Drawings 17185_Part4.pdf

PDF 1 MB Posted

Attached to
751/17185. JBB; Eagle Harbor State Harbor - Harbor Upgrades
Solicitation number
RFQ 171 220000000407 4
Issued by
Kent County, Douglas City, Michigan

About this file

This is a technical drawing document (Sheet 17185_Part 4) produced by Edgewater Resources, LLC for an electrical project at Eagle Harbor in Michigan under the jurisdiction of the Department of Natural Resources (MDNR) and the Department of Technology, Management & Budget (DTMB). The project, identified as PROJ NO. 751/17185.JBB, involves the design and installation of electrical systems at a marine facility. The drawings serve as schematic illustrations of minimum electrical requirements intended for bidding purposes, with the electrical contractor responsible for final system design and compliance with the 2020 National Electrical Code (N.E.C.) and Michigan Electrical Code. Key specifications include requirements for continuous wire runs without splices, all connections positioned at least 12 inches above the deck and electrical datum plane per N.E.C. Article 555, and coordination between the electrical contractor and other trades regarding installation timelines.

The electrical system specifications include utility pedestals equipped with one 20-ampere, 125-volt duplex GFCI maintenance receptacle for each slip and 30-milliampere GFPE ground fault protection for each shore power receptacle, with trip levels set at 25-30 milliamperes and trip timing specifications. The contractor is responsible for all take-offs, means and methods allowances, and circuit length calculations for bidding purposes, with circuit lengths on the drawings representing distances between connection points only. One-line diagrams are referenced on Sheet E-6.02 for additional electrical system details. No pricing information, funding sources, or contract award details are provided in this technical drawing document.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DATE:

DESIGNED BY:

DRAWN BY:

REVIEWED BY:

SHEET NUMBER:

THE REPRODUCTION, COPYING OR

OTHER USE OF THIS DRAWING WITHOUT

WRITTEN CONSENT IS PROHIBITED.

© 2022 EDGEWATER RESOURCES, LLC.

ISSUED FOR:

DATE REVISION

PR

O

JE

C

T

TI

TL

E:

SH

EE

T

TI

TL

E:

518 Broad Street, Suite 200 Saint Joseph, MI 49085

P: 269.932.4502 edgewaterresources.com

PROJ NO.:

751/17185.JBB

DTMB PROJ. NO.

NORTH

P:\2017\17-37 MDNR - EAGLE HARBOR\CAD\SHEETS\E-X.XX.DWG

ELECTRICAL NOTES:

1. ELECTRICAL SCHEDULES SHOWN HEREIN ARE SCHEMATIC AND ARE INTENDED TO ILLUSTRATE MINIMUM ELECTRICAL REQUIREMENTS FOR BIDDING

PURPOSES. CONTRACTOR IS RESPONSIBLE FOR FINAL DESIGN OF THE ELECTRICAL SYSTEM. SYSTEM SHALL BE COMPLIANT WITH 2020 N.E.C. AND

MICHIGAN ELECTRICAL CODE AT MINIMUM.

2. CIRCUIT LENGTHS SHOWN TO REPRESENT DISTANCES BETWEEN CONNECTION POINTS, CONTRACTOR RESPONSIBLE FOR THEIR OWN TAKE OFFS AND

MEANS & METHODS ALLOWANCES FOR BIDDING.

3. SEE SHEET E-6.02 FOR ONE-LINE-DIAGRAMS.

4. ALL WIRE RUNS SHALL BE CONTINUOUS WITH NO SPLICES. ALL CONNECTIONS SHALL BE AT LEAST 12" ABOVE THE DECK AND ABOVE THE ELECTRICAL

DATUM PLANE PER N.E.C. ARTICLE 555.

5. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES REGARDING INSTALLATION TIMELINES.

6. ALL UTILITY PEDESTALS SHOULD INCLUDE 1-20a 125V DUPLEX GFCI MAINTENANCE RECEPTACLE FOR EACH SLIP.

7. ALL UTILITY PEDESTALS TO INCLUDE 30mA GFPE GROUND FAULT PROTECTION FOR EACH SHORE POWER RECEPTACLE. GFPE CONTROLS SHALL HAVE

A TRIP LEVEL OF 25-30mA AND A TRIP TIMING OF <200ms WHEN TESTED. ALL BRANCH LINES TO BE PROTECTED BY 100mA GROUND FAULT PROTECTION AT THE PANEL. PANEL TO INCLUDE A BENDER RCMS 490 GROUND FAULT MONITOR TO CONTROL THE BRANCH CIRCUITS. ALL GROUND FAULT CONTROLS TO BE TESTED AND DOCUMENTED TO SHOW ACTUAL TRIP LEVELS ARE BELOW THE RESPECTIVE 6mA, 30mA, AND 100mA CRITERIA PRIOR TO ACCEPTANCE. ANY EQUIPMENT NOT MEETING ACCEPTABLE TOLERANCES SHALL BE REPLACES AT NO ADDITIONAL COST TO OWNER.

8. CONTRACTOR TO PROVIDE WATER TIGHT FLEXIBLE CONDUIT WATERWARD OF SEAWALL INTERFACE TO ACCOMODATE DOCK SETTLEMENT.

9. CONTRACTOR TO VERIFY ALL CONDUIT BURY DEPTHS PER MICHIGAN ELECTRICAL CODE.

10. ALL GROUNDS SHALL BE INSULATED, GROUNDING SHALL BE PER MICHIGAN ELECTRICAL CODE AND N.E.C.

1 PANEL A SCHEDULE

SCALE: NTS

2 PANEL B SCHEDULE

SCALE: NTS

EL

EC

TR

IC

AL

S

C H

ED

U

LE

EA

G

LE

H

AR

BO

R , M

I H

AR

BO

R U

PG

R

AD

ES

EA

GL

E

HA

RB

OR

S

TA

TE

H

AR

BO

R

E-6.01

CH

SH

CH

17-37

6/10/2022

AS NOTED

BID

SCALE:

CT CABINET AND METER DETAIL

1/2"=1'-0" DT-CABINET AND METER

TREATED TIMBER 2X6

DECKING (TYP.)

UTILITY CT CABINET

METER BASE

TREATED TIMBER 2X6 BRACE

TREATED 4X4 TIMBER POST

CONCRETE BASE, FOUNDATION

COAT POSTS

CONDUIT FROM TRANSFORMER

(BY UTILITY)

CONDUIT TO MDP (PER

SCHEDULE)

EXISTING GRADE

6'- 0"

M

AX

4'-

0"

2'- 0"

NOTE:

· INCLUDE ALL GROUNDING AND

BONDING REQUIRED PER N.E.C.

· COORDINATE ALL WORK "BY

UTILITY" WITH UTILITY

SCALE:

DATE:

DESIGNED BY:

DRAWN BY:

REVIEWED BY:

SHEET NUMBER:

THE REPRODUCTION, COPYING OR

OTHER USE OF THIS DRAWING WITHOUT

WRITTEN CONSENT IS PROHIBITED.

© 2022 EDGEWATER RESOURCES, LLC.

ISSUED FOR:

DATE REVISION

PR

O

JE

C

T

TI

TL

E:

SH

EE

T

TI

TL

E:

518 Broad Street, Suite 200 Saint Joseph, MI 49085

P: 269.932.4502 edgewaterresources.com

PROJ NO.:

751/17185.JBB

DTMB PROJ. NO.

NORTH

P:\2017\17-37 MDNR - EAGLE HARBOR\CAD\SHEETS\E-X.XX.DWG

EL

EC

TR

IC

AL

O

N E-

LI

N

E D

IA

G

R

AM

EA

G

LE

H

AR

BO

R , M

I H

AR

BO

R U

PG

R

AD

ES

EA

GL

E

HA

RB

OR

S

TA

TE

H

AR

BO

R

E-6.02

CH

SH

CH

17-37

6/10/2022

AS NOTED

BID

M

500A 2P

NEW UNDERGROUND FEED BY UTILITY

NEW 120 kVA, 120/240V SEC. TRANSFORMER

BY UTILITY

SECONDARY WIRE & CONDUIT

BY UTILITY

NEW CT CABINET MOUNTED TO TIMBER

FRAME

NEW 600A METER BASE MOUNTED TO

TIMER FRAME, COORDINATE WITH UTILITY

ON MOUNTING REQUIREMENTS

NEW EAST MARINA MDP

200A ST

2P

200A ST

2P

200A ST

2P

EAST MARINA

CIRCUIT B-1

EAST MARINA

CIRCUIT B-2

EAST MARINA

CIRCUIT B-3

2"C, 3-#4/0

W/ 1-#4 GND*

2"C, 3-#3/0

W/ 1-#4 GND*

2"C, 3-#3/0

W/ 1-#4 GND

* PROVIDE WATER-TIGHT FLEXIBLE CONDUIT AT

SEAWALL PENETRATIONS FOR CRIB PIERS TO

ALLOW FOR DOCK SETTLEMENT

3-2"C, 3-#3/0

W/ 1-#2/0 GND

1 EAST MARINA ONE-LINE DIAGRAM

SCALE: NTS

2 WEST MARINA ONE-LINE DIAGRAM

SCALE: NTS

M

20A 1P

20A 1P

20A 2P

30A 2P

100A ST

2P

100A ST

2P

100A ST

2P

300A MAIN

2P

WEST MARINA

CIRCUIT A-3

WEST MARINA

CIRCUIT A-2

WEST MARINA

CIRCUIT A-1

EXISTING BUILDING

LIGHTING

EXISTING BUILDING

OUTLETS

EXISTING WELL

PUMP

EXISTING WATER

HEATER CIRCUIT

NEW PANEL IN BUILDING,

REPLACE EXISTING

RECONNECT EXISTING CIRCUITS

TO NEW PANEL

EXISTING #4/0 SERVICE FROM UTILITY TO

REMAIN, CONNECT TO NEW METERBASE W/

NEW CONDUIT ABOVE GRADE

NEW 300A, 600V METER BASE TO REPLACE

EXISTING UNIT ON EXTERIOR OF BUILDING

1-1/2"C, 3-#3

W/ 1-#6 GND

1-1/2"C, 3-#3

W/ 1-#6 GND

1-1/2"C, 3-#2

W/ 1-#6 GND

20A 2P

BASEBOARD HEAT

CIRCUIT 1/2" C,

3-#12 W/ 1-#12 GND

K-3531WELLWORTHTOILETVITREOUS CHINA

K-3531WELLWORTHTOILETVITREOUS CHINAK-3531WELLWORTH TOILETVITREOUS CHINA

A-4.01

A-4.01

101 102

B

B

A

A A

B

B

AB

B B

B

A-4.018A-4.01 8

SIM.

K-3531WELLWORTHTOILETVITREOUS CHINA

NORTH

DATE:

DESIGNED BY:

DRAWN BY:

REVIEWED BY:

SHEET NUMBER:

THE REPRODUCTION, COPYING OR

OTHER USE OF THIS DRAWING WITHOUT

WRITTEN CONSENT IS PROHIBITED.

© 2022 EDGEWATER RESOURCES, LLC.

ISSUED FOR:

DATE REVISION

PR

O

JE

C

T

TI

TL

E:

SH

EE

T

TI

TL

E:

518 Broad Street, Suite 200 Saint Joseph, MI 49085

P: 269.932.4502 edgewaterresources.com

PROJ NO.:

751/17185.JBB

DTMB PROJ. NO.

P:\2017\17-37 MDNR - EAGLE HARBOR\CAD\SHEETS\A-X.XX.DWG

SCALE: 1/4" = 1'-0"1 EXISTING FLOOR PLAN

GENERAL NOTES:

1. ALL CONSTRUCTION TO BE IN COMPLIANCE WITH THE MOST CURRENT ADOPTED STATE OF MICHIGAN BUILDING, MECHANICAL, PLUMBING, ELECTRICAL AND ENERGY CODES, ADA GUIDELINES, LOCAL ZONING ORDINANCES AND SUBMITTED TO THE MICHIGAN DEPARTMENT OF LICENSING AND REGULATORY CODES

(LARA) FOR ALL BUILDING PERMITS PRIOR TO COMMENCEMENT OF CONSTRUCTION.

2. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL EXISTING BUILDING AND SITE DIMENSIONS AND CONDITIONS INCLUDING UNDERGROUND UTILITIES, FOUNDATION AND ROOF STRUCTURE PRIOR TO

DEMOLITION AND ADVISE OWNER, ENGINEER AND ARCHITECT OF UNSEEN OR UNEXPECTED

CONDITIONS THAT COULD COMPROMISE THE COST OR SCHEDULE OF THE PROPOSED DESIGN INTENT.

3. EXISTING ROOF DESIGN LOADING ASSUMED PER 2015 MICHIGAN BUILDING CODE:

LIVE LOAD = 50 PSF, DEAD LOAD = 20 PSF, GROUND SNOW LOAD = 100 PSF.

4. ALL MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS, WIRING, PIPING, FIXTURES, APPARATUS, AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS

AND WARRANTY.

5. CONTRACTOR SHALL APPLY RECEIVE AND PAY FOR ALL PERMITS, FURNISH PROOF OF PERMITS BEFORE STARTING WORK & FURNISH FINAL INSPECTION CERTIFICATES, AND COMPLY WITH PERMIT AND

CODE REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER.

6. CONTRACTOR SHALL ENSURE TRANSFERABLE WARRANTY FOR ALL WARRANTED ITEMS.

7. CONTRACTOR WILL PROVIDE SHOP DRAWINGS OF ALL EQUIPMENT, SYSTEMS, FIXTURES FINISHES AND

APPARATUS TO THE ARCHITECT AND OWNER FOR APPROVAL PRIOR TO ORDERING AND INSTALLATION.

8. PROVIDE CUT SHEETS OF ALL PROPOSED CAULK MATERIALS TO BE INSTALLED PER MFR

INSTRUCTIONS AND PROPOSED CONDITIONS AT EACH LOCATION

9. PROVIDE ALL WARRANTY INFORMATION, INSTRUCTIONS AND MATERIAL/FIXTURE DOCUMENTS TO

OWNER

10. DO NOT SCALE DRAWINGS. ALL DIMENSIONS ARE TO FACE OF STUD, CMU OR CENTER LINE OF

CONCRETE, STRUCTURE OR FOOTINGS UNLESS NOTED OTHERWISE

NEW CONSTRUCTION, TYPICAL WALL ASSEMBLY

NEW WALLS: 2 x 4 WD STUDS @ 16" O.C. w/ 5/8" GYP BOARD ON DRY SIDE. INSTALL VAPOR BARRIER

AND CEMENTITIOUS BACKER BOARD AT SHOWER SIDE.

PLUMBING FIXTURES:

SHOWER SURROUND AND SHOWER BASE:

SURROUND: SWANSTONE SERIES SK-366272 36" x 60" x 72" BATH WALL KIT TRIM TO FIT SHOWER

PAN OR EQUAL

SH. PAN 1: SWANSTONE SBF-3462, PERFORMIX ROLL-IN SHOWER PAN 32" x 60" OR EQUAL SH. PAN 2: SWANSTONE SS-3260 SINGLE THRESHOLD 32" x 60" OR EQUAL

WC-1 & 2: ADA COMPLIANT WALL MOUNTED WATER CLOSET AMERICAN STANDARD

"AFWALL" OR EQUAL

LAV-1: ADA COMPLIANT WALL MOUNTED LAV SINK , AMERICAN STANDARD "LUCERNE" OR EQUAL

KOHLER SERVICE SINK "K-6714" CAST IRON WALL MOUNT OR EQUAL

FAUCETS: RESTROOM FAUCETS: DELTA "C-SPOUT", SINGLE HANDLE DECK MOUNT #583LF-WF

SERVICE SINK FAUCET : KOHLER 'K-8907" OR EQUAL

LIGHTING FIXTURES - REMOVE AND REPLACE INTERIOR WALL MOUNTED

LIGHTING FIXTURES W/ WALL MOUNTED LED FIXTURES ON EXISTING SWITCHES. REPAIR AS NOTED FIXTURE SPECIFICATION: 48" WALL MOUNTED LED LITHONIA, 4000K , 19 WATTS, 2000 LUMENS, 120-277V

MEN'S

RESTROOM

SCALE: 1/4" = 1'-0"2 DEMOLITION FLOOR PLAN

SCALE: 1/4" = 1'-0"3 PROPOSED FLOOR PLAN

SCALE: 1/4" = 1'-0"4 EXISTING SOUTH ELEVATION

SCALE: 1/4" = 1'-0"5 EXISTING EAST ELEVATION

SCALE: 1/4" = 1'-0"6 EXISTING NORTH ELEVATION

SCALE: 1/4" = 1'-0"7 EXISTING WEST ELEVATION

WOMEN'S

RESTROOM

STAFF

OFFICE

MECHANICAL

ROOM

CONCRETE SIDEWALK

2'-

4"

'-4

2'- 4"

8" 9'-

1"

8"

'-3

3'- 2"

2'- 8"

4'- 1"

2'- 8"

4'- 1"

2'- 8"

8"

2'-4"21'-4"2'-3"

8"3'-4"12'-0"3'-4"1'-4"

21'-4"

8" 3'-4" 2'-0" 2'-8" 5'-4" 2'-8" 3'-4"

REMOVE ALL DOORS.

REPLACE W NEW TO

MATCH EXISTING.

TYPICAL ELEMENTS TO

BE REMOVED

EXISTING EXTERIOR AND

INTERIOR WALLS TO

REMAIN

REMOVE AND

REPLACE WATER

PRESSURE TANK

REMOVE AND

REPLACE SERVICE SINK

UNISEX

RESTROOM #1

BOATER'S

LOUNGE

MECHANICAL

ROOM

REMOVE CONCRETE SIDEWALK

EXISTING BUILDING DEMOLITION AND REPLACEMENT IN SAME OPENINGS TO

INCLUDE BUT NOT BE LIMITED TO:

REMOVE ALL PLUMBING FIXTURES AND TOILET/SHOWER

PARTITIONS. REPLACE w/ NEW PER PLANS. PATCH AND REPAIR

WALLS AND FLOOR AS REQUIRED TO ACCEPT NEW MATERIALS.

REMOVE WINDOWS AND REPLACE w/ NEW OPERABLE WHITE, COMMERCIAL ALL VINYL WINDOWS IN EXISTING OPENINGS.

INSTALL NEW LP SMART SIDE SYSTEM OF WOOD CASING, SILL

AND EXTERIOR TRIM.

REMOVE ALL DOORS AND FRAMES.

**NOTE** LEAD BASED PAINT AND ASBESTOS CAULK REMOVAL

MUST FOLLOW HAZARDOUS MATERIAL TESTING AND REMOVAL

PROCEDURES

REPLACE DOORS AND FRAMES WITH NEW FIBERGLASS DOORS

AND FRAMES PAINTED GREEN TO MATCH BOATHOUSE. REVERSE

SWING DOORS 101 AND 102 FOR BARRIER FREE FLOOR CLEARANCE.

INSTALL ADA COMPLIANT HARDWARE AND THRESHOLD.

RESTROOM / BOATER'S LOUNGE LOCKS TO BE KEYLESS w/ PUSH BUTTON LOCK w/ OCCUPANCY INDICATOR AT RESTROOMS. ALL

OTHERS TO MATCH EXISTING KEY SYSTEM

EXTERIOR ELEVATIONS TYPICAL NOTES:

EXISTING ROOF TO REMAIN. INSPECT FOR LEAKING AND REPORT

ANY FINDINGS TO OWNER AND ARCHITECT

REMOVE AND REPLACE EAVE FASCIA w/ LP SMART SIDE WHITE

FASCIA **NOTE** FOLLOW LEAD PAINT FINDINGS AND REMOVAL

PROCEDURE FOR HAZARDOUS MATERIALS

INSTALL NEW, PRE-FINISHED, LP SMART SIDE 6" LAP SIDING w/ 4"

CORNER BOARDS, DOOR AND WINDOW TRIM AND NEW FASCIA

SIZED TO MATCH EXIST. FASCIA IN "SNOW WHITE"

INSTALL SIDING ON TREATED, 2 x 4 VERTICAL WD FURRING ATTACHED AND ADHERED TO EXISTING CMU WALLS w/ AIR AND

MOISTURE BARRIER OVER FURRING AND DIRECTLY BEHIND SIDING.

INSTALL PER MFR WARRANTY AND INSTRUCTIONS

REMOVE AND REPLACE POTABLE WATER PRESSURE TANK

REMOVE AND REPLACE ELECTRICAL PANELS AND METER BASES

BARRIER-FREE

UNISEX

RESTROOM #2

EXISTING TO BE REMOVED

EXIST. WD FRAMED WALL

TO REMAIN - PATCH AND

REPAIR AS REQ'D

EXISTING CMU TO REMAIN

PATCH AND REPAIR AS REQ'D

NEW 2 x 4 WD FRAMED

SHOWER WALL

WALL TYPE LEGEND

BUILDING CODE OR LATEST ADOPTED FOR STATE OF MICHIGAN MUNICIPALITY:

2015 MICHIGAN REHABILITATION CODE (MRC)

2015 MICHIGAN BUILDING CODE (MBC)

2015 MICHIGAN PLUMBING AND MECHANICAL CODES

2014 MICHIGAN ELECTRICAL CODE

2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

ASHRAE STANDARD 90.1 v 2013 (ASHRAE)

2015 MICHIGAN UNIFORM ENERGY CODE (MUEC)

BARRIER FREE DESIGN: MICHIGAN PUBLIC ACT 1 OF 1966 & MBC, CHP 11

EXISTING BUILDING:

MUNICIPALITY STATE OF MICHIGAN

BUILDING GROSS AREA 455 SF

USE GROUP B - BUSINESS MBC 304

BUILDING TYPE II-B MBC TABLE 601

2015 MICHIGAN REHABILITATION CODE (MRC)

EXISTING BUILDING INTERIOR AREAS OF RENOVATION: 360 SF

MICHIGAN REHABILITATION CODE ALTERATION LEVEL 1 MRC 503

REMOVAL AND REPLACEMENT:

ENERGY CONSERVATION TO COMPLY w/ IECC MRC 708.1

CLIMATE ZONE #7 IECC 301.1/ ASHRAE TABLE D-1

COMMERCIAL BUILDINGS COMPLY w/ ASHRAE 90.1 v2013 MBC 1301.1/ MUEC C501.1 ( NEED NOT COMPLY w/IECC C402, C403, C404 & C405) / IECC C503.1

ENTIRE BUILDING NOT REQUIRED TO COMPLY: MRC 708.1 / IECC C503.1

ALTERATIONS SHALL CONFORM AS THEY RELATE TO NEW

CONSTRUCTION W/O REQUIRING UNALTERED PORTIONS TO COMPLY

BUILDING ENVELOPE NEED NOT COMPLY ASHRAE 5.1.3 &

THE FOLLOWING ALTERATIONS NEED NOT COMPLY PER EXCEPT #4 MUEC C506.1.4

ALTERATIONS TO WALLS AND FLOOR WHERE THE EXIST. STRUCTURE

IS WITHOUT FRAMING CAVITIES AND NO NEW CAVITIES ARE CREATED

& EXCEPTION #8 FOR REPLACED FENESTRATION < 25% TOTAL AREA FENESTRATION

NEW BASEBOARD HEAT ADDED TO UNCOND. SPACE WILL COMPLY MBC 1204.1 / ASHRAE 6.3.1

VENTILATION EQUIP TO BE REPAIRED OR REPLACED w/ SAME ASHRAE 6.1.1.3

BUILDING OCCUPANCY MBC 1004.1.2

RESTROOMS: 190 SF/50 4 OCCUPANTS

BOATER'S LOUNGE: 84 SF/100 1 OCCUPANTS

UTILITIES/STORAGE: 86 SF /300 1 OCCUPANTS

350 SF 6 TOTAL OCCUPANTS

BUILDING DATA

SCALE: NTS

ADA DESIGN GUIDELINES

" M

AX

36" MIN 6"

"-3

6"

"-3

6"

"-1 9"

TOILET LAVATORY

TOILET LAVATORY

ROLL IN SHOWER

6" MAX

6" M

AX

" M

IN

" M

IN

60" MIN

" M

IN

1'-

0"

6" 36" MIN

1'-6"

60" MIN 56

" M

IN

30" MIN

" M

INCL

" M

IN 24" MIN

12" MIN 48

" M

IN

" M

IN

18" MIN

24" MIN 42

" M

IN

DOOR CLEARANCES

NEW ELEC PANEL

CONSOLIDATE EXTERIOR

WALL MOUNTED METERS TO

A SINGLE METER

AR

C

H

IT

EC

TU

R

AL

S H

EE

T

EA

G

LE

H

AR

BO

R , M

I H

AR

BO

R U

PG

R

AD

ES

EA

GL

E

HA

RB

OR

S

TA

TE

H

AR

BO

R

A-1.01

CH

MMR

MMR

17-37

6/10/2022

AS NOTED

BID

REMOVE AND REPLACE

ELECTRICAL PANELS AND

METER BASES PER SHEET

E - 6.01

5'-

0" 5'-

0"

(FURNITURE N.I.C)

3 1 2 "

5'- 0"

5'-

0"

4'-6" 4'-10"4'-6"4'-101 2"

20'-0"

'-0

EXISTING EXTERIOR AND

INTERIOR WALLS TO REMAIN

NEW RECESSED LED SOFFIT

LIGHTS ON PHOTO SENSOR

INSTALL FURRING AND

SIDING PER PLANS

7"-9"

" M

IN 39

"-4

1"

" M

IN

11 2"

MI

N

TOILET SHOWER

27" MAX

CONTROLS

NOTE: INSTALL NEW WATER RESISTANT GYP

BD ON EXISTING WALLS AT SHOWER LOCATION

NEW 2 x 4 WD FRAMED SHOWER WALLS

LOCATE PLUMBING

ACCESS IN EXIST.

WALL PER OWNER

INSTALL NEW SHOWER

CURTAIN AND ROD

@ EACH SHOWER

ELEC. BASEBOARD

HEATER (TYP)

2" MAX HIGH

THRESHOLD

" M

IN

" M

AX

6" MAX 36" MIN

" M

AX

3'-

0"

2'-0"

39" - 41"

ELECTRICAL POWER - REMOVE AND REPLACE POWER PANELS PER SCHEDULES. NEW CIRCUITS PER NEC.

REMOVE AND REPLACE ALL SWITCHES & RECEPTACLES IN EXISTING LOCATIONS, INCLUDING GFCI AS REQUIRED

MECHANICAL VENTILATION - EXISTING TO BE REPLACED w/ SIMILAR, BRAUN 6" VENTILATION FAN ON SENSOR CONTROLS

AND VENTED THROUGH THE ROOF

HVAC : INSTALL NEW BASE BOARD HEATERS PER PLANS. FURNISH ALL HEATERS W/ WALL MOUNTED THERMOSTATS, MODEL SPECIFICATION: CADET MODEL: 4F1000W, 48” BASEBOARD HEATER, 1000W, 4.2A, 240V

3 1 2 "

NATURAL VENTILATION REQUIREMENTS:

EACH RESTROOM FLOOR AREA: 95 SF | 4% FLOOR AREA: 3.8 SF

WINDOWS: 2

WINDOW EFFECTIVE OPEN AREA (3.125 SF/ WINDOW) : 6.25 SF

AREA REQUIRED: 3.8 SF | AREA PROVIDED: 6.25SF

MECH AND LOUNGE FLOOR AREA: 84 SF | 4% FLOOR AREA: 3.36 SF

WINDOWS: 2

WINDOW EFFECTIVE OPEN AREA (3.125 SF/ WINDOW) : 6.25 SF

AREA REQUIRED: 3.36 SF | AREA PROVIDED: 6.25 SF

9'-4" ± 1'-4" 9'-4"

18" MIN

21'-91 2"

'-9

1 2"

9'- 1"

9'-4" 9'-4"

TYPICAL EXTERIOR

NOTES:

EXISTING ROOF &

SOFFIT TO REMAIN.

REMOVE AND

REPLACE FASCIA

REMOVE AND

REPLACE ELEC

METERS

REDUCE PRECAST

CONCRETE WINDOW

SILL TO

ACCOMMODATE

NEW EXTERIOR

MATERIALS

WC-1

WC-2

SH-1SH-2

LAV-1

LAV-1

A-4.01

NORTH

DATE:

DESIGNED BY:

DRAWN BY:

REVIEWED BY:

SHEET NUMBER:

THE REPRODUCTION, COPYING OR

OTHER USE OF THIS DRAWING WITHOUT

WRITTEN CONSENT IS PROHIBITED.

© 2022 EDGEWATER RESOURCES, LLC.

ISSUED FOR:

DATE REVISION

PR

O

JE

C

T

TI

TL

E:

SH

EE

T

TI

TL

E:

518 Broad Street, Suite 200 Saint Joseph, MI 49085

P: 269.932.4502 edgewaterresources.com

PROJ NO.:

751/17185.JBB

DTMB PROJ. NO.

SCALE: 1/4" = 1'-0"1 PROPOSED SOUTH ELEVATION

SCALE: 1/4" = 1'-0"2 PROPOSED EAST ELEVATION

SCALE: 1/4" = 1'-0"3 PROPOSED NORTH ELEVATION

SCALE: 1/4" = 1'-0"4 PROPOSED WEST ELEVATION

FINISHES COLOR BOARD

QUARTZ EPOXY FLOOR AND

WALL BASE SYSTEM TO CLOSELY

MATCH "MAUVE MULTICOLOR"

EXTERIOR FINISHES

SS-1: SWANSTONE BEAD

BOARD WAINSCOT TO

36" AFF w/ TOP TRIM

PELLA WINDOWS 250 SERIES

WHITE VINYL INTERIOR AND

EXTERIOR OR EQUAL

TYPICAL EXTERIOR RENOVATION:

EXISTING ROOF TO REMAIN

NEW LP SMART SIDE FASCIA

BOARDS

NEW ALL VINYL WINDOWS IN

EXISTING OPENINGS

INSTALL NEW LP SMART SIDE,

6" EXPOSURE LAP SIDING, w/

4" CORNER, WINDOW AND

DOOR TRIM

NEW CONCRETE WALK TO

SLOPE

UP TO EXISTING FLOOR

LEVEL AT 1:12 MAX SLOPE

TYPICAL EXTERIOR RENOVATION:

8'- 2"

E

XI

ST

6'-

" E

XI

ST

6'-

EX

IS

T.

2'-8"

EXIST. O.H.

EXISTING VENTED

SOFFIT TO REMAIN.

CLEAN AND PAINT TO

MATCH WHITE LP

SIDING COLOR (TYP)

LP SMART SIDE LAP SIDING AND

TRIM SYSTEM PRE FINI. IN "SNOW

WHITE" STANDARD LP COLOR

PRE FINISHED FIBERGLASS

DOORS AND FRAMES TO MATCH

EXISTING BOATHOUSE GREEN

EXTERIOR ROOF SHINGLES

TO REMAIN

INTERIOR FINISHES

NO ROOM NAME DOOR SIZE

DOOR FRAME

NOTES

TYPE MATERI

AL FINISH TYPE MATE

RIAL FINISH

101 UNISEX RESTROOM #1 3'-0" x 6'-8" A F.GLASS PT 1 F.GLAS

S PT. GREEN TO MATCH EXIST.

BOATHOUSE

102 UNISEX RESTROOM #2 3'-0" x 6'-8" A F.GLASS PT 1 F.GLAS

S PT. GREEN TO MATCH EXIST.

BOATHOUSE

103 STAFF OFFICE 3'-0" x 6'-8" A F.GLASS PT 1 F.GLAS

S PT. GREEN TO MATCH EXIST.

BOATHOUSE

104 STAFF BREAK ROOM 3'-0" x 6'-8" A F.GLASS PT 1 F.GLAS

S PT. GREEN TO MATCH EXIST.

BOATHOUSE

DOOR SCHEDULE

WINDOW SCHEDULE

FINISH SCHEDULE

ELECTRICAL METER

LP BLOCK w/ 1 x 2 TRIM

AR

C

H

IT

EC

TU

R

AL

D

ET

AI

LS

EA

G

LE

H

AR

BO

R , M

I H

AR

BO

R U

PG

R

AD

ES

EA

GL

E

HA

RB

OR

S

TA

TE

H

AR

BO

R

A-4.01

CH

MMR

MMR

17-37

6/10/2022

AS NOTED

BID

TYPE B - HALF LITE TYPE 1

2" SEE

SCHEDULE

2"

2"

SE

E

SC

HE

DU

LE

FRAME TYPE

DOORS AND FRAMES

DOOR TYPE

ALL DOOR HARDWARE TO MEET ADA STANDARDS AND PER WRITTEN SPECIFICATION

MARK ROUGH OPENING TYPE MANUFACTURER MODEL NO. COLOR REMARKS

WIDTH HEIGHT VERIFY EXISTING OPENING DIMENSIONS

A 2'-6" 2'-6" CASEMENT PELLA 250 SERIES 2-6/2-6 WHITE STATIONARY - MASONRY INSTALLATION B 2'-6" 1'-3" AWNING PELLA 250 SERIES 2-6/1-3 WHITE OPERABLE - MASONRY INSTALLATION

TYPE A - FLUSH

SCALE: 1/4" = 1'-0"5 BUILDING AND WALL SECTION A-A

PNT-1: INTERIOR WALLS

SHERWIN WILLIAMS

# 9136 "LULLABY"

SWANSTONE SHOWER

SURROUND KIT

COLOR 168 "BABY'S BREATH"

MARK ROOM NAME FLOOR FINISH WALL BASE

WALL FINISH

CEILING FINISH CEILING

HEIGHT NOTES

NORTH SOUTH EAST WEST

**CEILING PAINT SW # 7005 FOR

ALL CEILINGS

101 UNISEX RESTROOM EPOXY EPOXY PNT-1 PNT-1 PNT-1 PNT-1/SS-1 PAINT EXISTING EXISTING REMOVE ALL LOOSE WALL, CEILING

& FLOOR PAINT, PATCH AND REPAIR

EXIST SURFACES PRIOR TO

PAINTING

102 MECHANICAL ROOM PAINT EXIST. NA PNT-1 PNT-1 PNT-1 PNT-1 PAINT EXISTING EXISTING 103 BOATER'S LOUNGE PAINT EXIST. VINYL PNT-1 PNT-1 PNT-1 PNT-1 PAINT EXISTING EXISTING 104 UNISEX RESTROOM EPOXY EPOXY PNT-1 PNT-1 PNT-1/SS-1 PNT-1 PAINT EXISTING EXISTING

EXISTING ROOF STRUCTURE TO

REMAIN

REMOVE AND REPLACE FASCIA

BOARDS w/ NEW LP SMART SIDE

SYSTEM

INSTALL NEW, ALL VINYL WINDOWS

IN EXISTING OPENINGS w/ 1 x 4 LP

SMART LUMBER TO SHIM AS REQ'D

INSTALL NEW TREATED 2 x 4 WOOD

FURRING, ANCHORED AND ADHERED

DIRECTLY TO THE EXTERIOR CMU

WALLS, AIR AND MOISTURE BARRIER,

LP SMART SIDE LAP SIDING PER

MFGR INSTRUCTIONS FOR MASONRY

ON ENTIRE BUILDING EXTERIOR

NEW CONCRETE WALK TO SLOPE

UP TO EXISTING FLOOR

LEVEL AT

REMOVE CONCRETE FLOOR AS

NEEDED TO RECESS SHOWER PAN

w/ MINIMUM SHOWER THRESHOLD

FOR BARRIER FREE SHOWER

EXISTING ROOF TO REMAIN

NEW LP SMART SIDE

FASCIA BOARDS

NEW ALL VINYL WINDOWS IN

EXISTING OPENINGS

NEW FIBERGLASS DOORS AND

FRAMES IN EXIST.

OPENINGS MATCH COLOR TO

EXISTING COAST GUARD

BOATHOUSE DOORS

INSTALL NEW LP SMART

SIDE, 6" EXPOSURE LAP

SIDING, w/ 4" CORNER, WINDOW

AND DOOR TRIM

NEW CONCRETE WALK TO

SLOPE UP TO EXISTING FLR

SCALE: 1/2" = 1'-0"7 SIDING / WINDOW DETAIL

INSTALL NEW 5 4 X 4 LP SMART TRIM

INSTALL NEW LP SMART SIDE 1x FASCIA

INSTALL NEW, ALL VINYL WINDOWS IN EXISTING

OPENINGS W/ 1 X 4 LP SMART LUMBER TO SHIM AS

REQ'D AND TYP TRIM W/ 4" X 54 AND SMART TRIM.

INSTALL LP SILL, SLOPE TO DRAIN

ALTERNATE INSTALL WHITE BREAK METAL SILL OVER

EXIST. CMU SILL

TR. 2 x 4 FURRING ANCHORED AND ADHERED TO

EXISTING CONCRETE BLOCK @ 16" O.C. & PER LP

SMART SIDE MASONRY INSTALL INSTRUCTIONS

AIR AND MOISTURE BARRIER

LP SMART SIDE 6" LAP SIDING OVER A & M BARRIER

INSTALLED PER MFGR INSTRUCTIONS

4 x 4 CORNER BOARD TRIM

INSTALL FULL LENGTH CONTINUOUS HINGE ON ALL DOORS

TOILET ROOM ACCESSORIES

PROVIDED AND INSTALLED BY

OWNER TO COMPLY w/ BARRIER

FREE HEIGHT REQUIREMENTS

SCALE: 1/4" = 1'-0"8 INTERIOR ELEVATION

NEW 2 x 4 WD STUDS @ 16" O.C w/ 5/8" GYP BOARD ON DRY SIDE.

INSTALL VAPOR BARRIER AND

CEMENTITIOUS BACKER BOARD AT

SHOWER SIDE.

PAINTED EXISTING CMU

AND GYP BD WALLS

SWANSTONE OR EQUAL WAINSCOT

INSTALLED DIRECTLY ON NEW AND

EXISTING WALLS AT 36" AFF

SWANSTONE OR EQUAL BARRIER

FREE SHOWER WALL KIT w/

GRAB BARS, HAND HELD CONTROL

WAND AND FOLDING SEAT

3'- 0"

6'- 0"

S

HO

W

ER

W

AL

L K

IT

EXISTING CONDITIONS

PROPOSED EXTERIOR RENOVATION

SCALE:

PROVIDE NEW SIGNAGE w/

INTERNATIONAL SYMBOL OF

ACCESSIBILITY AT ALL

RESTROOMS. MATCH EXISTING

DNR SIGN STYLE AND COLOR

File details come from the government source that posted it. Updated .