EXHIBIT D - Scope- APSC-Bldg.pdf
PDF 171 KB Posted
- Attached to
- Maaske and APSC Remodel RFP
- Solicitation number
- S-580200-00018488
- Issued by
- Multnomah County, Mission CDP, Oregon
About this file
This file is Exhibit D, a Scope of Work document for a building project, likely associated with the APSC (Arts and Performance Sciences Center) or similar academic institution. The document presents architectural floor plans with labeled spaces and identifies key renovation and relocation requirements. The project scope includes the relocation of Smith Hall 121 auditorium to space 408, requiring redesign of the auditorium space to accommodate this change. Additional work encompasses low voltage installation for network cabling throughout the facility, identification and provision of sound proofing in designated locations, and carpet and paint work in certain areas. The scope also identifies spaces requiring extensive demolition and renovation versus those needing only cosmetic updates, and includes provisions for a new art gallery space within the building.
The document does not specify pricing terms, contract duration, award dates, bid submission deadlines, or site visit requirements. No set-asides, incumbent contractor information, or funding sources are identified in this scope document. The file functions as a technical reference guide for bidders to understand the physical layout of the building, the nature of work required across multiple floors, and the specific functional spaces that will result from the renovation project, including offices, practice rooms, classrooms, storage areas, ensemble rehearsal spaces, and specialized facilities such as a MIDI lab and smart classroom.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
eysterg Rectangle eysterg Rectangle eysterg Text Box
ROTC
eysterg Polygon eysterg Text Box Piano Prof eysterg Text Box Midi Lab eysterg Rectangle eysterg Polygon eysterg Polygon eysterg Polygon eysterg Polygon eysterg Polygon eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Polygon eysterg Polygon eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Text Box Office eysterg Text Box Practice Room eysterg Text Box Storage eysterg Text Box Classroom eysterg Text Box Unavailable eysterg Text Box Break/ copy rm.
Polygon eysterg Polygon eysterg Polygon eysterg Text Box Smart Class eysterg Text Box Ensemble Rehearsal eysterg Text Box Upward Bound eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Line eysterg Line eysterg Rectangle eysterg Polygon eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Text Box Office eysterg Text Box Practice Room eysterg Text Box Storage eysterg Text Box Classroom eysterg Text Box Unavailable eysterg Cloud+ eysterg Cloud+ Auditorium space will need re-design to accomodate relocation of Smith Hall 121 to this space.
eysterg Cloud+ eysterg Cloud+ New art gallery space
Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Rectangle eysterg Text Box Office eysterg Text Box Practice Room eysterg Text Box Storage eysterg Text Box Classroom eysterg Text Box Unavailable eysterg Rectangle eysterg Text Box Notes:
Low voltage work for the network cabling.
Relocation of the Smith Hall 121 auditorium to space 408.
Identify sound proofing locations and provide sound proofing.
Identify space that will only need carpet/paint and areas that will require extensive demolition and renovation.
File details come from the government source that posted it. Updated .