ESBD_433095_1751482950313_SOL_EXH_F.10_405-25R0014809_Hollow Metal Doors.pdf

PDF 388 KB Posted

Attached to
Sierra Blanca New office space remodel
Solicitation number
405-25R0014809
Issued by
Hidalgo County, Texas

About this file

This document is a technical specification section for Hollow Metal Doors issued by the Texas Department of Public Safety (TXDPS) Facilities Bureau on June 13, 2016. The specification provides detailed requirements for fire-rated and non-rated rolled steel flush doors, frames, and associated glazing for a construction or renovation project. It outlines acceptable manufacturers including Amweld Building Products, Benchmark, Ceco Door Products, Curries Company, and Steelcraft, with provisions for submitting equal alternatives for approval.

The specification covers technical details for exterior and interior doors, including gauge specifications, core types, fabrication requirements, and finish characteristics. Exterior doors are specified as 16-gauge galvanized with rain caps, while interior doors are 18-gauge flush panel. Door cores vary between mineral fiberboard for fire-rated doors and various materials for non-rated doors. The finish will be a manufacturer's standard baked-on primer in "Dark Bronze" color, with color samples required for approval. Installation requirements include precise alignment, anchoring, and compliance with specific industry standards such as SDI-105 and DHI guidelines.

View the file

Other files

File Type Posted
ESBD_433095_1751482954684_SOL_EXH_F.4_405-25R0014809_Direct Deposit Authorization.pdf PDF
ESBD_433095_1751482945934_SOL_EXH_F.13_405-25R0014809_Non Structural Metal Framing.pdf PDF
ESBD_433095_1751482957635_SOL_EXH_F.6_405-25R0014809_Statement of Work.pdf PDF
ESBD_433095_1751482948877_SOL_EXH_F.21_405-25R0014809_Summary and Scope of Work.pdf PDF
ESBD_433095_1751482968097_SOL_EXH_F.19_405-25R0014809_Exterior Painting.pdf PDF
ESBD_433095_1751482962313_SOL_EXH_F.17_405-25R0014809_Resilient Athletic resurfacing.pdf PDF
ESBD_433095_1751482973840_SOL_EXH_F.7_405-25R0014809_Wage Determination.pdf PDF
ESBD_433095_1751482956132_SOL_EXH_F.11_405-25R0014809_Flush Wood Doors.pdf PDF
ESBD_433095_1751482947379_SOL_EXH_F.16_405-25R0014809_Resilient luxury vinyl tile flooring.pdf PDF
ESBD_433095_1751482966644_SOL_EXH_F.15_405-25R0014809_Resilience Base and Accessories.pdf PDF
ESBD_433095_1751482951761_SOL_EXH_F.8_405-25R0014809_Cleaning and Waste management.pdf PDF
ESBD_433095_1751482959126_SOL_PST_IFB INVITATION TO BID.pdf PDF
ESBD_433095_1751482970978_SOL_EXH_F.9_405-25R0014809_Selective Demolition.pdf PDF
ESBD_433095_1751482942923_SOL_EXH_F.2_405-25R0014809_Information and Certifications Form.pdf PDF
ESBD_433095_1751482944469_SOL_EXH_F.14_405-25R0014809_Gypsum Board.pdf PDF
ESBD_433095_1751482960572_SOL_EXH_F.12_405-25R0014809_Door Hardware.pdf PDF
ESBD_433095_1751482965204_SOL_EXH_F.5_405-25R0014809_Request for Taxpayer Identification Number and Certification.pdf PDF
ESBD_433095_1751482972423_SOL_EXH_F.20_405-25R0014809_Aluminum Mini Blind System.pdf PDF
ESBD_433095_1751482963730_SOL_EXH_F.18_405-25R0014809_Interior Painting.pdf PDF
ESBD_433095_1751482969533_SOL_EXH_F.1_405-25R0014809_DPS Standard Terms and Conditions.pdf PDF
ESBD_433095_1751482953281_SOL_EXH_F.3_405-25R0014809_Application for Texas Identification Number.pdf PDF
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JUNE 13, 2016 TXDPS Facilities Bureau

Spec Rev. 06-2016

1 08 11 13 Page

SECTION 08 11 13 – HOLLOW METAL DOORS

PART 1 – GENERAL

1.1 RELATED DOCUMENTS

A. Provisions established in the General Requirements of the Scope of Work.

1.2 SECTION INCLUDES

A. Fire rated and non-rated rolled steel flush doors, frames and associated glazing.

1.3 QUALITY ASSURANCE

A. Conform to requirements of SDI-100.

B. Manufacturer: Company specializing in manufacturing the Products specified in this section with minimum ten years of experience.

C. Installed frame and door assembly to conform to UL 10C for fire rated class indicated or scheduled.

1.4 SUBMITTALS

A. Submit shop drawings, and manufacturer's installation instructions.

B. Indicate frame configuration, anchor types and spacing, location of cutouts for hardware, reinforcement, and finish.

C. Indicate door elevations, internal reinforcement, closure method, and cut outs for glazing.

D. Manufacturer's Installation Instructions: Indicate special installation instructions.

E. Submit manufacturer’s product literature.

1.5 DELIVERY, STORAGE AND PROTECTION

A. Protect products under provisions of specification section 01 65 00 – PRODUCT DELIVERY

REQUIREMENTS.

B. Accept doors on site in manufacturer's packaging. Inspect for damage.

C. Break seal on-site to permit ventilation.

1.6 FIELD MEASUREMENTS

A. Verify that field measurements are as indicated on shop drawings.

1.7 COORDINATION

A. Coordinate the work with door opening construction, door frame and door hardware installation.

2 08 11 13 Page

PART 2 – PRODUCTS

2.1 ACCEPTABLE MANUFACTURERS - DOORS AND WELDED UNIT FRAMES

A. Amweld Building Products, LLC.

B. Benchmark; a division of Therma-Tru Corporation.

C. Ceco Door Products; an Assa Abloy Group company.

D. Curries Company; an Assa Abloy Group company.

E. Steelcraft; an Ingersoll-Rand company.

F. Submit equal for approval.

2.2 DOORS AND FRAMES

A. Exterior Doors: SDI-100 Grade III – Heavy Duty, Model 2 - Seamless, flush panel insulated, 16 gage, galvanized with rain cap

B. Interior Doors: SDI-100 Grade II – Heavy Duty Model 2 - Seamless, 18 gage, flush panel doors.

C. Door Frames - Exterior: 14 gage, welded, galvanized

D. Door Frames - Interior (fire rated): 16 gage welded.

2.3 DOOR CORE

A. Core Types

1. Fire Rated Doors: Mineral fiberboard.

2. Non-Rated Doors: Manufacturer's standard kraft-paper honeycomb, polystyrene, polyurethane, mineral-board, or vertical steel-stiffener core that produces doors complying with ANSI A250.8.

B. Provide fire-rated cores as scheduled and as required meeting all applicable codes, whether or not called for on Drawings.

2.4 ACCESSORIES

A. Rubber Silencers: Resilient rubber.

B. Glazing Stops: Rolled steel channel shape, mitered corners; prepared for countersink style tamperproof screws.

C. Anchors: Three per jamb, typically, of type to suit supportive construction.

2.5 FABRICATION

A. Fabricate frames as welded unit. Grind welds smooth prior to delivery.

B. Fabricate frames and doors with hardware reinforcement plates (for locks, closers, and other items

3 08 11 13 Page attached to doors and frames) welded in place. Provide mortar guard boxes.

C. Reinforce frames wider than 48 inches with roll formed steel channels fitted tightly into frame head, flush with top.

D. Prepare frame for silencers. Provide three single rubber silencers for single doors on strike side, and two single silencers on frame head at double doors without mullions.

E. Attach fire rated label to each fire-rated frame and door unit.

F. Close top edge of exterior door flush with inverted steel channel closure. Seal joints watertight.

2.6 FINISH

A. Manufacturer's standard baked-on primer.

B. Color “Dark Bronze”. Contractor to submit color samples for approval prior to order of unit.

PART 3 – EXECUTION

3.1 EXAMINATION

A. Verify that opening sizes and tolerances are acceptable.

B. Verify surfaces and conditions are ready to receive work of this section. Notify Architect of any existing conditions which will adversely affect execution. Beginning of execution will constitute acceptance of existing conditions.

3.2 INSTALLATION

A. Install frames in accordance with SDI-105 and reference U.L. publication.

B. Install doors in accordance with DHI and reference U.L. publication.

C. Coordinate with adjacent construction for anchor placement.

D. Coordinate and provide for installation of glass and glazing as indicated on Drawings and required by code.

E. Install roll formed steel reinforcement channels between two abutting frames. Anchor to structure and floor.

F. Set frames plumb, level, and true alignment, securely fastened to the floor and adjoining walls.

G. Install doors accurately in frames, maintaining specified clearances.

3.3 TOLERANCES

A. Maximum Diagonal Distortion: 1/8 inch measured with straight edge, corner to corner.

3.4 ADJUSTING AND CLEANING

4 08 11 13 Page

A. Adjust hardware and door movement for smooth, quiet and balanced door movement.

END OF SECTION

5 08 11 13 Page

File details come from the government source that posted it. Updated .