Exhibit E - Architectural Drawings.pdf
PDF 11 MB Posted
- Solicitation number
- RFP202690000697
- Issued by
- Mingo County, West Virginia
About this file
This file contains architectural drawings and code compliance documentation for a renovation project at West Virginia University's Evansdale Crossing facility located at 62 Morrill Way in Morgantown, West Virginia. The project involves renovations to the third and fourth floors of the existing five-story building to support a new testing center, associated offices, meeting rooms, and support spaces. The total building floor area is 102,342 square feet, with renovation work affecting approximately 12,280 square feet across the third and fourth floors. The building is classified as Type II(222) fully sprinklered construction with mixed occupancy classifications including business use and assembly use areas. The architectural drawings include existing condition plans, demolition plans, new work plans, reflected ceiling plans, and enlarged interior elevation details for restrooms and kitchen facilities.
The project must comply with multiple applicable codes including the West Virginia State Building Code and 2021 International Building Code, along with referenced standards for life safety (NFPA 101 2021 Edition), accessibility (ICC/ANSI A117.1-2017), energy (ASHRAE 90.1-2013), plumbing (IPC 2018), mechanical (IMC 2018), electrical (NEC 2017), and fire suppression (NFPA 13). Key code compliance requirements include a maximum travel distance of 300 feet from sprinklered areas, dead end limit of 50 feet, common path travel of 100 feet, and at least two means of egress required from each floor. The third floor renovation encompasses 11,729.18 square feet with a calculated occupancy load of 367 persons, while the fourth floor renovation affects 551.04 square feet. Wall assembly types include new and upgraded one-hour fire-rated partitions, and specific interior wall assemblies are detailed for construction. The drawings are marked as progress drawings not for construction and were prepared by Omni Associates, Architects in Fairmont, West Virginia, as of October 21, 2025.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING CODE:
• West Virginia State Building Code (Current Edition)
• International Building Code (2021 Edition)
LIFE SAFETY:
• West Virginia State Fire Code (Current Edition)
• NFPA 101 Life Safety Code (2021 Edition)
ACCESSIBILITY:
• ICC/ANSI A117.1-2017
ENERGY:
• ANSI/ASHRAE/IESNA Standard 90.1-2013
PLUMBING:
• NFPA 13 Standard for the Installation of Sprinkler Systems
• International Plumbing Code (2018 Edition)
MECHANICAL:
• NFPA 90A (HVAC) Mechanical
• international Mechanical Code (2018 Edition)
ELECTRICAL:
• NFPA 70 - National Electrical Code (2017 Edition)
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
G-1.0
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- C O
V E R
S H
E E T
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
C O N C E P T U A L A X O N O M E T R I C V I E W
WVU EVANSDALE CROSSING RENOVATION CODE REVIEW
QR CODE
co n ta ct i n fo
P R O J E C T L O C A T I O N
P R O J E C T I N F O R M A T I O N
Sheet
Number Sheet Name
GENERAL
G-1.0 COVER SHEET
G-1.1 EXISTING CONDITIONS CODE REFERENCE
G-1.2 CODE COMPLIANCE UN-ALTERED FIRST & SECOND FLOORS
G-1.3 CODE COMPLIANCE - NEW WORK THIRD & FOURTH FLOORS
G-1.4 CODE COMPLIANCE UN-ALTERED FIFTH FLOOR
ARCHITECTURAL
A-0.0 ASSEMBLY TYPES, NOTES, AND SYMBOLS
AE-1.3 EXISTING CONDITIONS PLAN - 3rd FLOOR
AE-1.4 EXISTING CONDITIONS PLAN - 4th FLOOR
AD-1.3 DEMOLITION PLAN - 3rd FLOOR
AD-1.4 DEMOLITION PLAN - 4th FLOOR
A-1.3 NEW WORK PLAN - 3rd FLOOR
A-1.3a NEW WORK PLAN - 3rd FLOOR - AREA A
A-1.3b NEW WORK PLAN - 3rd FLOOR - AREA B
A-1.4 NEW WORK PLAN - 4th FLOOR
A-1.4a NEW WORK PLAN - 4th FLOOR - AREA A
A-1.4b NEW WORK PLAN - 4th FLOOR - AREA B
A-1.13 REFLECTED CEILING PLAN - 3rd FLOOR
A-1.13a REFLECTED CEILING PLAN - 3rd FLOOR - AREA A
A-1.13b REFLECTED CEILING PLAN - 3rd FLOOR - AREA B
A-1.14 REFLECTED CEILING PLAN - 4th FLOOR
A-1.14a REFLECTED CEILING PLAN - 4th FLOOR
A-1.14b REFLECTED CEILING PLAN - 4th FLOOR
A-4.1 ENLARGED PLANS AND INTERIOR ELEVATIONS
Applicable Life Safety Code NFPA 101 LIFE SAFETY CODE 2021 ED.
Applicable International Building Code (IBC) IBC 2018 ED.
Floor Area of Renovation (if applicable) 12,280.22 SF
Floor Area of Addition (if applicable) N/A
Total Floor Area (SQ. FT.) 102,342 SF
Building Footprint Area 25,988 SF
Does this building have a basement? NO
Number of Stories above grade 5
(A-1, B, R-1, etc.) FULL
USE\ OCCUPANCY CLASSIFICATION(S): FIRE SUPRESSION:
RENOVATION (IA, IB, IIB, etc.)
TYPE OF WORK: TYPE(S) OF CONSTRUCTION:
MORGANTOWN WV 26506
62 MORRILL WAY WEST VIRGINIA UNIVERSITY
BUILDING ADDRESS: OWNER ADDRESS:
P R O J E C T T E A M
D R A W I N G I N D E X
= PROJECT LOCATION
(304) 367-1417
Fairmont, WV 26554
207 Jefferson Street
Omni Associates, Architects
ARCHITECTURAL SERVICES:
MORGANTOWN WV 26505
WEST VIRGINIA UNIVERSITY
OWNER:
REVISIONS ▼
Axon - 3rd Floor
A P P L I C A B L E C O D E S
WV-705 (PATTERSON DRIVE)
W V-7 (M
ONONGAHELA BLVD
W
V-7 (BEECHURST AVE)
M O
R R
IL W
A
Y
Axon - 4th Floor
Exhibit E - Architectural Drawings
ROOF
ROOF
105' - 0"
110' - 6"
142' - 0"
131' - 0" 146' - 6"
152' - 0"
OCCUPANT LOAD (TABLE 1004.1.1)
100 ppl @ 100 gross sf/person
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
G-1.1
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- E X
IS
TI
N G
C O
N D
IT
IO
N S C
O D
E R
E F E R
E N
C E
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
REVISIONS ▼
SCALE: 1/16" = 1'-0" SHEET: G-1.103 LIFE SAFETY PLAN - 03 THIRD FLOOR EXISTING CONDITIONS
ORIGINAL EVANSDALE CROSSINGS CODE INFORMATION (FOR REFERENCE)
UP
DN
DN
UP
DN
DN
UP
UP
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S02-1/1
DOOR
CLEAR
CAPACITYE
X
IT
100/4
DOOR
CLEAR
CAPACITYE
X
IT
100/3
DOOR
CLEAR
CAPACITYE
X
IT
100/2
DOOR
CLEAR
CAPACITYE
X
IT
100/1
ENTRY LOBBY
ELEVATOR LOBBY
STAIR 3
S03-1
ELEV
E1-1
ELEV
E2-1
ELEV
E3-1
F ELEV
E4-1
FIRE CMD CNTR
ELEC
STAIR 2
S02-1
2'-10"
2'-10"
2'-10"
2'-10"
1ST FLOOR GROSS AREA = 22,247 SF
MECHANICAL
CHASE
MECHANICAL
CHASE
STAIR 4
S04-1
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S03-2/1
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S01-2/1
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S01-2/2
STAIR 3
S03-1
F ELEV
E4-1
STAIR 1
S01-2
LOBBY
CORRIDOR
ELEC
SERVICE CORRIDOR
ELEV
E2-2
ELEV
E3-2
ELEV
E4-2
2ND FLOOR GROSS AREA = 25,988 SF
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
S02-2/1
MECHANICAL
CHASE
MECHANICAL
CHASE
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
EXIT ACCESS TRAVEL DISTANCE
100'-0"
FIRE EXTINGUISHER - CABINET
DOOR
CLEAR
CAPACITYE
X
IT
6' - 0"
EGRESS OPENING INDICATOR
WITH EGRESS CAPACITY TAG
FLOOR LEVEL
PATH OPTION
STAIR TOWER #
2A3
TRAVEL DISTANCE
AREA NOT IN SCOPE
ASSEMBLY OCCUPANCY
BUSINESS OCCUPANCY
STORAGE OCCUPANCY
OCCUPANCY LEGEND
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
G-1.2
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- C O
D E C
O M
P
LI
A N
C E U
N -A
LT
E R
E D
F
IR
S T
S
E C
O N
D F
LO
O
R S
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
REVISIONS ▼
SCALE: 1/16" = 1'-0" SHEET: G-1.21 LIFE SAFETY PLAN - 01 FIRST FLOOR
SCALE: 1/16" = 1'-0" SHEET: G-1.22 LIFE SAFETY PLAN - 02 SECOND FLOOR
CODE SYMBOLS LEGEND
DN
DN
DN
DN
UP
UP
UP
S
S
S
S
S
S
S
S
SA
115' - 0" 3C1
114' - 6" 3C3
140' - 6" 3B1
86' - 6" 3D2
153' - 6" 3A3 100' - 6" 3A1
STAIR 1
S01-3
TESTING CENTER
132' - 6" 3D3
138' - 6" 3B3
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S01-3/1
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S03-3/1
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
372/1
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
S02-3/1
CORR
C2
CORR
C2
LOBBY
300STAIR 3
S03-3
LOUNGE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MTG
OFFICE
W/C
KITCHEN
STO
314OFFICE
TESTING CENTER
TESTING CNTR
RCPTN
CORRIDOR
C305
F ELEV
E4-3
ELEV
E3-3
ELEV
E2-3
ELEV
E1-3 STORAGE
SHELL SPACE
MTG
ELEC
STAIR 2
S02-3
STAIR 5
S05-3
DOOR
CLEAR
CAPACITYE
X
IT
5'-10"
357/1
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
320-1
DOOR
CLEAR
CAPACITYE
X
IT
320-3
DOOR
CLEAR
CAPACITYE
X
IT
320-2
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
2'-10"
5'-8"
173' - 6" 3F1192' - 0"
3F3
ROOFROOF
EXISTING COVERED WALKWAY
G01
G02
G03
3RD FLOOR GROSS AREA = 21,733 SF
(AREA OF RENOVATION = 11,729.18 SF)
OCCUPANT LOAD (TABLE 1004.5)
5,416 sf 36 ppl @ 150 gross sf/person (was previously 100 gross sf/person (IBC 2009))
OCCUPANT LOAD (TABLE 1004.5)
948.56 sf 63 ppl @ 15 gross sf/person
OCCUPANT LOAD (TABLE 1004.5)
349 sf 1 ppl @ 300 gross sf/person
OCCUPANT LOAD (TABLE 1004.5)
2,262 sf 150 ppl @ 15 gross sf/person
OCCUPANT LOAD (TABLE 1004.5)
1,268 sf 8 ppl @ 150 gross sf/person
OCCUPANT LOAD (TABLE 1004.5) (CONCENTRATED)
368 sf 7 ppl @ 50 gross sf/person
OCCUPANT LOAD (TABLE 1004.5)
28 sf 0 ppl @ 150 gross sf/person
EX
IS
T
IN
G
EX
IS
T
IN
G
EX
IS
T
IN
G
EX
IS
T
IN
G
N E
W
G04
G04
G02
G02
G02
G01 G01
G02
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
371-2
CLASSROOM
DOOR
CLEAR
CAPACITYE
X
IT
371-1
2'-10"
(LIMITED TO
120 SEATS MAX)
(25-50 SEAT
CLASSROOM)
95' - 0" 3E3
90' - 0" 3E2
G05
COLLABORATION
CBCL
CBCL
LAUNCH LAB -
VACANT
STORAGE
VACANT
MTG
CBCL
CBCL
CBCL
CBCL
CBCL
CBCL
CBCL
CBCL
CBCL
CBCL
CBCL
CBCL
G02
G02
G06
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
373/1
66' - 6" 3G2
132' - 0" 3G3
MECHANICAL
CHASE
MECHANICAL
CHASE
47' - 6" 3H3
163' - 0" 3H2
OCCUPANT LOAD (TABLE 1004.5)
609.45 sf 4 ppl @ 150 gross sf/person (was previously 100 gross sf/person (IBC 2009))
ROOF
BEYOND
79' - 0" 4A3
164' - 0" 4A2
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S01-4/1
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S03-4/1
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
S02-4/1
STAIR 3
S03-4 LOBBY
CORRIDOR
F ELEV
E4-4
ELEV
E1-4
ELEV
E2-4
ELEV
E3-4
STAIR 1
S01-4
STAIR 2
S02-4
ELEC RM
4TH FLOOR GROSS AREA = 21,406 SF
(AREA OF RENOVATION = 551.04 SF)
MECHANICAL
CHASE
MECHANICAL
CHASE
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
400/3
OFFICE
CONF RM
OFFICE
PHONE
CIRC
CIR-42
OCCUPANT LOAD (TABLE 1004.5)
409.66 sf 2 ppl @ 150 gross sf/person
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
403/2
ROOF
BEYOND
ROOF
BEYOND
EXISTING COVERED
WALKWAY BEYOND
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
EXIT ACCESS TRAVEL DISTANCE
100'-0"
FIRE EXTINGUISHER - CABINET
DOOR
CLEAR
CAPACITYE
X
IT
6' - 0"
EGRESS OPENING INDICATOR
WITH EGRESS CAPACITY TAG
FLOOR LEVEL
PATH OPTION
STAIR TOWER #
2A3
TRAVEL DISTANCE
AREA NOT IN SCOPE
ASSEMBLY OCCUPANCY
BUSINESS OCCUPANCY
STORAGE OCCUPANCY
OCCUPANCY LEGEND
The footprint of plans submitted for review for code analysis of the Evansdale Crossing 3rd Floor. The building is existing Type II(222) fully sprinklered. This was evaluated from NFPA 101 Chapter 43 as Reconstruction.
The following Codes apply: WV State Fire Code 87 CSR 1 Effective Date July 1, 2016 2021 NFPA 101 (Life Safety) and NFPA codes in effect 2021 2017 NFPA 70 National Electric Code
2019 NFPA 13
2021 NFPA 90A (HVAC) Mechanical 2021 International Building Code adopted WV Effective August 8, 2022
College Business Occupancy:
Minimum Construction Type: 2024 WV STATE FIRE CODE
2021 IBC Chapter 5 Occupant Load: 2021 NFPA 101, 7.3.1.2
Assembly Use Area: 15 Business Use Area: 50 2021 IBC Chapter 10
Means of Egress: 2021 NFPA 101, 13.
Travel Distance 300 feet (sprinklered) Dead End Limit 50 feet (sprinklered) Common Path Travel 100 feet if build is (sprinklered) At least two means of egress are required from each floor
Vertical Openings: 3 STAIRS 2021 NFPA 101, Chapter 8 2 Hour Rating
Interior Finish 2021 NFPA 101, Exit corridors- Class A or B Exit Access Corridors.
Class A & B or C including ceilings and wall in all other areas.
Fire Alarm Requirements: WV State Fire Code 87-1 (2.2.1) Fire Alarm required for supervision of sprinkler system
Fire Extinguishers: 2021 NFPA 101, , NFPA 10, 75 feet travel distance
Sprinkler Requirements: Existing sprinklered WV State Fire Code 2021 IBC required to comply with building height and area
NFPA 101, 43.2.2.1.4 * Reconstruction.
The reconfiguration of a space that affects an exit or a corridor shared by more than one occupant space; or the reconfiguration of a space such that the rehabilitation work area is not permitted to be occupied because existing means of egress and fire protection systems, or their equivalent, are not in place or continuously maintained.
NFPA 101, 43.2.2.4 Rehabilitation Work Area.
That portion of a building affected by any renovation, modification, or reconstruction work as initially intended by the owner, and indicated as such in the permit, but excluding other portions of the building where incidental work entailed by the intended work must be performed, and excluding portions of the building where work not initially intended by the owner is specifically required.
BUSINESS WITH ASSEMBLY USE AREAS
12.1.3 Multiple Occupancies.
12.1.3.1 General.
Multiple occupancies shall be in accordance with 6.1.14.
12.1.3.3 * Simultaneous Occupancy.
Exits shall be sufficient for simultaneous occupancy of both the assembly occupancy and other parts of the building, except where the authority having jurisdiction determines that the conditions are such that simultaneous occupancy will not occur.
Occupancy
Assembly ≤ 300
Assembly >300 to ≤1000
Assembly >1000
Educational
Apartment Buildings
Board & Care Small
Board & Care Large
Mercantile
Mercantile, Mall
Mecantile, Bulk, Retail
Business
Industrial, General Purpose
Industrial, Special Purpose
Industrial, High
Hazard
Storage, Low &
Ordinary Hazard
Storage, High
Hazard
Table 6.1.14.4.1(b) Required Separation of Occupancies (hours)*, Part 2
*Minimum Fire Resistance Rating. The fire resistance rating is permitted to be reduced by 1 hour, but in no case to less than 1 hour, where the building is protected throughout by an approved automatic sprinkler system in accordance with 9.7.1.1(1) and supervised in accordance with 9.7.2.
If the Assembly Occupancy is part of the adjacent business area this could be considered incidental, and no separation would be required. If area is rented to another entity separation may be required.
Occupant Load.
The occupant load, in number of persons for whom means of egress and other provisions are required, shall be determined on the basis of the occupant load factors that are characteristic of the use of the space or shall be determined as the maximum probable population of the space under consideration, whichever is greater.
All office areas occupant load shall be determined using 50 square feet per person.
Calculated Business square footage 7661 / 50 = 153.22 persons Calculated Assembly Use Room 320 2262 / 15= 150.8 persons Calculated Assembly Use Room 371 948 / 15= 63.2 persons
STORAGE AREAS
*other than Storage and Mercantile Occupancy 715 / 500= 1
TOTAL OCCUPANCY THIRD FLOOR = 367 PERSONS
Stair 1 Door S01 40” / .2 = 200 PERSONS Stair 2 Door S02 3/1 34” / .2 = 170 PERSONS Stair 3 Door S03-3/1 40” / .2 = 200 PERSONS Stair width 44 inches 44”/.3 = 147 PERSONS PER STAIR 147x3 = 441 PERSONS
Door 320-1 from Assembly Area 34” /.2= 170 Persons Door 320-2 from Assembly Area 34” /.2= 170 Persons Door 320-3 from Assembly Area 34” /.2= 170 Persons Doors 320-2 and 320-3 are not remote
Door 357-1 Double Egress 70” /.2 = 350 Persons
Classroom 371 Door 371-1 34” /.2=170 Persons Door 371-2 34” /2=170 Persons
4th Floor renovation of 3 Office space reveals no requirements.
1. Exiting for all areas have required width for Occupancy Load Calculations
2. Travel Distance for all areas are within code requirements.
3. Electrical Room 306 shall be at least smoke tight with 20 minute rated door, closer, and latch unless the room has a transformer room with greater than 125 kVA require fire rated separation according to the National Electric Code of at least 1-hour with a ¾ hour rated door and assembly.
NFPA 80, 5.2 * Inspection and Testing.
5.2.1 * Upon completion of the installation, door, shutters, and window assemblies shall be inspected and tested in accordance with 5.2.4.
NFPA 80, 5.2.2.1
Records of acceptance tests shall be retained for the life of the assembly.
NFPA 101, 12.2.2.2.1
Doors complying with 7.2.1 shall be permitted.
7.2.1.14 Inspection of Door Openings.
7.2.1.14.1 * Where required by Chapters 11 through 43, the following door assemblies shall be inspected and tested not less than annually in accordance with 7.2.1.14.2 through 7.2.1.14.7:
1. (1) Door leaves equipped with panic hardware or fire exit hardware in accordance with 7.2.1.7
2. (2) Door assemblies in exit enclosures
3. (3) Door hardware release of electrically locked egress door assemblies
4. (4) Door assemblies with special locking arrangements subject to 7.2.1.6
7.2.1.14.2 * The inspection and testing interval for fire-rated and nonrated door assemblies shall be permitted to exceed 12 months under a written performance-based program.
7.2.1.14.2.2
Technical justification for inspection, testing, and maintenance intervals shall be documented.
7.2.1.14.3 A written record of the inspections and testing shall be signed and kept for inspection by the authority having jurisdiction.
7.2.1.14.4 Functional testing of door assemblies shall be performed by individuals who can demonstrate knowledge and understanding of the operating components of the type of door being subjected to testing.
7.2.1.14.5 Door assemblies shall be visually inspected from both sides of the opening to assess the overall condition of the assembly.
7.2.1.14.6 As a minimum, the following items shall be verified:
1. (1) Floor space on both sides of the openings is clear of obstructions, and door leaves open fully and close freely.
2. (2) Forces required to set door leaves in motion and move to the fully open position do not exceed the requirements in 7.2.1.4.5.
3. (3) Latching and locking devices comply with 7.2.1.5.
4. (4) Releasing hardware devices are installed in accordance with 7.2.1.5.3.1.
5. (5) Door leaves of paired openings are installed in accordance with 7.2.1.5.9.
6. (6) Door closers are adjusted properly to control the closing speed of door leaves in accordance with accessibility requirements.
7. (7) Projection of door leaves into the path of egress does not exceed the encroachment permitted by 7.2.1.4.3.
8. (8) Powered door openings operate in accordance with 7.2.1.9.
9. (9) Signage required by 7.2.1.4.1(3), 7.2.1.5.6, 7.2.1.6, and 7.2.1.9 is intact and legible.
10. (10) Door openings with special locking arrangements function in accordance with 7.2.1.6.
11. (11) Security devices that impede egress are not installed on openings, as required by 7.2.1.5.10.
12. (12) Where required by 7.2.2.5.5.7, door hardware marking is present and intact.
13. (13) Emergency lighting on sensor-release of electrical locking systems and doors equipped with delayed-egress electrical locking systems is present in accordance with
Section 7.9.
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
G-1.3
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- C O
D E C
O M
P
LI
A N
C E
N E W
W O
R K
T H
IR
D
F
O U
R
TH
F
LO
O R
S
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
REVISIONS ▼
SCALE: 1/16" = 1'-0" SHEET: G-1.303 LIFE SAFETY PLAN - 03 THIRD FLOOR
SCALE: 1/16" = 1'-0" SHEET: G-1.304 LIFE SAFETY PLAN - 04 FOURTH FLOOR
CODE SYMBOLS LEGEND
EXIT ACCESS TRAVEL DISTANCE - 3RD FLOOR
Mark Length
3A1 100'-8"
3A3 153'-5"
3B1 140'-4"
3B3 138'-3"
3C1 115'-0"
3C3 114'-7"
3D2 86'-9"
3D3 132'-5"
3E2 90'-3"
3E3 94'-10"
3F1 173'-5"
3F3 192'-1"
3G2 66'-7"
3G3 132'-2"
3H2 163'-1"
3H3 47'-4"
KEYED MODIFICATION NOTES
# Note Text
G01 NEW 1 HOUR RATED PARTITION WALL
G02 UPGRADE EXISTING WALLS TO 1 HOUR RATED PARTITION WALL
G03 NEW 45 MIN RATED DOOR & FRAME IN UPGRADED 1 HOUR PARTITION WALL
G04 PANIC HARDWARE REQUIRED
G05 RELOCATED CUBICLE WALLS
G06 UPGRADE EXISTING DOOR, FRAME, AND HARDWARE AS REQUIRED TO ACHIEVE A
45 MIN RATED DOOR & FRAME IN UPGRADED 1 HOUR PARTITION WALL
EXIT ACCESS TRAVEL DISTANCE - 4TH FLOOR
Mark Length
4A2 164'-1"
4A3 78'-9"
CODE ANALYSIS
SA
DOOR
CLEAR
CAPACITYE
X
IT
3'-2"
S01-5/1
DOOR
CLEAR
CAPACITYE
X
IT
3'-4"
S03-5/1
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
509/2
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
509/1
DOOR
CLEAR
CAPACITYE
X
IT
2'-10"
550/1
172' - 6" 5A
84' - 0" 5B
EDGE OF EXISTING
PRT BUILDING
F ELEV
E4-5
ELEV RM
S03-28
ELEV
E1-5
ELEV
E2-5
ELEV
E3-5
STAIR 3
S03-5
STAIR 1
S01-5
BRIDGE
ROOF
CORRIDOR
LOBBY
5TH FLOOR GROSS AREA = 10,968 SF
67' - 0" 5C
OPEN ROOF
TERRACE
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
EXIT ACCESS TRAVEL DISTANCE
100'-0"
FIRE EXTINGUISHER - CABINET
DOOR
CLEAR
CAPACITYE
X
IT
6' - 0"
EGRESS OPENING INDICATOR
WITH EGRESS CAPACITY TAG
FLOOR LEVEL
PATH OPTION
STAIR TOWER #
2A3
TRAVEL DISTANCE
AREA NOT IN SCOPE
ASSEMBLY OCCUPANCY
BUSINESS OCCUPANCY
STORAGE OCCUPANCY
OCCUPANCY LEGEND
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
G-1.4
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- C O
D E C
O M
P
LI
A N
C E U
N -A
LT
E R
E D
F
IF
TH
F
LO
O
R
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
REVISIONS ▼
SCALE: 1/16" = 1'-0" SHEET: G-1.405 LIFE SAFETY PLAN - 05 FIFTH FLOOR
CODE SYMBOLS LEGEND
INTERIOR WALL ASSEMBLIES
E EXISITNG WALL TYPE (COMPOSITION TO BE FIELD
VERIFIED AS REQUIRED)
SF METAL STUD FULL-HEIGHT
SP METAL STUD PARTIAL-HEIGHT
SW SHAFT WALL
EXAMPLES:
SF1 = MTL STUD FULL-HEIGHT INT WALL ASSEMBLY, TYPE #1
SP3 = MTL STUD PARTIAL-HEIGHT INT WALL ASSEMBLY, TYPE #3
SEE ASSEMBLY LEGENDS (THIS SHEET) FOR ASSEMBLIES USED IN
THIS PROJECT
A. See plans and sections for wall, roof, and floor assembly location and type selections.
B. All U.L. rated systems shown or referenced in these construction documents shall be installed according to the specifications as shown in the current version of the official U.L. system reference tool, such as “U.L.
Product iQ”. U.L. systems are not fully detailed and therefore it is the contractor’s responsibility to reference the system to become fully aware of all the detailed requirements. To ensure compliance, the contractor is required to submit a shop drawing of each type of system showing details and components. Any alternative systems must be approved during the bidding process.
C. Wall types do not include finishes, U.N.O. See room finish schedule and \ or interior elevations for finish information.
D. All interior partition types shall be type 'SF1A' unless noted otherwise.
E. Walls surrounding tubs, adjacent to sinks and toilets or where wall tile is to be applied shall have moisture-resistant gypsum wallboard in lieu of GWB shown on wall types (match GWB thickness).
F. See code compliance sheet for location of walls of fire-resistive construction. All walls of fire-resistive construction shall extend to underside of floor or roof deck above. All rated walls are to be constructed in accordance with noted assembly designs to the standards of the applicable testing agency.
G. In all cases, the partition with the greater fire rating shall be continuous through wall intersections.
H. All penetrations through walls, floors and between curtainwall and floor shall be sealed with firestopping material as required to achieve the respective fire-resistive rating and smoke stoppage.
I. Fire rated enclosures around all steel columns shall be continuous from floor to underside of deck above for each level.
J. Provisions shall be made at all full height nonbearing walls for 1-inch vertical movement of the building structure without transfer of compressive loads to wall. Fill irregularities between top of wall land deck above with fire safing insulation or firestopping materials as required to meet fire rating of respective walls. See detail for stud walls and structural for CMU walls.
K. Scribe gypsum board of walls and partitions to irregularities of deck above.
Seal tightly around any penetrations.
L. Control joints in gypsum wall board to be spaced no more than 25'-0" apart, and are to be aligned to fenestration edges when possible.
M. Interior walls where sound batts are indicated are acoustic walls, and should be sealed accordingly. Maintain specific STC ratings where noted.
Walls enclosing restrooms and private offices shall always be insulated to prevent sound transmittance.
N. All partitions enclosing toilet rooms and mechanical rooms shall have sound insulation.
O. Where steel stud walls do not extend to structure, provide brace at centerline of door openings.
P. Wall types do not show blocking or bracing within the wall. The contractor is responsible for anticipating where blocking and bracing will be required to meet the design intent. Certain types of blocking (such as untreated wood) may not be allowed by code to be used in all types of construction.
Confirm with architect that planned blocking methods are acceptable.
Locations for blocking include, but are not limited to:
- wall-mounted counters and cabinets
- wall-mounted accessories and equipment
- door hold-open devices, closures and stops
- toilet room partitions and accessories
- televisions and mounting brackets
- other locations as required by architect and industry standards
A10
AA
AA
AA AA
A10
Ref BB
B B
BB
B B
A.1N
A.F.F.
ACT-5
8'-0" Level 1
S
Room name
150 SF
EXTERIOR
ELEVATIONS
DOOR TAG
WALL ASSEMBLY TAG
WINDOW TAG
GLAZING PANEL TYPE
CEILING TAG
BUILDING
SECTIONS
WALL & DETAIL
SECTIONS
SECTION
SHEET
STRUCTURAL
GRIDS
# KEYED NOTES
ELEV.
SPOT ELEVATION BUILDING LEVEL
ROOM TAG
MATERIAL TAG
PLAN NORTH
TRUE NORTH
NORTH
ARROW
PHOTO REFERENCE
Ref
Ref
ELEV.
NAME
CALLOUT REFERENCE
INTERIOR
ELEVATIONS
ELEVATION
SHEET
SECTION
SHEET
X TOILET ACCESSORIES
0"
+6"
ELEVATION CHANGE
A.1
EXISTING NEW
R1 ROOF or FLOOR
ASSEMBLY TAG
000.0 SIGNAGE TYPE
ELEVATION
SHEET
EQUIPMENT TAG1i
GENERAL NOTES APPLY TO ALL DRAWINGS
A. Do not scale the drawings.
B. Verify field conditions prior to commencement of each portion of the work.
C. Dimensions for door and window openings are shown nominal. Allow for
1/4-inch (10) shimming and sealant of exterior frames.
D. Dimensions:
a. All dimensions referencing existing work are to be field verified and are from finished faces of walls & column(s)/surround(s), unless otherwise noted.
b. All dimensions referencing new work are actual and are to face of studs, face of concrete walls, face of CMU walls, face of frames, or centerline of columns, unless noted otherwise.
E. Floor spot elevations are shown thus 00'-0".
F. Architectural finish floor elevation 100'-0" equals actual site reference elevation of finish floor feet.
G. General contractor shall coordinate all mechanical chase sizes with mechanical subcontractor.
H. The owner shall be responsible for providing the contractor with rough-in information necessary to accommodate the installation of owner furnished and installed items.
I. The contractor shall include all owner furnished and installed items in the construction schedule, and shall coordinate with the owner to accommodate these items.
J. General contractor shall coordinate sizes and locations of concrete housekeeping pads with the mechanical and electrical equipment suppliers. Paint all edges of equipment pads safety yellow.
K. General contractor is required to provide secure key safes (Knox Box brand or approved equal) in quantity, size, key type, and location as required by local fire officials.
L. Safety glazing shall be required in the following locations. See IBC Chapter 24 for exceptions.:
a. Doors
b. Windows (including sidelites and borrow lites) within 24" of any door where the glazing is less than 60" above the walking surface
c. Windows, when all of these conditions are met:
• The exposed glazing is larger than 9sf
• The bottom edge of glazing is less than 18" above the floor
• The top edge of the glazing is greater than 36" above the floor
• One or more walking surfaces are within 36" of the glazing plane
d. Glazing in guards and railings, including baluster and infill panels
e. Within 60" of a bathtub, hot tub, spa, whirlpool, or swimming pool if the bottom edge of the glazing is less than 60" above the walking or standing surface
f. Windows adjacent to stairways or walkways where the glazing is less than 60" above the walking surface
g. Fire department access panels (including all panes of a multi-pane insulated glass unit)
E X
IS
T
IN
G
N E
W
D E M
O L
IS
H E D
FLOOR
FLOOR/ROOF SLAB OR
BLDG STRUCTURE
CEILING
(IF PRESENT)
5/8" GYPSUM WALLBOARD
3 5/8" METAL STUDS @ 16" o.c.
5/8" GYPSUM WALLBOARD
4 7/8"
SF1A
SLIP JOINT
NOTE: (TYP. @ ALL STEEL STUD FRAMED FULL-HEIGHT WALLS)
PROVIDE CONTINUOUS DEEP LEG DEFLECTION TRACK AND TOP TRACK AT TOP OF WALL
4"
GWB BOTH SIDES -
GWB EXT 4" ABOVE CLG
5/8" GYPSUM WALLBOARD
3 5/8" METAL STUDS @ 16" o.c.
5/8" GYPSUM WALLBOARD
4 7/8"
SOUND INSULATION
CONT. ACOUSTICAL SEALANT (BOTH
SIDES)
CONT. ACOUSTICAL SEALANT (BOTH
SIDES)
SLIP JOINT
SF2D
GWB BOTH SIDES -
3 1/2" SAFB IN CAVITY
ACOUSTICAL SEALANT
SF2E
GWB ONE SIDE ONLY -
3 1/2" SAB IN CAVITY
ACOUSTIC SEALANT
3 5/8" MT; STUD @ 16" O.C.
GWB 2 SIDES EXTNDNG 4" ABOVE CLG SYS
3 1/2" SAB IN CAVITY AND 24" TO EITHER
SIDE ABOVER CLG
5/8" GYPSUM WALLBOARD
3 5/8" METAL STUDS @ 16" o.c.
5/8" GYPSUM WALLBOARD
3 1/2" SAFB INSULAITON
CONT. ACOUSTICAL SEALANT (BOTH
SIDES)
CONT. ACOUSTICAL SEALANT (BOTH
SIDES)
SLIP JOINT
SF2F
1/2" RESILIENT CHANEL @ 24"
O.C.
SF2K
TYPE-X GWB BOTH SIDES -
3 1/2" SAB IN CAVITY
1 HOUR RATED / UL DESIGN 419
2 1/2" MTL STUD @ 12" O.C.
GWB 1 SIDESF10
2 1/2" METAL STUDS @ 12" o.c.
5/8" GYPSUM WALLBOARD
SLIP JOINT
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
A-0.0
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- A S S E M
B
LY
T Y
P E S
N O
TE
S
A N
D S
Y M
B O
LS
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
ASSEMBLY TYPE PREFIXES ASSEMBLY NOTES
DRAWING SYMBOLS
GENERAL PROJECT NOTES
AB ANCHOR BOLT
ABV ABOVE
ACT ACOUSTICAL CEILING TILE
ADD ADDITIONAL
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE, APPROXIMATELY
ARCH ARCHITECTURAL, ARCHITECT
AUTO AUTOMATIC
BD BOARD
BKHD BULKHEAD
BL BUILDING LINE, BASE LINE
BLDG BUILDING
BOT BOTTOM
BRG BEARING
BTW BETWEEN
CFMF COLD-FORMED METAL FRAMING
CH CHANNEL
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CTR CENTER
ARCHITECTURAL ABBREVIATIONS
PROJECT PHASE GRAPHICS LEGEND
DBL DOUBLE
DEPT DEPARTMENT
DIA DIAMETER
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXIS EXISTING
EXP EXPANSION
EXT EXTERIOR
FCB FIBER-CEMENT BOARD
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FFE FINISHED FLOOR ELEVATION
FG FINISH GRADE
FIN FINISH, FINAL
FLEX FLEXIBLE
FLR FLOOR
FOB FACE OF BRICK
FOC FACE OF CONCRETE
FOE FACE OF EXISTING
FOS FACE OF STUD
FR FIRE RESISTANT
FRP FIBER-REINFORCED PLASTIC
FRT FIRE-RETARDANT TREATED
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GFI GROUND FAULT INTERRUPTER
GWB GYPSUM WALLBOARD
GYP GYPSUM
HC HANDICAP
HDW HARDWARE
HM HOLLOW METAL
HOR HORIZONTAL
HP HIGH PRESSURE
HR HOUR
HSS HIGH STRENGTH STEEL
HT HEIGHT
HYD HYDRANT
IAW IN ACCORDANCE WITH
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
MANF MANUFACTURER
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTD MOUNTED
MTG MOUNTING
MTL METAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR
INSTALLED
OH OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
OVHD OVERHEAD
P-LAM PLASTIC LAMINATE
PEMB PRE-ENGINEERED METAL BUILDING
PL PLATE
PNL PANEL
PR PAIR
PT PRESSURE TREATED
PWD PLYWOOD
R RISER
RAF RAISED ACCESS FLOOR
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCING, REINFORCED
REQD REQUIRED
REV REVISION
RM ROOM
RO ROUGH OPENING
SAB SOUND ATTENUATION BLANKET
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURE, STRUCTURAL
SURF SURFACE
SW SIDEWALK
T TREAD
REVISIONS ▼
TEMP TEMPERATURE, TEMPERED
TG TONGUE & GROOVE
THD THRESHOLD
TO TOP OF
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TRTD TREATED
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VER VERTICAL
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
WC WATER CLOSET
WD WOOD
WF WIDE FLANGE
WH WATER HEATER
WO WITHOUT
WRB WEATHER-RESISTIVE BARRIER
WT WEIGHT
WWF WELDED WIRE FABRIC
XP EXPLOSION PROOF
YD YARD DRAIN
SCALE: 1" = 1'-0" SHEET: A-0.01 INTERIOR WALL ASSEMBLIES
DN
DN
DN
A
A.2
C
B
B.5
A.3
D
I
2 3 4 5 6
6.2 6.5
E
0.5
364 363
360 359
356 355
349 348
345 344
334 327
328 326
325329
330 324 323
320B
368 372
375 379
376 380
392 397
391 396
395390
389 394
393388
399A
399C 399B 306 E4-4
308 309
320 300A
S03
E3-4
E2-4
E1-4
310A
310B
310C
311A
311B
S02/1
MECHANICAL CHASE
MECHANICAL
CHASE
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
AE-1.3
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- E X
IS
TI
N G
C O
N D
IT
IO
N S P
LA
N rd
F
LO
O R
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
KEYED DEMOLITION NOTES
# Note Text
SCALE: 3/32" = 1'-0" SHEET: AE-1.31 03 THIRD FLOOR - EXISTING CONDITIONS
REVISIONS ▼
N
A
A.2
C
B
B.5
A.3
D
I
2 3 4 5 6
6.2 6.5
E
0.5
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
AE-1.4
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- E X
IS
TI
N G
C O
N D
IT
IO
N S P
LA
N th
F
LO
O R
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
KEYED DEMOLITION NOTES
# Note Text
REVISIONS ▼
SCALE: 3/32" = 1'-0" SHEET: AE-1.41 04 FOURTH FLOOR - EXISTING CONDITIONS
R E
F
R E
F
DN
DN
DN
DN
DN
A
A.2
C
B
B.5
A.3
D
I
2 3 4 5 6
6.2 6.5
E
D01 D01
D02 D02
D01
D01 D01
D01
D01
D03
D01
D04
D04
D04
D04
D04
D06
D04
D05
D08D08
D08 D08
D08
D08 D08
D08D08
D08
D08
D08
D08
D08
D08
D08
D07
D01
D04
D10
STAIR 1
S01-3
STAIR 3
S03-3
STAIR 2
S02-3
SHELL SPACE
LAUNCH LAB -
VACANT
MTG
VACANT
ELEV
E3-3
ELEV
E2-3
ELEV
E1-3
F ELEV
E4-3
ELEC
IT CLST
MEN
WOMEN'S
CUSTODIAL
MTG
MTG
ROOFROOF
EXISTING COVERED WALKWAY
D09
D09
D09
D08
D03
D11
D11
D11
D11
D11
D11
D11
D11D13
D14
D14
D15
D16
D16
D06
D17
D10D10
D10
D10
D03
D12
D12
MECHANICAL
CHASE
MECHANICAL
CHASE
A. Coordinate all demolition/phasing efforts with the architect, engineer and owner's representatives. Every effort shall be made to minimize disruption of adjacent operations and to ensure public safety and safe working conditions. Excessive noise or vibration shall be pre-approved and coordinated with the owner's representative.
B. Coordinate with the owner any pre-approved disruption and verification of service within the existing building so as to minimize the disruption of service.
C. Provide temporary dust partition protecting access enclosures where noted and as directed by the owner or architect around all areas of work to prevent the spread of construction debris and dust. Temporary partitions to be constructed prior to start of the demolition work. Isolate any demolition/construction work from the general public and maintain means of egress throughout the work.
D. Maintain a secure, weather-tight enclosure at the exterior of the existing building throughout the demolition/construction portion of the work in that area. Building security shall be coordinated with the owner.
E. Verify all existing conditions, dimensions, and elevations and notify the architect-engineer of any discrepancies.
F. Remove in their entirety all existing walls, doors, millwork, plumbing fixtures, etc. as required to execute the demolition/construction work described by the architect-engineer.
G. Remove all demolition materials from the site unless noted otherwise. The owner shall reserve the right to salvage any materials.
H. Provide protection for all existing building materials and equipment from damage due to any demolition or construction-related incident performed under this contract.
I. Repair or replace any walls, floors, or equipment damaged as a result of demolition or construction to match existing finish and/or condition.
J. The contractor shall coordinate with the architect-engineer any materials to be reused and will be responsible for verifying and maintaining the functional and aesthetic integrity of the materials.
K. Verify and maintain the location of existing power, communication and data cables so as not to inadvertently interrupt the continuity of their service.
L. Patch all floor and ceiling penetrations resulting from removal or rerouting of new or existing piping, ductwork, conduit, etc...as required to maintain fire separations. Finish as required for new or existing adjacent surfaces.
M. Cap all disconnected mechanical piping lines within the wall or floor. Patch and finish as required to match new or existing adjacent surfaces.
N. See MEP drawings and notes for further sequencing and scope of work.
O. Avoid any disturbance of soils within the zone of influence around existing footings and floor slabs as directed by soils engineer.
P. Remove portions of existing concrete slabs as required for new mechanical, electrical and/or plumbing work. Coordinate locations and sizes with mechanical, electrical and/or plumbing installers. Patch concrete slabs to match existing. Install vapor barrier prior to pouring slab.
Q. Contractor to remove all unnecessary or abandoned piping, conduit and wiring that is accessible without additional demolition.
R. Areas showing the removal of walls to be properly shored up, if necessary. The contractor is responsible for determining which areas are to be shored and the structural integrity of such shoring.
S. Notes showing demolished conduit, gas lines, waterlines and air lines assume demolition of entire line referenced.
T. Remove and or reinstall ceilings as required by mechanical, electrical or plumbing ceiling work in areas where no architectural demolition work or limited demolition work is being done. Reinstall ceilings and patch to match existing.
U. Any demolition work necessary on floor above or below (demolition required to install new work) shall be scheduled with the owner. Any finishes disturbed or damaged as a result of demolition or installation shall be patched or replaced to match existing finishes.
V. Contractor to remove all room and cubicle designation signs. Coordinate with owner for possible re-use/storage.
AREA NOT IN SCOPE
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
AD-1.3
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- D E M
O
LI
TI
O
N P
LA
N rd
F
LO
O R
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
SCALE: 3/32" = 1'-0" SHEET: AD-1.31 03 THIRD FLOOR DEMOLITION PLAN
REVISIONS ▼
N
GENERAL DEMOLITION NOTES GRAPHICS LEGEND KEYED CONSTRUCTION NOTES
# Note Text
D01 REMOVE EXISTING BAY OF CUBLICLE(S) AND FURNITURE SYSTEMS.
SALVAGE AND STORE PER OWNERS INSTRUCTIONS.
D02 REMOVE DENOTED PORTION OF EXISTING BAY OF CUBLICLE(S) AND
FURNITURE SYSTEMS. SALVAGE AND STORE PER OWNERS
INSTRUCTIONS.
D03 SAW CUT AND REMOVE PORTION OF WALL IN PREPERATION FOR
INSTALLATION OF NEW STOREFRONT ENTRY SYSTEM. COORDINATE
WITH NEW WORK DRAWINGS FOR DIMENSIONS. PATCH AND REPAIR
SLAB AND ADJOINING WALLS TO CREATE A SEAMLESS TRANSITION
BETWEEN NEW AND EXISTING CONDITIONS IN PREPERATION FOR THE
INSTALLATION OF NEW FINISHES.
D04 REMOVE WALLS IN THIER ENTIRETY, PATCH AND REPAIR ADJOINING
SLAB(S), DECK(S) AND WALL(S), COORDINATING WITH NEW DRAWINGS,
IN PREPERATION FOR THE INSTALLATION OF NEW WALLS, FLOORS,
CEILINGS AND THIER PLANNED FINISHES.
D05 REMOVE DENOTED EXISTING CASEWORK (BASE & WALL CABINETS) AND
PORTION OF COUNTER(S) IN PREPERATION FOR DIVISION OF ROOM INTO
TWO SEPERATE SPACES. COORDINATE WITH NEW WORK.
D06 SAW CUT AND REMOVE PORTION OF WALL IN PREPERATION FOR
INSTALLATION OF NEW FRAME AND DOOR. COORDINATE WITH NEW
WORK DRAWINGS FOR DIMENSIONS. PATCH AND REPAIR SLAB AND
ADJOINING WALLS TO CREATE A SEAMLESS TRANSITION BETWEEN NEW
AND EXISTING CONDITIONS IN PREPERATION FOR THE INSTALLATION OF
NEW FINISHES.
D07 REMOVE EXISTING REFRIGERATOR. SALVAGE AND STORE PER OWNERS
INSTRUCTIONS.
D08 REMOVE FLOOR FINISHES AND CEILINGS, COORDINATING WITH NEW
WORK DRAWINGS FOR FULL EXTENTS OF AREAS WHERE MATERIAL ARE
TO BE REMOVED.
D09 REMOVE FLOOR FINISHES AND CEILINGS, COORDINATING WITH NEW
WORK DRAWINGS FOR FULL EXTENTS OF AREAS WHERE MATERIAL ARE
TO BE REMOVED.
D10 REMOVE EXISTING DESK(S)/FURNITURE SYSTEM. COORDINATE WITH
OWNER FOR STORAGE/RELOCATION, IN NEW WORK.
D11 REMOVE AND SALVAGE DOOR PANEL(S), FRAME AND ALL ACCESSORIES.
COORDINATE WITH OWNER FOR SALVAGE, STORAGE, AND/OR RE-USE.
D12 REMOVE AND SALVAGE DOOR PANEL(S), FRAME AND ALL ACCESSORIES.
INFILL OPENING AND MATCH NEW SURFACES & FINISHES TO EXISTING
ADJOINING SURROUNDING MATERIALS & FINISHES. COORDINATE WITH
OWNER FOR SALVAGE, STORAGE, AND/OR RE-USE.
D13 REMOVE AND RELOCATE EXISTING FIRE EXTINGUISHER CABINET TO NEW
LOCATION. COORDINATE WITH NEW WORK DRAWINGS.
D14 REMOVE EXISTING CASEWORK (BASE AND WALL CABINETS) AND
COUNTER. REPAIR AND PREP REMAINING ADJOINING SURFACES TO
RECIEVE NEW FINISHES. COORDINATE WITH NEW DRAWINGS.
D15 EXISTING WALL OPENING TO BE INFILLED. FINISHED SURFACES TO BE
MATCHED AND ALIGNED TO ADJACENT FINISHED SURFACES AND
PREPARED TO REVIECE NEW FINISHES. COORDINATE WITH NEW WORK
DRAWINGS.
D16 EXISTING WALL TO BE UPGRADED TO A 1 HOUR FIRE RATING. INSPECT,
PATCH AND REPAIR WALL AS REQUIRED TO COMPLETE THE UPGRADE.
PREPARE SURFACES FOR THE INSTALLATION OF NEW FINISHES.
CORRDINATE WITH NEW WORK DRAWINGS.
D17 EXISTING WALL PATCHED, REPAIRED AND REPAINTED
A
A.2
C
B
B.5
A.3
D
I
2 3 4 5 6
6.2 6.5
E
0.5
ELEV
E1-4
ELEV
E2-4
ELEV
E3-4
F ELEV
E4-4
STAIR 3
S03-4
MEN
WOMEN
CUSTODIAL
CORRIDOR
ELEC RM
LOBBY
STAIR 2
S02-4
STAIR 1
S01-4
D10
D10
D10
D06
D18
A. Coordinate all demolition/phasing efforts with the architect, engineer and owner's representatives. Every effort shall be made to minimize disruption of adjacent operations and to ensure public safety and safe working conditions. Excessive noise or vibration shall be pre-approved and coordinated with the owner's representative.
B. Coordinate with the owner any pre-approved disruption and verification of service within the existing building so as to minimize the disruption of service.
C. Provide temporary dust partition protecting access enclosures where noted and as directed by the owner or architect around all areas of work to prevent the spread of construction debris and dust. Temporary partitions to be constructed prior to start of the demolition work. Isolate any demolition/construction work from the general public and maintain means of egress throughout the work.
D. Maintain a secure, weather-tight enclosure at the exterior of the existing building throughout the demolition/construction portion of the work in that area. Building security shall be coordinated with the owner.
E. Verify all existing conditions, dimensions, and elevations and notify the architect-engineer of any discrepancies.
F. Remove in their entirety all existing walls, doors, millwork, plumbing fixtures, etc. as required to execute the demolition/construction work described by the architect-engineer.
G. Remove all demolition materials from the site unless noted otherwise. The owner shall reserve the right to salvage any materials.
H. Provide protection for all existing building materials and equipment from damage due to any demolition or construction-related incident performed under this contract.
I. Repair or replace any walls, floors, or equipment damaged as a result of demolition or construction to match existing finish and/or condition.
J. The contractor shall coordinate with the architect-engineer any materials to be reused and will be responsible for verifying and maintaining the functional and aesthetic integrity of the materials.
K. Verify and maintain the location of existing power, communication and data cables so as not to inadvertently interrupt the continuity of their service.
L. Patch all floor and ceiling penetrations resulting from removal or rerouting of new or existing piping, ductwork, conduit, etc...as required to maintain fire separations. Finish as required for new or existing adjacent surfaces.
M. Cap all disconnected mechanical piping lines within the wall or floor. Patch and finish as required to match new or existing adjacent surfaces.
N. See MEP drawings and notes for further sequencing and scope of work.
O. Avoid any disturbance of soils within the zone of influence around existing footings and floor slabs as directed by soils engineer.
P. Remove portions of existing concrete slabs as required for new mechanical, electrical and/or plumbing work. Coordinate locations and sizes with mechanical, electrical and/or plumbing installers. Patch concrete slabs to match existing. Install vapor barrier prior to pouring slab.
Q. Contractor to remove all unnecessary or abandoned piping, conduit and wiring that is accessible without additional demolition.
R. Areas showing the removal of walls to be properly shored up, if necessary. The contractor is responsible for determining which areas are to be shored and the structural integrity of such shoring.
S. Notes showing demolished conduit, gas lines, waterlines and air lines assume demolition of entire line referenced.
T. Remove and or reinstall ceilings as required by mechanical, electrical or plumbing ceiling work in areas where no architectural demolition work or limited demolition work is being done. Reinstall ceilings and patch to match existing.
U. Any demolition work necessary on floor above or below (demolition required to install new work) shall be scheduled with the owner. Any finishes disturbed or damaged as a result of demolition or installation shall be patched or replaced to match existing finishes.
V. Contractor to remove all room and cubicle designation signs. Coordinate with owner for possible re-use/storage.
AREA NOT IN SCOPE
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
AD-1.4
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- D E M
O
LI
TI
O
N P
LA
N th
F
LO
O R
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
REVISIONS ▼
N SCALE: 3/32" = 1'-0" SHEET: AD-1.41 04 FOURTH FLOOR DEMOLITION PLAN
GENERAL DEMOLITION NOTES GRAPHICS LEGEND KEYED CONSTRUCTION NOTES
# Note Text
D06 SAW CUT AND REMOVE PORTION OF WALL IN PREPERATION FOR
INSTALLATION OF NEW FRAME AND DOOR. COORDINATE WITH NEW
WORK DRAWINGS FOR DIMENSIONS. PATCH AND REPAIR SLAB AND
ADJOINING WALLS TO CREATE A SEAMLESS TRANSITION BETWEEN NEW
AND EXISTING CONDITIONS IN PREPERATION FOR THE INSTALLATION OF
NEW FINISHES.
D10 REMOVE EXISTING DESK(S)/FURNITURE SYSTEM. COORDINATE WITH
OWNER FOR STORAGE/RELOCATION, IN NEW WORK.
D18 REMOVE PORTIONS OF FLOORS AND CEILING AS REQUIRED TO BUILD A
NEW PARTITION WALL. CORODINATE WITH NEW WORK
F
DN
DN
DN
DN
DN
TESTING CENTER
TESTING CNTR
RCPTN
TESTING CENTER
OFFICE
STO
W/C
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MTG
MTG
RCPTN
KITCHEN
OFFICE
MTG
MTG
WAITING
MTG
STORAGE
CLASSROOM
SHELL SPACE
STORAGE
VACANT
LAUNCH LAB -
VACANT
CORR
C2
CORRIDOR
C305
MEN
WOMEN'S
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
STAIR 5
S05-3
F ELEV
E4-3
ELEC
IT CLST
STAIR 3
S03-3
STAIR 1
S01-3
STAIR 2
S02-3
BEVERAGE
STATION
CUBICLE
CUBICLE
COLLABORATION
CUBICLE
CUBICLE
CUBICLE
CUBICLE
LOUNGE
10'-0" 156'-0" 32'-4 1/2" 10'-11 5/8" 3'-7 1/4"
198'-4 1/2"
31'-2" 1'-2 1/2"
6'-0" 6'-0" 3'-0" 6'-0" 3'-0" 6'-0" 6'-0" 6'-0" 3'-0" 6'-0" 3'-0" 6'-0" 6'-0" 9'-0" 6'-0" 3'-0" 6'-0" 6'-0" 6'-0" 3'-0" 6'-0" 3'-0" 6'-0" 6'-0" 6'-0" 3'-0" 6'-0" 3'-0" 6'-0" 6'-0"
106'-0"
10'-0"
96'-0"
12'-8"
6'-9 1/4"
6'-0"
6'-0" 3'-0"
6'-0" 3'-0"
6'-0"
6'-0"
6'-0" 3'-0"
6'-0" 3'-0"
6'-0"
6'-0"
6'-0" 3'-0"
6'-0" 3'-0"
6'-0"
6'-0"
'-4
'-0
'-0
'-4
10'-0"
96'-0"
14'-8 3/4"
106'-0"
6'-0"
6'-0" 3'-0"
6'-0" 3'-0"
6'-0"
6'-0"
6'-0" 3'-0"
6'-0" 3'-0"
6'-0"
6'-0"
6'-0" 3'-0"
6'-0" 3'-0"
6'-0"
6'-0"
6'-0" 12'-0" 24'-7 1/2" 17'-4 1/2" 6'-0" 30'-0" 18'-8" 5'-4" 6'-0" 24'-0" 6'-0"
10'-0" 156'-0" 6"
166'-0"
7'-
/2
1'-
1/ 4"
'-4
7'
-7
/2
'-0
'-0
'-4
5' -4
6'
-0
3' -0
6'
-0
3' -0
6'
-0
6' -8
6'
-0
6' -0
3'
-4
ROOFROOF
EXISTING COVERED WALKWAY
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
A-1.3
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- N E W
W O
R K
P
LA
N rd
F
LO
O R
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
N SCALE: 3/32" = 1'-0" SHEET: A-1.31 03 THIRD FLOOR
F
DN
DN
DN
A
A.2
C
B
B.5
A.3
I
6.2
A-4.1
B
B02
B
B04
B04 B04 B03 B04 B04
320-1
318 316
B
TESTING CENTER
TESTING CNTR
RCPTN
TESTING CENTER
OFFICE
STO
W/C
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
B03
MTG
MTG
RCPTN
KITCHEN
OFFICE
A-4 .1
A
A-4.1
CORRIDOR
C305
C03
C01
C02 C02
C03 C02
C02
C02
11 1/2" 28'-6" 5'-1 5/8" 5'-0" 7 1/4"
C01
C02
C02
C03
C01 C03 C03
C01
8' -8
/8
9'
-1
7/ 8"
7/
8"
'-0
/8
'-9
9'
-0
/8
1' -0
/2
7'
-2
7/
8"
9' -0
/8
'-5
6' -1
0" 4'
-1
7/ 8"
C05
'-5
/8
8'
-2
/8
3' -1
/8
'-0
/8
A-5.1
60'-10" 1'-10" 30'-0" 8'-6 3/4" 11'-0 3/8"
'-8
/8
'-8
/8
5' -0
2'
-1
/4
1' -8
29'-11 3/8" 10'-3" 4'-6 5/8" C04
C04
C04
'-9
/4
A-5 .12
BEVERAGE BAR
C04
SF1A
SF1A
SF1A
SF1A
SF1A
SF1A
SF1A
SF1A
SF1A
SF2E
0.5
0.5
CUBICLE
CUBICLE
'-0
2'
-1 0"
'-8
58'-2" 1'-10" 28'-0" 2'-0" 9'-10 3/4" 4'-10 5/16" 13'-2 13/16" 31'-7 1/4"
SF10 SF10 SF10 SF10 SF10
11'-9" 14'-0" 12'-9 3/4" 11'-0 3/8"
ROOFROOF
EXISTING COVERED WALKWAY
6'-6 1/4"
(TYP)
1'-0 1/4" 9'-11 3/4" 1'-0 1/4" 9'-11 3/4" 1'-0 1/4" 9'-11 3/4" 1'-0 1/4" 9'-11 3/4" 1'-0 1/4" 9'-3 1/2" 1'-10"
SF1A
SF1A
8' -0
/4
(T
YP
8"
'-9
/4
MECHANICAL CHASESTAIR 5
S05-3
CUBICLE
COLLABORATION
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
CUBICLE
STAIR 1
S01-3
IT CLST
ELEC
F ELEV
E4-3
CUSTODIAL
MEN
WOMEN'S
STAIR 3
S03-3
LOBBY
LOBBY
MTG
11'-11 3/8" 10'-3 5/8" 9'-2 3/8" 10'-6" 10'-3 5/8" 12'-2 1/4"
362/1360/1358/1356/1354/1352/1
LOUNGE
CIRCULATION
351A
SF1A
SF1A SF1A SF1A SF1A SF1A
SF1A
C04
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
A-1.3a
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- N E W
W O
R K
P
LA
N rd
F
LO
O R
A
R E A
A
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
N SCALE: 3/16" = 1'-0" SHEET: A-1.3a1 03 THIRD FLOOR - AREA A
REVISIONS ▼
KEYED CONSTRUCTION NOTES
# Note Text
C01 CONSTRUCTION JOINT(S) ABBUTED TO EXISTING WALLS
C02 CONSTRUCTION JOINTS SPACED EVENLY, MAXIMUM SPACING OF 25'-0"
C03 CONSTRUCTION JOINT ALIGNED TO DOOR OPENING.
C04 ALIGN FINISHES
C05 INFILL EXISTING WALL AND PREPARE FOR NEW WALL FINISH AS
INDICATED ON NEW WORK PLANS.
DN
A
A.2
C
B
B.5
A.3
D
I
6.2 6.5
E
B04 B04
372/1
OFFICE
OFFICE
MTG
MTG
RCPTN
318 MTG
MTG
WAITING
MTG
STORAGE
CLASSROOM
SHELL SPACE
STORAGE
VACANT
LAUNCH LAB -
VACANT
CORR
C2
CORRIDOR
C305
C03 C01
F ELEV
E4-3
CUSTODIAL
WOMEN'S
STAIR 3
S03-3
LOBBY
MTG
12'-2 1/4"
LOBBY
51'-3"
14'-9 3/4"
7'-6"
7'-7 1/2"
'-8
/2
'-3
/2
26'-10 9/16"
'-4
/8
'-5
/2
3'-
/8
1'-
1/ 4"
'-6
/8
9'-8 13/16"
3'-1"
12'-10 3/4"
371-2
371-1
STAIR 2
S02-3
CHASE
ELEV
E1-3
ELEV
E2-3
ELEV
E3-3
362/1360/1
LOUNGE
SF1A
SF1A
Copyright. © All rights reserved. Reproduction in whole or in part is prohibited. This drawing is an instrument of service, is the property of the Architect and may not be used in any way without written permission of this firm.
Project No: Drawn by:
A-1.3b
2024003.02 GAM
2025.10.21
PROGRESS DRWGS
NOT FOR CONSTR.
CODE ANALYSIS
W V
U E
V A
N S D
A
LE
C R
O S S
IN
G R
E N
O V
A
TI
O N
C O
D E R
E V
IE
W
- N E W
W O
R K
P
LA
N rd
F
LO
O R
A
R E A
B
M
O R
R
IL
L W
A Y
M O
R G
A N
TO
W
N W
V
N
REVISIONS ▼
SCALE: 3/16" = 1'-0" SHEET: A-1.3b1 03 THIRD FLOOR - AREA B
KEYED CONSTRUCTION NOTES
# Note Text
C01 CONSTRUCTION JOINT(S) ABBUTED TO EXISTING WALLS
C03 CONSTRUCTION JOINT ALIGNED TO DOOR OPENING.
A
A.2
C
B
B.5
A.3
D
I
2 3 4 5 6
6.2 6.5
E
0.5
CIRC
CIR-42
PHONE BOOTH
OFFICE
CONFERENCE
OFFICE
ELEV
E3-4
ELEV
E2-4
ELEV
E1-4
F ELEV
E4-4
LOBBY
STAIR 3
S03-4
400/3
403/2
402/1
CORRIDOR
STAIR 2
S02-4
STAIR 1
S01-4
CIRC.
CIR-41
ELEC RM
MECHA…