Attachment 15 - Hangar 8 E Addendum 2.pdf
PDF 114 KB Posted
- Attached to
- CONSTRUCTION: Hangar 08 & 09 Mechanical Upgrades at the Mike Monroney Aeronautical Center, Oklahoma City, OK
- Solicitation number
- DTFAAC-17-R-00023
About this file
Attachment 15 - Hangar 8 E Addendum 2 (pdf)
View the file
Other files
Show 40 more
Latest 50 of 174 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
SC
J J J
F F F
SIMPLEX RECEPTACLE, NEMA 5-20R
DUPLEX RECEPTACLE
QUADRUPLEX RECEPTACLE
DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER
WEATHERPROOF DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER
ELECTRICAL RECEPTACLE AT SPECIFIED HEIGHT
ELECTRICAL RECEPTACLE AT 2" ABOVE COUNTER OR BACKSPLASH
SPECIAL PURPOSE OUTLET WITH CONFIGURATION SHOWN ON PLANS PER NEMA
WD-6.
SIMPLEX FLOOR RECEPTACLE, NEMA 5-20R
DUPLEX FLOOR RECEPTACLE
QUADRUPLEX FLOOR RECEPTACLE
SPECIAL PURPOSE FLOOR OUTLET WITH CONFIGURATION SHOWN ON PLANS PER
NEMA WD-6.
DUPLEX CEILING RECEPTACLE
RECEPTACLE SYMBOLS
WP
44"
C
CONDUIT, BELOW GRADE OR FLOOR SLAB
CONDUIT TURNING UP
CONDUIT TURNING DOWN
CONDUIT TERMINATED AND CAPPED
CONDUIT CONTINUES AS INDICATED
JUNCTION BOX, MOUNTED ABOVE CEILING, WALL MOUNTED, OR
FLOOR MOUNTED
FURNITURE CONNECTION JUNCTION BOX, MOUNTED ABOVE CEILING, WALL
MOUNTED, OR FLOOR MTD
POWER POLE
HOME RUN, MIN 3/4" CONDUIT CONTAINING 2#12 AWG CU CONDUCTORS
PER
CIRCUIT AND 1#12 AWG CU GROUND, UNO
BRANCH CIRCUIT. SLASHES INDICATE THE NUMBER OF CONDUCTORS. MIN
3/4"
CONDUIT, 1#12 GND, 1#12 PH, 1#12 NEU CU, UNO
SPLIT CIRCUIT
CONDUIT & WIRING SYMBOLS
GROUNDING & LIGHTNING PROTECTION
T
GROUND LOOP CONDUCTOR, 2/0 AWG BARE CU, UNO,
BURIED MINIMUM 30" BELOW FINISHED GRADE.
EXOTHERMIC WELD CONNECTION
LIGHTNING PROTECTION MAIN CONDUCTOR
LIGHTNING PROTECTION CABLE CONNECTION
COPPER-CLAD GROUND ROD, 3/4" DIA X 10' L, DRIVEN 6"
BELOW FINISHED GRADE
LIGHTNING PROTECTION AIR TERMINAL
GROUND ELECTRODE
THRU ROOF UNIT WITH CABLE RUNNING TO LOWER LEVEL
THRU ROOF UNIT WITH CABLE RUNNING CONCEALED TO
GROUND ELECTRODE
COPPER GROUND BUS BAR ON INSULATED STANDOFF
INSULATORS
GROUND TEST WELL
LIGHTING SYMBOLS
CEILING LIGHT FIXTURE, 2' X 4', RECESSED OR SURFACE
MOUNTED AS SCHEDULED
CEILING LTG FIXTURE, 2' X 4', RECESSED OR SURFACE MTD
AS SCHEDULED, W/ EMERGENCY BATTERY PACK
CEILING LIGHT FIXTURE, 2' X 2', RECESSED OR SURFACE
MOUNTED AS SCHEDULED
CEILING LIGHT FIXTURE, 2' X 2', RECESSED OR SURFACE
MTD AS SCHEDULED, W/ EMERGENCY BATTERY PACK
LINEAR CEILING LIGHT FIXTURE, RECESSED OR SURFACE
MOUNTED AS SCHEDULED
LINEAR CEILING LIGHT FIXTURE, RECESSED OR SURFACE
MTD AS SCHED, W/ EMER BATTERY PACK
LINEAR LIGHT FIXTURE, WALL MOUNTED
LINEAR LIGHT FIXTURE, WALL MOUNTED, WITH
INTEGRAL EMERGENCY BATTERY PACK
STRIP LIGHT FIXTURE, SURFACE MOUNTED
STRIP LIGHT FIXTURE, SURFACE MOUNTED, WITH
INTEGRAL EMERGENCY BATTERY PACK
DOWNLIGHT FIXTURE, RECESSED
DOWNLIGHT FIXTURE, RECESSED, WITH INTEGRAL
EMERGENCY BATTERY PACK
LIGHT FIXTURE, WALL MOUNTED
LIGHT FIXTURE, WALL MOUNTED, WITH INTEGRAL
EMERGENCY
PENDANT LIGHT FIXTURE
RECESSED WALL WASH LIGHT FIXTURE
EMERGENCY DUAL-HEAD LIGHT FIXTURE, WALL MTD, WITH
INTEGRAL EMERGENCY BATTERY PACK
EXIT LIGHTING W/ DIRECTIONAL ARROWS, CEILING
MOUNTED. DARKENED SECTION(S) DENOTE FACE(S)
EXIT LIGHTING W/ DIRECTIONAL ARROWS, WALL
MOUNTED. DARKENED SECTION(S) DENOTE FACE(S)
POLE AND POLE MOUNTED EXTERIOR LIGHT FIXTURE
EXTERIOR LIGHT FIXTURE
EXISTING POLE AND POLE MOUNTED EXTERIOR LIGHT
FIXTURE
EXISTING EXTERIOR LIGHT FIXTURE
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
GENERAL NOTES:
1. PROVIDE A COMPLETE, OPERATIONAL AND TESTED ELECTRICAL SYSTEM. FURNISH AND INSTALL THE INDICATED LISTED AND TESTED EQUIPMENT AND SYSTEMS, COMPLETE WITH FINAL ELECTRICAL POWER AND
CONTROL CONNECTIONS. PROVIDE SPECIFICATION GRADE EQUIPMENT, UNLESS NOTED OTHERWISE.
2. MATERIALS PROVIDED IN THIS PROJECT SHALL BE NEW, UNLESS NOTED OTHERWISE.
3. WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT EDITIONS BEING ENFORCED BY THE AUTHORITY HAVING JURISDICTION OF THE NATIONAL ELECTRICAL CODE, THE NATIONAL ELECTRICAL
SAFETY CODE, AND APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND ORDINANCES.
4. INSTALLATION SHALL BE ACCORDING TO THE ACCEPTED INDUSTRY PRACTICES DESCRIBED IN NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION STANDARD ANSI/NECA 1-2015.
5. NOTIFY THE ELECTRIC UTILITY OF THIS PROJECT AND ARRANGE FOR INCOMING SERVICE. OBTAIN ANY REQUIRED INSTALLATION DETAILS. OBTAIN AND PAY THE FEES FOR THE REQUIRED ELECTRICAL PERMITS AND
CERTIFICATES.
6. COORDINATE THE EXACT LOCATION OF EQUIPMENT TO BE INSTALLED WITH OTHER TRADES FOR PROPER CLEARANCES.
7. COORDINATE POWER REQUIREMENTS FOR MECHANICAL EQUIPMENT PRIOR TO FINAL ROUGH IN AND INSTALLATION. LOCATE ROOF PENETRATIONS PER THE MANUFACTURER’S INSTALLATION INSTRUCTIONS.
REFER TO ARCHITECTURAL FOR ROOF PENETRATION REQUIREMENTS.
8. INSTALLATION OF MECHANICAL SYSTEMS, PLUMBING, AND FIRE-SUPPRESSION SYSTEMS HAVE PRIORITY OVER THE ELECTRICAL INSTALLATION. YIELD TO CONFLICTS WITH THEM AT NO ADDITIONAL COST TO THE
OWNER.
9. REFER TO THE MECHANICAL SHEETS FOR CONTROL DIAGRAMS AND WIRING TO THEIR EQUIPMENT.
10. REPLACE, AT NO ADDITIONAL EXPENSE TO THE OWNER, ANY ITEM THAT IS MARRED, DEFACED, OR BROKEN PRIOR TO ACCEPTANCE BY OWNER. AS AN ALTERNATE, REMEDIATION BY TOUCH-UP OR REFINISHING IS
AT THE SOLE DISCRETION OF THE ARCHITECT.
11. ELECTRICAL PLANS ARE DIAGRAMMATIC; FOLLOW THEM AS CLOSELY AS ACTUAL CONDITIONS WILL ALLOW. THE APPROVAL OF THE ARCHITECT MUST BE OBTAINED BEFORE DEVIATIONS FROM THESE PLANS ARE
MADE.
12. VERIFY FIELD CONDITIONS BEFORE BEGINNING WORK.
13. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION.
14. INFORM THE ARCHITECT OF EXISTING CONDITIONS THAT ARE DISCOVERED DURING WORK IN PROGRESS THAT WOULD REQUIRE DEVIATIONS AND ADDITIONAL COSTS FROM THE ORIGINAL CONSTRUCTION
DOCUMENTS BEFORE PROCEEDING WITH WORK.
15. WHERE DEVICES ARE SHOWN SIDE BY SIDE CONTROLLING DIFFERENT VOLTAGES, OR WHERE NORMAL AND EMERGENCY SYSTEMS ARE PRESENT, PROVIDE SEPARATE BOXES AND PLATES. DO NOT RUN
EMERGENCY POWER SYSTEMS IN THE SAME RACEWAYS AS NORMAL POWER SYSTEMS.
16. COORDINATE MOUNTING OF OUTLETS OVER COUNTERS WITH ARCHITECTURAL ELEVATIONS BEFORE INSTALLATION.
17. PROVIDE PVC COATED OR TAPED RGS ELBOWS WHERE STUBBED UP THROUGH SLAB. EXPOSED EXTERIOR CONDUIT MUST BE RGS, RMC OR SCHEDULE 40 PVC, UNLESS NOTED OTHERWISE.
18. DEVICES AND APPLIANCES SHALL BE UL LISTED AND SUITABLE FOR THE USE INTENDED.
19. ELECTRICAL EQUIPMENT SHALL BE IDENTIFIED WITH LAMINATED MELAMINE PLASTIC NAMEPLATES, WHITE WITH BLACK CENTER CORE, MINIMUM SIZE 1 BY 2.5 INCHES. ENGRAVE INTO THE CORE MINIMUM ¼”
NORMAL BLOCK STYLE LETTERING.
20. LABEL BACK SIDE OF COVER PLATES OF RECEPTACLES WITH THE CIRCUIT NUMBER SERVING THE DEVICE. PERMANENTLY MARK JUNCTION BOXES WITH CIRCUIT NUMBERS ON THE OUTSIDE OF THE BOX WHEN
ABOVE CEILING AND LABEL ON THE INSIDE OF THE BOX WHEN CONCEALED IN WALL. CONDUIT CONTAINING CIRCUITS FOR THE EMERGENCY SYSTEM SHALL BE MARKED ACCORDINGLY.
21. CONDUIT STUB-UPS FOR SPECIAL SYSTEMS AND OTHER EQUIPMENT MUST HAVE ROUNDED PROTECTIVE BUSHINGS AT THE TOP OF CONDUIT. PROVIDE PULL WIRES IN EMPTY CONDUIT RESERVED FOR FUTURE
INSTALLATION.
22. WHERE TRANSFORMERS HAVE IMPEDANCES SPECIFIED, THE INTERRUPTING CAPACITY OF THE DOWNSTREAM EQUIPMENT HAS BEEN CALCULATED ACCORDINGLY. IF THE MANUFACTURER HAS PROVIDED A
TRANSFORMER OUTSIDE OF NORMAL IMPEDANCE TOLERANCES (+/- 7.5%), THE DOWNSTREAM EQUIPMENT MAY NOT HAVE SUFFICIENT INTERRUPTING CAPACITY. CONTACT THE ARCHITECT BEFORE
PROCEEDING WITH WORK ON THE AFFECTED EQUIPMENT.
23. PROVIDE PULL-BOXES, SUPPORTS, HANGERS AND OTHER NECESSARY ACCESSORIES FOR A COMPLETE INSTALLATION. ADJUST WIRING SIZES AND PROTECTIVE DEVICES AS NECESSARY TO SUPPORT THE
REQUIREMENTS OF THE SUPPLIED EQUIPMENT. IF THE SUPPLIED EQUIPMENT DIFFERS FROM THE BASIS OF DESIGN, PROVIDE REVISED WIRING AND PROTECTIVE DEVICES AT NO ADDITIONAL COST.
24. CONDUIT MUST BE CONCEALED IN FINISHED SPACES, UNLESS NOTED OTHERWISE. CONDUIT MAY BE EXPOSED IN EXISTING SPACES, UNLESS NOTED OTHERWISE. CONDUIT MUST BE CONCEALED ON EXTERIOR
WALLS UNLESS OTHERWISE EXPRESSLY PERMITTED BY THE ARCHITECT.
25. COORDINATE WITH THE ARCHITECT COLOR SELECTIONS OF COVER PLATES; RECEPTACLE BODIES; SWITCH BODIES; AND ELECTRICAL EQUIPMENT IN FINISHED SPACES.
26. UPDATE CIRCUIT DIRECTORIES AFFECTED BY THIS PROJECT WITH TYPED ENTRIES. HAND LETTERING IS UNACCEPTABLE.
27. MINIMUM WIRING IS #12 AWG CU WITH THHN/THWN-2 INSULATION IN 3/4” TRADE SIZE CONDUIT, UNLESS NOTED OTHERWISE. TYPE MC CABLE MAYBE USED WITH PRIOR WRITTEN APPROVAL OF THE ARCHITECT IF
THE COST SAVINGS ARE JUSTIFIED.
28. PATCH AND REPAIR PENETRATIONS REQUIRED BY THE WORK. WIRING PENETRATIONS THROUGH FIRE RATED WALLS & FLOORS SHALL UTILIZE UL APPROVED FIRESTOP SEALANT AT FIREWALL PENETRATIONS IN
ACCORDANCE WITH APPLICABLE UL ASSEMBLIES. IF A PRODUCT DOES NOT HAVE A UL LISTED SYSTEMS DESIGN TO COVER A SPECIFIC APPLICATION, THE PRODUCT CANNOT BE USED FOR THAT APPLICATION.
29. DO NOT CUT STRUCTURAL ELEMENTS WITHOUT PRIOR APPROVAL OF THE ARCHITECT.
30. WIRE-PULLING COMPOUNDS SHALL BE UL 267 LISTED.
31. MULTIWIRE CIRCUITS (SHARED NEUTRALS) ARE NOT PERMITTED.
32. PROVIDE EXPANSION JOINT FITTINGS AT EXPANSION JOINTS AND SECURE AT BOTH ENDS OF THE JOINT.
33. LOW VOLTAGE WIRING NOT RUN IN CABLE TRAY MUST BE SUPPORTED BY J-HOOKS MOUNTED ON WALLS ABOVE THE CEILING OR SUSPENDED FROM STRUCTURE. PROVIDE J-HOOK SUPPORTS MIN 3 FT OC.
ELECTRICAL ABBREVIATIONS:
A
A AMPERE
AC ALTERNATING CURRENT
ACB AIR CIRCUIT BREAKER
ACS ACCESS CONTROL SYSTEM
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADJ ADJACENT
AF AMPERE FRAME
AFC AVAILABLE FAULT CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AIC AMPERES INTERRUPTING
CAPACITY, SYMMETRICAL
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECT/ARCHITECTURAL
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
B
BKBD BACKBOARD
BKR BREAKER
BLDG BUILDING
BMS BALANCED MAGNETIC SWITCH
BSMT BASEMENT
C
C CONDUIT
CAB CABINET
CAT 6 4 PAIR, CATEGORY 6 UTP CABLE
CATV COMMUNITY ANTENNA TELEVISION
CB CIRCUIT BREAKER
CCT CIRCUIT
CCTV CLOSED CIRCUIT TELEVISION
CD CABLE DUCT/CANDELA
CER COMMUNICATIONS
EQUIPMENT ROOM
CFCI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CFL COMPACT FLUORESCENT
CLG CEILING
CLR CLEAR
CMH COMMUNICATIONS
MAINTENANCE HOLE
CNTL CONTROL
COL COLUMN
COMM COMMUNICATIONS
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CP CONTROL PANEL
CR CONTROL
CT CURRENT TRANSFORMER
CTR CENTER
CU COPPER
D
D DEPTH/DIMMER
DB DECIBEL
DBL DOUBLE
DEG DEGREE
DEMARC DEMARCATION
DEMO DEMOLITION
DEPT DEPARTMENT
DE DETAIL
DIA DIAMETER
DIM DIMENSION
DIST DISTRIBUTION
DS DISCONNECT SWITCH
DWG DRAWING
E
E EAST
EES EARTH ELECTRODE SYSTEM
EF ENTRANCE FACILITY
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EMT ELECTRICAL METALLIC TUBING
ENGR ENGINEER
EO ELECTRICALLY OPERATED
EPO EMERGENCY POWER OFF
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
EXIST EXISTING
EXT EXTERIOR
F
FA FIRE ALARM
FCU FAN COIL UNIT
FLR FLOOR
FMC FLEXIBLE METAL CONDUIT
FOC FIBER OPTIC CABLE
FS FLOW SWITCH
FT FEET/FOOT
FU FUSE
FV FIELD VERIFY
G
GA GAUGE
GALV GALVANIZED
GEN GENERATOR/GENERAL
GF GROUND FAULT
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GND GROUND
H
HH HAND HOLE
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC SWITCH
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HR HOUR
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
IC INTERMEDIATE CROSS-CONNECT
IDC INSULATION DISPLACEMENT
CONNECTOR
IDF INTERMEDIATE DISTRIBUTION FRAME
IDS INTRUSION DETECTION SYSTEM
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IN INCH/INCHES
INST INSTANTANEOUS
J
J-BOX JUNCTION BOX
K
KA KILOAMPERE
KAIC THOUSAND AMPERES
INTERRUPTING CAPACITY
SYMMETRICAL
KCMIL THOUSAND CIRCULAR MILLS
KS KEY SWITCH
KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
L
L LENGTH
LA LIGHTNING ARRESTER
LAN LOCAL AREA NETWORK
LBS POUND/POUNDS
LED LIGHT-EMITTING DIODE
LF LINEAR FEET/LINEAR FOOT
LFMC LIQUID-TIGHT FLEXIBLE
METAL CONDUIT
LTG LIGHTING
M
M METER
MAINT MAINTENANCE
MAX MAXIMUM
MC METAL-CLAD CABLE
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MECH MECHANICAL
MEZZ MEZZANINE
MFD MANUFACTURED
MFR MANUFACTURER
MH METAL HALIDE/MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MM MULTIMODE FIBER
MMS MANUAL MOTOR STARTER
MOCP MAXIMUM OVERCURRENT
PROTECTION
MTD MOUNTED
MTR MOTOR
MTS MANUAL TRANSFER SWITCH
N
N NORTH
NA NOT APPLICABLE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NESC NATIONAL ELECTRICAL SAFETY CODE
NEU NEUTRAL
NF NON-FUSED
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER/NORMALLY OPEN
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER/OVERCURRENT
OD OUTSIDE DIAMETER
OH OVERHEAD
OPER OPERATOR
OPT OPTIONAL
OSP OUTSIDE PLANT
OZ OUNCE/OUNCES
P
P POLE
PB PUSHBUTTON/PULLBOX
PC PHOTOELECTRIC CELL
PCU PREMISE CONTROL UNIT
PF POWER FACTOR
PH PHASE
PN PART NUMBER
PNL PANEL
PNLBRD PANELBOARD
PR PAIR
PT POINT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POTENTIAL TRANSFORMER
PTZ PAN, TILT, ZOOM
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
Q
Q QUANTITY
R
R RADIUS
REF REFERENCE
REQD REQUIRED
RCP REFLECTED CEILING PLAN
RFI REQUEST FOR INTERPRETATION
RGS GALVANIZED STEEL RMC
RM ROOM
RMC RIGID METAL CONDUIT
RTU ROOF TOP UNIT
RU RACK UNIT
S
S SOUTH
SA SURGE ARRESTER
SC SPLIT CIRCUIT
SCHED SCHEDULE/SCHEDULED
SCTP SCREENED TWISTED PAIR
SF SQUARE FOOT/SQUARE FEET
SHFT SHAFT
SHLD SHIELDED
SIM SIMILAR
SM SINGLE MODE FIBER
SPD SURGE PROTECTIVE DEVICE
SPEC SPECIFICATION
SQIN SQUARE INCH
STD STANDARD
STP SHIELDED TWISTED PAIR
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
T
TB TERMINAL BOARD
TC TERMINAL CABINET
TD TIME DELAY
TEL TELEPHONE
TEMP TEMPORARY
TGB TELECOMMUNICATIONS
GROUNDING BUSBAR
THK THICKNESS/THICK
THRU THROUGH
TMGB TELECOMMUNICATIONS
MAIN GROUNDING BUSBAR
TR TELECOMMUNICATIONS ROOM
TV TELEVISION
TYP TYPICAL
U
UC UNDER COUNTER
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTABLE POWER SUPPLY
UTIL UTILITY
UTP UNSHIELDED TWISTED PAIR
V
V VOLT
VAR VARIES
VCB VACUUM CIRCUIT BREAKER
VER VERIFY
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W
W WEST/WIRE/WATT/WIDTH
W/ WITH
W/O WITHOUT
WP WATERPROOF
WT WEIGHT
X
XFMR TRANSFORMER
XP EXPLOSION PROOF
N O
T
FO
R
CONST RUCT ION
NOT FOR CONST
R U C
T I O
N
R E V
IE
W
S ET
REV
IEW
S
ET
THIS
DOCUMENT IS
PRELIMINARY IN
NATURE AND IS NOT
A FINAL, SIGNED
AND SEALED
DOCUMENT
920 W. Main
Oklahoma City, Oklahoma 73106 phone: 405.232.5700 web: www.adgokc.com
ADG
CA: #6447 Exp. 6/18
DESIGNED
WORK ORDER NO.
DRAWN
ISSUED BY OFFICE OF: DATE:
PREPARED BY
REV DATE
APPROVED BY
DESCRIPTION APP'DCHECK
OF2014-014040
REVIEWED BY
DRAWING NO.
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FACILITY MANAGEMENT
AMP-400
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SMALL ARCHITECTS MARK McDANIEL
SENSITIVE SECURITY INFORMATION WARNING:
This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S.
government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
E0.00
ELECTRICAL LEGENDS, ABBREVIATIONS, AND INDEX
MAY 11, 2017MJN
RJV
MJN
009-H08 & 010-H09
HANGARS 8 & 9
MECHANICAL UPGRADES
SHEET INDEX
009-H08
E0.00 ELECTRICAL LEGENDS, ABBREVIATIONS, AND INDEX
E2.01 HANGAR 8 ELECTRICAL FIRST FLOOR PLAN
E2.03 HANGAR 8 ELECTRICAL THIRD FLOOR PLAN
E2.08 HANGAR 8 ELECTRICAL ROOF PLAN
E5.01 FEEDER SCHEDULE
E6.01 HANGAR 8 PANELBOARD SCHEDULES
E6.02 HANGAR 8 PANELBOARD SCHEDULES
E6.03 HANGAR 8 PANELBOARD SCHEDULES
010-H09
E2.10 HANGAR 9 FIRST FLOOR POWER PLAN
E2.11 HANGAR 9 SWITCHGEAR INFORMATION
E2.20 HANGAR 9 PENTHOUSE TO ROOF ELECTRICAL PLAN
E4.10 HANGAR 9 ELECTRICAL ROOF PLAN
E6.10 HANGAR 9 PANELBOARD SCHEDULES
1 8/14/2017 Addendum #2 MJN MJN
| Sheets |
| E0.00 - ELECTRICAL LEGENDS, ABBREVIATIONS, AND INDEX |
File details come from the government source that posted it. Updated .