Text version
BRINCKERHOFF
PARSONS
SRL
NO.
SHEET
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:17:02 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\Wall_Index_Of_Sheets.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
INDEX OF STRUCTURES PLANS
W-1
INDEX OF SHEETS
SHEET NO. SHEET DESCRIPTION
W-17
W-16
W-15
W-14
W-13
W-12
W-11
W-10
W-9
W-8
W-7
W-6
W-5
W-4
W-3
W-2
W-1
WALL PIPE PENETRATION DETAILS
WALL COPING DETAILS (2 OF 2)
WALL COPING DETAILS (1 OF 2)
STAIR TYPICAL SECTION
WALL TYPICAL SECTION
CONSTRUCTION SEQUENCE
WALL GEOMETRY
WALL PROFILE (4 OF 4)
WALL PROFILE (3 OF 4)
WALL PROFILE (2 OF 4)
WALL PROFILE (1 OF 4)
WALL PLAN (4 OF 4)
WALL PLAN (3 OF 4)
WALL PLAN (2 OF 4)
WALL PLAN (1 OF 4)
GENERAL NOTES
INDEX OF SHEETS
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:22:07 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallGeneralNotes01.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
W-2
GENERAL NOTES
Location
CrestWave
PressureDynamic
TroughWave
PressureDynamic Scour
Wall ofTop Mudline
Wave ofTop Mudline nElevatio
Mudline
Depth
Scour nElevatio
Scour
(lb/Ft )
(lb/Ft (Ft) )
(lb/Ft
MLLW)
(Ft, (Ft)
MLLW)
(Ft, 239+90Sta. 703 682 -1.4 102 -3.0 5.5 -8.5
240+20Sta. 703 682 -1.6 119 -3.5 5.6 -9.1
240+70Sta. 703 682 -1.4 102 -3.0 5.5 -8.5
243+30Sta. 703 682 -1.4 102 -3.0 3.8 -6.8
244+40Sta. 703 682 -1.9 136 -4.0 3.9 -7.9
246+00Sta. 852 822 -2.3 170 -5.0 4.7 -9.7
246+50Sta. 852 822 -2.8 204 -6.0 4.5 -10.5
247+00Sta. 738 717 -1.9 136 -4.0 6.4 -10.4
249+00Sta. 852 822 -2.1 153 -4.5 6.4 -10.9
251+00Sta. 852 822 -2.1 153 -4.5 7.9 -12.4
252+00Sta. 831 803 -1.9 136 -4.0 5.7 -9.7
252+80Sta. 831 803 -2.3 170 -5.0 7.6 -12.6
254+50Sta. 831 803 -2.3 170 -5.0 5.7 -10.7
255+80Sta. 1055 1008 -4.2 306 -9.0 3.0 -12.0
257+10Sta. 1001 959 -3.7 272 -8.0 6.0 -14.0
258+10Sta. 1001 959 -3.7 272 -8.0 6.0 -14.0
258+80Sta. 1001 959 -3.7 272 -8.0 7.5 -15.5
WATER LEVEL ON THE RETAINED SIDE OF WALL IS EQUAL TO THE WALL HEIGHT.
ABOVE FOR THE STATIC PRESSURE ON FRONT SIDE OF WALL. ASSUME THE
ASSUME THE DYNAMIC WAVE TROUGH ELEVATION AND PRESSURE SHOWN
WAVE TROUGHB.
RETAINED SIDE OF WALL SHALL BE ASSUMED TO BE EQUAL.
IS EQUAL TO THE WALL HEIGHT. STATIC PRESSURE ON FRONT AND
ASSUME THE WATER LEVEL ON THE FRONT AND RETAINED SIDE OF WALL
WAVE CRESTA.
EXTREME HYDRULIC EVENTS:
64 pcfSTATIC PRESSURE
HYDRAULIC LOADS:6.
SEISMIC PERFORMANCE ZONE 4
= 0.73 D1
S= 0.24
S
= 0.91
DS
S= 0.80 S
S
= 0.37 S
A= 0.37PGA
SITE EFFECTSDESIGN ACCELERATION
SEISMIC LOADING:5.
LIVE LOAD SURCHARGE: 250 psf
SUPPORTING CONSTRUCTION LOADS THAT EXCEED AASHTO HL-93.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE FOR
b. TROLLEY (ASSUMED) 4 AXLE: 9400 lb/AXLE
a. HL-93 LIVE LOADING
LIVE LOADS:4.
REINFORCED CONCRETE (COPING): 150 pcf
UNREINFORCED CONCRETE (QUAY WALL BLOCKS): 140 pcf
DEAD LOADS:3.
(AASHTO) LRFD BRIDGE DESIGN SPECIFICATIONS (6TH EDITION)
AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION
DESIGN SPECIFICATIONS:2.
PROJECTS (FP-03)
FOR CONSTRUCTION OF ROADS AND BRIDGES ON FEDERAL HIGHWAY
FEDERAL HIGHWAY ADMINISTRATION STANDARD SPECIFICATIONS
GENERAL SPECIFICATIONS:1.
WILL REQUIRE DIVERS.
LIMITED TO: EXCAVATION, BASE LEVELING PAD, AND BLOCK PLACEMENT,
IT IS ANTICIPATED WALL CONSTRUCTION WORK, INCLUDING BUT NOT
UNDERWATER CONSTRUCTION:4.
MAY BE ENCOUNTERED DURING EXCAVATION AND WALL INSTALLATION.
FOR GEOTECHNICAL INFORMATION. DENSE TO VERY DENSE LAYERS
SEE REPORT OF CORE BORING SHEETS AND GEOTECHNICAL REPORT
GEOTECHNICAL:3.
DISPOSED OF IN ACCORDANCE WITH SPECIFICATIONS SECTION 203.05.
RIP RAP THAT DOES NOT MEET WITH THE CO'S APPROVAL SHALL BE
THE CONTRACT DRAWINGS AT NO ADDITIONAL COST TO THE GOVERNMENT.
EXISTING WALL MAY BE REUSED IN FRONT OF THE WALL AS SHOWN IN
UPON APPROVAL OF THE CO RIP RAP AND BOULDERS REMOVED ALONG THE
EXISTING RIP RAP REMOVAL:2.
EMAIL: MICHAEL.B.LIEBERUM@USCG.MIL
PHONE NO. 305-415-6744, FAX NO. 305-415-6763
MIAMI, FL 33131-3028
909 SE FIRST AVENUE
SEVENTH COAST GUARD DISTRICT
CHIEF, BRIDGE OPERATIONS SECTIONS
COMMANDER (DPB)
THE CONTACT FOR THE UNITED STATES COAST GUARD IS:1.
MISCELLANEOUS NOTES:
EL. 0.00MLLW
EL. 0.06MLW
EL. 0.77MHW
EL. 0.82MHHW
AND TIDAL EPOCH.
ALL ELEVATIONS REFER TO MLLW WITH REFERENCE TO TIDE STATION
VERTICAL DATUM:13.
SECTION 552.14.C.3
COPING: TROWELED AND BRUSHED FINISH PER SPECIFICATION
SIMILARLY MATCH:
FINISH PRIOR TO CONSTRUCTION OF BLOCKS. SURFACE TO
QUAY WALL: CONTRACTOR TO SUBMIT SAMPLE OF PROPOSED SURFACE
THE WALL SHOP DRAWINGS.
OF STANDARD COLORS FOR SELECTION BY THE OWNER AS PART OF
THE CONTRACTOR SHALL PROVIDE A SAMPLEINTEGRAL PIGMENT.
COLOR: CONCRETE (WALL AND COPING) SHALL BE COLORED UTILIZING AN
CONCRETE SURFACE FINISH:12.
INFORMATION, REFER TO THE UTILITY AND LIGHTING PLANS.
LOCATION. NOT ALL UTILITIES ARE SHOWN. FOR ADDITIONAL
THE UTILITIES SHOWN IN THESE WALL PLANS ARE APPROXIMATE IN
UTILITIES:11.
THOSE SHOWN SHALL REQUIRE APPROVAL OF THE CO.
ON THE PLANS. ADDITIONAL CONSTRUCTION JOINTS OR ALTERNATIONS TO
CONSTRUCTION JOINTS WILL BE PERMITTED ONLY AT LOCATIONS INDICATED
JOINTS IN CONCRETE:10.
STEEL: EXTREMELY AGGRESSIVE
CONCRETE: EXTREMELY AGGRESSIVE
ENVIRONMENTAL CLASSIFICATION:9.
CONCRETE COVER SHALL BE 3 IN. CLEAR FOR ALL FACES U.O.N.
ALL REINFORCING STEEL SHALL BE STAINLESS STEEL ASTM A955, GRADE 60.
REINFORCING STEEL:8.
COPINGf'c = 5.5A(E)
QUAY WALL BLOCKSf'c = 4.0A(E)
STRUCTURESTRENGTH (ksi)
CONCRETE INCOMPRESSIVECLASS
LOCATION OFMIN. 28-DAYCONCRETE
ALL CONCRETE SHALL BE IN ACCORDANCE WITH SPECIFICATION 552.
CONCRETE:7.
241 242
241 242
P O
T
S
T A
.3
P C
S
T A
.1
P T
S
T A
.2
P C
S
T A
.5
DESIGNED
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:26:36 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallControl01.DGNLawsonS
VETERANS DRIVE
FP ID NO.
ST THOMAS
COUNTYROAD NO.
RTE 30
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DPC-34(1)
MAY, 2017
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
10 50
Feet
C01 0.000
C02 0.000
C03 0.000
C04 0.000
T01 0.000
T02 0.000
T03 0.000
T04 0.000
71.82' RT.
STA. 239+85.07
BEND POINT
71.53' RT.
STA. 239+95.07
BEND POINT
VETERANS DR.
¡ CONST.
56.01' RT.
STA. 240+67.32
BEND POINT
N
PBW9
PBW10
PBW11
PBW12
10'-0"
10'-0"
18" PIPE
30" PIPE
18" PIPE
18" PIPE
18" PIPE
424.97'
12.11'
15.66'
PBL5
PBL6
PBL7
42.43'
68.08' RT.
STA. 240+68.28
BEND POINT
68.81' RT.
STA. 240+57.78
BEND POINT
.4
.76'
.7 0'
65.49'
113.41' RT.
STA. 237+21.45
BEND POINT
63.83' RT.
STA. 236+73.31
BEGIN HARBOR WALL
75.18' RT.
PT STA. 238+13.94
56.17' RT.
STA. 239+84.62
BEND POINT
.5 'R
.0
R
PIPE
24"
EXTENSION
CULVERT
BOX
PIPE
18"
PIPE
18"
PIPE
18"
100.47' RT.
STA. 240+27.65
BEND POINT
PBW42 PBW43
SHEET W-16
CLOSURE DETAIL,
SEE C-I-P
M A
T C
H
L I N
E
S
T A
.0
PLAN
DIRECTION OF STATIONING
ST. THOMAS HARBOR
K A
N A
L
G
D E
H O
S P I T
L
D E
(1 OF 4)
WALL PLAN
W-3
= BOLLARD WITHOUT LIGHT
= BOLLARD WITH LIGHT
= APPROXIMATE BORING LOCATION
LEGEND:
STATIONS AND OFFSETS ARE TO FRONT FACE OF COPING.5.
WALL DETAILS.
SEE HARDSCAPE PLANS, SHEETS U-1 TO U-15 FOR ADDITIOINAL4.
SEE LIGHTING PLANS FOR LIGHTING LOCATIONS AND DETAILS.3.
SEE UTILITY RELOCATION PLANS FOR UTILITY INFORMATION. 2.
SEE ROADWAY PLANS FOR VERTICAL AND HORIZONTAL CURVE DATA.1.
NOTES:
PCC
STA.
5+
.75
PT STA. 248+74.95
24924
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:30:55 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallControl02.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
10 50
Feet
C
.0
C
.0
C
.0
C
.0
C
C
T
.0
T
.0
T
.0
T
.0
T
T
65.62' RT.
STA. 245+93.21
BEND POINT
99.04' RT.
STA. 245+86.02
BEND POINT
139.38' RT.
STA. 246+59.34
BEND POINT
98.04' RT.
STA. 247+31.37
BEND POINT
64.62' RT.
STA. 247+23.45
BEND POINT
VETERANS DR.
¡ CONST.
56.00' RT.
STA. 245+32.49
BEND POINT
83.21'
N
PBW13
PBW14
PBW15
PBW16
PBW17
18" PIPE
18" PIPE
18" PIPE
18" PIPE
18" PIPE
24" PIPE
18" PIPE
18" PIPE
18" PIPE
18" PIPE
18" PIPE
4.9
7'
52.09'
.66
.9
18.20' 18.20'
.0
46.69'
179.59'
PBL10
PBL8
PBL9
18" PIPE
101.69' RT.
STA. 246+10.27
BEND POINT
.6
.6
101.02' RT.
STA. 247+07.25
BEND POINT
56.00' RT.
PCC STA. 245+10.71
56.00' RT.
STA. 247+77.78
BEND POINT
56.00' RT.
PT STA. 248+74.943
.0
R
.0
R
.0
R
12.50'12.50'
PBW44
PBW45
PBW46M
A
T C
H
L
IN
E
S
T A
.0
M A
T C
H
L
IN
E
S T
A .0
PLAN
DIRECTION OF STATIONING
ST. THOMAS HARBOR
DE BELTJEN ROAD
B B
(2 OF 4)
W-4
FOR STAIR/WALL DETAIL SECTION B-B, SEE SHEET W-16.3.
FOR STAIR TYPICAL SECTION A-A, SEE SHEET W-14.2.
FOR ADDITIONAL NOTES, SEE SHEET W-31.
NOTES:
1.
.3
.1
.0
PC STA. 250+54.54
DESIGNED
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:32:04 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallControl03.DGNLawsonS
VETERANS DRIVE
FP ID NO.
ST THOMAS
COUNTYROAD NO.
RTE 30
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DPC-34(1)
MAY, 2017
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
10 50
Feet
91.25' RT.
STA. 252+03.20
BEND POINT
56.00' RT.
STA. 251+52.89
BEND POINT
84.40' RT.
STA. 252+43.45
BEND POINT
95.36' RT.
STA. 252+44.19
BEND POINT
94.65' RT.
STA. 252+52.17
BEND POINT
123.75' RT.
STA. 252+76.16
BEND POINT
95.52' RT.
STA. 253+08.21
BEND POINT
91.60' RT.
STA. 253+49.19
BEND POINT
56.00' RT.
STA. 254+00.57
BEND POINT
VETERANS DR.
¡ CONST.
.5
50.00' 50.00'
.8
.4
56.00' RT.
STA. 250+54.53
84.56' RT.
STA. 253+08.98
BEND POINT
N
PBW17
PBW18
PBW19
PBW20
11.00'
18" PIPE
18" PIPE
18" PIPE
18" PIPE
18" PIPE
18" PIPE
3.
11.00'
112.85'
179.59'
PBL11
PBL12
.4
94.76' RT.
STA. 253+00.23
BEND POINT
R
R
PBW47
PBW48 PBW49
PBW50
M A
T C
H
L
IN
E
S T
A .0
M A T C
H
LIN
E
S T
A .0
PLAN
DIRECTION OF STATIONING
ST. THOMAS HARBOR
DE BELTJEN ROAD
(3 OF 4)
W-5
FOR ADDITIONAL NOTES, SEE SHEET W-3.1.
NOTE:
5.32
2.77
5.52
5.39
3.66
PT STA. 25
7+00
.08
PC STA. 25
9+47
.51
PT STA. 261+50.29
POT S
TA. 261+79.04
P T
S
T A .2
P O T
S
T A .0
DESIGNED
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:32:30 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallControl04.DGNLawsonS
VETERANS DRIVE
FP ID NO.
ST THOMAS
COUNTYROAD NO.
RTE 30
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DPC-34(1)
MAY, 2017
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
10 50
Feet
VETERANS DR.
¡ CONST.
N
56.00' RT.
STA. 257+00.07
56.00' RT.
STA. 258+99.66
48.96' RT.
STA. 259+25.65
PBW20
PBW21 PBW22
18" PIPE
18" PIPE
18" PIPE
18" PIPE
18" PIPE24" PIPE
18" PIPE
18" PIPE
24" PIPE
24" PIPE
24" PIPE
30" PIPE
27.25'
343.64'
PBL13
PBL14
PBL15
.0
R
199.5 8'
43.83' RT.
STA. 259+34.42
¡ CONST. VETERANS DR.
END HARBOR WALL5
.5
R
.1
PBW51
M A
T C
H
L I N
E
S
T A
.0
PLAN
DIRECTION OF STATIONING
ST. THOMAS HARBOR
DE BELTJEN ROAD
(4 OF 4)
W-6
FOR ADDITIONAL NOTES, SEE SHEET W-3.1.
NOTE:
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:33:44 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallProfile01.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
-10
-5
-15
-20
-25
-35
-30
-45
-40
-50
-10
-5
-15
-20
-25
-35
-30
-45
-40
-50
(1 OF 4)
WALL PROFILE
.1
R
T
S T
A
.6
.8
R
T
S T
A
.0
.5
R
T
S T
A
.0
.8
R
T
S T
A
.7
.0
R
T
S T
A
.2
.0
R
T
S T
A
.3
.1
R
T
P T
S
T A
.9
.4
R
T
S T
A
.4
.8
R
T
S T
A
.3
B E
G I
H
R B
O R
W
L L
.4
R
T
S T
A
.6
114.36'58.00'96.00'416.00'100.00'44.00'119.56'42.00'74.00'138.00'310.00'90.00'102.00'96.00' 152.00'264.00'164.02'98.18'
FL EL. -0.43
STA. 240+16.86
30" PIPE
TOP OF COPING TOP OF COPING
P B
W
P B
W
P B
W
P B
W
U.N.O. (TYP.)
WALL BEND POINT
GROUND LINE ALONG WALL
APPROXIMATE EXISTING
343.64'70.85'50.00'
11.00'10.00'
42.43'42.43'
10.00'11.00'
50.00'69.56'112.85'179.59'83.21'46.69'34.00'18.20'50.63'50.63'18.20'33.90'52.09'18.66'424.97'
12.11'10.00'
42.43'42.43'
10.00'15.66'
171.76'86.70'65.49'
P B
W
P B
L
APPROXIMATE TOP OF ROCK
SCOUR ELEVATION
EL. -7.00' EL. -8.00'
EL. -9.00'
EL. -8.00'
EL. -7.00'
2528.12'
APPROXIMATE AREA OF SOILS REQUIRING REMOVAL
P B
W
FL EL. -1.60
STA. 237+57.52
24" PIPE FL EL. -1.61
STA. 241+20.00
18" PIPE
FL EL. -1.16
STA. 240+40.36
24" PIPE
FL EL. -0.64
STA. 242+86.41
BOX CULVERT CD-1
TOE OF PROPOSED WALL
FL EL. -0.34
STA. 236+79.95
18" PIPE
FL EL. -0.34
STA. 236+98.72
18" PIPE
HARBOR WALL - PARTIAL PROFILE
DIRECTION OF STATIONING
M A
T C
H
L I N
E
S
T A
.0
W-7
MLLW 0.00
MHHW 0.82
237+00 237+50 238+00 239+00238+50 239+50 240+00 240+50 241+00 241+50 242+00 242+50 243+00
50.00'
2528.00'
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:34:08 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallProfile02.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
-10
-5
-15
-20
-25
-35
-30
-45
-40
-50
-10
-5
-15
-20
-25
-35
-30
-45
(2 OF 4)
.0
R
T
S T
A
.4
.6
R
T
S T
A
.2
.0
R
T
S T
A
.0
.0
R
T
S T
A
.3
.6
R
T
S T
A
.4
.0
R
T
S T
A
.7
.6
R
T
S T
A
.2
.3
R
T
S T
A
.3
.0
R
T
S T
A
.2
.0
R
T
P C
C
S
T A
.7
.0
R
T
P T
S
T A
.9
114.36'58.00'96.00'416.00'100.00'44.00'119.56'42.00'74.00'138.00'310.00'90.00'102.00'96.00' 152.00'264.00'164.02'98.18'
FL EL. -1.05
STA. 249+70.00
18" PIPE
TOP OF COPING
P B
W
P B
W
P B
W
P B
W
P B
W
P B
L
U.N.O. (TYP.)
WALL BEND POINT
STEPS
TOP OF COPING
343.64'70.85'50.00'
11.00'10.00'
42.43'42.43'
10.00'11.00'
50.00'69.56'112.85'179.59'83.21'46.69'34.00'18.20'50.63'50.63'18.20'33.90'52.09'18.66'424.97'
12.11'10.00'
42.43'42.43'
10.00'15.66'
171.76'86.70'65.49'
APPROXIMATE TOP OF ROCK
SCOUR ELEVATIONEL. -11.00'
GROUND LINE ALONG WALL
APPROXIMATE EXISTING
EL. -8.00'
EL. -9.00'
EL. -10.00'
2528.12'
APPROXIMATE AREA OF SOILS REQUIRING REMOVAL
P B
W
P B
W
FL EL. -0.68
STA. 243+94.29
18" PIPE
FL EL. -1.45
STA. 245+50.88
24" PIPE
TOE OF PROPOSED WALL
HARBOR WALL - PARTIAL PROFILE
DIRECTION OF STATIONING
M A
T C
H
L I N
E
S
T A
.0
W-8
M A
T C
H
L I N
E
S
T A
.0
MLLW 0.00
MHHW 0.82
243+50 244+00 244+50 245+00 245+50 246+00 246+50 247+00 247+50 248+00 248+50 249+00 249+50
424.97'
50.00' 138.00'
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:34:30 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallProfile03.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
-10
-5
-15
-20
-25
-35
-30
-45
-40
-50
-10
-5
-15
-20
-25
-35
-30
-45
(3 OF 4)
.0
R
T
S T
A
.8
.2
R
T
S T
A
.2
.4
R
T
S T
A
.4
.3
R
T
S T
A
.1
.6
R
T
S T
A
.1
.7
R
T
S T
A
.2
.5
R
T
S T
A
.2
.5
R
T
S T
A
.9
.6
R
T
S T
A
.1
.0
R
T
S T
A
.5
.7
R
T
S T
A
.1
.0
R
T
P C
S
T A
.5
114.36'58.00'96.00'416.00'100.00'44.00'119.56'42.00'74.00'138.00'310.00'90.00'102.00'96.00' 152.00'264.00'164.02'98.18'
TOP OF COPING
P B
W
P B
W
P B
L
P B
W
U.N.O. (TYP.)
WALL BEND POINT
343.64'70.85'50.00'
11.00'10.00'
42.43'42.43'
10.00'11.00'
50.00'69.56'112.85'179.59'83.21'46.69'34.00'18.20'50.63'50.63'18.20'33.90'52.09'18.66'424.97'
12.11'10.00'
42.43'42.43'
10.00'15.66'
171.76'86.70'65.49'
EL. -13.00'
EL. -12.00'
EL. -11.00'
GROUND LINE ALONG WALL
APPROXIMATE EXISTING
EL. -12.00'
EL. -13.00'
EL. -12.00'
APPROXIMATE TOP OF ROCK
TOE OF PROPOSED WALL
2528.12'
APPROXIMATE AREA OF SOILS REQUIRING REMOVAL
P B
W
P B
W
P B
W
SCOUR ELEVATION
HARBOR WALL - PARTIAL PROFILE
DIRECTION OF STATIONING
M A
T C
H
L I N
E
S
T A
.0
M A
T C
H
L I N
E
S
T A
.0
W-9
2528.10'
MLLW 0.00
MHHW 0.82
250+00 250+50 251+00 251+50 252+00 252+50 253+00 253+50 254+00 254+50
179.59' 343.64'
416.00'138.00'
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:34:50 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallProfile04.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
-10
-5
-15
-20
-25
-35
-30
-45
-40
-50
-10
-5
-15
-20
-25
-35
-30
-45
(4 OF 4)
.0
R
T
P T
S
T A
.0
.0
R
T
P C
S
T A
.6
.9
R
T
P T
S
T A
.6
.8
R
T
S T
A
.4
E
R B
O R
L L
114.36'58.00'96.00'416.00'100.00'44.00'119.56'42.00'74.00'138.00'310.00'90.00'102.00'96.00' 152.00'264.00'164.02'98.18'
FL EL. 0.65
STA. 256+19.00
18" PIPE
TOP OF COPING
P B
L
P B
W
P B
L
P B
W
P B
W
GROUND LINE ALONG WALL
APPROXIMATE EXISTING
343.64'70.85'50.00'
11.00'10.00'
42.43'42.43'
10.00'11.00'
50.00'69.56'112.85'179.59'83.21'46.69'34.00'18.20'50.63'50.63'18.20'33.90'52.09'18.66'424.97'
12.11'10.00'
42.43'42.43'
10.00'15.66'
171.76'86.70'65.49'
APPROXIMATE TOP OF ROCK
EL. -15.00'
EL. -14.00'
EL. -13.00'
EL. -12.00'
10.15'
27.25'199.58'
2528.12'
APPROXIMATE AREA OF SOILS REQUIRING REMOVAL
P B
W
P B
W
TOE OF PROPOSED WALL SCOUR ELEVATION
HARBOR WALL - PARTIAL PROFILE
DIRECTION OF STATIONING
M A
T C
H
L I N
E
S
T A
.0
W-10
2528.10'
MLLW 0.00
255+00 255+50 256+00 256+50 257+00 257+50 258+00 258+50 259+00
MHHW 0.82
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:35:52 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallGeometry.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
W-11
WALL GEOMETRY
GEOMETRY WALLHARBOR
LOCATION STATION OFFSET
NELEVATIO
PGL
NELEVATIO
GROUND
EXISTING
NELEVATIO
COPING
WALL
WALLBEGIN 236+73.31 63.83 3.80 3.51 2.40
LINEBEND 237+21.45 113.41 4.25 -3.13 4.22
237+25.50 110.65 4.27 -3.14 4.24
237+41.71 100.77 4.34 -3.03 4.30
237+58.70 92.28 4.42 -2.89 4.37
237+76.32 85.21 4.49 -2.71 4.40
237+94.42 79.62 4.57 -2.70 4.71
238+10.61 75.73 4.64 -2.81 4.91
PT 238+13.94 75.18 4.65 -2.88 4.92
238+33.71 72.98 4.72 -2.92 5.00
238+57.42 70.34 4.79 -2.84 5.08
238+81.12 67.70 4.87 -2.78 5.16
239+04.84 65.05 4.94 -2.76 5.19
239+28.59 62.41 4.99 -2.79 5.11
239+52.39 59.76 4.91 -2.79 4.74
239+76.24 57.10 4.84 -2.76 4.75
OVERLOOKBEGIN 239+84.62 56.17 4.81 -2.39 4.76
LINEBEND 239+85.08 71.82 4.80 -3.00 4.61
LINEBEND 239+95.07 71.53 4.77 -2.95 4.61
OVERLOOKCL 240+27.65 100.47 4.68 -3.60 4.24
LINEBEND 240+57.78 68.81 4.59 -3.23 4.41
LINEBEND 240+68.29 68.08 4.56 -3.22 4.41
OVERLOOKEND 240+67.33 56.01 4.56 -3.00 4.50
240+75.00 56.00 4.54 -3.00 4.49
241+00.00 56.00 4.46 -2.96 4.41
241+25.00 56.00 4.42 -2.95 4.37
241+50.00 56.00 4.49 -2.98 4.44
241+75.00 56.00 4.57 -3.02 4.52
242+00.00 56.00 4.64 -3.00 4.59
242+25.00 56.00 4.72 -3.05 4.67
242+50.00 56.00 4.79 -2.92 4.74
242+75.00 56.00 4.87 -2.92 4.82
243+00.00 56.00 4.94 -2.88 4.89
243+25.00 56.00 5.02 -3.00 4.97
243+50.00 56.00 5.09 -3.22 5.04
243+75.00 56.00 5.17 -3.59 5.12
244+00.00 56.00 5.24 -3.82 5.19
244+25.00 56.00 5.32 -3.88 5.27
244+50.00 56.00 5.39 -3.90 5.34
244+75.00 56.00 5.47 -4.03 5.42
245+00.00 56.00 5.54 -4.13 5.49
PT 245+10.71 56.00 5.57 -4.00 5.52
245+25.00 56.00 5.62 -4.11 5.57
LINEBEND 245+32.49 56.00 5.64 -3.85 5.59
245+50.00 59.66 5.69 -4.03 5.57
245+75.00 63.62 5.77 -4.32 5.80
STEPSWITH
OVERLOOKBEGIN
245+93.21 65.62 5.82 -4.69
5.58
3.13
COPINGEND 246+09.95 67.43 5.87 -4.81 5.59
LINEBEND 245+86.02 99.04 5.80 -5.34 3.13
LINEBEND 246+10.27 101.69 5.87 -5.45 3.13
OVERLOOKCL 246+59.34 139.38 6.02 -6.06 3.13
LINEBEND 247+07.25 101.02 6.16 -5.56 3.13
LINEBEND 247+31.37 98.04 6.17 -5.47 3.13
COPINGBEGIN 247+06.58 65.28 6.16 -4.30 5.95
STEPSWITH
OVERLOOKEND
247+23.45 64.62 6.19 -4.38
3.13
5.97
TOP ELEVATION
* MATCH EXISTING SEAWALL
(CONTINUED) GEOMETRY WALLHARBOR
LOCATION STATION OFFSET
NELEVATIO
PGL
NELEVATIO
GROUND
EXISTING
NELEVATIO
COPING
WALL
247+50.00 61.26 6.11 -4.59 5.96
247+75.00 56.61 6.04 -4.51 5.98
LINEBEND 247+77.78 56.00 6.03 -4.50 5.98
248+00.00 56.00 5.96 -4.73 5.91
248+25.00 56.00 5.89 -4.47 5.84
248+50.00 56.00 5.81 -4.49 5.76
PC 248+74.94 56.00 5.74 -4.51 5.69
248+75.00 56.00 5.74 -4.51 5.69
249+00.00 56.00 5.66 -4.64 5.61
249+25.00 56.00 5.59 -4.53 5.54
249+50.00 56.00 5.51 -4.51 5.46
249+75.00 56.00 5.47 -4.54 5.42
250+00.00 56.00 5.56 -4.78 5.51
250+25.00 56.00 5.64 -4.69 5.59
250+50.00 56.00 5.73 -4.66 5.68
PT 250+54.53 56.00 5.75 -4.63 5.70
250+75.00 56.00 5.82 -4.56 5.77
251+00.00 56.00 5.91 -4.00 5.86
251+25.00 56.00 5.99 -4.34 5.94
251+50.00 56.00 6.08 -4.23 6.03
OVERLOOKBEGIN 251+52.89 56.00 6.09 -4.16 6.05
LINEBEND 252+03.20 91.25 6.27 -4.40 5.93
LINEBEND 252+43.45 84.40 6.41 -3.01 5.93
LINEBEND 252+44.19 95.36 6.41 -4.00 5.87
LINEBEND 252+52.17 94.65 6.44 -3.65 5.87
OVERLOOKCL 252+76.16 123.75 6.52 -5.63 5.87
LINEBEND 253+00.23 94.76 6.61 -4.25 6.07
LINEBEND 253+08.21 95.52 6.64 -3.93 6.12
LINEBEND 253+08.98 84.56 6.64 -3.94 6.18
LINEBEND 253+49.19 91.60 6.78 -5.77 6.39
OVERLOOKEND 254+00.57 56.00 6.75 -3.99 6.70
254+25.00 56.00 6.68 -4.39 6.63
254+50.00 56.00 6.60 -5.36 6.55
254+75.00 56.00 6.53 -6.71 6.48
255+00.00 56.00 6.45 -7.81 6.40
255+25.00 56.00 6.38 -8.54 6.33
255+50.00 56.00 6.30 -8.95 6.25
255+75.00 56.00 6.23 -9.12 6.18
256+00.00 56.00 6.15 -9.03 6.10
256+25.00 56.00 6.12 -9.07 6.07
256+50.00 56.00 6.19 -9.06 6.14
256+75.00 56.00 6.27 -8.98 6.22
257+00.00 56.00 6.34 -8.46 6.29
PT 257+00.07 56.00 6.34 -8.45 6.29
257+25.00 56.00 6.42 -7.80 6.37
257+50.00 56.00 6.49 -7.93 6.44
257+75.00 56.00 6.57 -7.97 6.52
258+00.00 56.00 6.64 -7.86 6.59
258+25.00 56.00 6.72 -7.80 6.67
258+50.00 56.00 6.79 -6.88 6.74
258+75.00 56.00 6.87 -7.30 6.82
259+00.00 56.00 6.94 -7.61 6.89
PC 258+99.66 56.00 6.94 -7.51 6.89
PT 259+25.65 48.96 7.02 0.20 6.97
259+25.00 49.29 7.02 0.25 7.13
WALLEND 259+34.42 43.83 7.04 4.05 7.10
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:36:37 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\ConstSeq01.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
W-12
PHASE 1
PHASE 2
PHASE 4
PHASE 5
FINAL
CONSTRUCT SIDEWALK.3.
INSTALL WALL COPING.2.
CONSTRUCT ROADWAY.1.
CONSTRUCTION SEQUENCE
BACKFILL.4.
ADJUST BLOCK AS REQUIRED.3.
VERIFY HORIZONTAL AND VERTICAL GEOMETRY OF BLOCK.2.
PLACE FIRST BLOCK ON BEDDING STONE FOUNDATION.1.
COMPACT BACKFILL.5.
BACKFILL.4.
ADJUST BLOCK AS REQUIRED.3.
VERIFY HORIZONTAL AND VERTICAL GEOMETRY OF BLOCKS.2.
PLACE ADDITIONAL BLOCKS ABOVE WATERLINE.1.
PHASE 3
BACKFILL.4.
ADJUST BLOCK AS REQUIRED.3.
VERIFY HORIZONTAL AND VERTICAL GEOMETRY OF BLOCKS.2.
PLACE ADDITIONAL BLOCKS BELOW WATERLINE.1.
PLACE AND LEVEL BEDDING STONE FOUNDATION.3.
SUBMIT RESULTS TO CO FOR APPROVAL.
CONTRACTOR TO VERIFY MINIMUM BEARING CAPACITY OF SOIL AND2.
REMOVE SOILS, DEBRIS AND RIP-RAP ETC. AS DIRECTED BY THE CO.1.
REMOVE SOIL SURCHARGE WHEN SETTLEMENT HAS BEEN MET.4.
MONITOR SOIL SETTLEMENT.3.
PLACE SOIL SURCHARGE IN ROADWAY EMBANKMENT AREA.2.
REPLACE REMAINING SOILS AS DIRECTED BY CO.1.
WALL TYPICAL SECTION
W-13
(SHOWN AT STA. 247+50)
BOLLARDS (SEE ARCHITECTURAL PLANS FOR LOCATIONS)
LIGHTS AND CONDUIT (SEE ELECTRICAL PLANS FOR DETAILS)
TOP OF BLOCK
FRONT FACE OF QUAY WALL
GEOTEXTILE FABRIC
MLLW 0.00
MHHW 0.82
TYPICAL SECTION
EXISTING GROUND LINETO MATCH EXISTING SOILS
2'-0" MINIMUM BACKFILL
SIDEWALK AND PAVERS (SEE ARCHITECTURAL PLANS FOR DETAILS)
BOTTOM BLOCK DEPTH
H E I G
H T
L
H
L E
V E
L I
P
TOP OF WALL COPING
E I G
H T
H
Q U
Y
L L
(MINIMUM)
12"
10'-0" (MAXIMUM)
TEMPORARY EXCAVATION
12" (MIN.)
LH/2
12" (MIN.)
LH/2
(WORKING POINT)
VERTICAL GEOMETRY
HORIZONTAL AND
1 4
Feet
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
3.5
3.0
3.0
4.0
5.0
5.5
6.0
6.5
7.0
7.5
8.0
(FT)
DEPTH
BLOCK
MINIMUM
(FT)
(H)
HEIGHT
QUAY WALL
BLOCK DIMENSIONS
TABLE OF QUAY WALL
(SEE GENERAL NOTES)
RECYCLED RIP-RAP
(#4 STONE)
DRAINAGE FILL
S T
O N
E
M
N I
M U
M
EMBANKMENT
ELEVATION
TOE OF WALL WHERE REQUIRED (SEE WALL PROFILE SHEETS)
NOT MEETING BEARING CAPACITY CRITERIA,
OVEREXCAVATE POOR FOUNDATION SOILS
GEOTECHNICAL REPORT.
FOR EMBANKMENT RECOMMENDATIONS, REFER TO3.
WILL HAVE DIFFERENT MINIMUM BLOCK DEPTHS.
BLOCKS WITH HEIGHTS GREATER OR LESS THAN 2.0 FT2.
ON AN INDIVIDUAL BLOCK HEIGHT OF 2.0 FT.
MINIMUM BLOCK DEPTHS SHOWN ARE BASED1.
NOTES:
DESIGNED
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:37:29 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallQuayWallDet02.dgnLawsonS
VETERANS DRIVE
FP ID NO.
ST THOMAS
COUNTYROAD NO.
RTE 30
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DPC-34(1)
MAY, 2017
Miami, FL 33126 Ph. (305) 514-3100
STAIR TYPICAL SECTION
W-14
FRONT FACE OF QUAY WALL
GEOTEXTILE FABRIC
MLLW 0.00
MHHW 0.82
EXISTING GROUND LINETO MATCH EXISTING SOILS
2'-0" MINIMUM BACKFILL
BOTTOM BLOCK DEPTH
H E I G
H T
L
H
L E
V E
L I
P
E I G
H T
H
Q U
Y
L L
(MINIMUM)
12"
10'-0" (MAXIMUM)
TEMPORARY EXCAVATION
12" (MIN.)
LH/2
12" (MIN.)
LH/2
Slope: 0.01 Ft/Ft
1 4
Feet
(BETWEEN STA. 245+93.21 AND 247+03.50)
TYPICAL STAIR - SECTION A-A
(#4 STONE)
DRAINAGE FILL
T
O N
E
M
N I
M U
M
(SEE GENERAL NOTES)
RECYCLED RIP-RAP
TOP OF WALL COPING
SIDEWALK AND PAVERS (SEE ARCHITECTURAL PLANS FOR DETAILS)
TOP OF BLOCK
5'-6" 10'-0"
T Y
P
(WORKING POINT)
VERTICAL GEOMETRY
HORIZONTAL AND
= 4'-0"
4 SPA. @ 1'-0"
1'-6"
AND PAVING DETAILS
PLANS FOR SIDEWALK
SEE ARCHITECTURAL
#4 BARS @ 12" (TYP.)
#3 BAR EACH NOSING (TYP.)
#3 BAR (TYP.)
EMBANKMENT
ELEVATION
TOE OF WALL
WHERE REQUIRED (SEE WALL PROFILE SHEETS)
NOT MEETING BEARING CAPACITY CRITERIA,
OVEREXCAVATE POOR FOUNDATION SOILS
DESIGNED
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:37:58 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallQuayWallDet03.dgnLawsonS
VETERANS DRIVE
FP ID NO.
ST THOMAS
COUNTYROAD NO.
RTE 30
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DPC-34(1)
MAY, 2017
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:38:32 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallQuayWallDet04.DGNLawsonS
VETERANS DRIVE
FP ID NO.
DPC-34(1)ST THOMAS
COUNTYROAD NO.
RTE 30
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DESIGNED
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
Miami, FL 33126 Ph. (305) 514-3100
7650 Corporate Center Dr., Suite 300
MAY, 2017
0.5 2
Feet
VARIES
CLEARANCE
SP. (TYP.)
#5 BARS @ 12" MAX.
" OPEN JOINT2
1¡
" OPEN JOINT SPACING ~ 30'-
0" TYPICAL (10'-0"
MIN.)
COPING
TOP OF C-I-P
" OPEN JOINT2
1¡
C-I-P COPING
BOTTOM OF
WALL PANEL (TYP.)
TOP OF QUAY
PANELS (TYP.)
RETAINING WALL
COPING)
SLOPE OF C-I-P
#5 BARS (FOLLOWS
6"R
3"R
1"3"
"4
"2 11 "4
R"2
"4
V
R I E
S
BLOCK
OF
TOP
TOP OF COPING
SPACING #5 BARS
VARIES (CURVED AREAS)
9" (TANGENT AREAS)
COPING OVERHANG
BLOCK QUAY WALL
PRECAST CONCRETE
#5 @ 12" O.C.
M I N
PLANS FOR DETAILS)
(SEE ARCHITECTURAL
SIDEWALK AND PAVERS
P A
SPACING #3 STURRIPS
SPACING #5 BARS
(2) SETS OF #4 BARS
VARIES1'-6"
V
R I E
S
BLOCK
OF
TOP
VARIES (CURVED AREAS)
9" (TANGENT AREAS)
COPING OVERHANG
BLOCK QUAY WALL
PRECAST CONCRETE
PLANS FOR DETAILS)
(SEE ARCHITECTURAL
SIDEWALK AND PAVERS
TOP OF COPING
#5 @ 12" O.C.
M I N
(SEE ELECTRICAL PLANS FOR DETAILS)
LIGHTS, PULL BOX, AND CONDUIT
FOR DIMENSIONS AND LOCATIONS)
BOLLARDS (SEE ARCHITECTURAL PLANS
(WORKING POINT)
VERTICAL GEOMETRY
HORIZONTAL AND
(WORKING POINT)
VERTICAL GEOMETRY
HORIZONTAL AND
W-15
(1 OF 2)
WALL COPING DETAILS
A
A
CAST-IN-PLACE COPING - PARTIAL ELEVATION VIEW
COPING EDGE DETAIL
3" CL.
(TYP.)
SECTION A-A
CAST-IN-PLACE COPING AT STAIRS
(BETWEEN STA. 245+93.21 AND 247+03.50)
3" CL.
(TYP.)
CAST-IN-PLACE COPING ALONG BLOCK WALL
SECTION A-A
W-16
OVERLAP
3" MIN.
C
C
MAX.
6"
WALL
RETAINING
BEGIN
COPING
TOP OF
WALL END PANEL
TOP OF QUAY
SEA WALL
EXISTING
COPING
BOTTOM OF
COPING ENCLOSURE
EDGE OF C-I-P
PANEL
QUAY WALL
WALL END PANEL
EDGE OF QUAY
QUAY WALL SHOWN
LEVELING PAD FOR
C-I-P CLOSURE DETAIL
1'-0"
" CHAMFER (TYP.)4
V A
R I E
S
M I N
SECTION C-C
(2 OF 2)
WALL COPING DETAILS
TOP OF WALL COPING
END CURVED COPING DETAIL EDGE OF OVERLOOK CAP BLOCK
SHOWN.
FOR INFO NOT
STAIR SECTION
SEE TYPICAL
PLANS FOR DETAILS)
(SEE ARCHITECTURAL
SIDEWALK AND PAVERS
PLANS FOR DETAILS)
(SEE ARCHITECTURAL
BOLLARDS
STAIR/WALL DETAIL - SECTION B-B
APPROX. STA. 246+00 (SHOWN), APPROX. STA. 247+00 (OPP. HAND)
0.5 2
Feet
ANCHORS @ ±10' ON CENTER
WITH GALVANIZED CONCRETE
8" HEAVY DUTY DOCK CLEATS
INSTALL HOT DIPPED GALVANIZED
CAP BLOCK
PRECAST CONCRETE
CONCRETE STEPS
DESIGNED
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:39:33 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallQuayWallDet05.dgnLawsonS
VETERANS DRIVE
FP ID NO.
ST THOMAS
COUNTYROAD NO.
RTE 30
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DPC-34(1)
MAY, 2017
W-17
WALL PIPE PENETRATION DETAILS
THRU WALL
PIPE PENETRATION
2"
1'-0"
BACKFILL
GROUT COLLAR
GEOTEXTILE FABRIC
PIPE PENETRATION DETAIL - SECTION D-D
AROUND PENETRATION.
IN THE PRIMARY LAYER
TO COVER ANY OPENINGS
LAYER OF FILTER FABRIC
WRAP PIPE WITH ADDITIONAL
STAINLESS STEEL CLAMP
THRU WALL
PIPE PENETRATION
PRECAST CONCRETE BLOCK QUAY WALL
CAST-IN-PLACE CONCRETE COPING
CAST-IN-PLACE CONCRETE COPING
PRECAST CONCRETE BLOCK QUAY WALL
AROUND PIPE
GROUT COLLAR
THRU WALL
PIPE PENETRATION
CAST-IN-PLACE CONCRETE COPING
PRECAST CONCRETE BLOCK QUAY WALL
D
D
AROUND PIPE
GROUT COLLAR
TO FIT PIPE THROUGH WALL
NUMBER OF BLOCKS REQUIRED
REMOVE ONLY THE MINIMUM
TO FIT PIPE THROUGH WALL
NUMBER OF BLOCKS REQUIRED
REMOVE ONLY THE MINIMUM
(TYP.)
3"
(TYP.)
3"
1 4
Feet
PIPE PENETRATION DETAIL 1
USE WHEN PIPE OUTSIDE DIAMETER IS LESS THAN BLOCK HEIGHT
1 4
Feet
PIPE PENETRATION DETAIL 2
USE WHEN PIPE OUTSIDE DIAMETER IS EQUAL OR GREATER THAN BLOCK HEIGHT
(#4 STONE)
UNIT DRAINAGE FILL
DESIGNED
MODEL NAME = DefaultPEN TABLE = $PENTBLL$PLOT DRIVER = $PLTDRVL$ 5/11/2017 1:40:16 PM T:\Sys\Projects\Veterans Drive\2014 CADD Files Phase 1\Struct\WallQuayWallDet06.dgnLawsonS
VETERANS DRIVE
FP ID NO.
ST THOMAS
COUNTYROAD NO.
RTE 30
Scott R. Lawson, P.E., No. 1295-E
ENGINEER OF RECORD
J. HARTSHORN
JTM
DRAWN
CHECKED
DATE
R E V I S I O N S
DESCRIPTIONBYDATE
U.S.V.I.
DEPARTMENT OF PUBLIC WORKS
DPC-34(1)
MAY, 2017