Drawings 2 of 2 for 825CM3013 Renovate Maintenance Facility _ Roads.pdf
PDF 13 MB Posted
- Attached to
- Y1AZ--825CM3013 Alexandria NC Roads and Restroom
- Solicitation number
- 36C78623B0010
About this file
This document provides details for a federal contract solicitation. Solicitation number 36C78623B0010 is for a project to renovate the maintenance facility and roads at the National Cemetery Administration in Alexandria, Louisiana. The work includes drawings 2 of 2 for road and restroom renovations. The solicitation was issued by the Department of Veterans Affairs National Cemetery Administration for project number 825CM3013. The response is due by the date specified in the solicitation. The contract will be awarded to a vendor that can complete the road, maintenance facility and restroom renovations by the required completion date at a competitive price.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78623B0010 0003.docx | DOCX document | |
| 01 45 00 Quality Control Revised 4-12-2023.pdf | ||
| 01 35 26 Safety Requirements - Revised 4-12-2023.pdf | ||
| 36C78623B0010 0002.docx | DOCX document | |
| 36C78623B0010 0001.docx | DOCX document | |
| LIQUIDATED DAMAGES FORMULATION.docx | DOCX document | |
| Asbestos Survey - Alexandria Cemetery EH217091 9-24-21.pdf | ||
| Paint Chip Survey - Alexandria Cemetery EH217092 10-6-21.pdf | ||
| Limitations on Subcontracting Certificate for 825CM3013 Renovate Maintenance Facility _ Roads.docx | DOCX document | |
| 36C78623B0010_1.docx | DOCX document | |
| IFB Lump Sum Division Spreadsheet.xlsx | XLSX spreadsheet | |
| Specifications for 825CM3013 Renovate Maintenance Facility _ Roads.zip | ZIP file | |
| Drawings 1 of 2 for 825CM3013 Renovate Maintenance Facility _ Roads.pdf | ||
| RFI Form.docx | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
DUCTWORK SYMBOLS
ACU
AFF
AD
AHU
AL
BHP
BOD
BTU
BOP
BTUH
CA
CFM
CD
CONT.
COR
CU
D
DX
ENT
EXH
EMCS
FB
°F
FCU
F.G.
FD
FLEX
FPM
FS
FT.
FT
GPM
GPH
HB
HD
IN
HEPA
IU
KW
KWH
MA
MCC
NA
NO.
NIC
OBD
OA
PRV
PSIG
QTY
QUAD
Rh
R.A.
RS
RL
ST
SP
RPM
SCD
SDVV
TOPT
TP
TYP.
V
VAC
VAV
VTR
VEL
QUANTITY
QUADRANT
RETURN AIR
REVOLUTIONS PER MINUTE
RELATIVE HUMIDITY
REFRIGERATION LIQUID
REFRIGERATION SUCTION
SMOKE CONTROL DAMPER
SINGLE DUCT VARIABLE VOLUME
STATIC PRESSURE (INCHES OF WATER)
SOUND TRAP
SIDEWALL SUPPLY REGISTER
TOP OF PIPE TRAPEZE
TOTAL PRESSURE (INCHES OF WATER)
TYPICAL
VOLTS
24"x12"
VOLTS, ALTERNATING CURRENT
VARIABLE AIR VOLUME
VENT THRU ROOF
VELOCITY
24"/12"
12"Ø
SD
24x12
12"Ø
24x12Ø
SD
EQUIPMENT SYMBOLS
DUCT MOUNTED SMOKE DETECTOR
XX-##
DUCT MOUNTED STATIC PRESSURE PROBE
ACCESS DOOR
SIDEWALL GRILLE DIMENSION WHERE
SHOWN ON PLANS
T
H
CO
SEE CONTROL DRAWINGS FOR TYPE
ROOM THERMOSTAT/TEMP. TRANSMITTER LOCATION ONLY
ROOM HUMIDISTAT/HUMIDITY TRANSMITTER LOCATION ONLY
SEE CONTROL DRAWINGS FOR TYPE
ROOM CARBON DIOXIDE TRANSMITTER LOCATION ONLY
SEE CONTROL DRAWINGS FOR TYPE
##x##
XX-#
SYMBOL INDICATES GRILLE OR DIFFUSER
IDENTIFIED IN EQUIPMENT SCHEDULE
CFM
F. SEE SPECIFICATION SECTION 230593, TESTING, ADJUSTING, & BALANCING OR
MECHANICAL SYSTEMS FOR ADDITIONAL DESCRIPTION AND REQUIREMENTS.
G. ALL TEST AND MEASUREMENT TRAVERSE LOCATIONS SHALL BE CLEARLY NOTED ON
FLOOR PLANS WHICH SHALL BE INCLUDED WITH THE TEST AND MEASUREMENT DATA.
H. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES
INCLUDING MECHANICAL, PLUMBING, ELECTRICAL, FURNITURE, AND ARCHITECTURAL.
ANY DISCREPANCIES SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT PRIOR
TO START OF WORK.
I. ALL NEW TO EXISTING DUCT CONNECTIONS SHALL BE FIELD VERIFIED PRIOR TO
ORDERING AND FABRICATING NEW DUCTWORK OR DAMPERS
LETTERS REFER TO THE EQUIPMENT TYPE
NUMBERS REFER TO SPECIFIC EQUIPMENT
SYMBOL INDICATES EQUIPMENT IDENTIFIED
IN EQUIPMENT SCHEDULE
DUCT TRANSITION FROM RECTANGULAR TO ROUND
DUCT TRANSITION
INDICATES A 24"x12" RECTANGULAR DUCT (WIDTH x DEPTH)
INDICATES A 12" ROUND DUCT
INDICATES A 24"x12" FLAT OVAL DUCT (WIDTH x DEPTH)
DOWN
DIRECTION PITCH
DIRECTION OF FLOW
DEMO
EXISTING
DETAIL NUMBER LOCATION
SECTION LETTER LOCATION
A1
A1
SCALE
SECTION
A. THE DEMOLITION DRAWINGS REFLECT INFORMATION ON EXISTING BUILDING
SERVICES GATHERED BY SITE INSPECTION, DISCUSSIONS WITH MAINTENANCE
PERSONNEL AND PREVIOUS CONSTRUCTION DRAWINGS. THE EXACT LOCATION,
ARRANGEMENT, AND SIZES OF PIPE LINES AND DUCTWORK IN THE EXISTING BUILDING
MAY BE DIFFERENT FROM THAT SHOWN ON THESE DRAWINGS.
SCALE
DETAIL
B. THE CONTRACTOR SHALL COORDINATE THE SHUTDOWN OF EXISTING BUILDING
SERVICES FOR REMOVAL WITH OWNER AUTHORIZED REPRESENTATIVE AND SHALL
CONFORM TO THEIR REQUIREMENTS.
C. DISRUPTION OF NORMAL FACILITY ACTIVITIES ARE TO BE KEPT TO AN ABSOLUTE
MINIMUM. DUST, DEBRIS, AND FUMES SHALL BE CONTROLLED SO AS NOT TO AFFECT
THE HEALTH AND SAFETY OF OCCUPIED AREAS WITHIN THE FACILITY WHICH ARE
OUTSIDE THE AREA OF WORK. COORDINATE WITH THE ARCHITECT AND THE
OWNER'S REPRESENTATIVE WITH REGARD TO ALL ACTIVITIES TO BE CONDUCTED
OUTSIDE OF THE SUITE REMODEL AREA WHICH MAY AFFECT THE OPERATION OF THE
FACILITY.
D. THE CONTRACTOR SHALL PROVIDE TEMPORARY VENTILATION (MAINTAIN WORK ZONE
AT NEGATIVE PRESSURE), FILTRATION, AIR PURIFIERS, DUST SCREENS, ETC. FOR ALL
WORK AREAS AFFECTED BY DEMOLITION FOR NEW INSTALLATION TO MINIMIZE DUST
AND FUMES.
E. THE CONTRACTOR SHALL PRESENT AN AREA BY AREA WORK PLAN WELL IN ADVANCE
TO THE ARCHITECT AND THE OWNER'S AUTHORIZED REPRESENTATIVE FOR
APPROVAL PRIOR TO BEGINNING WORK. THE WORK PLAN SHALL INCLUDE AN
OUTLINE OF ALL ACTIVITIES OF ALL SUBCONTRACTORS. THE CONTRACTOR SHALL
COORDINATE WITH THE OWNER'S AUTHORIZED REPRESENTATIVE TO ESTABLISH
ACCEPTABLE ROUTING AND ACCESS WITHIN THE FACILITY FOR MATERIALS REQUIRED
FOR THE NEW INSTALLATION.
SIDEWALL EXHAUST OR RETURN AIR GRILLE
OR REGISTER
CEILING RETURN AIR REGISTER OR GRILLE
CEILING EXHAUST REGISTER
ENTERING
EXHAUST
ENERGY MANAGEMENT CONTROL SYSTEM
DEGREES FAHRENHEIT
FLAT BOTTOM
FLOOR DRAIN
FAN COIL UNIT
FILTER GAUGE
FLEXIBLE
FEET PER MINUTE
FLOOR SINK
FEET
FLAT TOP
GALLONS PER MINUTE
GALLONS PER HOUR
HOSE BIBB
HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HAND DAMPER (VOLUME DAMPER)
INCHES
INDOOR UNIT
KILOWATT
MAIN AIR (CONTROLS)
KILOWATT HOUR
MOTOR CONTROL CENTER
NUMBER (QUANTITY)
NOT IN CONTRACT
NOT APPLICABLE
OPPOSED BLADE DAMPER
OUTSIDE AIR
PRESSURE REDUCING VALVE
POUNDS PER SQUARE INCH GAGE
PERFORATED FACE CEILING DIFFUSERS
HWS
HWR
CHS
CHR
STAMPED FACE CEILING DIFFUSERS
V
D
CD
MU
RS
RL
R
TWS
TWR
TWB
MPS
HPS
LPS
HPR
HPR
LPR
CND
PC
GWS
GWR
HEATING WATER RETURN
HEATING WATER SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
DRAIN
CONDENSATE DRAIN
MAKE-UP WATER
VENT
REFRIGERATION LIQUID
REFRIGERATION SUCTION
REFRIGERATION
TOWER WATER BYPASS
TOWER WATER RETURN
TOWER WATER RETURN
STEAM - HIGH PRESSURE SUPPLY
STEAM - HIGH PRESSURE RETURN
STEAM - MEDIUM PRESSURE SUPPLY
STEAM - LOW PRESSURE SUPPLY
CONDENSER WATER
PUMPED CONDENSATE
GEOTHERMAL SUPPLY
GEOTHERMAL RETURN
SECTION AND DETAIL TITLES
STEAM - MEDIUM PRESSURE RETURN
STEAM - LOW PRESSURE RETURN
DRAWING NUMBER WHERE DETAILED
SECTION LOCATION
DETAIL SYMBOL
DETAIL LOCATION
DRAWING NUMBER WHERE DETAILED
X#/X###
M301
A1
SECTION SYMBOL
B
M
RETURN DUCT
PIPING SYMBOLS
EXHAUST DUCT
MECHANICAL PIPING
SUPPLY DUCT
EXISTING DUCT TO BE REMOVED
FLEXIBLE CONNECTION
RISE IN DUCT
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES
EXCEPT TRANSFER AIR SOUND ELBOW)
SHORT RADIUS ELBOW (PROVIDE ALL
SQUARE OR RECTANGULAR ELBOWS WITH
VANES EXCEPT TRANSFER AIR SOUND
ELBOW)
STANDARD LONG RADIUS ELBOW
3/4" BALL VALVE WITH ADAPTER
TO 3/4" HOSE THREAD
DIAPHRAGM VALVE
BUTTERFLY VALVE
BALL VALVE
VALVE IN RISE
WATER FLOW MEASURING DEVICE
CIRCUIT SETTER
F
S
SOLENOID VALVE
POINT OF CONNECTION, NEW DUCT TO EXISTING DUCT
OR / POINT OF REMOVAL FROM EXISTING DUCT TO DEMO DUCT
AIR CONDITIONING UNIT
ABOVE FINISHED FLOOR
ACCESS DOOR
AIR HANDLING UNIT
ACOUSTIC LINING
BRAKE HORSEPOWER
BOTTOM OF DUCT
BOTTOM OF PIPE
BTU PER HOUR
BRITISH THERMAL UNIT
COMPRESSED AIR
CUBIC FEET PER MINUTE
CONDENSATE DRAIN
CONTINUATION
CONTRACTING OFFICER'S REPRESENTATIVE
CONDENSING UNIT
DRAIN
DIRECT EXPANSION
S.DPR
F.DPR
F/S DPR
COMBINATION FIRE/SMOKE DAMPER
PRESSURE REDUCING VALVE
2HR. SMOKE BARRIER
SMOKE BARRIER
2HR. FIRE BARRIER
1 HR. FIRE BARRIER
M
VERIFY WITH
ARCHITECTURAL
DRAWINGS
M
3-WAY
MODULATING
CONTROL VALVE
A
2-WAY CONTROL VALVE
SAFETY VALVE OR
PRESSURE RELIEF
VALVE
P
PS PS
GAUGE - DIFFERENTIAL
GAUGE - PRESSURE
GAUGE - PRESSURE WITH COCK
GAUGE - TEMPERATURE
HS
PS
TS
PIPE ANCHOR
PIPE EXPANSION JOINT
PIPE GUIDE
SENSOR - FLOW
SWITCH - FLOW
SWITCH HUMIDITY
SWITCH - PRESSURE
SWITCH - TEMPERATURE
TEMPERATURE - PRESSURE TEST FITTING
THERMOMETER
THERMOMETER WELL
BASKET STRAINER
STEAM TRAP INVERTED BUCKET
METER - TOTALIZING BTU
METER - TOTALIZING FLOW
AIR VENT - AUTOMATIC
AIR VENT - MANUAL
G. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL FIRE
RATED AND/OR SMOKE RATED WALLS AND ASSEMBLIES. PROVIDE APPROVED
FIRE DAMPERS IN ALL REQUIRED PENETRATIONS FOR DUCTWORK, GRILLES,
REGISTERS AND DIFFUSERS. ALL PIPE AND DUCTWORK PENETRATIONS OF FIRE,
SMOKE AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT
STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.
H. CONTRACTOR SHALL COORDINATE ALL DUCTWORK, PIPING, PLUMBING AND
FIRE PROTECTION PIPING WITH STRUCTURAL AND ELECTRICAL SYSTEMS AND
SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
EQUIPMENT ACCESS AND SERVICEABILITY.
I. CONTRACTOR SHALL FURNISH ALL NECESSARY STRUCTURES, INSERTS,
SLEEVES, AND HANGING DEVICES FOR INSTALLATION OF MECHANICAL AND
PLUMBING EQUIPMENT, DUCTWORK AND PIPING, ETC. CONTRACTOR SHALL
COORDINATE WITH GENERAL CONTRACTOR AND ALL BUILDING TRADES TO AVOID
CONFLICTS AND TO MAINTAIN EQUIPMENT ACCESS AND SERVICEABILITY.
J. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY
MISCELLANEOUS ANGLES, CHANNELS, UNISTRUT, ETC., AS MAY BE REQUIRED TO
ADEQUATELY SUPPORT THE MECHANICAL PIPING, DUCTWORK, AND EQUIPMENT
IN A MANNER APPROVED BY THE ARCHITECT, WHICH WILL NOT OVERLOAD THE
BUILDING STRUCTURAL SYSTEM.
K. CONTRACTOR SHALL PROVIDE RETURN AIR OR TRANSFER AIR OPENINGS IN
FULL HEIGHT WALLS SIZED AT 350 FPM (UNLESS OTHERWISE SPECIFICALLY
SHOWN ON THE DRAWINGS) TO CREATE AND/OR MAINTAIN A RETURN AIR PATH AS
REQUIRED. FIRE DAMPERS AND/OR SMOKE DAMPERS SHALL BE PROVIDED IN
SUCH OPENINGS WHERE REQUIRED BY NOTE "J".
L. SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, DUCT WALL
PENETRATIONS AND FITTING CONNECTIONS ON ALL DUCT SYSTEMS.
M. MECHANICAL ITEMS SUCH AS ROOF DRAINS, FLOOR DRAINS, PLUMBING FIXTURES,
ETC. SHOWN ON THE ARCHITECTURAL DRAWINGS BUT NOT SHOWN ON THE
MECHANICAL DRAWINGS SHALL BE INCLUDED IN THE PROJECT. THESE ITEMS
SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR INCLUSION IN
ADDENDUM.
N. IT IS CRITICAL THAT THE CONTRACTOR PERFORM A COMPLETE REVIEW OF ALL
SUBMITTALS PRIOR TO SUBMISSION TO THE AE/COR. INCOMPLETE, INCORRECT
AND UNCLEAR SUBMITTALS WILL BE REJECTS AND MARKED AS "REVISE AND
RESUBMIT". ALL SUBMITTALS MUST CLEARLY INDICATE THE EQUIPMENT
SELECTIONS FOR THE PROJECT. TECHNICAL DRAWINGS OF COMPLETE
ASSEMBLIES, REFLECTING ACCURATE PROJECT CONDITIONS, SHALL BE
SUBMITTED WITH EQUIPMENT SELECTIONS TO ENSURE SPACE ALLOWANCES ARE
REFLECTED IN THE ACTUAL SPACE AVAILABLE. WHERE SIZE DEVIATIONS DIFFER
FROM THE BASIS OF DESIGN CONTRACTOR SHALL HIGHLIGHT THE DIFFERENCES
FOR AE/COR REVIEW WITHIN THE SUBMITTAL. CONTRACTOR SHALL PROVIDE
INSTALLATION ROUTE AND VERIFICATION THAT ACCESS POINTS, PLACEMENT
ROUTE, SUPPORTS, AND REQUIRED EQUIPMENT CLEARANCES ARE IDENTIFIED ON
THE ROUTE DRAWING. SAFETY PROTOCOLS FOR SUBJECT STATION SHALL BE
REFLECTED ON EQUIPMENT CLEARANCES. PLATFORMS AND INTERFACE AREAS
(FILTER, GAUGES, MONITORS, VALVES, ETC.) SHALL HAVE PROPER CLEARANCE AS
DEFINED BY THE MANUFACTURER, VA SAFETY PERSONNEL AND SERVICE
PERSONNEL. ACCESS POINTS OF USE SHALL BE CLEARLY IDENTIFIED ON THE
DRAWINGS.
GENERAL DEMO NOTES
PIPE REDUCER - ECCENTRIC
PIPE STRAINER
UNION - SCREWED
FIRE DAMPER
SMOKE DAMPER
CHECK VALVE
PLUG VALVE
ACOUSTICAL DUCT LINING
FLEXIBLE DUCT
MANUAL BALANCING DAMPER
GATE VALVE
MECHANICAL SYMBOL LEGEND
VALVE SYMBOLS
GLOBE VALVE
ELBOW - DROP TO TEE
TEE - DROP FROM TEE
END CAP
FLEX CONNECTION
PIPE REDUCER - CONCENTRIC
GENERAL NOTES
FITTING SYMBOLS
ELBOW - DOWN
ELBOW - UP
PIPE RISE-DROP
A. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN
FURRED CHASES OR SUSPENDED CEILINGS, UNLESS OTHERWISE NOTED.
B. PROVIDE ACCESS PANELS OR DOORS IN INACCESSIBLE CEILINGS AND/OR
CHASES FOR ALL VALVES, TRAPS, DAMPERS, CLEANOUTS, COILS, FANS,
CONTROLS, ETC. THEY SHALL BE FURNISHED UNDER DIVISION 23 AND
INSTALLED UNDER THE ARCHITECTURAL SPECIFICATION. ACCESS DOOR RATING
SHALL MATCH CLASSIFICATION OF WALL AND CEILING FIRE RATING.
C. COORDINATE THE LOCATION OF ALL DIFFUSERS, GRILLES, REGISTERS, ACCESS
DOORS, ETC., WITH THE ARCHITECTURAL REFLECTED CEILING PLAN(S).
D. ALL ROUND RUNOUTS AND DROPS TO DIFFUSERS SHALL BE THE SAME NOMINAL
SIZE AS THE SCHEDULED DIFFUSER NECK SIZE.
E. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR
INDICATED. ALL DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE DIMENSIONS.
PROVIDE ONE INCH ACOUSTICAL LINING (TYPE D3 INSULATION) IN LOW VELOCITY
RECTANGULAR DUCTWORK FOR THE FIRST 10 DIAMETERS OF DUCTWORK
CONNECTED TO DEVICE, OR AS INDICATED ON DRAWINGS, WHICHEVER IS
GREATER. FOR THE REMAINDER OF THIS DUCTWORK PROVIDE AS INDICATED IN
THE INSULATION SPECIFICATIONS.
F. PROVIDE 1/2" MANUAL AIR VENTS AT ALL HIGH POINTS OF CLOSED SYSTEM PIPING
AND 1/2" MANUAL DRAIN VALVES WITH HOSE CONNECTION AT LOW POINTS AS
REQUIRED TO PROVIDE COMPLETE SYSTEM DRAINAGE. WHERE DRAIN VALVES
OCCUR ABOVE CEILING AREAS AND IN AREAS OUTSIDE MECHANICAL RANGE
PROVIDE HOSE CONNECTION ON VALVE.
ELECTRICAL DISCONNECT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
BID DOCUMENTS
7/29/22
M-001
MECHANICAL SYMBOLS &
ABBREVIATIONS
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
WH
A B C E
D
1. DEMO GAS UNIT HEATER INCLUDING SUPPORT HANGER AND FLUE VENT.
2. DEMO CEILING EXHAUST FAN INCLUDING DUCTWORK AND ROOF TERMINATION VENT
(NOT ALL KEYED NOTES USED ON THIS SHEET)DEMOLITION KEYED NOTES:
3. DEMO CEILING MOUNTED ELECTRIC HEATER
4. DEMO (2) WALL MOUNTED ELECTRIC HEATERS, INCLUDING WIRING BACK TO PANEL.
5. DEMO WALL MOUNTED ELECTRIC HEATER, INCLUDING WIRING BACK TO PANEL.
6. DEMO WINDOW AC UNIT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
BID DOCUMENTS
7/29/22
MD101
MECHANICAL DEMOLITION FLOOR
PLAN
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
MECHANICAL DEMO PLAN
B4
1. NEW CEILING FAN, TERMINATE 4"Ø VENT AT ROOF JACK.
2. NEW GAS FIRED UNIT HEATER, CONNECT TO EXISTING GAS LINE. INSTALL 6"Ø FLUE
VENT, TERMINATE AT ROOF VENT.
3. NEW WALL MOUNTED DUCTLESS SPLIT SYSTEM FOR HEATING AND COOLING.
4. NEW RECESSED WALL MOUNTED ELECTRIC HEATER.
5. INSTALL NEW HEAT PUMP OUTDOOR UNIT WITH DUAL ZONE CAPABILITY ON 4"
CONCRETE PAD.
(NOT ALL KEYED NOTES USED ON THIS SHEET)REMODEL KEYED NOTES:
F D
A B C E
D
FCU-01
EF-01
HP-01
EF-01
UH-01
UH-01
FCU-01
EH-01
EH-01
6. INSTALL TRANSFER GRILL, KRUEGER 5600 14x6 WITH BOTTOM OF GRILL AT 12" ABOVE
BOTTOM OF DOOR. PROVIDE WITH INSECT SCREEN.
7. INSTALL WALL VENT, KRUEGER 5600, 14x6 WITH BOTTOM OF GRILL MIN 7FT ABOVE
FINISHED FLOOR.
8. INSTALL AND ROUTE CONDENSATE LINE THRU EXTERIOR WALL TERMINATE AT DRY
WELL.
9. QEL CTS-M5 CO SENSOR, CONNECT GARAGE OPENER TO DRY CONTACT ON SENSOR
TO OPEN GARAGE DOOR WHEN CO ALARM IS ACTIVE.
EF-01
CO
CO
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
BID DOCUMENTS
7/29/22
MH101
REMODEL MECHANICAL FLOOR
PLAN
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
MECHANICAL REMODEL PLAN
B1
SPLIT SYSTEM HEAT PUMP REFRIGERANT PIPING
NTS
SYMBOL
NO.
MANUFACTURER/MODEL
NO.
TYPE
SENSIBLE
COOLING
CAPACITY
(BTU/H)
FCU-01 MSZ-FH06NA * WALL MOUNTED 6,000
FAN COIL UNIT SCHEDULE
SUPPLY
AIRFLOW
(CFM)
SOUND
(dBA)
ELECTRICAL DATA
VOLTS PHASE HZ MCA
120 1 60 1.0
WIDTH (IN)
HEIGHT
(IN)
12.25
WEIGHT
(LBS)
30.1
SYMBOL
NO.
MANUFACTURER/MODEL
NO.
TYPE
CFM
EF-01 GREENHECK SPB90 CEILING 60
EXHAUST FAN SCHEDULE
S.P.
INCH W.C.
0.3
SOUND
(SONES)
1.5
ELECTRICAL DATA
VOLTS PHASE HZ HP
120 1 60 .01
WIDTH (IN)
14.5
HEIGHT
(IN)
7.25
WEIGHT
(LBS)
10.5
*BASED ON MITSUBISHI
SYMBOL
NO.
MANUFACTURER/MODEL
NO.
SENSIBLE
COOLING
CAPACITY
(BTU/H)
HP-01 MXZ-2C20NA2-U1 * 18,000 22,000
DUAL ZONE HEAT PUMP OUTDOOR UNIT SCHEDULE
12,500
SOUND
(dBA)
ELECTRICAL DATA
VOLTS PHASE HZ MCA
208/230 1 60 17.2 20.0
DIM
(IN)
28x33x13
WEIGHT
(LBS)
*BASED ON MITSUBISHI
HEATING
CAPACITY
(BTU/H)
@47°F
HEATING
CAPACITY
(BTU/H)
@17°F
MOCP
SYMBOL
NO.
MANUFACTURER/MODEL
NO.
UH-01 REZNOR UDX 30 45,000 37,000
GAS FIRED UNIT HEATER SCHEDULE
VENT DIA.
(IN.)
ELECTRICAL DATA
VOLTS PHASE HZ MCA
120 1 60 3.0 15
DIM
(IN)
14x27x26
WEIGHT
(LBS)
HEATING
CAPACITY
(BTU/H)
BLOWER
FAN
(CFM)
MOCP
INPUT
HEATING
CAPACITY
(BTU/H)
OUTPUT
SYMBOL
NO.
MANUFACTURER/MODEL
NO.
EH-01 QMARK CWH1202DSF 6,826 2.0
ELECTRIC WALL HEATER SCHEDULE
TSTAT
INTEGRAL
ELECTRICAL DATA
VOLTS PHASE HZ MCA
240 1 60 9.0 15
DIM
(IN)
12x11x5
WEIGHT
(LBS)
HEATING
CAPACITY
(BTU/H)
BLOWER
FAN
(CFM)
MOCP
HEATING
CAPACITY
(kW)
PAD MOUNTED HEAT PUMP, 4" CONCRETE PAD
INDOOR UNIT, DIRECT EXPANSION (DX) COIL.
DISTRIBUTION NOZZLE
GLOBE VALVES AT OUTDOOR UNIT.
SWING JOINT.
PIPE PENETRATION THROUGH ROOF, SEE PIPING THRU ROOF
DETAIL ON THIS SHEET.
REFRIGERANT SUCTION LINE
REFRIGERANT LIQUID LINE
SIGHT GLASS
REMOTE BULB
FILTER
LIQUID CHARGING VALVE
STRAINER
SOLENOID VALVE TO BE LOCATED AS CLOSE
TO EXPANSION VALVE AS POSSIBLE.
EXPANSION VALVE
4 10
PREPOSITIONED SLEEVE PREPOSITIONED SLEEVE
4 4 10
CORE DRILLED SLEEVE
FOR 1-1/4" AND LARGER
CORE DRILLED SLEEVE
B4
PIPE PENETRATION DETAIL
NTS
CONCRETE STRUCTURE
PIPE SLEEVE SIZED FOR PIPE WITH INSULATION
WATERSTOP
EXTEND SLEEVE 4" ABOVE FINISHED FLOOR LEVEL
MINIMUM 18" LONG ALUMINUM INSULATION JACKET
INSULATION-SEE SPECS FOR THICKNESS
PIPE
SEAL WITH WATERPROOF CAULKING
MINIMUM
" POURED LEAD
MULTI-COMPONENT PLASTIC CEMENT
PIPE SLEEVE (I.D. MIN 1" LARGER THAN O.D. OF
PIPE)
WATERPROOF GROUT
CORE DRILL MIN 1" LARGER HOLE THAN O.D.OF PIPE
SLEEVE
NOTES:
1. SEAL SLEEVE WITH UL RATED SEALANT TO MATCH
RATING OF WALL OR CEILING. MAINTAIN REQUIRED
MINIMUM CONTACT OF SEALANT AND CLEARANCES OF
PIPE IN PENETRATION.
2. PROVIDE ESCUTCHEON PLATES AT ALL EXPOSED
PENETRATIONS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
BID DOCUMENTS
7/29/22
M-601
MECHANICAL SCHEDULES
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
MP
NG
NGMP
NPCW
X
XXX
OFL
OD
RWL
PSD
OFL
OD
RWL
PSD
SS
SD
SS
SSD
TP
TW
V
SINGLE LINE DOUBLE LINE
ABBREVIATION DESCRIPTION
SD
SS
SSD
TP
TW
V
NPHW
NPCW
NPHW
D
DI
DIWS
DIWR
SYMBOL
AV
AW
CA
CND
ABBREVIATION
AV
AW
CA
CW
CD
D
DI
DIWS
DIWR
HW
HWR
MP
NG
NGMP
DESCRIPTION SYMBOL ABBREVIATION DESCRIPTION
PLUMBING SYSTEMS LEGEND PLUMBING SYMBOLS LEGEND PLUMBING GENERAL NOTES
PLUMBING PIPE SYMBOLS LEGEND
HWR
DCW
SS
RAIN WATER OVERFLOW LEADER
OVERFLOW DRAIN
RAINWATER LEADER
PUMPED STORM DRAIN
SANITARY SEWER
STORM DRAIN
SANITARY SEWER
SUB-SOIL DRAIN
TRAP PRIMER WATER
TEMPERED OR TEPID WATER
VENT FOR SANITARY SEWER
NONE POTABLE COLD WATER
NONE POTABLE HOT WATER
ACID VENT
ACID WASTE
COMPRESSED AIR
COLD DOMESTIC WATER
CONDENSATE DRAIN
DRAIN
DEIONIZED WATER
DEIONIZED WATER SUPPLY
DIIONIZED WATER RETURN
HOT DOMESTIC WATER
HOT DOMESTIC WATER RETURN
MEDICAL PRESSURE CONDENSATE
NATURAL GAS
NATURAL GAS MEDIUM PRESSURE
CIRCUIT SETTER VALVE
BALL VALVE
BALANCING VALVE
CHECK VALVE
GATE VALVE
PLAN VIEW
A.F.F. ABOVE FINISHED FLOOR--
ANCHOR
BACKFLOW PREVENTER, REDUCE PRESSURE TYPE
BALL VALVE
BOTTOM CONNECTION
CHECK VALVE
CALIBRATED BALANCING VALVE
CONDENSATION DRAIN & SECONDARY CONDENSATE DRAIN
CONNECT
ENERGY MANAGEMENT CONTROL SYSTEM
EXISTING
FROM ABOVE, FROM BELOW
FLOOR CLEANOUT
FLOOR DRAIN
FLOOR SINK
FLOW ARROW
GATE VALVE
GRADE CLEANOUT
HOSE BIBB
INVERT ELEVATION
LIMIT OF DEMOLITION
NON POTABLE
PIPE BREAK
PIPE CAP
PIPE DOWN
PIPE GUIDE
PIPE UP
POINT OF CONNECTION
ROOF DRAIN AND OVERFLOW
ROUGH-IN AND CONNECT
SHUT OFF VALVE
STRAINER
TO ABOVE, TO BELOW
TRAP PRIMER
VENT, VENT RISER, VENT THRU ROOF
WALL CLEANOUT OR END OF LINE CLEANOUT
WASTE DROP
WATER HAMMER ARRESTOR
WITH
UNDER GROUND
UNION
A.F.F.
A.F.F.
A.F.F.
A.F.F.
A.F.F.
A.F.F.
A.F.F.
A.F.F.
EMCS
(E)
FA,FB
FCO
FD
FS
GCO
HB
IE
POD
NP
POC
RD & OF
RICONN
SOV
TA,TB
TP
V, VR, VTR
WD
WHA
W
UG
TYPICALTYP.
XX
XXX
100-SP-1
DRAWING SYMBOLS
DETAIL NUMBER
DRAWING NUMBER WHERE DRAWN
DEMO KEY NOTE ITEM
DETAIL NUMBER
DETAIL NUMBER
DETAIL NUMBER
DETAIL NUMBER
DETAIL NUMBER
XX
KEY NOTE ITEM
1. KEEP ALL VTR'S MINIMUM 25FT FROM FRESH AIR INTAKES, AND MINIMUM 4FT FROM EXTERIOR WALLS WHETHER SHOWN OR NOT.
2. ALL NEW PIPING SHOWN ON PLUMBING PLAN IS INDICATED AS BOLD LINE TYPE.
3. OFFSET ALL RISERS AND DROPS TO AVOID PENETRATIONS THROUGH TOP PLATES.
4. CONTRACTOR SHALL FIELD VERIFY EXACT SIZES, LOCATIONS AND ELEVATIONS OF ALL PIPING CONNECTIONS AND OTHER WORK PRIOR
TO TRENCHING OR INSTALLING NEW WORK.
5. ALL SHUT-OFF VALVES SHALL BE LINE SIZE UNLESS OTHER WISE NOTED.
6. CONNECT CONDENSATE DRAIN PIPING TO EQUIPMENT WITH P-TRAP. PROVIDE CLEANOUTS AT ALL CHANGE IN DIRECTION.
7. THE DRAWINGS ARE NOT INTENDED TO SHOW EVERY OFFSET OR FITTING OR EVERY STRUCTURAL DIFFICULTY THAT MAY BE ENCOUNTERED DURING INSTALLATION OF THE WORK. LOCATION OF ALL ITEMS NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. EXACT LOCATIONS NECESSARY TO SECURE BEST CONDITIONS AND RESULTS MUST BE DETERMINED AT THE JOB SITE AND SHALL HAVE THE APPROVAL OF THE ARCHITECH BEFORE BEING INSTALLED. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING LOCATIONS OF ITEMS OF WORK. ADJUSTMENTS SHALL BE MADE AS REQUIRED AT NO ADDITIONAL COST TO OWNER.
8. HVAC EQUIPMENT IS SHOWN FOR THE COORDINATION OF UTILITIES ONLY, SEE "MH" SHEETS FOR MORE INFORMATION.
9. FOR APPLICABLE CODES REFER TO ARCHITECTURAL SHEETS.
10. FOR CONDENSATE DRAIN PIPING, DEPTH OF "P" TRAP SHALL BE GREATER THAN THE TTOAL SCHEDULED FAN PRESSURE FOR THE UNIT.
11. OFFSET ALL RISERS AND DROPS TO AVOID STRUCTURAL ELEMENTS. SEAL ALL PENETRATIONS THROUGH FLOOR WATER TIGHT.
12. FIELD VERIFY EXACT SIZES, LOCATIONS AND ELEVATIONS ALL EXISTING PIPING CONNECTIONS SITE AND CLOSELY COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO TRENCHING OR INSTALLING ANY NEW WORK. DRAWINGS ARE DIAGRAMMATIC ONLY.
13. PROVIDE SHUT-OFF VALVES ON DOMESTIC WATER PIPE BRANCHES EQUIPMENT AND ON BRANCHES SERVING TWO OR MORE PLUMBING FIXTURES. WATER PIPING SERVING MAJOR FIXTURE GROUPINGS SUCH AS TOILET ROOMS, SUITES AND THE LIKE SHALL ALSO BE PROVIDED WITH SECTIONALIZING VALVES TO PERMIT SERVICING OR REPLACEMENT OF PIPING, FIXTURES AND EQUIPMENT.
14. COORDINATION SHOP DRAWINGS ARE REQUIRED TO AMPLIFY, EXPAND AND COORDINATE THE INFORMATION CONTAINED IN THE CONTRACT DOCUMENTS. APPROVED SHOP DRAWINGS ARE REQUIRED PRIOR TO THE INSTALLATION OF ALL NEW WORK.
15. ACCESS PANELS SHALL BE PROVIDED WHERE NECESSARY TO PROPERLY ACCESS THE PLUMBING SYSTEM, INCLUDING VALVES.
16. IF APPLICABLE, PROVIDE FLOOR CLEANOUTS IN ALL UNDERGROUND SANITRAY SEWER WASTE AND STORM DRAINS LINES INSIDE THE BUILDING AT EVERY 50FEET AND AT CHANGE OF DIRECTION GRATER THAN 45 DEGREES ACCUMULATIVE, COORDINATE LOCATIONS WITH ARCH PRIOR TO INSTALLATION. ALSO PROVIDE CLEANOUTS AT TOP AND BOTTOM OF ALL STACKS. EXTEND ABOVE THE FLOOR RIM ELEVATION OF ANY FIXTURE LOCATED NEAR THE CLEANOUTS AND BE CONNECTED TO THE SAME WASTE LINE.
17. DOMESTIC HOT WATER UNCIRCULATED LINES BRANCH LINES TO FIXTURES SHALL BE A MAXIMUM OF F FEET TO ALL SENSOR ACTIVATED MIXING STYLE FAUCETS AND A MAXIMUM 15 FEET TO ANY FAUCET WITH CONVENTIONAL CONTROLS.
18. ALL PENETRATIONS OF PIPES, CONDUITS , ETC. THRU RATED ASSEMBLIES SHALL BE FIRE STOPPED. MATERIAL SHALL BE TESTED UL
LISTED ASSEMBLY APPROVED BY THE STATE FIRE MARSHALL.
19. PROVIDE WALL CLEANOUTS AT ALL SINKS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
BID DOCUMENTS
7/29/22
P-001
PLUMBING SYMBOLS &
ABBREVIATIONS
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
A B C E
D
1. DEMO LAVATORY INCLUDING WALL HANGER AND ALL CONNECTED PIPING.
2. DEMO SHOWER FIXTURE AND VALVES INCLUDING ALL CONNECTED PIPING AND
FLOOR DRAIN, SEE P-101 FOR NEW SHOWER FLOOR DRAIN LOCATION.
(NOT ALL KEYED NOTES USED ON THIS SHEET)DEMOLITION KEYED NOTES:
3. DEMO WATER CLOSET, INCLUDING SUPPLY PIPING AND VALVE STOPS.
4. DEMO WATER HEATER, INCLUDING PIPING AND ELECTRICAL CONNECTIONS.
5. DEMO WATER FOUNTAIN, INCLUDING ALL CONNECTED PIPING.
6. DEMO HOSE BIBB
3 4
7. DEMO ALL COLD WATER PIPING BACK TO WATER ENTRY, INCLUDING ALL HOT WATER
PIPING IN BUILDING.
8. WALL HUNG LAVATORY SHALL REMAIN, DEMO FAUCET AND VALVE STOPS.
9. WATER CLOSET SHALL REMAIN, DEMO VALVE STOP AND CONNECTION PIPING TO
WATER CLOSET.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
BID DOCUMENTS
7/29/22
PD101
PLUMBING DEMOLITION FLOOR
PLAN
AutoCAD SHX Text
WATER ENTRY
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
PLUMBING DEMO PLAN
1. NEW LAVATORY AND FAUCET.
2. NEW ADA WATER CLOSET
(NOT ALL KEYED NOTES USED ON THIS SHEET)REMODEL KEYED NOTES:
3. NEW EYE WASH STATION
4. NEW ADA WATER FOUNTAIN
5. NEW ADA SHOWER FIXTURE
6. NEW INSTANTANEOUS ELECTRIC WATER
HEATER
7. NEW BREAK ROOM SINK FIXTURE
8. INSTALL NEW FAUCET, VALVE STOPS AND
FLEX PIPING TO EXISTING LAVATORY.
9. INSTALL NEW VALVE STOPS AND FLEX PIPING
TO EXISTING WATER CLOSET.
10.TRENCH AND INSTALL NEW 2" SANITARY LINE
FOR WATER FOUNTAIN.
11. INSTALL
" CIRCUIT SETTER FOR RECIRC
BRANCH LINE
12.
" MIXING VALVE (MV-1) FOR 85F TEMPERED
WATER.
F D
A B C E
D
EWH-01
CP-01
P-301
P-104
P-707
P-606
P-402
P-701
P-908
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
BID DOCUMENTS
7/29/22
P-101
PLUMBING REMODEL FLOOR PLANS
AutoCAD SHX Text 1/2" 110°
AutoCAD SHX Text
1/2" DCW
AutoCAD SHX Text
1/2" DCW
AutoCAD SHX Text
1/2" DCW
AutoCAD SHX Text
1/2" DCW
AutoCAD SHX Text 1/2" 110°
AutoCAD SHX Text 1/2" 110°
AutoCAD SHX Text 3/4" 110°
AutoCAD SHX Text 1/2" 110°
AutoCAD SHX Text 1/2" 110°
AutoCAD SHX Text
1/2" DCW
AutoCAD SHX Text
1/2" DCW
AutoCAD SHX Text
3/4" DCW
AutoCAD SHX Text
1/2" DCW
AutoCAD SHX Text
3/4" DCW
AutoCAD SHX Text
2"(B) SS
AutoCAD SHX Text 1/2" 110°R
AutoCAD SHX Text 1/2" 110°R
AutoCAD SHX Text 1/2" 110°R
AutoCAD SHX Text 1/2" 110°R
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
PLUMBING REMODEL PLAN
RECIRCULATION PUMP SCHEDULE
MIXING VALVE SCHEDULE
ELECTRIC WATER HEATER SCHEDULE
SYMBOL SERVICE TYPE
CAPACITY
VOLTS/PHASE H.P. MFG. AND MODEL No. REMARKS
CP-1 DHW RECIRC CIRCULATOR
GPM HEAD(FT)
-- -- 120/1 1/40 GOULDS E10-BCANCT1W-23
SYMBOL
DISCHARGE
TEMPERATURE
MAXIMUM
FLOW GPM
PRESURE DROP
@ MAX FLOW
CAPACITY
CW IN HW IN MIXED OUT
MFG. AND MODEL No. REMARKS
SYMBOL
STORAGE
CAPACITY
(GALLONS)
CAPACITY
@ 60°F RISE
(GPM)
POWER REQUIRMENTS
(KW)/VOLTAGE/PHASE
MFG. AND MODEL No. LOCATION REMARKS
EWH-1 -- 2.5 22KW/240V/1PH STATE WATER HEATER/ C4LS-220E SHOP AREA
2"3"
ZURN Z5615, WALL MOUNT, TOP SPUD, ABA COMPLIANT, ELONGATED BOWL. PROVIDE W/ ZURN Z5955SS-EL
OPEN FRONT SEAT, SLOAN ROYAL 111-1.28ES 1.28 GPF SENSORY FLUSH VALVE, SLOAN EL-154
TRANSFORMER, JR SMITH 0417 CARRIER.
WATER CLOSET
(ADA)
P101
- WATTS #LF15M2, LEAD-FREE, 60 PSI AIR PRE-LOAD, PER PDI WH201. PROVIDE W/ ACCESS PANEL.
WATER
HAMMER
ARRESTER
P905
2"
ZURN Z5351, WALL MOUNTED, 19"x17", WHITE VITREOUS CHINA. PROVIDE W/ SLOAN OPTIMA SYSTEM
FAUCET MODEL ETF-80 HARDWIRED SENSOR ACTIVATED, ZURN Z8743-1-PC GRID STRAINER DRAIN, Z8700-PC CHROME PLATED P-TRAP AND TRUEBRO LAV GUARD 2 E-Z MODEL #102E-Z; BRASSCRAFT
REGULAR PART NUMBER SCR39 C REGULAR PATTERN COMPRESSION JOINT ANGLE VALVE WITH LOOSE
KEY, POLYMER BRAID CONNECTORS, AND ESCUTCHEON PLATES
P301 LAVATORY
(ADA)
PLUMBING FIXTURE SCHEDULE
ITEM DESCRIPTION
MINIMUM ROUGH-IN
CONNECTION (INCH)
REMARKSELECTRICAL DATA
CWVW
HW
"1
2"
JUST MFG SLN-ADA-2122, LEDGE MOUNT, STAINLESS STEEL, 21"Lx22"Wx6"D. PROVIDE W/ CHICAGO FAUCET
AGN8AE2805-5CP 0.5 GPM AERATOR GOOSENECK, DUAL WRIST BLADE HANDLE; JUST #J-ADA-35-FS PUNCH
DRAIN AND REMOVABLE STRAINER; CHROME PLATED P-TRAP (HOT WATER SUPPLY AND P-TRAP SHALL BE
TRUEBRO WRAPPED FOR ACCESSIBILITY PROTECTION; BRASSCRAFT COMPRESSION JOINT ANGLE VALVE, POLYMER BRAID CONNECTORS, AND ESCUTCHEON PLATES
P402
BREAKROOM
SINK
P606
DRINKING
FOUNTAIN
HAWS 3602F, DUAL HIGH-LOW, WALL MOUNTED, 304 STAINLESS STEEL CONSTRUCTION. PEDISTAL
MOUNTED, PROVIDE CONCRETE PAD FOR MOUNTING AND WATER FILTER.
2"
P906
TRAP PRIMER
WATTS #WPIME-1, COMPLETE W/ QUARTER-TURN BRASS VALVE AND ENCLOSURE
TRAP
INT
2"
P806
HOSE-BIB
WATTS #SC8-6, HEX SHOULDER W/ TEE HANDLE AND VACUUM BREAKER
P707
EMERGENCY
EYEWASH
HAWS 7261-7271, SCHED 80 PVC GREEN EPOXY FINISH, 316 STAINLESS STEEL BALL VALVE,
ANTI-CORROSIVE, FACE BOWL W/ INTEGRAL FLOW CONTROL AND DUST COVER. PROVIDE W/ SP170 TEST
CARD AND SP178LG FIXTURE SIGNAGE. PROVIDE WITH SCALD PROTECTION BLEED VALVE MODEL SP157A.
3/4"
P701 SHOWER
ZURN Z7200-SS-LH SHOWER VALVE WITH WALL MOUNTING FLANGE, 2.0GPM HAND/WALL SHOWER HEAD 60"
FLEXIBLE HOSE, 24" SLIDE MOUNTING BAR,
" CONNECTIONS. J.R. SMITH FIGURE 2005Y-A05-B-P050-CP,
ROUND ADJUSTABLE STRAINER WITH SEDIMENT BUCKET, CHROME PLATED STRAINER AND TRAP PRIMER
CONNECTION.
2" 2"
2" -
(ADA)
E2
CONDENSATE DRAIN TO DRYWELL DETAIL
NTS
E4
EMER EYEWASH BOUNDARY DETAIL
NTS
E5
EMER EYEWASH PIPING DETAIL
NTS
D2
CONDENSATE DRAIN TRAP PIPING DETAIL
NTS
1. MOUNT BOTTOM OF HEATER 6FT ABOVE FINISHED FLOOR (SIZE= 19"x17"x6")
MV-1 85F 5 10PSI 3.5 1.5 WATTS ES1505.0
1. PROVIDE WITH TIMER
2. HOT WATER SUPPLY TEMP SET AT 110degF (ADJ)
D5
WATER FOUNTAIN DETAIL
NTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
BID DOCUMENTS
7/29/22
P-601
PLUMBING SCHEDULES
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
TRAFFIC WEIGHT CAST IRON OR CONCRETE COVER, FLUSH TO GRADE
AutoCAD SHX Text
DRILL FOR DRAIN
AutoCAD SHX Text
12" MIN CONCRETE PIPE
AutoCAD SHX Text
CRUSHED ROCK- 3/4" TO 1-1/2" AGGREGATE
AutoCAD SHX Text
3/4" DRAIN PIPE
AutoCAD SHX Text %%P12"
AutoCAD SHX Text
3" MIN AIR GAP
AutoCAD SHX Text
36" MIN
AutoCAD SHX Text
MECH EQUIP
AutoCAD SHX Text
3"MIN
AutoCAD SHX Text "A"
AutoCAD SHX Text
TRAP
AutoCAD SHX Text
2%%% SLOPE
AutoCAD SHX Text NOTES: 1. SEE PLAN FOR PIPE SIZES. SEE PLAN FOR PIPE SIZES. 2. INTERIOR CONDENSATE DRAINS ABOVE CEILING SHALL BE INSULATED. INTERIOR CONDENSATE DRAINS ABOVE CEILING SHALL BE INSULATED. 3. IF HORIZONTAL RUN IS GREATER THAN 15FT, INSTALL VENT (SAME SIZE IF HORIZONTAL RUN IS GREATER THAN 15FT, INSTALL VENT (SAME SIZE AS DRAIN PIPE). 4. CONDENSATE DRAIN CONNECTIONS SHALL OCCUR ABOVE EQUIPMENT CONDENSATE DRAIN CONNECTIONS SHALL OCCUR ABOVE EQUIPMENT FRAMING TO ALLOW FOR PROPER P-TRAP INSTALLATION.
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
DRAIN SIZE
AutoCAD SHX Text 1-1/2"
AutoCAD SHX Text 1-1/4"
AutoCAD SHX Text 1"
AutoCAD SHX Text 2"
AutoCAD SHX Text 0-20
AutoCAD SHX Text 21-40
AutoCAD SHX Text 126-250
AutoCAD SHX Text 91-125
AutoCAD SHX Text 41-90
AutoCAD SHX Text
TONS
AutoCAD SHX Text 'B'
AutoCAD SHX Text 'A'
AutoCAD SHX Text TSPx1.5+2"
AutoCAD SHX Text TSPx1.5+2"
AutoCAD SHX Text TSPx0.5+1"
AutoCAD SHX Text TSPx1.5+1"
AutoCAD SHX Text
DRAW THRU
AutoCAD SHX Text
UNIT TYPE
AutoCAD SHX Text
BLOW THRU
AutoCAD SHX Text
TSP = TOTAL STATIC PRESSURE-INCHES
AutoCAD SHX Text "B"
AutoCAD SHX Text
"6" MIN
AutoCAD SHX Text
SPILL CONDENSATE DRAIN PIPING TO DRYWELL
AutoCAD SHX Text
SOLDER ALL JOINTS AS REQUIRED, (TYP)
AutoCAD SHX Text
VENT OPEN TO ATMOSPHERE
AutoCAD SHX Text
LINE CLEANOUT, (TYP)
AutoCAD SHX Text
UNION, (TYP)
AutoCAD SHX Text
DRAIN SIZE AT LEAST SAME SIZE AS NIPPLE CONNECTION SIZE
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text
P707 EMERGENCY EYEWASH
AutoCAD SHX Text
WALL
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
36" MAX.
AutoCAD SHX Text 24"
AutoCAD SHX Text
EXTERIOR WALL
AutoCAD SHX Text
WATER SUPPLY (TEPID)
AutoCAD SHX Text
EXTENSION SPLIT CLAMP PIPE HANGER SECURED TO WALL (TYP 2)
AutoCAD SHX Text
3/4 EXPANSION BOLTS, 4 REQUIRED
AutoCAD SHX Text PROVIDE 2" YELLOW INDUSTRIAL VINYL SAFETY TAPE OR PAINT FOR MINIMUM CLEAR FLOOR SPACE REQUIREMENT.
AutoCAD SHX Text
P707 EMERGENCY COMBINATION EYE/FACEWASH
AutoCAD SHX Text
15" MIN.
AutoCAD SHX Text 6.75"
AutoCAD SHX Text
27" MIN
AutoCAD SHX Text
P606 HIGH/LOW WATER FOUNTAIN
AutoCAD SHX Text 27"
AutoCAD SHX Text CONCRETE PAD, MIN 14"x14"x6"
AutoCAD SHX Text
GRADE LEVEL
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
UTILITY
TRANSFORMER
200A 2P
ELECTRICAL SYMBOLS - DIAGRAM
GENERAL NOTES
A. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING
FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL
REFLECTED CEILING PLAN.
B. LIGHTING FIXTURES WITH MORE THAN TWO LAMPS SHALL
HAVE TWO OUTER LAMPS CONTROLLED WITH ONE SWITCH
AND INNER LAMP(S) CONTROLLED BY A SECOND SWITCH.
C. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN
THREE CIRCUITS. EACH BRANCH CIRCUIT HOMERUN SHALL
HAVE A SEPARATE GREEN INSULATED EQUIPMENT
GROUNDING CONDUCTOR.
D. COORDINATION BETWEEN LOCAL UTILITY AND CONTRACTOR
FOR CUTOVER OF EXISTING SERVICE CONNECTION TO NEW
SERVICE.
E. PANEL B, 240/120VAC, 3W, 200A MAIN BREAKER,
225A BUS, 42 CKTS, SEE SCHEDULE DWG. EP601
F. EMERGENCY LIGHTING UNIT, 90 MINUTES OF ILLUMINATION
UPON LOSS OF POWER, 120V, 20W LITHONIA, NUVO LTG.,
KICHLER OR EQUAL
G. GFCI RECEPTACLE LOCATED 8" ABOVE THE SINK.
H. MOTION SENSING SWITCH, WALL MOUNTED TIMER RANGE 0.5
TO 30 MINUTES(SET TO 20 MINUTES)
I. THE IRRIGATION SYSTEM WILL HAVE TO BE OPERATED
MANUALLY DURING ELECTRICAL WORK
UTILITY
OH SECONDARY
OWNER
SECONDARY
(WEATHER-HEAD)
OWNER
SECONDARY (MAST)
2" RIGID W/ (3) 2/0 AWG CU
UTILITY
METER
EXTERIOR
PANEL A
200A MAIN BREAKER
22kAIC, 240/120V 1ɸ
NEMA 3R CABINET
200A 2P
20A 1P
SINGLE LINE
DIAGRAM
20A 1P
20A 2P
20A 1P 20A 1P
50A 2P
SURGE
PROTECTOR
G N
G N
2" IMC W/
(3) 2/0 AWG &
(1) 1/0 AWG CU
INTERIOR
PANEL B
200A MAIN BREAKER
22kAIC, 240/120V 1ɸ
NEMA 1 CABINET
42 POSITION W/
SURGE SUPPRESSION
N
IMC GENERAL NOTES - DEMOLITION
A. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES,
WIRING DEVICES, CONDUITS, ETC., SHOWN ON PLANS TO BE
REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE AREA OF
WORK PERIMETER AND REMOVE CONDUIT WITHIN THE WORK
AREA, DISCONNECT WIRING AT THE OVERCURRENT
PROTECTIVE DEVICE AND REMOVE WIRING COMPLETELY FROM
THE ABANDONED CONDUITS.
B. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE
OVERCURRENT PROTECTIVE DEVICE. COMPLETELY REMOVE
ALL ABANDONED WIRING.
C. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND
CONDUCTORS PASSING THROUGH RENOVATED AREAS AND
SERVICING UNDISTURBED AREAS.
D. THE IRRIGATION SYSTEM WILL HAVE TO BE OPERATED
MANUALLY DURING ELECTRICAL WORK.
WH
WH
ELECTRICAL SYMBOLS - POWER PLAN
BRANCH CIRCUIT HOMERUN. LINES INDICATE NUMBER OF CIRCUITS,
NEUTRAL, AND SWITCH LEG CONDUCTORS. LONG LINE IS PHASE
SHORT LINE IS NEUTRAL. ONE SEPARATE GREEN GROUNDING
CONDUCTOR SHALL BE PROVIDED FOR EACH HOMERUN; NOT SHOWN
DISTRIBUTION PANEL
DISCONNECT SWITCH - FUSED
TRANSFORMER
WATT-HOUR METER
EARTH GROUND
CIRCUIT BREAKER
RECEPTACLE, DUPLEX
RECEPTACLE, DUPLEX, WITH GROUND
FAULT CIRCUIT INTERRUPTION
SWITCH (# SUBSCRIPT AS INDICATED BELOW):
BLANK = SINGLE POLE 2 = DOUBLE POLE
3 = THREE-WAY 4 = FOUR-WAY
WP = WEATHER PROOF Mo = OCCUPANCY SENSOR
INTERMEDIATE METALLIC CONDUIT
ELECTRICAL SYMBOLS - LIGHTING PLAN
A LIGHT FIXTURE, SURFACE MOUNTED, 610x1220mm (2'x4');
LETTER INDICATES TYPE
A LIGHT FIXTURE, SURFACE MOUNTED, 305x1220mm (1'x4');
LETTER INDICATES TYPE
LIGHTING, TWO HEAD EMERGENCY BATTERY POWER
LIGHTING WALL PACK, EXTERIOR BUILDING
LIGHTING FIXTURE. SURFACE MOUNTED
EXPLOSION PROOF
LIGHTING FIXTURE. SURFACE MOUNTED
COMBINED SMOKE AND CARBON MONOXIDE
DETECTOR
JUNCTION BOX
RECESSED FIXTURE WITH TRIM KIT AND
70W LED IRECTIONAL LAMP
SECURIT CAMERA JUNCTION BOX AND
CAMERA. ARROWS ARE FIELD FO VIEW.
SURFACE MOUNTED EXHAUST FAN
A SURFACE MOUNTED ENCLOSURE (SUBSCRIPT AS INDICATED BELOW)
N = NETWORK W = WATER (SPRINKLER)
ELECTRIC WALL HEATER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
BID DOCUMENTS
E-001
ELECTRICAL SYMBOLS &
ABBREVIATIONS
S
J
C
R
AutoCAD SHX Text S # scott Pen Sion scott Pen a' scott Pen scott Pen r scott Text Box 20220729
TO UTILITY
LIFT POLE
D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION & ROAD REPAIR
PINEVILLE, LA
825CM3013
N/A Project Director
07/29/2022Revisions: Date:
STEPHEN DAVIS
Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: stephen.davis@va.gov Sheet of 53
VCI Project Management Construction Management Engineering
JVSF
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
BID DOCUMENTS
ED101
DEMOLITION PLAN - SERVICE
ENTRANCE
KEY NOTES
DURING ELECTRICAL WORK FROM
DEMOLITION OF EXISTING METERBASE TO
INSTALLATION, AND ENERGIZING NEW METER
BASE, AND INTERNAL WIRING TO IRRIGATION
SYSTEM OPERATE IRRIGATION SYSTEM
MANUALLY
EXISTING CONDUIT TO REMAIN
EXISTING CONDUITS (2) TO REMAIN
EXISTING SECONDARY FROM LOCAL UTILITY
TO BE TRANSFERRED FROM HOUSE KNOB
TO NEW MAST ATTACHMENT TO CONDUIT.
GENERAL NOTES - DEMOLITION
A. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES,
WIRING DEVICES, CONDUITS, ETC., SHOWN ON PLANS TO BE
REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE AREA OF
WORK PERIMETER AND REMOVE CONDUIT WITHIN THE WORK
AREA, DISCONNECT WIRING AT THE OVERCURRENT
PROTECTIVE DEVICE AND REMOVE WIRING COMPLETELY FROM
THE ABANDONED CONDUITS.
B. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE
OVERCURRENT PROTECTIVE DEVICE. COMPLETELY REMOVE
ALL ABANDONED WIRING.
C. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND
CONDUCTORS PASSING THROUGH RENOVATED AREAS AND
SERVICING UNDISTURBED AREAS.
D. DEMOLITION EXISTING METER BASE, SOURCE AND LOAD
CONDUITS, AND GROUNDING.
NORTH
TRUE
NORTH
0' 6" 1' 2' 4'
1" = 1'-0" scott Pen Sion scott Pen a' scott Pen scott Pen r scott
Flammable
Garage 1
Office
Staff Toilet
Garage 2 Garage 3
Public Toilet
Storage
GENERAL NOTES - DEMOLITION
A. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES,
WIRING DEVICES, CONDUITS, ETC., SHOWN ON PLANS TO BE
REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE AREA OF
WORK PERIMETER AND REMOVE CONDUIT WITHIN THE WORK
AREA, DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE
DEVICE AND REMOVE WIRING COMPLETELY FROM THE
ABANDONED CONDUITS.
B. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE
OVERCURRENT PROTECTIVE DEVICE. COMPLETELY REMOVE
ALL ABANDONED WIRING.
C. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND
CONDUCTORS PASSING THROUGH RENOVATED AREAS AND
SERVICING UNDISTURBED AREAS.
IMC
KEY NOTES
1. DEMOLITION EXISTING METER BASE, SOURCE
AND LOAD CONDUITS, AND GROUNDING.
2. EXISTING COMMUNICATIONS ENCLOSURE AND
EQUIPMENT. ENCLOSURE TO BE RELOCATED TO
SOUTH WALL AFTER ELECTRICAL PANEL IS
DEMOLISHED. REROUTE EXISTING CONDUITS.
3. SIEMENS IRRIGATION WATER CONTROL TO BE
RELOCATED ALONG EXISTING WALL AFTER
COMMUNICATING PANEL IS RELOCATED
REROUTE EXISTING CONDUITS
4. DEMOLITION EXISTING BREAKER PANEL AND
BREAKERS
5. DEMOLITION ALL CONDUITS, CONDUCTORS,
JUNCTION BOXES, FIXTURES, SWITCHES,
OUTLETS, AND APPARATUS.
6. THE IRRIGATION SYSTEM WILL HAVE TO BE
OPERATED MANUALLY DURING ELECTRICAL
WORK
N W
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
ALEXANDRIA NATIONAL CEMETERY
MAINTENANCE FACILITY
RENOVATION &…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .