: 3" = 1'-0"

2" 4"0 8"

96 CEG, OFFICE FORM 002, FY2013

AS-BUILT

PDM

REVISION DATE DESCRIPTION BY APPR'D

23AJ FTFA23-VH79 23AJ

23 OCT. 2024

AS SHOWN

DTRA RENOVATION

3RD FLOOR BLDG 13A

BASE CIVIL ENGINEER EGLIN

AIR FORCE BASE, FLORIDA

BWA

CONSTRUCTION WILL BE IAW

ICD/IDS 705 AND UFC-4-010-05

NOTE:

1 05/22/25 RFI ADJUSTMENTS KRW PDM

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SIGNATURE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

CENM

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

PROJ. ENGR.

AutoCAD SHX Text

CONTENTS

AutoCAD SHX Text

TITLE

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

INDEX NO.

AutoCAD SHX Text

PROJ. NO.

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

96 CEG/CEN

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

BASE CIVIL ENGINEER

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

FILE NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

SHEET OF

Sheets and Views
A-310