Exhibit 13 Electric Traction Checklist.pdf
PDF 232 KB Posted
- Solicitation number
- 47PF0025R0003
About this file
This is an Electric Traction Elevator Inspection Checklist (ASME A17.2-2014) form used by GSA Region 5's Building Operations and Tenant Services division. The checklist is a comprehensive inspection form for both passenger and freight elevators, divided into six main sections: Inside of Car (20 items), Machine Room (42 items), Top of Car (34 items), Outside Hoistway (12 items), Pit (14 items), and Firefighters' Service (9 items).
The form includes spaces to record basic elevator information including building location, elevator number, rated load, rated speed, freight class, installation date, and inspection date. Each inspection item is marked as OK (meets requirements), NG (requires comment), or NA (not applicable). The checklist covers all major elevator components and systems including safety devices, mechanical equipment, electrical systems, maintenance records, and earthquake inspection requirements for seismic zones. The form concludes with fields for the inspector's information, including QEI number, certifying organization, and signature.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment 47PF0025R0003_0002.pdf | ||
| Solicitation Amendment 47PF0025R0003_0001.pdf | ||
| Exhibit 7 Elevator Inspection.pdf | ||
| Exhibit 12 Model SubkPlan.docx | DOCX document | |
| Exhibit 14 Burger Asbestos Letter.docx | DOCX document | |
| 05 IUEC - Wage Rate - Local 9.pdf | ||
| Exhibit 13 Hydraulic Elevator Checklist.pdf | ||
| Exhibit 11 CCP Murphy.xls | XLS spreadsheet | |
| Exhibit 11 CCP Devitt.xls | XLS spreadsheet | |
| Exhibit 11 CCP Wellstone.xls | XLS spreadsheet | |
| Exhibit 14 Wellstone Asbestos Letter.docx | DOCX document | |
| Exhibit 14 Devitt Asbestos Letter.docx | DOCX document | |
| Exhibit 11 CCP Burger.xls | XLS spreadsheet | |
| Exhibit 13 Escalator Checklist.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Region 5 – Great Lakes Region FMSP – Building Operations and Tenant Services
Electric Traction Elevator Inspection Checklist – ASME A17.2 - 2014
GENERAL NOTES:
(a) See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A17.2 sections.
(b) OK = meets requirements; NG = insert number to identify comment on back of this Checklist; NA = not applicable
Building:
Address:
City, State:
Elevator #:
Elevator Information
Passenger □ Freight □ Rated Load (lbs):____________
Freight Class: _______________ Rated Speed (fpm):__________
Code Data Plate Install Date:_____________ Inspection Date:_____________
Periodic □ Category 1 Tests □ Category 5 Tests □
1 INSIDE OF CAR OK NG NA
1.1 Door reopening device
1.2 Stop switches
1.3 Operating control devices
1.4 Sills and car floor
1.5 Car lighting and receptacles
1.6 Car emergency signal
1.7 Car door or gate
1.8 Door closing force
1.9 Power closing of doors or gates
1.10 Power opening of doors or gates
1.11 Car vision panels and glass car doors
1.12 Car enclosure
1.13 Emergency exit
1.14 Ventilation
1.15 Signs and operating device symbols
1.16 Rated load, platform area, and data plate
1.17 Standby power operation
1.18 Restricted opening of car or hoistway doors
1.19 Car ride
1.20 Earthquake inspection and tests (seismic zone 2 or greater)
2 MACHINE ROOM OK NG NA
2.1 Access to machine space
2.2 Headroom
2.3 Lighting and receptacles
2.4 Machine space
2.5 Housekeeping
2.6 Ventilation
2.7 Fire extinguisher
2.8 Pipes, wiring, and ducts
2.9 Guarding of exposed auxiliary equipment
2.10 Numbering of elevators, machines, controllers, and disconnect switches
2.11 Disconnecting means and control
2.12 Controller wiring, fuses, grounding, etc.
2.13 Governor, overspeed switch, and seal
2.14 Code data plate
2.15 Static control
2.16 Overhead beam and fastenings
2.17 Drive machine brake
2.18 Traction drive machines
2.19 Gears, bearings, and flexible couplings
2.20 Winding drum machine and slack cable rope device, stop motion switch and rope fastening
2.21 Belt-or chain-drive machine
2.22 Motor generator
2.23 Absorption of regenerated power
2.24 AC drives from a DC source
2.25 Traction sheaves
2.26 Secondary and deflector sheaves
2.27 Rope fastenings
2.28 Terminal stopping devices
2.29 Car and counterweight safeties
2.38 Roped water hydraulic elevators
2.40 MCP & Maintenance records
2.41 Static control
2.42 Earthquake inspection & tests (seismic risk zone 2 or greater)
3 TOP OF CAR OK NG NA
3.1 Top of car stop switch
3.2 Car top light and outlet
3.3 Top of car operating device
3.4 Top of car clearance, refuge space, & standard railing
3.5 Normal terminal stopping device
3.6 Final and emergency terminal stopping devices
3.7 Car leveling and anticreep devices
3.8 Top emergency exit
3.9 Floor and emergency identification numbering
3.10 Hoistway construction
3.11 Hoistway smoke control
3.12 Pipes, wiring, and ducts
3.13 Windows, projections, recesses, and setbacks
3.14 Hoistway clearances
3.15 Multiple hoistways
3.16 Traveling cables and junction boxes
3.17 Door and gate equipment
3.18 Car frame and stiles
3.19 Guide rails fastenings and equipment
3.20 Governor rope
3.21 Governor releasing carrier
3.22 Wire rope fastening and hitch plate
3.23 Suspension means
3.27 Crosshead data plate and rope data tags
3.28 Counterweight and counterweight buffer
3.29 Counterweight safeties
3.30 Speed Test
3.33 Compensating ropes and chains
3.34 Earthquake inspection & tests (seismic zone 2 or greater)
4 OUTSIDE HOISTWAY OK NG NA
4.1 Car platform guard
4.2 Hoistway doors
4.3 Vision panels
4.4 Hoistway door locking devices
4.5 Access to hoistway
4.6 Power closing of hoistway doors
4.7 Sequence operation
4.8 Hoistway enclosure
4.9 Elevator parking device
4.10 Emergency doors in blind hoistways
4.12 Standby power selection switch
5 PIT OK NG NA
5.1 Pit access, lighting, stop switch, and condition
5.2 Bottom clearance, runby, and minimum refuge space
5.3 Final and emergency terminal stopping devices
5.4 Normal terminal stopping devices
5.5 Traveling cables
5.6 Governor-rope tension device
5.7 Car frame and platform
5.8 Car and counterweight safeties and guiding members
5.9 Buffers and emergency terminal speed limiting devices
5.10 Compensating chains, ropes, and sheaves
5.12 Car buffer
5.13 Guiding members [rails, rollers, slides]
5.16 Earthquake inspection & tests (seismic risk zone 2 or greater)
6 FIREFIGHTERS’ SERVICE (FEO) OK NG NA
6.1 A17.1b–1973 through A17.1b–1980
6.2 A17.1–1981 through A17.1b–1983
6.3 A17.1–1984 through A17.1a–1988 and A17.3
6.4 A17.1b–1989 through A17.1d–2000
6.5 A17.1-2000 & B44-00
6.6 A17.1-2004 & B44-04
6.7 A17.1-2007 & B44-07
6.8 A17.1-2010 & B44-10
6.9 A17.1-2013 & B44-13
NOTES:
Inspected by:
QEI Number:
Certifying Organization:
Signature:
GSA Region 5 - 8/2018
File details come from the government source that posted it. Updated .