ESBD_383359_1732633727962_Exhibit P 60% Construction Documents.pdf

PDF 8 MB Posted

Attached to
Emergency Construction Manager-at-Risk (CMR) for Structural Repairs to the Magoffin Home Visitor Center State Historic Site in El Paso County, Texas
Solicitation number
808-25-250510
Issued by
El Paso County, El Paso City, Texas

About this file

This is a 60% Construction Document set for structural and architectural repairs at the Visitor Center of the Magoffin Home State Historic Site in El Paso, Texas, prepared by JQ Infrastructure LLC for the Texas Historical Commission. The project involves structural and architectural repairs to the interior and exterior envelope of the building located at 1117 Magoffin Avenue, including repair of cracked masonry walls, reconstruction of stone walls, installation of helical reinforcement bars, sealant replacement, and restoration of various architectural elements. The documents are dated November 19, 2024 and are marked as interim review documents not intended for bidding, permitting or construction purposes.

The drawing set includes detailed plans, elevations, sections and specifications covering demolition, structural repairs, and architectural restoration work. Key elements include foundation repairs, wall reinforcement, floor framing modifications, and interior finish restorations. The project requires special inspections for concrete and masonry construction per IBC 2021 requirements. The documents specify material requirements including concrete strength of 3000 psi for foundations, masonry reinforcement details, and requirements for salvaging and reinstalling various architectural elements like toilet partitions, vanities, tile work and other finishes.

View the file

Other files

File Type Posted
ESBD_383359_1732633502705_Exhibit G Prevailing Wages Rates.pdf PDF
ESBD_383359_1732634922373_Exhibit D Contractor's Qualification Stmt.pdf PDF
ESBD_383359_1732633266376_Exhibit B Conflict of Interest.pdf PDF
ESBD_383359_1732633522411_Exhibit H Performance Bond.pdf PDF
ESBD_383359_1732633429875_Exhibit E Sample Contract.pdf PDF
ESBD_383359_1732633650122_Exhibit M RFP Checklist.pdf PDF
ESBD_383359_1732633475659_Exhibit F Insurance Requirements for CMRs.pdf PDF
ESBD_383359_1732633632874_Exhibit L Consent of Surety.pdf PDF
ESBD_383359_1732633727962_Exhibit P 60% Construction Documents.pdf PDF
ESBD_383359_1732633679426_Exhibit N UGC-Supplementary.pdf PDF
ESBD_383359_1732634894027_Exhibit C Proposal form.pdf PDF
ESBD_383359_1732633567379_Exhibit J Contractors Progress Payment Affidavit.pdf PDF
ESBD_383359_1732633234658_Exhibit A Execution of Offer.pdf PDF
ESBD_383359_1732633164973_RFP 808-25-250510 .pdf PDF
ESBD_383359_1732633755870_Exhibit Q HUB Subcontracting Plan.pdf PDF
ESBD_383359_1732633703437_Exhibit O Special Conditions.pdf PDF
ESBD_383359_1732633783446_Exhibit R THC General Terms Conditions 11-14-24.pdf PDF
ESBD_383359_1732633543981_Exhibit I Payment Bond.pdf PDF
ESBD_383359_1732633597738_Exhibit K Contractors Final Payment Affidavit.pdf PDF
ESBD_383359_1732633755870_Exhibit Q HUB Subcontracting Plan.pdf PDF
ESBD_383359_1732634894027_Exhibit C Proposal form.pdf PDF
ESBD_383359_1732633475659_Exhibit F Insurance Requirements for CMRs.pdf PDF
ESBD_383359_1732633650122_Exhibit M RFP Checklist.pdf PDF
ESBD_383359_1732633266376_Exhibit B Conflict of Interest.pdf PDF
ESBD_383359_1732633632874_Exhibit L Consent of Surety.pdf PDF
ESBD_383359_1732633429875_Exhibit E Sample Contract.pdf PDF
ESBD_383359_1732633567379_Exhibit J Contractors Progress Payment Affidavit.pdf PDF
ESBD_383359_1732633679426_Exhibit N UGC-Supplementary.pdf PDF
ESBD_383359_1732633522411_Exhibit H Performance Bond.pdf PDF
ESBD_383359_1732633597738_Exhibit K Contractors Final Payment Affidavit.pdf PDF
ESBD_383359_1732633703437_Exhibit O Special Conditions.pdf PDF
ESBD_383359_1732633164973_RFP 808-25-250510 .pdf PDF
ESBD_383359_1732633502705_Exhibit G Prevailing Wages Rates.pdf PDF
ESBD_383359_1732633543981_Exhibit I Payment Bond.pdf PDF
ESBD_383359_1732634922373_Exhibit D Contractor's Qualification Stmt.pdf PDF
ESBD_383359_1732633783446_Exhibit R THC General Terms Conditions 11-14-24.pdf PDF
ESBD_383359_1732633234658_Exhibit A Execution of Offer.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET INDEX

GENERAL:

C100 COVER SHEET

SP100 SITE PLAN

STRUCTURAL:

SD100 STRUCTURAL DEMOLITION PLAN

S100 STRUCTURAL NOTES

S101 SPECIAL INSPECTIONS, ABBREVIATIONS & SYMBOLS LEGEND

S200 BASEMENT AND CRAWL SPACE FOUNDATION PLAN

S201 FIRST FLOOR FRAMING PLAN

S202 SECOND FLOOR AND ATTIC FRAMING PLAN

S300 BUILDING ELEVATIONS

S400 STRUCTURAL DETAILS

S500 PHOTOGRAPHS

ARCHITECTURAL:

AD101 FIRST FLOOR DEMOLITION PLAN

A101 FIRST FLOOR PLAN

A102 SECOND FLOOR PLAN

A151 FIRST FLOOR REFLECTED CEILING PLAN

A152 SECOND FLOOR REFLECTED CEILING PLAN

A401 INTERIOR ELEVATIONS

A411 ENLARGED BATHROOM PLANS AND ELEVATIONS

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

COVER SHEET

3240186

C100

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

TEXAS HISTORICAL COMMISSSION - MAGOFFIN HOME STATE HISTORIC SITE

VISITOR CENTER - STRUCTURAL & ARCHITECTURAL REPAIRS

OWNER

Texas Historical Commission 1700 North Congress Street Austin, TX 78701

1117 MAGOFFIN AVENUE, EL PASO, TEXAS 79901

STRUCTURAL ENGINEER

JQ Infrastructure, LLC 100 Glass Street, Suite 201 Dallas,TX 75207

(p) 972.392.7340

ARCHITECT

Treanor 2554 Elm Street, Suite 200 Dallas, TX 75226 214.310.1018

OWNER

AREA MAP

PROJECT LOCATION PROJECT LOCATION

AERIAL VIEW

GENERAL INFORMATION

APPLICABLE CODES:

1. INTERNATIONAL EXISTING BUILDING CODE (IEBC 2021)

SCOPE OF WORK

STRUCTURAL AND ARCHITECTURAL REPAIRS TO INTERIOR AND EXTERIOR ENVELOPE.

R e v is io n s

R e v

D e s c ri p ti o n

D a te

ALLOWABLE LIMIT OF

CONTRACTOR LAY

DOWN AREA

TEMPORARY FENCING

ONLY REQUIRED AROUND

AREA REQUIRED BY

CONTRACTOR

2.3

1.3

.35

3.0

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

SITE PLAN

3240186

SP100

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

SCALE: 1" = 10'-0"

1 SITE PLAN

NOTE:

CAP ANY IRRIGATION PIPING CUT

OR DAMGED BY THIS WORK

plan north true north

R e v is io n s

R e v

D e s c ri p ti o n

D

TAPERED BLOCKING TO

PROVIDE FULL BEARING

2-2x6 TOP PLATE - TYP.

2x6 @ 16" O.C. SHORING -

TYP.

2-2x6 SILL PLATE - TYP.

2x12 SILL PLATE

NOTE: CONNECT

SHORING TO EXISTING

FRAMING TO PREVENT

DISPLACEMENT

PROVIDE BLOCKING

BETWEEN STUDS AT

MIDHEIGHT

FIRST FLOOR

SECOND FLOOR

T O

B E

R E

M O

V E

D A

N D

R E

P L A

C E

D

L

IM

IT

S

O F

E X

IS

T

IN

G

B R

IC

K

M A

N S

O N

R Y

1/2" MIN. PLYWOOD W/

WATER RESISTANT

MEMBRANE

SD100

TYP.

EXIST. SHORING

TO BE RELOCATED

TO ALIGN

EXIST. SHORING

L

IM

IT

S

O F

W A

L L D

E M

O L

IT

IO

N

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

STRUCTURAL

DEMOLITION PLAN

3240186

SD100

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

SCALE: 1/2" = 1'-0"

2 TYPICAL SHORING SECTION

SCALE: 1/4" = 1'-0"

1 FIRST FLOOR DEMOLITION PLAN

plan north true north

R e v is io n s

R e v

D e s c ri p ti o n

D

COORDINATION

A. The contractor shall compare the architectural, structural, mechanical, electrical, plumbing, and other series drawings and report any discrepancies between each set of drawings and within each set of drawings prior to fabrication and installation of any structural members.

B. All sleeves, inserts and openings, including frames and/or sleeves shall be provided for passage, provision and/or incorporation of the work of the contract, including but not limited to mechanical, electrical and plumbing work.

This work shall include the coordination of sizes, alignment, dimensions, position, locations, elevations and grades as required to serve the intended purpose. Openings not indicated on the structural drawings, but required as noted above, shall be submitted to the engineer for review.

D. Compatibility of the structure and provisions for building equipment supported on or from structural components shall be verified as to size, dimensions, clearances, accessibility, weights and reaction with the equipment for which the structure has been designed prior to submission of shop drawings and data for each piece of equipment and for structural components. Differences shall be noted on the submittals.

E. Shop drawings shall be prepared for all structural items and submitted for review by the engineer. All items deviating from the structural drawings or from previously submitted shop drawings shall be clouded.

F. The details designated as "typical details" apply generally to the structural drawings in all areas where conditions are similar to those described in the details.

G. All dimensions and conditions of existing construction shall be verified at the job site prior to the preparation of shop drawings. Differences between existing construction and that shown on the structural drawings shall be referred to the architect. Differences shall also be clouded on the shop drawings.

H. All structural elements of the project have been designed by the engineer to resist the required code vertical and lateral forces that could occur in the final completed structure only. It is the responsibility of the contractor to provide all required bracing during construction to maintain the stability and safety of all structural elements during the construction process until the lateral-load resisting or stability-providing system is completely installed and the structure is completely tied together. Temporary supports shall not result in the overstress or damage of the elements to be braced nor any elements used as brace supports.

I. The contract structural drawings and specifications represent the finished structure, and except where specifically shown, do not indicate the means or methods of construction. The contractor and their sub-contractors shall supervise and direct the work and shall be solely responsible for all construction means, methods, procedures, techniques, sequences and safety measures including, but not limited to, adherences to all osha guidelines. The engineer shall not have control of, and shall not be responsible for, construction means, methods, techniques, sequences or procedures, for safety precautions and programs in connection with the work, for the acts or omissions of the contractor, subcontractors, or any other person performing any of the work, or for the failure of any of these persons to carry out the work in accordance with the structural contract documents.

J. Where conflict exists among the various parts of the contract documents,drawings, general notes, and specifications, the strictest requirements, as indicated by the engineer, shall govern.

K. Periodic site observation by field representatives of JQ is solely for the purpose of determining if the work is proceeding in accordance with the structural contract documents. This limited site observation is not intended to be a check of the quality or quantity of the work, but rather a periodic check in an effort to inform the owner against defects and deficiencies in the work of the contractor.

CODES & REFERENCED REPORTS

A. The General Building Code used as the basis for the structural design is as follows:

1. International Building Code, 2021 Edition

2. International Existing Building Code, 2021 Edition

B. Structural Concrete: Building Code Requirements for Reinforced Concrete, American Concrete Institute, ACI 318, as referenced by the General Building Code.

C. Brick Masonry: Recommended Practice for Engineered Brick Masonry, Brick Institute of America, as referenced by the General Building Code.

D. Wood Framing: National Design Specifications for Wood Construction with Supplement, National Forest and Paper Products Association, as referenced by the General Building Code.

E. Structural Plywood: Plywood Design Specification, American Plywood Association, as referenced by the General Building Code.

F. Geotechnical Report: Foundation elements have been designed in accordance with information provided in the following geotechnical report:

Geotechnical engineer: CQC Testing and Engineering, LLC Report Number: AGCQC20-038 Date: 11-Dec-20

DESIGN LOADS

A. Dead Loads include the self-weight of the structural elements and the following superimposed loads:

1. Ceiling and Mechanical 5 psf

2. Roofing and rigid insulation 8 psf

B. Live Loads

OCCUPANCY OR USE UNIFORM CONCENTRATED

(psf) (lbs.)

1. Partitions at areas with Live Load of 80 psf or less

15 N/A

2. Office 50 2000

3. Public 100 2000

4. Roof 20 N/A

C. Live Load Reduction

1. Live loads have been reduced on any member supporting more than 150 square feet, including flat slabs, except for floors in places of public assembly and for live loads greater than 100 pounds per square foot in accordance with the following formula:

a. r(A-150) >= R >= 23.1(1+D/L)

Where R = Reduction in percent.

r = Rate of reduction equal to .08 percent for floors.

A = Area of floor supported by the member.

D = Total dead load supported by the member.

L = Total unreduced live load supported by the member.

b. The reduction, R, shall not exceed 40 percent for members supporting one level only, 60 percent for other members, or R as calculated in the following formula:

2. Live loads exceeding 100 pounds per square foot have not been reduced, except columns supporting 2 or more stories, live loads have been reduced 20 percent.

3. Roof live load has been reduced using the formula 20 x R1 x R2 according to the General Building Code.

D. Snow loads

1. Ground snow load, Pg 5 psf

E. Wind loads

1. Wind lateral load on structural frame is based on ASCE 7-16 using the following:

a. Ultimate Design Wind Speed Vult 115 mph

b. Nominal Design Wind Speed Vasd 89 mph

c. Exposure C

d. Internal Pressure Coefficient, Gcpi +/-0.18

e. Risk Category II

SUBMITTALS

A. Shop drawings shall be prepared for all structural items and submitted for review by the Engineer. All items deviating from the Structural Drawings or from previously submitted shop drawings shall be clouded.

B. Contractor shall review shop drawings for compliance with the Structural Drawings and shall certify that they have done so by a stamp noting that the drawings have been "Approved" and which bears the signature (or initials) of an authorized representative of the Contractor and the date. Submittals which do not reflect the Contractor's approval, signature and date will be returned without review.

C. Contractor shall be responsible for delays caused by rejection of inadequate shop drawings.

D. Where review and return of shop drawings is required or requested, the Engineer will review each submittal and, where possible, return within two

(2) weeks of receipt.

E. Corrections or comments on shop drawings or manufacturer's data sheets do not relieve the Contractor from compliance with requirements of the plans and specifications. Engineer's review is for general conformance with the requirements of the Structural Drawings. Contractor is responsible for confirming and correcting all quantities and dimensions, selecting fabrication processes and techniques of construction, and coordinating the work with that of all other contractors.

F. Refer to individual sections for specific submittal requirements.

EXCAVATION PROTECTION

A. Temporary retention or alternative protective systems shall be designed to resist the soil pressures stipulated in the referenced geotechnical report. In addition, the design shall consider surcharges created by construction equipment, excavation spoil, and other surface encumbrances.

B. Contractor shall comply with all Occupational Safety and Health Administration standards and all other regulatory agency standards regarding excavation safety.

CONTROLLED BACKFILL PLACED AGAINST PERIMETER WALLS

A. On site materials can be used as backfill.

B. Fill shall be placed in lifts not to exceed 8".

C. Fill shall be compacted to a minimum of 95 percent of the maximum dry density at a moisture content within plus or minus 2 percentage points of optimal moisture as determined by ASTM D698.

D. Compaction and moisture content of controlled backfill shall be verified by an independent testing laboratory.

E. Backfill material shall not be placed against foundation walls until all framing at the first floor has been connected to the walls.

F. Compaction and moisture content of subgrade and each lift of structural fill shall be inspected and approved by a qualified engineering technician, supervised by a Geotechnical Engineer.

CONCRETE FOOTINGS

A. Concrete footing design is based on an allowable net bearing capacity of 500 psf in accordance with the referenced geotechnical report.

B. Bearing stratum shown on the footing details is natural subsoil.

C. Footings not specifically located on the plan shall be located on centerline of walls.

D. Footing excavations shall be to neat lines and shall be free of loose or wet materials.

E. Footing reinforcing and concrete shall be placed immediately after excavations are complete; in no case shall a footing be excavated that cannot be placed by the end of the workday.

F. All footings shall be inspected by a qualified geotechnical inspector in order to ensure that the proposed bearing material has been reached in accordance with the recommendations given in the referenced geotechnical report and that the footing has been constructed to specified size, with detailed reinforcing, and to specified tolerances.

CAST-IN-PLACE CONCRETE

A. CONCRETE MIX USAGE SCHEDULE:

All concrete shall conform to the requirements as specified in the table below, unless noted otherwise on the Structural Drawings:

Use Strength psiAgg.

Type

Agg.

Size

Max w/c

Exposure Class

Footings, Elevator Pit Walls 3000 NWT 1" ----- F0

1. "NWT" refers to normal concrete having air dry unit weight of approximately 145 PCF (ASCE C33 aggregate)

2. The w/c ratio shall be selected by the concrete provider to meet the strength requirements and shall not exceed w/c ratio = 0.55. Where the maximum w/c ratio is indicated in the table above, it shall not be exceeded.

3. "Strength" is required compressive cylinder strength at an age of 28 days.

4. Concrete slump shall be selected by concrete provider to meet strength requirements and workability required for the concrete placement. Slump shall not exceed 9" for any mix and meet the requirements of the ACI.

B. A maximum of 20% of the cementitious materials used in mix designs may be replaced with class C or F fly ash.

C. Horizontal construction joints in concrete placements shall be permitted only where indicated on the Structural Drawings. All vertical construction joints shall be made in the center of spans in accordance with the typical details.

Contractor shall submit proposed locations for construction joints not shown on the Structural Drawings for review by the Architect and Engineer. Additional construction joints may require additional reinforcing as specified by the Engineer which shall be provided by the contractor at no additional cost to the owner.

D. Embedded conduits, pipes, and sleeves shall meet the requirements of ACI 318, Section 26.8, including the following:

1. Conduits and pipes embedded within a slab, wall, or beam (other than those passing through) shall not be larger in outside dimension than 1/3 the overall thickness of the slab, wall or beam in which they are embedded.

2. Conduits, pipes and sleeves shall not be spaced closer than three diameters or widths on center.

E. Submittal: Submit proposed mix designs in accordance with ACI 301, chapter

4.2. Each proposed mix design shall be accompanied by a record of past performance based on at least 30 consecutive strength tests, or by three laboratory trial mixtures with confirmation tests.

CONCRETE REINFORCING

A. Concrete reinforcement for the project shall conform to the following:

1. All reinforcing steel shall be new billet steel in accordance ASTM A615, Grade

60, unless noted otherwise in the Structural Drawings or these notes.

B. Detailing of reinforcing steel shall conform to the American Concrete Institute 315 Detailing Manual and all hooks and bends in reinforcing bars shall conform to ACI detailing standards, unless noted otherwise on the Structural Drawings.

C. Detail reinforcing as follows:

1. Provide Class B lap at other location pending Engineer’s approval.

D. Welding of reinforcing steel will not be permitted unless specifically shown on the Structural Drawings.

E. Heat shall not be used in the fabrication or installation of reinforcement.

F. Reinforcing steel clear cover shall be as follows:

1. Footings 3"

G. Submittal: Submit shop drawings for fabrication, bending, and placement of concrete reinforcement. Comply with ACI 315 "Details and Detailing of Concrete Reinforcement". Do not reproduce the Structural Drawings for use as shop drawings.

STRUCTURAL MASONRY

A. Minimum compressive strength of the masonry (f'm) shall be as noted below.

B. Mortar shall conform to ASTM C270, Type N. Masonry cement shall not be used.

C. Building brick shall conform to ASTM C62, Grade MW. Facing brick shall conform to ASTM C216, Grade MW.

D. Fine grout shall conform to ASTM C476 with a minimum compressive strength of 2000 psi.

E. Chases shall be built in and not cut in. Chases shall be plumb and shall be minimum one unit length from jambs of openings. Anchors, wall plugs, accessories and other items to be built in shall be installed as the masonry work progresses. All cutting and fitting of masonry, including that required to accommodate the work of other sections shall be done by masons with masonry saws.

F. Reinforce concrete masonry unit joints with ladder type hot dip galvanized cold-drawn steel conforming to ANSI/ASTM A82, with W1.7 side rods with W1.7 cross rods.

1. Space joint reinforcing at 16 inches o.c. unless noted otherwise.

2. Lap joint reinforcing 14 inches at splices.

3. Provide prefabricated joint reinforcing corner pieces at all wall corners and intersections.

G. Lap reinforcing bars in grouted masonry a minimum of 36 bar diameters.

H. Embedded conduits, pipes, and sleeves shall meet the requirements of TMS 420, Section 3.2.2, including the following:

1. Conduits, pipes, and sleeves in masonry shall be no closer than 3 diameters on center. Minimum spacing of conduits, pipes or sleeves of different diameters shall be determined using the larger diameter.

2. Vertical conduits, pipes, or sleeves placed in masonry jambs, columns or pilasters shall not displace more than 2 percent of the net cross-sectional area.

a. The net cross-sectional area is the area of masonry units, grout, and mortar.

Ungrouted cells are not considered part of the net cross-sectional area.

I. Provide 1 inch clear cover between ties or longitudinal reinforcing and the inside face of masonry used as forms in grouted beams, pilasters and columns.

J. Helical reinforcing bars in masonry strengthening shall be Helibar by Helifix, or approved equal. Bars shall be 4.5mm (3/16") diameter and material shall comply with ASTM 666, Grade 304 or 316. Install per manufacturer's recommendations.

POST-INSTALLED ANCHORS AND DOWELS

A. Adhesive Anchors:

1. Adhesive Anchors with Threaded Rod:

a. In Solid Stone or Brick Masonry: Adhesive Anchors shall have been tested and qualified in accordance with ICC-ES AC 58. Qualifying anchors shall be one of the following:

1. Acrylic: HIT HY-270 SAFESET (ICC-ES ESR-4143), Hilti, Inc.

2. Acrylic: AT-XP (IAPMO-UES ER-0281), Simpson Strong-Tie Co., Inc.

3. Acrylic: AC 100+Gold (ICC-ES ESR-3200), DEWALT

b. Threaded anchor rod shall be one of the following:

1. Hilti adhesive: "HAS-V-36" (u.n.o), "HAS-E-55", "HAS-B-105" ASTM

F1554 Threaded Rods

2. Simpson adhesive: Steel meeting the requirements of ASTM F1554, grade 36.

3. DEWALT adhesive: Steel meeting the requirements of ASTM A1554, grade 36.

4. Anchor rod shall have a chamfered end on one end to accept a nut and washer; it may have a 45-degree chisel point on the other end.

5. Nuts and washers shall have a proof load strength at least as strong as anchor rod. Stainless steel nuts and washers shall be provided with stainless steel rods.

2. Adhesive Rebar Dowelling:

a. Adhesive doweling systems in concrete shall have been tested and qualified in accordance with ACI 355.4 and ICC-ES AC 308. Qualifying anchors shall be one of the following products, unless specifically noted otherwise on structural drawings:

1. Acrylic: HIT-HY 200 V3 SAFESET (-A/-R) (ICC-ES ESR-4878), Hilti, Inc.

2. Acrylic: SET-XP (ICC-ES ESR-2508), Simpson Strong-Tie Co., Inc.

3. Acrylic: AC 200+ (ICC-ES ESR-4027), DEWALT

B. Anchor and Dowel Installation Requirements

1. Anchors and dowels of the size and embedment shown on the Drawings shall be installed in accordance with the Contract Documents, the manufacturer's recommendations, and the manufacturer's current evaluation (ICC-ES or IAPMO-UES) report for the anchor. If conflicts exist between these referenced documents, the most stringent requirements shall govern.

2. The Contractor shall locate all existing reinforcing steel and other embedded items contained in the concrete using non-destructive methods and shall position anchor locations to avoid conflicts with existing embedded items. Anchor or dowel locations can be adjusted by a maximum of 1 1/2" from detailed locations to avoid conflicts, but shall neither change arrangement nor move closer to a concrete edge.

3. Based on field verified locations of reinforcing steel and embedded items, the Contractor shall create templates for each anchor group. Submit template dimensions for review prior to fabrication of connection plates.

4. Holes for anchors and dowels shall be drilled in a continuous operation using the drill-bit type and size recommended by the anchor manufacturer. Holes shall be drilled perpendicular to the concrete surface and shall not be enlarged or redirected at any point along its length. Holes shall be drilled using a hammer drill, coring shall not be allowed, unless noted otherwise.

5. Oil free compressed air shall be used to blow out the holes unless one of the approved systems noted below is utilized. Unapproved shop vacs, squeeze bulbs, etc. shall NOT be used. Refer to manufacturer's information for detailed cleaning instructions.

a. Hilti SAFESET system with Hilti Hollow Drill Bit and Vacuum System (VC150 or VC300) may be used to eliminate hole cleaning with adhesive anchors.

b. Simpson Speed Clean DXS system may be used to eliminate manual hole cleaning with adhesive anchors.

c. DEWALT Dust X system with hollow drill bit may be used to eliminate manual hole cleaning with adhesive anchors.

6. All abandoned holes shall be filled with non-metallic nonshrink grout capable of reaching a design compressive strength of 5,000 psi at 28 days.

JOINT SEALANT

A. Joint sealant shall be a 2-component, premium-grade, polyurethane-based, elastomeric sealant with a chemical cure. Sealant shall have a self-leveling consistency in horizontal applications, and a non-sag consistency in vertical applications. Sealant color shall be selected by Owner from standard manufacturer colors.

B. All joint surfaces shall be clean, sound and frost-free. Joint walls shall be free of oil, grease, curing compound residues, and any other foreign matter that may prevent bond. Cleaning and preparation of joint surfaces shall be accomplished by mechanical means.

C. Bond breaker tape, closed-cell backer rod or other approved method shall be used in bottom of joint to control depth and to prevent bond to bottom of joint.

D. Thoroughly mix A, B and color pack components in accordance with manufacturer’s instructions to achieve a uniform color and consistency.

E. Pour or extrude sealant in one direction and allow to flow and level as necessary.

Place nozzle of gun into bottom of joint and fill entire joint. Keep the nozzle deep in the sealant and continue with steady flow of sealant preceding nozzle to avoid air entrapment. Do not overlap sealant. Tool joint surface as required.

F. Self-leveling joint sealant shall be Sikaflex -2c SL by Sika Corp. or accepted equal.

G. Non-sag joint sealant shall be Sikaflex -2c NS by Sika Corp. or accepted equal.

H. Submittals: Submit manufacturer’s data sheets and application instructions for review.

S T R U C T U R A L N O T E S

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

STRUCTURAL NOTES

3240186

S100

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

R e v is io n s

R e v

D e s c ri p ti o n

D

SPECIAL INSPECTIONS

A. Special Inspections shall be performed in accordance with Chapter 17 of the 2021 International Building Code (IBC) by a Special Inspector hired by the Owner to perform the Special Inspections listed below. The Special Inspector shall be qualified by an approved agency according to the City's building official to perform the special inspections for which they will be undertaking. The Contractor shall coordinate with and notify the Special Inspector of all tests. The Special Inspector shall be responsible to verify that the items detailed in the Construction Documents were built accordingly and shall prepare, sign, and furnish inspection reports to the building official and the Architect for all time spent at the site. The Inspector shall bring discrepancies to the immediate attention of the General Contractor for correction. If the discrepancies are not corrected, the discrepancies shall be brought to the attention of the building official and to the Architect prior to the completion of that phase of the work. These special inspections are in addition to the other inspections listed in these Structural Notes or Project Specifications.

B. Where structural load-bearing members and assemblies are shop fabricated, the Special Inspector shall verify that the fabricator maintains detailed fabrication and quality control procedures that provide a basis for inspection control of the workmanship and the fabricator's ability to conform to the Construction Documents and Referenced Standards, unless the fabricator is registered and approved to perform such work without special inspection.

C. Job site visits by the structural engineer do not constitute and are not a substitute for special inspections.

D. Architectural, mechanical, and electrical components requiring special inspections and testing per the building code are not listed here.

Refer to architectural, mechanical, and electrical drawings and specifications for requirements for these components.

E. Refer to the general notes and project specifications for additional inspection and testing requirements.

SPECIAL INSPECTIONS AND TESTS SCHEDULED PER IBC 2021

SPECIAL

INSPECTION

REQUIRED

MATERIALS, SYSTEMS, COMPONENTS AND WORK REQUIRED TO

HAVE SPECIAL INSPECTIONS AND/OR TEST BY THE SPECIAL

INSPECTOR RESPONSIBLE FOR EACH PORTION OF THE WORK

REFERENCED

STANDARD

IBC REFRENCE

NO STEEL CONSTRUCTION 1705.2

NO 1. Welding of Structural Steel AISC 360-16 : Table N5.4 1705.2.1 NO 2. Bolting of Structural Steel AISC 360-16 : Table N5.6 1705.2.1 NO 3. Steel Construction Other Than Structural Steel (Metal Deck) SDI QA/QC - 2017 1705.2.2 NO 4. Open-Web Steel Joists and Joist Girders SJI Specs per IBC 2207.1 1705.2.3 NO 5. Composite Construction Prior to Concrete Placement AISC 360-16 : Table N6.1 YES CONCRETE CONSTRUCTION - (Note 1) 1705.3 NO 1. Welding of Reinforcing Bars ACI 318-19 : Sect. 26.6.4 1705.3.1 YES 2. Material Testing ACI 318-19 : Ch. 19 & 20 1705.3.2 YES MASONRY CONSTRUCTION - (Note 1) 1705.4 NO 1. Level 2 Verification and Inspection of Masonry Construction TMS 602-16 : Table 3 & 4 1705.4 YES 2. Level 3 Verification and Inspection of Masonry Construction TMS 602-16 : Table 3 & 4 1705.4

NO WOOD CONSTRUCTION 1705.5

NO 1. High-Load Diaphragms 1705.5.1 NO 2. Metal-Plate-Connected Wood Trusses 1705.5.2 NO 3. Mass Timber Construction 1705.5.3

NO SOILS 1705.6

NO DRIVEN DEEP FOUNDATIONS 1705.7

NO CAST-IN-PLACE DEEP FOUNDATIONS 1705.8

NO HELICAL PILE FOUNDATIONS 1705.9

NO STRUCTURAL INTEGRITY OF DEEP FOUNDATION ELEMENTS 1705.10

NO FABRICATED ITEMS 1705.11

NO SPECIAL INSPECTIONS FOR WIND RESISTANCE 1705.12

NO 1. Structural Wood 1705.12.1 NO 2. Cold-Formed Steel Light-Frame Construction 1705.12.2 NO 3. Wind-Resisting Components 1705.12.3

NO SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE 1705.13

NO 1. Structural Steel AISC 341-16 : Sect. J 1705.13.1 NO a. Seismic Force Resisting System AISC 341-16 : Sect. J 1705.13.1.1 NO b. Structural Steel Elements AISC 341-16 : Sect. J 1705.13.1.2 NO 2. Structural Wood 1705.13.2 NO 3. Cold-Formed Steel Light-Frame Construction 1705.13.3 NO 4. Designated Seismic System 1705.13.4

NO TESTING FOR SEISMIC RESISTANCE 1705.14

NO 1. Structural Steel AISC 341-16 : Sect. J 1705.14.1

YES DESIGN STRENGTH OF MATERIALS 1706

1. Post-Installed anchors and dowels:

a. Visual inspections shall be performed during the installation by a Special Inspector certified by ACI as a "Post-Installed Concrete

Anchor Installation Inspector". Submit a report to the licensed design professional and building official documenting that the work covered by the report has been performed and that the materials used and the installation procedures used conform with the approved construction documents and the Manufacturer's Printed Installation Instructions.

SYMBOLS LEGEND

SYMBOL DESCRIPTION

EXISTING

CONSTRUCTION

EXISTING MASONRY

WALL

WINDOW IN EXIST.

MASONRY WALL

DOOR IN EXIST.

MASONRY WALL

S T R U C T U R A L N O T E S

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M A

G O

F F

IN

A

V E

N U

E , E

L P

A S

O , T

E X

A S

11/19/2024

SPECIAL INSPECTIONS,

ABBREVIATIONS &

SYMBOLS LEGEND

3240186

S101

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

ABV. - ABOVE

A.F.F. - ABOVE FINISHED FLOOR

ADDN'L. - ADDITIONAL

ADH. - ADHESIVE

ADJ. - ADJACENT

AGGR. - AGGREGATE

A/C - AIR CONDITIONER

AHU - AIR HANDLING UNIT

ALT. - ALTERNATE

ALUM. - ALUMINUM

A.C.I. - AMERICAN CONCRETE INSTITUTE

A.I.S.C. - AMERICAN INSTITUE OF STEEL CONSTRUCTION

A.B. - ANCHOR BOLT

& - AND

L - ANGLE

APPD. - APPROVED

APPROX. - APPROXIMATE

ARCH. - ARCHITECT

ARCH'L - ARCHITECTURAL

A.E.C. - ARCHITECTURALLY EXPOSED CONCRETE

A.E.S.S. - ARCHITECTURALLY EXPOSED STRUCTURAL STEEL

@ - AT

B.F. - BACK FACE

B. TO B. - BACK TO BACK

BSMT. - BASEMENT

BM. - BEAM

BRG. - BEARING

B.F.F. - BELOW FINISH FLOOR

BTWN. - BETWEEN

BEV('D) - BEVEL(ED)

BLK. - BLOCK

B.L. - BLOCK LINTEL

BLKG. - BLOCKING

BOT. - BOTTOM

B.O. - BOTTOM OF

B.O.S. - BOTTOM OF STEEL

BRKT. - BRACKET

BR.L. - BRICKLEDGE

BRDG. - BRIDGING

BLDG. - BUILDING

C - CAMBER

C.I.P. - CAST-IN-PLACE

CLG. - CELING

C.L. - CENTER LINE

C.G. - CENTER OF GRAVITY

C.G.S. - CENTER OF GRAVITY OR STRAND

CTR'D. - CENTERED

CLR. - CLEAR OR CLEARANCE

CFS - COLD FORMED STEEL

COL. - COLUMN

C OR

COMP.

- COMPRESSION

CONC. - CONCRETE

CMU - CONCRETE MASONRY UNIT

CONN(S) - CONNECTION(S)

CONST. - CONSTRUCTION

CONST. JT. - CONSTRUCTION JOINT

CONT. - CONTINUOUS

CONTR. - CONTRACTOR

C.J. - CONTROL JOINT

COORD. - COORDINATE

COV. PL. - COVER PLATE

D.L. - DEAD LOAD

D.B.A. - DEFORMED BAR ANCHOR

D. - DEPTH

DTL. - DETAIL

DIAG. - DIAGONAL

DIA OR Ø - DIAMETER

DIM(S). - DIMENSION(S)

DBL. - DOUBLE

XX-STR - DOUBLE EXTRA STRONG

DVTL. - DOVETAIL

DWL(S). - DOWEL(S)

DN. - DOWN

DS. - DOWNSPOUT

DWG(S). - DRAWING(S)

EA. - EACH

E.F. - EACH FACE

E.W. - EACH WAY

E.O.D. - EDGE OF DECK

ELEC. - ELECTRICAL

EL. - ELEVATION

ELEV. - ELEVATOR

EMBED. - EMBEDMENT

ENGR. - ENGINEER

EQ. - EQUAL

EQUIP. - EQUIPMENT

EF - EXHAUST FAN

(E) - EXIST.

EXIST. - EXISTING

EXP. - EXPANSION

E.J. - EXPANSION JOINT

EXT. - EXTERIOR

X-STR - EXTRA STRONG

FABR. - FABRICATOR

F. TO F. - FACE TO FACE

F.S. - FAR SIDE

F.V. - FIELD VERIFY

FIN('D) - FINISH(ED)

FIN. FL. - FINISHED FLOOR

FP. - FIREPROOF(ING)

FLG. - FLANGE

FL. - FLOOR

F.D. - FLOOR DRAIN

FT. - FOOT (OR) FEET

FDN. - FOUNDATION

STRUCTURAL ABBREVIATIONS

FRMG - FRAMING

F.P. - FULL PENETRATION

GA. - GAGE OR GAUGE

GALV. - GALVANIZED

G.C. - GENERAL CONTRACTOR

GR. - GRADE

GR. BM. - GRADE BEAM

H.S.A. - HEADED STUD ANCHOR

HT. - HEIGHT

H.P. - HIGH POINT

HSS - HOLLOW STRUCTURAL SECTION

HK. - HOOK

HORIZ. - HORIZONTAL

H.B. - HORIZONTAL BRACE

H.D. - HOT-DIP

IN. - INCH

INFO. - INFORMATION

I.D. - INSIDE DIAMETER

I.F. - INSIDE FACE

INT. - INTERIOR

INTERM. - INTERMEDIATE

JT. - JOINT

J.G. - JOIST GIRDER

JST(S) - JOIST(S)

KLF - KIP PER LINEAR FOOT

KSF - KIP PER SQUARE FOOT

KSI - KIP PER SQUARE INCH

K - KIPS (1000 LBS)

L. - LENGTH

L.W. - LIGHTWEIGHT

L.W.C. - LIGHTWEIGHT CONCRETE

L.L. - LIVE LOAD

LOC. - LOCATION

LLH - LONG LEG HORIZONTAL

LLV - LONG LEG VERTICAL

LSH - LONG SIDE HORIZONTAL

LSV - LONG SIDE VERTICAL

LSL - LONG SLOTTED HOLE

LONG - LONGITUDINAL

L.P. - LOW POINT

MFR. - MANUFACTURE(R)

MAS. - MASONRY

MAT. - MATERIAL

MAX. - MAXIMUM

MECH. - MECHANICAL

MEP - MECHANICAL, ELECTRICAL, PLUMBING

MTL. - METAL

MEZZ. - MEZZANINE

MID. - MIDDLE

MIN. - MINIMUM

MISC. - MISCELLANEOUS

M - MOMENT

M.C. - MOMENT CONNECTION(S)

N.F. - NEAR FACE

NOM. - NOMINAL

N.S. - NON-SHRINK

N/A - NOT APPLICABLE

N.I.C. - NOT IN CONTRACT

N.T.S. - NOT TO SCALE

NO. OR # - NUMBER

O.C. - ON CENTER

OPNG(S) - OPENING(S)

OPP. - OPPOSITE

O.H. - OPPOSITE HAND

O.D. - OUTSIDE DIAMATER

O.F. - OUTSIDE FACE

OVS - OVER-SIZED HOLE

P - PAN

P.J. - PANEL JOINT

PAR. - PARALLEL

PERP. - PERPENDICULAR

PC. - PIECE

PL. - PLATE

PT. - POINT

P-T - POST-TENSION(ED)

# OR LBS. - POUNDS

PCF - POUNDS PER CUBIC FOOT

PLF - POUNDS PER LINEAR FOOT

PSF - POUNDS PER SQUARE FOOT

PSI - POUNDS PER SQUARE INCH

P.E.M.B. - PRE-ENGINEERED METAL BUILDING

P/C - PRECAST CONCRETE

PREFAB. - PREFABRICATED

PRELIM. - PRELIMINARY

P.T. - PRESSURE TREATED

PROJ. - PROJECTION

QTY. - QUANTITY

R - RADIUS

REINF. - REINFORCE(ING)(ED)(MENT)

RCP - REINFORCED CONCRETE PIPE

REM. - REMAINDER

REQ. - REQUIRE

REQ'D. - REQUIRED

RET. SYS. - RETENTION SYSTEM

RIS. - RISER

RF. - ROOF

R.D. - ROOF DRAIN

R.T.U. - ROOF TOP UNIT

RM. - ROOM

R.O. - ROUGH OPENING

RND. - ROUND

SCHED. - SCHEDULE(D)

SECT. - SECTION

V - SHEAR

SHT. - SHEET

SSL - SHEET SHORT SLOTTED HOLE

SW - SIDEWALK

SIM. - SIMILAR

S.O.G. - SLAB ON GRADE

SPA. - SPACE

SPEC(S) - SPECIFICATION(S)

SPEC'D - SPECIFIED

SQ. - SQUARE

S.F. - SQUARE FOOT

STAGG. - STAGGERED

S.S. - STAINLESS STEEL

STD. - STANDARD

STL. - STEEL

S.J.I. - STEEL JOIST INSTITUE

STIFF - STIFFENER

STIRR. - STIRRUPS

STR. - STRAIGHT

STRUCT'L - STRUCTURAL

STRUCT. - STRUCTURE

SUBCONTR. - SUBCONTRACTOR

SUPT(S). - SUPPORT(S)

TEMP. - TEMPERATURE

T - TENSION

TERR. - TERRAZZO

THK. - THICK

THRD. - THREAD(ED)

T&G - TONGUE AND GROOVE

T&B - TOP AND BOTTOM

T.O. - TOP OF

T.O.B. - TOP OF BEAM

T.O.C. - TOP OF CONCRETE

T.O.F. - TOP OF FOOTING

T.O.J. - TOP OF JOIST

T.O.P. - TOP OF PIER

T.O.P.C. - TOP OF PIER (PIPE) CAP

T.O.S. - TOP OF STEEL

T.O.W. - TOP OF WALL

TRANSV. - TRANSVERSE

TR. - TREAD

TYP. - TYPICAL

U.N.O. - UNLESS NOTED OTHERWISE

VERT. - VERTICAL

V.B. - VERTICAL BRACE

WPFG. - WATERPROOFING

WS. - WATERSTOP

WT. - WEIGHT

W.W.M. - WELDED WIRE MESH

W. - WIDTH

W.L. - WIND LOAD

WDW. - WINDOW

W/ - WITH

W/O - WITHOUT

W.D. - WOOD

W.P. - WORK POINT

R e v is io n s

R e v

D e s c ri p ti o n

D

NEW FOOTING

S200

BASEMENT

'-6

FINISH -

SEE ARCH'L

CRAWL SPACE

EXIST. SECOND FLOOR &

ROOF FRAMING

CONTRACTOR SHALL CONFIRM

COURSING & LAYOUT PRIOR TO

PLACING WALL JOINT

REINFORCEMENT

1'-4" MAX.

SPACING

C

O U

R S

E D

O W

N H

IG

H

E S

T J

O

IN

T R

E

IN

F

1'-

3/ 4"

2/S400

1/S400

HORIZONTAL JOINT

REINF. - TYP.

'-6

6"

1'-0" 6"

BACKFILL - REFER

TO STRUCT'L NOTES

C

O U

R S

E S

U P

L O

W E

S T

J O

IN

T

R E

IN

F

#4 @ 10" O.C.

EACH WAY

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

BASEMENT AND CRAWL

SPACE FOUNDATION

PLAN

3240186

S200

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

SCALE: 1/4" = 1'-0"

1 BASEMENT & CRAWL SPACE FOUNDATION PLAN

SCALE: 1/2" = 1'-0"

2 WALL REPLACEMENT

plan north true north

R e v is io n s

R e v

D e s c ri p ti o n

D

4/S500

2/S500

3/S500

S201

S200

5/S500

1' -2

3' -2

'-9

'-1

'-9

9"

3'-2"

10"

NOTE: FIELD VERIFY

ALL DIMENSIONS

4" 1"TYP.

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

FIRST FLOOR FRAMING

PLAN

3240186

S201

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

SCALE: 1/4" = 1'-0"

1 FIRST FLOOR FRAMING PLAN

SCALE: 3/4" = 1'-0"

2 ENLARGED FRAMING PLAN

plan north true north plan north true north

R e v is io n s

R e v

D e s c ri p ti o n

D

S200

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

SECOND FLOOR AND

ATTIC FRAMING PLAN

3240186

S202

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

SCALE: 1/4" = 1'-0"

1 SECOND FLOOR AND ATTIC FRAMING PLAN

plan north true north

R e v is io n s

R e v

D e s c ri p ti o n

D

S200

NEW WALL

NEW FOOTINGBASEMENT

RECONSTRUCT CRACKED

STONE WALL. RESET STONE

IN SAME LOCATIONS AS

EXISTING - SEE 1/S500

S500

TYP. 5

S500

TYP.

4/S500

5/S500

EXISTING

FOUNDATION

SEALANT REPLACEMENT -

SEE STRUCT'L NOTES

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

BUILDING ELEVATIONS

3240186

S300

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

SCALE: 1/4" = 1'-0"

1 WEST ELEVATION

NOTE:

1. PAINT FULL WIDTH OF WEST ELEVATION TO MATCH EXISTING.

R e v is io n s

R e v

D e s c ri p ti o n

D

4" x 14 GA. x 3" GALV. STEEL CLIP ATTACH TO FLOOR JOIST W/ 2-#9 x

1 1/2" HEX HEAD WOOD SCREWS.

ATTACH TO EXISTING BRICK WALL

W/ 1-1/4" DIA. x 6" HEX HEAD CONC.

SCREW

3"

EXISTING FLOOR FRAMING

EXISTING STONE WALL

NEW BRICK MASONRY WALL

NOTES:

1. CONNECTION SHALL BE INSTALLED AT EVERY FLOOR JOIST.

2. DETAIL APPLIES AT LOCATIONS WHERE FIRST FLOOR JOISTS

SPAN PERPENDICULAR TO EXTERIOR WALL.

1x4 SILL PLATE

T Y

P

#3 X 2'-0" ADH. ANCHOR

INTO EXISTING PER

STRUCTURAL NOTE.

PLACE TO MATCH VERT.

REINFORCING PER 2/S200

EXISTING 2x10 @ 24" O.C.

NEW BRICK

MASONRY WALL

NOTES:

1. CONNECTION SHALL BE INSTALLED AT EVERY FLOOR JOIST.

2. DETAIL APPLIES AT LOCATIONS WHERE SECOND FLOOR JOISTS

SPAN PERPENDICULAR TO EXTERIOR WALL.

EXIST. 1x4

EXISTING 1x8 SILL PLATE

EXTERIOR INTERIOR

EXIST. 2x RAFTERS

EXIST. SKIP SHEATHING

EXIST. OVER DECK

EXIST GUTTER

EXIST. FASCIA TO REMAIN -

TYP.

DISMANTLE EXIST. WOOD SOFFIT FOR

STRUCTURAL REPAIRS. REINSTALL,

REPAIR AND REPAINT

EXIST FLASHING

NEW 2x FULL DEPTH BLOCKING

NAIL TO EXISTING JOISTS

8" x 14 GA. x 3" GALV. STEEL CLIP

ATTACH TO EXISTING FLOOR JOIST

W/ 2-#9 x 1 1/2" HEX HEAD WOOD SCREWS.

ATTACH TO BRICK WALL W/ 1-1/4" DIA. x 9"

THREADED ROD SET W/ HILTI HIT-HY270

ADHESIVE WITH 2 SCREEN TUBES TO

MINIMUM 6" EMBEDMENT

3"

HELICAL BAR PLACEMENT:

1. HELICAL BARS SHALL BE PLACED IN BED JOINTS, NOT MORE THAN 2 COURSES

FROM ENDS OF CRACK.

2. PROVIDE NO LESS THAN 2 HELICAL BARS PER CRACK.

3. NO MORE THAN 4 COURSES VERTICALLY BETWEEN HELICAL BARS.

REPOINT CRACKED AND OPEN

HEAD AND BED JOINTS AT CRACK,

TYP.

HELICAL BAR REINFORCEMENT

2'-0" MIN.

2'-0" MIN.

HELICAL BAR FULLY BEDDED IN

FIRST LIFT OF POINTING MORTAR

RAKE JOINTS TO 1" DEPTHS &

REPOINT IN 3 LIFTS WITH

HELICAL BAR

EXIST. BRICK - TYP.

HELICAL JOINT REINF.

EVERY SIX (6) BRICK

COURSES - SEE

STRUCT'L NOTES

EXISTING

WALL

NEW

W

ALL

1'-0" MAX.

1'-0 " M

AX.

PLAN

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

STRUCTURAL DETAILS

3240186

S400

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

NO SCALE

TYPICAL FIRST FLOOR

JOIST CONNECTION DETAIL

NO SCALE

TYPICAL SECOND FLOOR

JOIST CONNECTION DETAIL

SCALE: 1 1/2" = 1'-0"

3 CRACK REPAIR WITH HELICAL BARS DETAIL

NO SCALE

4 HELICAL BAR REINFORCED JOINT

NO SCALE

5 HELICAL BAR REINFORCEMENT DETAIL

R e v is io n s

R e v

D e s c ri p ti o n

D

RECONSTRUCT STONE

WALL. RESET STONE IN

SAME LOCATIONS AS EXIST.

CRACK REPAIR -

SEE 3/S400

CRACK REPAIR -

SEE 3/S400

SEALANT REPAIR - SEE

STRUCTURAL NOTES

SEALANT REPAIR - SEE

STRUCTURAL NOTES

(NOT INTENDED FOR BIDDING,

PERMIT OR CONSTRUCTION

PURPOSES)

REVIEW

INTERIM

DOCUMENTS

DATE:

JQ

IN

FR

AS

TR

U

CT

U

RE

, L

LC

G

LA

SS

S

TR

EE

T, S U

IT

E

2.

2.

D

AL

LA

S, T

EX

AS

TB

PE

F

IR

M F

-7

JQ

IE

N G

.C O

M

Date:

Project No.:

Sheet Title:

Drawing No.:

sh ap in g th e bu ilt e nv iro nm en t

In fr a s tr u c tu re

11/19/2024

STEPHEN H. LUCY

TEXAS REGISTRATION No:62420

V

IS

IT

O

R C

E N

T E

R

S T

R U

C T

U R

A L

A

R C

H

IT

E C

T U

R A

L R

E P

A

IR

S

M

A G

O F

F

IN

A V

E N

U E

E

L P

A S

O T

E X

A S

11/19/2024

PHOTOGRAPHS

3240186

S500

T E

X A

S H

IS

T

O R

IC

A

L C

O M

M

IS

S

IO

N M

A G

O F

F

IN

H O

M E

S T

A T

E H

IS

T

O R

IC

S

IT

E

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

U B

M

IS

S

IO

N

N O

T F

O R

R E

G U

L A

T O

R Y

A P

P R

O V

A L

P

E R

M

IT

T

IN

G O

R C

O N

S T

R U

C T

IO

N

NO SCALE

1 PHOTOGRAPH

NO SCALE

2 PHOTOGRAPH

NO SCALE

3 PHOTOGRAPH

NO SCALE

4 PHOTOGRAPH

NO SCALE

5 PHOTOGRAPH

R e v is io n s

R e v

D e s c ri p ti o n

D

DN

UP

BREAK ROOM

CLASSROOM/

PORCH

FRONT

GIFT SHOP

OFFICE /

RECEPTION

EXHIBIT

MEETING

MEN

WOMEN

ALCOVE

STORAGE

JANITOR/

PORCH

REAR

RAMP

STAIR

FIN. FLR. ELEV.

=0'-0"

EXTERIOR BRICK REMOVAL

(REF. STRUCTURAL) TO

OCCUR AFTER BUILDING

ELEMENTS IDENTIFIED IN

01/A411 TO BE SALVAGED

FOR REINSTALLATION HAVE

BEEN REMOVED

01/A411

SCALE:

FIRST FLOOR DEMOLITION PLAN01 1/4"=1'-0"

PLAN

NORTH

12821 40

JQ

INF

RA

STR

UC

TU

RE

, LL

C

0 G

LA

SS

STR

EET

, SU

ITE

2.3

.73

DA

LLA

S, T

EX

AS

TB

PE

FIR

M

F-7

JQ

IEN

G.C

OM

Date:

Project No.:

Sheet Title:

Drawing No.:

In fra str uc tu re

VI

SI

TO

R'

S

CE

NT

ER

ST

RU

CT

UR

AL

AR

CH

IT

EC

TU

RA

L R

EP

AI

RS

M

AG

OF

FI

N

AV

EN

UE

, E

L

PA

SO

, T

EX

AS

R ev is io ns

R ev

D es cr ip tio n

D at e

TE

XA

S

HI

ST

OR

IC

AL

C

OM

M

IS

SI

ON

M

AG

OF

FI

N

HO

M

E

ST

AT

E

HI

ST

OR

IC

S

IT

E

HP17066.2401.00

11/18/2024

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IS

SI

O

N

N O

T

FO

R R

EG

U

LA

TO

R Y

AP

PR

O

VA

L, P

ER

M

IT

TI

N G

, O R

C O

N

ST

R U

C

TI

O N

FIRST FLOOR

DEMOLITION PLAN

AD101

GENERAL NOTES DEMOLITION PLANS

1. REFER ALSO TO GENERAL PROJECT NOTES.

2. REFER TO STRUCTURAL DRAWINGS.

3. REFERENCE OTHER DISCIPLINES FOR ADDITIONAL

DEMOLITION WORK, AND FOR WORK THAT MAY

REQUIRE DEMOLITION OF ARCHITECTURAL

ELEMENTS.

4. DURING DEMOLITION OPERATIONS, SALVAGE FOR

REUSE BUILDING ELEMENTS AND MATERIALS AS

INDICATED.

DEMOLITION LEGEND

ELEMENT TO BE REMOVED

EXISTING WALLS TO REMAIN

AutoCAD SHX Text shaping the built environment

UP

BREAK ROOM

CLASSROOM/

PORCH

FRONT

GIFT SHOP

OFFICE /

RECEPTION

EXHIBIT

MEETING

MEN

WOMEN

ALCOVE

STORAGE

JANITOR/

PORCH

REAR

RAMP

STAIR

FIN. FLR. ELEV.

=0'-0"

RECONSTRUCT EXTERIOR

BRICK WALL (REF.

STRUCTURAL) AND

REINSTALL SALVAGED

WOOD WINDOW AND FRAME

TO CREATE WEATHERTIGHT

ENCLOSURE PRIOR TO

PERFORMING INTERIOR

WORK IDENTIFIED IN 02

THROUGH 10/A411

02/A411

RC

/A

08/A401

/A

05/A401

07/A401

04/A401

/A

01/A401

03/A401

SCALE:

FIRST FLOOR PLAN01 1/4"=1'-0"

PLAN

NORTH

12821 40

JQ

INF

RA

STR

UC

TU

RE

, LL

C

0 G

LA

SS

STR

EET

, SU

ITE

2.3

.73

DA

LLA

S, T

EX

AS

TB

PE

FIR

M

F-7

JQ

IEN

G.C

OM

Date:

Project No.:

Sheet Title:

Drawing No.:

In fra str uc tu re

VI

SI

TO

R'

S

CE

NT

ER

ST

RU

CT

UR

AL

AR

CH

IT

EC

TU

RA

L R

EP

AI

RS

M

AG

OF

FI

N

AV

EN

UE

, E

L

PA

SO

, T

EX

AS

R ev is io ns

R ev

D es cr ip tio n

D at e

TE

XA

S

HI

ST

OR

IC

AL

C

OM

M

IS

SI

ON

M

AG

OF

FI

N

HO

M

E

ST

AT

E

HI

ST

OR

IC

S

IT

E

HP17066.2401.00

11/18/2024

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IS

SI

O

N

N O

T

FO

R R

EG

U

LA

TO

R Y

AP

PR

O

VA

L, P

ER

M

IT

TI

N G

, O R

C O

N

ST

R U

C

TI

O N

FIRST FLOOR

PLAN

A101

RESTORATION LEGEND

REPAIR CRACKRC

GENERAL NOTES FLOOR PLANS

1. SEAL AROUND PENETRATIONS LEFT IN EXTERIOR

WALLS, FLOORS AND ROOF.

2. RESTORE EXTERIOR MATERIALS, EXCEPT WHERE

NOTED OTHERWISE.

LEGEND

WALL OR PARTITION

EXISTING WALLS TO REMAIN

ATTIC

STORAGE

ARCHIVE

FILE STORAGE

RESEARCH/

OFFICE

OFFICE

ATTIC

UNFINISHED

ATTIC

STORAGE

STORAGE

STAIR

FIN. FLR. ELEV.

=12'-8"

RC

REMOVE TEMPORARY

WOOD SHORING PRIOR TO

PERFORMING INTERIOR

WORK IDENTIFIED IN 02

THROUGH 10/A411; PATCH

MATERIALS AS NEEDED

PLAN

NORTH

12821 40

JQ

INF

RA

STR

UC

TU

RE

, LL

C

0 G

LA

SS

STR

EET

, SU

ITE

2.3

.73

DA

LLA

S, T

EX

AS

TB

PE

FIR

M

F-7

JQ

IEN

G.C

OM

Date:

Project No.:

Sheet Title:

Drawing No.:

In fra str uc tu re

VI

SI

TO

R'

S

CE

NT

ER

ST

RU

CT

UR

AL

AR

CH

IT

EC

TU

RA

L R

EP

AI

RS

M

AG

OF

FI

N

AV

EN

UE

, E

L

PA

SO

, T

EX

AS

R ev is io ns

R ev

D es cr ip tio n

D at e

TE

XA

S

HI

ST

OR

IC

AL

C

OM

M

IS

SI

ON

M

AG

OF

FI

N

HO

M

E

ST

AT

E

HI

ST

OR

IC

S

IT

E

HP17066.2401.00

11/18/2024

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IS

SI

O

N

N O

T

FO

R R

EG

U

LA

TO

R Y

AP

PR

O

VA

L, P

ER

M

IT

TI

N G

, O R

C O

N

ST

R U

C

TI

O N

SCALE:

SECOND FLOOR PLAN01 1/4"=1'-0"

SECOND FLOOR

PLAN

A102

RESTORATION LEGEND

REPAIR CRACKRC

GENERAL NOTES FLOOR PLANS

1. SEAL AROUND PENETRATIONS LEFT IN EXTERIOR

WALLS, FLOORS AND ROOF.

2. RESTORE EXTERIOR MATERIALS, EXCEPT WHERE

NOTED OTHERWISE.

LEGEND

WALL OR PARTITION

EXISTING WALLS TO REMAIN

11'-8"

11'-8"

11'-8"

11'-8"

8'-0"

10'-0"

11'-8"

10'-0"

9-6"

BREAK ROOM

CLASSROOM/

PORCH

FRONT

GIFT SHOP

OFFICE /

RECEPTION

EXHIBIT

MEETING

MEN

WOMEN

ALCOVE

STORAGE

JANITOR/

PORCH

REAR

STAIR

VARIES

RC

RC

RC

RC

RC

RC

RC

RC

REMOVE TEMPORARY

WOOD SHORING PRIOR TO

PERFORMING INTERIOR

WORK IDENTIFIED IN 02

THROUGH 10/A411; PATCH

ANY DAMAGE AS NEEDED

SCALE:

FIRST FLOOR RCP01 1/4"=1'-0"

PLAN

NORTH

12821 40

JQ

INF

RA

STR

UC

TU

RE

, LL

C

0 G

LA

SS

STR

EET

, SU

ITE

2.3

.73

DA

LLA

S, T

EX

AS

TB

PE

FIR

M

F-7

JQ

IEN

G.C

OM

Date:

Project No.:

Sheet Title:

Drawing No.:

In fra str uc tu re

VI

SI

TO

R'

S

CE

NT

ER

ST

RU

CT

UR

AL

AR

CH

IT

EC

TU

RA

L R

EP

AI

RS

M

AG

OF

FI

N

AV

EN

UE

, E

L

PA

SO

, T

EX

AS

R ev is io ns

R ev

D es cr ip tio n

D at e

TE

XA

S

HI

ST

OR

IC

AL

C

OM

M

IS

SI

ON

M

AG

OF

FI

N

HO

M

E

ST

AT

E

HI

ST

OR

IC

S

IT

E

HP17066.2401.00

11/18/2024

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IS

SI

O

N

N O

T

FO

R R

EG

U

LA

TO

R Y

AP

PR

O

VA

L, P

ER

M

IT

TI

N G

, O R

C O

N

ST

R U

C

TI

O N

FIRST FLOOR

REFLECTED CEILING PLAN

A151

RESTORATION LEGEND

REPAIR CRACKRC

7'-10 1/4"

7'-10 3/4"

7'-10 3/4"

VARIES

VARIES VARIES

7'-10 1/4"

ATTIC

STORAGE

ARCHIVE

FILE STORAGE

RESEARCH/

OFFICE

OFFICE

ATTIC

UNFINISHED

ATTIC

STORAGE

STORAGE

STAIR

VARIES

VARIES

VARIES

VARIES

RC

RC

RC

REMOVE TEMPORARY

WOOD SHORING PRIOR TO

PERFORMING INTERIOR

WORK IDENTIFIED IN 02

THROUGH 10/A411; PATCH

ANY DAMAGE AS NEEDED

PLAN

NORTH

12821 40

JQ

INF

RA

STR

UC

TU

RE

, LL

C

0 G

LA

SS

STR

EET

, SU

ITE

2.3

.73

DA

LLA

S, T

EX

AS

TB

PE

FIR

M

F-7

JQ

IEN

G.C

OM

Date:

Project No.:

Sheet Title:

Drawing No.:

In fra str uc tu re

VI

SI

TO

R'

S

CE

NT

ER

ST

RU

CT

UR

AL

AR

CH

IT

EC

TU

RA

L R

EP

AI

RS

M

AG

OF

FI

N

AV

EN

UE

, E

L

PA

SO

, T

EX

AS

R ev is io ns

R ev

D es cr ip tio n

D at e

TE

XA

S

HI

ST

OR

IC

AL

C

OM

M

IS

SI

ON

M

AG

OF

FI

N

HO

M

E

ST

AT

E

HI

ST

OR

IC

S

IT

E

HP17066.2401.00

11/18/2024

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IS

SI

O

N

N O

T

FO

R R

EG

U

LA

TO

R Y

AP

PR

O

VA

L, P

ER

M

IT

TI

N G

, O R

C O

N

ST

R U

C

TI

O N

SCALE:

SECOND FLOOR RCP01 1/4"=1'-0"

SECOND FLOOR

REFLECTED CEILING PLAN

A152

RESTORATION LEGEND

REPAIR CRACKRC

SCALE:

EXHIBIT - 10304

3/8"=1'-0"

SCALE:

BREAK ROOM - 10908

3/8"=1'-0"SCALE:

BREAK ROOM - 10909

3/8"=1'-0"

SCALE:

MEETING - 10405

3/8"=1'-0"

SCALE:

MEETING - 10407

3/8"=1'-0"

SCALE:

MEETING - 10406

3/8"=1'-0"

SCALE:

GIFT SHOP - 10203

3/8"=1'-0" SCALE:

RECEPTION - 10101

3/8"=1'-0"SCALE:

RECEPTION - 10102

3/8"=1'-0"

RC

RC

RC

RC

RC

RC

RC

RC

RC

RC

RC

RC

RCRC RC

JQ

INF

RA

STR

UC

TU

RE

, LL

C

0 G

LA

SS

STR

EET

, SU

ITE

2.3

.73

DA

LLA

S, T

EX

AS

TB

PE

FIR

M

F-7

JQ

IEN

G.C

OM

Date:

Project No.:

Sheet Title:

Drawing No.:

In fra str uc tu re

VI

SI

TO

R'

S

CE

NT

ER

ST

RU

CT

UR

AL

AR

CH

IT

EC

TU

RA

L R

EP

AI

RS

M

AG

OF

FI

N

AV

EN

UE

, E

L

PA

SO

, T

EX

AS

R ev is io ns

R ev

D es cr ip tio n

D at e

TE

XA

S

HI

ST

OR

IC

AL

C

OM

M

IS

SI

ON

M

AG

OF

FI

N

HO

M

E

ST

AT

E

HI

ST

OR

IC

S

IT

E

HP17066.2401.00

11/18/2024

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IS

SI

O

N

N O

T

FO

R R

EG

U

LA

TO

R Y

AP

PR

O

VA

L, P

ER

M

IT

TI

N G

, O R

C O

N

ST

R U

C

TI

O N

INTERIOR ELEVATIONS

A401

RESTORATION LEGEND

REPAIR CRACKRC

821 40

SALVAGED

GRAB BARS

SALVAGED

TOILET PAPER

DISPENSER

SCALE:

WOMEN - 10703

3/8"=1'-0"

SCALE:

MEN - 10807

3/8"=1'-0"

SCALE:

WOMEN - 10706

3/8"=1'-0"

SCALE:

MEN - 10810

3/8"=1'-0"

SCALE:

WOMEN - 10705

3/8"=1'-0"

SCALE:

MEN - 10809

3/8"=1'-0"

SCALE:

WOMEN - 10704

3/8"=1'-0"

SCALE:

MEN - 10808

3/8"=1'-0"

TILE WAINSCOT,

TYP.

SALVAGED VANITY

AND PLASTIC

LAMINATE

COUNTERTOP

SALVAGED SURFACE

MOUNTED MIRROR

SALVAGED TOILET

PARTITION

TILE WAINSCOT,

TYP.

SALVAGED VANITY

AND PLASTIC

LAMINATE

COUNTERTOP

SALVAGED…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .