Exhibit N - Construction Environmental Safety Health Certification.pdf

PDF 541 KB Posted

Attached to
MI-65 Transfer Piping
Solicitation number
ISD-366397-RO
Issued by

About this file

This document is a Construction Environmental, Safety & Health Certification (CESHC) template for construction projects at the Department of Energy's Fermi National Accelerator Laboratory. The certification requires subcontractors to comply with 10 CFR 851 Worker Safety and Health Program regulations, which includes completing medical surveillance requirements for employees working on-site for 30 eight-hour days in a 12-month period or enrolled in any medical or exposure monitoring program. The document requires subcontractors to provide detailed medical qualification information, including clinic contact details, required medical surveillance tasks, and specific tasks necessitating medical monitoring.

The template is designed to be a living document that can be updated throughout a project, with subcontractors required to submit the completed CESHC to the FermiForward Procurement Office for review and concurrence by the ES&H and Project Management teams before work commences. The document provides a map of five identified medical facilities near Fermilab and requires subcontractors to select and annotate their designated medical facility, ensuring comprehensive occupational health coverage for workers at the site.

View the file

Other files

File Type Posted
MI-65 Transfer Piping _ Addendum 1.pdf PDF
Amendment 2 - ISD-366397-RO.pdf PDF
Amendment 1 - ISD-366397-RO.pdf PDF
1. Request for Proposal - Read Me First.pdf PDF
Exhibit B2 - Drawings.pdf PDF
Exhibit C - 010010_General_Requirements.pdf PDF
Exhibit E - 013300_Submittals.pdf PDF
Exhibit R - Sample Subcontract.pdf PDF
Exhibit F - 014100_Quality_Requirements.pdf PDF
Exhibit H - 2025 Construction Insurance Requirements.pdf PDF
Exhibit I - Bond Bid FL-41.pdf PDF
Exhibit L - Statement of Acknowledgment (SF-1413).pdf PDF
Exhibit P - Proposal Certifications Form PUR-466_FFDG.pdf PDF
Exhibit S - Sitemap.pdf PDF
Exhibit B1 - Statement of Work - MI-65 Transfer Piping.pdf PDF
Exhibit B3 - WELDING PROCEDURE SPECIFICATION.pdf PDF
Exhibit G - FFDG General Terms and Conditions for Construction (01.2025).pdf PDF
Exhibit J - Bond Payment FL-42.pdf PDF
Exhibit K - Bond Performance FL-40.pdf PDF
Exhibit M - Fermilab Subcontractor Safety Information Questionnaire.pdf PDF
Exhibit A - Price Proposal Form Construction.pdf PDF
Exhibit D - 013100_ESH_Requirements.pdf PDF
Exhibit O - SARC_Subcontractor Annual RepsCerts Rev 4_FFDG.pdf PDF
Exhibit Q - Wage Determination.pdf PDF
Exhibit T - Summary of Required RFP Submittal Documents.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

m.

ATTACHMENT C – Construction Environmental, Safety, & Health Certification (CESHC)

INSTRUCTIONS

This Construction Environmental, Safety & Health Certification (CESHC) is required for each construction project at DOE’s Fermi National Accelerator Laboratory site (Fermilab). See Technical Specification 013100 for further information.

This document is a template for the CESHC designed to assist construction subcontractors in describing project conditions and developing project-specific hazards and controls information.

The CESHC template is available in electronic format to facilitate editing.

The prime subcontractor may either flow down this requirement to each of its subcontractors; or serve as a control and coordination point, requiring all subcontractors’ activities to be conducted under the prime subcontractor’s solitary CESHC.

Subcontractors must submit the completed CESHC to the FermiForward Procurement Office, which will distribute the document for review and concurrence by the FermiForward ES&H and Project Management teams prior to work commencing. The CESHC is intended to be a living document, which may be updated as necessary throughout a project as information changes or as the project progresses (e.g. – as additional Task/trade Hazard Analyses are developed, subcontractors added, etc.).

All of the sections in are required to be completed for each construction project, regardless of the size or complexity. Enter information in all of the fill-in blocks that are applicable. For those that are not applicable, enter “N/A” or other suitable explanation.

10 CFR 851 Acknowledgement

Because Fermilab is a Department of Energy site, your company must meet the Department of Energy requirements of Title 10, Code of Federal Regulations, Part 851, “Worker Safety and Health Program” (Link to 10 CFR 851). It is your responsibility to ensure you have read and understand the actual regulatory requirements. Specify medical surveillance and qualifications. This may include Occupational exposure monitoring.

https://www.gpo.gov/fdsys/granule/CFR-2012-title10-vol4/CFR-2012-title10-vol4-part851

Construction Environmental, Safety & Health Certification (CESHC)

ACKNOWLEDGMENT of 10 CFR 851

As a subcontractor to FermiForward, while your workers are physically located at Fermilab you must meet the requirements of Title 10, Code of Federal Regulations, “Energy”, Part 851, “Worker Safety and Health Program” (10 CFR 851). As such, you must be aware of, and comply with, the requirements of this regulation. (Link to 10 CFR 851)

Acknowledgment I, (the author of this CEHSC), certify that that I have read the requirements of 10 CFR 851 and attest that my firm and its sub-tier contractors will comply with the requirements of 10 CFR 851.

Yes No

MEDICAL SURVEILLANCE AND

QUALIFICATION

Occupational Medicine Will you have any employees that will work on-site at Fermilab for 30, eight-hour days in a 12-month period, or are enrolled for any length of time in a medical or exposure monitoring program required by federal, state, or local regulations (including hearing conservation, respiratory protection, lead exposure)?

Yes No

If yes, you will need to:

1. Comply with the occupational medicine requirements of 10 CFR 851, Appendix A

2. Provide your occupational medicine provider contact information

Clinic Information Clinic Name & Address: Enter telephone number: Enter e-mail address: (Optional)

Required Medical Surveillance Task-specific medical testing

DOT/Commercial Vehicle Blood Lead Hearing Conservation Respirator User Fit for Duty Other(s) List other(s) Substance Abuse Testing

List specific task(s) requiring medical surveillance:

Signature (Subcontractor) Dated Signature

(FermiForward) Dated https://www.gpo.gov/fdsys/granule/CFR-2012-title10-vol4/CFR-2012-title10-vol4-part851

FermiForward has identified five medical facilities. Please highlight the facility to be used or identify and provide a map of an alternate selected place. Annotate address for designated facility.

i.