ESBD_384442_1735660132451_G.9 Scope of Work.pdf

PDF 875 KB Posted

Attached to
Stephenville Roof Replacement
Solicitation number
TMD25-CFMO-0038145
Issued by
Ellis County, Texline Town, Texas

About this file

This is a Statement of Work (SOW) document from the Texas Military Department's Construction and Facilities Management Office for the Stephenville Readiness Center Roof Replacement project. The project involves replacing the roof of a 19,225-square-foot facility located at 899 East Road in Stephenville, TX that was damaged by a hail and windstorm on June 17, 2023. The scope includes fully replacing roof damage, flashing, window and door openings/frames, and any unforeseen storm damage. Additional options include masonry control joint caulk replacement, gutter and downspout work, new fixed roof ladders, and wood blocking upgrades. The project must be completed within 120 days and comply with ADA Title II accessibility guidelines with TDLR approval.

The estimated repair cost is $300,000 including a 10% contingency. Minimum vendor qualifications include 5 years of professional experience and specific experience with commercial roof replacements. The facility, built in 1958, currently houses the 236th Engineer Company and features CMU construction with masonry bearing walls, floating slabs, and pier-supported grade beams. The contractor must provide material samples upon request and submit a construction schedule of values before mobilization. The property is state-owned on a 13-acre tract in Erath County.

View the file

Other files

File Type Posted
ESBD_384442_1735659885381_G.2 Application for Texas ID.pdf PDF
ESBD_384442_1735660768480_G.12 Specifications_Part2.pdf PDF
ESBD_384442_1735660741001_G.12 Specifications_Part1.pdf PDF
ESBD_384442_1735660608101_G.11 Plans.pdf PDF
ESBD_384442_1735659854107_G.1 Direct Deposit.pdf PDF
ESBD_384442_1735660804775_IFB Stephenville Roof.pdf PDF
ESBD_384442_1735660132451_G.9 Scope of Work.pdf PDF
ESBD_384442_1735660062302_G.6 - HUB Subcontracting Plan.pdf PDF
ESBD_384442_1735660111789_G.8 TMD Solid Waste Reporting form.pdf PDF
ESBD_384442_1735659953254_G.3 TMD Terms and Conditions.pdf PDF
ESBD_384442_1735660088047_G.7 - UGC's and Supps.pdf PDF
ESBD_384442_1735660582764_G.10 Wage Rates1.pdf PDF
ESBD_384442_1735660020728_G.5 Proposal Cost Breakdown.pdf PDF
ESBD_384442_1735659977712_G.4 Pricing Schedule.pdf PDF
ESBD_384442_1735660582764_G.10 Wage Rates1.pdf PDF
ESBD_384442_1735660111789_G.8 TMD Solid Waste Reporting form.pdf PDF
ESBD_384442_1735660768480_G.12 Specifications_Part2.pdf PDF
ESBD_384442_1735659885381_G.2 Application for Texas ID.pdf PDF
ESBD_384442_1735660741001_G.12 Specifications_Part1.pdf PDF
ESBD_384442_1735660088047_G.7 - UGC's and Supps.pdf PDF
ESBD_384442_1735659854107_G.1 Direct Deposit.pdf PDF
ESBD_384442_1735659953254_G.3 TMD Terms and Conditions.pdf PDF
ESBD_384442_1735660608101_G.11 Plans.pdf PDF
ESBD_384442_1735659977712_G.4 Pricing Schedule.pdf PDF
ESBD_384442_1735660804775_IFB Stephenville Roof.pdf PDF
ESBD_384442_1735660020728_G.5 Proposal Cost Breakdown.pdf PDF
ESBD_384442_1735660062302_G.6 - HUB Subcontracting Plan.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment G.9 - Scope of Work Page 1 of 4

STATE OF TEXAS

TEXAS MILITARY DEPARTMENT

CONSTRUCTION AND FACILITIES MANAGEMENT OFFICE

STATEMENT OF WORK

PROJECT INFORMATION

0.0 PROJECT DATA

0.1.1 Project Title: Stephenville-00001-Readiness Center Roof Replacement

0.1.2 Project Address: 899 East Road, Stephenville, TX 76401

0.1.3 Project Number: 48240090

1.0 SITE DESCRIPTION

1.1 PROPERTY DESCRIPTION

The Stephenville Readiness Center is situated on a 13-acre tract of land located in Erath County, Stephenville, TX. The property is state property, and facilities are owned by the State of Texas, Texas Military Department.

1.2 FACILITY DESCRIPTION

The building, spanning 19,225 square feet, was commissioned on 31-March-1958.

Constructed with concrete masonry units (CMU), it features masonry bearing walls, floating slabs on grade, and pier-supported grade beams. The structure includes offices, break areas, restrooms, storage spaces, and a vehicle maintenance bay, all beneath a built-up roof (BUR) that is still under warranty. This building is not designated as a historic structure and presently serves as the home for the 236th Engineer Company.

2.0 PROJECT DESCRIPTION

2.1 The facility was directly affected by a significant hail and windstorm on 17-June-

2023, around 1200 hours. The storm brought intense winds along with substantial rain and hail, resulting in damage to the Stephenville Readiness Center's roof. A considerable repair and restoration effort is required to restore it to a safe and functional state. The following repairs are essential to prevent further damage to the Readiness Center's roof:

New construction and any improvements shall comply with the latest Americans with Disabilities Act ("ADA") Title II accessibility guidelines and will require review and approval from the Texas Department of Licensing & Regulation ("TDLR")

NGTX-F 19-Aug-24 Page 1 of 3 Stephenville Readiness Center Roof Replacement

Attachment G.9 - Scope of Work Page 2 of 4 nd/or repair all roof damage and/or repair any flashing damage nd/or repair any window and door openings and frames and/or repair any unforeseen damages as a direct result of the

Project shall be complete within 120 days.

all roof damage any flashing damage any window and door openings and frames

Fully replace Fully replace Fully replace damage Fully replace any unforeseen damages as a direct result of the hail/windstorm Option #1 Masonry – Replace caulk at masonry control joints and e x t e r i o r openings

Option #2 Metal – Replace gutters downspouts and associated components Option #3 Metal – Re-work downspout at northeast corner of building

Option #4 Metal – New Fixed roof ladders Option #5 Carpentry – Upgrade wood blocking components to kiln-dried pressuretreated lumber Seal Coat masonry

3.0 COST

The Contractors shall provide samples upon request.

The contractor shall provide an accurate construction schedule of values before Mobilization.

All work associated with this project shall be completed within 120 days

3.1 Estimated repair cost is approximately $300,000.00 including a 10% contingency.

4.0 MINIMUM VENDOR QUALIFICATIONS

5 years minimum of professional experience.

Professional experience with commercial roof replacements.

Location Map

TXARNG Stephenville Readiness Center

Attachment G.9 - Scope of Work Page 3 of 4

NGTX-F 19-Aug-24 Page 2 of 3

Attachment G.9 - Scope of Work Page 4 of 4

Aerial View

TXARNG Stephenville Readiness Center

~ END OF SOW ~