This document contains the results of a lead-containing paint inspection report for the maintenance building at Alexandria National Cemetery in Pineville, Louisiana. Terracon Consultants conducted limited lead paint sampling at five locations on the building in preparation for planned renovations. Samples were taken from various building components and substrates and analyzed by EMSL Analytical, with results ranging from less than 1% to 4.1% lead by dry weight. The related federal contract opportunity is solicitation number 36C78623B0010 for renovations to the maintenance facility and roads at Alexandria National Cemetery, issued by the Department of Veterans Affairs National Cemetery Administration. Work will include renovations to address the lead-containing paint identified in the inspection report.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Terracon Consultants, Inc. 2822 O’Neal Lane, Bui ld ing B Baton Rouge, Louisiana 70816

P (225) 239 2636 terracon.com

October 6, 2021

Vali Cooper International 126 Terra Bella Boulevard, Suite B

Covington, LA 70433

Attn: Mr. Taqi Muhammad P: (504) 378-7399 E: Taqi@valiint.com

Re: Lead-Containing Paint Inspection Report Alexandria National Cemetery - Maintenance Building 209 East Shamrock Street Pineville, LA 71360 Terracon Project No. EH217092

Dear Mr. Muhammad:

Terracon Consultants, Inc. (Terracon) conducted limited lead paint sampling at the subject property located at 209 East Shamrock Street in Pineville, Louisiana on September 20, 2021.

The sampling was conducted in general accordance with Terracon’s Proposal Number

PEH217092 dated May 21, 2021. Terracon understands that this survey was requested due to the planned renovation of the maintenance building.

Project Information

Limited lead paint chip sampling was performed on September 20, 2021, by Mr. Lem Dial, a

Terracon professional under the direction of Jeremiah Garms, an LDEQ Lead Risk Assessor

(AI#: 140570). Our scope of services included the collection of bulk paint chip samples of suspect lead-containing paint prior to the planned renovations of the Alexandria National Cemetery

Maintenance Building. The disturbance of lead-containing paints as it relates to this project is regulated by the Occupational Safety and Health Administration (OSHA) for employee exposure.

Findings

Terracon’s Lead Risk Assessor identified five potential combinations of building component, substrate, and paint color where lead-containing paint could be present. As a result, five paint bulk chips were collected from various building components and were submitted under chain of custody to EMSL Analytical, Inc. of Cinnaminson, New Jersey for total lead analysis by EPA method (SW 846 3050B/7000B - Flame AAS). EMSL Analytical, Inc. is accredited by the

Louisiana Environmental Laboratory Accreditation Program (LELAP; Certification No. 01950). The results of the sample analysis ranged from less than (<)0.0080% to 0.65% lead by weight (wt).

The following table provides a summary of the results. The laboratory analytical report is included as Appendix A and selective photographs are presented in Appendix B.

Limited Paint Sampling Results 209 East Shamrock Street ■ Pineville, Louisiana October 6, 2021 ■ Terracon Project EH217092

Responsive ■ Resourceful ■ Reliable 2

Table 1 – Summary of Lead Content in Paint

Sample Number Component Substrate Color Lead

Concentration

200 - 01 Interior Wall Concrete Grey <0.032% wt

200 - 02 Exterior Wall / Gutters Wood / Metal White 0.65 % wt

200 – 03 Interior Wall Sheetrock Cream <0.0080% wt

200 – 04 Interior Wall Brick White 0.017 % wt

200 – 05 Wall/Ceiling Plaster Cream <0.0080% wt

The results indicate that lead was detected in the white paint on the exterior wood walls & white gutters of the building and the white paint on the interior brick walls. These areas should be considered for abatement or stabilization. The analytical report is presented as Appendix A.

The Occupational Safety and Health Administration (OSHA) regulates lead in construction work in any concentration because it may be possible to generate significant airborne lead concentrations when performing certain work on materials containing lead.

Recommendations

Any detectable level of lead presents a potential source of exposure with regard to the OSHA

Lead in Construction Standard (29 CFR 1926.62). OSHA defines lead-containing paint as a paint that contains lead, regardless of the concentration.

Therefore, Terracon recommends that maintenance personnel and any potential contractors be made aware of the findings of this limited lead-containing paint survey. Maintenance personnel and contractors should follow the requirements of the OSHA Lead in Construction standard when disturbing lead-containing components. The full OSHA lead standard should be referenced for compliance.

All occupational exposure to lead occurring during construction work, including maintenance activities, painting, alteration and repairs is subject to the OSHA Lead Exposure in Construction standard. Construction work covered by 29 CFR 1926.62 includes any repair or renovation activities or other activities that disturb in-place lead-containing materials, but does not include routine cleaning and repainting where there is insignificant damage, wear, or corrosion of existing lead-containing coatings or substrates. Employers must assure that no employee will be exposed to lead at concentrations greater than 50 micrograms per cubic meter averaged over an eight-hour period without adequate protection.

The landfill selected to receive the waste stream should be contacted to determine specific disposal requirements prior to transportation.

Responsive ■ Resourceful ■ Reliable 3

General Comments

Limited lead paint sampling activities were conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during limited sampling event. This letter report has been prepared on behalf of and exclusively for use and reliance by the Client. This report is not a bidding document. Contractors or consultants reviewing this limited sampling report must draw their own conclusions regarding further investigation or remediation deemed necessary.

Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information, which may have been used in the preparation of this report. No warranty, express or implied is made.

The above overview is not intended to be inclusive of all potentially pertinent regulatory information. The relevant EPA and OSHA standards should be consulted prior to undertaking activities involving the demolition, renovation, or maintenance of surfaces coated with lead-based paints. Limited lead-based paint sampling is not intended to serve as a comprehensive building lead-based paint survey, comprehensive inspection, or comprehensive assessment for the presence of lead-based paint on all or most of the building systems.

Terracon appreciates the opportunity to provide this service to Vali Cooper International. If you have any questions regarding this sampling report, please contact the undersigned at (225) 239-

2636.

Sincerely, Prepared By: Reviewed By:

Jeremiah Garms Rush Bowers, CIH, CSP

LDEQ Lead Risk Assessor (AI#: 140570) Senior Industrial Hygiene Consultant

Attachments:

Exhibit 1 – Sample Locations Diagram

Appendix A – Laboratory Analytical Reports

Appendix B – Certifications

THIS DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES

LEGEND

NOT TO SCALE

Drawn By:

Checked By:

Approved By:

Project Mngr:

File No.

Date:

Scale:

Project No.

Consulting Engineers and Scientists

EXHIBITSAMPLE LOCATION DIAGRAM

LBP SURVEY

ALEXANDRIA NATIONAL CEMETERY

200 EAST SHAMROCK STREET

PINEVILLE, LOUISIANA

JG

SEG

MRF/JG

LN

EH217092

AS SHOWN

ASEH217092-1

SEPTEMBER 2021 2822 O'Neal Lane, Building B Baton Rouge, LA 70816

(225) 344-6052 (225) 344-6346

SAMPLE LOCATION

RESTROOM STORAGE

EQUIPMENT

STORAGE

OFFICE

BATHROOM

STORAGE

200-04

200-03

200-05

200-02

200-01

SHOWER

AutoCAD SHX Text N

Responsive ■ Resourceful ■ Reliable 4

APPENDIX A

Client Sample Description ConcentrationLab ID Analyzed Weight Lead

Collected

EMSL Analytical, Inc.

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com

Attn: Lem Dial Terracon Consultants 524 Elmwood Park Blvd.

Ste. 170 New Orleans, LA 70123

Received: 9/23/2021 11:15 AM

EH217092

Fax:

Phone: (504) 818-3638

Project:

9/20/2021Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

202107248 CustomerID: TCNL25 CustomerPO: EH217091 ProjectID:

EMSL Order:

0.0619 Site: grey on interior concrete

202107248-0001200-01 <0.032 % wt9/23/2021 g9/20/2021

0.2504 Site: white exterior wood

202107248-0002200-02 0.65 % wt9/23/2021 g9/20/2021

0.2602 Site: cream interior drywall

202107248-0003200-03 <0.0080 % wt9/23/2021 g9/20/2021

0.2553 Site: white interor brick walls

202107248-0004200-04 0.017 % wt9/23/2021 g9/20/2021

0.2538 Site: cream interior plaster walls / ceilings

202107248-0005200-05 <0.0080 % wt9/23/2021 g9/20/2021

Phillip Worby, Lead Laboratory Manager or other approved signatory

Test Report ChmSnglePrm/nQC-7.32.3 Printed: 9/23/2021 4:35:40 PM

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01

Initial report from 09/23/2021 16:35:40 http://www.EMSL.com mailto:cinnaminsonleadlab@emsl.com

Responsive ■ Resourceful ■ Reliable 5

APPENDIX B

STATE OF LOUISIANA

DEPARTMENT OF ENVIRONMENTAL QUALITY

certifies that

Jeremiah A Garms

Has complied with all requirements of the Louisiana Department of Environmental Quality and is authorized to perform the duties of

Lead Risk Assessor

Accreditation No. MR140570 AI No. 140570

Date of Issuance April 30, 2021 Expiration March 3, 2022

Failure to comply with all applicable provisions of La. R.S. 2025.E. (1)(a) and La. R.S. 2025.F. (2)(a) may result in civil and/or criminal enforcement actions by the State.

Public Participation & Permit Support Division

Office of Environmental Services

Lead Risk Assessor LDEQ Jeremiah A Garms 140570
LBP DIagram
Sheets and Views
Model

202107248_002 LBP Lab Report

2021-10-06T16:45:01-0500
Nunez, Lucio
2021-10-06T17:04:41-0500
Whitting, Steve E

File details come from the government source that posted it. Updated .