This Addendum 2, dated June 6, 2022, modifies the original specifications and drawings for the Morningside Elementary School HVAC and Plumbing Upgrades project being undertaken by the Dougherty County Board of Education in Albany, Georgia. The addendum establishes modifications to three specification sections related to HVAC closeout documentation requirements, instrumentation and control systems, and particulate air filtration with bipolar ionization units. Three mechanical demolition plan drawings (MD101, MD102, and MD103) covering sectors A through E are revised and replaced in their entirety. The addendum includes a mandatory pre-bid meeting scheduled for June 23, 2022, at staggered times beginning at 12:45 p.m., with the location at 601 Flint Ave, Albany, Georgia. The pre-bid sign-in sheet documents attendance from multiple contractors and vendors representing various mechanical, electrical, and construction firms across the region.
Key specification changes include the replacement of HVAC closeout document requirements with a transfer form for spare parts and materials, specifically requiring the provision of one cylinder of R-410a refrigerant. New instrumentation requirements mandate that the direct digital control system monitor fault outputs from all bipolar ionization units, with alarms transmitted to the owner's control system. Additionally, all particulate filtration units must be equipped with dry contact output capability for building automation system fault condition monitoring. All bidders of record are required to acknowledge receipt of this addendum on the Bid Price Form, with failure to do so subject to disqualification from the procurement process.
Text of this file
Morningside Elementary School May 20, 2022
HVAC & Plumbing Upgrades
Dougherty County Board of Education
Albany, Georgia
Addendum No. 2- Page 1 of 2
ANDREWS, HAMMOCK & POWELL, INC. 250 CHARTER LANE, SUITE 100, MACON, GA 31210
ADDENDUM NUMBER: TWO DATED: June 6, 2022
To: All contract bidders of record.
This addendum forms a part of the Contract Documents and modifies the original Specifications and Drawings dated May 20, 2022, as noted below. Acknowledge receipt of this Addendum in the space provided on the Bid Price Form; failure to do so may subject bidder to disqualification.
GENERAL INFORMATION
1. A copy of the Pre-Bid Sign-in Sheet is included with this addendum.
CHANGES TO SPECIFICATIONS
1. SECTION 230514 - CLOSEOUT DOCUMENT REQUIRMENTS FOR HVAC
A. On page 230514-6, paragraph 1.11.A, delete the table in its entirety and replace with the following:
TRANSFER OF EXTRA MATERIALS AND SPARE PARTS
Spec Section Total Quantity
Received
Owner's
Rep. Initials
Date
Received
ADDITIONAL REFRIGERANT
Provide one (1) cylinder of R-410a refrigerant.
"I certify that the above list of spare parts and materials have been turned over to the Owners
Representative."
Company:
Name:
Title:
Signature:
Date:
2. SECTION 230900 - INSTRUMENTATION AND CONTROL FOR HVAC
A. On page 230900-16, add the following as paragraph 3.12.O.3.:
“3. Bipolar Ionization Unit Monitoring: DDC system shall monitor fault output of all bipolar ionization units. All alarms shall be sent to the Owner's control system.”
Morningside Elementary School May 20, 2022
HVAC & Plumbing Upgrades
Dougherty County Board of Education
Albany, Georgia
Addendum No. 2- Page 2 of 2
3. SECTION 234100 - PARTICULATE AIR FILTRATION AND BI-POLAR
IONIZATION UNITS
A. On page 234100-3, paragraph 2.3.A, add the following sentence before the last sentence of this paragraph.
“Unit shall be equipped with dry contact output capable of connection to BAS for monitoring a fault condition.”
CHANGES TO DRAWINGS
1. MD101 - MECHANICAL DEMO PLAN - SECTOR A & C
A. Delete Sheet MD101 in its entirety and replace with Sheet MD101, revised 06/06/2022, included herewith.
2. MD102 - MECHANICAL DEMO PLAN - SECTOR B
A. Delete Sheet MD102 in its entirety and replace with Sheet MD102, revised 06/06/2022, included herewith.
3. MD103 - MECHANICAL DEMO PLAN - SECTOR D & E
A. Delete Sheet MD103 in its entirety and replace with Sheet MD103, revised 06/06/2022, included herewith.
END OF ADDENDUM #2
Dougherty County School System - Facilities Services Department 1711 Schilling Avenue, Albany, Georgia 31705
Phone: (229) 431-1301 Fax: (229) 431-1252
Bid Number:
Bid Name:
Bid Date:
Bid Location:
NAME Prime COMPANY NAME PHONE EMAIL Tony Reese N/A DCSS Facilities 229-431-1301 treese@docoschools.org
Jake Andrews N/A Andrews, Hammock & Powell, Inc. 478-832-6372 jandrews@ahpengr.com
Jim Hughes N/A Andrews, Hammock & Powell, Inc. 478-832-6368 jhughes@ahpengr.com
Will Fox N/A Andrews, Hammock & Powell, Inc. 478-832-6383 wfox@ahpengr.com
Holden Parker N/A Andrews, Hammock & Powell, Inc. 478-832-6382 hparker@ahpengr.com
Bob Montgomery Yes Albany Air 229-894-0682 bmontgomery@albanyair.com
Rebecca Greer Yes Waters Mechanical 912-654-2829 rgreer@watersmechanical.net
Rick Newell Yes Newell Construction 229-347-3220 rick.newell@newellconstruction.com
Ashley Lang Yes Lang Mechanical 229-403-0645 clayton@langmechanical.org
Cole Sumner No ESS-Metro Power 229-206-0292 cole.sumner@metropower.com
Davy Youmans No Metro Power 229-357-1191 davy.youmans@metropower.com
Jayson Meyers Keith Lawson Company 850-879-3300 jayson@keithlawson.com construction@keithlawson.com
David Kolody No Metro Power Plumbing 229-439-5779 david.kolody@metropower.com
Clay Griffith Georgia Electric 229-869-6126 clay@geaelec.com
Bill Guin Yes SafeAire 229-343-5304 bguin@safeaire.com
Ricky Spence Yes SafeAire 229-343-5304 rspence@safeaire.com
Jason Griffin Johnson Electronics 229-869-9502 jason@jesystemsinc.com
601 Flint Ave, Albany Ga.
Mandatory Pre-Bid Sign-In Sheet 22-FAC-012, 22-FAC-013, 22-FAC-014, 22-FAC-015, 22-FAC-016, and 22-FAC-017 HVAC and Plumbing Upgrades at Alice Coachman, International Studies, Lamar Reese, MLK Jr., Morningside, and West Town Elementary Schools June 23, 2022 @ 12:45, 1:00, 1:15, 1:30, 1:45, 2:00, and 2:15 mailto:treese@docoschools.org mailto:jandrews@ahpengr.com mailto:jhughes@ahpengr.com mailto:wfox@ahpengr.com mailto:hparker@ahpengr.com mailto:bmontgomery@albanyair.com mailto:rgreer@watersmechanical.net mailto:rick.newell@newellconstruction.com mailto:clayton@langmechanical.org mailto:cole.sumner@metropower.com mailto:davy.youmans@metropower.com mailto:jayson@keithlawson.com mailto:jayson@keithlawson.com mailto:david.kolody@metropower.com mailto:clay@geaelec.com mailto:bguin@safeaire.com mailto:rspence@safeaire.com mailto:jason@jesystemsinc.com
Dougherty County School System - Facilities Services Department 1711 Schilling Avenue, Albany, Georgia 31705
Phone: (229) 431-1301 Fax: (229) 431-1252
Bid Number:
Bid Name:
Bid Date:
Bid Location:
NAME Prime COMPANY NAME PHONE EMAIL 601 Flint Ave, Albany Ga.
Mandatory Pre-Bid Sign-In Sheet 22-FAC-012, 22-FAC-013, 22-FAC-014, 22-FAC-015, 22-FAC-016, and 22-FAC-017 HVAC and Plumbing Upgrades at Alice Coachman, International Studies, Lamar Reese, MLK Jr., Morningside, and West Town Elementary Schools June 23, 2022 @ 12:45, 1:00, 1:15, 1:30, 1:45, 2:00, and 2:15
Mark Gordon No Gordon Electric Co. 229-436-9659 gordonr29@aol.com
Rod Carter No Flint River Construction 229-449-1343 flintrivercc@yahoo.com
Larry Griffin Yes LRA Constructors 229-349-2276 lgriffin@lraconstructors.com mailto:gordonr29@aol.com mailto:flintrivercc@yahoo.com mailto:lgriffin@lraconstructors.com
1 1 1 1 1 1
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
STOR.
CORR.
COMPUTER LAB
COMPUTER LAB
BOYS
GIRLS
1 1 1 1 1
11111
CLASSROOM
COMPUTER LAB
CLASSROOM
COMPUTER LAB
CLASSROOM
BOYS
GIRLS
CORRIDOR
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
MD101
MECHANICAL DEMO PLAN -
SECTOR A & C
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/8" = 1'-0"1 MECHANICAL DEMO PLAN - SECTOR A
1/8" = 1'-0"2 MECHANICAL DEMO PLAN - SECTOR C
1 . REMOVE EXISTING WALL HUNG HEAT PUMP AND ASSOCIATED DISCONNECT. SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW WALL HUNG HEAT PUMP SAME LOCATION.
2 . REMOVE EXISTING CEILING HEATER FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR CEILING HEATER REPLACEMENT.
3 . REMOVE EXISTING PACKAGED ROOF TOP UNIT FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR RTU REPLACEMENT. SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW UNIT.
4 . REMOVE EXISTING ROOF EXHAUST FAN FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN REPLACEMENT.
NOTES: (THIS SHEET ONLY)
GENERAL NOTE: OWNERSHIP OF ALL REMOVED EQUIPMENT NOT RETAINED BY
THE OWNER SHALL BECOME PROPERTY OF THE CONTRACTOR. COORDINATE
WITH OWNER FOR SALVAGE OF ANY EQUIPMENT TO BE RETAINED BY THE OWNER.
No. Description Date
1 ADDENDUM #2 06/06/22
COMPUTER LAB
CLASSROOM
CORRIDOR
CLASSROOM
CLASSROOM
CAFETERIA
STAGE
DISH WASH
FREEZER
COOLER
VEST.
FOOD STORAGE
CORRIDOR
8 8
91010
11 11
5 5(TYP) (TYP)
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
MD102
MECHANICAL DEMO PLAN -
SECTOR B
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/8" = 1'-0"1 MECHANICAL DEMO PLAN - SECTOR B
NOTES: (THIS SHEET ONLY)
1 . REMOVE EXISTING WALL HUNG HEAT PUMP AND ASSOCIATED DISCONNECT. SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW WALL
HUNG HEAT PUMP SAME LOCATION.
2 . REMOVE EXISTING CEILING HEATER FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR CEILING HEATER REPLACEMENT.
3 . REMOVE EXISTING PACKAGED ROOF TOP UNIT FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR RTU REPLACEMENT. SALVAGE EXISTING GPS
BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW UNIT.
4 . REMOVE EXISTING ROOF EXHAUST FAN FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN REPLACEMENT.
5 . (TYPICAL) EXISTING SUPPLY/RETURN/EXHAUST GRILLE AND ASSOCIATED FLEX DUCT (IF APPLICABLE) IN THIS APPROXIMATE LOCATION TO REMAIN FOR REUSE. SEE
NEW WORK DRAWING FOR AIRFLOW.
6 . REMOVE EXISTING CEILING EXHAUST FAN FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN REPLACEMENT.
7 . REMOVE EXISTING KITCHEN HOOD EXHAUST FAN ON ROOF IN THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN REPLACEMENT.
8 . REMOVE EXISTING AIR HANDLER FROM THIS APPROXIMATE LOCATION. DUCTWORK TO REMAIN FOR REUSE WITH NEW UNIT. REMOVE ALL ASSOCIATED REFRIGEREANT PIPING FROM OUTDOOR UNIT TO INDOOR UNIT. CONDENSATE PIPE TO REMAIN FOR REUSE WITH NEW UNIT. REMOVE EXISTING BIPOLAR UNIT IN
EXISTING UNIT FOR REUSE IN NEW UNIT.
9 . REMOVE EXISTING HEAT PUMP FROM THIS APPROXIMATE LOCATION. CONCRETE EQUIPMENT PAD AND FENCE TO REMAIN FOR REUSE WITH NEW UNIT. REMOVE ALL
ASSOCIATED REFRIGEREANT PIPING FROM OUTDOOR UNIT TO INDOOR UNIT.
10 . EXISTING RETURN DUCT TO REMAIN IN THIS APPROXIMATE LOCATION. OPEN MANUAL VOLUME DAMPER ALL THE WAY TO ALLOW FULL AIRFLOW.
11 . EXISTING LOUVER, DUCTWORK, AND AUTOMATIC VOLUME DAMPER TO REMAIN FOR REUSE. REMOVE ACTUATOR. SEE NEW WORK DRAWINGS FOR INSTALLATION OF
NEW ACTUATOR AND MANUAL VOLUME DAMPER.
12 . EXISTING DISHWASHER EXHAUST FAN TO REMAIN.
13 . EXISTING DUCTWORK IN MECHANICAL ROOM AND ON ROOF TO REMAIN.
14 . EXISTING GRAVITY VENT ON ROOF. CAP AND SEAL VENT AIR TIGHT.
15 . REMOVE ALL EXISITNG DUCTWORK PAST THE SCOPE OF WORK SYMBOL. SEE NEW WORK DRAWINGS FOR NEW DUCTWORK. PROVIDE DUCT END CAP.
16 . REMOVE EXISTING CEILING DIFFUSER IN THIS APPROXIMATE LOCATION.
GENERAL NOTE: OWNERSHIP OF ALL REMOVED EQUIPMENT NOT RETAINED BY
THE OWNER SHALL BECOME PROPERTY OF THE CONTRACTOR. COORDINATE
WITH OWNER FOR SALVAGE OF ANY EQUIPMENT TO BE RETAINED BY THE OWNER.
No. Description Date
CLASSROOM
6 6
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
11 (TYP)
11 (TYP)
11 (TYP)
11 (TYP)11 (TYP)11 (TYP)
11 (TYP)
(TYP)12 12 12 12 12 12
121212121212
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
TITLE:
SUBJECT TO GENERAL
COPYRIGHT LAWS ©
REVISIONS
A
B
C
D
E
GA DOE ID #: 2058
MD103
MECHANICAL DEMO PLAN -
SECTOR D & E
2021201
M O
R N
IN
G
S
ID
E E
L E
M E
N T
A R
Y S
C H
O O
L
H V
A C
P
L U
M B
IN
G
U P
G R
A D
E S
05/20/2022
HHP
JA3
S U
N S
E T
L N
A
L B
A N
Y
G A
1/8" = 1'-0"1 MECHANICAL DEMO PLAN - SECTOR D
1 . REMOVE EXISTING WALL HUNG HEAT PUMP AND ASSOCIATED DISCONNECT. SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR
INSTALLATION IN NEW WALL HUNG HEAT PUMP SAME LOCATION.
2 . REMOVE EXISTING CEILING HEATER FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR CEILING HEATER REPLACEMENT.
3 . REMOVE EXISTING PACKAGED ROOF TOP UNIT FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR RTU REPLACEMENT.
SALVAGE EXISTING GPS BIPOLAR IONIZATION UNIT FOR INSTALLATION IN NEW UNIT.
4 . REMOVE EXISTING ROOF EXHAUST FAN FROM THIS APPROXIMATE LOCATION. SEE NEW WORK DRAWING FOR EXHAUST FAN
REPLACEMENT.
5 . REMOVE EXISTING PACKAGED HEAT PUMP UNITS FROM THIS APPROXIMATE LOCATION. DEMO DUCTWORK AND DUCT COVERING UP TO CHASE TO ALLOW FOR NEW DUCTWORK CONNECTION. REMOVE EXISTING BIPOLAR IONIZATION UNIT FOR REUSE IN NEW PACKEGED UNIT.
6 . (TYPICAL) EXISTING DUCTWORK TO REMAIN.
7 . REMOVE EXISTING RETURN GRILLE FROM CEILING IN THIS APPROXIMATE LOCATION.
8 . REMOVE EXISTING ROOF VENTILATOR FROM THIS APPROXIMATE LOCATION. CAP EXISTING CURB.
9 . REMOVE EXISTING AIR HANDLER AND ALL ASSOCIATED PIPING, SUPPORTS, DUCTWORK, ETC. FROM THIS APPROXIMATE LOCATION.
10 . REMOVE ANY AND ALL HVAC RELATED ITEMS FROM MECHANICAL ROOM. THIS INLCUDES BUT IS NOT LIMITED TO, AIR COMPRESSOR, DUCTOWKR, PIPING, BOILER, CONTROLS, ETC.
11 . REMOVE EXISTING DUCTWORK.
12 . REMOVE EXISTING SIDE WALL GRILLE.
13 . REMOVE EXISTING CONDENSING UNIT ON ROOF. DEMO ANY ASSICIATED ELECTRICAL AND PIPING MATERIALS. SEAL ALL ROOF OPENINGS.
NOTES: (THIS SHEET ONLY)
GENERAL NOTE: OWNERSHIP OF ALL REMOVED EQUIPMENT NOT RETAINED BY
THE OWNER SHALL BECOME PROPERTY OF THE CONTRACTOR. COORDINATE
WITH OWNER FOR SALVAGE OF ANY EQUIPMENT TO BE RETAINED BY THE OWNER.
1/8" = 1'-0"2 MECHANICAL DEMO PLAN - SECTOR E
No. Description Date
| 22-FAC-016_Addendum No. 2_06062022 |
| Pre-Bid Sign In Sheet_06022022 |
| Pre-Bid Sign-In |
| Mechanical Drawings |
| Sheets |
| MD101 - MECHANICAL DEMO PLAN - SECTOR A & C |
| MD102 - MECHANICAL DEMO PLAN - SECTOR B |
| MD103 - MECHANICAL DEMO PLAN - SECTOR D & E |
Other files
| File | Type | Posted |
|---|---|---|
| Bid Invitation | — | |
| Addendum 1 | — | |
| Addendum 3 | — | |
| DRAWINGS | — | |
| Award Information | — | |
| Addendum 4 | — |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .