Ex 2 2022 02 28 WPCH - Courtroom 521 - DID FINAL.pdf
PDF 6 MB Posted
- Attached to
- 5th Floor East Courtroom Repairs & Alterations - Charles L. Brieant Jr. Court House in White Plains, NY
- Solicitation number
- 47PC0222R0015
About this file
This document outlines a federal solicitation for design-build services to renovate a courtroom at a federal courthouse. The General Services Administration intends to issue a Request for Proposal for design-build services to renovate the 5th floor District Courtroom Suite 521 at the Charles L. Brieant Jr. Courthouse in White Plains, New York. The design-build contractor will be responsible for developing construction documents, specifications and plans, performing selective demolition work, and renovating the space to match recently completed renovations on the 6th floor courtrooms. Renovations are intended to modernize the courtroom infrastructure and finishes for IT, AV, and security equipment. The contract is a firm-fixed-price contract with a period of performance of 448 calendar days from notice to award. The project magnitude is estimated between $1-5 million. The solicitation will be a 100% total small business set-aside, using a best value tradeoff source selection process evaluating experience, past performance, staffing plan, and price.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S3-56A
S4-57
S4-50
S5-68
S4-49
S4-67A
S4-59
D1-49
(INCLUDES EXIT SIGNS)
ADDITIONAL DEMO PLAN KEY NOTE:
Trench floor as required to accommodate new power/IT/AV wiring as noted elsewhere in these documents, the scope of work and scope of work exhibits.
(alternate 1)
02/24/22 UPDATED BID DOCUMENTS
VirginiaKSimpson Textbox Solicitation no. 47PC0222R0015
*For hardware sets, see Exhibit 9, "6th floor shop drawings and submittals" ** Existing card reader to be removed by owner for re-installation or replacmeent. Contractor to protect existing wiring for final connection to card reader. Re-connection of card reader shall be by owner.
02/24/22 UPDATED BID DOCUMENTS
VirginiaKSimpson
02/24/22 UPDATED BID DOCUMENTS
5. PROTECT ALL EXISTING FIRE ALARM DEVICES AND TEST
AT CONTRACT COMPLETION TO ASSURE THE DEVICES
WERE NOT DAMAGED BY CONSTRUCTION.
6. PROTECT EXISTING SPRINKLER HEADS DURING
CONSTRUCTION.
VirginiaKSimpson
VirginiaKSimpson
RADIATOR COVERS SHALL BE WOOD
TO MATCH ADJACENT MILLWORK.
ATTORNEY ATTORNEY
02/24/22 UPDATED BID DOCUMENTS
VirginiaKSimpson
ATTORNEY
ATTORNEY
VirginiaKSimpson
(OWNER FURNISHED)
VirginiaKSimpson
(FUTURE)
(FUTURE)
(FUTURE)
(FUTURE)
**See POR for specifications for tables and lectern to be provided by DB contractor.
02/24/22 UPDATED BID DOCUMENTS
VirginiaKSimpson
ALL UNUSED WIRING SHALL BE REMOVED. IF IT IS DETERMINED THAT AN UNUSED RACEWAY SHALL BE LEFT IN PLACE FOR FUTURE USE, ALL EXISTING CABLING SHALL BE REMOVED AND THE RACEWAY SHALL BE LEFT
WITH A PULL STRING.
IN AREA "D1". IDENTIFY CIRCUITS MADE SPARE DURING DEMOLITION PHASE AND RE-USE CIRCUITS TO PROVIDE
POWER TO DEVICESAS SHOWN ON NEW POWER PLAN.
AREA "D2" SHALL REMAIN AS IS UNLESS OTHERWISE NOTED.
AREA "D1" - DEMOLITION ZONE.
DEMOLISH OR RE-USE CIRCUITS
AS NECESSARY TO ACHIEVE
FINAL DESIGN
AREA "D2" - MAINTAIN ALL POWER
AND IT IN THIS AREA.
* Card reader to be removed by USMS for re-installation or replacmeent. Contractor to protect existing wiring for final connection to card reader. Re-connection of card reader shall be by owner.
02/24/22 UPDATED BID DOCUMENTS
VirginiaKSimpson
TOTAL NUMBER OF JURY MONITORS IS 10. SEE DWG.
A-501 FOR LOCATIONS OF MONITORS.
TOTAL NUMBER OF JURY
MONITORS IS 10. SEE DWG.
A-501 FOR LOCATIONS OF
MONITORS.
Provide power and data outlets to accommodate A/V rack.
02/24/22 UPDATED BID DOCUMENTS
VirginiaKSimpson