Legacy R22 Split HVAC System PowerPoint.pptx
PPTX presentation 9 MB Posted
- Attached to
- Legacy R22 Split System Replacement
- Solicitation number
- F2M3CB6061A003
About this file
This is a PowerPoint presentation providing technical specifications and visual documentation of a Legacy R22 Split HVAC System being replaced at JBSA Lackland. The presentation contains detailed component information and imagery for the existing system, which consists of a 15-ton direct expansion (DX) split system comprising a Rheem Air-Cooled Condensing Unit (Model No. RAWE-180CAZ, Serial No. 6698F010904536) and a RUUD Air Handling Unit (Model No. RHCE-150ZK, Serial No. 114G029900259). The system currently operates on the phased-out R-22 refrigerant and requires complete decommissioning and removal as part of the overall replacement project.
The presentation includes multiple technical images and diagrams of the condenser unit, air handler components, and control systems, along with specifications for the controller and breaker assembly. This documentation serves as a reference guide for the Sources Sought Notice (Solicitation Number F2M3CB6061A003) issued by the 502d Civil Engineer Squadron at the Department of the Air Force Air Education and Training Command. Prospective contractors responding to this pre-solicitation market inquiry should reference this technical information when evaluating their capability to provide replacement of the legacy system with a new, code-compliant 15-ton HVAC system equipped with modern Direct Digital Controls (DDC) and BACnet-compatible building automation capabilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Request for Information_Legacy R22 Split System Replacement.docx | DOCX document | |
| Request for Information_Legacy R22 Split System Replacement.docx | DOCX document | |
| Request for Information_Legacy R22 Split System Replacement.docx | DOCX document | |
| Legacy R22 Split HVAC System PowerPoint.pptx | PPTX presentation | |
| DRAFT Salient Characteristics_15-Ton Commercial DX Split System.docx | DOCX document | |
| DRAFT SOW_ Legacy R22 Split System Replacement B4983.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Legacy R22 Split HVAC System
RHEEM CONDENSER
RHEEM CONDENSER CONT.
RHEEM CONDENSER CONT.
RUUD AIR HANDLER
RUUD AIR HANDLER CONT.
RUUD AIR HANDLERCONT.
CONTROLLER & BREAKER
image1.png image2.png image3.png image4.png image5.png image6.png image7.png image8.png image9.png image10.png image11.png image12.png image13.png image14.png image15.png image16.png image17.png image18.png image19.png
File details come from the government source that posted it. Updated .