This is a GSA Region 5 escalator inspection checklist form based on ASME A17.2-2014 standards for use in the Great Lakes Region's Building Operations and Tenant Services division. The checklist contains two main inspection sections: External (Section 7) and Internal (Section 8), with detailed items to be checked for compliance. The form requires basic escalator information including step width, rated load, installation date, and inspection date, and allows inspectors to mark items as OK (meets requirements), NG (needs comment), or NA (not applicable).

The inspection items cover comprehensive safety and operational elements including fire protection, geometry, handrails, lighting, safety devices, machinery spaces, drive systems, and earthquake inspection requirements for seismic risk zones. The form includes spaces to record inspector information including QEI number, certifying organization, and signature. This document appears to be a standardized inspection template dated August 2018 that supports the elevator maintenance services contract opportunity for four Minnesota locations.

View the file

Other files

File Type Posted
Solicitation Amendment 47PF0025R0003_0002.pdf PDF
Solicitation Amendment 47PF0025R0003_0001.pdf PDF
Exhibit 7 Elevator Inspection.pdf PDF
Exhibit 12 Model SubkPlan.docx DOCX document
Exhibit 14 Burger Asbestos Letter.docx DOCX document
05 IUEC - Wage Rate - Local 9.pdf PDF
Exhibit 13 Hydraulic Elevator Checklist.pdf PDF
Exhibit 11 CCP Murphy.xls XLS spreadsheet
Exhibit 11 CCP Devitt.xls XLS spreadsheet
Exhibit 11 CCP Wellstone.xls XLS spreadsheet
Exhibit 14 Wellstone Asbestos Letter.docx DOCX document
Exhibit 13 Electric Traction Checklist.pdf PDF
Exhibit 14 Devitt Asbestos Letter.docx DOCX document
Exhibit 11 CCP Burger.xls XLS spreadsheet
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Region 5 – Great Lakes Region FMSP – Building Operations and Tenant Services

Escalator Inspection Checklist – ASME A17.2 – 2014

GENERAL NOTES:

(a) See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A17.2 sections.

(b) OK = meets requirements; NG = insert number to identify comment on back of this Checklist; NA = not applicable

Building:

Address:

City, State:

Escalator #:

Escalator Information

Step width:_________________ Rated Load (lbs):____________

Code Data Plate Install Date:_____________ Inspection Date:_____________

Periodic Inspection □ Category 1 Tests □

7 ESCALATOR — EXTERNAL OK NG NA

7.1 General fire protection

7.2 Geometry

7.3 Handrails

7.4 Entrance and egress ends

7.5 Lighting

7.6 Caution signs

7.7 Combplate and comb step impact device

7.8 Deck barricades and anti-slide devices

7.9 Steps and upthrust device

7.10 Operating and safety devices

7.11 Skirt obstruction device

7.13 Egress restriction (rolling shutter) device

7.14 Speed

7.15 Balustrades

7.16 Ceiling intersection guards

7.17 Step/skirt clearances, panels, and performance index

7.18 Outdoor protection

7.19 MCP and maintenance records

7.20 Earthquake inspection and tests (seismic risk zone 2 or greater)

8 ESCALATOR — INTERNAL

8.1 Machinery space access, lighting, receptacle, and condition

8.2 Machinery space stop switches and Inspection control

8.3 Controller and wiring

8.4 Drive machine and brake

8.5 Speed governor

8.6 Broken drive chain and disconnected motor safety device

8.7 Reversal stop switch

8.8 Broken step chain device

8.9 Step upthrust device

8.10 Missing step device

8.11 Step level device

8.12 Steps, step chains, and trusses

8.13 Handrail systems and safety devices

8.14 Code data plate

8.15 Response to smoke detectors

8.16 Step lateral displacement device

8.17 Inspection control

8.18 Earthquake inspection and tests (seismic risk zone 2 or greater)

NOTES:

Inspected by:

QEI Number:

Certifying Organization:

Signature:

GSA Region 5 - 8/2018