Elevator_Modernization_Drawings.pdf

PDF 7 MB Posted

Attached to
EMERGENCY BID for Orange County Courthouse Elevator Modernization
Solicitation number
Y24-796
Issued by
Orange County, Orlando City, Florida

About this file

These detailed construction documents are for the Orange County Courthouse Elevator Modernization project located in Orlando, Florida, prepared by KMF Architects and dated November 8, 2023. The project involves a comprehensive modernization of 20 elevators, specifically 19 traction type and 1 hydraulic type elevators within the courthouse complex at 425 N Orange Ave. The comprehensive design documents include architectural plans, electrical site plans, renovation plans for various building levels (basement, levels 22 and 24.5, and building penthouses), electrical schedules, and detailed elevator cab interior and exterior elevation specifications.

The project documents specify compliance with multiple building and safety codes, including the 2020 Florida Building Codes, National Electric Code (2017), National Fire-Alarm Code (2016), Florida Fire Prevention Code (2020), Life Safety Code, and federal OSHA standards. The drawings provide extensive technical details for elevator modernization, including electrical connections, lighting fixtures, renovation plans for different building sections, and specific requirements for elevator cab interior finishes, control panels, and electrical systems. The comprehensive set of drawings indicates a complex, multi-phase renovation effort designed to update and standardize the courthouse's vertical transportation infrastructure while maintaining stringent safety and performance standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T001

COVER SHEET

ORANGE COUNTY

COURTHOUSE ELEVATOR

MODERNIZATION

f2020-331

ORANGE COUNTY COURT HOUSE

425 N ORANGE AVE, ORLANDO, FL 32801

ORANGE COUNTY COURT HOUSE ELEVATOR MODERNIZATION

NOVEMBER 8, 2023

100% CONSTRUCTION DOCUMENTS

OWNER:

BOARD OF COUNTY COMMISSIONERS

ORANGE COUNTY, FLORIDA

MAYOR

JERRY L. DEMINGS

COMMISSIONER

NICOLE H. WILSON

DISTRICT 1

COMMISSIONER

MAYRA URIBE

DISTRICT 3

COMMISSIONER

CHRISTINE MOORE

DISTRICT 2

COMMISSIONER

MARIBEL GOMEZ CORDERO

DISTRICT 4

COMMISSIONER

VICTORIA P. SIPLIN

DISTRICT 6

COMMISSIONER

EMILY BONILLA

DISTRICT 5

MODERNIZATION OF EXISTING ELEVATORS CONSISTING OF (19) TRACTION TYPE, AND (1) HYDRAULIC

TYPE.

ALL WORK COMPLETED UNDER THE SCOPE OF THIS PROJECT SHALL, AS A MINIMUM, COMPLY WITH THE LAWS, RULES, STANDARDS AND DECISIONS WITH THE LATEST AMENDMENTS OF THE GOVERNMENTAL

UNITS HAVING STATUTORY JURISDICTION OVER THIS PROJECT:

a. FLORIDA BUILDING CODES (2020)

b. NATIONAL ELECTRIC CODE, NFPA 70 (2017)

c. NATIONAL FIRE-ALARM CODE, NFPA 72 (2016)

d. FLORIDA FIRE PREVENTION CODE (2020)

e. LIFE SAFETY CODE, NFPA 101 (2018)

f. STATE REQUIREMENTS FOR EDUCATIONAL FACILITIES (SREF) - 2017 ED.

g. FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)

h. STANDARDS FOR ELECTRICAL PRODUCTS AND INSTALLATION

FOUND IN PUBLICATIONS BY:

- AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI),

- INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE),

- ILLUMINATING ENGINEERS SOCIETY OF NORTH AMERICA (IESNA),

- NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA),

- UNDERWRITERS LABORATORIES, INC. (UL),

- OTHERS AS APPLICABLE,

- ASHRAE,

- SMACNA,

SHEET SHEET TITLE

NUMBER

T001 COVER SHEET

A050 PLANS GROUND 5-18

A051 PLANS 19-23

A053 BUILDING B PLANS 1-5

A101 CAB PLANS

A102 CAB PLANS

A103 CAB PLANS

A104 CAB PLANS

A211 ENLARGED ELEVATIONS

A401 CAB INTERIOR ELEVATIONS

A402 CAB INTERIOR ELEVATIONS

A403 CAB INTERIOR ELEVATIONS

A404 CAB INTERIOR ELEVATIONS

E001 ELECTRICAL SYMBOLS LEGEND

E101 ELECTRICAL SITE PLAN

E301 BASEMENT LEVEL RENO PLANS

E302 LEVEL 22 RENO PLANS

E303 LEVEL 24.5 RENO PLANS

E304 BLDG A PENTHOUSE AND CEP RENO PLANS

E305 BLDG B PENTHOUSE RENO PLANS

E601 ELECTRICAL SCHEDULES

E801 ELECTRICAL DETAILS

AutoCAD SHX Text Sheet Number:

AutoCAD SHX Text Issue:

AutoCAD SHX Text Description

AutoCAD SHX Text Date

AutoCAD SHX Text No.

AutoCAD SHX Text 2014 SGM ENGINEERING, INC. DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM OR FORMAT WITHOUT PRIOR WRITTEN CONSENT OF SGM ENGINEERING, INC. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY CORRECT DIMENSIONS WITH THE ENGINEER. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.

AutoCAD SHX Text Seal:

AutoCAD SHX Text Engineer of Record:

AutoCAD SHX Text License Number:

AutoCAD SHX Text Drawn By:

AutoCAD SHX Text Checked By:

AutoCAD SHX Text 2020-119

AutoCAD SHX Text Sheet Name:

AutoCAD SHX Text Project Number:

AutoCAD SHX Text Project Name:

AutoCAD SHX Text Client Name:

AutoCAD SHX Text

1200-T001-2020331.DWG

AutoCAD SHX Text Drawing File Name:

AutoCAD SHX Text Design By:

AutoCAD SHX Text

STATE OF

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text D

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text L

AutoCAD SHX Text F

AutoCAD SHX Text No. 70700

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text P

AutoCAD SHX Text

11-08-2023 100%%% CD

AutoCAD SHX Text

JN

AutoCAD SHX Text

JN

AutoCAD SHX Text

ER

AutoCAD SHX Text

SITE MAP

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text O

AutoCAD SHX Text C

AutoCAD SHX Text Y

AutoCAD SHX Text T

AutoCAD SHX Text N

AutoCAD SHX Text U

AutoCAD SHX Text O

AutoCAD SHX Text C

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text D

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text O

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text O

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text L

AutoCAD SHX Text F

AutoCAD SHX Text Y

AutoCAD SHX Text T

AutoCAD SHX Text N

AutoCAD SHX Text D

AutoCAD SHX Text I

AutoCAD SHX Text

SCOPE OF WORK

AutoCAD SHX Text N

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

APPLICABLE CODES

AutoCAD SHX Text

BUILDING LOCATION

AutoCAD SHX Text

SHEET LIST

PUBLIC

ELEVATOR

E1

PUBLIC

ELEVATOR

E2

PUBLIC

ELEVATOR

E3

PUBLIC

ELEVATOR

E4

PUBLIC

ELEVATOR

E5

PUBLIC

ELEVATOR

E8

PUBLIC

ELEVATOR

E7

PUBLIC ELEVATOR

E6 (NO WORK)

JUDGES

ELEVATOR

J.9

JUDGES

ELEVATOR

J.12

INMATE

ELEVATOR

P.11

(NO WORK)

INMATE

ELEVATOR

E.10 (NO WORK)

A.101

A.102

A.103

A.103

EXISTING CONTEXT BEYOND

EXISTING CONTEXT

BEYOND

EXISTING CONTEXT BEYOND

NOTE:

PLANS 5-18 MAY DIFFER IN PROGRAMMATIC DESIGNATION

PER LEVEL, THIS DRAWING IS CUT AT THE GROUND LEVEL

TO INDICATE CAB LOCATION

ALL DRAWINGS GENERATED BY KMF ARCHITECTS ARE

NOT INTENDED TO BE USED FOR MANUFACTURING

PURPOSES, GENERAL ILLUSTRATION PURPOSES ONLY

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

PLANS GROUND 5

- 18

2006.20 2023.11.08

A.050 01NOTES

1/8" = 1'-0" 01BUILDING A GROUND FLOOR4'0 8' 16'

# DATE DESCRIPTION

01 2023.11.08 100%

JUDGES

ELEVATOR J9

INMATE

ELEVATOR

E10 (NO WORK)

JUDGES

ELEVATOR J12

INMATE

ELEVATOR

P11 (NO WORK)

JUDGE'S

ELEVATOR

E13

JUDGE'S

ELEVATOR

E14

PUBLIC

ELEVATOR

E1

PUBLIC

ELEVATOR

E2

PUBLIC

ELEVATOR

E3

PUBLIC

ELEVATOR

E4

PUBLIC

ELEVATOR

E5

PUBLIC ELEVATOR

E6 (NO WORK)

A.103

A.103

NOTE:

PLANS 19-23 MAY DIFFER IN PROGRAMMATIC

DESIGNATION PER LEVEL, THIS DRAWING IS CUT AT

LEVEL 19 TO INDICATE CAB LOCATION

ALL DRAWINGS GENERATED BY KMF ARCHITECTS ARE

NOT INTENDED TO BE USED FOR MANUFACTURING

PURPOSES, GENERAL ILLUSTRATION PURPOSES ONLY

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

PLANS 19 - 23

2006.20 2023.11.08

A.051 011/8" = 1'-0" 01BUILDING A LEVEL 194'0 8' 16' NOTES

PUBLIC

E19

PUBLIC

ELEVATOR

E18

ELEVATOR

LOBBY

A.104

NOTE:

PLANS 1-5 MAY DIFFER IN PROGRAMMATIC

DESIGNATION PER LEVEL, THIS DRAWING IS CUT AT THE

GROUND LEVEL TO INDICATE CAB LOCATION

ALL DRAWINGS GENERATED BY KMF ARCHITECTS ARE

NOT INTENDED TO BE USED FOR MANUFACTURING

PURPOSES, GENERAL ILLUSTRATION PURPOSES ONLY

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

BUILDING B

PLANS 1 - 5

2006.20 2023.11.08

A.053 011/8" = 1'-0" 01BUILDING B GROUND FLOOR4'0 8' 16' NOTES

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

EXISTING FLOORING TO BE RETAINED

NEW STEEL CAB WALL PANELS TO BE

INSTALLED, MATCH EXISTING

EXISTING CAB DOOR PANELS AND

HOISTWAY DOOR PANELS TO BE

RETAINED

SILLS TO BE RETAINED

NEW STEEL CAB INTERIOR CONTROL

PANEL TO BE INSTALLED, MATCH

EXISTING

NEW VENEER CEILING PANELS TO BE

INSTALLED, MATCH EXISTING

NEW MOLDING TO BE INSTALLED,

MATCH EXISTING

NEW CIRCULAR LED DOWNLIGHT TO

BE INSTALLED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING CAB SIDE WALL PANELS

TO BE REMOVED

EXISTING VENEER CAB CEILING

PANELS TO BE REMOVED WITH

MOLDING

EXISTING LED DOWNLIGHTS TO BE

REMOVED

AD.4

CAB STEEL WALL PANELS

MFR: FORM AND SURFACES

STYLE: STAINLESS STEEL CIRCLE

EMBOSSED

COLOR: TBD, MATCH EXISTING

CAB STEEL WALL BORDER PANELS

MFR: TBD

STYLE: SATIN STAINLESS STEEL

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING PANELS

MFR: TBD

STYLE: GRADE A MAHOGANY VENEER

FINISH TO MATCH EXISTING

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING

MOLDING

MFR: TBD

STYLE: MOLDING FINISHED TO MATCH

VENEER

COLOR: TBD, MATCH EXISTING

CAB CEILING LIGHTS

MFR: TBD

STYLE: CIRCULAR DOWNLIGHT, CODE

COMPLIANT

COLOR: STAINLESS STEEL/ALUMINUM

CAB BASEBOARD

MFR: TBD

STYLE: BLACK LAMINATE

COLOR: TBD, MATCH EXISTING

PUBLIC

ELEVATOR

E6 (NO WORK)

PUBLIC

ELEVATOR

E1

PUBLIC

ELEVATOR

E2

PUBLIC

ELEVATOR

E3

PUBLIC

ELEVATOR

E4

PUBLIC

ELEVATOR

E5

A.101 03-06

NOTE:

PUBLIC ELEVATORS E1 - E6 ARE SIMILAR TO

DETAILS A.101/02-05

ALL DRAWINGS GENERATED BY KMF

ARCHITECTS ARE NOT INTENDED TO BE

USED FOR MANUFACTURING PURPOSES,

GENERAL ILLUSTRATION PURPOSES ONLY

A.101 03-06

A.101 03-06

A.101 03-06

A.101 03-06

O

PE

N

IN

G

4'

0" F

.V

A.40102

PL

AT

FO

R

M W

ID

TH

6'

" F

.V

INSIDE CLEAR

5' - 2" F.V.

AD.2TYP.

AD.1TYP.

AD.3 TYP.

AD.4 TYP.

INSIDE CLEAR

5' - 2" F.V.

IN

SI

D E

C

LE

AR

6'

/2

" F .V

O

PE

N

IN

G 4'

0"

F .V

A.40106

02TYP.

05TYP.

03 TYP.

04 TYP.

PL

AT

FO

R

M W

ID

TH

6'

/2 " F

.V

A.401A.401A.401- -A.401

INSIDE CLEAR

5' - 2" F.V.

06 TYP.

07 TYP.

08 TYP.

INSIDE CLEAR

5' - 2" F.V.

IN

SI

D E

C

LE

AR

6'

/2

" F .V

EQ

EQ

EQ

EQ

EQ EQ EQ

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

CAB PLANS

2006.20 2023.11.08

A.101 010 1/2' 1' 2' NOTES

1/4" = 1'-0" 01ELEVATOR E1-E6 BLOCK ENLARGED PLAN

1" = 1'-0" 02DEMOLITION CAB PLANS E1-E5

1" = 1'-0" 03DEMOLITION REFLECTED CEILING PLAN CABS E1 - E5

1" = 1'-0" 06REFLECTED CEILING PLAN CABS E1 - E5

04CAB PLANS E1 - E6

1/4" = 1'-0"

0 2' 4' 8'0 1/2' 1' 2'

0 1/2' 1' 2'0 1/2' 1' 2'

A.102 02-05

A.102 02-05

PUBLIC

ELEVATOR

E8

PUBLIC

ELEVATOR

E7

NOTE:

PUBLIC ELEVATORS E7 - E8 ARE SIMILAR TO

DETAILS A.102/02-05

ALL DRAWINGS GENERATED BY KMF

ARCHITECTS ARE NOT INTENDED TO BE

USED FOR MANUFACTURING PURPOSES,

GENERAL ILLUSTRATION PURPOSES ONLY

O

PE

N

IN

G 3'

6"

F .V

A.402 02

INSIDE CLEAR

5' - 3" F.V.

AD.2 TYP.

AD.1 TYP.

PL

AT

FO

R

M W

ID

TH

6'

1/

8" F

.V

O

PE

N

IN

G 3'

6"

F .V

A.402 06

02 TYP.

05 TYP.

03TYP.

04TYP.

O

PE

N

IN

G 6'

1/ 8"

F .V

INSIDE CLEAR

5' - 3" F.V.

A.402A.402A.402A.402

AD.3 TYP.

AD.4 TYP.

INSIDE CLEAR

5' - 3" F.V.

IN

SI

D E

C

LE

AR

6'

1/ 8"

F .V

06 TYP.

07 TYP.

08 TYP.

INSIDE CLEAR

5' - 3" F.V.

IN

SI

D E

C

LE

AR

6'

1/ 8"

F .V

EQ EQ EQ

EQ

EQ

EQ

EQ

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

EXISTING FLOORING TO BE RETAINED

NEW STEEL CAB WALL PANELS TO BE

INSTALLED, MATCH EXISTING

EXISTING CAB DOOR PANELS AND

HOISTWAY DOOR PANELS TO BE

RETAINED

SILLS TO BE RETAINED

NEW STEEL CAB INTERIOR CONTROL

PANEL TO BE INSTALLED, MATCH

EXISTING

NEW VENEER CEILING PANELS TO BE

INSTALLED, MATCH EXISTING

NEW MOLDING TO BE INSTALLED,

MATCH EXISTING

NEW CIRCULAR LED DOWNLIGHT TO

BE INSTALLED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING CAB SIDE WALL PANELS

TO BE REMOVED

EXISTING VENEER CAB CEILING

PANELS TO BE REMOVED WITH

MOLDING

EXISTING LED DOWNLIGHTS TO BE

REMOVED

AD.4

CAB STEEL WALL PANELS

MFR: FORM AND SURFACES

STYLE: STAINLESS STEEL CIRCLE

EMBOSSED

COLOR: TBD, MATCH EXISTING

CAB STEEL WALL BORDER PANELS

MFR: TBD

STYLE: SATIN STAINLESS STEEL

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING PANELS

MFR: TBD

STYLE: GRADE A MAHOGANY VENEER

FINISH TO MATCH EXISTING

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING

MOLDING

MFR: TBD

STYLE: MOLDING FINISHED TO MATCH

VENEER

COLOR: TBD, MATCH EXISTING

CAB CEILING LIGHTS

MFR: TBD

STYLE: CIRCULAR DOWNLIGHT, CODE

COMPLIANT

COLOR: STAINLESS STEEL/ALUMINUM

CAB BASEBOARD

MFR: TBD

STYLE: BLACK LAMINATE

COLOR: TBD, MATCH EXISTING

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

CAB PLANS

2006.20 2023.11.08

A.102 011/4" = 1'-0" 01ELEVATOR E7 - E8 BLOCK ENLARGED PLAN

1" = 1'-0" 02DEMOLITION CAB PLANS E7 - E8

1" = 1'-0" 03DEMOLITION REFLECTED CEILING PLAN CABS E7 - E8

1" = 1'-0" 05REFLECTED CEILING PLAN CABS E7 - E8

NOTES04ENLARGED PLAN

1/4" = 1'-0" 04CAB PLANS E7 - E8

1/4" = 1'-0"

0 1/2' 1' 2' 0 2' 4' 8'0 1/2' 1' 2'

0 1/2' 1' 2'0 1/2' 1' 2'

JUDGES

J.12

A.103 05-08

NOTE:

PUBLIC ELEVATORS E9 - E14 SIMILAR TO

DETAILS A.103/05-08

ALL DRAWINGS GENERATED BY KMF

ARCHITECTS ARE NOT INTENDED TO BE

USED FOR MANUFACTURING

PURPOSES, GENERAL ILLUSTRATION

PURPOSES ONLY

JUDGES

ELEVATOR

J.9

A.103 05-08

NOTE:

PUBLIC ELEVATORS E9 - E14 SIMILAR

TO DETAILS A.103/05-08

ALL DRAWINGS GENERATED BY KMF

ARCHITECTS ARE NOT INTENDED TO

BE USED FOR MANUFACTURING

PURPOSES, GENERAL ILLUSTRATION

PURPOSES ONLY

JUDGE'S

ELEVATOR

E14

A.103 05-08

NOTE:

PUBLIC ELEVATORS E9 - E14 SIMILAR TO

DETAILS A.103/05-08

ALL DRAWINGS GENERATED BY KMF

ARCHITECTS ARE NOT INTENDED TO BE

USED FOR MANUFACTURING PURPOSES,

GENERAL ILLUSTRATION PURPOSES ONLY

JUDGE'S

ELEVATOR

E13

A.103 05-08

NOTE:

PUBLIC ELEVATORS E9 - E14 SIMILAR

TO DETAILS A.103/05-08

ALL DRAWINGS GENERATED BY KMF

ARCHITECTS ARE NOT INTENDED TO

BE USED FOR MANUFACTURING

PURPOSES, GENERAL ILLUSTRATION

PURPOSES ONLY

A.403

0204 A.403A.403A.403A.403A.403

PLATFORM WIDTH

6' - 8 1/8" F.V.

OPENING

3' - 6" F.V.

AD.2TYP.

AD.1TYP.

IN

SI

D E

C

LE

AR

4'

8"

F .V

A.403A.403A.403A.403 06A.40308 A.403A.403

A.403

INSIDE CLEAR

3' - 6" F.V.

PLATFORM WIDTH

6' - 8" F.V.

IN

SI

D E

C

LE

AR

4'

8"

F .V

02TYP.

05TYP.

03 TYP.

04 TYP.

A.403A.403A.403-

IN

SI

D E

C

LE

AR

4'

8"

F .V

INSIDE CLEAR

6' - 8 1/8" F.V.

EQ

EQ

EQ

06 TYP.

07 TYP.

08 TYP.

EQ EQ EQ EQ

INSIDE CLEAR

6' - 8 1/8" F.V.

IN

SI

D E

C

LE

AR

4'

8"

F .V

AD.3TYP.

AD.4TYP.

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

EXISTING FLOORING TO BE RETAINED

NEW STEEL CAB WALL PANELS TO BE

INSTALLED, MATCH EXISTING

EXISTING CAB DOOR PANELS AND

HOISTWAY DOOR PANELS TO BE

RETAINED

SILLS TO BE RETAINED

NEW STEEL CAB INTERIOR CONTROL

PANEL TO BE INSTALLED, MATCH

EXISTING

NEW VENEER CEILING PANELS TO BE

INSTALLED, MATCH EXISTING

NEW MOLDING TO BE INSTALLED,

MATCH EXISTING

NEW CIRCULAR LED DOWNLIGHT TO

BE INSTALLED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING CAB SIDE WALL PANELS

TO BE REMOVED

EXISTING VENEER CAB CEILING

PANELS TO BE REMOVED WITH

MOLDING

EXISTING LED DOWNLIGHTS TO BE

REMOVED

AD.4

CAB STEEL WALL PANELS

MFR: FORM AND SURFACES

STYLE: STAINLESS STEEL CIRCLE

EMBOSSED

COLOR: TBD, MATCH EXISTING

CAB STEEL WALL BORDER PANELS

MFR: TBD

STYLE: SATIN STAINLESS STEEL

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING PANELS

MFR: TBD

STYLE: GRADE A MAHOGANY VENEER

FINISH TO MATCH EXISTING

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING

MOLDING

MFR: TBD

STYLE: MOLDING FINISHED TO MATCH

VENEER

COLOR: TBD, MATCH EXISTING

CAB CEILING LIGHTS

MFR: TBD

STYLE: CIRCULAR DOWNLIGHT, CODE

COMPLIANT

COLOR: STAINLESS STEEL/ALUMINUM

CAB BASEBOARD

MFR: TBD

STYLE: BLACK LAMINATE

COLOR: TBD, MATCH EXISTING

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

CAB PLANS

2006.20 2023.11.08

A.103 01

1/4" = 1'-0" 02ELEVATOR E12 ENLARGED PLAN

1/4" = 1'-0" 01ELEVATOR E9 ENLARGED PLAN

1/4" = 1'-0" 04ELEVATOR E14 ENLARGED PLAN

1/4" = 1'-0" 03ELEVATOR E13 ENLARGED PLAN

1" = 1'-0" 05DEMOLITION CAB PLANS E9 - E14

1" = 1'-0" 08REFLECTED CEILING PLAN CABS E9 - E14

1" = 1'-0" 06DEMOLITION REFLECTED CEILING PLAN CABS E9 - E14

0 1/2' 1' 2' 0 2' 4' 8'

0 2' 4' 8'

0 1/2' 1' 2'

0 1/2' 1' 2'0 1/2' 1' 2'

0 2' 4' 8'

0 2' 4' 8'

07CAB PLAN E9 - E14

1/4" = 1'-0"

NOTES

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

EXISTING FLOORING TO BE RETAINED

NEW STEEL CAB WALL PANELS TO BE

INSTALLED, MATCH EXISTING

EXISTING CAB DOOR PANELS AND

HOISTWAY DOOR PANELS TO BE

RETAINED

SILLS TO BE RETAINED

NEW STEEL CAB INTERIOR CONTROL

PANEL TO BE INSTALLED, MATCH

EXISTING

NEW VENEER CEILING PANELS TO BE

INSTALLED, MATCH EXISTING

NEW MOLDING TO BE INSTALLED,

MATCH EXISTING

NEW CIRCULAR LED DOWNLIGHT TO

BE INSTALLED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING CAB SIDE WALL PANELS

TO BE REMOVED

EXISTING VENEER CAB CEILING

PANELS TO BE REMOVED WITH

MOLDING

EXISTING LED DOWNLIGHTS TO BE

REMOVED

AD.4

CAB STEEL WALL PANELS

MFR: FORM AND SURFACES

STYLE: STAINLESS STEEL CIRCLE

EMBOSSED

COLOR: TBD, MATCH EXISTING

CAB STEEL WALL BORDER PANELS

MFR: TBD

STYLE: SATIN STAINLESS STEEL

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING PANELS

MFR: TBD

STYLE: GRADE A MAHOGANY VENEER

FINISH TO MATCH EXISTING

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING

MOLDING

MFR: TBD

STYLE: MOLDING FINISHED TO MATCH

VENEER

COLOR: TBD, MATCH EXISTING

CAB CEILING LIGHTS

MFR: TBD

STYLE: CIRCULAR DOWNLIGHT, CODE

COMPLIANT

COLOR: STAINLESS STEEL/ALUMINUM

CAB BASEBOARD

MFR: TBD

STYLE: BLACK LAMINATE

COLOR: TBD, MATCH EXISTING

PROSECUTOR

ELEVATOR

E19

PROSECUTOR

ELEVATOR

E18

A.104

A.104 03-06

A.101 03-06

NOTE:

PUBLIC ELEVATORS E18 - E19 SIMILAR TO DETAILS

A.104/03-06

ALL DRAWINGS GENERATED BY KMF ARCHITECTS

ARE NOT INTENDED TO BE USED FOR

MANUFACTURING PURPOSES, GENERAL

ILLUSTRATION PURPOSES ONLY

A.404 02

A.404A.404A.404A.404

AD.2TYP.

AD.1TYP.

INSIDE CLEAR

5' - 0" F.V.

O

PE

N

IN

G 3'

6"

F .V

PL

AT

FO

R

M W

ID

TH

6'

" F

.V

A.404A.404A.404A.404A.404

A.40408 A.404

A.404 06

02TYP.

05TYP.

03 TYP.

04 TYP.

INSIDE CLEAR

5' - 0" F.V.

O

PE

N

IN

G 3'

6"

F .V

PL

AT

FO

R

M W

ID

TH

6'

" F

.V

A.404A.404A.404A.404

EQ EQ EQ

INSIDE CLEAR

5' - 0" F.V.

EQ

EQ

EQ

EQ

IN

SI

D E

C

LE

AR

6'

" F .V

06 TYP.

07 TYP.

08 TYP.

IN

SI

D E

C

LE

AR

6'

" F .V

06 TYP.

07 TYP.

08 TYP.

INSIDE CLEAR

5' - 0" F.V.

A.101 03-06

A.101 03-06

DEFENDER

ELEVATOR

E16

DEFENDER

ELEVATOR

E17

NOTE:

PUBLIC ELEVATORS E16 - E17 SIMILAR TO DETAILS

A.104/03-06

CABS E16 & E17 ARE LOCATED IN BUILDING A LEVEL

ONE

ALL DRAWINGS GENERATED BY KMF ARCHITECTS

ARE NOT INTENDED TO BE USED FOR

MANUFACTURING PURPOSES, GENERAL

ILLUSTRATION PURPOSES ONLY

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

CAB PLANS

2006.20 2023.11.08

A.104 011/4" = 1'-0" 01ELEVATOR E18 - E19 BLOCK ENLARGED PLAN

1" = 1'-0" 03DEMOLITION CAB PLANS E16 - E19 NOTES0 1/2' 1' 2' 0 1/2' 1' 2'

0 1/2' 1' 2'0 1/2' 1' 2'

0 2' 4' 8'

1" = 1'-0" 04DEMOLITION REFLECTED CEILING PLAN CABS E16 - E19

05CAB PLANS E16 - E19

1/4" = 1'-0"

06REFLECTED CEILING PLAN CABS E16 - E19

1/4" = 1'-0" 1/4" = 1'-0" 02ELEVATOR E16- E170 2' 4' 8'

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING AND CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS.

EXPOSED ITEMS MUST BE LOCATED IN .

ALL EXPOSED ITEMS ARE TO BE

PAINTED TO MATCH THE ADJACENT

SURFACES UNLESS SCHEDULED FOR AN

ACCENT COLOR.

KEY NOTES

1 EXISTING FLOORING TO REMAIN

NEW STAINLESS STEEL SIDE WALL

PANELS TO BE INSTALLED

NEW INTERIOR CAB DOOR PANELS

TO BE INSTALLED (FINISH TBD)

EXISTING SILLS TO REMAIN

NEW STAINLESS STEEL CAB

INTERIOR CONTROL PANEL TO BE

INSTALLED

NEW RECESSED WALL REVEAL TO

BE INSTALLED (FINISH TBD)

NEW STAINLESS STEEL DOWNLIGHT

CEILING PANELS TO BE INSTALLED

NEW SQUARE LED LIGHT FIXTURE

NEW RECESSED CEILING REVEAL

PANEL TO BE INSTALLED (FINISH

TBD)

PUBLIC ELEVATORS E6 AND E7

SIMILAR TO E1, E2, E3, E4, AND E5

F.

V.

CL

2' - 9 1/4"

NEW DOOR

PANELS

NEW INDICATOR

BUTTON

NEW STAINLESS

STEEL PANEL

NEW BUTTON

ARRAY SYSTEM

3' - 9"

5" 2'

5"

2"

5'

2'

F.

V.

NEW WALL

REVEAL PANEL

NEW STAINLESS STEEL

WALL PANELS

NEW STAINLESS STEEL

GUARD RAIL

5' - 2 5/8"

NEW WALL

REVEAL PANEL

NEW STAINLESS STEEL

WALL PANELS

NEW STAINLESS STEEL

GUARD RAIL

NEW STAINLESS STEEL

PANEL (SIDE OF

CONTROL PANEL)

F.

V.

5'

2" 2'

5"

5"

2'

F.

V.

NEW WALL

REVEAL PANEL

NEW STAINLESS STEEL

WALL PANELS

NEW STAINLESS STEEL

GUARD RAIL

5" 2'

5"

2" 5'

" F .V

2'

F.

V.

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

ENLARGED

ELEVATIONS

2006.20 2023.11.08

A.211 01NOTES

1" = 1'-0" 01WEST INTERIOR ELEVATION

1" = 1'-0" 02EAST INTERIOR ELEVATION

1" = 1'-0" 03NORTH INTERIOR ELEVATION

1" = 1'-0" 04SOUTH INTERIOR ELEVATION

0 1/2' 1' 2'

0 1/2' 1' 2'0 1/2' 1' 2'

0 1/2' 1' 2'

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

EXISTING FLOORING TO BE RETAINED

NEW STEEL CAB WALL PANELS TO BE

INSTALLED, MATCH EXISTING

EXISTING CAB DOOR PANELS AND

HOISTWAY DOOR PANELS TO BE

RETAINED

SILLS TO BE RETAINED

NEW STEEL CAB INTERIOR CONTROL

PANEL TO BE INSTALLED, MATCH

EXISTING

NEW VENEER CEILING PANELS TO BE

INSTALLED, MATCH EXISTING

NEW MOLDING TO BE INSTALLED,

MATCH EXISTING

NEW CIRCULAR LED DOWNLIGHT TO

BE INSTALLED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING CAB SIDE WALL PANELS

TO BE REMOVED

EXISTING VENEER CAB CEILING

PANELS TO BE REMOVED WITH

MOLDING

EXISTING LED DOWNLIGHTS TO BE

REMOVED

AD.4

CAB STEEL WALL PANELS

MFR: FORM AND SURFACES

STYLE: STAINLESS STEEL CIRCLE

EMBOSSED

COLOR: TBD, MATCH EXISTING

CAB STEEL WALL BORDER PANELS

MFR: TBD

STYLE: SATIN STAINLESS STEEL

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING PANELS

MFR: TBD

STYLE: GRADE A MAHOGANY VENEER

FINISH TO MATCH EXISTING

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING

MOLDING

MFR: TBD

STYLE: MOLDING FINISHED TO MATCH

VENEER

COLOR: TBD, MATCH EXISTING

CAB CEILING LIGHTS

MFR: TBD

STYLE: CIRCULAR DOWNLIGHT, CODE

COMPLIANT

COLOR: STAINLESS STEEL/ALUMINUM

CAB BASEBOARD

MFR: TBD

STYLE: BLACK LAMINATE

COLOR: TBD, MATCH EXISTING

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE EXISTING

HANDRAIL

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE STEEL WALL

PANELS, TYP.

REMOVE INDICATOR BUTTON,

TYP.

REMOVE BUTTON ARRAY

SYSTEM

NEW WOOD VENEER WALL

PANELS TO MATCH EXISTING,

TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

EQ EQ EQ

5' - 2" F.V.

9'

0" F

.V

NEW STEEL SIDE CONTROL

PANEL, MATCH EXISTING

NEW WOOD VENEER WALL

PANELS TO MATCH EXISTING,

TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

EQ EQ EQ EQ

6' - 11 1/2" F.V.

9'

0" F

.V

NEW STEEL HANDRAIL TO MATCH

EXISTING, TYP.

NEW WOOD VENEER WALL

PANELS TO MATCH EXISTING,

TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

EQ EQ EQ

5' - 2" F.V.

9'

0" F

.V

NEW STEEL SIDE CONTROL

PANEL, MATCH EXISTING

NEW BUTTON ARRAY

SYSTEM, MATCH EXISTING

NEW STEEL CONTROL PANEL,

MATCH EXISTING

NEW INDICATOR BUTTON,

MATCH EXISTING

EQ 4' - 0" F.V. EQ

6' - 11 1/2" F.V.

9'

0" F

.V

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

CAB INTERIOR

ELEVATIONS

2006.20 2023.11.08

A.401 011/2" = 1'-0" 01INTERIOR NORTH DEMO ELEVATION CABS E1-E5

1/2" = 1'-0" 02INTERIOR WEST DEMO ELEVATION CABS E1-E5

1/2" = 1'-0" 03INTERIOR SOUTH DEMO ELEVATION CABS E1- E5

1/2" = 1'-0" 04INTERIOR EAST DEMO ELEVATION CABS E1 - E5

1/2" = 1'-0" 05INTERIOR NORTH ELEVATION CABS E1 - E5

1/2" = 1'-0" 06INTERIOR WEST ELEVATION CABS E1 - E5

1/2" = 1'-0" 07INTERIOR SOUTH ELEVATION CABS E1 - E5

1/2" = 1'-0" 08INTERIOR EAST ELEVATION CABS E1 - E5

1/2" = 1'-0" 09INTERIOR FINISHES NORTH ELEVATION CABS E1 - E5

1/2" = 1'-0" 10INTERIOR FINISHES WEST ELEVATION CABS E1 - E5

1/2" = 1'-0" 11INTERIOR FINISHES SOUTH ELEVATION CABS E1 - E5

1/2" = 1'-0" 12INTERIOR FINISHES EAST ELEVATION CABS E1 - E5

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

NOTES

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE EXISTING HANDRAIL

REMOVE STEEL WALL

PANELS, TYP.

REMOVE INDICATOR BUTTON,

TYP.

REMOVE BUTTON ARRAY

SYSTEM

NEW WOOD VENEER WALL

PANELS TO MATCH EXISTING,

TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

EQ EQ EQ

5' - 3" F.V.

NEW STEEL SIDE CONTROL

PANEL TO MATCH EXISTING

7'

3/

8" F

.V

NEW WOOD VENEER WALL

PANELS TO MATCH EXISTING,

TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH EXISTING,

TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING, TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

EQ EQ EQ EQ

7'

5/

8" F

.V

6' - 8 1/8" F.V.

NEW STEEL HANDRAIL TO MATCH

EXISTING, TYP.

NEW WOOD VENEER WALL

PANELS TO MATCH EXISTING, TYP.

NEW WOOD VENEER MOLDINGS TO

MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

NEW STEEL SIDE CONTROL

PANEL TO MATCH EXISTING

EQ EQ EQ

5' - 3" F.V.

7'

3/

8" F

.V

NEW INDICATOR BUTTON

NEW BUTTON ARRAY

SYSTEM

NEW STAINLESS

STEEL CONTROL

PANEL

7'

3/

8" F

.V

EQ 3' - 6" F.V. EQ

6' - 8 1/8" F.V.

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

EXISTING FLOORING TO BE RETAINED

NEW STEEL CAB WALL PANELS TO BE

INSTALLED, MATCH EXISTING

EXISTING CAB DOOR PANELS AND

HOISTWAY DOOR PANELS TO BE

RETAINED

SILLS TO BE RETAINED

NEW STEEL CAB INTERIOR CONTROL

PANEL TO BE INSTALLED, MATCH

EXISTING

NEW VENEER CEILING PANELS TO BE

INSTALLED, MATCH EXISTING

NEW MOLDING TO BE INSTALLED,

MATCH EXISTING

NEW CIRCULAR LED DOWNLIGHT TO

BE INSTALLED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING CAB SIDE WALL PANELS

TO BE REMOVED

EXISTING VENEER CAB CEILING

PANELS TO BE REMOVED WITH

MOLDING

EXISTING LED DOWNLIGHTS TO BE

REMOVED

AD.4

CAB STEEL WALL PANELS

MFR: FORM AND SURFACES

STYLE: STAINLESS STEEL CIRCLE

EMBOSSED

COLOR: TBD, MATCH EXISTING

CAB STEEL WALL BORDER PANELS

MFR: TBD

STYLE: SATIN STAINLESS STEEL

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING PANELS

MFR: TBD

STYLE: GRADE A MAHOGANY VENEER

FINISH TO MATCH EXISTING

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING

MOLDING

MFR: TBD

STYLE: MOLDING FINISHED TO MATCH

VENEER

COLOR: TBD, MATCH EXISTING

CAB CEILING LIGHTS

MFR: TBD

STYLE: CIRCULAR DOWNLIGHT, CODE

COMPLIANT

COLOR: STAINLESS STEEL/ALUMINUM

CAB BASEBOARD

MFR: TBD

STYLE: BLACK LAMINATE

COLOR: TBD, MATCH EXISTING

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

CAB INTERIOR

ELEVATIONS

2006.20 2023.11.08

A.402 011/2" = 1'-0" 01INTERIOR NORTH DEMO ELEVATION CABS E7 - E8

1/2" = 1'-0" 03INTERIOR SOUTH DEMO ELEVATION CABS E7 - E8

1/2" = 1'-0" 02INTERIOR EAST DEMO ELEVATION CABS E7 - E8

1/2" = 1'-0" 04INTERIOR WEST DEMO ELEVATION CABS E7 - E8

1/2" = 1'-0" 05INTERIOR NORTH ELEVATION CABS E7 - E8

1/2" = 1'-0" 06INTERIOR EAST ELEVATIONS CABS E7 - E8

1/2" = 1'-0" 07INTERIOR SOUTH ELEVATIONS CABS E7 - E8

1/2" = 1'-0" 08INTERIOR WEST ELEVATIONS CABS E7 - E8

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

1/2" = 1'-0" 09INTERIOR FINISHES NORTH ELEVATION CABS E7 - E8

1/2" = 1'-0" 10INTERIOR FINISHES EAST ELEVATIONS CABS E7 - E8

1/2" = 1'-0" 11INTERIOR FINISHES SOUTH ELEVATIONS CABS E7 - E8

1/2" = 1'-0" 12INTERIOR FINISHES WEST ELEVATION CABS E7 - E8

NOTES

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE EXISTING

HANDRAIL

REMOVE STEEL WALL

PANELS, TYP.

REMOVE INDICATOR BUTTON,

TYP.

REMOVE BUTTON ARRAY

SYSTEM

NEW WOOD VENEER WALL PANELS

TO MATCH EXISTING, TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

NEW STEEL SIDE CONTROL

PANEL TO MATCH EXISTING

4' - 8" F.V.

EQ EQ EQ

7'

6" F

.V

NEW WOOD VENEER WALL PANELS

TO MATCH EXISTING, TYP.

NEW WOOD VENEER MOLDINGS TO

MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL WALL

PANELS TO MATCH EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING, TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

NEW STEEL SIDE CONTROL

PANEL TO MATCH EXISTING

EQ EQ EQ

4' - 8" F.V.

7'

6" F

.V

NEW WOOD VENEER WALL

PANELS TO MATCH EXISTING, TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH EXISTING,

TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

EQ EQ EQ EQ

6' - 8 1/8" F.V.

7'

6" F

.V

NEW STEEL HANDRAIL TO MATCH

EXISTING, TYP.

NEW INDICATOR BUTTON

NEW BUTTON ARRAY

SYSTEM

NEW STAINLESS

STEEL CONTROL

PANEL

EQ3' - 6" F.V.EQ

6' - 8 1/8" F.V.

7'

6" F

.V

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

EXISTING FLOORING TO BE RETAINED

NEW STEEL CAB WALL PANELS TO BE

INSTALLED, MATCH EXISTING

EXISTING CAB DOOR PANELS AND

HOISTWAY DOOR PANELS TO BE

RETAINED

SILLS TO BE RETAINED

NEW STEEL CAB INTERIOR CONTROL

PANEL TO BE INSTALLED, MATCH

EXISTING

NEW VENEER CEILING PANELS TO BE

INSTALLED, MATCH EXISTING

NEW MOLDING TO BE INSTALLED,

MATCH EXISTING

NEW CIRCULAR LED DOWNLIGHT TO

BE INSTALLED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING CAB SIDE WALL PANELS

TO BE REMOVED

EXISTING VENEER CAB CEILING

PANELS TO BE REMOVED WITH

MOLDING

EXISTING LED DOWNLIGHTS TO BE

REMOVED

AD.4

CAB STEEL WALL PANELS

MFR: FORM AND SURFACES

STYLE: STAINLESS STEEL CIRCLE

EMBOSSED

COLOR: TBD, MATCH EXISTING

CAB STEEL WALL BORDER PANELS

MFR: TBD

STYLE: SATIN STAINLESS STEEL

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING PANELS

MFR: TBD

STYLE: GRADE A MAHOGANY VENEER

FINISH TO MATCH EXISTING

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING

MOLDING

MFR: TBD

STYLE: MOLDING FINISHED TO MATCH

VENEER

COLOR: TBD, MATCH EXISTING

CAB CEILING LIGHTS

MFR: TBD

STYLE: CIRCULAR DOWNLIGHT, CODE

COMPLIANT

COLOR: STAINLESS STEEL/ALUMINUM

CAB BASEBOARD

MFR: TBD

STYLE: BLACK LAMINATE

COLOR: TBD, MATCH EXISTING

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U R

TH

O

U

SE

N . O

R

AN

G E

AV

E.

O R

LA

N

D O

, F L

PA

SS

EN

G

ER

E

LE

VA

TO

R

IN

TE

R

IO

R

R

EM

O D

EL

CAB INTERIOR

ELEVATIONS

2006.20 2023.11.08

A.403 01

1/2" = 1'-0" 02INTERIOR EAST DEMO ELEVATION CABS E9 - E14

1/2" = 1'-0" 04INTERIOR WEST DEMO ELEVATION CABS E9 - E14

1/2" = 1'-0" 03INTERIOR SOUTH DEMO ELEVATION CABS E9 - E14

1/2" = 1'-0" 01INTERIOR NORTH DEMO ELEVATION CABS E9 - E14

1/2" = 1'-0" 06INTERIOR EAST ELEVATION CABS E9 - E14

1/2" = 1'-0" 08INTERIOR WEST ELEVATION CABS E9 - E14

1/2" = 1'-0" 07INTERIOR SOUTH ELEVATION CABS E9 - E14

1/2" = 1'-0" 05INTERIOR NORTH ELEVATION CABS E9 - E14 0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

1/2" = 1'-0" 09INTERIOR FINISHES NORTH ELEVATION CABS E9 - E14

1/2" = 1'-0" 10INTERIOR FINISHES EAST ELEVATION CABS E9 - E14

1/2" = 1'-0" 11INTERIOR FINISHES SOUTH ELEVATION CABS E9 - E14

1/2" = 1'-0" 12INTERIOR FINISHES WEST ELEVATION CABS E9 - E14

NOTES

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS

EXPOSED ITEMS ARE TO BE PAINTED TO

MATCH THE ADJACENT SURFACES

UNLESS SCHEDULED FOR AN ACCENT

COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

EXISTING FLOORING TO BE RETAINED

NEW STEEL CAB WALL PANELS TO BE

INSTALLED, MATCH EXISTING

EXISTING CAB DOOR PANELS AND

HOISTWAY DOOR PANELS TO BE

RETAINED

SILLS TO BE RETAINED

NEW STEEL CAB INTERIOR CONTROL

PANEL TO BE INSTALLED, MATCH

EXISTING

NEW VENEER CEILING PANELS TO BE

INSTALLED, MATCH EXISTING

NEW MOLDING TO BE INSTALLED,

MATCH EXISTING

NEW CIRCULAR LED DOWNLIGHT TO

BE INSTALLED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING CAB SIDE WALL PANELS

TO BE REMOVED

EXISTING VENEER CAB CEILING

PANELS TO BE REMOVED WITH

MOLDING

EXISTING LED DOWNLIGHTS TO BE

REMOVED

AD.4

CAB STEEL WALL PANELS

MFR: FORM AND SURFACES

STYLE: STAINLESS STEEL CIRCLE

EMBOSSED

COLOR: TBD, MATCH EXISTING

CAB STEEL WALL BORDER PANELS

MFR: TBD

STYLE: SATIN STAINLESS STEEL

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING PANELS

MFR: TBD

STYLE: GRADE A MAHOGANY VENEER

FINISH TO MATCH EXISTING

COLOR: TBD, MATCH EXISTING

CAB VENEER WALL + CEILING

MOLDING

MFR: TBD

STYLE: MOLDING FINISHED TO MATCH

VENEER

COLOR: TBD, MATCH EXISTING

CAB CEILING LIGHTS

MFR: TBD

STYLE: CIRCULAR DOWNLIGHT, CODE

COMPLIANT

COLOR: STAINLESS STEEL/ALUMINUM

CAB BASEBOARD

MFR: TBD

STYLE: BLACK LAMINATE

COLOR: TBD, MATCH EXISTING

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE EXISTING HANDRAIL

REMOVE STEEL WALL

PANELS, TYP.

REMOVE VENEER WALL

PANELS AND MOLDINGS, TYP.

REMOVE BASEBOARD

REMOVE STEEL WALL

PANELS, TYP.

REMOVE INDICATOR BUTTON,

TYP.

REMOVE BUTTON ARRAY

SYSTEM

NEW WOOD VENEER WALL PANELS

TO MATCH EXISTING, TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

EQ EQ EQ

4' - 11" F.V.

8'

1/

2" F

.V

NEW WOOD VENEER WALL PANELS

TO MATCH EXISTING, TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

EQ EQ EQ EQ

6' - 11" F.V.

8'

1/

2" F

.V

NEW STEEL HANDRAIL TO MATCH

EXISTING, TYP.

EQ EQ EQ

5' - 0" F.V.

NEW WOOD VENEER WALL PANELS

TO MATCH EXISTING, TYP.

NEW WOOD VENEER MOLDINGS

TO MATCH EXISTING, TYP.

NEW CIRCLE EMBOSSED STEEL

WALL PANELS TO MATCH

EXISTING, TYP.

NEW SATIN STAINLESS BORDER

PANELS TO MATCH EXISTING,

TYP.

NEW BLACK LAMINATE

BASEBOARD TO MATCH EXISTING,

TYP.

8'

1/

2" F

.V

EQ 3' - 6" F.V. EQ

6' - 11" F.V.

8'

1/

2" F

.V

NEW INDICATOR BUTTON

NEW BUTTON ARRAY

SYSTEM

NEW STAINLESS

STEEL CONTROL

PANEL

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O R

AN

G

E C

O U

N

TY

C O

U…

This is the start of the file's text. The full file is on GovTribe.