Asbestos Survey - Alexandria Cemetery EH217091 9-24-21.pdf

PDF 1 MB Posted

Attached to
Y1AZ--825CM3013 Alexandria NC Roads and Restroom
Solicitation number
36C78623B0010
Issued by

About this file

This document includes an asbestos survey report and related federal contract opportunity. The asbestos survey report details the results of an inspection of a maintenance building at the Alexandria National Cemetery in Pineville, Louisiana. Asbestos-containing materials were identified including approximately 200 square feet of drywall and joint compound in the bathroom. The report recommends removal of these materials by a licensed asbestos abatement contractor prior to planned renovation due to the quantities exceeding regulatory thresholds.

The related federal contract opportunity is solicitation number 36C78623B0010 for project number 825CM3013 to renovate the maintenance facility and roads at the Alexandria National Cemetery. The solicitation is issued by the Department of Veterans Affairs National Cemetery Administration to complete renovations where asbestos abatement is required according to the survey report.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos Survey Report

Alexandria National Cemetery

Maintenance Building

209 East Shamrock Street

Pineville, Louisiana

September 24, 2021

Terracon Project No. EH217091

Prepared for:

Vali Cooper International

Covington, Louisiana

Prepared by:

Terracon Consultants, Inc.

Baton Rouge, Louisiana

Terracon Consultants, Inc. 2822 O’Neal Lane . Bui ld ing B Baton Rouge, Louisiana 70816

P [225] 344 6052 F [225] 344 6346 terracon.com

September 24, 2021

Vali Cooper International

126 Terra Bella Boulevard, Suite B

Covington, Louisiana 70433

Attn: Mr. Taqi Muhammad

E-mail: Taqi@valiint.com

RE: Asbestos Survey Report

Maintenance Building

209 East Shamrock Street

Pineville, Louisiana 71360

Terracon Project No. EH217091

Dear Mr. Muhammad:

The purpose of this report is to present the results of the services performed at the structure located in the Alexandria National Cemetery at 209 East Shamrock Street, Pineville, Louisiana. The scope of work included a pre-renovation asbestos survey. These services were conducted in general accordance with our proposal PEH217091 dated June 1, 2021. Terracon understands that this survey was requested in preparation for the planned renovation of the structure.

Asbestos-containing materials (ACM) were identified at the subject site. Please refer to the attached report for details.

Terracon appreciates the opportunity to provide this service. If you have any questions regarding this report, please contact the undersigned at (504) 818-3638.

Sincerely, Terracon Consultants, Inc.

Jeremiah Garms Rush Bowers, CIH, CSP

Senior Staff Industrial Hygienist Senior Industrial Hygiene Consultant

Responsive ■ Resourceful ■ Reliable

TABLE OF CONTENTS

1.1 Project Objective

3.1 Visual Assessment

3.2 Physical Assessment

3.3 Sample Collection

3.4 Sample Analysis

5.1 Category II Non-Friable Materials

5.2 Regulated Asbestos Containing Materials

5.3 Recommendations

APPENDIX A – Asbestos Survey Sample Summary

APPENDIX B – Laboratory Analytical Reports

APPENDIX C – Sample Diagram

APPENDIX D – Certifications

Responsive ■ Resourceful ■ Reliable 1

ASBESTOS SURVEY REPORT

Maintenance Building

209 East Shamrock Street

Pineville, Louisiana Terracon Project No. EH217091

September 24, 2021

INTRODUCTION

Terracon Consultants, Inc. (Terracon) conducted an asbestos survey of the maintenance building of the Alexandria National Cemetery located in Pineville, Louisiana. The survey was conducted on

September 20, 2021, by Mr. Lem Dial, a Louisiana Department of Environmental Quality (LDEQ) accredited asbestos inspector. These services were completed in accordance with our proposal

PEH217091 dated June 1, 2021.

1.1 Project Objective

The scope of services included a survey for asbestos-containing materials (ACM) required by the

United States Environmental Protection Agency (USEPA) regulation 40 CFR 61, Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP), and Louisiana

Environmental Regulatory Code (ERC) Title 33, Part III, Section 5151 (Chapter 51), both of which prohibit the release of asbestos fibers to the atmosphere during renovation or demolition activities.

The asbestos NESHAP and Chapter 51 require that potentially regulated asbestos-containing building materials be identified, classified and quantified prior to planned disturbances or demolition/renovation activities.

BUILDING DESCRIPTION

Terracon’s services included an asbestos survey of the interior and exterior of an approximately

1,600-square-foot, concrete slab, single-story structure consisting of brick and concrete masonry construction with shingle roofing material. Terracon was not provided with a date of construction.

FIELD ACTIVITIES

The asbestos survey was conducted by LDEQ accredited asbestos inspector, Mr. Lem Dial. A copy of the asbestos inspector’s certificate is included in Appendix C. The survey was conducted in

Alexandria National Cemetery ■ Pineville, Louisiana

September 24, 2021 ■ Terracon Project No. EH217091

Responsive ■ Resourceful ■ Reliable 5 general accordance with the sample collection protocols established in EPA regulation 40 CFR 763, the Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below.

3.1 Visual Assessment

Our survey activities began with visual observation of the interior and exterior of the building proposed for renovation to identify homogeneous areas of suspect ACM. A homogeneous area consists of building materials that appear similar throughout in terms of color, and texture with consideration given to the date of application. The interior assessment was conducted throughout visually accessible areas of the building. Building materials identified as concrete, glass, wood, masonry, metal or rubber were not considered suspect ACM.

Although reasonable effort was made to survey accessible suspect materials, such as under floor coverings or behind ceilings and walls, additional suspect but un-sampled materials could be located in walls, in voids, or in other concealed areas.

3.2 Physical Assessment

A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material that can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

3.3 Sample Collection

Based on results of the visual observation, bulk samples of suspect ACM were collected in accordance with the sampling protocols outlined in 40 CFR Part 763, Subpart E (AHERA).

Random samples of suspect materials were collected in each homogeneous area. The inspector collected bulk samples using wet methods as applicable to reduce the potential for fiber release.

Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

Nineteen bulk samples were collected from eight homogeneous areas of suspect ACM from the structure. A summary of suspected ACM materials collected during the survey is included as

Appendix A.

3.4 Sample Analysis

Bulk samples were submitted under chain of custody to CA Labs, L.L.C. of Baton Rouge, Louisiana for analysis by polarized light microscopy with dispersion staining techniques per USEPA’s Method

Responsive ■ Resourceful ■ Reliable 6 for the Determination of Asbestos in Bulk Building Materials (600/R-93-116). CA Labs, L.L.C. is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP Accreditation

No. 200772-0) and Louisiana Environmental Laboratory Accreditation Program (LELAP Certificate

No. 03069). The laboratory analytical report is included in Appendix B.

REGULATORY OVERVIEW

The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Under NESHAP, ACM is identified as either friable, Category I non-friable or

Category II non-friable ACM. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. All friable ACM is considered regulated asbestos containing material (RACM).

RACM includes all friable ACM, along with Category I and Category II non-friable ACM that has become friable, will be or has been subjected to sanding, grinding, cutting or abrading, or ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity.

Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes, but is not limited to, cementitious material such as cement pipes, cement siding, cement panels, glazing, mortar and grouts.

The State of Louisiana has established Chapter 27 of the ERC (LAC 33:III.Chapter 27) to regulate the identification, management, and abatement of ACM in schools and state buildings. Chapter

27 requires any asbestos-related activity in a school or state building to be performed by an individual or company accredited by the State of Louisiana, through the LDEQ. An asbestos-related activity consists of the disturbance (whether intentional or unintentional) or abatement of

ACM, the performance of asbestos surveys, the development of management plans and response actions, asbestos project design, the collection or analysis of asbestos samples, monitoring for airborne asbestos or any other activity required to be accredited under Louisiana Department of

Environmental Quality Chapter 27 Appendix A.

In non-state, non-school buildings, the State of Louisiana sets forth emission standards for asbestos under Chapter 51 of the ERC (LAC 33:III.Chapter 51). Per Chapter 51 Section P, the

Responsive ■ Resourceful ■ Reliable 7 following activities, when conducted, must be performed by accredited individuals: asbestos surveys, asbestos abatement, and monitoring for airborne asbestos.

The Louisiana Air Quality Regulations (LAC 33:III.Chapter 51, Subchapter M) require that an inspection be conducted by a person currently accredited as an LDEQ asbestos inspector. LDEQ requires a notification by submitting either an AAC-2 (a) form or AAC-2 (b) form. An AAC 2 (a) form is required when requesting Asbestos Disposal Verification Forms (ADVF) for Asbestos

Contaminated Debris Activities (ACDA), Demolition, Renovation, and/or Response Action projects where Regulated Asbestos Containing Material (RACM) is present, or assumed to be present, above the established thresholds or as otherwise required by LAC 33:III.5151.F.1. The

AAC-2 (a) form must be either postmarked or hand delivered to the Department at least 10 working days prior to the scheduled dates of asbestos removal. An AAC 2 (b) form is required when greater than 64 square feet of Vinyl Asbestos Tile (VAT) is removed without the intent of making it RACM, or when lab analysis of properly sampled materials indicates that no ACM is present; that ACM present is not RACM and will not be made RACM by the demolition; or that all

RACM present is less than established thresholds. The established thresholds per LAC

33:III.5151.F.1 include the combined amount of RACM less than 60 linear feet on pipes, 64 square feet on other facility components or 27 cubic feet of material where length or area could not be measured previously. A Form AAC-2 (b) must be postmarked or hand delivered to the Department at least 5 working days prior to the scheduled date of asbestos removal or 3 working days if the removal only includes resilient floor covering per LAC 33:III.5151.F.2.c.

Any individual or company contracted to perform a demolition or renovation activity that disturbs

RACM in excess of the established thresholds must be recognized by the Louisiana Licensing

Board for Contractors to perform asbestos abatement.

The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The USOSHA standard requires that employee exposure to airborne asbestos must not exceed 0.1 fibers per cubic centimeter of air (0.1 f/cc) as an eight-hour time weighted average (TWA) and not exceed

1.0 fibers per cubic centimeter of air (1.0 f/cc) over a 30-minute time period known as an excursion limit (EL). The TWA and EL are known as USOSHA’s asbestos permissible exposure limits

(PELs). The USOSHA standard classifies construction and maintenance activities that could disturb ACM and specifies work practices and precautions that employers must follow when engaging in each class of regulated work. The standard also specifies requirements for handling materials containing asbestos in concentrations less than or equal to 1%.

Responsive ■ Resourceful ■ Reliable 8

FINDINGS & RECOMMENDATIONS

5.1 Category II Non-Friable Materials

Laboratory analysis confirmed the following asbestos-containing Category II non-friable materials:

◼ Approximately 200 square feet of drywall and joint compound in the Bathroom

According to LDEQ and USEPA NESHAP regulations, Category II nonfriable ACM is any material, excluding Category I nonfriable ACM, that when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material during demolition operations are considered RACM and are required to be abated prior to disturbance or demolition when the total amount of RACM to be disturbed is in excess of established regulatory thresholds.

5.2 Regulated Asbestos Containing Materials

The drywall and joint compound identified in Section 5.1 is considered a Category II nonfriable material in its current condition. However, this material will become friable during demolition or renovation activities. Therefore, the drywall is considered RACM and must be removed by a licensed asbestos abatement contractor prior to renovation or demolition activities that may disturb it.

5.3 Recommendations

Based on the findings of this asbestos survey and the planned renovation scope, Terracon understands the identified ACM will be impacted in quantities in excess of the established regulatory thresholds. Therefore, these materials should be removed and disposed of by a Louisiana-licensed asbestos abatement contractor prior disturbance. This would require that all sections of the AAC-2

(a) Form be completed and submitted to LDEQ prior to renovation or demolition activities and an

Asbestos Disposal Verification Form (ADVF) requested. Upon proper notification, the LDEQ will issue an ADVF to provide approval to begin renovation or demolition activities and to ensure that the ACM is removed and disposed of properly. The AAC-2(a) form must be on site during all RACM removal activities.

Contractors performing renovation work should be advised of the locations of materials containing asbestos and their responsibilities with respect to protection of employee exposures to asbestos found in the OSHA Asbestos standard for construction (29 CFR 1926.1101).

Responsive ■ Resourceful ■ Reliable 9

Terracon recommends preparing specifications for ACM removal. The specifications should include the scope of work, personal protective equipment, work procedures, air monitoring, and documentation.

It should be noted that suspect materials, other than those identified during this survey, may exist within the building. If additional but un-sampled suspect ACMs are revealed during renovation or demolition activities, the materials must be assumed to contain asbestos and treated as such unless sampled by an accredited inspector and laboratory analysis determines otherwise.

A summary of the classification, condition and approximate quantity of each identified ACM is presented in Appendix A. Laboratory analytical reports are presented in Appendix B. Room ID designations, sample locations, and ACM locations are presented in Appendix D.

GENERAL COMMENTS

This asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by Vail Cooper International for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.

APPENDIX A

ASBESTOS SURVEY SAMPLE SUMMARY

TABLE 1.0

Alexandria National Cemetery

Maintenance Building

HA Material Description Material Location Condition Friable?

Sample

Number Lab Results1

NESHAP

Category2

Estimated Quantity of ACM3

1 Carpet with no adhesive Office Good No

01-200-01 Blue Carpet – None Detected

Tan Mastic – None Detected N/A N/A

01-200-02 Blue Carpet – None Detected

Tan Mastic – None Detected

Yellow Insulation with paper

Hot & Cold-Water Supply

Restroom & Bathroom Good No

02-200-03 White Wrap – None Detected

Yellow Fibrous Insulation – None Detected N/A N/A

02-200-04 White Wrap – None Detected

Yellow Fibrous Insulation – None Detected

Drywall & Joint

Compound Bathroom Good No

03-200-05

White Paint White Compound – 2% Chrysotile

White Compound Beneath Tape – 3% Chrysotile

White Drywall with paper – None Detected

CAT II NF

200 square feet

03-200-06 White Paint White Compound – 3% Chrysotile

White Drywall with paper – None Detected 200 square feet

03-200-07

White Paint White Compound – 2% Chrysotile

White Compound Beneath Tape – 3% Chrysotile

White Drywall with paper – None Detected

200 square feet

4 Plaster with skim coat Back Restroom and

Storage Good No

04-200-08 White Paint White Plaster – None Detected

Gray Drywall with Paper – None Detected

N/A N/A 04-200-09 White Paint White Plaster – None Detected

Tan Plaster – None Detected

04-200-10 White Paint White Plaster – None Detected

Tan Mastic – None Detected

5 White Wall Texture Office Good No

05-200-11 White Textured Surfacing – None Detected

N/A N/A 05-200-12 White Textured Surfacing – None Detected

05-200-13 White Textured Surfacing – None Detected

6 Window Glazing Putty Exterior Windows Good No 06-200-14 White Paint White Sealant – None Detected

N/A N/A 06-200-15 White Paint White Sealant – None Detected

1 ND = No asbestos detected in sample 2 RACM = regulated asbestos containing material; Cat I NF = Category I non-friable; CAT II NF = Category II non-friable 3 Estimated quantities are based on a cursory field evaluation, and actual quantities may vary significantly, especially if ACM are present in hidden and/or inaccessible areas not evaluated as part of this survey. LF = linear feet; SF = square feet

TABLE 1.0

Alexandria National Cemetery

HA Material Description Material Location Condition Friable?

Sample

Number Lab Results1

NESHAP

Category2

Estimated Quantity of ACM3

06-200-16 White Paint White Sealant – None Detected

7 Ceramic with grout Bathroom Good No 07-200-17 Blue Ceramic Tile – None Detected N/A N/A

8 Roof Shingles Exterior of building Good No

08-200-18 Black Shingle with Black Gravel - None Detected

Black Felt - None Detected N/A N/A

08-200-19 Black Shingle with Black Gravel - None Detected

Black Felt - None Detected

1 ND = No asbestos detected in sample 1 RACM = regulated asbestos containing material; Cat I NF = Category I non-friable; CAT II NF = Category II non-friable 1 Estimated quantities are based on a cursory field evaluation, and actual quantities may vary significantly, especially if ACM are present in hidden and/or inaccessible areas not evaluated as part of this survey. LF = linear feet; SF = square feet

APPENDIX B

LABORATORY ANALYTICAL REPORTS

Attn:

Customer Project:

Reference #: Date: 9/23/2021

Analysis and Method

Discussion

Qualifications

A "trace asbestos" will be reported if the analyst observes far less than 1% asbestos. CA Labs defines "trace asbestos" as a few fibers detected by the analyst in several preparations and will indicate as such under these circumstances.

Quantification of <1% will actually be reported as <=1% (allowable variance close to 1% is high). Such results are ideal for point counting, and the technique is mandatory for friable samples (NESHAP, Nov. 1990 and clarification letter 8 May 1991) under 1% percent asbestos and the "trace asbestos". In order to make all initial PLM reports issued from CA Labs NESHAP compliant, all <1% asbestos results (except floor tiles) will be point counted at no additional charge.

CA Labs is accredited by the National Voluntary Accreditation Program (NVLAP) for selected test methods for airborne fiber analysis (TEM), and for bulk asbestos fiber analysis (PLM). All analysts have a college degree in a natural science (geology, biology, or environmental science) or are recognized by a state professional board in one these disciplines .Extensive in-house training programs are used to augment education background of the analyst. The group leader of polarized light has received supplemental McCrone Research training for asbestos identification. This report is not covered by the scope of AIHA accreditation. Analysis performed at CA Labs, LLC 12232 Industriplex, Suite 32 Baton Rouge, LA 70809.

Fibrous talc containing samples may even contain a related asbestos fiber known as anthophyllite. Under certain conditions the same fiber may actually contain both talc and anthophyllite (a phenomenon called intergrowth). Again, TEM detection methods are recommended. CA Labs PLM report comments will denote suspected amounts of asbestiform anthophyllite with talc, where further analysis is recommended.

Some samples (floor tiles, surfacings, etc.) may contain fibers too small to be detectable by PLM analysis and should be analyzed by TEM bulk protocols.

Laboratory Analysis Report - Polarized Light

Terracon Consultants Steven Latiolais

524 Elmwood Park Blvd #170

New Orleans, LA 70123 Alexandria National Cemetery

CBR21096330

CA Labs

Dedicated to

Quality

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

NVLAP #200772-0

TDSHS #300370

CDPHE #AL-18111

LELAP #03069

Materials Characterization - Bulk Asbestos Analysis

Summary of polarizing light microscopy (PLM / Stereomicroscopy bulk asbestos analysis) using the methods described in 40CFR Part 763

Appendix E to Subpart E (Interim and EPA 600 / R-93 / 116 (Improved). The sample is first viewed with the aid of stereomicroscopy. Numerous liquid slide preparations are created for analysis under the polarized microscope where identifications and quantifications are preformed. Calibrated liquid refractive oils are used as liquid mouting medium. These oils are used for identification (dispersion staining). A calibrated visual estimation is reported, should any asbestiform mineral be present. Other techniques such as acid washing are used in conjugation with refractive oils for detection of smaller quantities of asbestos. All asbestos percentages are based on calibrated visual estimation traceable to NIST standards for regulated of asbestos. Traceability to measurement and calibration is achieved by using known amounts and types of asbestos from standards where analyst and laboratory accuracy are measured. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 0.50% (well above the laboratory definition of trace).

Vermiculite containing samples may have trace amounts of actinolite-tremolite, where not found be PLM should be analyzed using TEM methods and / or water separation techniques. Suspected actinolite/vermiculite presence will be indicated through the sample comment section of this report.

Labs

A

C

Overview of Project Sample Material Containing Asbestos

Customer Project: Alexandria National Cemetery CA Labs Project #: CBR21096330

White Paint White Compound

White Compound Beneath Tape

Glossary of abbreviations (non-asbestos fibers and non-fibrous minerals):

03-200-07 07-1 White Paint White Compound 2% Chrysotile

07-2

White Compound Beneath

Tape 3% Chrysotile

05-2

White Compound Beneath

Tape 3% Chrysotile

03-200-06 06-1 White Paint White Compound 3% Chrysotile

03-200-05 05-1

This report relates to the items tested. This report is not to be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, AIHA LAP, LLC, or any other agency of the federal government. This report may not be reproduced except in full without written permission from CA Labs. These results are submitted pursuant to CA Labs' current terms and sale, condition of sale, including the company's standard warranty and limitations of liability provisions and no responsibility or liability is assumed for the manner in which the results are used or interpreted. Unless notified in writing to return the samples covered by this report, CA Labs will store the samples for a period of ninety (90) days before discarding. A shipping or handling fee may be assessed for the return of any samples.

ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

White Paint White Compound

Asbestos type / calibrated visual estimate percent

List of Affected Building

Material Types

Sample # Layer

Analysts Physical Description of

Subsample

2% Chrysotile

CA Labs

Dedicated to

Quality

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

NVLAP #200772-0

TDSHS #300370

CDPHE #AL-18111

LELAP #03069

Labs

A

Polarized Light Asbestiform Materials Characterization

Customer Info: Attn: Customer Project:

9/23/2021

4 hr 9/23/2021

Phone #

Fax # EH217092

Laboratory Director

Chris Williams

100% fg

02-200-04 04-1 White Wrap N None Detected 60% ce 40% qu, ma, ot

03-2 Yellow Fibrous Insulation Y None Detected

100% qu, bi

02-200-03 03-1 White Wrap N None Detected 60% ce 40% qu, ma, ot

02-2 Tan Mastic Y None Detected

100% qu, bi

01-200-02 02-1 Blue Carpet N None Detected 90% sy 10% qu, ma

01-2 Tan Mastic Y None Detected

Analyst Alicia Stretz

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

10. TEM analysis suggested

Zo Andriampenomanana Senior Analyst

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116)

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot -other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:

N None Detected 90% sy 10% qu, ma01-200-01 01-1 Blue Carpet

CBR21096330

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type

/ percent

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

NVLAP #200772-0

TDSHS #300370

CDPHE #AL-18111

LELAP #03069

318-787-3269 Date Of Sampling:

Purchase Order #:

Steven Latiolais CA Labs Project #:

Terracon Consultants

Alexandria National Cemetery 524 Elmwood Park Blvd #170

New Orleans, LA 70123 Date:

Turnaround Time: Samples Received:

CA Labs

Dedicated to

Quality

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

Labs

A

9/23/2021

4 hr 9/23/2021

Phone #

Fax # EH217092

Laboratory Director

Chris Williams

Zo Andriampenomanana Senior Analyst

Analyst Alicia Stretz

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116)

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot -other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:

10% ce 90% qu, gy

03-200-07 07-1 White Paint White Compound N 2% Chrysotile

98% qu, mi, bi, ca

N 3% Chrysotile

97% qu, mi, bi, ca

06-2 White Drywall with Paper N None Detected

97% qu, mi, ca

05-3 White Drywall with Paper N None Detected 10% ce 90% qu, gy

05-2

White Compound Beneath

Tape Y 3% Chrysotile

03-200-05 05-1 White Paint White Compound N 2% Chrysotile

98% qu, mi, bi, ca

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type

/ percent

04-2 Yellow Fibrous Insulation Y None Detected 100% fg

318-787-3269 Date Of Sampling:

Purchase Order #:

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

CA Labs Project #:

Terracon Consultants

Alexandria National Cemetery

CBR21096330

524 Elmwood Park Blvd #170

New Orleans, LA 70123 Date:

Turnaround Time: Samples Received:

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

10. TEM analysis suggested

03-200-06 06-1 White Paint White Compound

CA Labs

Dedicated to

Quality

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

NVLAP #200772-0

TDSHS #300370

CDPHE #AL-18111

LELAP #03069

Steven Latiolais

Labs

A

9/23/2021

4 hr 9/23/2021

Phone #

Fax # EH217092

Laboratory Director

Chris Williams

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

10. TEM analysis suggested

Zo Andriampenomanana Senior Analyst

Analyst Alicia Stretz

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116)

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot -other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:

100% qu, ma, ca

04-200-10 10-1 White Paint White Plaster N None Detected

100% qu, ma, bi, ca

09-2 Tan Plaster Y None Detected

10% ce 90% qu, gy

04-200-09 09-1 White Paint White Plaster N None Detected

100% qu, ma, bi, ca

08-2 Gray Drywall with Paper N None Detected

10% ce 90% qu, gy

04-200-08 08-1 White Paint White Plaster N None Detected

100% qu, ma, bi, ca

07-3 White Drywall with Paper N None Detected

Non-asbestos fiber type / percent

Non-fibrous type

/ percent

07-2

White Compound Beneath

Tape Y 3% Chrysotile 97% qu, mi, ca

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Turnaround Time: Samples Received:

318-787-3269 Date Of Sampling:

Purchase Order #:

CA Labs

Dedicated to

Quality

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

NVLAP #200772-0

TDSHS #300370

CDPHE #AL-18111

LELAP #03069

Steven Latiolais CA Labs Project #:

Terracon Consultants

Alexandria National Cemetery

CBR21096330

524 Elmwood Park Blvd #170

New Orleans, LA 70123 Date:

Labs

A

9/23/2021

4 hr 9/23/2021

Phone #

Fax # EH217092

Laboratory Director

Chris Williams

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

10. TEM analysis suggested

Zo Andriampenomanana Senior Analyst

Analyst Alicia Stretz

2% wo

98% qu, ma, bi, ca

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116)

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot -other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:

06-200-16 16-1 White Paint White Sealant N None Detected

2% wo

98% qu, ma, bi, ca

06-200-15 15-1 White Paint White Sealant N None Detected 2% wo

98% qu, ma, bi, ca

06-200-14 14-1 White Paint White Sealant N None Detected

5% wo

95% qu, mi, bi, ca

05-200-13 13-1 White Textured Surfacing N None Detected 5% wo

95% qu, mi, bi, ca

05-200-12 12-1 White Textured Surfacing N None Detected

100% qu, ma, ca

05-200-11 11-1 White Textured Surfacing N None Detected 5% wo

95% qu, mi, bi, ca

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type

/ percent

10-2 Tan Plaster Y None Detected

318-787-3269 Date Of Sampling:

Purchase Order #:

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Terracon Consultants

Alexandria National Cemetery

CBR21096330

524 Elmwood Park Blvd #170

New Orleans, LA 70123 Date:

Turnaround Time: Samples Received:

CA Labs

Dedicated to

Quality

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

NVLAP #200772-0

TDSHS #300370

CDPHE #AL-18111

LELAP #03069

Steven Latiolais CA Labs Project #:

Labs

A

9/23/2021

4 hr 9/23/2021

Phone #

Fax # EH217092

Laboratory Director

Chris Williams

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

10. TEM analysis suggested

Zo Andriampenomanana Senior Analyst

Analyst Alicia Stretz

40% ce 60% qu, bi

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116)

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot -other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:

19-2 Black Felt Y None Detected

40% ce 60% qu, bi

08-200-19 19-1 Black Shingle with Black Gravel N None Detected 15% fg 85% qu, bi

18-2 Black Felt Y None Detected

100% qu, ma, ot

08-200-18 18-1 Black Shingle with Black Gravel N None Detected 15% fg 85% qu, bi

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type

/ percent

07-200-17 17-1 Blue Ceramic Tile N None Detected

318-787-3269 Date Of Sampling:

Purchase Order #:

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Terracon Consultants

Alexandria National Cemetery

CBR21096330

524 Elmwood Park Blvd #170

New Orleans, LA 70123 Date:

Turnaround Time: Samples Received:

CA Labs

Dedicated to

Quality

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

NVLAP #200772-0

TDSHS #300370

CDPHE #AL-18111

LELAP #03069

Steven Latiolais CA Labs Project #:

Labs

A

APPENDIX C

SAMPLE DIAGRAM

THIS DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES

LEGEND

NOT TO SCALE

DRYWALL

Drawn By:

Checked By:

Approved By:

Project Mngr:

File No.

Date:

Scale:

Project No.

Consulting Engineers and Scientists

EXHIBITSAMPLE LOCATION DIAGRAM

ASBESTOS SURVEY

ALEXANDRIA NATIONAL CEMETERY

200 EAST SHAMROCK STREET

PINEVILLE, LOUISIANA

JG

SEG

MRF/JG

LN

EH217092

AS SHOWN

ASEH217092-1

SEPTEMBER 2021 2822 O'Neal Lane, Building B Baton Rouge, LA 70816

(225) 344-6052 (225) 344-6346

SAMPLE LOCATION

RESTROOM STORAGE

EQUIPMENT

STORAGE

OFFICE

BATHROOM

STORAGE

18 15

08 10

SHOWER

AutoCAD SHX Text N

APPENDIX D

CERTIFICATIONS

Final Drawing - Maintenance Building
Sheets and Views
Model

cbr21096330-asb lab results

2021-09-24T15:47:48-0500
Nunez, Lucio
2021-09-24T14:54:07-0600
Bowers, J. Rush

File details come from the government source that posted it. Updated .