DRAWINGS
7 MB Posted
- Solicitation number
- 22-FAC-016
- Issued by
- Douglas County, Georgia
About this file
This is a comprehensive set of mechanical and plumbing design drawings for the Morningside Elementary School HVAC and Plumbing Upgrades project located at 120 Sunset Lane, Albany, Georgia 31705 (GA DOE ID #2058). The project scope encompasses the complete replacement and upgrade of heating, ventilation, air conditioning, and plumbing systems throughout the facility. The work includes removal and installation of wall-hung heat pumps (20 units), rooftop units (8 units), exhaust fans (12 units), ceiling heaters (10 units), ductless indoor units (8 units), heat recovery units, and associated ductwork, piping, and controls. The project is organized into five construction phases to minimize disruption to school operations, with provisions for relocating up to six classrooms per phase to temporary modular units. The design includes new equipment support platforms, concrete pads, roof curbs, and architectural modifications such as new ceiling chases and bulkheads to conceal ductwork. All existing R-22 refrigerant must be recovered by the mechanical contractor during demolition for owner processing.
The drawings specify equipment from Carrier as the basis of design, including variable refrigerant flow (VRF) systems, 100% outside air handling units with DX cooling coils, and ductless split-system heat pumps with R-410A refrigerant. The project requires installation of duct insulation, condensate drainage systems with traps and supports, fire and smoke dampers, motorized dampers, and building automation system integration. Specific details are provided for equipment installation, including wall-mounted units requiring integral bi-polar ionization units for indoor air quality, duct penetrations through walls and floors with sleeves and lintels, and roof-mounted equipment with curb adapters and concrete pads. The contractor must coordinate with existing building systems, field verify all dimensions and conditions, and provide protective measures for occupied areas during construction. The drawings indicate requirements for accessibility, maintenance clearances, and compliance with manufacturer specifications for refrigerant piping, condensate drainage, and electrical connections.
Text of this file
D A
D E
BLECKLEY LAURENS
CHATHAM
EFFINGHAM
IRWIN
BERRIEN
LOWNDESGRADY
SE
MI
NO
LE
DECATUR
EARLY
MILLER
BAKER
THOMAS
BROOKS
COLQUITT
MITCHELL
COOK
TIFT
SCHLEY
TERRELL
DOUGHERTY
WEBSTER
RANDOLPH
QUITMAN
CLAY
CALHOUN
CHATTAHOOCHEE
STEWART
MARION
WILCOX
CRISP
WORTH
LEE
TURNER
DOOLY
MACON
SUMTER
HOUSTON
PULASKI
McINTOSH
PIERCE
CHARLTON
LA
NIE
R
CLINCH
ECHOLS
ATKINSON
WARE
CAMDEN
BRANTLEY
GLYNN
TOOMBS
APPLING
COFFEE
BEN HILL
TELFAIR
DAVIS
JEFF
WHEELER
DODGE
TREUTLEN
M
ON
TG
OM
ER
Y
LONG
WAYNE
LIBERTY
BULLOCH
EVANS
CANDLER
TATTNALL
BRYAN
DAWSON FRANKLIN
CLARKE
OCONEE
PUTNAM
BALDWIN
TWIGGS
HENRY
FA
YE
TT
E
PIKE
UPSON
SPALDING
M
ER
IW
ET
HER
HARRIS
MUSCOGEE
TALBOT
COWETA
HEARD
TROUP
PEACH
CRAWFORD
TAYLOR
BIBB
MONROE
LAMAR
BUTTS
JASPER
JONES
CHEROKEE
FULTON
PAULDING
HARALSON
CARROLL
DOUGLAS
BARTOWFLOYD
POLK
COBB
NEWTON
DEKALB
CL
AY
TO
N
ROCKD
AL
E
WALTON
MORGAN
GWINNETT
FORSYTH
JACKSON
HALL BANKS
BARROW
M cD
U F
FI
E
JEFFERSON
EMANUEL
WASHINGTON
WILKINSON
JOHNSON
HANCOCK
WARREN
GLASCOCK
JENKINS
SCREVEN
RICHMOND
BURKE
COLUMBIA
OGLETHORPE
WILKES
TALIAFERROGREENE
LINCOLN
ELBERT
HART
MADISON
RABUN
STEPHENS
FANNIN
PICKENS
GILMER
WHITF
IELD
GORDON
C H
AT
TO
O G
A
WALKER M
U
R R
AY
CATOOSA
UNION
LUMPKIN
WHITE
HABERSHAM
TOWNS
BACON
DOUGHERTY
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
INDEX OF DRAWINGS GEORGIA/COUNTY MAP PROJECT LOCATION
GA DOE ID #: 2058
T100
TITLE SHEET
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
MORNINGSIDE ELEMENTARY SCHOOL - HVAC
& PLUMBING UPGRADES
120 SUNSET LN, ALBANY, GA 31705
T100 TITLE SHEET
C100 SITE PLAN
A100 CONSTRUCTION PHASING PLAN
A200 ARCHITECTURAL CEILING PLAN - OVERALL
A300 ARCHITECTURAL CHASE PLAN & DETAILS
MD100 MECHANICAL DUCT DEMO OVERALL PLAN
MD101 MECHANICAL DEMO PLAN - SECTOR A & C
MD102 MECHANICAL DEMO PLAN - SECTOR B
MD103 MECHANICAL DEMO PLAN - SECTOR D & E
M100 MECHANICAL NEW WORK OVERALL PLAN
M101 MECHANICAL NEW WORK PLAN - SECTOR A & C
M102 MECHANICAL NEW WORK PLAN - SECTOR B
M103 MECHANICAL NEW WORK PLAN - SECTOR D & E
M301 PIPING/WIRING DIAGRAMS
M501 MECHANICAL DETAILS
M502 MECHANICAL DETAILS
M503 MECHANICAL DETAILS
M601 MECHANICAL SCHEDULES
M602 MECHANICAL SCHEDULES, LEGEND & GENERAL NOTES
P101 PLUMBING FLOOR PLAN
P102 PLUMBING PLAN - SECTOR B & C
P103 PLUMBING FLOOR PLANS - SECTOR D & E
P104 PLUMBING ROOF PLAN
E001 ELECTRICAL OVERALL PLAN
ED101 ELECTRICAL DEMOLITION PLAN - SECTOR A & C
ED102 ELECTRICAL DEMOLITION PLAN - SECTORS B
ED103 ELECTRICAL DEMOLITION PLAN - SECTOR D & E
E101 ELECTRICAL NEW WORK PLAN - SECTOR A & C
E102 ELECTRICAL NEW WORK PLAN - SECTORS B
E103 ELECTRICAL DEMOLITION PLAN - SECTOR D & E
E801 ELECTRICAL SCHEDULES & LEGEND
No. Description Date
GA DOE ID #: 2058
TREE
TREE
TREE
TREE
TREE
TREE
TREE
VERIFY LOCATIONS OF OTHER TREES IN
THIS AREA
EXISTING PORTABLE
FENCE
FENCE FENCE
PARKING LOT
CONTRACTOR SHALL COORDINATE WITH OWNER FOR TEMPORARY
CONNECTION OF 2" DOMESTIC COLD WATER PIPING TO EXISTING IN
THIS APPROXIMATE LOCATION BELOW GRADE.
2" DCW
D C
W
2" DCW 1 1/2" DCW
1 1/2" DCW
1 1/2" DCW
1 1/2" DCW
GENERAL NOTE: LOCATIONS OF CLASSROOM TRAILERS IS APPROXIMATE.
CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF EXISTING STORM DRAINS, FENCING,
SIDEWALKS, PLAYGROUNDS, DRIVES, ETC. AND CAREFULLY COORDINATE PLACEMENT
OF CLASSROOMS TO AVOID CONFLICT AND MAINTAIN REQUIRED CLEARANCES.
TEMPORARY PORTABLE CLASSROOM
TEMPORARY PORTABLE CLASSROOM
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
C101
SITE PLAN
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/16" = 1'-0"1 SITE PLAN
TREE
TREE
TREE
TREE
TREE
TREE
VERIFY LOCATIONS OF OTHER TREES IN
THIS AREA
EXISTING PORTABLE
(NOT IN SCOPE)
FENCE
FENCE FENCE
PARKING LOT
TEMPORARY PORTABLE CLASSROOM
TEMPORARY PORTABLE CLASSROOM
PHASE 2GYMNASIUM
CLASSROOM
COMPUTER LAB
CLASSROOM
COMPUTER LAB
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
MECHANICAL
99 GIRLS
BOYS
CORRIDOR
BOYS
GIRLS
CLASSROOM
60CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
ART CENTER
MUSIC ROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
88 CLASSROOM
CLASSROOM
COMPUTER LAB
COMPUTER LAB
STOR.
COACHES OFFICE
TOIL.
BOYS
49 GIRLS
JAN.
TOIL.
CORRIDOR
CORRIDOR
STOR.
STOR.
ELEC
TOIL.
STORAGE
STORAGE
CNSLR.
TOIL.
MEDIA PRODUCTION
MEDIA CENTER
VAULT
ASST. PRINC.
MECHANICAL
TOIL.
CORRIDOR
STAFF LOUNGE
TOIL.
PRINC.
MEDIA CTR. DIRECTOR
WORKROOM
TOIL.
TOIL.
FOOD STORAGE
LOCKERS
OFFICE
VEST.
JAN.
COOLER
FREEZER
KITCHEN
GIRLS
BOYS
BOOK STORAGE
WORK ROOM
30CORR.
CONFERENCE
CORRIDOR
CORR.
STOR.
STOR.
STOR.
BOYS
GIRLS
STAGE
CAFETERIA
CORRIDOR
RECEPTIONIST
AV STORAGE
CAN WASH
DISH WASH
JAN.
JAN.
ENTRY
WAITING
PHASE 1
PHASE 3
PHASE 4
PHASE 5
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
GA DOE ID #: 2058
A100
CONSTRUCTION PHASING
PLAN
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/16" = 1'-0"1 CONSTRUCTION PHASING PLAN
GENERAL NOTE: THERE WILL BE 3 MODULAR CLASSROOM BUILDINGS WITH (2) CLASSROOMS PER MODULAR UNIT ON THIS SITE PROVIDED BY THE CONTRACTOR. NO MORE THAN 6 CLASSROOMS MAY BE MOVED TO MODULAR UNITS FOR EACH PHASE. PHASES SHOWN HEREIN ARE SUGGESTED PHASES AND MAY BE CHANGED DUE TO CONSTRUCTION TIMELINES, CONSTRUCTION SCHEDULES, EQUIPMENT
LEAD TIMES, UNFORESEEN CIRCUMSTANCES ENCOUNTERED DURING THE CONSTRUCTION PROCESS
OR FURTHER COORDINATION WITH OWNER. VERIFY ALL PHASING, TEMPORARY WALL/PARTITION
INSTALLATION AND/OR SCHEDULING PRIOR TO COMMENCEMENT OF WORK.
NOTES: (THIS SHEET ONLY)
1 . ADJUST TEMPORARY WALLS AS REQUIRED TO MAINTAIN
SEPARATION FROM WORK AREAS AND OCCUPIED STUDENT
AREAS. ACCESS TO EXIT DOORS SHALL BE MAINTAINED AT
ALL TIMES.
2 . ADJUST TEPROVIDE TEMPORARY WALL (MIN 6' TALL) TO
SEPARATE WORK AREAS FROM OCCUPIED AREAS BASED ON
PHASING. PROVIDE DOORS AS REQUIRED FOR ACCESS TO
WORK AREA. PROVIDE PROTECTION FOR EXISTING
FLOORING, WALLS, ETC. TO PREVENT DAMAGE TO EXISTING
ITEMS DURING INSTALLATION / REMOVAL OF TEMPORARY
WALL.MPORARY WALLS AS REQUIRED TO ALLOW ACCESS TO
RESTROOMS WHILE MAINTAINING SEPARATION OF WORK
AREAS FROM OCCUPIED STUDENT AREAS.
3 . ADJUST TEMPORARY WALLS AS REQUIRED TO ALLOW
ACCESS TO RESTROOMS WHILE MAINTAINING SEPARATION
OF WORK AREAS FROM OCCUPIED STUDENT AREAS.
No. Description Date
GENERAL NOTE: PRIOR TO CONSTRUCTION, CONTRACTOR SHALL COORDINATE
WITH OWNER TO REMOVE ALL PERSONAL ITEMS FROM SPACES AFFECTED BY
DEMOLITION. CONTRACTOR SHALL PROTECT EXISTING CASEWORK, FURNITURE,
FLOORING, WALLS, CEILINGS, ETC. NOT ABLE TO BE REMOVED. AT THE END OF
CONSTRUCTION, CONTRACTOR SHALL REMOVE ALL PROTECTIVE COVERS AND
WIPE DOWN AND CLEAN ALL SURFACES AFFECTED BY DUST, DIRT,
CONSTRUCTION DEBRIS, ETC.
UP
KITCHEN
CAFETERIA
GENERAL NOTE: REMOVAL OF CEILINGS REQUIRED FOR
REMOVAL OF EXISTING EXHAUST FANS LOCATED ABOVE
RESTROOMS NOT SHOWN. SEE MECHANICAL DRAWINGS
FOR LOCATIONS OF ITEMS LOCATED ABOVE CEILINGS THAT
MAY REQUIRE REMOVAL OF CEILING TILES.
GYMNASIUM
CLASSROOM
COMPUTER LAB
CLASSROOM
COMPUTER LAB
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
MECHANICAL
GIRLS
BOYS
CORRIDOR
BOYS
GIRLS
CLASSROOM
60CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
ART CENTER
MUSIC ROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
88 CLASSROOM
CLASSROOM
COMPUTER LAB
COMPUTER LAB
STOR.
COACHES OFFICE
TOIL.
BOYS
49 GIRLS
JAN.
TOIL.
CORRIDOR
CORRIDOR
STOR.
STOR.
ELEC
TOIL.
STORAGE
STORAGE
CNSLR.
TOIL.
MEDIA PRODUCTION
MEDIA CENTER
VAULT
ASST. PRINC.
MECHANICAL
TOIL.
CORRIDOR
STAFF LOUNGE
TOIL.
PRINC.
MEDIA CTR. DIRECTOR
WORKROOM
TOIL.
TOIL.
FOOD STORAGE
LOCKERS
OFFICE
VEST.
JAN.
COOLER
FREEZER
GIRLS
BOYS
BOOK STORAGE
WORK ROOM
30CORR.
CONFERENCE
CORRIDOR
CORR.
STOR.
STOR.
STOR.
BOYS
GIRLS
STAGE
CORRIDOR
RECEPTIONIST
AV STORAGE
CAN WASH
DISH WASH
JAN.
JAN.
ENTRY
WAITING
CEILING IN STOR.
36 WILL NOT BE
REPLACED.
DEMO EXISTING CEILING TILE & GRID AS
REQUIREDAND REPLACE WITH NEW CEILING
TILE & GRID
DEMO EXISTING CEILING TILE &
REPLACE WITH NEW CEILING TILE
CEILING HATCH LEGEND
(NO HATCH) EXISTING CEILING TILE
& GRID TO REMAIN
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
A200
ARCHITECTURAL CEILING
PLAN - OVERALL
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/16" = 1'-0"1 ARCHITECTURAL CEILING PLAN - OVERALL
1 1 1 1 1
1 1 1 1 1
1 1 1
1 LAYER ABUSE RESISTANT 5/8" GYPSUM BOARD (ONE SIDE).
ACOUSTICAL TILE T-BAR CEILING
EXTEND WALL 0'-6" (MAXIMUM) PAST CEILING - OR AS DICTATED BY
EXITING STRUCTURAL CONDITIONS, SUPPLY DUCT, ETC.
3" BATTS INSULATION BETWEEN STUDS FOR SOUND ATTENUATION.
CONTINUOUS SEALANT AT CEILING INTERFACE OF 5/8" GYP.
MTL. RUNNER - DO NOT FASTEN TO STUD.
HEAD
PLAN
BASE
OVERALL DIMENSION = 4-1/4"
'C' SHAPED MTL. STUD. DO NOT FASTEN TO RUNNER ABOVE.
FASTENERS @ 2'-0" O.C. MAX WITHIN 1" OF ENDS.
TOP OF STRUCTURAL SLAB.
CONTINUOUS SEALANT.
CONTINUOUS C'SHAPED METAL RUNNER.
BASEBOARD.
CLASSROOMCHASE
METAL STUD SIZE - 3-5/8"
WHHP
PROVIDE STEEL CORNER BEAD AT 90
DEG GYP. BOARD OUTSIDE CORNERS.
PROVIDE FRAMED OPENING FOR
SUPPLY DUCT AND RETURN GRILLE
AND DUCT. SEE MECHANICAL
DRAWINGS FOR EXACT SIZE.
SEE MECHANICAL DRAWINGS FOR
SUPPLY & RETURN DUCT SIZES.
EXTERIOR WALL
24" MAXIMUM
48" MAXIMUM
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
GA DOE ID #: 2058
A300
ARCHITECTURAL CHASE
PLAN & DETAILS
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/16" = 1'-0"1 ARCHITECTURAL CHASE PLAN
NOT TO SCALE
CHASE WALL DETAIL
1 . CONSTRUCT CHASE WALL FOR WALL HUNG UNIT DUCTWORK ACCORDING TO
CHASE WALL DETAIL, THIS SHEET.
2 . CONSTRUCT BULKHEAD/SOFFIT TO CONCEAL DUCTWORK RISE. SEE MECHANICAL
PLAN FOR DUCTWORK AND DETAILS.
3 . COORDINATE WITH OWNER FOR THE REMOVAL AND RELOCATION OF SHELVING
FOR NEW MECHANICAL EQUIPMENT IN THIS ROOM.
NOTES: (THIS SHEET ONLY)
NOT TO SCALE
WHHP CHASE WALL DETAIL
MD101
MD101
MD102
MD103
MD103
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
MD100
MECHANICAL DUCT DEMO
OVERALL PLAN
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/16" = 1'-0"1 MECHANICAL OVERALL DEMO PLAN - OVERALL
1 1 1 1 1 1
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
STOR.
CORR.
COMPUTER LAB
COMPUTER LAB
BOYS
GIRLS
1 1 1 1 1
11111
CLASSROOM
COMPUTER LAB
CLASSROOM
COMPUTER LAB
CLASSROOM
BOYS
GIRLS
CORRIDOR
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
MD101
MECHANICAL DEMO PLAN -
SECTOR A & C
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/8" = 1'-0"1 MECHANICAL DEMO PLAN - SECTOR A
1/8" = 1'-0"2 MECHANICAL DEMO PLAN - SECTOR C
1 . REMOVE EXISTING WALL HUNG HEAT PUMP AND ASSOCIATED DISCONNECT. SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW WALL HUNG HEAT PUMP SAME LOCATION.
2 . REMOVE EXISTING CEILING HEATER FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR CEILING HEATER REPLACEMENT.
3 . REMOVE EXISTING PACKAGED ROOF TOP UNIT FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR RTU REPLACEMENT. SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW UNIT.
4 . REMOVE EXISTING ROOF EXHAUST FAN FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN REPLACEMENT.
NOTES: (THIS SHEET ONLY)
No. Description Date
GENERAL NOTE: THIS PROJECT INVOLVES THE REMOVAL AND REPLACEMENT OF
WALL HUNG HEAT PUMPS (WHHP), ROOFTOP HEAT PUMPS (RTU), & FAN COIL
UNITS AND HEAT PUMPS (FCU AND HP). MECHANICAL CONTRACTOR SHALL BE
RESPONSIBLE FOR RECOVERING ALL R-22 REFRIGERANT FROM ALL EXISTING
WHHP, RTU, FCU/HP SYSTEMS REMOVED DURING DEMOLITION PHASE(S).
CONTRACTOR SHALL PROVIDE ALL LABOR AND TOOLS/RECOVERY EQUIPMENT
REQUIRED TO RECOVER R-22 REFRIGERANT. REFRIGERANT RECOVERY
CYLINDERS SHALL BE PROVIDED BY CONTRACTOR. ONCE RECOVERED CYLINDERS
HAVE BEEN FILLED, CYLINDERS SHALL BE RETURNED TO OWNER FOR
PROCESSING.
COMPUTER LAB
CLASSROOM
CORRIDOR
CLASSROOM
CLASSROOM
CAFETERIA
STAGE
DISH WASH
FREEZER
COOLER
VEST.
FOOD STORAGE
CORRIDOR
8 8
91010
11 11
5 5(TYP) (TYP)
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
MD102
MECHANICAL DEMO PLAN -
SECTOR B
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/8" = 1'-0"1 MECHANICAL DEMO PLAN - SECTOR B
NOTES: (THIS SHEET ONLY)
1 . REMOVE EXISTING WALL HUNG HEAT PUMP AND ASSOCIATED DISCONNECT. SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW WALL
HUNG HEAT PUMP SAME LOCATION.
2 . REMOVE EXISTING CEILING HEATER FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR CEILING HEATER REPLACEMENT.
3 . REMOVE EXISTING PACKAGED ROOF TOP UNIT FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR RTU REPLACEMENT. SALVAGE EXISTING GPS
BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW UNIT.
4 . REMOVE EXISTING ROOF EXHAUST FAN FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN REPLACEMENT.
5 . (TYPICAL) EXISTING SUPPLY/RETURN/EXHAUST GRILLE AND ASSOCIATED FLEX DUCT (IF APPLICABLE) IN THIS APPROXIMATE LOCATION TO REMAIN FOR REUSE. SEE
NEW WORK DRAWING FOR AIRFLOW.
6 . REMOVE EXISTING CEILING EXHAUST FAN FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN REPLACEMENT.
7 . REMOVE EXISTING KITCHEN HOOD EXHAUST FAN ON ROOF IN THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN REPLACEMENT.
8 . REMOVE EXISTING AIR HANDLER FROM THIS APPROXIMATE LOCATION. DUCTWORK TO REMAIN FOR REUSE WITH NEW UNIT. REMOVE ALL ASSOCIATED REFRIGEREANT PIPING FROM OUTDOOR UNIT TO INDOOR UNIT. CONDENSATE PIPE TO REMAIN FOR REUSE WITH NEW UNIT. REMOVE EXISTING BIPOLAR UNIT IN
EXISTING UNIT FOR REUSE IN NEW UNIT.
9 . REMOVE EXISTING HEAT PUMP FROM THIS APPROXIMATE LOCATION. CONCRETE EQUIPMENT PAD AND FENCE TO REMAIN FOR REUSE WITH NEW UNIT. REMOVE ALL
ASSOCIATED REFRIGEREANT PIPING FROM OUTDOOR UNIT TO INDOOR UNIT.
10 . EXISTING RETURN DUCT TO REMAIN IN THIS APPROXIMATE LOCATION. OPEN MANUAL VOLUME DAMPER ALL THE WAY TO ALLOW FULL AIRFLOW.
11 . EXISTING LOUVER, DUCTWORK, AND AUTOMATIC VOLUME DAMPER TO REMAIN FOR REUSE. REMOVE ACTUATOR. SEE NEW WORK DRAWINGS FOR INSTALLATION OF
NEW ACTUATOR AND MANUAL VOLUME DAMPER.
12 . EXISTING DISHWASHER EXHAUST FAN TO REMAIN.
13 . EXISTING DUCTWORK IN MECHANICAL ROOM AND ON ROOF TO REMAIN.
14 . EXISTING GRAVITY VENT ON ROOF. CAP AND SEAL VENT AIR TIGHT.
15 . REMOVE ALL EXISITNG DUCTWORK PAST THE SCOPE OF WORK SYMBOL. SEE NEW WORK DRAWINGS FOR NEW DUCTWORK. PROVIDE DUCT END CAP.
16 . REMOVE EXISTING CEILING DIFFUSER IN THIS APPROXIMATE LOCATION.
No. Description Date
GENERAL NOTE: THIS PROJECT INVOLVES THE REMOVAL AND REPLACEMENT OF
WALL HUNG HEAT PUMPS (WHHP), ROOFTOP HEAT PUMPS (RTU), & FAN COIL
UNITS AND HEAT PUMPS (FCU AND HP). MECHANICAL CONTRACTOR SHALL BE
RESPONSIBLE FOR RECOVERING ALL R-22 REFRIGERANT FROM ALL EXISTING
WHHP, RTU, FCU/HP SYSTEMS REMOVED DURING DEMOLITION PHASE(S).
CONTRACTOR SHALL PROVIDE ALL LABOR AND TOOLS/RECOVERY EQUIPMENT
REQUIRED TO RECOVER R-22 REFRIGERANT. REFRIGERANT RECOVERY
CYLINDERS SHALL BE PROVIDED BY CONTRACTOR. ONCE RECOVERED CYLINDERS
HAVE BEEN FILLED, CYLINDERS SHALL BE RETURNED TO OWNER FOR
CLASSROOM
6 6
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
11 (TYP)
11 (TYP)
11 (TYP)
11 (TYP)11 (TYP)11 (TYP)
11 (TYP)
(TYP)12 12 12 12 12 12
121212121212
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
MD103
MECHANICAL DEMO PLAN -
SECTOR D & E
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/8" = 1'-0"1 MECHANICAL DEMO PLAN - SECTOR D
1 . REMOVE EXISTING WALL HUNG HEAT PUMP AND ASSOCIATED DISCONNECT. SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR
INSTALLATION IN NEW WALL HUNG HEAT PUMP SAME LOCATION.
2 . REMOVE EXISTING CEILING HEATER FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR CEILING HEATER REPLACEMENT.
3 . REMOVE EXISTING PACKAGED ROOF TOP UNIT FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR RTU REPLACEMENT.
SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW UNIT.
4 . REMOVE EXISTING ROOF EXHAUST FAN FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN
REPLACEMENT.
5 . REMOVE EXISTING PACKAGED HEAT PUMP UNITS FROM THIS APPROXIMATE LOCATION. DEMO DUCTWORK AND DUCT COVERING UP TO CHASE TO ALLOW FOR NEW DUCTWORK CONNECTION. REMOVE EXISTING BIPOLAR IONIZATION UNIT FOR REUSE IN NEW PACKEGED UNIT.
6 . (TYPICAL) EXISTING DUCTWORK TO REMAIN.
7 . REMOVE EXISTING RETURN GRILLE FROM CEILING IN THIS APPROXIMATE LOCATION.
8 . REMOVE EXISTING ROOF VENTILATOR FROM THIS APPROXIMATE LOCATION. CAP EXISTING CURB.
9 . REMOVE EXISTING AIR HANDLER AND ALL ASSOCIATED PIPING, SUPPORTS, DUCTWORK, ETC. FROM THIS APPROXIMATE LOCATION.
10 . REMOVE ANY AND ALL HVAC RELATED ITEMS FROM MECHANICAL ROOM. THIS INLCUDES BUT IS NOT LIMITED TO, AIR COMPRESSOR, DUCTOWKR, PIPING, BOILER, CONTROLS, ETC.
11 . REMOVE EXISTING DUCTWORK.
12 . REMOVE EXISTING SIDE WALL GRILLE.
13 . REMOVE EXISTING CONDENSING UNIT ON ROOF. DEMO ANY ASSICIATED ELECTRICAL AND PIPING MATERIALS. SEAL ALL ROOF OPENINGS.
NOTES: (THIS SHEET ONLY)
No. Description Date
GENERAL NOTE: THIS PROJECT INVOLVES THE REMOVAL AND REPLACEMENT OF
WALL HUNG HEAT PUMPS (WHHP), ROOFTOP HEAT PUMPS (RTU), & FAN COIL
UNITS AND HEAT PUMPS (FCU AND HP). MECHANICAL CONTRACTOR SHALL BE
RESPONSIBLE FOR RECOVERING ALL R-22 REFRIGERANT FROM ALL EXISTING
WHHP, RTU, FCU/HP SYSTEMS REMOVED DURING DEMOLITION PHASE(S).
CONTRACTOR SHALL PROVIDE ALL LABOR AND TOOLS/RECOVERY EQUIPMENT
REQUIRED TO RECOVER R-22 REFRIGERANT. REFRIGERANT RECOVERY
CYLINDERS SHALL BE PROVIDED BY CONTRACTOR. ONCE RECOVERED CYLINDERS
HAVE BEEN FILLED, CYLINDERS SHALL BE RETURNED TO OWNER FOR
1/8" = 1'-0"2 MECHANICAL DEMO PLAN - SECTOR E
M101
M101
M102
M103
M103
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
M100
MECHANICAL NEW WORK
OVERALL PLAN
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/16" = 1'-0"1 MECHANICAL NEW WORK PLAN OVERALL
WHHP-8 WHHP-9
WHHP-10
WHHP-6WHHP-5WHHP-4WHHP-3WHHP-2WHHP-1
RTU-4
RTU-3
EF-1
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10" B1
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10" B1
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10" B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
1 1 1
1 1 1 1 1 1
CH-1
CC
WHHP-7
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10" B1
MVD
A2
A2
A2
A2
A2
A2
150 A2
A2
COMPUTER LAB
CORR.
10"ø
12"ø 10"ø
12"ø12"x12"
12"ø
CLASSROOM
CLASSROOM
CORRIDOR
300 300
400 400
400400
COMPUTER LAB
CLASSROOM
STOR.
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
JAN.
ENTRY
CLASSROOM
6 6 6 6
6 6 6 6 6 6
TT TT TT TT TT TT
TTTTTTTT
TT
TT
CH-4
DFCU-4.1
DOU-4
DFCU-4.2
3/ 4"
D
/4
D
/2
D
3/4" D
10(TYP)
16"x10"
"x
M101
1 1/4" D
1 1/4" D
R R
A2
A2
8"ø 8"ø 8"ø 8"ø
8"ø8"ø8"ø8"ø
12 (TYP)
L-1
13 13 13 13
131313131313
OAU-1
DFCU-5
DOU-5
R
TT
TT
20"x30"
OAU-CU-1
R
1" D
16"x10"
F.D.
WHHP-16 WHHP-17 WHHP-18 WHHP-19 WHHP-20
WHHP-12WHHP-11
WHHP-13 WHHP-14
WHHP-15
EF-7 EF-8
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
" 10"ø
10"ø10"ø
10"ø A3
A3
A3
A3
30"x10"
B1
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10"
B1
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10" B1
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10" B1
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10" B1
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
A3
A3
30"x10" B1
"x
"x
30"x10"
B1
A3
A3
A3
A3
1 1 1 1
1 1 1 1 1
2 2
CCCC
A2
150A2
A2
A2
A2
A2
150 A2
A2
A2
CH-8
"x
MEDIA PRODUCTION
CORRIDOR
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
CLASSROOM
BOYS
GIRLS
COMPUTER LAB
CLASSROOM
COMPUTER LAB
CLASSROOM
6 6 6 6 6
10 6 6 6
A2
TT TT TT TT TT
TT
TT TT TT TT
DFCU-2.2
DOU-2
DFCU-2.1
8"ø
10"ø12"ø14"x14"
12"ø 10"ø
8"ø
8"ø8"ø8"ø
8"ø 8"ø 8"ø
MVD
MVD
R
1 1/4" D
1 1/4" D
R
(TYP)
13 13 13
131313
8"ø 8"ø
8"ø
INSTALL ACOUSTICAL TILE CEILING BENEATH BULKHEAD/SOFFIT AT NO LOWER THAN 7' 6" A.F.F..
INSTALL 5/8" GYP BOARD ON BULKHEAD FACE (2 SIDES), ANCHORED TO KAM AND PAINTED
TO MATCH EXISTING WALLS.
PROVIDE KNURLED ANGLE MOLDING (KAM) ON BACK WALL FOR GRID MAIN SUPPORT.
FABRICATE SOFFIT FROM BENT DRYWALL ARMSTRONG (OR EQUAL) HD8906 MAIN
RUNNERS. NOTCH AT CORNERS AND SUPPORT WITH DW90 REINFORCEMENT. PROVIDE
LATERAL T-BAR GRID AT 16" ON CENTER.
TERMINATE EXISTING CEILING GRID AT NEW SOFFIT FACE.
PROVIDE BRACING TO WALL AS REQUIRED.
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
M101
MECHANICAL NEW WORK
PLAN - SECTOR A & C
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
NOTES: (THIS SHEET ONLY)
1 . WALL HUNG HEAT PUMP. SEE WALL HUNG HEAT PUMP DETAIL - DUCTED SUPPLY.
2 . ROOF MOUNTED CENTRIFUGAL EXHAUST FAN. SEE ROOF MOUNTED CENTRIFUGAL EXHAUST
FAN DETAIL.
3 . CEILING HEATER.
4 . ROOFTOP AIR CONDITIONING UNIT MOUNTED ON ROOF CURB ADAPTER. SEE ROOF CURB
ADAPTER DETAIL.
5 . DUCT CURB. SEE DUCT CURB DETAIL.
6 . ATTACH NEW DUCT TO EXISTING DUCTWORK AT THIS APPROXIMATE LOCATION. PROVIDE
NECESARY TRANSITIONS/OFFSET AS NEEDED TO MAKE CONNECTION.
7 . NEW DUCTLESS HEAT PUMP MOUNTED ON NEW EQUIPMENT SUPPORT PLATFORM. SEE ROOF
MOUNTED EQUIPMENT SUPPORT PLATFORM DETAIL. REFRIGERANT PIPING ROUTED THROUGH
NEW PIPE BOX ON ROOF. SEE PIPE BOX ASSEMBLY DETAIL.
8 . NEW DUCTLESS CEILING CASSETTE MOUNTED IN CEILING IN THIS APPROXIAMTE LOCATION.
FEILD VERIFY EXISTING CONDITIONS AND SHIFT UNIT AS NEEDED. UNIT'S SUPPLY GRILLE
FACING HOOD SHALL BE BLANKED OFF TO NOT INTERFERE WITH HOOD PERFORMANCE.
9 . PROVIDE FULL SIZE, SLOPED (1/4" PER FOOT), TRAPPED, SCHEDULE 40 PVC PIPING TO
DISCHARGE AS SHOWN ON DRAWINGS . DRAIN PIPING SHALL BE PROVIDED FROM EACH RTAC
AS SHOWN ON DRAWINGS. INSURE THAT DRAIN PIPING DOES NOT BLOCK RTAC ACCESS
PANELS. DO NOT ROUTE DRAIN PIPING IN FRONT OF ACCESS PANELS. SEE CONDENSATE
DRAIN TRAP DETAIL AND CONDENSATE ROOF SUPPORT DETAIL(S).
10 . CONDENSATE PIPE SUPPORT ON ROOF. SEE CONDENSATE PIPE SUPPORT ON ROOF DETAILS.
11 . NEW DUCTLESS CEILING CASSETTE MOUNTED IN CEILING IN THIS APPROXIAMTE LOCATION.
FEILD VERIFY EXISTING CONDITIONS AND SHIFT UNIT AS NEEDED. UNIT'S SUPPLY GRILLE
FACING HOOD SHALL BE BLANKED OFF TO NOT INTERFERE WITH HOOD PERFORMANCE.
12 . CONDENSATE SHALL BE PUMPED FROM UNIT UNIT THROUGH PIPE BOX AND DISCHARGE ONTO
ROOF.
13 . ALL REFRIGERANT PIPING AND CONDENSATE PIPING SHALL BE CONCEALED BEHIND
RECTORSEAL FORTRESS LINE HIDE KIT OR EQUAL ONCE IT PENETRATES CEILING.
14 . NEW DUCTLESS HEAT PUMP MOUNTED ON NEW EQUIPMENT SUPPORT PLATFORM. SEE ROOF
MOUNTED EQUIPMENT SUPPORT PLATFORM DETAIL. REFRIGERANT PIPING ROUTED THROUGH
NEW PIPE BOX ON ROOF. SEE PIPE BOX ASSEMBLY DETAIL.
15 . WALL MOUNTED DUCTLESS FAN COIL UNIT. MOUNT B.E. OF UNIT 6' 8" A.F.F.
16 . CONDENSATE SHALL BE PUMPED FROM UNIT UNIT THROUGH PIPE BOX AND DISCHARGE ONTO
ROOF.
17 . DDC TEMERATURE SENSOR TO MONITOR IDF SPACE TEMPERATURE. MOUNT B.E. 4' 6" A.F.F..
18 . FACTORY WALL MOUNTED DUCTLESS UNIT THERMOSTAT. MOUNT B.E. 4' 6" A.F.F..
19 . 100% OUTSIDE AIR HANDLING UNIT MOUNTED ATOP 4" INTERIOR CONCRETE PAD. SEE
CONCRETE EQUIPMENT PAD DETAIL. SEE INDOOR OA AIR HANDLER DETAIL.
20 . INSTALL LOUVER WITH BOTTOM ELEVATION AT 5'-0" A.F.F. UNLESS NOTED OTHERWISE. SEE
STATIONARY LOUVER DETAIL.
21 . OA DUCT TAPS OUT OF THE BOTTOM OF THE MAIN TRUNK DUCT AND PENETRATES THE
CLASSROOM WALL BELOW THE STRUCTURAL BEAM. DUCT ELBOWS UP AFTER BEAM AND IS
ROUTED ABOVE CEILING. SEE ARCHITECTURAL DRAWINGS FOR DUCT CHASE.
22 . EXISTING DATA PANEL.
23 . EXISTING PLUMBING CLEAN OUT.
24 . 100% OUTDOOR AIR CONDENSING UNIT MOUNTED ATOP CONCRETE EQUIPMENT PAD.
REFRIGERANT AND HOT GAS PIPING SHALL ROUTED INTO BUILDING AS SHOWN. SEE PIPE
SLEEVE DETAIL.
25 . DO NOT BLOCK ACCESS PANELS WITH PIPING.
26 . INSTALL 6' TALL CHAINLINK FENCE AROUND EQUIPMENT YARD IN ACCORDANCE TO
SPECIFICATIONS. INSTALL 3'GATE IN FENCE FOR SERVICE ACCESS.
27 . SOFFIT FOR DUCTWORK. SEE SOFFIT DETAIL.
1/8" = 1'-0"1 MECHANICAL NEW WORK PLAN - SECTOR A
1/8" = 1'-0"2 MECHANICAL NEW WORK PLAN - SECTOR C
No. Description Date
GENERAL NOTE: PROVIDE LINTELS AT ALL NEW DUCT PENETRATIONS
THRU EXISTING WALLS. SEE LINTEL DETAIL AT EXISTING WALL.
1/4" = 1'-0"3 SOFFIT DETAIL
WHHP-15
RTU-2
RTU-1
EF-4
EF-5
EF-12
EF-3EF-2
EF-6
"x
"x
10"ø
10"ø10"ø
10"ø
A3
A3
30"x10"
A3
A3
"x
"x
30"x10"
B1
A3
A3
A3
A3
2 2
CH-5
CH-2
CH-3
CCCC
CC
CH-6
A2
545 545 545 545
A2
CH-7
CH-8
800 800
HP-1
HP-2
KEF-1
KSF-1
DFCU-1
DOU-1
CLASSROOM
CONFERENCE
31 BOOK STORAGE
WORK ROOM
MEDIA CENTER
GIRLS
BOYS
JAN.
RECEPTIONIST
WORKROOM
PRINC.
235.58 SF
TOIL.
ASST. PRINC.
STAFF LOUNGE
KITCHEN
FREEZER
COOLER
VEST.
FOOD STORAGE
CORRIDOR
MECHANICAL
MEDIA PRODUCTION
TOIL.
AV STORAGE
STORAGE
CNSLR.
STORAGE
TOIL.
ELEC
CORRIDOR
CORRIDOR
CAFETERIA
STAGE
STOR.
STOR.
DISH WASH
CAN WASH
JAN.
LOCKERS
10 OFFICE
CLASSROOM
CORRIDOR
R
DAC-1
TT
TT
TT
TT
TT
TT TT
AHU-2
AHU-1
7 7
7 7
1 1/4" D
R R
A1
RTU-2
CH-4
DFCU-2.1
DFCU-3
DOU-3
S
WAITING
MM
MM
R
8"ø
MVD
3/4" D
MM
A1
A1
6"ø 6"ø
8"ø
MVD
6"ø
F.D.
F.D.F.D.
F.D.
TT
TT
NOTES: (THIS SHEET ONLY)
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
M102
MECHANICAL NEW WORK
PLAN - SECTOR B
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/8" = 1'-0"1 MECHANICAL NEW WORK PLAN - SECTOR B
No. Description Date
1 . WALL HUNG HEAT PUMP. SEE WALL HUNG HEAT PUMP DETAIL - DUCTED SUPPLY.
2 . ROOF MOUNTED CENTRIFUGAL EXHAUST FAN. SEE ROOF MOUNTED CENTRIFUGAL EXHAUST FAN DETAIL.
3 . CEILING HEATER.
4 . ROOFTOP AIR CONDITIONING UNIT MOUNTED ON ROOF CURB ADAPTER. SEE ROOF CURB ADAPTER DETAIL.
5 . 100% OUTSIDE AIR UNIT MOUNTED ON ROOF. UNIT WILL DISCHARGE HORIZONTALLY.
7 . ATTACH NEW DUCT TO EXISTING DUCTWORK AT THIS APPROXIMATE LOCATION. PROVIDE NECESARY
TRANSITIONS/OFFSET AS NEEDED TO MAKE CONNECTION.
8 . EXISTING GOOSE NECK FOR COMBUSTION AIR.
9 . NEW DOOR AIR CURTAIN MOUNTED IN SAME LOCATION AS DOOR AIR CURTAIN REMOVED DURING DEMOLITION. FIELD VERIFY EXISTING DOOR DIMENSIONS TO ENSURE NEW DOOR AIR CURTAIN MATCHES.
10 . NEW HEAT PUMP MOUNTED ON EXSITING CONCRETE EQUIPMENT PAD. ROUTE NEW REFRIGERANT LINES
FROM NEW HEAT PUMP TO NEW FAN COIL UNIT USING THE EXISTING WALL PENETRATIONS.
11 . NEW VERTICAL FAN COIL UNIT MOUNTED IN PLACE OF EXISTING. CONNECT TO EXISTING SUPPLY DUCT AND CONDENSATE LINE. ROUTE NEW REFRIGERANT LINES ALONG THE EXISTING REFRIGERANT LINE'S PATH.
12 . NEW KITCHEN HOOD SUPPLY FAN MOUNTED ON EXISTING CURB. PROVIDE CURB ADAPTER AS NEED.
13 . NEW KITCHEN HOOD EXHAUST FAN MOUNTED ON EXISTING CURB. PROVIDE CURB ADAPTER AS NEED.
14 . NEW DUCTLESS HEAT PUMP MOUNTED ON NEW EQUIPMENT SUPPORT PLATFORM. SEE ROOF MOUNTED EQUIPMENT SUPPORT PLATFORM DETAIL. REFRIGERANT PIPING ROUTED THROUGH NEW PIPE BOX ON
ROOF. SEE PIPE BOX ASSEMBLY DETAIL.
15 . NEW DUCTLESS CEILING CASSETTE MOUNTED IN CEILING IN THIS APPROXIAMTE LOCATION. FEILD VERIFY EXISTING CONDITIONS AND SHIFT UNIT AS NEEDED. UNIT'S SUPPLY GRILLE FACING HOOD SHALL BE
BLANKED OFF TO NOT INTERFERE WITH HOOD PERFORMANCE.
16 . CAP AND SEAL EXISTING GRAVITY VENT ON ROOF AIR TIGHT.
17 . NEW DDC CONTROL PANEL MOUNTED ON WALL. V
18 . EXISTING DUCT MOUNTED SMOKE DETECTOR.
19 . ALL REFRIGERANT PIPING AND CONDENSATE PIPING SHALL BE CONCEALED BEHIND RECTORSEAL
FORTRESS LINE HIDE KIT OR EQUAL ONCE IT PENETRATES CEILING.
20 . CONDENSATE SHALL BE PUMPED FROM UNIT UNIT THROUGH PIPE BOX AND DISCHARGE ONTO ROOF.
21 . WALL MOUNTED DUCTLESS FAN COIL UNIT. MOUNT B.E. OF UNIT 6' 8" A.F.F.
22 . DDC TEMERATURE SENSOR TO MONITOR IDF SPACE TEMPERATURE. MOUNT B.E. 4' 6" A.F.F..
23 . FACTORY WALL MOUNTED DUCTLESS UNIT THERMOSTAT. MOUNT B.E. 4' 6" A.F.F..
GENERAL NOTE: PROVIDE LINTELS AT ALL NEW DUCT PENETRATIONS
WHHP-11
RTU-6
RTU-5
"x
"x
" 10"ø
10"ø10"ø
10"ø
A3
A3
30"x10"
B1
CC CC
EF-9EF-10
CH-9
CH-10
400400
400 400 300
875 875
875 875
875 875
875 875
OAU-2
"x
ART CENTER
STOR.
STOR.
MUSIC ROOM
CLASSROOM
CORRIDOR
GIRLS
TOIL.
46JAN.
STOR.
GYMNASIUM
COACHES OFFICE
TOIL.
BOYS
RTU-7 RTU-8
A2
TT
TT
TT
16 16
150 -
A1
6"ø
3/4" D
3/4" D
/2
D
18(TYP)
18(TYP)
22 22
TTTT
S
EF-11
CC
D1
D1
D1
D1
D1
D1
"x
8"ø 12"x6"
12"x6"
8"ø 8"ø 8"ø
12"x6"
12"x6"
8"ø
8"ø 12"x6"12"x6"8"ø
12"ø
IU-5
IU-2
IU-3
IU-1
IU-6 IU-7 IU-8
IU-4
MBC-1
HRU-1
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
CLASSROOM
CLASSROOM
GIRLS
BOYS
JAN.
OAU-3
TT
TT
TT TT
TT TT
R R
R
R
RRR
R
R
R
TT
23 23
232323
1 1/2" D
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
M103
MECHANICAL NEW WORK
PLAN - SECTOR D & E
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/8" = 1'-0"1 MECHANICAL NEW WORK PLAN - SECTOR D
1/8" = 1'-0"2 MECHANICAL NEW WORK PLAN - SECTOR E
1 . WALL HUNG HEAT PUMP. SEE WALL HUNG HEAT PUMP DETAIL - DUCTED SUPPLY.
2 . ROOF MOUNTED CENTRIFUGAL EXHAUST FAN. SEE ROOF MOUNTED CENTRIFUGAL EXHAUST FAN
DETAIL.
3 . CEILING HEATER.
4 . ROOFTOP AIR CONDITIONING UNIT MOUNTED ON ROOF CURB ADAPTER. SEE ROOF CURB ADAPTER
DETAIL.
5 . VRF CEILING CASSETTE. SUSPENDED FROM DROP RODS (MIN 3/8") CONNECTED TO OVERHEAD
STRUCTURE WITH SUPPLEMENTAL 2"X2"X1/4" ANGLE IRON.
6 . MAIN/SUB VRF BRANCH CONTROLLER. BRANCH CONTROLLER SHALL BE MOUNTED ABOVE CEILING.
SUSPEND FROM DROP RODS (MIN 3/8") AND CONNECTED TO OVERHEAD STRUCTURE WITH 2"X2"X1/4" ANGLE IRON. PROVIDE DRAIN PAN BELOW MBC/SBC.SEE VRF DRAIN PAN DETAIL. PROVIDE AUXILIARY
DRAIN PAN UNDER BRANCH CONTROLLER. SEE CONDENSATE AUXILIARY DRAIN PAN DETAIL.
MOUNT RECTORSEAL AG9150 SENSOR IN PAN AND AUDIBLE ALARM. ALARM SHALL BE MOUNTED AT
CEILING LEVEL. PROVIDE 24V TRANSFORMER TO POWER SENSOR.
7 . VRF HEAT RECOVERY UNIT MOUNTED ON CONCRETE EQUIPMENT PAD.
8 . 100% OUTSIDE AIR DUCT PENETRATES BUILDING IN THIS APPROXIMATE LOCATION. SEE
RECTANGULAR DUCT THRU EXTERIOR WALL DETAIL.
9 . 100% OUTSIDE AIR UNIT MOUNTED ATOP CONCRETE EQUIPMENT PAD. SEE CONCRETE EQUIPMENT
PAD DETAIL.
10 . ATTACH NEW DUCT TO EXISTING DUCTWORK AT THIS APPROXIMATE LOCATION.
11 . GENERAL: PIPE SLEEVES. SEE PIPE SLEEVE DETAIL.
12 . REFRIGERANT BRANCH LIQUID AND GAS REFRIGERANT PIPING TO INDOOR UNIT FROM BRANCH
CONTROLLER. SEE VRF SCHEMATIC FOR REFRIGERANT PIPE SIZES.
13 . REFRIGERANT HIGH PRESSURE AND LOW PRESSURE REFRIGERANT PIPING FROM OUTDOOR UNIT
TO MAIN BRANCH CONTROLLER. SEE VRF SCHEMATIC FOR REFRIGERANT PIPE SIZES. MOUNT
EXTERIOR REFRIGERANT PIPE ON ROOF ATOP B-LINE DURABLOCK (DB) SUPPORTS. SUPPORT
PIPING ON 6 FT. CENTERS.
14 . MAIN 1.5" CONDENSATE DRAIN PIPING SHALL BE LOCATED AS HIGH AS POSSIBLE. CONDENSATE
SHALL HAVE PROPER SLOPE (MIN 1/4" PER FOOT).
15 . PROVIDE 1.5" ELBOW UP AND MINIMUM 8" TALL VERTICAL OPEN STAND PIPE AT THIS APPROXIMATE
LOCATION.
16 . GROUND MOUNTED HORIZONTAL DISCHARGE PACKAGED HEAT PUMP MOUNTED ON EXISTING
CONCRETE EQUIPMENT PAD. VERIFY EXISTING PAD WILL SUFFICE. EXTEND AS NEEDED. SEE
CONCRETE EQUIPMENT PAD DETAIL.
17 . VRF CENTRALIZED CONTROLLER MOUNTED ON WALL WITH B.E. 4' 6" A.F.F.
18 . CONDENSATE PIPE SUPPORT ON ROOF. SEE CONDENSATE PIPE SUPPORT ON ROOF DETAILS.
19 . PROVIDE FULL SIZE, SLOPED (1/4" PER FOOT), TRAPPED, SCHEDULE 40 PVC PIPING TO DISCHARGE
AS SHOWN ON DRAWINGS . DRAIN PIPING SHALL BE PROVIDED FROM EACH RTAC AS SHOWN ON
DRAWINGS. INSURE THAT DRAIN PIPING DOES NOT BLOCK RTAC ACCESS PANELS. DO NOT ROUTE
DRAIN PIPING IN FRONT OF ACCESS PANELS. SEE CONDENSATE DRAIN TRAP DETAIL AND
CONDENSATE ROOF SUPPORT DETAIL(S).
20 . EXTEND CONCRETE EQUIPMENT PAD AND FENCING (ACCORDING TO SPEC) AS NEEDED TO FIT NEW UNIT. EXISITING FENCE MAY NEED EXTENSION AS WELL. FIELD VERIFY EXACT EXTENSIONS NEEDED.
SEE CONCRETE EQUIPMENT PAD DETAIL.
21 . WALL MOUNTED DDC SPACE TEMPERATURE/HUMIDITY SENSOR. MOUNT B.E. OF SENSOR 4' 6" A.F.F..
22 . WALL MOUNTED DDC SPACE TEMPERATURE/HUMIDITY SENSOR. MOUNT B.E. OF SENSOR 4' 6" A.F.F..
23 . FACTORY WALL MOUNTED VRF WIRED UNIT THERMOSTAT/CONTROLLER. MOUNT B.E. 4' 6" A.F.F..
24 . INSTALL 6' TALL CHAINLINK FENCE AROUND EQUIPMENT YARD IN ACCORDANCE TO SPECIFICATIONS.
INSTALL 3'GATE IN FENCE FOR SERVICE ACCESS.
NOTES: (THIS SHEET ONLY)
GENERAL: DRAWINGS SHOW GENERAL ARRANGEMENT, LAYOUT AND LOCATION OF PIPING, APPURTENANCES, ETC., BUT DO NOT SHOW ALL REQUIRED FITTINGS AND OFFSETS THAT MAY BE NECESSARY TO RUN PIPING AND CONNECT TO EQUIPMENT, ETC. OFFSET PIPING AROUND ALL OBSTRUCTIONS. FABRICATE AND INSTALL PIPING, FITTINGS, ETC. BASED ON FIELD MEASUREMENTS. PROVIDE ALL NECESSARY FITTINGS AND OFFSETS AT NO ADDITIONAL COST TO THE OWNER. PIPE ROUTING SHOWN ON DRAWINGS SHALL BE ALTERED BY CONTRACTOR WHERE REQUIRED TO AVOID INTERFERENCE AND CLEARANCE DIFFICULTIES. CAREFULLY COORDINATE PIPE ROUTING WITH ROOF MOUNTED GAS PIPING, CONDUITS AND EQUIPMENT TO AVOID
CONFLICTS .
No. Description Date
GENERAL NOTE: PROVIDE LINTELS AT ALL NEW DUCT PENETRATIONS
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
GA DOE ID #: 2058
M301
PIPING/WIRING DIAGRAMS
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
NOT TO SCALE
VRF PIPING DIAGRAM
NOT TO SCALE
VRF WIRING DIAGRAM
GENERAL NOTES:
1. EQUIPMENT MODEL NUMBERS INDICATED ARE FOR BASIS-OF-DESIGN
MANUFACTURER, CARRIER, UNLESS NOTED OTHERWISE.
2. REFRIGERANT PIPING SIZES INDICATED ARE APPROXIMATE AND SHALL BE
VERIFIED / COORDINATED WITH EQUIPMENT SUPPLIER BASED ON REQUIRED
LENGTHS, SYSTEM LAYOUT / INSTALLATION, SYSTEM CAPACITY, AND OTHER
FACTORS AS REQUIRED BY MANUFACTURER.
NOT TO SCALE
VRF CENTRALIZED CONTROLLER
No. Description Date
NOT TO SCALE
OAU-1 HOT GAS BYPASS PIPING DIAGRAM
NOT TO SCALE
OAU-1 HOT GAS REHEAT PIPING DIAGRAM
MAIN ROUND TRUNK DUCT
2 3/16" DUCT WRAP INSULATION FOR
SUPPLY AND RETURN DUCT
OPENING IN SIDE OF RECTANGULAR SHEET METAL
DUCT SHALL BE CUT WITH DRILL-CUTTER OR TIN
SNIPS. DIAMETER OF OPENING SHALL MATCH INNER
DIAMETER OF FOAM GASKET OR DIAMETER
RECOMMENDED BY TAKEOFF MANUFACTURER
DUCT
DUCT MASTICSHEET METAL SCREWS ON 6" CENTERS
FOAM GASKET
EXTERIOR VAPOR BARRIER (ONLY) SECURED
TO FITTING WITH NYLON "ZIP STRIP" BAND
SECURE INNER DUCT TO FITTING WITH NYLON
ZIP STRIP BAND IN ADDITION TO NYLON
STRIPBAND. SEAL INNER CORE TO DUCT.
FLEXIBLE DUCTWORK
90° SADDLE TAKEOFF COLLAR DAMPER AND THERMA-SEAL
GASKET FLANGE AND DAMPER HANDLE STANDOFF, SIMILAR TO
CROWN PRODUCT MODEL #314-DSO
FOR SUPPLY/RETURN DUCTS, INSULATE ENTIRE FITTING (EXCEPT OPERATOR
HANDLE) WITH 2 3/16" DUCT WRAP. SEAL WITH VAPOR PROOF MASTIC AND CLOTH
FABRIC OVERLAPPING ESCUTCHEON AND DUCT WRAP FSK JACKET TO PREVENT
PASSAGE OF SMOKE.
20 GAUGE GALVANIZED SHEET METAL COVER
SEAL AND CAULK ALL JOINTS WATERTIGHT
A S
R E
Q U
IR
E
D
AS REQUIRED
SHEET METAL COVER ATOP ANGLE IRON
CONTINUOUS INSULATION
LAG SCREWS TO CURB ON MAXIMUM 16" CENTERS
EXISTING ROOF CURB TO REMAIN FOR REUSE
EXISTING ROOF AND DECK
PLAN VIEW
ELEVATION VIEW
CONTRACTOR SHALL FIELD VERIFY
EXACT CURB DIMENSIONS PRIOR
TO FABRICATING CURB CAP.
3" X 3" X ¼" ANGLE IRON FULLY WELDED
(PROVIDE CENTER ANGLE AT MIDSPAN
FOR ALL CURBS LARGER THAN 8 SQ. FT.)
NOTE: ALL ITEMS IN THIS DETAIL ARE NEW UNLESS NOTED OTHERWISE.
CURB CAP IS TO BE CONSTRUCTED OF 3" X 3" X ¼" ANGLE IRON
MEMBERS, MITERED OR BUTTED AS SHOWN AND WELDED TOGETHER.
COVER ENTIRE FRAME WITH 20 GA. GALVANIZED SHEET METAL. SEAL
AND CAULK ALL SEAMS WATERTIGHT. LINE ENTIRE UNDERSIDE WITH 1 ½"
RIGID FIBERGLASS INSULATION. SECURE TO EXISTING CURB WITH
GALVANIZED LAG SCREWS ON 16" CENTERS.
PROVIDE 1" WIDE CLOSED CELL
ELASTOMERIC (ARMAFLEX) TAPE
AROUND FULL PERIMETER OF
CURB TO SEAL COVER TO CURB.
PROVIDE BACKERBOARD IN ANY GAPS
AND SEAL AIR TIGHT WITH SILICONE
CAULK AROUND FULL PERIMETER
AT POINT WHERE ANGLE IRON OVERLAPS
CURB.
CEILING, BY ARCHITECTURAL
SQUARE TO ROUND TRANSITION (WHERE ELBOW CONNECTS TO SQUARE
NECK DIFFUSERS). PROVIDE ROUND TO ROUND TRANSITION WHERE GRILLE
NECK SIZE DIFFERS FROM CONNECTING DUCT SIZE (EITHER LARGER OR
SMALLER). INSULATE ON SUPPLY DUCTS.
3 GORE ADJUSTABLE ELBOW. INSULATE
ON SUPPLY DUCTS.
NYLON ZIP STRIP ON OUTER VAPOR BARRIER.
ENSURE INSULATION IS PULLED DOWN WITH
VAPOR BARRIER SO NO DUCTWORK IS
UNINSULATED.
NOTE: DETAIL IS TYPICAL FOR ALL FLEX DUCT RUNOUTS TO DIFFUSERS
STAINLESS STEEL DRAWBAND
ON INNER DUCT
FLEX DUCT
INSULATION BLANKET ON TOP
OF SUPPLY DIFFUSERS
CEILING DIFFUSER
J
POWER WIRING AND CONDUIT BY ELECTRICAL
PROVIDE "KNOCK OUT" AND GROMMET
FOR POWER CABLE
ROOF CURB. SEE ROOF CURB DETAIL.
POWER CABLE BY ELECTRICAL
REMOVABLE ACCESS COVER FOR MOTOR
COMPARTMENT
INTERNAL FACTORY INSTALLED NEMA-1 DISCONNECT
SWITCH UNLESS SCHEDULED OTHERWISE
SEE SCHEDULE FOR DRIVE TYPE. (PROVIDE
ADJUSTABLE SHEAVE FOR ALL BELT DRIVE)
FACTORY WIRED FROM MOTOR TO
DISCONNECT SWITCH.
EXHAUST FAN
FACTORY FURNISHED DAMPER TRAY TO SUPPORT
BACK DRAFT DAMPER AND PROVIDE DUCT
ATTACHMENT.
FULL PERIMETER ANGLE IRON FRAMING BENEATH
CURB BY STRUCTURAL.
SECURE DUCT TO ROOF STRUCTURE WITH SHEET
METAL ON 4 SIDES. DUCT SHALL NOT BE
SUPPORTED BY DAMPER TRAY.
EXHAUST DUCT UP FROM BELOW
EXHAUST DUCT SHALL TRANSITION AS REQUIRED AT
UNDERSIDE OF ROOF DECK TO MATCH FANS DAMPER/
CURB SIZE.
MINIMUM 1 1/4" CLEARANCE FOR CONDUIT
FACTORY INSTALLED, MINIMUM 1/2"
DIA. CONDUIT CHASE
J
POWER WIRING AND CONDUIT BY ELECTRICAL
PROVIDE "KNOCK OUT" AND GROMMET
FOR POWER CABLE
ROOF CURB. SEE ROOF CURB DETAIL.
POWER CABLE BY ELECTRICAL
REMOVABLE ACCESS COVER FOR MOTOR
COMPARTMENT
INTERNAL FACTORY INSTALLED NEMA-1 DISCONNECT
SWITCH UNLESS SCHEDULED OTHERWISE
SEE SCHEDULE FOR DRIVE TYPE.
FACTORY WIRED FROM MOTOR TO
DISCONNECT SWITCH.
UPBLAST EXHAUST FAN
FACTORY FURNISHED DAMPER TRAY TO SUPPORT
BACK DRAFT DAMPER AND PROVIDE DUCT
ATTACHMENT.
FULL PERIMETER ANGLE IRON FRAMING BENEATH
CURB BY STRUCTURAL.
SECURE DUCT TO ROOF STRUCTURE WITH SHEET
METAL ON 4 SIDES. DUCT SHALL NOT BE
SUPPORTED BY DAMPER TRAY.
EXHAUST DUCT UP FROM BELOW
EXHAUST DUCT SHALL TRANSITION AS REQUIRED AT
UNDERSIDE OF ROOF DECK TO MATCH FANS DAMPER/
CURB SIZE.
MINIMUM 1 1/4" CLEARANCE FOR CONDUIT
FACTORY INSTALLED, MINIMUM 1/2"
DIA. CONDUIT CHASE GALVANIZED BIRD SCREEN
SECURE CURB CAP TO CURB WITH ANCHORS ON
MAXIMUM 12" CENTERS (MINIMUM 2 ANCHORS
EACH SIDE)
GRADE
WELDED WIRE MESH
AT MID DEPTH OF SLAB
6" X 6" 10/10 WWF
3000 PSI CONCRETE
1" CHAMFER
SEE SPECIFICATIONS FOR
PAD HEIGHT ABOVE
ADJACENT GRADE
2" MINIMUM
EXTERIOR CONCRETE PAD
FLOOR
1" CHAMFER
ANCHOR (TYPICAL OF 4)
INTERIOR CONCRETE PAD
WELDED WIRE MESH
AT MID DEPTH OF SLAB
6" X 6" 10/10 WWF
SEE SPECIFICATIONS FOR
PAD HEIGHT ABOVE
ADJACENT GRADE
2"
3000 PSI CONCRETE
1½"
3"
UNION
AC UNIT
DRAIN CONNECTION
DRAIN PIPE SHALL BE AT LEAST
THE SAME DIAMETER AS THE NIPPLE
ON THE DRAIN PAN CONNECTION
OPEN END NIPPLE
SEE DRAWINGS FOR
PIPE REQUIRED MATERIAL
SLOPE AS REQUIRED
IN SPECIFICATIONS
PIPE NIPPLE
6"
FRONT VIEW
4"
SIDE VIEW
V A
R
IE
S
CONDENSATE PIPE,
VERIFY SIZE (TYP)
UV - STABILIZED, EDPM ADJUSTABLE RUBBER PIPE
SUPPORT, VERIFY PIPE DIAMETER BEING SUPPORTED.
SPACED ON MAXIMUM 8 FT. CENTERS AND 24" OF
FITTINGS (ERICO CADDY PYRAMID RPSE - TYPICAL)
INSTALL CONDENSATE PIPE AT THE LOWEST
POSSIBLE ELEVATION TO REDUCE TOP
HEAVY PIPE AND TO REDUCE TIPPING OVER
BUT TO MAINTAIN SPECIFIED SLOPE.
GENERAL: THIS CONDENSATE SUPPORT SHALL BE USED WITH DRAIN ELEVATIONS ABOVE ROOF OF 7" OR LESS. CONDENSATE ELEVATIONS ABOVE 8" SHALL USE ERICO CADDY PYRAMID ST ADJUSTABLE
STRUT SUPPORT OR EQUAL BY MIRO.
OPENING IN SIDE OF RECTANGULAR
SHEET METAL DUCT SHALL BE CUT
WITH DRILL CUTTER (NOT TIN SNIPS).
DIAMETER OF OPENING SHALL MATCH
INNER DIAMTER OF FOAM GASKET.
DUCT
DUCT MASTIC
FOAM GASKET
SHEET METAL SCREWS
ON 4" CENTERSDUCT
2" DUCT WRAP INSULATION FOR SUPPLY DUCT
EXTERIOR VAPOR BARRIER (ONLY) SECURED TO
FITTING WITH NYLON "ZIP-STRIP" BAND
FLEXIBLE DUCTWORK
BELLMOUTH OR 45° FITTING WITH DAMPER
FOR SUPPLY DUCTS, INSULATE ENTIRE FITTING (EXCEPT OPERATOR HANDLE)
WITH 2" DUCTWRAP. SEAL WITH VAPOR PROOF MASTIC AND CLOTH FABRIC OVERLAPPING
ESCUTCHEON AND DUCT WRAP FSK JACKET TO PREVENT PASSAGE OF SMOKE.
PROVIDE OPTIONAL EXTENDED NECK SHAFT
FOR INSULATED DUCTS TO CLEAR INSULATION THICKNESS
SECURE INNER DUCT TO FITTING WITH 1/2" STAINLESS STEEL
DRAW BAND. CONTRACTOR SHALL NOT UTILIZE NYLON "ZIP-
STRIP" BAND TO SECURE INNER DUCT TO FITTING.
AIR
NOTE: SINGLE BI-POLAR IONIZATION UNIT SHOWN. INSTALLATION SIMILAR WHEN
MULTIPLE UNITS ARE INSTALLED IN ONE HVAC UNIT, EXCEPT 24V WIRING FROM
HVAC UNIT'S TERMINAL SIDE SHALL FEED CONTRACTOR FURNISHED TERMINAL
STRIP, WHICH SHALL THEN FEED POWER TO MULTIPLE UNITS. CONTRACTOR
FURNISHED TERMINAL STRIP SHALL BE ELECTRICALLY ISOLATED FROM THE HVAC
UNIT CASING AND ALL OTHER METAL COMPONENTS.
SECURE WITH SCREWS IN LOCATION THAT
WILL NOT DAMAGE HVAC EQUIPMENT OR
ASSOCIATED REFRIGERANT PIPE, WIRING
OR OTHER COMPONENTS
NEEDLEPOINT ELECTRODES. ENSURE UNIT IS
ORIENTED AND INSTALLED SO THAT AIR FLOW
PASSES BETWEEN ELECTRODES (INSTALL
PERPENDICULAR TO AIRFLOW). MAINTAIN
MANUFACTURER'S DISTANCE FROM NEEDLES
TO METAL SURFACE TO PREVENT ARCING.
FACTORY
FURNISHED
24VAC WIRING
BI-POLAR UNIT. SEE SCHEDULE FOR QUANTITY.
SEE ENLARGED DRAWING BELOW.
LED CONFIRMING IONIZATION OPERATION
B.A.S. CONTACTS TO ALLOW OWNER TO MONITOR STATUS.
MONITORING IS NOT INCLUDED IN THIS PROJECT.
BI-POLAR IONIZATION UNIT MOUNTED INSIDE UNIT DOWNSTREAM OF
FILTER IN SUPPLY AIRSTREAM IN LOCATION APPROVED BY HVAC
EQUIPMENT MANUFACTURER AND BI-POLAR MANUFACTURER
(FAN)
(24V POWER)
G
R
Y
W
C
O
CONNECT TO FAN AND 24V POWER TERMINALS ON 24 VAC
TERMINAL STRIP IN HVAC EQUIPMENT. ADDITIONAL GENERIC
TERMINALS ARE SHOWN FOR SYMBOLIC PURPOSES AND
ACTUAL TERMINALS WILL VARY BASED ON TYPE OF
EQUIPMENT.
PROVIDE ADDITIONAL WIRING (AS REQUIRED) IF FACTORY FURNISHED
WIRING WILL NOT REACH 24VAC TERMINAL STRIP. PROVIDE WIRE NUTS
AND ELECTRICAL TAPE AT JOINT. MATCH WIRE GAUGE OF
MANUFACTURER'S WIRING.
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
GA DOE ID #: 2058
M501
MECHANICAL DETAILS
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
NOT TO SCALE
90° SADDLE TAP TAKEOFF FITTING DETAIL
NOT TO SCALE
CAP AT EXISTING CURB
NOT TO SCALE
CEILING GRILLE DUCT CONNECTION DETAIL
NOT TO SCALE
CENTRIFUGAL DOWN BLAST EXHAUST FAN DETAIL
NOT TO SCALE
CENTRIFUGAL UPBLAST EXHAUST FAN DETAIL (CHECK)
NOT TO SCALE
CONCRETE EQUIPMENT PAD DETAIL
NOT TO SCALE
CONDENSATE DRAIN TRAP DETAIL
NOT TO SCALE
CONDENSATE PIPE SUPPORT ON ROOF DETAIL
NOT TO SCALE
BELLMOUTH AND 45° TAKEOFF FITTING DETAIL
NOT TO SCALE
COMPACT BI-POLAR IONIZATION UNIT DETAIL
PROVIDE INSULATED HOUSING WHERE SCHEDULED
DUCT
AIRFLOW
PARALLEL BLADE BACKDRAFT DAMPER
SQUARE ACCESS PANEL FOR DAMPER ACTUATOR ACCESS
ACCESS PANEL (BOTH SIDES)
MOUNTING BRACKETS (TYP)
HANGING VIBRATION ISOLATORS. SEE SPECS FOR TYPE.
THREADED ROD
SUPPLEMENTAL ANGLE IRON FRAMING
DOUBLE NUTS
DOUBLE NUTS
DUCT
MOTOR. SEE SPECS FOR TYPE.
NOTE: BELT DRIVE FAN SIMILAR, EXCEPT MOTOR
OUTISDE OF FAN CASING, AND WITH INSULATED
MOTOR COVER WHERE SPECIFIED.
DUCT MOUNTING COLLAR (TYP INLET AND OUTLET). PROVIDE
1/2" X 1/2" WELDED WIRE GALVANIZED INLET GUARD FOR
NON-DUCTED INLET APPLICATIONS AS SCHEDULED.
MAINTAIN MINIMUM 2.5 TIMES WHERE DIAMETER STRAIGHT
DUCT LENGTH AT INLET AND OUTLET OF FAN BEFORE
ELBOW, TRANSITION, DAMPER, ETC.
PROVIDE MOTORIZED DAMPER WITH INTERNAL ACTUATOR WHERE
SCHEDULED. DAMPER VOLTAGE SHALL MATCH FAN VOLTAGE.
FLEXIBLE DUCT
CONNECTION (TYP)
GALVANIZED MOTOR COVER
WHERE SCHEDULED
BACKWARD
INCLINED WHEEL
MAINTAIN MINIMUM 2.5 TIMES
WHEEL DIAMETER STRAIGHT
DUCT LENGTH AT INLET AND
OUTLET OF FAN BEFORE ELBOW,
TRANSITION, DAMPER, ETC.
FACTORY INSTALLED NEMA-1
DISCONNECT SWITCH
FACTORY WIRED FROM MOTOR
TO DISCONNECT SWITCH
WELD SIDE ANGLE CLIP TO PAN (TYP OF 4)
TO CORNERS. SUSPEND WITH 3/8"
THREADED ROD. DO NOT BLOCK ACCESS
TO CONTROLLER.
PAN SHALL BE MIN. 18 GAUGE
GALVANIZED STEEL
2"
3/4" NIPPLE WELDED
TO PAN
PIPE 3/4" PAN DRAIN TO LOCATION
SHOWN ON DRAWINGS. SLOPE
PAN TO THIS SIDE.
FABRICATE DRAIN PAN MINIMUM
12" LONGER AND WIDER THAN
MAIN/SUB CONTROLLER
FABRICATE DRAIN PAN MINIMUM
12" LONGER AND WIDER THAN
MAIN/SUB CONTROLLER
18 GAUGE GALVANIZED SHEET METAL COVER FACTORY
FABRICATED BY EQUIPMENT SUPPORT MANUFACTURER
SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.AS REQUIRED
RAISED CHANNEL SUPPORT FOR
MOUNTING OF HEAT PUMPS (TYP).
CHANNELS TO BE FACTORY
FABRICATED INTO COVER.
COORDINATE SPACING OF SUPPORT CHANNELS
WITH DIMENSIONS OF HEAT PUMPS BEING
INSTALLED ATOP PLATFORM. SEE PLANS
FOR UNIT LAYOUT.
ROOF CURB. SEE ROOF CURB DETAIL.COORDINATE LENGTH OF PLATFORM
REQUIRED WITH UNIT LAYOUT INDICATED
ON PLANS
ISOMETRIC VIEW
HEAT PUMP UNIT. SEE PLANS FOR SIZING AND LAYOUT.
SECURE HEAT PUMP
TO SUPPORT CHANNEL.
LAG SCREWS TO CURB ON
MAXIMUM 16" CENTERS.
ROOF CURB. SEE
ROOF CURB DETAIL.
PROVIDE FACTORY FURNISHED
INTERNAL SUPPORT CHANNELS
AS REQUIRED TO SUPPORT
WEIGHT OF HEAT PUMP UNITS.
ROOF DECK SHALL BE
CONTINUOUS UNDER CURB.
6" (MIN.)
FRONT VIEW
PRESSURE TREATED WOOD NAILER
SHEET METAL SCREW IN SIDE OF
COUNTER FLASHING (TYP)
18 GAUGE GALVANIZED STEEL
COUNTER FLASHING
SHEET METAL SCREW (TYP)
18 GAUGE STEEL BASE SECTION
FIELD INSTALLED INSULATION
INTEGRAL 18 GAUGE
GALVANIZED
STEEL BASE PLATE
FIELD INSTALLED CANT
ROOF DECK CONTINUOUS
BENEATH SUPPORT RAIL
SEE ARCHITECTURAL DRAWINGS FOR SPECIFIC
DETAILS CONCERNING ROOF CONSTRUCTION,
FLASHING, ANCHORS, BLOCKING,
ROOF DECK TYPE, ETC.
C U
R B
H E
IG
H
T
S T
Y
LE
A
S T
Y
LE
B
S T
Y
LE
C
2" MAX.
1" 1"
FOLDING BLADE STATIC RATED FIRE DAMPER
IN TYPE 'B' FRAME (EXCEPT TYPE 'A' SHALL BE
USED AT SIDEWALL REGISTERS AND NON-DUCTED
TRANSFER OPENING). DYNAMIC RATED DAMPERS
SHALL BE USED WHERE SPECIFICALLY SHOWN
ON DRAWINGS
ATTACH FIRE DAMPER TO SLEEVE IN
ACCORDANCE WITH MANUFACTUER'S
UL INSTALLATION INSTRUCTIONS
FACTORY FURNISHED ROUND OR OVAL
TRANSITION WITH BLADE STACK OUT
OF AIR STREAM
ROUND AND OVAL FIRE DAMPER
INSTALLATION SIMILAR
DUCT (WHERE APPLICABLE)
SLEEVE LENGTH SHALL BE DETERMINED BY CONTRACTOR TO
BE WITHIN MINIMUM AND MAXIMUM DISTANCE FROM
WALL/FLOOR AS REQUIRED BY MANUFACTUER
NOTE: INSTALLATION SHALL CONFORM TO THE FIRE
DAMPERS MANUFACTURER'S "UL" INSTALLATION
INSTRUCTIONS
WALL OR FLOOR. CONTRACTOR SHALL VERIFY
THICKNESS RATING, AND MATERIAL OF
CONSTRUCTION FROM ARCHITECTURAL DRAWINGS,
AND USE THIS INFORMATION TO SELECT FIRE
DAMPER AND FIRE DAMPER ACCESSORIES.
PROVIDE MINIMUM OVERLAP ALL AROUND AS REQUIRED BY
MANUFACTURER'S UL INSTALLATION INSTRUCTIONS
CLEARANCE (TYPICAL) AS REQUIRED BY MANUFACTURER'S
UL INSTALLATION INSTRUCTIONS
165° FUSIBLE LINK
DUCT TO SLEEVE CONNECTION SHALL BE AN APPROVED
TYPE AS LISTED IN THE MANUFACTURER'S UL INSTALLATION
INSTRUCTIONS. PROVIDE DUCT SEALANT APPROVED BY
FIRE DAMPER MANUFACTURER.
PROVIDE ACCESS PANEL FOR RECTANGULAR DUCTS. FOR ROUND DUCTS,
DOOR SIZE SHALL BE AS NOTED IN SPECIFICATIONS. FOR FLOOR
PENETRATIONS ACCESS PANEL SHALL BE ABOVE FLOOR.
FACTORY PROVIDED SLEEVE. SLEEVE LENGTH AND GAUGE SHALL
BE DETERMINED BY CONTRACTOR IN ACCORDANCE WITH
MANUFACTURER'S UL INSTALLATION INSTRUCTIONS.
FACTORY PROVIDED RETAINING ANGLES. ANGLE SIZE AND GAUGE
SHALL BE DETERMINED BY CONTRACTOR IN ACCORDANCE WITH
MANUFACTURER'S UL INSTALLATION INSTRUCTIONS.
GROUT
1" ABOVE FLOOR; FLUSH FOR WALLS
SCHEDULE 10 (MINIMUM)
STEEL PIPE
CONDUIT OR PIPING
PIPING INSULATION AS SPECIFIED.
PIPE INSULATION SHALL BE CONTINUOUS
THRU PENETRATION.
SEAL BETWEEN SLEEVE AND PIPING WITH FIRE RESISTANT
SEALANT OF SUFFICIENT THICKNESS TO MAINTAIN WALL'S
OR FLOOR FIRE RATING (1" MINIMUM THICKNESS). IF WALL
IS NOT FIRE RATED, PROVIDE CAULKING IN LIEU OF FIRE
RESISTANT SEALANT. SEALANT IS ONLY REQUIRED ON
ONE SIDE OF WALL, UNLESS REQUIRED BY MANUFACTURER
ON BOTH SIDES.
FIBERGLASS BATTS PACKED BETWEEN SLEEVE
AND PIPE (OR PIPE INSULATION ON INSULATED PIPE)
WALL OR FLOOR. CONTRACTOR SHALL VERIFY
CONSTRUCTION TYPE (MASONRY, CONCRETE,
BRICK AND CMU, ETC.) AND THICKNESS.
INSIDE
UNINSULATED REFRIGERANT LIQUID PIPE
REFRIGERANT PIPE DROPS
IN WALL AS REQUIRED
INSULATED REFRIGERANT
SUCTION PIPE
20 GAUGE GALVANIZED
STEEL SHEET METAL SLEEVE
TERMINATE SLEEVE
FLUSH WITH WALL
OUTSIDE
PIPE PENETRATES WALL
NEAR GRADE LEVEL
EXTERIOR PAINTABLE SILICON CAULK.
PAINT TO MATCH EXTERIOR. EXTERIOR WALL. SEE ARCHITECTURAL PLANS
FOR CONSTRUCTION
FIRE RESISTANT FOAM OF APPROPRIATE
THICKNESS TO MAINTAIN WALL'S FIRE RATING
(1" MINIMUM THICKNESS)
DIA. -",
(SEE PLANS)
3"
DIM. + ?"
DIM. + ?"
3"
PAINT INTERIOR OF BOX MATTE BLACK.1
2 MINIMUM 26 GAUGE GALV. SHEET METAL.
4 ADAPTER MAY BE FABRICATED BY CONTRACTOR OR PROVIDED BY CROWN
PRODUCTS MODEL #666 ADAPTER OR EQUAL.
PROVIDE 1/2" DUCT LINER ON RETURN DUCT
APPLICATIONS AND NO LINER ON EXHAUST APPLICATION.
NOTES: (THIS DETAIL ONLY)
CAULK AROUND FULL PERIMETER OF ANGLE
EACH SIDE OF WALL.
3" X 3", 22 GAUGE SHEET METAL ANGLE
AROUND PERIMETER OF DUCT EACH SIDE
OF WALL. ANCHOR TO WALL WITH
EXPANSION ANCHOR.
DUCT WRAP INSULATION WITH FSK JACKET.
INSULATION IS CONTINUOUS THROUGH WALL
OPENING.
ELEVATION SECTION
NOTE: DETAIL IS SIMILAR FOR
UNINSULATED DUCTS. SEE
SPECIFICATION FOR REQUIRED
INSULATION THICKNESS.
SEAL WITH VAPOR PROOF MASTIC AND CLOTH FABRIC
OVERLAPPING ANGLE AND DUCT WRAP FSK JACKET TO
PREVENT PASSAGE OF SMOKE.
CAULK AROUND FULL PERIMETER OF ANGLE
EACH SIDE OF WALL.
3" X 3", 22 GAUGE SHEET METAL ANGLE AROUND
PERIMETER OF DUCT EACH SIDE OF WALL.
ANCHOR TO WALL WITH EXPANSION ANCHOR.
DUCT WRAP INSULATION WITH FSK
JACKET.INSULATION IS CONTINUOUS
THROUGH WALL OPENING.
SEAL WITH VAPOR PROOF MASTIC AND CLOTH
FABRIC OVERLAPPING ANGLE AND DUCT WRAP
FSK JACKET TO PREVENT PASSAGE OF SMOKE.
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
GA DOE ID #: 2058
M502
MECHANICAL DETAILS
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
NOT TO SCALE
CENTRIFUGAL INLINE FAN DETAIL
NOT TO SCALE
CONDENSATE AUXILIARY DRAIN PAN DETAIL
NOT TO SCALE
EQUIPMENT SUPPORT PLATFORM DETAIL (HP)
NOT TO SCALE
EQUIPMENT SUPPORT RAIL DETAIL
NOT TO SCALE
FIRE DAMPER DETAIL
NOT TO SCALE
PIPE SLEEVE DETAIL
NOT TO SCALE
PIPE SLEEVE DETAIL - REFRIGERANT PIPE THRU EXTERIOR WALL
NOT TO SCALE
RECTANGULAR TO ROUND FLAT ADAPTER
NOT TO SCALE
DUCT PENETRATION THRU WALL DETAIL
INSIDEOUTSIDE
GRADE
EXTERIOR 22 GAUGE HOOD SHALL BE PAINT GRIP SHEET
METAL. ALL JOINTS AND SEAMS SHALL BE STANDARD
SMACNA CONSTRUCTION, AND SEALED NEATLY AND
WATERTIGHT. PAINT EXTERIOR DUCTWORK WITH 2 COATS
OF ENAMEL PAINT. VERIFY COLOR WITH ENGINEER.
HVAC
UNIT CAULK FULL WIDTH.
SEAL WEATHERTIGHT.
TURN CONNECTING DUCT UPWARD WITH 2"
FLANGE ON RTAC CONNECTION. CAULK FULL
PERIMETER OF DUCT.
1 LAYER OF EXTERIOR 2" THICK ARMACELL CLOSED
CELL ELASTOMERIC INSULATION OVER SUPPLY AND
RETURN DUCTWORK. FIBERGLASS INTERNAL DUCT
LINER OR EXTERNAL DUCT WRAP/BOARD IS NOT
ALLOWED ON THE DUCT. FINISH INSULATION WITH 2
COATS OF ARMACELL ARMAFLEX FINISH AND
EMBOSSED ALUMINUM COVER.
SEE PLANS FOR DUCT CONTINUATION.
NOTE: THE DUCT ROUTING SHOWN BETWEEN THE HVAC UNIT AND THE EXTERIOR WALL IS
SYMBOLIC IN THIS DETAIL AND DOES NOT INTEND TO INDICATE ALL ELBOWS, TRANSITIONS,
OFFSETS, ETC. SEE FLOOR PLANS FOR ACTUAL ROUTING.
CONCRETE EQUIPMENT PAD. SEE
CONCRETE EQUIPMENT PAD DETAIL.
22 GAUGE 3 SIDED METAL DUCT HOOD BETWEEN HVAC UNIT AND
EXTERIOR WALL. EXTEND BOTH SIDES OF SHEET METAL…
This is the start of the file's text. The full file is on GovTribe.
Other files
| File | Type | Posted |
|---|---|---|
| Addendum 3 | — | |
| Addendum 2 | — | |
| Bid Invitation | — | |
| Addendum 1 | — | |
| Award Information | — | |
| Addendum 4 | — |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .