Drawings - TV System Upgrade - 553-22-209.pdf
PDF 23 MB Posted
- Attached to
- Z1DA-Upgrade TV System IFB 553-22-209 Amendment 003 Federal contract opportunity
- Solicitation number
- 36C25026B0031
About this file
This is a set of electrical construction drawings for the John D. Dingell VA Medical Center's TV System Upgrade project (553-22-209) in Detroit, Michigan, dated April 26, 2024, in final bid documents phase. The drawings specify the upgrade of the medical center's television system from analog to digital across multiple floors and buildings.
The project scope includes installation of new TV outlets, coaxial connections, data cabling (CAT6A Ethernet), and fiber optic infrastructure throughout the facility. Key technical requirements include: providing duplex receptacles for new TVs at 84" mounting height (unless noted otherwise); installing combination data/coax outlets at 4" boxes; running RG6 coaxial cable and CAT6A cables from outlets to telecommunications rooms or cable trays; installing new wall-mounted equipment racks in electrical closets on multiple floors with 48-port CAT6A patch panels and 6-port fiber switches; and establishing a new fiber optic riser system with OM3 multimode 50/125 micron aqua-jacketed cable connecting from LL210 demarc room throughout the building. The project mandates all work comply with NEC standards, includes firestopping of penetrations with Hilti FS-ONE sealant, requires coordination with the Contracting Officer's Representative (C.O.R.) for all construction activities, and specifies that all electrical and mechanical work be performed by licensed personnel. General notes emphasize protection of existing systems, maintenance of exit routes during construction, coordination with all trades, and strict adherence to ICRA control measures and existing facility protocols. The drawings encompass lower level through eighth floor coverage across multiple zones with detailed electrical plans, conduit routing specifications, and material requirements for the complete digital TV network infrastructure installation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25026B0031 0003.docx | DOCX document | |
| S06 36C25026B0031 0002 - 553-22-209.pdf | ||
| S06 RFI Repsonses 1 - 553-22-209.pdf | ||
| S06 RFI Repsonses 3 - 553-22-209.pdf.pdf | ||
| S06 RFI Repsonses 2 - 553-22-209.pdf | ||
| 36C25026B0031 0002.docx | DOCX document | |
| S04 - Pre Bid Site Visit Attendance Log - 553-22-209.pdf | ||
| 36C25026B0031 0001.docx | DOCX document | |
| ATTACHMENT VAAR 852.219-75 DEVIATION Jan 2023 LIMITATIONS OF SUBCONTRACTING COMPLIANCE CERTIFICATION.pdf | ||
| S02 36C25026B0031 - Upgrade TV System Network - 553-22-209.pdf | ||
| RFI Form - 553-22-209.doc | DOC document | |
| Contractor EMR Certification Form - 553-22-209.docx | DOCX document | |
| Specs - TV System Upgrade - 553-22-209.pdf | ||
| Wage Determination - MI20260101 01-02-2026 - 553-22-209.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE LOCATION
JOHN D. DINGELL VA MEDICAL CENTER
#553-22-209
DEPARTMENT OF VETERANS AFFAIRS
4646 JOHN R. STREET DETROIT, MICHIGAN 48201
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
GENERAL NOTES
1. SEE GENERAL PROJECT NOTES FOR NEW WORK FOR ADDITIONAL REQUIREMENTS FOR WORK WITHIN THE
EXISTING FACILITY.
2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO
DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL CAREFULLY
EXAMINE EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE
IMMEDIATE ATTENTION OF THE ARCHITECT.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING
DEMOLITION AND CONSTRUCTION.
4. MAINTAIN EXIT EGRESS PATHS TO EXISTING EXIT DOORS DURING CONSTRUCTION.
5. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE
AREAS OF WORK AND THE ROUTES MUST BE RETURNED TO THEIR ORIGINAL CONDITION AT THE END OF
THE PROJECT.
6. ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH THE C.O.R. TO MINIMIZE
DISRUPTIONS OF NORMAL FUNCTIONS OF THE VA'S OCCUPIED AREAS.
7. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE C.O.R. FOR THE
SCHEDULED TIME OF THE CONSTRUCTION ACTIVITIES. NO WORK SHALL BE DONE WITHOUT THE WRITTEN
APPROVAL OF THE C.O.R. THE C.O.R. RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT
ANY TIME. NO RADIOS SHALL BE PERMITTED AT ANY TIME IN WORK AREAS ADJACENT TO OCCUPIED
SPACES.
8. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO AREAS THAT ARE IN OPERATION AND
SERVED BY THEM. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES
WITH C.O.R. NO SHUT DOWN OF EXISTING SERVICES IS ALLOWED TO OCCUR UNTIL RECEIVING THE
C.O.R.'S WRITTEN APPROVAL OF THE SHUT DOWN SCHEDULE. PROVIDE TEMPORARY SERVICES AND/OR
UTILITIES DURING INTERRUPTIONS AS REQUIRED AND APPROVED BY THE C.O.R.
9. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO THE V.A.'S
AREAS ADJACENT TO NEW CONSTRUCTION OR AREAS WHERE VARIOUS SYSTEM CONNECTIONS OR
EXTENSIONS ARE REQUIRED. IN THESE AREAS, THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE
CAUSED BY LACK OF SUFFICIENT PROTECTION FROM THE WEATHER AND FROM THE RESULTS OF ALL
CONSTRUCTION ACTIVITY INCLUDING DUST AND WATER.
10. THE CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM THE C.O.R. BEFORE USING OPEN FLAMES, WELDING RODS AND TORCHES. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS TO
PROHIBIT THE MIGRATION OF SMOKE AND OTHER PRODUCTS OF COMBUSTION INTO OCCUPIED AREAS OF
THE EXISTING BUILDING AND FOR OBTAINING ALL REQUIRED PERMITS RELATED TO HOT WORK.
11. DO NOT OVERLOAD THE EXISTING BUILDING STRUCTURE. MAINTAIN THE STRUCTURAL INTEGRITY OF ALL
STRUCTURAL FRAMING MEMBERS AND SYSTEMS AT ALL TIMES.
12. ALL DEMOLISHED MATERIAL, EXCEPT MATERIAL THAT IS LISTED OR MARKED FOR RETENTION, SHALL
BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE DISPOSED OF. NO DEBRIS RESULTING
FROM WORK SHALL BE LEFT IN THE CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK.
13. REMOVAL OF A PARTICULAR ITEM IS TO INCLUDE ALL RELATED ITEMS, SUCH AS REMOVAL OF WALLS
WOULD INCLUDE ASSOCIATED DOORS, HARDWARE, ELECTRICAL, PLUMBING, MECHANICAL. REFER TO
DEMOLITION DRAWINGS FOR MORE INFORMATION. FOR ALL REMOVALS, THE GENERAL CONTRACTOR
SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING MECHANICAL, ELECTRICAL AND PLUMBING.
14. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED
AS REQUIRED UNTIL PERMANENT SUPPORT IS PROVIDED IN THE FINAL CONSTRUCTION.
15. ALL OPENINGS IN EXISTING WALLS, CEILINGS AND FLOORS, WHICH ARE THE RESULT OF REMOVALS AND
OTHER NEW CONSTRUCTION ACTIVITY, SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE
EXISTING MATERIALS OR AS NOTED ON DRAWINGS. IF THE PATCH IS TO BE MADE IN FIRE RATED
CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED
TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
16. ALL EXISTING OPENINGS IN CEILINGS, FLOORS AND WALLS DISCOVERED IN THE EXISTING STRUCTURE
SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO
BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE
PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
17. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE
ATTACHMENT OR APPLICATION OF NEW MATERIALS OR CONSTRUCTION, PREPARE OR ALTER THE
EXISTING SURFACES AS NECESSARY TO PROPERLY ACCOMMODATE THE NEW MATERIALS.
18. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES THAT IMPACT THE NEW WORK.
DETERMINE THE SIZE AND LOCATION THE PENETRATIONS FROM THE EXISTING UTILITIES WITHIN THE NEW
WORK. SEAL TIGHT TO ALL PENETRATIONS AND CAULK.
19. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE
SAFE'D TO ACHIEVE THE REQUIRED FIRE RATING BY THE END OF CONSTRUCTION OPERATIONS FOR EACH
DAY.
20. NEW HOLES IN EXISTING ROOF STRUCTURES FOR NEW WORK MUST BE COORDINATED WITH THE
EXISTING STRUCTURE SO THAT CRITICAL STRUCTURAL MEMBERS ARE NOT DAMAGED.
21. UNLESS OTHERWISE NOTED, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING
SALVAGED STOCK BEFORE ORDERING NEW MATERIAL.
22.
EXISTING FACILITIES:
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL AUTHORITIES, CODES, RULES AND REGULATIONS.
2. THESE DOCUMENTS SHOW THE MINIMUM CONSTRUCTION REQUIREMENTS AND THE MINIMUM QUALITY OF
WORK EXPECTED. MORE STRINGENT REQUIREMENTS STIPULATED WITHIN RELEVANT MANUFACTURER’S
INSTALLATION INSTRUCTIONS WILL SUPERSEDE.
3. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE C.O.R. PRIOR TO PROCEEDING
WITH WORK.
4. ANY CONFLICTS WITHIN THE DRAWINGS, BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, OR
BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS AT THE SITE, ARE TO BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE C.O.R. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL
WRITTEN CLARIFICATION FROM THE ARCHITECT IS RECEIVED.
5. UNLESS OTHERWISE NOTED, ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED PER THE APPLICABLE
PROVISIONS OF THESE DOCUMENTS AND THE MANUFACTURER’S INSTRUCTIONS.
6. ALL MATERIALS USED SHALL BE NEW UNLESS OTHERWISE NOTED AND/OR OF A QUALITY TO MEET OR
EXCEED ALL APPLICABLE INDUSTRY STANDARDS. WHERE SPECIFIED PRODUCTS OR MANUFACTURERS
ARE NOT NOTED, THE CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT TO OBTAIN A MINIMUM
STANDARD OF QUALITY.
7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR
CONSTRUCTION.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB-SITE SAFETY INCLUDING BUT NOT LIMITED TO THE
ADHERENCE TO OSHA REGULATIONS.
9. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY PERSONNEL LICENSED IN THE STATE
WHERE THIS PROJECT IS LOCATED.
10. REMOVE ALL DEBRIS PROPERLY FROM THE SITE. LOAD DEBRIS DIRECTLY ONTO TRUCKS OR INTO VA
PROVIDED DUMPSTERS FOR REMOVAL. DISPOSE OF DEBRIS LEGALLY. DO NOT BURN DEBRIS ON THE
SITE. DO NOT ALLOW DEBRIS TO ENTER SEWERS. DO NOT ALLOW PILED DEBRIS TO ENDANGER
STRUCTURES, BLOCK EXISTS OR ROADWAYS. COMBUSTIBLE WASTE WHICH COULD CREATE A FIRE
HAZARD SHALL NOT BE PERMITTED TO ACCUMULATE IN OR AROUND THE CONSTRUCTION SITE.
11. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINES, INCLUDING, BUT NOT LIMITED TO MECHANICAL, ELECTRICAL, PLUMBING & SITE DRAWINGS. EXACT SIZE AND LOCATION OF ALL ROOF AND FLOOR
OPENINGS SHOWN ON ARCHITECTURAL DRAWINGS SHALL BE VERIFIED WITH THE ASSOCIATED SUB-
CONTRACTORS PRIOR TO CONSTRUCTION.
12. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. ALL PLAN DIMENSIONS ARE TAKEN TO FINISH
FACE OF CONSTRUCTION.
13. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED.
14. THE CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING BUT NOT LIMITED TO
MECHANICAL, ELECTRICAL, AND PLUMBING. SEAL CONSTRUCTION TIGHT TO ALL PENETRATIONS AND
CAULK.
15. ALL PENETRATIONS THROUGH FIRE RATED CONSTRUCTION MUST BE FIRE SAFE'D IN ACCORDANCE WITH
THE SPECIFICATIONS. IF FLOOR OR RATED WALL PENETRATIONS CANNOT BE FIRESTOPPED AT THE END
OF THE WORK SHIFT DUE TO THE NEED TO PULL ADDITIONAL CABLES, TEMPORARY FIRESTOPPING
COMPOSED OF MINERAL WOOL SHOULD BE INSTALLED IN THE PENETRATION TO PROVIDE PROTECTION
AGAINST FIRE/SMOKE SPREAD THROUGH THE UNSEALED PENETRATION.
16. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VERIFYING
ALL REQUIRED ROUGH OPENINGS, AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER, C.O.R. PRIOR TO CONSTRUCTION.
NEW WORK:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e T
V S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e T
V S y s te m
A R
C H rv t
/2
/2
:3
:5
P
M
100-GI000
COVER SHEET
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTSJOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e T
V S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e T
V S y s te m
A R
C H rv t
/2
/2
:3
:5
P
M
100-GI000
COVER SHEET
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTSJOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
NTS
VICINITY MAP
N
NTS
VA CAMPUS SITE MAP
DIRECTOR, MEDICAL CENTER
CHRISTOPHER CAULEY
ASSOCIATE DIRECTOR, MEDICAL CENTER
MICHELLE WERNER
CHIEF, FACILITIES MANAGEMENT SERVICES
CASEY P. THAYER
ASSOCIATE CHIEF, FACILITY MANAGEMENT SERVICES
ROBERT PETERS
CHIEF, PASS
GEORGE CHESTER
CHIEF SAFETY
JEFF EDGE
CHIEF, PUBLIC AFFAIRS
BILL BROWNING
S H E E T I N D E X
SHEET
NUMBER SHEET NAME
GENERAL
100-GI000 COVER SHEET
ELECTRICAL
100-EE001 ELECTRICAL LEGEND
100-EE100 ELECTRICAL PLAN - LOWER LEVEL FLOOR OVERALL
100-EE101 ELECTRICAL PLAN - FIRST FLOOR OVERALL
100-EE102 ELECTRICAL PLAN - SECOND FLOOR OVERALL
100-EE103 ELECTRICAL PLAN - THIRD FLOOR OVERALL
100-EE104 ELECTRICAL PLAN - FOURTH FLOOR OVERALL
100-EE105 ELECTRICAL PLAN - FIFTH FLOOR OVERALL
100-EE106 ELECTRICAL PLAN - SIXTH FLOOR OVERALL
100-EE107 ELECTRICAL PLAN - SEVENTH FLOOR OVERALL
100-EE108 ELECTRICAL PLAN - EIGHTH FLOOR OVERALL
100-ET100.01 LOWER LEVEL ELECTRICAL PLAN - ZONE 1
100-ET100.02 LOWER LEVEL ELECTRICAL PLAN - ZONE 2
100-ET100.03 LOWER LEVEL ELECTRICAL PLAN - ZONE 3
100-ET100.04 LOWER LEVEL ELECTRICAL PLAN - ZONE 4
100-ET100.05 LOWER LEVEL ELECTRICAL PLAN - ZONE 5
100-ET100.06 LOWER LEVEL ELECTRICAL PLAN - ZONE 6
100-ET100.07 LOWER LEVEL ELECTRICAL PLAN - ZONE 7
100-ET100.08 LOWER LEVEL ELECTRICAL PLAN - ZONE 8
100-ET100.09 LOWER LEVEL ELECTRICAL PLAN - ZONE 9, 10 & ENERGY CENTER 13
100-ET101.01 FIRST FLOOR ELECTRICAL PLAN - ZONE 1
100-ET101.02 FIRST FLOOR ELECTRICAL PLAN - ZONE 2
100-ET101.03 FIRST FLOOR ELECTRICAL PLAN - ZONE 3
100-ET101.04 FIRST FLOOR ELECTRICAL PLAN - ZONE 4
100-ET101.05 FIRST FLOOR ELECTRICAL PLAN - ZONE 5
100-ET101.06 FIRST FLOOR ELECTRICAL PLAN - ZONE 6
100-ET101.07 FIRST FLOOR ELECTRICAL PLAN - ZONE 7
100-ET101.08 FIRST FLOOR ELECTRICAL PLAN - ZONE 8
100-ET101.11 FIRST FLOOR ELECTRICAL PLAN - ZONE 11
100-ET101.13 FIRST FLOOR ENERGY CENTER ELECTRICAL PLAN - ZONE 13
100-ET101.13i SECOND FLOOR ENERGY CENTER ELECTRICAL PLAN - ZONE 13
100-ET102.01 SECOND FLOOR ELECTRICAL PLAN - ZONE 1
100-ET102.02 SECOND FLOOR ELECTRICAL PLAN - ZONE 2
100-ET102.04 SECOND FLOOR ELECTRICAL PLAN - ZONE 4
100-ET102.05 SECOND FLOOR ELECTRICAL PLAN - ZONE 5
100-ET102.06 SECOND FLOOR ELECTRICAL PLAN - ZONE 6
100-ET102.07 SECOND FLOOR ELECTRICAL PLAN - ZONE 7
100-ET102.08 SECOND FLOOR ELECTRICAL PLAN - ZONE 8
100-ET103.01 THIRD FLOOR ELECTRICAL PLAN - ZONE 1
100-ET103.02 THIRD FLOOR ELECTRICAL PLAN - ZONE 2
100-ET103.03 THIRD FLOOR ELECTRICAL PLAN - ZONE 3
100-ET103.04 THIRD FLOOR ELECTRICAL PLAN - ZONE 4
100-ET103.05 THIRD FLOOR ELECTRICAL PLAN - ZONE 5
100-ET103.06 THIRD FLOOR ELECTRICAL PLAN - ZONE 6
100-ET103.07 THIRD FLOOR ELECTRICAL PLAN - ZONE 7
100-ET103.08 THIRD FLOOR ELECTRICAL PLAN - ZONE 8
100-ET104.01 FOURTH FLOOR ELECTRICAL PLAN - ZONE 1
100-ET104.02 FOURTH FLOOR ELECTRICAL PLAN - ZONE 2
100-ET104.05 FOURTH FLOOR ELECTRICAL PLAN - ZONE 5
100-ET104.06 FOURTH FLOOR ELECTRICAL PLAN - ZONE 6
100-ET105.01 FIFTH FLOOR ELECTRICAL PLAN - ZONE 1
100-ET105.02 FIFTH FLOOR ELECTRICAL PLAN - ZONE 2
100-ET105.03 FIFTH FLOOR ELECTRICAL PLAN - ZONE 3
100-ET105.04 FIFTH FLOOR ELECTRICAL PLAN - ZONE 4
100-ET105.05 FIFTH FLOOR ELECTRICAL PLAN - ZONE 5
100-ET106.01 SIXTH FLOOR ELECTRICAL PLAN - ZONE 1
100-ET106.02 SIXTH FLOOR ELECTRICAL PLAN - ZONE 2
100-ET107.01 SEVENTH FLOOR ELECTRICAL PLAN - ZONE 1
100-EE600 NEW FIBER OPTIC CABLE RISER DIAGRAM
100-EE601 CONDUIT AND WIRE MANAGEMENT DETAILS
CONSTRUCTION COR
JAMES MANUELSON
No. Revisions: Date:
DESIGN DEVELOPMENT 65% 12/01/2023
CONSTRUCTION DOCUMENT 95% 02/05/2024
CONSTRUCTION BID DOCUMENTS 03/26/2024
FINAL BID DOCUMENTS 04/26/2024
No. Revisions: Date:
DESIGN DEVELOPMENT 65% 12/01/2023
CONSTRUCTION DOCUMENT 95% 02/05/2024
CONSTRUCTION BID DOCUMENTS 03/26/2024
FINAL BID DOCUMENTS 04/26/2024
03/26/2024
AUDIOVISUAL PRODUCTION SPECIALIST
STEPHEN DOYLE
PANIC BUTTON
HANDICAP DOOR MOTOR
HANDICAP DOOR OPERATOR
ELECTRIC LATCH
SECURITY CAMERA CCTV - DOME
DURESS/PANIC ALARM
PILOT LIGHT / CHIME
PUSHBUTTON
MD MOTION DETECTOR
CC
EL
AP
X
PB
K
HD
HA
PP
WIRELESS ACCESS POINT
KEY PAD
KEY PAD / CARD READER
SECURITY / ACCESS CONTROL POWER
GROUNDING
WIRING ABBREVIATIONS
FLUSH FLOOR MOUNTED NEMA 5-20 DUPLEX RECEPTACLE
UNLESS NOTED OTHERWISE
FLUSH FLOOR MOUNTED NEMA 5-20 QUAD RECEPTACLE
UNLESS NOTED OTHERWISE
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
SUBSCRIPT: WP - WEATHERPROOF, GF - GROUND FAULT CIRCUIT
INTERRUPTER
NEMA 5-20 DOUBLE DUPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 44" AFF
UNLESS NOTED OTHERWISE
RECEPTACLE, (NEMA CONFIGURATION AS NOTED)
NEMA 5-20 DUPLEX RECEPTACLE WITH USB CHARGER MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 DUPLEX SPLIT RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 SIMPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
JUNCTION BOX
POWER CONNECTION
MOTOR
NON-FUSED DISCONNECT SWITCH. SIZE AS SHOWN
FUSED DISCONNECT SWITCH. SIZE FUSES FOR EQUIPMENT
BASED ON MANUFACTURERS RECOMMENDATIONS
COMBINATION STARTER
SURFACE MOUNTED PANELBOARD OR AUTOMATIC TRANSFER
SWITCH AS INDICATED.
(E) INDICATES EXISTING PANELBOARD
RECESSED MOUNTED PANELBOARD
(E) INDICATES EXISTING PANELBOARD
UNDERGROUND
CONCEALED OR OPEN
FLEXIBLE CONDUIT CONNECTION
WP/GF
6-30R
J
AIR TERMINAL
GROUNDING ROD
STATIC GROUNDING RECEPTACLE
CONNECTION TO GROUND
GRID COUNTERPOISE CONDUCTOR
LIGHTNING PROTECTION ROOF CONDUCTOR
LIGHTNING PROTECTION DOWN CONDUCTOR
G
RC
DC
A AMPERE
AC ABOVE COUNTER, 42"AFF UNLESS OTHERWISE INDICATED
ADA MERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR - TO BOTTOM
AL ALUMINUM
1/C ONE CONDUCTOR
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CU COPPER
EX, (E) EXISTING
EF EXHAUST FAN
EMT ELECTRICAL METALLIC TUBING
EWC ELECTRIC WATER COOLER
FACP FIRE ALARM CONTROL PANEL
FM FREQUENCY MODULATION
GE GROUND EQUILIZER
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTION
HACR HEATING AIR CONDITIONING REFRIGERATION
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HT HEIGHT
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
JB JUNCTION BOX
KWH KILOWATT HOUR
LED LIGHT EMITTING DIODE
MCB MAIN CIRCUIT BREAKER
MH MOUNTING HEIGHT - TO CENTER
MLO MAIN LUGS ONLY
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NF NON FUSED
NO. NUMBER
OS OCCUPANCY SENSOR
PB PULL BOX
PH PHASE
PIR PASSIVE INFRARED
RGS RIGID GALVANIZED STEEL
SM SINGLE MODE
SPD SURGE PROTECTIVE DEVICE
TGB TELECOMMUNICATIONS GROUNDING BAR
TMGB TELECOMMUNICATIONS MAIN GROUNDING BAR
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
UNO UNLESS NOTED OTHERWISE
V VOLT
VA VOLTAMPERE
VVD VARIABLE VOLUME DAMPER
W WATTS
WP WEATHERPROOF
XFMR TRANSFORMER
CR
DOOR CONTACTDC
DATA/TELEPHONE
DUAL DATA/TELEPHONE OUTLET. PROVIDE (2) CAT 6A CABLES WITHIN
CONDUIT OR OTHER APPROVED RACEWAY FROM OUTLET TO
NEAREST TELECOMMUNICATIONS ROOM OR CABLE TRAY.
D
AP WIRELESS ACCESS POINT - CEILING MOUNT
TV COAX OUTLET. RG6 COAXIAL CABLE FROM OUTLET TO NEAREST
TELECOMMUNICATIONS ROOM OR CABLE TRAY. 84" MH UNLESS
OTHER WISE NOTED.
TV
COMBINATION DATA/COAX OUTLET. 4" BOX. PROVIDE (1) CAT6A CABLE
AND (1) RG6 COAXIAL CABLE CONNECTOR FROM OUTLET TO NEAREST
TELECOMMUNICATIONS ROOM OR CABLE TRAY. 84" MH UNLESS
OTHERWISE NOTED.
C
DATA/TELEPHONE OUTLET. PROVIDE (1) CAT 6A CABLE WITHIN
CONDUIT OR OTHER APPROVED RACEWAY FROM OUTLET TO
NEAREST TELECOMMUNICATIONS ROOM OR CABLE TRAY.
D
A ALL CONDUCTORS WILL BE COPPER IN CONDUIT.
B ALL WORK WILL BE DONE IN ACCORDANCE WITH THE NEC FOR A COMPLETE AND OPERATIONAL INSTALLATION.
C PROVIDE A SEPARATE NEUTRAL CONDUCTOR WITH EACH 20A-120V POWER CIRCUIT - GROUND TOTAL SYSTEM PER NEC 250.
D ALL 20A-120V POWER CIRCUITS SHALL CONSIST OF #12 AWG CONDUCTORS UNLESS INDICATED OTHERWISE.
E ALL EMPTY CONDUITS SHALL BE INSTALLED WITH PULLWIRE PER SPECIFICATIONS.
F PROVIDE PAINT AND FINISH PER SPECIFICATIONS.
G ALL WIRING AND CONDUIT SHALL BE INSTALLED CONCEALED. WHERE WIRING IS REQUIRED TO BE RUN EXPOSED ALONG WALLS AND CEILINGS, IT SHALL BE RUN IN METAL SURFACE RACEWAY MOUNTED TIGHT TO EXISTING SURFACE MATCHING CONTOUR OF BUILDING LINES AND PAINTED (AT ARCHITECTS DIRECTION) TO MATCH SURFACES ON WHICH THEY ARE MOUNTED. COORDINATE ALL LOCATIONS
AND ROUTES WITH THE COR PRIOR TO ROUGH-IN.
H ALL EXTERIOR MOUNTED CONDUIT SHALL BE SEALED WATER AND MOISTURE TIGHT. ALL EXTERIOR MOUNTED DEVICES SHALL BE
WEATHERPROOF NEMA 3R, UNLESS OTHERWISE NOTED.
I PROVIDE NEW CONDUITS TO ALLOW FOR PROPER BENDING RADIUS OF ALL SYSTEMS CABLING AND WIRING INSTALLED UNDER THIS
CONTRACT AS RECOMMENDED BY MANUFACTURERS OF EACH CABLE TYPE.
J CONTRACTOR SHALL RESPECT THE OWNERS PROPERTY AND PROTECT FROM DUST AND DEBRIS THROUGH-OUT THE COMPLETE
PROJECT. PROVIDE DROP CLOTHS, VISQUEEN, ETC... TO ELIMINATE ANY AND ALL MESSES. WORK AREA(S) SHALL BE CLEANED UP PRIOR
TO EACH WORK DAYS COMPLETION.
K STAGGER RECEPTACLES AND OTHER RECESSED OUTLETS WHEN LOCATED ON OPPOSITE SIDES OF PARTITION TO ELIMINATE SOUND TRANSMISSION FROM ONE SPACE TO THE OTHER. CENTER DEVICES WHERE APPLICABLE IN EACH WALL SECTION.
1. WHERE DUPLEX AND ISOLATED GROUND DUPLEX RECEPTACLES ARE LOCATED NEXT TO EACH OTHER ON PLAN, THEY SHALL BE
INSTALLED IN COMMON 2 GANG OUTLET BOX/COVERPLATE ASSEMBLY.
2. NEW OUTLETS INSTALLED IN FURRED OUT WALLS SHALL BE SHALLOW TYPE TO AVOID MASONRY WORK.
L EXACT LOCATION OF ALL DEVICES SERVING EQUIPMENT TO BE VERIFIED AT SITE WITH THE COR PRIOR TO ROUGH-IN.
M COORDINATE EXACT LOCATION AND MOUNTING HEIGHT OF ALL NEW ELECTRICAL DEVICES AND PLYWOOD WITH THE COR PRIOR TO ROUGH-IN.
DEVICES SHALL INCLUDE ALL NEW WORK INDICATED ON THE DRAWINGS; INCLUDING POWER RECEPTACLES, TV
OUTLET, LIGHTING CONTROLS AND SWITCHES, MOTOR CONTROLLERS, AND FA COMPONENTS.
N EXACT LOCATION OF ALL WALL MOUNTED ITEMS (ELECTRIC DEVICES, PANELBOARDS, FIRE ALARM COMPONENTS AND CONTROL PANELS) SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE ENGINEER. SUBMITTAL SHALL BE MADE IN TIMELY FASHION SO
REVIEW MAY BE CONDUCTED PRIOR TO INSTALLATION OF FINISHED WALL SURFACE.
O MOUNT RECEPTACLE OUTLETS AT HEIGHTS AS NOTED ON THE DRAWINGS.
P BRANCH CIRCUIT WIRE SIZING CHART TO BE UTILIZED AS GUIDELINE FOR VOLTAGE DROP COMPENSATION, INCREASE CONDUIT SIZING.
PER WIRE SIZE.
1. 20A-120V CIRCUITS
A #12 WIRE - 60' LENGTH MAX.
B #10 WIRE - 94' LENGTH MAX.
C # 8 WIRE - 137' LENGTH MAX.
D # 6 WIRE - 218' LENGTH MAX.
Q FIRESTOP SEALANT SHALL BE HILTI FS-ONE FOR ALL PENETRATIONS THROUGH FLOORS AND FIRE RATED WALLS.
R ETHERNET CABLE SHALL BE CAT 6A, GREEN JACKET. PUNCH DOWN WITH RJ45 ENDS SET TO T568B.
S FIBER OPTIC CABLE SHALL BE OM3 MULTIMODE (50/125 MICRONS,) AQUA JACKET, WITH QUANTITY OF STRANDS AS NOTED ON THE DRAWINGS.
T ALL WORK EXCEPT DROPS TO OUTLETS SHALL BE COMPLETED IN THE INTERSTITIAL SPACES ABOVE ALL FLOORS, UNLESS DETERMINED
OTHERWISE BY THE COR.
U CONTRACTOR SHALL COMPLY WITH ALL INFECTIOUS CONTROL RISK ASSESSMENT (ICRA) CONTROL MEASURES, INTERIM LIFE SAFETY MEASURES (LSIM), PRE-CONSTRUCTION RISK ASSESSMENT (PCRA) CONTROL MEASURES, QUALITY ASSURANCE SURVEILLANCE PLAN (QASP), AND NATIONAL ENVIRONMENTAL POLICY ACT CONTROL MEASURES PRE-DETERMINED AND PROVIDED BY THE COR.
GENERAL NOTES
NOTES
1. DATA - ORANGE KEYSTONE
2. COAXIAL
3. FACEPLATE - STAINLESS STEEL
LABEL
LABEL
LABEL
LABEL
3 3
1-GANG 2-GANG
NOTES:
1. 24" HIGH WALL-MOUNTED RACK
2. 12-PORT FIBER FO PATCH PANEL
(ALTERNATE BID ITEM III, DEDUCT ALTERNATE III)
3. 48 PORT RJ-45 CAT 6A PATCH PANEL
(ALTERNATE BID ITEM II, DEDUCT ALTERNATE I & ALTERNATE BID ITEM III, DEDUCT ALTERNATE II)
4. 48 PORT CAT 6A DATA SWITCH
(ALTERNATE BID ITEM II, DEDUCT ALTERNATE I & ALTERNATE BID ITEM III, DEDUCT ALTERNATE II)
5. 6 PORT SFT 1 Gb FIBER SWITCH (WHEN NOTED ON DRAWING 100-EE600.)
6. HOSPITAL-GRADE POWER STRIP WITH 6 FOOT CORD.
7. MOUNTING HEIGHT SHALL MATCH EXISTING RACK HEIGHT.
8. MOUNT A 2' x 2' x 1/2" THICK PINE PLYWOOD SHEET NEXT TO RACK AS DETERMINED BY THE COR.
FRONT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:3
A M
100-EE001
ELECTRICAL LEGEND
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTSJOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
NTS
TYPICAL FACE PLATE DETAIL
1 1/2" = 1'-0"
TYPICAL DATA RACK ELEVATION DETAIL
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
D FINAL BID DOCUMENTS 04/26/2024
03/26/2024
DN
DN
E M
EM
EM
CR
E M
EM
E M
EM
EM
EM
EM
E M
EM
EM
EM
E M
EM
EM
E M
EM
EM
EM
E M
EM
EM
EM
EM
E M
E M
ELECTRICAL
LL775
TR
LL775A
MECHANICAL
LL776
CORRIDOR
CLL96
CORRIDOR
CLL109
FILE ROOM
LL772
ELECTRICAL
LL659
TR
LL659A
ELECTRICAL
LL554
TR
LL554A
ELECTRICAL
LL530
TR
LL530A
ELECTRICAL
LL050
TR
LL050A
ELECTRICAL
LL210
TR
LL210AELECTRICAL
LL214
ELECTRICAL
LL212
SERVER ROOM
LL246
ELECTRICAL
LL411
TR
LL411A
ZONE 1ZONE 2ZONE 3ZONE 4
ZONE 5ZONE 6
ZONE 7ZONE 8
ZONE 9ZONE 10
ZONE 13
BLDG 103
BLDG 100
100-EE100
3100-EE100
100-EE100
100-EE100
100-EE100
100-EE100
NEW RACK
ELECTRICAL
LL050
ELECTRICAL
LL050
TR
LL050A
NEW RACK
ELECTRICAL
LL210
ELECTRICAL
LL210
TR
LL210A
(E) RACK
NEW INTERNET
SERVICE DEMARC
ELECTRICAL
LL554
TR
LL554A
(E) RACK
EX PDI DIST
EX PDI DIST
NEW RACK
ELECTRICAL
LL775
TR
LL775A
NEW RACK
ELECTRICAL
LL212
ELECTRICAL
LL214
ELECTRICAL
LL214
NEW RACK
ELECTRICAL
LL411
ELECTRICAL
LL411
TR
LL411A
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:4
A M
100-EE100
ELECTRICAL PLAN - LOWER LEVEL
FLOOR OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/32" = 1'-0"
LOWER LEVEL OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
N
1/4" = 1'-0"
ENLARGED LOWER LEVEL CLOSET - LL050
N
1/4" = 1'-0"
ENLARGED LOWER LEVEL CLOSET - LL210
N
1/4" = 1'-0"
ENLARGED LOWER LEVEL CLOSET - LL554
N
1/4" = 1'-0"
ENLARGED LOWER LEVEL CLOSET - LL775A
N
1/4" = 1'-0"
ENLARGED LOWER LEVEL CLOSET - LL214
N
1/4" = 1'-0"
ENLARGED LOWER LEVEL CLOSET - LL411A
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
EM
E M
E M
EM
E M
E M
E M
EM
EM
E M
EM
E M
EM
E M
EM
E M
EM
EM
TR
A1026A
ELECTRICAL
A1026
TR
A1115A
ELECTRICAL
A1115
ELECTRICAL
A1114
ELECTRICAL
B1230
STAIR #05
SA105
ELECTRICAL
B1340A ELECTRICAL
B1340TR
B1340B
ELECTRICAL
C1514
TR
C1514A
TR
C1671A
ELECTRICAL
C1671
TR
C1772A
ELECTRICAL
C1772
ELECTRICAL
C1864
TR
C1864A
ZONE 11
ZONE 1ZONE 2ZONE 3ZONE 4
ZONE 5ZONE 6
ZONE 7ZONE 8
ZONE 9ZONE 10
ZONE 13
BLDG 103
BLDG 100
BLDG 101
100-EE101
100-EE101
100-EE101
100-EE101
100-EE101
100-EE101
100-EE101
ELECTRICAL
C1999E
(E) RACK
ELECTRICAL
B1340A
ELECTRICAL
B1340A
TR
B1340B
ELECTRICAL
A1026
TR
A1026A
(E) RACK
NEW RACK
ELECTRICAL
B1230
TR
B1230A
ELECTRICAL
C1864
TR
C1864A
(E) RACK
ELECTRICAL
C1514
TR
C1514A
(E) RACK
TR
C1999D
MECHANICAL
C1999C
NEW RACK
NEW RACK
ELECTRICAL
A1115
ELECTRICAL
A1115
NEW RACK
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:0
A M
100-EE101
ELECTRICAL PLAN - FIRST FLOOR
OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/32" = 1'-0"
FIRST FLOOR OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
N
1/4" = 1'-0"
ENLARGED FIRST FLOOR CLOSET - B1340A
N
1/4" = 1'-0"
ENLARGED FIRST FLOOR CLOSET - A1026
N
1/4" = 1'-0"
ENLARGED FIRST FLOOR CLOSET - B1230
N
1/4" = 1'-0"
ENLARGED FIRST FLOOR CLOSET - C1864
N
1/4" = 1'-0"
ENLARGED FIRST FLOOR CLOSET - C1514
N
1/4" = 1'-0"
ENLARGED FIRST FLOOR CLOSET - C1999D
N
1/4" = 1'-0"
ENLARGED FIRST FLOOR CLOSET - A1115A
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
M
E M
E M
EM
EM EM
EM
EM
E M
EM
E M
E M
EM
E M
E M
EM
E M
EM
EM EM
EM
EM
EM
EM
E M
ELECTRICAL
C2465
ELECTRICAL
C2571
TR
C2571A
TR
C2741A
ELECTRICAL
C2741
ELECTRICAL
C2981
TR
C2981A
ELECTRICAL
B2359
TR
B2359A
TR
B2239A
ELECTRICAL
B2239
TR
A2140A
ELECTRICAL
A2140
ELECTRICAL
A2031
TR
A2031A
TR
C2465A
ZONE 11
ZONE 1ZONE 2ZONE 3ZONE 4
ZONE 5ZONE 6
ZONE 7ZONE 8
ZONE 9ZONE 10
ZONE 13
BLDG 103
BLDG 100
BLDG 101
100-EE102
100-EE102
100-EE102
100-EE102
100-EE102
100-EE102
(E) RACK
ELECTRICAL
B2359
TR
B2359A
MECHANICAL
B2357
NEW RACK
ELECTRICAL
C2465
TR
C2465A
(E) RACK
ELECTRICAL
C2981
TR
C2981A
EX PDI DIST
EX PDI DIST
NEW RACK
ELECTRICAL
B2239
SECLUSION BATH
B2237A
CORRIDOR
CB209
ELECTRICAL
A2031
ELECTRICAL
A2031
TR
A2031A
(E) RACK
ELECTRICAL
A2140
ELECTRICAL
A2140
(E) RACK
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:3
A M
100-EE102
ELECTRICAL PLAN - SECOND
FLOOR OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/32" = 1'-0"
SECOND FLOOR OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
N
1/4" = 1'-0"
ENLARGED SECOND FLOOR CLOSET - B2359A
N
1/4" = 1'-0"
ENLARGED SECOND FLOOR CLOSET - C2465
N
1/4" = 1'-0"
ENLARGED SECOND FLOOR CLOSET - C2981
N
1/4" = 1'-0"
ENLARGED SECOND FLOOR CLOSET - B2239
N
1/4" = 1'-0"
ENLARGED SECOND FLOOR CLOSET - A2031
N
1/4" = 1'-0"
ENLARGED SECOND FLOOR CLOSET - A2140
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
M
EM
E M
EM
EM
E M
EM
EM
EM
EM
EM
EM
T V
ELECTRICAL
A3031
TR
A3031A
TR
A3142A
ELECTRICAL
A3142
ELECTRICAL
B3239
TR
B3239A
ELECTRICAL
B3361
TR
B3361A
TR
C3554A
ELECTRICAL
C3554
ELECTRICAL
C3676
TR
C3676A
TR
C3747A
ELECTRICAL
C3747
ELECTRICAL
C3841
TR
C3841A
ZONE 1ZONE 2ZONE 3ZONE 4
ZONE 5ZONE 6
ZONE 7ZONE 8
ZONE 9ZONE 10
BLDG 100
100-EE103
100-EE103
100-EE103
100-EE103
100-EE103
100-EE103
(E) RACK
ELECTRICAL
B3361
ELECTRICAL
B3361
TR
B3361A
(E) RACK
ELECTRICAL
A3031
ELECTRICAL
A3031
TR
A3031A
NEW RACK
TR
B3239A
ELECTRICAL
B3239
ELECTRICAL
B3239
NEW RACK
TR
C3554A
ELECTRICAL
C3554
(E) RACK
TR
C3841A
ELECTRICAL
C3841
ELECTRICAL
A3142
TR
A3142A
(E) RACK
EX PDI DIST
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:5
A M
100-EE103
ELECTRICAL PLAN - THIRD FLOOR
OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/32" = 1'-0"
THIRD FLOOR OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
N
1/4" = 1'-0"
ENLARGED THIRD FLOOR CLOSET - B3361
N
1/4" = 1'-0"
ENLARGED THIRD FLOOR CLOSET - A3031
N
1/4" = 1'-0"
ENLARGED THIRD FLOOR CLOSET - B3239
N
1/4" = 1'-0"
ENLARGED THIRD FLOOR CLOSET - C3554
N
1/4" = 1'-0"
ENLARGED THIRD FLOOR CLOSET - C3841
N
1/4" = 1'-0"
ENLARGED THIRD FLOOR CLOSET - A3142A
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
E M
EM
E M
E M
EM
E M
E M
E M
EM
EM
EM
TR
C4483A
ELECTRICAL
C4483
ELECTRICAL
C4654
TR
C4654A
TR
C4763A
ELECTRICAL
C4763
ELECTRICAL
C4967
TR
C4967A
ELECTRICAL
A4075
TR
A4075A
TR
A4144A
ELECTRICAL
A4144
ELECTRICAL
B4223
ELECTRICAL
B4355
TR
B4355A
ZONE 1ZONE 2ZONE 3ZONE 4
ZONE 5ZONE 6
ZONE 7ZONE 8
ZONE 9ZONE 10
BLDG 100
100-EE104
100-EE104
100-EE104
100-EE104
100-EE104
100-EE104
NEW RACK
ELECTRICAL
B4355
TR
B4355A
ELECTRICAL
B4355 NEW RACK
ELECTRICAL
A4075
TR
A4075A
ELECTRICAL
A4075
NEW RACK
ELECTRICAL
B4223
ELECTRICAL
B4223
TR
B4223A
NEW RACK
ELECTRICAL
C4483
TR
C4483A
NEW RACK
ELECTRICAL
C4967
TR
C4967A
ELECTRICAL
A4144
TR
A4144A
EX PDI DIST
(E) RACK
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:2
A M
100-EE104
ELECTRICAL PLAN - FOURTH
FLOOR OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/32" = 1'-0"
FOURTH FLOOR OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
N
1/4" = 1'-0"
ENLARGED FOURTH FLOOR CLOSET - B4355
N
1/4" = 1'-0"
ENLARGED FOURTH FLOOR CLOSET - A4075
N
1/4" = 1'-0"
ENLARGED FOURTH FLOOR CLOSET - B4223
N
1/4" = 1'-0"
ENLARGED FOURTH FLOOR CLOSET - C4483
N
1/4" = 1'-0"
ENLARGED FOURTH FLOOR CLOSET - C4967
N
1/4" = 1'-0"
ENLARGED FOURTH FLOOR CLOSET - A4144A
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
M
E M
EM
EM
EM/36"
EM/36"
EM
E M
EM
T V
T V
ELECTRICAL
B5378
TR
B5378A
ELECTRICAL
B5239 TR
A5144A
ELECTRICAL
A5144
ELECTRICAL
A5031
TR
A5031A
ZONE 1ZONE 2ZONE 3ZONE 4
ZONE 5ZONE 6
ZONE 7ZONE 8
ZONE 9ZONE 10
BLDG 100
100-EE105
100-EE105
100-EE105
100-EE105
NEW RACK
ELECTRICAL
B5378
ELECTRICAL
B5378
TR
B5378A
(E) RACK
EX PDI DIST
EX PDI DIST
ELECTRICAL
A5031
ELECTRICAL
A5031
TR
A5031A
ELECTRICAL
B5239
ELECTRICAL
B5239
TR
B5239A
NEW RACK
TR
A5144A ELECTRICAL
A5144
(E) RACK
EX PDI DIST
EX PDI DIST
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:3
A M
100-EE105
ELECTRICAL PLAN - FIFTH FLOOR
OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/32" = 1'-0"
FIFTH FLOOR OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
N
1/4" = 1'-0"
ENLARGED FIFTH FLOOR CLOSET - B5378
N
1/4" = 1'-0"
ENLARGED FIFTH FLOOR CLOSET - A5031
N
1/4" = 1'-0"
ENLARGED FIFTH FLOOR CLOSET - B5239A
N
1/4" = 1'-0"
ENLARGED FIFTH FLOOR CLOSET - A5144A
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
EM
EM
E M 36"
EM
E M
E M
EM
EM
TR
A6142A
ELECTRICAL
A6142
ELECTRICAL
A6031
TR
A6031A
ZONE 1ZONE 2
ZONE 5
100-EE106
100-EE106
(E) RACK
EX PDI DIST
EX PDI DIST
TR
A6142A
ELECTRICAL
A6142
(E) RACK
ELECTRICAL
A6031
TR
A6031A
EX PDI DIST
EX PDI DIST
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:5
A M
100-EE106
ELECTRICAL PLAN - SIXTH FLOOR
OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/32" = 1'-0"
SIXTH FLOOR OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
N
1/4" = 1'-0"
ENLARGED SIXTH FLOOR CLOSET - A6142
N
1/4" = 1'-0"
ENLARGED SIXTH FLOOR CLOSET - A6031
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
EM/36"
E M
TR
A7142A
ELECTRICAL
A7142
ELECTRICAL
A7031
TR
A7031A
ZONE 1ZONE 2
ZONE 5
100-EE107
100-EE107
NEW RACK
TR
A7142A
ELECTRICAL
A7142
(E) RACK
ELECTRICAL
A7031
ELECTRICAL
A7031
TR
A7031A
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:0
A M
100-EE107
ELECTRICAL PLAN - SEVENTH
FLOOR OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/32" = 1'-0"
SEVENTH FLOOR OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
N
1/4" = 1'-0"
ENLARGED SEVENTH FLOOR CLOSET - A7142
N
1/4" = 1'-0"
ENLARGED SEVENTH FLOOR CLOSET - A7031
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
(E) SATELLITE / CABLE RACKS/NETWORK
EQUIPMENT & HEADEND
(REMOVED/REPLACED/INSTALLED BY OTHERS)
ROOF MOUNTED ANTENNA
(BY OTHERS)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:1
A M
100-EE108
ELECTRICAL PLAN - EIGHTH
FLOOR OVERALL
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/8" = 1'-0"
EIGHTH FLOOR - OVERALL PLAN
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
D FINAL BID DOCUMENTS 04/26/2024
03/26/2024
NOTE: THIS SHEET FOR USE BY OTHERS
CONDUIT AND FIBER OPTICS FROM
DEMARC END LOCATION TO BE
DETERMINED BY THE COR. SEE COR AND
PLAN FOR A 50 FOOT FO SERVICE LOOP.
EM
EM
E M
EM
E M
EM
TV
TV
T V
84" MH
M H
M H
T V
TV
OFFICE
LL183
OFFICE
LL184
STORAGE
LL187
TOILET
LL185
CLOSET
LL184A
CONTROLED DRUGS
LL104
PHARMACY VAULT
LL105
STORAGE
LL107
H.A.C.
LL103
NON-HAZARDOUS BUFFER AREA
LL101A
HAZARDOUS BUFFER AREA
LL102A
ANTE
LL102
CLEAN ROOM
LL101
STORAGE
LL106
PHARMACY
LL109
CORRIDOR
CLL24
PHARMACY
LL100
PHARMACY
LL100A
OFFICE
LL115
OFFICE
A7116 OFFICE
A7118
OFFICE
LL117
RESEARCH LAB
LL119
OFFICE
LL127
WOMENS TOILET
LL129A
WOMENS LOCKERS
LL129
MENS LOCKERS
LL128
MENS TOILET
LL128A
LOUNGE
LL126
OFFICE
LL124
PHARMACY
LL111
ELECTRICAL
LL108
EXAM
LL020
CONSULATION ROOM
LL058
MRI ROOM
LL059
SIMULATION ROOM
LL061
TOILET
LL062
TREATMENT CONTROL ROOM
LL066
TREATMENT ROOM
LL067
CAST BLOCK ROOM
LL054
COMPUTER ROOM
LL056
ELECTRICAL
LL050
CORRIDOR
CLL12
WOMENS TOILET
LL028
MENS TOILET
LL030
LAB
LL053
SEALED SOURCE ROOM
LL055RADIATION THERAPY
LL026
SOILED UTILITY
LL027
CLEAN UTILITY
LL025
H.A.C.
LL023
OFFICE
LL021
OFFICE
LL039
OFFICE
LL037 OFFICE
LL035
OFFICE
LL033
STORAGE
LL032
LOUNGE
LL034
OFFICE
LL036OFFICE
LL038OFFICE
LL040
CORRIDOR
CLL08
STORAGE
LL013
TOILET
LL015
EXAM
LL017
EXAM
LL019
CORRIDOR
CLL19
CORRIDOR
CLL17
CHANGING ROOM
LL063
LOCKERS
LL064
CHANGING ROOM
LL065
CORRIDOR
CLL05
STORAGE
LL012
CLERK
LL011
WAITING
LL010
CORRIDOR
CLL09
CORRIDOR
CLL10
STORAGE
XXX
ELEVATOR #07
STAIR #02
SLL02
CORRIDOR
LL123
CORRIDOR
CLL15
CORRIDOR
CLL16
CORRIDOR
CLL13
CORRIDOR
CLL11
CORRIDOR
CLL14
CORRIDOR
CLL29
CORRIDOR
CLL07
TR
LL050A
CART LIFT #03
SA102j
MECHANICAL
LL052
PHARMACY CAGE
LL109A
AREA WELL
SA102k
CORRIDOR
CLL23
CORRIDOR
CLL02
STORAGE
LL008
TOILET
LL004A
TOILET
LL006A
CLEAN LINEN
LL003
ANTE
LL004
ANTE
LL006
CORRIDOR
CLL20
SOILED UTILITY
LL007
CART LIFT #01
A8006
CART LIFT #02
A8007
KITCHEN
LL142
KITCHEN
LL143
KITCHEN
LL141
H.A.C.
LL140
TREATMENT ROOM
LL068
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:2
A M
100-ET100.01
LOWER LEVEL ELECTRICAL PLAN -
ZONE 1
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/8" = 1'-0"
LOWER LEVEL NEW WORK PLAN - ZONE 1
D R A W I N G N O T E S :
1 PROVIDE DUPLEX RECEPTACLE FOR NEW TV. CIRCUIT TO LOCAL NORMAL POWER RECEPTACLE CIRCUIT.
2 SEE ENLARGED PLAN OF NEW RACK LOCATION ON OVERALL PLAN SHEET.
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
EM E
M
EM
EM
EM
OFFICE
LL191
OFFICE
LL193
CONFERENCE ROOM
LL171
BREAK ROOM
LL172
OFFICE
LL174
OFFICE
LL176
OFFICE
LL180
OFFICE
LL182
OFFICE
LL181OFFICE
LL179
OFFICE
LL177
OFFICE
LL196
OFFICE
LL194
OFFICE
LL192
OFFICE
LL186
CORRIDOR
CLL27
CORRIDOR
CLL26
CORRIDOR
CLL28
OFFICE
LL165
OFFICE
LL164
ELECTRICAL
LL210
STORAGE
LL202
CORRIDOR
CLL25
KITCHEN STORAGE
LL148
STORAGE
LL147
H.A.C.
LL146
KITCHEN
LL145
KITCHEN
LL142
KITCHEN
LL144
TR
LL210A
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:3
A M
100-ET100.02
LOWER LEVEL ELECTRICAL PLAN -
ZONE 2
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
1/8" = 1'-0"
LOWER LEVEL NEW WORK PLAN - ZONE 2
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
D R A W I N G N O T E S :
1 SEE ENLARGED PLAN OF NEW RACK LOCATION ON OVERALL PLAN SHEET.
2 SEE ENLARGED PLAN OF EXISTING RACK LOCATION ON OVERALL PLAN SHEET.
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
EME
EM
EM
EM
T V
T V
TV T
V
503 SF
CONFERENCE
LL219
461 SF
OFFICE
LL242
116 SF
OFFICE
LL235
121 SF
OFFICE
LL236
97 SF
OFFICE
LL237
164 SF
OFFICE
LL238
96 SF
STORAGE
LL239
2115 SF
OFFICE
LL220
113 SF
CORRIDOR
CLL48
202 SF
STORAGE
LL225
417 SF
COMPUTER ROOM
LL228
1260 SF
SERVER ROOM
LL246
401 SF
ELECTRICAL
LL247
468 SF
STORAGE
LL300
156 SF
OFFICE
LL302
2551 SF
STORAGE
LL301
6824 SF
MECHANICAL
LL215
2849 SF
AUDITORIUM
LL200
450 SF
STORAGE
LL203
69 SF
ELECTRICAL
LL212
174 SF
ELECTRICAL
LL214 123 SF
STAIR #05
SLL05
39 SF
TOILET
LL216A
422 SF
SWITCHBOARD
LL216
55 SF
STORAGE
LL204
1410 SF
ELECTRICAL ROOM - I.T. HUB
LL218
450 SF
AUDITORIUM STAGE
LL201
230 SF
CORRIDOR
CLL35
1382 SF
CORRIDOR
CLL37
1291 SF
CORRIDOR
CLL45
359 SF
CLASS ROOM
LL271
202 SF
STORAGE
LL273
530 SF
CORRIDOR
CLL43
60 SF
H.A.C.
LL276
55 SF
Room
LL274A
215 SF
CONFRENECE
LL254
120 SF
OFFICE
LL256
196 SF
OFFICE
LL258118 SF
OFFICE
LL259
317 SF
OFFICE CLERK
LL250
101 SF
LOCKERS
LL278
34 SF
TOILET
LL278A
101 SF
LOCKERS
LL280
34 SF
TOILET
LL280A
128 SF
CORRIDOR
CLL42
730 SF
AUTOPSY
LL274
208 SF
FREEZER
LL272
237 SF
VIEWING ROOM
LL270
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:4
A M
100-ET100.03
LOWER LEVEL ELECTRICAL PLAN -
ZONE 3
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/8" = 1'-0"
LOWER LEVEL NEW WORK PLAN - ZONE 3
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
D R A W I N G N O T E S :
1 SEE ENLARGED PLAN OF NEW RACK LOCATION ON OVERALL PLAN SHEET.
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
EM
EM
EM
EM
E
M
E M
M H
TV
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:4
A M
100-ET100.04
LOWER LEVEL ELECTRICAL PLAN -
ZONE 4
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/8" = 1'-0"
LOWER LEVEL NEW WORK PLAN - ZONE 4
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
D R A W I N G N O T E S :
1 PROVIDE DUPLEX RECEPTACLE FOR NEW TV. CIRCUIT TO LOCAL NORMAL POWER RECEPTACLE CIRCUIT.
2 SEE ENLARGED PLAN OF NEW RACK LOCATION ON OVERALL PLAN SHEET.
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
T V
M H
M H
M H
TV
TVTV
117 SF
OFFICE
LL636
151 SF
CONFERENCE ROOM
LL638
65 SF
H.A.C.
LL620
151 SF
PLOTER ROOM
LL639
493 SF
OFFICE
LL633
155 SF
CORRIDOR
CLL106538 SF
FLIGHT OPS
LL676
436 SF
STORAGE EQUIPMENT
LL682
1779 SF
BIOMEDICAL ENGINEERING
SHOP
LL678
80 SF
OFFICE
LL679
80 SF
H.A.C.
LL680
144 SF
OFFICE
LL681
505 SF
MAIL ROOM
LL686
665 SF
REPRODUCTION ROOM
LL692
156 SF
OFFICE
LL695
99 SF
OFFICE
LL693
93 SF
OFFICE
LL691
99 SF
OFFICE
LL689
99 SF
OFFICE
LL687
306 SF
CORRIDOR
CLL93
168 SF
CORRIDOR
CLL91
311 SF
CORRIDOR
CLL105
989 SF
OFFICE
LL712
108 SF
OFFICE
LL700
402 SF
STORAGE
LL771
113 SF
ELEVATOR MACHINE ROOM
LL768
46 SF
H.A.C.
LL767
32 SF
TOILET
LL766
102 SF
OFFICE
LL765
168 SF
WAITING
LL763
222 SF
CORRIDOR
CLL94
173 SF
OFFICE
LL764
126 SF
OFFICE
LL761
126 SF
OFFICE
LL760
433 SF
LOUNGE
LL762
1876 SF
OFFICE
LL750
411 SF
CORRIDOR
CLL92
824 SF
OFFICE
LL740
882 SF
OFFICE
LL738
258 SF
ELECTRIC SHOP
LL682A
187 SF
LOUNGE
LL678A
214 SF
LOCKSMITH
LL805A
927 SF
CORRIDOR
CLL30
134 SF
STORAGE
LL198 69 SF
STORAGE
LL199
392 SF
STAIR #04
SLL04
1898 SF
CORRIDOR
CLL21
660 SF
CORRIDOR
CLL03
1394 SF
MECHANICAL
LL002
156 SF
ELEVATOR LOBBY
CLL04
262 SF
CORRIDOR
CLL01
1846 SF
CORRIDOR
CLL20
66 SF
H.A.C.
LL154
141 SF
MISC. KITCHEN
LL155
111 SF
MECHANICAL
LL156
1132 SF
KITCHEN
LL159
402 SF
KITCHEN STORAGE
LL151
646 SF
KITCHEN STORAGE
LL150
1974 SF
WALK-IN FREEZER
LL149
280 SF
KITCHEN
LL153
182 SF
KITCHEN
LL152
1164 SF
KITCHEN
LL157
80 SF
KITCHEN
LL158
56 SF
COMPRESSOR ROOM
LL160
74 SF
ELEVATOR #03
A8017
74 SF
ELEVATOR #04
A8018
76 SF
ELEVATOR #01
A8019
75 SF
ELEVATOR #02
A8020
112 SF
SERVICE ELEVATOR #05
A8021
111 SF
SERVICE ELEVATOR #06
A8022
160 SF
STAIR #01
SA001
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /D e tr o it V
A
U p g ra d e
T V
S y s te m N e tw o rk
/F F
E
D e tr o it
U p g ra d e
T V
S y s te m M
E P rv t
/1
/2
:3
:5
A M
100-ET100.05
LOWER LEVEL ELECTRICAL PLAN -
ZONE 5
04/26/2024 JB IA
UPGRADE TV SYSTEM FROM
ANALOG TO DIGITAL
553-22-209
DETROIT, MICHIGAN
FINAL BID DOCUMENTS
JOHN D.
DINGELL VA
MEDICAL
CENTER
Approved: Owner
N
1/8" = 1'-0"
LOWER LEVEL NEW WORK PLAN - ZONE 5
D R A W I N G N O T E S :
1 PROVIDE DUPLEX RECEPTACLE FOR NEW TV. CIRCUIT TO LOCAL NORMAL POWER RECEPTACLE CIRCUIT.
KEY PLAN
South Parking Deck
BLDG
North Parking Deck
BLDG
BLDG 103
8 7
2 1
No. Revisions: Date:
A DESIGN DEVELOPMENT 65% 12/01/2023
B CONSTRUCTION DOCUMENTS 95% 02/05/2024
C CONSTRUCTION BID DOCUMENTS 02/25/2024
TV
TV
M H
TV
TV
210 SF
ANIMAL HOUSING
LL353
152 SF
LAB
LL361
146 SF
LAB
LL362
156 SF
LAB
LL363
268 SF
FOOD/BEDDING
LL364
109 SF
LOCKER
LL365
129 SF
STORAGE
LL366
86 SF
LOCKER
LL367
72 SF
KITCHEN
LL364A
53 SF
WALK-IN FRIDGE
LL364B
43 SF
TOILET
LL365A
45 SF
TOILET
LL367A
224 SF
CORRIDOR
CLL82
655 SF
CORRIDOR
CLL84
797 SF
SOILED LINEN
LL514
108 SF
STORAGE
LL512
1623 SF
CLEAN LINEN
LL515
128 SF
STORAGE
LL513
739 SF
WAREHOUSE STORAGE
LL517
16892 SF
WAREHOUSE STORAGE
LL516
111 SF
OFFICE
LL637
116 SF
OFFICE
LL635
165 SF
OFFICE
LL634
235 SF
STORAGE
LL621
307 SF
OFFICE
LL640
685 SF
CORRIDOR
CLL89
214 SF
CONFERENCE
LL623
34 SF
CART LIFT #08
53 SF
CORRIDOR
CLL87115 SF
LOCKERS
LL607
35 SF
TOILET
LL607A
231 SF
LOUNGE
LL540
154 SF
CHANGING ROOM
LL606
208 SF
LOCKERS
LL608
35 SF
TOILET
LL608A
67 SF
H.A.C.
LL610
30 SF
STORAGE
LL604
634 SF
CORRIDOR
CLL88
614 SF
CORRIDOR
CLL86
1488 SF
PREP ROOM
LL558
256 SF
GAS ROOM
LL559
243 SF
OFFICE
LL600
456 SF
WASH BAY
LL601
55 SF
H.A.C.
LL603
1323 SF
DECONTAMINATION ROOM
LL605
73 SF
WASHING MECHANICAL
LL602
1512 SF
IT STORAGE
LL519
151 SF
AUDITORIUM SUPPORT
LL205
264 SF
CORRIDOR
CLL32
392 SF
STAIR #04
SLL04530 SF
CORRIDOR
CLL33
111 SF
STORAGE
LL206
365 SF
WOMENS TOILET
LL207
410 SF
MENS TOILET
LL208
1410 SF
ELECTRICAL ROOM - I.T. HUB
LL218
1368 SF
CORRIDOR
CLL51
1270 SF
CORRIDOR
CLL41
1613 SF
CORRIDOR
CLL31
128 SF
CORRIDOR
CLL34
191 SF
STORAGE
LL306
109 SF
LOUNGE
LL257
130 SF
OFFICE
LL255
130 SF
STORAGE
LL261
311 SF
STORAGE EQUIPMENT
LL260
494 SF
CORRIDOR
CLL401204 SF
SUPPLY ROOM
LL262
330 SF
TOILET
LL268
335 SF
TOILET
LL265
36 SF
COMPRESSOR ROOM
LL266
43 SF
STORAGE
LL263
242 SF
CORRIDOR
CLL61
291 SF
ELEVATOR LOBBY
CLL52
317 SF
LOCKERS
LL267
132 SF
CORRIDOR
CLL46
138 SF
LOCKERS
LL267A
57 SF
SHOWERS
LL267B
135 SF
EQUIPMENT
LL264A
186 SF
CORRIDOR
CLL44
363 SF
LOCKERS
LL264
57 SF
SHOWERS
LL264B
75 SF
ELEVATOR #11
A8008
75 SF
ELEVATOR #12
A8009
75 SF
ELEVATOR #14
A8010
75 SF
ELEVATOR #13
A8011
90 SF
SERVICE ELEVATOR #16
A8012
90 SF
SERVICE ELEVATOR #15
A8013
93 SF
ELEVATOR #10
A8014
93 SF
ELEVATOR #09
A8015
86 SF
ELEVATOR #08
A8016
207 SF
STAIR #07
SLL07
G E N E R A L N O T E S:
A. INSTALLATION OF BOXES AND FACEPLATES: SEE DRAWING 100-EE001 DETAIL 1.
B. INSTALLATION OF NEW RACKS: SEE DRAWING 100-EE001 DETAIL 2.
C. ALL CAT6A ETHERNET INSTALLATIONS AND ASSOCIATED WORK BY…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .