Exhibit B3 - WELDING PROCEDURE SPECIFICATION.pdf

PDF 87 KB Posted

Attached to
MI-65 Transfer Piping
Solicitation number
ISD-366397-RO
Issued by

About this file

This document is a Welding Procedure Specification (WPS) from Fermi National Accelerator Laboratory's Technical Division-Machine Shop, detailing the precise welding parameters for a specific welding process. The specification covers technical details for GTAW (Gas Tungsten Arc Welding) on stainless steel materials (SA 213-07a Type 304/304L), including joint design, base metals, filler metals, welding positions, and process characteristics. Key specifications include a V groove-open root joint design, welding in the 6G upward position, using argon gas for shielding and backing, with a preheat temperature of 32°F and interpass temperature of 350°F.

The WPS outlines specific technical requirements such as a single electrode welding technique, initial cleaning with alcohol solvent, multi-pass welding, and using a Dynasty DX #4172 power source with remote foot pedal control. Filler metal specifications include 308/308L class metals with diameters of 0.045" and 1/16", and electrical characteristics of DC current with non-pulsing characteristics. The document includes a warning that the WPS is subject to change and the current version is maintained on the laboratory's technical division website.

View the file

Other files

File Type Posted
Amendment 2 - ISD-366397-RO.pdf PDF
MI-65 Transfer Piping _ Addendum 1.pdf PDF
Amendment 1 - ISD-366397-RO.pdf PDF
Exhibit A - Price Proposal Form Construction.pdf PDF
Exhibit D - 013100_ESH_Requirements.pdf PDF
Exhibit O - SARC_Subcontractor Annual RepsCerts Rev 4_FFDG.pdf PDF
Exhibit Q - Wage Determination.pdf PDF
Exhibit T - Summary of Required RFP Submittal Documents.pdf PDF
Exhibit F - 014100_Quality_Requirements.pdf PDF
Exhibit H - 2025 Construction Insurance Requirements.pdf PDF
Exhibit I - Bond Bid FL-41.pdf PDF
Exhibit L - Statement of Acknowledgment (SF-1413).pdf PDF
Exhibit P - Proposal Certifications Form PUR-466_FFDG.pdf PDF
Exhibit S - Sitemap.pdf PDF
Exhibit B1 - Statement of Work - MI-65 Transfer Piping.pdf PDF
Exhibit G - FFDG General Terms and Conditions for Construction (01.2025).pdf PDF
Exhibit J - Bond Payment FL-42.pdf PDF
Exhibit K - Bond Performance FL-40.pdf PDF
Exhibit M - Fermilab Subcontractor Safety Information Questionnaire.pdf PDF
1. Request for Proposal - Read Me First.pdf PDF
Exhibit B2 - Drawings.pdf PDF
Exhibit C - 010010_General_Requirements.pdf PDF
Exhibit E - 013300_Submittals.pdf PDF
Exhibit N - Construction Environmental Safety Health Certification.pdf PDF
Exhibit R - Sample Subcontract.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

“WARNING: This WPS is subject to change. The current version is maintained on the TD website: http://www-tdserver1.fnal.gov/tdweb/ms/Policies/Welding/.”

PURGE GAS OXYGEN CONTENT: 25 PPM